Purnendu K. Dasgupta, PhD - Publications

Affiliations: 
1981-2006 Chemistry & Biochemistry Texas Tech University, Lubbock, TX 
 2007- Chemistry & Biochemistry University of Texas at Arlington, Arlington, TX, United States 
Area:
Analytical Chemistry, Environmental Chemistry, Instrumentation
Website:
https://www.uta.edu/chemistry/faculty/sandy_dasgupta.php

331 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2020 Liu H, Patron A, Wang Y, Dasgupta PK. Exploiting adduct formation through an auxiliary spray in liquid chromatography-electrospray ionization mass spectrometry to improve charge-carrier identification. Journal of Chromatography. A. 1632: 461601. PMID 33069953 DOI: 10.1016/j.chroma.2020.461601  0.701
2020 Maleki F, Dasgupta PK. Moldable Strong Cation Exchange Polymer and Microchannel Fabrication. Analytical Chemistry. PMID 32862638 DOI: 10.1021/Acs.Analchem.0C02754  0.312
2020 Chouhan B, Shelor CP, Huang W, Chen Y, Dasgupta PK. Nanovolume Gas-Free Hydroxide Eluent Generator for Open Tubular Ion Chromatography. Analytical Chemistry. PMID 32138510 DOI: 10.1021/Acs.Analchem.0C00505  0.589
2019 Qin C, Dasgupta PK. Time of Sight Liquid Flow Measurements in the Low Nanoliters per Minute Scale. Analytical Chemistry. PMID 31618579 DOI: 10.1021/Acs.Analchem.9B02756  0.332
2019 Dasgupta PK, Maleki F. Ion exchange membranes in ion chromatography and related applications. Talanta. 204: 89-137. PMID 31357379 DOI: 10.1016/J.Talanta.2019.05.077  0.369
2019 Sricharoen P, Limchoowong N, Shelor CP, Dasgupta PK. Carbonic Acid Eluent Ion Chromatography. Analytical Chemistry. PMID 30719920 DOI: 10.1021/Acs.Analchem.8B05627  0.36
2019 Chouhan B, Dasgupta PK. Direct Photothermal Measurement of Optical Absorption in a Flow System. Analytical Chemistry. PMID 30649852 DOI: 10.1021/Acs.Analchem.8B05091  0.34
2018 Huang W, Chouhan B, Dasgupta PK. Admittance and Conductance Detection in the Capillary Scale. Analytical Chemistry. PMID 30465432 DOI: 10.1021/Acs.Analchem.8B04561  0.346
2018 Huang W, Seetasang S, Dasgupta PK. Characterization of ion exchange functionalized cyclic olefin polymer open tubular columns. Analytica Chimica Acta. 1036: 187-194. PMID 30253831 DOI: 10.1016/J.Aca.2018.06.063  0.342
2018 Huang W, Pohl CA, Dasgupta PK. Ion exchange column capacities. Predicting retention behavior of open tubular columns coated with the same phase. Journal of Chromatography. A. PMID 29625771 DOI: 10.1016/J.Chroma.2018.03.056  0.316
2018 Mishra SK, Chattopadhyay B, Kadjo AF, Dasgupta PK. Continuous measurement of elemental composition of ambient aerosol by induction-coupled plasma mass spectrometry. Talanta. 177: 197-202. PMID 29108576 DOI: 10.1016/J.Talanta.2017.07.064  0.357
2017 Dasgupta PK, Shelor CP, Kadjo AF, Kraiczek KG. Flow-Cell-induced Dispersion in Flow-through Absorbance Detection Systems. True Column Effluent Peak Variance. Analytical Chemistry. PMID 29281880 DOI: 10.1021/Acs.Analchem.7B04248  0.359
2017 Qin C, Stamos BN, Dasgupta PK. In-line Shunt Flow Monitor for Hydrocephalus. Analytical Chemistry. PMID 28686013 DOI: 10.1021/Acs.Analchem.7B02034  0.3
2017 Stamos BN, Dasgupta PK, Ohira SI. ADMITTANCE SCANNING FOR WHOLE COLUMN DETECTION. Analytical Chemistry. PMID 28570810 DOI: 10.1021/Acs.Analchem.7B01412  0.358
2017 Shelor CP, Dasgupta PK. Automated programmable pressurized carbonic acid eluent ion exclusion chromatography of organic acids. Journal of Chromatography. A. PMID 28549716 DOI: 10.1016/J.Chroma.2017.05.036  0.354
2017 Kadjo AF, Liao H, Dasgupta PK, Kraiczek KG. Width Based Characterization of Chromatographic Peaks. Beyond Height and Area. Analytical Chemistry. PMID 28244321 DOI: 10.1021/Acs.Analchem.6B04858  0.33
2017 Kadjo AF, Dasgupta PK, Su J, Liu S, Kraiczek KG. Width Based Quantitation of Chromatographic Peaks. Principles and Principal Characteristics. Analytical Chemistry. PMID 28244311 DOI: 10.1021/Acs.Analchem.6B04857  0.308
2016 Shelor CP, Dasgupta PK, Liao H. Conductometric Gradient Ion Exclusion Chromatography for Volatile Fatty Acids. Analytical Chemistry. 88: 12323-12329. PMID 28193054 DOI: 10.1021/Acs.Analchem.6B03519  0.349
2016 Huang W, Seetasang S, Azizi M, Dasgupta PK. Functionalized Cycloolefin Polymer Capillaries for Open Tubular Ion Chromatography. Analytical Chemistry. 88: 12013-12020. PMID 28193028 DOI: 10.1021/Acs.Analchem.6B03669  0.339
2016 Huang W, Dasgupta PK. Electrodialytic Capillary Suppressor for Open Tubular Ion Chromatography. Analytical Chemistry. 88: 12021-12027. PMID 28193023 DOI: 10.1021/Acs.Analchem.6B03667  0.326
2016 Kadjo AF, Stamos BN, Shelor CP, Berg JM, Blount BC, Dasgupta PK. EVALUATION OF AMOUNT OF BLOOD IN DRY BLOOD SPOTS. RING DISK ELECTRODE CONDUCTOMETRY. Analytical Chemistry. PMID 27226021 DOI: 10.1021/Acs.Analchem.6B01280  0.305
2016 Liao H, Shelor CP, Dasgupta PK. Water ICE. Ion Exclusion Chromatography of Very Weak Acids with a Pure Water Eluent. Analytical Chemistry. PMID 27075932 DOI: 10.1021/Acs.Analchem.6B00902  0.361
2016 Wahab MF, Dasgupta PK, Kadjo AF, Armstrong DW. Sampling frequency, response times and embedded signal filtration in fast, high efficiency liquid chromatography: A tutorial. Analytica Chimica Acta. 907: 31-44. PMID 26803000 DOI: 10.1016/J.Aca.2015.11.043  0.311
2016 Liu H, Lam L, Chi B, Kadjo AF, Dasgupta PK. Transient Ion-Pair Separations for Electrospray Mass Spectrometry. Analytical Chemistry. 88: 2059-64. PMID 26765166 DOI: 10.1021/Acs.Analchem.5B03202  0.726
2015 Ohira SI, Nakamura K, Shelor CP, Dasgupta PK, Toda K. Simultaneous Electrodialytic Preconcentration and Speciation of Chromium(III) and Chromium(VI). Analytical Chemistry. PMID 26507203 DOI: 10.1021/Acs.Analchem.5B03464  0.306
2015 Liao H, Kadjo AF, Dasgupta PK. Concurrent High-Sensitivity Conductometric Detection of Volatile Weak Acids in a Suppressed Anion Chromatography System. Analytical Chemistry. 87: 8342-6. PMID 26204389 DOI: 10.1021/Acs.Analchem.5B01523  0.397
2015 Nakamura Y, Maeda S, Nishiyama H, Ohira SI, Dasgupta PK, Toda K. Micro Ion Extractor for Single Drop Whole Blood Analysis. Analytical Chemistry. PMID 26084326 DOI: 10.1021/Acs.Analchem.5B01681  0.344
2015 Shelor CP, Liao H, Kadjo AF, Dasgupta PK. Enigmatic ion-exchange behavior of myo-inositol phosphates. Analytical Chemistry. 87: 4851-5. PMID 25865157 DOI: 10.1021/Acs.Analchem.5B00351  0.33
2015 Li YH, Shelor CP, Dasgupta PK. Nonlinear absorbance amplification using a diffuse reflectance cell: total organic carbon monitoring at 214 nm. Analytical Chemistry. 87: 1111-7. PMID 25514042 DOI: 10.1021/Ac503810Z  0.308
2015 Ohira S, Hiroyama Y, Nakamura K, Koda T, Dasgupta PK, Toda K. Electrodialytic matrix isolation for metal cations. Talanta. 132: 228-33. PMID 25476302 DOI: 10.1016/J.Talanta.2014.09.013  0.326
2015 Liao H, Dasgupta PK, Srinivasan K, Liu Y. Mixing characteristics of mixers in flow analysis. Application to two-dimensional detection in ion chromatography. Analytical Chemistry. 87: 793-800. PMID 25426864 DOI: 10.1021/Ac5038076  0.402
2014 Ohira SI, Kuhara K, Shigetomi A, Yamasaki T, Kodama Y, Dasgupta PK, Toda K. On-line electrodialytic matrix isolation for chromatographic determination of organic acids in wine. Journal of Chromatography. A. 1372: 18-24. PMID 25465003 DOI: 10.1016/J.Chroma.2014.10.077  0.366
2014 Liu H, Lam L, Yan L, Chi B, Dasgupta PK. Expanding the linear dynamic range for quantitative liquid chromatography-high resolution mass spectrometry utilizing natural isotopologue signals. Analytica Chimica Acta. 850: 65-70. PMID 25441161 DOI: 10.1016/J.Aca.2014.07.039  0.721
2014 Yang B, Zhang M, Kanyanee T, Stamos BN, Dasgupta PK. An open tubular ion chromatograph. Analytical Chemistry. 86: 11554-61. PMID 25394230 DOI: 10.1021/Ac503249T  0.354
2014 Zhang M, Stamos BN, Dasgupta PK. Admittance detector for high impedance systems: design and applications. Analytical Chemistry. 86: 11547-53. PMID 25354912 DOI: 10.1021/Ac503247G  0.354
2014 Shen H, Dasgupta PK. Electrochemical arsine generators for arsenic determination. Analytical Chemistry. 86: 7705-11. PMID 25034004 DOI: 10.1021/Ac501636U  0.367
2014 Shelor CP, Dasgupta PK, Aubrey A, Davila AF, Lee MC, McKay CP, Liu Y, Noell AC. What can in situ ion chromatography offer for Mars exploration? Astrobiology. 14: 577-88. PMID 24963874 DOI: 10.1089/Ast.2013.1131  0.357
2014 Ma J, Sengupta MK, Yuan D, Dasgupta PK. Speciation and detection of arsenic in aqueous samples: a review of recent progress in non-atomic spectrometric methods. Analytica Chimica Acta. 831: 1-23. PMID 24861967 DOI: 10.1016/J.Aca.2014.04.029  0.307
2014 Toda K, Yunoki S, Yanaga A, Takeuchi M, Ohira S, Dasgupta PK. Formaldehyde content of atmospheric aerosol. Environmental Science & Technology. 48: 6636-43. PMID 24857706 DOI: 10.1021/Es500590E  0.331
2014 Macka M, Piasecki T, Dasgupta PK. Light-emitting diodes for analytical chemistry. Annual Review of Analytical Chemistry (Palo Alto, Calif.). 7: 183-207. PMID 24818811 DOI: 10.1146/Annurev-Anchem-071213-020059  0.313
2014 Dasgupta PK, Bhawal RP, Li YH, Ibraguimov A. Cavity-enhanced absorption measurements across broad absorbance and reflectivity ranges. Analytical Chemistry. 86: 3727-34. PMID 24646361 DOI: 10.1021/Ac404251W  0.309
2013 Zhang M, Yang B, Dasgupta PK. Polymethylmethacrylate open tubular ion exchange columns: nondestructive measurement of very small ion exchange capacities. Analytical Chemistry. 85: 7994-8000. PMID 23875750 DOI: 10.1021/Ac4018583  0.333
2013 Liao H, Shelor CP, Chen Y, Sabaa-Srur AU, Smith RE, Dasgupta PK. Anion composition of açaı́ extracts. Journal of Agricultural and Food Chemistry. 61: 5928-35. PMID 23772604 DOI: 10.1021/Jf4014185  0.55
2013 Tian Y, Dasgupta PK, Mahon SB, Ma J, Brenner M, Wang JH, Boss GR. A disposable blood cyanide sensor. Analytica Chimica Acta. 768: 129-35. PMID 23473259 DOI: 10.1016/J.Aca.2013.01.029  0.326
2012 Mori M, Chen Y, Ohira S, Dasgupta PK. Characterization of a constant current charge detector. Talanta. 102: 44-52. PMID 23182573 DOI: 10.1016/J.Talanta.2012.07.058  0.56
2012 Puanngam M, Dasgupta PK, Unob F. Automated on-line preconcentration of trace aqueous mercury with gold trap focusing for cold vapor atomic absorption spectrometry. Talanta. 99: 1040-5. PMID 22967660 DOI: 10.1016/J.Talanta.2012.05.055  0.388
2012 Ohira S, Goto K, Toda K, Dasgupta PK. A capacitance sensor for water: trace moisture measurement in gases and organic solvents. Analytical Chemistry. 84: 8891-7. PMID 22962839 DOI: 10.1021/Ac3024069  0.355
2012 Ma J, Dasgupta PK, Zelder FH, Boss GR. Cobinamide chemistries for photometric cyanide determination. A merging zone liquid core waveguide cyanide analyzer using cyanoaquacobinamide. Analytica Chimica Acta. 736: 78-84. PMID 22769008 DOI: 10.1016/J.Aca.2012.05.028  0.309
2012 Ohira S, Kuhara K, Kudo M, Kodama Y, Dasgupta PK, Toda K. Electrodialytic ion isolation for matrix removal. Analytical Chemistry. 84: 5421-6. PMID 22642426 DOI: 10.1021/Ac300982K  0.34
2012 Chen Y, Edwards BL, Dasgupta PK, Srinivasan K. pH- and concentration-programmable electrodialytic buffer generator. Analytical Chemistry. 84: 59-66. PMID 22148285 DOI: 10.1021/Ac2023734  0.556
2012 Chen Y, Srinivasan K, Dasgupta PK. Electrodialytic membrane suppressors for ion chromatography make programmable buffer generators. Analytical Chemistry. 84: 67-75. PMID 22103670 DOI: 10.1021/Ac2023712  0.563
2012 Wang X, Liu L, Guo G, Wang W, Liu S, Pu Q, Dasgupta PK. Resolving DNA in free solution Trac Trends in Analytical Chemistry. 35: 122-134. DOI: 10.1016/J.Trac.2012.01.005  0.589
2011 Liu H, Lam L, Dasgupta PK. Expanding the linear dynamic range for multiple reaction monitoring in quantitative liquid chromatography-tandem mass spectrometry utilizing natural isotopologue transitions. Talanta. 87: 307-10. PMID 22099684 DOI: 10.1016/J.Talanta.2011.09.063  0.712
2011 Sengupta MK, Dasgupta PK. Oxidation state-differentiated measurement of aqueous inorganic arsenic by continuous flow electrochemical arsine generation coupled to gas-phase chemiluminescence detection. Analytical Chemistry. 83: 9378-83. PMID 22035322 DOI: 10.1021/Ac201972M  0.365
2011 Huang X, Foss FW, Dasgupta PK. Multilayer chitosan-based open tubular capillary anion exchange column with integrated monolithic capillary suppressor Analytica Chimica Acta. 707: 210-217. PMID 22027141 DOI: 10.1016/J.Aca.2011.09.028  0.354
2011 Ma J, Ohira S, Mishra SK, Puanngam M, Dasgupta PK, Mahon SB, Brenner M, Blackledge W, Boss GR. Rapid point of care analyzer for the measurement of cyanide in blood. Analytical Chemistry. 83: 4319-24. PMID 21553921 DOI: 10.1021/Ac200768T  0.338
2011 Huang X, Dasgupta PK. Controlled porosity monolithic material as permselective ion exchange membranes. Analytica Chimica Acta. 689: 155-9. PMID 21397069 DOI: 10.1016/J.Aca.2011.01.020  0.314
2011 He C, Lu JJ, Jia Z, Wang W, Wang X, Dasgupta PK, Liu S. Flow batteries for microfluidic networks: configuring an electroosmotic pump for nonterminal positions. Analytical Chemistry. 83: 2430-3. PMID 21375230 DOI: 10.1021/Ac200156S  0.631
2011 Ma J, Dasgupta PK, Yang B. Rapid nondestructive spectrometric measurement of temperature-dependent gas-liquid solubility equilibria. Analytical Chemistry. 83: 1157-61. PMID 21192720 DOI: 10.1021/Ac102947J  0.323
2011 Chen Y, Mori M, Pastusek AC, Schug KA, Dasgupta PK. On-line electrodialytic salt removal in electrospray ionization mass spectrometry of proteins. Analytical Chemistry. 83: 1015-21. PMID 21162592 DOI: 10.1021/Ac102809C  0.587
2011 Yang T, Chen ML, Hu XW, Wang ZW, Wang JH, Dasgupta PK. Thiolated eggshell membranes sorb and speciate inorganic selenium. The Analyst. 136: 83-9. PMID 20877887 DOI: 10.1039/C0An00480D  0.329
2010 Dasgupta PK, Chen Y, Serrano CA, Guiochon G, Liu H, Fairchild JN, Shalliker RA. Black box linearization for greater linear dynamic range: the effect of power transforms on the representation of data. Analytical Chemistry. 82: 10143-50. PMID 21105736 DOI: 10.1021/Ac102242T  0.737
2010 Toda K, Koga T, Tanaka T, Ohira S, Berg JM, Dasgupta PK. Miniature open channel scrubbers for gas collection. Talanta. 82: 1870-5. PMID 20875590 DOI: 10.1016/J.Talanta.2010.08.001  0.384
2010 Ma J, Dasgupta PK. Recent developments in cyanide detection: a review. Analytica Chimica Acta. 673: 117-25. PMID 20599024 DOI: 10.1016/J.Aca.2010.05.042  0.346
2010 Ma J, Dasgupta PK, Blackledge W, Boss GR. Cobinamide-based cyanide analysis by multiwavelength spectrometry in a liquid core waveguide. Analytical Chemistry. 82: 6244-50. PMID 20560532 DOI: 10.1021/Ac101158D  0.406
2010 Ganranoo L, Mishra SK, Azad AK, Shigihara A, Dasgupta PK, Breitbach ZS, Armstrong DW, Grudpan K, Rappenglueck B. Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry. Analytical Chemistry. 82: 5838-43. PMID 20518471 DOI: 10.1021/Ac101015Y  0.32
2010 Mishra SK, Dasgupta PK. Electrodialytic reagent introduction in flow systems. Analytical Chemistry. 82: 3981-4. PMID 20423104 DOI: 10.1021/Ac100882A  0.388
2010 Sengupta MK, Sawalha MF, Ohira S, Idowu AD, Dasgupta PK. Green analyzer for the measurement of total arsenic in drinking water: electrochemical reduction of arsenate to arsine and gas phase chemiluminescence with ozone. Analytical Chemistry. 82: 3467-73. PMID 20380446 DOI: 10.1021/Ac100604Y  0.343
2010 Puanngam M, Ohira S, Unob F, Wang JH, Dasgupta PK. A cold plasma dielectric barrier discharge atomic emission detector for atmospheric mercury. Talanta. 81: 1109-15. PMID 20298901 DOI: 10.1016/J.Talanta.2010.02.005  0.315
2010 Berg JM, James DL, Berg CF, Toda K, Dasgupta PK. Gas collection efficiency of annular denuders: a spreadsheet-based calculator. Analytica Chimica Acta. 664: 56-61. PMID 20226932 DOI: 10.1016/J.Aca.2010.02.006  0.315
2010 Lu C, Rashinkar SM, Dasgupta PK. Semicontinuous automated measurement of organic carbon in atmospheric aerosol samples. Analytical Chemistry. 82: 1334-41. PMID 20092351 DOI: 10.1021/Ac9023582  0.327
2010 Yang B, Chen Y, Mori M, Ohira S, Azad AK, Dasgupta PK, Srinivasan K. Charge detector for the measurement of ionic solutes. Analytical Chemistry. 82: 951-8. PMID 20055448 DOI: 10.1021/Ac9021902  0.55
2010 Wang X, Veerappan V, Cheng C, Jiang X, Allen RD, Dasgupta PK, Liu S. Free solution hydrodynamic separation of DNA fragments from 75 to 106,000 base pairs in a single run. Journal of the American Chemical Society. 132: 40-1. PMID 20014789 DOI: 10.1021/Ja909233N  0.599
2010 Sengupta MK, Hossain ZA, Ohira S, Dasgupta PK. A simple inexpensive gas phase chemiluminescence analyzer for measuring trace levels of arsenic in drinking water. Environmental Pollution (Barking, Essex : 1987). 158: 252-7. PMID 19651464 DOI: 10.1016/J.Envpol.2009.07.014  0.352
2009 Sengupta MK, Dasgupta PK. An automated hydride generation interface to ICPMS for measuring total arsenic in environmental samples. Analytical Chemistry. 81: 9737-43. PMID 19891455 DOI: 10.1021/Ac9020243  0.361
2009 Tian K, Dasgupta PK. A permeable membrane capacitance sensor for ionogenic gases Application to the measurement of total organic carbon. Analytica Chimica Acta. 652: 245-50. PMID 19786188 DOI: 10.1016/J.Aca.2009.04.028  0.318
2009 Wang X, Cheng C, Wang S, Zhao M, Dasgupta PK, Liu S. Nanocapillaries for open tubular chromatographic separations of proteins in femtoliter to picoliter samples. Analytical Chemistry. 81: 7428-35. PMID 19663450 DOI: 10.1021/Ac901265T  0.629
2009 Yang B, Zhang F, Liang X, Dasgupta PK, Liu S. Ion exchange resin bead decoupled high-pressure electroosmotic pump. Analytical Chemistry. 81: 5102-6. PMID 19449862 DOI: 10.1021/Ac900570S  0.643
2009 Ohira S, Dasgupta PK, Schug KA. Fiber optic sensor for simultaneous determination of atmospheric nitrogen dioxide, ozone, and relative humidity. Analytical Chemistry. 81: 4183-91. PMID 19402646 DOI: 10.1021/Ac801756Z  0.306
2009 Yang B, Zhang F, Liang X, Dasgupta PK. A multifunctional dual membrane electrodialytic eluent generator for capillary ion chromatography. Journal of Chromatography. A. 1216: 2412-6. PMID 19178910 DOI: 10.1016/J.Chroma.2009.01.025  0.355
2009 Ohira S, Wanigasekara E, Rudkevich DM, Dasgupta PK. Sensing parts per million levels of gaseous NO2 by a optical fiber transducer based on calix[4]arenes. Talanta. 77: 1814-20. PMID 19159804 DOI: 10.1016/J.Talanta.2008.10.024  0.317
2009 Chen XW, Zou AM, Chen ML, Wang JH, Dasgupta PK. Live HeLa cells preconcentrate and differentiate inorganic arsenic species. Analytical Chemistry. 81: 1291-6. PMID 19128047 DOI: 10.1021/Ac802475B  0.307
2009 Ohira S, Kirk AB, Dasgupta PK. Automated measurement of urinary creatinine by multichannel kinetic spectrophotometry. Analytical Biochemistry. 384: 238-44. PMID 18977332 DOI: 10.1016/J.Ab.2008.10.015  0.36
2008 Sawalha MF, Sengupta MK, Ohira S, Idowu AD, Gill TE, Rojo L, Barnes M, Dasgupta PK. Measurement of soil/dust arsenic by gas phase chemiluminescence. Talanta. 77: 372-9. PMID 18804648 DOI: 10.1016/J.Talanta.2008.06.037  0.353
2008 Kubán P, Pelcová P, Kubán V, Klakurková L, Dasgupta PK. Gravity-flow open tubular cation chromatography. Journal of Separation Science. 31: 2745-53. PMID 18666181 DOI: 10.1002/Jssc.200800305  0.706
2008 Takeuchi M, Li Q, Yang B, Dasgupta PK, Wilde VE. Use of a capacitance measurement device for surrogate noncontact conductance measurement. Talanta. 76: 617-20. PMID 18585329 DOI: 10.1016/J.Talanta.2008.04.001  0.343
2008 Li Q, Dasgupta PK, Temkins HK. Airborne bacterial spore counts by terbium-enhanced luminescence detection: pitfalls and real values. Environmental Science & Technology. 42: 2799-804. PMID 18497126 DOI: 10.1021/Es702472T  0.345
2008 Li J, Li Q, Dyke JV, Dasgupta PK. Atmospheric ozone measurement with an inexpensive and fully automated porous tube collector-colorimeter. Talanta. 74: 958-64. PMID 18371734 DOI: 10.1016/J.Talanta.2007.08.002  0.336
2008 Dasgupta PK, Liu Y, Dyke JV. Iodine nutrition: iodine content of iodized salt in the United States. Environmental Science & Technology. 42: 1315-23. PMID 18351111 DOI: 10.1021/Es0719071  0.31
2008 Eom IY, Li Q, Li J, Dasgupta PK. Robust hybrid flow analyzer for formaldehyde. Environmental Science & Technology. 42: 1221-6. PMID 18351096 DOI: 10.1021/Es071472H  0.33
2008 Yang B, Takeuchi M, Dasgupta PK. On-line gas-free electrodialytic eluent generator for capillary ion chromatography. Analytical Chemistry. 80: 40-7. PMID 18062705 DOI: 10.1021/Ac701889X  0.357
2008 Toda K, Dasgupta PK. New applications of chemiluminescence for selective gas analysis Chemical Engineering Communications. 195: 82-97. DOI: 10.1080/00986440701569150  0.335
2008 Toda K, Dasgupta PK. Chapter 22 Environmental Applications: Atmospheric Trace Gas Analyses Comprehensive Analytical Chemistry. 54: 639-683. DOI: 10.1016/S0166-526X(08)00622-3  0.36
2008 Song G, Villanueva-Fierro I, Ohira SI, Mishra S, Bailiff H, Savage CR, Dasgupta PK. Capillary scale liquid core waveguide based fluorescence detectors for liquid chromatography and flow analysis Talanta. 77: 901-908. DOI: 10.1016/J.Talanta.2008.07.047  0.343
2007 Mornane P, van den Haak J, Cardwell TJ, Cattrall RW, Dasgupta PK, Kolev SD. Thin layer distillation for matrix isolation in flow analysis. Talanta. 72: 741-6. PMID 19071680 DOI: 10.1016/J.Talanta.2006.12.002  0.349
2007 Mishra SK, Dasgupta PK. Capillary scale light emitting diode based multi-reflection absorbance detector. Analytica Chimica Acta. 605: 166-74. PMID 18036380 DOI: 10.1016/J.Aca.2007.10.030  0.327
2007 Idowu AD, Dasgupta PK. Liquid chromatographic arsenic speciation with gas-phase chemiluminescence detection. Analytical Chemistry. 79: 9197-204. PMID 17949013 DOI: 10.1021/Ac701683H  0.364
2007 Soukup-Hein RJ, Remsburg JW, Dasgupta PK, Armstrong DW. A general, positive ion mode ESI-MS approach for the analysis of singly charged inorganic and organic anions using a dicationic reagent. Analytical Chemistry. 79: 7346-52. PMID 17722882 DOI: 10.1021/Ac071102B  0.337
2007 Takeuchi M, Dasgupta PK, Dyke JV, Srinivasan K. Postcolumn concentration in liquid chromatography. On-line eluent evaporation and analyte postconcentration in ion chromatography. Analytical Chemistry. 79: 5690-7. PMID 17608451 DOI: 10.1021/Ac0703799  0.399
2007 Ohira S, Li J, Lonneman WA, Dasgupta PK, Toda K. Can breath isoprene be measured by ozone chemiluminescence? Analytical Chemistry. 79: 2641-9. PMID 17326613 DOI: 10.1021/Ac062334Y  0.374
2007 Dyke JV, Ito K, Obitsu T, Hisamatsu Y, Dasgupta PK, Blount BC. Perchlorate in dairy milk. Comparison of Japan versus the United States Environmental Science and Technology. 41: 88-92. PMID 17265931 DOI: 10.1021/Es061429E  0.725
2007 Arnold JR, Hartsell BE, Luke WT, Rahmat Ullah SM, Dasgupta PK, Greg Huey L, Tate P. Field test of four methods for gas-phase ambient nitric acid Atmospheric Environment. 41: 4210-4226. DOI: 10.1016/J.Atmosenv.2006.07.058  0.361
2006 Eom IY, Dasgupta PK. Frequency-selective absorbance detection: Refractive index and turbidity compensation with dual-wavelength measurement. Talanta. 69: 906-13. PMID 18970656 DOI: 10.1016/J.Talanta.2005.11.033  0.326
2006 Choengchan N, Mantim T, Wilairat P, Dasgupta PK, Motomizu S, Nacapricha D. A membraneless gas diffusion unit: Design and its application to determination of ethanol in liquors by spectrophotometric flow injection Analytica Chimica Acta. 579: 33-37. PMID 17723724 DOI: 10.1016/J.Aca.2006.07.018  0.302
2006 Martinelango PK, Tian K, Dasgupta PK. Perchlorate in seawater: bioconcentration of iodide and perchlorate by various seaweed species. Analytica Chimica Acta. 567: 100-7. PMID 17723385 DOI: 10.1016/J.Aca.2006.02.015  0.306
2006 Martinelango PK, Gümüş G, Dasgupta PK. Matrix interference free determination of perchlorate in urine by ion association-ion chromatography-mass spectrometry. Analytica Chimica Acta. 567: 79-86. PMID 17723382 DOI: 10.1016/J.Aca.2006.02.022  0.369
2006 Dyke JV, Kirk AB, Martinelango PK, Dasgupta PK. Sample processing method for the determination of perchlorate in milk. Analytica Chimica Acta. 567: 73-8. PMID 17723381 DOI: 10.1016/J.Aca.2006.02.024  0.349
2006 Toda K, Li J, Dasgupta PK. Measurement of ammonia in human breath with a liquid-film conductivity sensor. Analytical Chemistry. 78: 7284-7291. PMID 17037934 DOI: 10.1021/Ac060965M  0.307
2006 Idowu AD, Dasgupta PK, Genfa Z, Toda K, Garbarino JR. A gas-phase chemiluminescence-based analyzer for waterborne arsenic. Analytical Chemistry. 78: 7088-97. PMID 17037907 DOI: 10.1021/Ac061439Y  0.33
2006 Kanyanee T, Borst WL, Jakmunee J, Grudpan K, Li J, Dasgupta PK. Soap bubbles in analytical chemistry. Conductometric determination of sub-parts per million levels of sulfur dioxide with a soap bubble. Analytical Chemistry. 78: 2786-93. PMID 16615794 DOI: 10.1021/Ac052198H  0.329
2006 Amornthammarong N, Jakmunee J, Li J, Dasgupta PK. Hybrid fluorometric flow analyzer for ammonia. Analytical Chemistry. 78: 1890-1896. PMID 16536425 DOI: 10.1021/Ac051950B  0.382
2006 Ullah SM, Takeuchi M, Dasgupta PK. Versatile gas/particle ion chromatograph. Environmental Science & Technology. 40: 962-8. PMID 16509343 DOI: 10.1021/Es051722Z  0.385
2006 Grover BD, Carter CB, Kleinman MA, Richards JS, Eatough NL, Eatough DJ, Dasgupta PK, Al-Horr R, Ullah SMR. Monitoring and Source Apportionment of Fine Particulate Matter at Lindon, Utah Aerosol Science and Technology. 40: 941-951. DOI: 10.1080/02786820600815424  0.319
2005 Takayanagi T, Dasgupta PK. A chemiluminescence-based continuous flow aqueous ozone analyzer using photoactivated chromotropic acid. Talanta. 66: 823-30. PMID 18970059 DOI: 10.1016/J.Talanta.2004.11.036  0.353
2005 Tian K, Cañas JE, Dasgupta PK, Anderson TA. Preconcentration/preelution ion chromatography for the determination of perchlorate in complex samples. Talanta. 65: 750-5. PMID 18969863 DOI: 10.1016/J.Talanta.2004.08.001  0.331
2005 Takeuchi M, Ullah SM, Dasgupta PK, Collins DR, Williams A. Continuous collection of soluble atmospheric particles with a wetted hydrophilic filter. Analytical Chemistry. 77: 8031-40. PMID 16351153 DOI: 10.1021/Ac051539O  0.309
2005 Martinelango PK, Anderson JL, Dasgupta PK, Armstrong DW, Al-Horr RS, Slingsby RW. Gas-phase ion association provides increased selectivity and sensitivity for measuring perchlorate by mass spectrometry. Analytical Chemistry. 77: 4829-35. PMID 16053295 DOI: 10.1021/Ac050479J  0.356
2005 Toda K, Ohba T, Takaki M, Karthikeyan S, Hirata S, Dasgupta PK. Speciation-Capable Field Instrument for the Measurement of Arsenite and Arsenate in Water Analytical Chemistry. 77: 4765-4773. PMID 16053287 DOI: 10.1021/Ac050193E  0.369
2005 Dasgupta PK, Li J, Zhang G, Luke WT, McClenny WA, Stutz J, Fried A. Summertime ambient formaldehyde in five U.S. metropolitan areas: Nashville, Atlanta, Houston, Philadelphia, and Tampa. Environmental Science & Technology. 39: 4767-83. PMID 16053074 DOI: 10.1021/Es048327D  0.701
2005 Dasgupta PK, Martinelango PK, Jackson WA, Anderson TA, Tian K, Tock RW, Rajagopalan S. The origin of naturally occurring perchlorate: The role of atmospheric processes Environmental Science and Technology. 39: 1569-1575. PMID 15819211 DOI: 10.1021/Es048612X  0.321
2005 Ullah SMR, Williams A, Dasgupta PK. Automated low-pressure carbonate eluent ion chromatography system with postsuppressor carbon dioxide removal for the analysis of atmospheric gases and particles Aerosol Science and Technology. 39: 1072-1084. DOI: 10.1080/02786820500421554  0.327
2005 Teshima N, Li J, Toda K, Dasgupta PK. Determination of acetone in breath Analytica Chimica Acta. 535: 189-199. DOI: 10.1016/J.Aca.2004.12.018  0.404
2005 Li J, Dasgupta PK, Luke W. Measurement of gaseous and aqueous trace formaldehyde Analytica Chimica Acta. 531: 51-68. DOI: 10.1016/J.Aca.2004.09.087  0.325
2004 Tanaka H, Tachibana T, Oda R, Dasgupta PK. Determination of acid dissociation constants based on continuous titration by feedback-based flow ratiometry. Talanta. 64: 1169-74. PMID 18969725 DOI: 10.1016/J.Talanta.2004.04.007  0.316
2004 Ullah SM, Adams RL, Srinivasan K, Dasgupta PK. Asymmetric membrane fiber-based carbon dioxide removal devices for ion chromatography. Analytical Chemistry. 76: 7084-93. PMID 15571363 DOI: 10.1021/Ac0492160  0.316
2004 Toda K, Ohira SI, Tanaka T, Nishimura T, Dasgupta PK. Field instrument for simultaneous large dynamic range measurement of atmospheric hydrogen sulfide, methanethiol, and sulfur dioxide. Environmental Science & Technology. 38: 1529-1536. PMID 15046356 DOI: 10.1021/Es034450D  0.366
2004 Takeuchi M, Li J, Morris KJ, Dasgupta PK. Membrane-based parallel plate denuder for the collection and removal of soluble atmospheric gases. Analytical Chemistry. 76: 1204-1210. PMID 14961756 DOI: 10.1021/Ac0348423  0.38
2004 Dallas T, Dasgupta PK. Light at the end of the tunnel: Recent analytical applications of liquid-core waveguides Trac - Trends in Analytical Chemistry. 23: 385-392. DOI: 10.1016/S0165-9936(04)00522-9  0.316
2003 Jo KD, Dasgupta PK. Continuous on-line feedback based flow titrations. Complexometric titrations of calcium and magnesium. Talanta. 60: 131-7. PMID 18969033 DOI: 10.1016/S0039-9140(03)00114-0  0.351
2003 Al-Horr R, Samanta G, Dasgupta PK. A Continuous Analyzer for Soluble Anionic Constituents and Ammonium in Atmospheric Particulate Matter Environmental Science and Technology. 37: 5711-5720. PMID 14717184 DOI: 10.1021/Es034464J  0.41
2003 Toda K, Yoshioka KI, Ohira SI, Li J, Dasgupta PK. Trace gas measurement with an integrated porous tube collector/long-path absorbance detector. Analytical Chemistry. 75: 4050-4056. PMID 14632117 DOI: 10.1021/Ac0341719  0.376
2003 Kirk AB, Smith EE, Tian K, Anderson TA, Dasgupta PK. Perchlorate in milk. Environmental Science & Technology. 37: 4979-81. PMID 14620826 DOI: 10.1021/Es034735Q  0.308
2003 Gorbounov V, Kuban P, Dasgupta PK, Temkin H. A nanoinjector for microanalysis. Analytical Chemistry. 75: 3919-23. PMID 14572063 DOI: 10.1021/Ac034342+  0.343
2003 Li J, Dasgupta PK. Selective measurement of gaseous hydrogen peroxide with light emitting diode-based liquid-core waveguide absorbance detector Analytical Sciences. 19: 517-523. PMID 12725385 DOI: 10.2116/Analsci.19.517  0.348
2003 Tian K, Dasgupta PK, Anderson TA. Determination of trace perchlorate in high-salinity water samples by ion chromatography with on-line preconcentration and preelution Analytical Chemistry. 75: 701-706. PMID 12585505 DOI: 10.1021/Ac026268L  0.366
2003 Datta A, Eom IY, Dhar A, Kuban P, Manor R, Ahmad I, Gangopadhyay S, Dallas T, Holtz M, Temkin H, Dasgupta PK. Microfabrication and characterization of Teflon AF-coated liquid core waveguide channels in silicon Ieee Sensors Journal. 3: 788-795. DOI: 10.1109/Jsen.2003.820343  0.33
2003 Genfa Z, Slanina S, Brad Boring C, Jongejan PA, Dasgupta PK. Continuous wet denuder measurements of atmospheric nitric and nitrous acids during the 1999 Atlanta Supersite Atmospheric Environment. 37: 1351-1364. DOI: 10.1016/S1352-2310(02)01011-7  0.341
2003 Dasgupta PK, Eom I, Morris KJ, Li J. Light emitting diode-based detectors Analytica Chimica Acta. 500: 337-364. DOI: 10.1016/S0003-2670(03)00575-0  0.338
2003 Tanaka H, Aritsuka K, Tachibana T, Chuman H, Dasgupta PK. Determination of dissociation constants of weak acids by feedback-based flow ratiometry Analytica Chimica Acta. 499: 199-204. DOI: 10.1016/S0003-2670(03)00530-0  0.309
2003 Larsson H, Dasgupta PK. Liquid core waveguide-based optical spectrometry for field estimation of dissolved BTEX compounds in groundwater: A feasibility study Analytica Chimica Acta. 485: 155-167. DOI: 10.1016/S0003-2670(03)00423-9  0.32
2003 Li Q, Morris KJ, Dasgupta PK, Raimundo IM, Temkin H. Portable flow-injection analyzer with liquid-core waveguide based fluorescence, luminescence, and long path length absorbance detector Analytica Chimica Acta. 479: 151-165. DOI: 10.1016/S0003-2670(02)01531-3  0.366
2002 Dasgupta PK, Huang H, Zhang G, Cobb GP. Photometric measurement of trace As(III) and As(V) in drinking water. Talanta. 58: 153-64. PMID 18968742 DOI: 10.1016/S0039-9140(02)00264-3  0.774
2002 Scott Kephart T, Dasgupta PK. Superheated water eluent capillary liquid chromatography. Talanta. 56: 977-87. PMID 18968577 DOI: 10.1016/S0039-9140(02)00049-8  0.305
2002 Ohira SI, Toda K, Ikebe SI, Dasgupta PK. Hybrid microfabricated device for field measurement of atmospheric sulfur dioxide. Analytical Chemistry. 74: 5890-5896. PMID 12463377 DOI: 10.1021/Ac025940B  0.362
2002 Kuban P, Dasgupta PK, Morris KA. Microscale continuous ion exchanger. Analytical Chemistry. 74: 5667-75. PMID 12433103 DOI: 10.1021/Ac0258397  0.337
2002 Boring CB, Al-Horr R, Genfa Z, Dasgupta PK, Martin MW, Smith WF. Field measurement of acid gases and soluble anions in atmospheric particulate matter using a parallel plate wet denuder and an alternating filter-based automated analysis system Analytical Chemistry. 74: 1256-1268. PMID 11922292 DOI: 10.1021/Ac015643R  0.318
2002 Dasgupta PK. Chapter 5 Automated diffusion-based collection and measurement of atmospheric trace gases Comprehensive Analytical Chemistry. 37: 97-160. DOI: 10.1016/S0166-526X(02)80042-3  0.34
2002 Dasgupta PK, Jo KD. Feedback based continuous flow titrations with electrogenerated titrants Electroanalysis. 14: 1383-1390. DOI: 10.1002/1521-4109(200211)14:19/20<1383::Aid-Elan1383>3.0.Co;2-I  0.346
2001 Toda K, Dasgupta PK, Li J, Tarver GA, Zarus GM. Fluorometric field instrument for continuous measurement of atmospheric hydrogen sulfide. Analytical Chemistry. 73: 5716-5724. PMID 11774912 DOI: 10.1021/Ac010602G  0.387
2001 Al-Horr R, Dasgupta PK, Adams RL. Two-Dimensional detection in ion chromatography: sequential conductometry after suppression and passive hydroxide introduction. Analytical Chemistry. 73: 4694-703. PMID 11605849 DOI: 10.1021/Ac0105336  0.36
2001 Wang S, Huang X, Fang Z, Dasgupta PK. A miniaturized liquid core waveguide-capillary electrophoresis system with flow injection sample introduction and fluorometric detection using light-emitting diodes. Analytical Chemistry. 73: 4545-4549. PMID 11575805 DOI: 10.1021/Ac010341A  0.379
2001 Li J, Dasgupta PK. Measurement of gaseous hydrogen peroxide with a liquid core waveguide chemiluminescence detector Analytica Chimica Acta. 442: 63-70. DOI: 10.1016/S0003-2670(01)01102-3  0.352
2001 Dasgupta PK, Tanaka H, Jo KD. Continuous on-line true titrations by feedback based flow ratiometry: application to potentiometric acid–base titrations Analytica Chimica Acta. 435: 289-297. DOI: 10.1016/S0003-2670(01)00864-9  0.328
2001 Milani MR, Dasgupta PK. Measurement of nitrogen dioxide and nitrous acid using gas-permeable liquid core waveguides Analytica Chimica Acta. 431: 169-180. DOI: 10.1016/S0003-2670(00)01331-3  0.346
2001 Galanis S, Dasgupta PK. Measurement of parts per million levels of potassium hydroxide in polyether polyol streams Analytica Chimica Acta. 429: 101-110. DOI: 10.1016/S0003-2670(00)01261-7  0.378
2001 Waiz S, Cedillo BM, Jambunathan S, Hohnholt SG, Dasgupta PK, Wolcott DK. Dispersion in open tubular reactors of various geometries Analytica Chimica Acta. 428: 163-171. DOI: 10.1016/S0003-2670(00)01230-7  0.346
2001 Li J, Dasgupta PK, Genfa Z, Hutterli MA. Measurement of atmospheric formaldehyde with a diffusion scrubber and light-emitting diode-liquid-core waveguide based fluorometry Field Analytical Chemistry & Technology. 5: 2-12. DOI: 10.1002/Fact.1001  0.387
2000 Tanaka H, Dasgupta PK, Huang J. Continuous on-line true titrations by feedback-based flow ratiometry. The principle of compensating errors Analytical Chemistry. 72: 4713-4720. PMID 11028636 DOI: 10.1021/Ac000598T  0.327
2000 Borba BMD, Kinchin CM, Sherman D, Cook TK, Dasgupta PK, Srinivasan K, Pohl CA. Ion chromatographic determination of acidity. Analytical Chemistry. 72: 96-100. PMID 10655640 DOI: 10.1021/Ac9907787  0.343
2000 Li J, Dasgupta PK. A simple instrument for ultraviolet-visible absorption spectrophotometry in high temperature molten salt media Review of Scientific Instruments. 71: 2283-2287. DOI: 10.1063/1.1150442  0.309
2000 Li J, Dasgupta PK. Measurement of atmospheric hydrogen peroxide and hydroxymethyl hydroperoxide with a diffusion scrubber and light emitting diode-liquid core waveguide-based fluoromentry Analytical Chemistry. 72: 5338-5347. DOI: 10.1021/Ac000611+  0.36
2000 Genfa Z, Dasgupta PK. A continuous film-recirculable drop gas-liquid equilibration device. Measurement of trace gaseous ammonia Analytical Chemistry. 72: 3165-3170. DOI: 10.1021/Ac000069P  0.366
2000 Tian K, Dasgupta PK. Simultaneous flow-injection measurement of hydroxide, chloride, hypochlorite and chlorate in Chlor-alkali cell effluents Talanta. 52: 623-630. DOI: 10.1016/S0039-9140(00)00399-4  0.373
2000 Kephart TS, Dasgupta PK. Hot eluent capillary liquid chromatography using zirconia and titania based stationary phases Analytica Chimica Acta. 414: 71-78. DOI: 10.1016/S0003-2670(00)00821-7  0.305
2000 Tian K, Dasgupta PK, Shermer WD. Determination of oxidative stability of lipids in solid samples Journal of the American Oil Chemists' Society. 77: 217-222. DOI: 10.1007/S11746-000-0035-3  0.31
1999 Li J, Dasgupta PK, Genfa Z. Transversely illuminated liquid core waveguide based fluorescence detection: Fluorometric flow injection determination of aqueous ammonium/ammonia Talanta. 50: 617-623. PMID 18967752 DOI: 10.1016/S0039-9140(99)00148-4  0.342
1999 Jambunathan S, Dasgupta PK, Wolcott DK, Marshall GD, Olson DC. Optical fiber coupled light emitting diode based absorbance detector with a reflective flow cell. Talanta. 50: 481-490. PMID 18967738 DOI: 10.1016/S0039-9140(99)00132-0  0.328
1999 Boring CB, Poruthoor SK, Dasgupta PK. Wet effluent parallel plate diffusion denuder coupled capillary ion chromatograph for the determination of atmospheric trace gases. Talanta. 48: 675-684. PMID 18967508 DOI: 10.1016/S0039-9140(98)00285-9  0.368
1999 Tian K, Dasgupta PK. Automated measurement of lipid hydroperoxides in oil and fat samples by flow injection photometry Analytical Chemistry. 71: 2053-2058. DOI: 10.1021/Ac9813181  0.336
1999 Holtz M, Dasgupta PK, Zhang G. Small-volume Raman spectroscopy with a liquid core waveguide Analytical Chemistry. 71: 2934-2938. DOI: 10.1021/Ac981261I  0.709
1999 Li J, Dasgupta PK. Chemiluminescence detection with a liquid core waveguide: Determination of ammonium with electrogenerated hypochlorite based on the luminol-hypochlorite reaction Analytica Chimica Acta. 398: 33-39. DOI: 10.1016/S0003-2670(99)00378-5  0.341
1999 Dasgupta PK, Kar S. Effects of separation potential, hydrostatic pressure and auxiliary electroosmotic pumping on a suppressed conductometric capillary electrophoresis separation system Analytica Chimica Acta. 394: 1-12. DOI: 10.1016/S0003-2670(99)00209-3  0.319
1999 Sjögren A, Dasgupta PK. A planar microelectrodialytic NaOH generator for eluite conversion after suppressed conductometric detection in ion chromatography Analytica Chimica Acta. 384: 135-141. DOI: 10.1016/S0003-2670(98)00831-9  0.349
1999 Huang H, Dasgupta PK. A field-deployable instrument for the measurement and speciation of arsenic in potable water Analytica Chimica Acta. 380: 27-37. DOI: 10.1016/S0003-2670(98)00649-7  0.604
1999 Kar S, Dasgupta PK. Improving resolution in capillary zone electrophoresis through bulk flow control Microchemical Journal. 62: 128-137. DOI: 10.1006/Mchj.1999.1718  0.329
1998 Poruthoor SK, Dasgupta PK, Genfa Z. Indoor Air Pollution and Sick Building Syndrome. Monitoring Aerosol Protein as a Measure of Bioaerosols Environmental Science & Technology. 32: 1147-1152. DOI: 10.1021/Es9710058  0.329
1998 Dasgupta PK, Genfa Z, Poruthoor SK, Caldwell S, Dong S, Liu S. High-Sensitivity Gas Sensors Based on Gas-Permeable Liquid Core Waveguides and Long-Path Absorbance Detection Analytical Chemistry. 70: 4661-4669. DOI: 10.1021/Ac980803T  0.695
1998 Boring CB, Dasgupta PK, Sjögren A. Compact, field-portable capillary ion chromatograph Journal of Chromatography A. 804: 45-54. DOI: 10.1016/S0021-9673(98)00139-3  0.399
1998 Poruthoor SK, Dasgupta PK. Automated particle collection and analysis. Near-real time measurement of aerosol cerium (III) Analytica Chimica Acta. 361: 151-159. DOI: 10.1016/S0003-2670(97)00700-9  0.321
1998 Surowiec K, Dasgupta PK. Collection of Atmospheric Gases in a Liquid Film Suspended on a Loop: Determination of Formic and Acetic Acids by Exhaustive Electromigration Injection Capillary Electrophoresis Journal of Microcolumn Separations. 10: 265-271. DOI: 10.1002/(Sici)1520-667X(1998)10:3<265::Aid-Mcs5>3.0.Co;2-E  0.36
1997 Sjögren A, Boring aCB, Dasgupta PK, Alexander JN. Capillary ion chromatography with on-line high-pressure electrodialytic NaOH eluent production and gradient generation Analytical Chemistry. 69: 1385-1391. PMID 21639344 DOI: 10.1021/Ac961215N  0.351
1997 Cardoso AA, Liu H, Dasgupta PK. Fluorometric fiber optic drop sensor for atmospheric hydrogen sulfide. Talanta. 44: 1099-1106. PMID 18966842 DOI: 10.1016/S0039-9140(96)02202-3  0.358
1997 Pereira EA, Dasgupta PK. Measurement of atmospheric formaldehyde using a drop collector and in-situ colorimetry International Journal of Environmental Analytical Chemistry. 66: 201-213. DOI: 10.1080/03067319708028363  0.365
1997 Gilpin T, Apel E, Fried A, Wert B, Calvert J, Genfa Z, Dasgupta P, Harder JW, Heikes B, Hopkins B, Westberg H, Kleindienst T, Lee YN, Zhou X, Lonneman W, et al. Intercomparison of six ambient [CH2O] measurement techniques Journal of Geophysical Research: Atmospheres. 102: 21161-21188. DOI: 10.1029/97Jd01314  0.311
1997 Dasgupta PK, Ni L, Poruthoor SK, Hindes DC. A Multiple Parallel Plate Wetted Screen Diffusion Denuder for High-Flow Air Sampling Applications Analytical Chemistry. 69: 5018-5023. DOI: 10.1021/Ac970510K  0.36
1997 Liu H, Dasgupta PK. A Falling Drop for Sample Injection in Capillary Zone Electrophoresis Analytical Chemistry. 69: 1211-1216. DOI: 10.1021/Ac961049J  0.721
1997 Huang H, Dasgupta PK. Renewable liquid film-based electrochemical sensor for gaseous hydroperoxides Talanta. 44: 605-615. DOI: 10.1016/S0039-9140(96)02069-3  0.588
1997 Boring CB, Dasgupta PK. An affordable high-performance optical absorbance detector for capillary systems Analytica Chimica Acta. 342: 123-132. DOI: 10.1016/S0003-2670(96)00571-5  0.346
1997 Liu H, Dasgupta PK. A Liquid Drop: What Is It Good For? Microchemical Journal. 57: 127-136. DOI: 10.1006/Mchj.1997.1498  0.707
1997 Huang H, Dasgupta PK. Electrochemical Sensing of Gases Based on Liquid Collection Interfaces Electroanalysis. 9: 585-591. DOI: 10.1002/Elan.1140090802  0.602
1996 Huang H, Dasgupta PK, Genfa Z, Wang J. A pulse amperometric sensor for the measurement of atmospheric hydrogen peroxide. Analytical Chemistry. 68: 2062-2066. PMID 21619294 DOI: 10.1021/Ac960143X  0.618
1996 Murayama M, Dasgupta PK. Liquid chromatographic determination of nitro-substituted polynuclear aromatic hydrocarbons by sequential electrochemical and fluorescence detection. Analytical Chemistry. 68: 1226-32. PMID 21619153 DOI: 10.1021/Ac950933R  0.333
1996 Kar S, Dasgupta PK. Measurement of phenols on a loop-supported liquid him by micellar electrokinetic chromatography and direct UV detection Journal of Chromatography A. 739: 379-387. PMID 8765855 DOI: 10.1016/0021-9673(96)00031-3  0.358
1996 Dasgupta PK, Surowiec K. Electromigration Injection from a Small Loop in Capillary Electrophoresis Analytical Chemistry. 68: 4291-4299. DOI: 10.1021/Ac960663S  0.346
1996 Liu S, Dasgupta PK. Automated System for Chemical Analysis of Airborne Particles Based on Corona-Free Electrostatic Collection Analytical Chemistry. 68: 3638-3644. DOI: 10.1021/Ac960340W  0.317
1996 Liu H, Dasgupta PK. Analytical chemistry in a drop. solvent extraction in a microdrop Analytical Chemistry. 68: 1817-1821. DOI: 10.1021/Ac960145H  0.338
1996 Sjögren A, Dasgupta PK. Enhancement of separation efficiency in capillary electrophoresis by electrostacking without liquid contact Analytical Chemistry. 68: 1933-1940. DOI: 10.1021/Ac951126V  0.342
1996 Dasgupta PK, Surowiec K. Quantitative injection from a microloop. Reproducible volumetric sample introduction in capillary zone electrophoresis Analytical Chemistry. 68: 1164-1168. DOI: 10.1021/Ac951123I  0.318
1996 Liu H, Dasgupta PK. Analytical chemistry in a drop Trac - Trends in Analytical Chemistry. 15: 468-475. DOI: 10.1016/S0165-9936(96)00065-9  0.726
1996 Liu S, Dasgupta PK. An electrostatic micro-collection interface for aerosol collection. Automated ion chromatographic analysis of aerosols Talanta. 43: 1681-1688. DOI: 10.1016/0039-9140(96)01933-9  0.33
1996 Liu H, Dasgupta PK. A liquid drop: A windowless optical cell and a reactor without walls for flow injection analysis Analytica Chimica Acta. 326: 13-22. DOI: 10.1016/0003-2670(96)00040-2  0.75
1996 Kar S, Dasgupta PK. Direct Coupling of Ion Chromatography with Suppressed Conductometric Capillary Electrophoresis Journal of Microcolumn Separations. 8: 561-568. DOI: 10.1002/(Sici)1520-667X(1996)8:8<561::Aid-Mcs6>3.0.Co;2-#  0.337
1995 Simon PK, Dasgupta PK. Continuous automated measurement of gaseous nitrous and nitric acids and particulate nitrite and nitrate. Environmental Science & Technology. 29: 1534-41. PMID 22276874 DOI: 10.1021/Es00006A015  0.796
1995 Staffelbach T, Neftel A, Dasgupta PK. Artifact peroxides produced during cryogenic sampling of ambient air Geophysical Research Letters. 22: 2605-2608. DOI: 10.1029/95Gl02865  0.314
1995 Liu H, Dasgupta PK. A Renewable Liquid Droplet as a Sampler and a Windowless Optical Cell. Automated Sensor for Gaseous Chlorine Analytical Chemistry. 67: 4221-4228. DOI: 10.1021/Ac00119A003  0.732
1995 Dasgupta PK, Kar S. Measurement of gases by a suppressed conductometric capillary electrophoresis separation system Analytical Chemistry. 67: 3853-3860. DOI: 10.1021/Ac00117A006  0.333
1995 Cardoso AA, Dasgupta PK. Analytical chemistry in a liquid film/droplet Analytical Chemistry. 67: 2562-2566. DOI: 10.1021/Ac00111A011  0.377
1995 Sjögren A, Dasgupta PK. Two-dimensional conductometric detection in ion chromatography. Analyte identification, quantitation of very weak acid anions, and universal calibration Analytical Chemistry. 67: 2110-2118. DOI: 10.1021/Ac00109A033  0.362
1995 Liu S, Dasgupta PK. Liquid droplet. A renewable gas sampling interface Analytical Chemistry. 67: 2042-2049. DOI: 10.1021/Ac00109A023  0.336
1995 Simon PK, Dasgupta PK. Continuous automated measurement of the soluble fraction of atmospheric particulate matter Analytical Chemistry. 67: 71-78. DOI: 10.1021/Ac00097A012  0.792
1995 Tarver GA, Dasgupta PK. Design and development of a system to measure ambient levels of hydrogen sulfide and lower mercaptans from a mobile platform Atmospheric Environment. 29: 1291-1298. DOI: 10.1016/1352-2310(95)00040-6  0.312
1995 Liu S, Dasgupta PK. Electroosmotically pumped capillary format sequential injection analysis with a membrane sampling interface for gaseous analytes Analytica Chimica Acta. 308: 281-285. DOI: 10.1016/0003-2670(94)00478-5  0.339
1995 Huang H, Dasgupta PK. Fast voltammetric sensors for the measurement of soil water activity Electroanalysis. 7: 626-632. DOI: 10.1002/Elan.1140070705  0.56
1994 Zheng HJ, Dasgupta PK. Concentration and Optical Measurement of Aqueous Analytes in an Organic Solvent Segmented Capillary under High Electric Field Analytical Chemistry. 66: 3997-4004. DOI: 10.1021/Ac00094A023  0.305
1994 Dasgupta PK, Llu S. Auxiliary electroosmotic pumping in capillary electrophoresis Analytical Chemistry. 66: 3060-3065. DOI: 10.1021/Ac00091A012  0.356
1994 Kar S, Dasgupta PK, Liu H, Hwang H. Computer-Interfaced Bipolar Pulse Conductivity Detector for Capillary Systems Analytical Chemistry. 66: 2537-2543. DOI: 10.1021/Ac00087A019  0.787
1994 Dasgupta PK, Zhang G, Schulze S, Marx JN. Measurement of Carbonyl Compounds as the 2,4-Dinitrophenylhydrazonate Anion. Reaction Mechanism and an Automated Measurement System Analytical Chemistry. 66: 1965-1970. DOI: 10.1021/Ac00085A007  0.697
1994 Dasgupta PK, Liu S. Electroosmosis: A reliable fluid propulsion system for flow injection analysis Analytical Chemistry. 66: 1792-1798. DOI: 10.1021/Ac00083A004  0.302
1994 Fan Q, Dasgupta PK. Continuous Automated Determination of Atmospheric Formaldehyde at the Parts Per Trillion Level Analytical Chemistry. 66: 551-556. DOI: 10.1021/Ac00076A021  0.389
1994 Liu S, Dasgupta PK. Sequential injection analysis in capillary format with an electroosmotic pump Talanta. 41: 1903-1910. DOI: 10.1016/0039-9140(94)00145-6  0.311
1994 Liu H, Dasgupta PK. Dual-wavelength photometry with light emitting diodes. Compensation of refractive index and turbidity effects in flow-injection analysis Analytica Chimica Acta. 289: 347-353. DOI: 10.1016/0003-2670(94)90011-X  0.732
1994 Liu H, Dasgupta PK. Flow-injection extraction without phase separation based on dual-wavelength spectrophotometry Analytica Chimica Acta. 288: 237-245. DOI: 10.1016/0003-2670(94)80136-3  0.743
1993 Liu H, Dasgupta PK, Zheng HJ. High performance optical absorbance detectors based on low noise switched integrators. Talanta. 40: 1331-1338. PMID 18965786 DOI: 10.1016/0039-9140(93)80206-7  0.312
1993 Chung HK, Dasgupta PK, Marx JN. Spectrophotometric determination of H2O2 with 1-anilinonaphthalene-8-sulfonic acid and 4-aminoantipyrine with hematin as catalyst Talanta. 40: 981-988. PMID 18965736 DOI: 10.1016/0039-9140(93)80154-J  0.325
1993 Dasgupta PK, Bellamy HS, Liu H. Sandwich-type flow-through fiber-optic cells for optical absorbance measurements. Talanta. 40: 341-345. PMID 18965635 DOI: 10.1016/0039-9140(93)80243-K  0.765
1993 Dasgupta PK, Bellamy HS, Liu H, Lopez JL, Loree EL, Morris K, Petersen K, Mir KA. Light emitting diode based flow-through optical absorption detectors Talanta. 40: 53-74. PMID 18965596 DOI: 10.1016/0039-9140(93)80142-E  0.75
1993 Berglund I, Dasgupta PK, Lopez JL, Nara O. Two-dimensional conductometric detection in ion chromatography: sequential suppressed and single column detection Analytical Chemistry. 65: 1192-1198. DOI: 10.1021/Ac00057A015  0.792
1993 Simon PK, Dasgupta PK. Wet effluent denuder coupled liquid/ion chromatography systems: Annular and parallel plate denuders Analytical Chemistry. 65: 1134-1139. DOI: 10.1021/Ac00057A006  0.797
1993 Dasgupta PK, Bao L. Suppressed conductometric capillary electrophoresis separation systems Analytical Chemistry. 65: 1003-1011. DOI: 10.1021/Ac00056A010  0.389
1993 Kubáň V, Dasgupta PK. Comparison of photometry and conductometry for the determination of total carbonate by gas permeation flow injection analysis Talanta. 40: 831-840. DOI: 10.1016/0039-9140(93)80038-S  0.323
1993 Liu S, Dasgupta PK. A simple means to increase absorbance detection sensitivity in capillary zone electrophoresis Analytica Chimica Acta. 283: 747-753. DOI: 10.1016/0003-2670(93)85289-V  0.349
1993 Liu S, Dasgupta PK. Electroosmotically pumped capillary flow-injection analysis. Valve-based injection systems and sample throughput Analytica Chimica Acta. 283: 739-745. DOI: 10.1016/0003-2670(93)85288-U  0.335
1993 Sato H, Dasgupta PK. Analyte identification in ion chromatography Electromigration governed chronoamperometric profiles Analytica Chimica Acta. 284: 27-36. DOI: 10.1016/0003-2670(93)80004-5  0.331
1992 Chung HK, Bellamy HS, Dasgupta PK. Determination of aqueous ozone for potable water treatment applications by chemiluminescence flow-injection analysis. A feasibility study Talanta. 39: 593-598. PMID 18965422 DOI: 10.1016/0039-9140(92)80066-M  0.783
1992 Lindgren CC, Dasgupta PK. Flow injection and solvent extraction with intelligent segment separation. Determination of quaternary ammonium ions by ion-pairing. Talanta. 39: 101-11. PMID 18965347 DOI: 10.1016/0039-9140(92)80003-V  0.338
1992 Kuban V, Dasgupta PK, Marx JN. Nitroprusside and methylene blue methods for silicone membrane differentiated flow injection determination of sulfide in water and wastewater. Analytical Chemistry. 64: 36-43. PMID 1736678 DOI: 10.1021/Ac00025A008  0.364
1992 Genfa Z, Dasgupta PK. Hematin as a peroxidase substitute in hydrogen peroxide determinations Analytical Chemistry. 64: 517-522. PMID 1575321 DOI: 10.1021/Ac00029A013  0.305
1992 Huang H, Dasgupta PK. Voltammetric sensor for determination of water in liquids Analytical Chemistry. 64: 2406-2412. DOI: 10.1021/Ac00044A018  0.586
1992 Kubáň V, Dasgupta PK. Selective determination of gases by two-stage membrane-differentiated flow injection analysis. Determination of trace hydrogen cyanide in the presence of large concentrations of hydrogen sulfide Analytical Chemistry. 64: 1106-1112. DOI: 10.1021/Ac00034A007  0.347
1992 Bao L, Dasgupta PK. Membrane interfaces for sample introduction in capillary zone electrophoresis Analytical Chemistry. 64: 991-996. DOI: 10.1021/Ac00033A006  0.31
1992 Liu S, Dasgupta PK. Flow-injection analysis in the capillary format using electroosmotic pumping Analytica Chimica Acta. 268: 1-6. DOI: 10.1016/0003-2670(92)85243-Y  0.38
1992 Zhang G, Dasgupta PK, Sigg A. Determination of gaseous hydrogen peroxide at parts per trillion levels a Nafion membrane scrubber and a single-line flow-injection system Analytica Chimica Acta. 260: 57-64. DOI: 10.1016/0003-2670(92)80126-R  0.712
1991 Vecera Z, Dasgupta PK. Measurement of ambient nitrous acid and a reliable calibration source for gaseous nitrous acid Environmental Science and Technology. 25: 255-260. DOI: 10.1021/Es00014A006  0.725
1991 Večeřa Z, Dasgupta PK. Measurement of atmospheric nitric and nitrous acids with a wet effluent diffusion denuder and low-pressure ion chromatography-postcolumn reaction detection Analytical Chemistry. 63: 2210-2216. DOI: 10.1021/Ac00020A003  0.76
1991 Berglund I, Dasgupta PK. Two-dimensional conductometric detection in ion chromatography. Postsuppressor conversion of eluite acids to a base Analytical Chemistry. 63: 2175-2183. DOI: 10.1021/Ac00019A019  0.358
1991 Huang H, Dasgupta PK, Ronchinsky S. Perfluorosulfonate ionomer-phosphorus pentoxide composite thin films as amperometric sensors for water Analytical Chemistry. 63: 1570-1573. DOI: 10.1021/Ac00015A013  0.569
1991 Simon PK, Dasgupta PK, Vecera Z. Wet effluent denuder coupled liquid/ion chromatography systems Analytical Chemistry. 63: 1237-1242. DOI: 10.1021/Ac00013A011  0.781
1991 Strong DL, Dasgupta PK, Friedman K, Stillian JR. Electrodialytic eluent production and gradient generation in ion chromatography Analytical Chemistry. 63: 480-486. DOI: 10.1021/Ac00005A019  0.787
1991 Sonne K, Dasgupta PK. Simultaneous photometric flow injection determination of sulfide, polysulfide, sulfite, thiosulfate, and sulfate Analytical Chemistry. 63: 427-432. DOI: 10.1021/Ac00005A008  0.799
1991 Strong DL, Dasgupta PK. Electrodialytic production of gas-free sodium hydroxide based on Donnan breakdown Journal of Membrane Science. 57: 321-336. DOI: 10.1016/S0376-7388(00)80687-0  0.795
1991 Zhang G, Dasgupta PK, Cheng Y. Design of a straight inlet diffusion scrubber. Comparison of particle transmission with other collection devices and characterization for the measurement of hydrogen peroxide and formaldehyde Atmospheric Environment. Part a. General Topics. 25: 2717-2729. DOI: 10.1016/0960-1686(91)90202-I  0.699
1991 Dong S, Dasgupta PK. Automated determination of total phosphorus in aqueous samples Talanta. 38: 133-137. DOI: 10.1016/0039-9140(91)80120-O  0.699
1991 Irgum K, Genborg Å, Glad B, Gupta S, Dasgupta PK. Effects of alternating electric fields on transport through ion exchange membranes Electroanalysis. 3: 783-792. DOI: 10.1002/Elan.1140030811  0.779
1990 Dasgupta PK, Dong S, Hwang H. Diffusion scrubber-based field measurements of atmospheric formaldehyde and hydrogen peroxide Aerosol Science and Technology. 12: 12-98. DOI: 10.1080/02786829008959329  0.8
1990 Huang H, Dasgupta PK. Amperometric microsensor for water Analytical Chemistry. 62: 1935-1942. DOI: 10.1021/Ac00217A008  0.563
1990 Dasgupta PK, Nara O. Measurement of acid dissociation constants of weak acids by cation exchange and conductometry Analytical Chemistry. 62: 1117-1122. DOI: 10.1021/Ac00210A005  0.779
1990 Dasgupta PK, Petersen K. Kinetic approach to the measurement of chemical oxygen demand with an automated micro batch analyzer Analytical Chemistry. 62: 395-402. DOI: 10.1021/Ac00203A016  0.784
1990 Kok GL, Schanot AJ, Lindgren PF, Dasgupta PK, Hegg DA, Hobbs PV, Boatman JF. An airborne test of three sulfur dioxide measurement techniques Atmospheric Environment Part a, General Topics. 24: 1903-1908. DOI: 10.1016/0960-1686(90)90522-O  0.789
1989 Ping L, Dasgupta PK. Determination of total mercury in water and urine by a gold film sensor following Fenton's reagent digestion Analytical Chemistry. 61: 1230-1235. PMID 2757207 DOI: 10.1021/Ac00186A011  0.333
1989 Dasgupta PK. Postcolumn techniques: A critical perspective for ion chromatography Journal of Chromatographic Science. 27: 422-448. DOI: 10.1093/Chromsci/27.8.422  0.384
1989 Hisamatsu Y, Ping L, Dasgupta PK. Measurement of trace levels of atmospheric sulfur dioxide with a gold film sensor Journal of the Air and Waste Management Association. 39: 975-980. DOI: 10.1080/08940630.1989.10466585  0.348
1989 Genfa Z, Dasgupta PK, Dong S. Measurement of atmospheric ammonia Environmental Science & Technology. 23: 1467-1474. DOI: 10.1021/Es00070A003  0.652
1989 Dasgupta PK, Lindgren PF. Inlet pressure effects on the collection efficiency of diffusion scrubbers Environmental Science and Technology. 23: 895-897. DOI: 10.1021/Es00065A020  0.779
1989 Okada T, Dasgupta PK, Qi D. Identification of ions in anion chromatography by stopped flow chronoamperometry Analytical Chemistry. 61: 1387-1392. DOI: 10.1021/Ac00188A016  0.77
1989 Qi D, Okada T, Dasgupta PK. Direct current conductivity detection in ion chromatography Analytical Chemistry. 61: 1383-1387. DOI: 10.1021/Ac00188A015  0.769
1989 Strong DL, Dasgupta PK. Electrodialytic membrane suppressor for ion chromatography Analytical Chemistry. 61: 939-945. DOI: 10.1021/Ac00184A005  0.793
1989 Okada T, Dasgupta PK. Selective detection approach to ion exclusion chromatography Analytical Chemistry. 61: 548-554. DOI: 10.1021/Ac00181A010  0.583
1989 Lei W, Dasgupta PK, Lopez JL, Olson DC. Sorbent isolation and elution with an immiscible eluent in flow injection analysis Analytical Chemistry. 61: 496-499. DOI: 10.1021/Ac00180A024  0.454
1989 Genfa Z, Dasgupta PK. Fluorometric measurement of aqueous ammonium ion in a flow injection system Analytical Chemistry. 61: 408-412. DOI: 10.1021/Ac00180A006  0.364
1989 Lindgren PF, Dasgupta PK. Measurement of atmospheric sulfur dioxide by diffusion scrubber coupled ion chromatography Analytical Chemistry. 61: 19-24. DOI: 10.1021/Ac00176A005  0.806
1989 Dasgupta PK, Lei W. Solvent extraction in continuous flow systems with intelligent zone sampling Analytica Chimica Acta. 222: 255-269. DOI: 10.1016/S0003-2670(00)83283-3  0.501
1989 Lei W, Dasgupta PK. Determination of sulfide and mercaptans in caustic scrubbing liquor Analytica Chimica Acta. 226: 165-170. DOI: 10.1016/S0003-2670(00)80915-0  0.528
1989 Petersen K, Dasgupta PK. An air-carrier continuous analysis system Talanta. 36: 49-61. DOI: 10.1016/0039-9140(89)80081-5  0.793
1989 Lei W, Dasgupta PK, Matza SD, Olson DC. Measurement of mercaptans in gasoline Mikrochimica Acta. 99: 35-41. DOI: 10.1007/Bf01242787  0.503
1989 Petersen K, Lopez JL, Dasgupta PK. Multicomponent determinations by a membrane-discriminated gas phase analyzer and successive regression in the fiduciary region Journal of Chemometrics. 3: 601-608. DOI: 10.1002/Cem.1180030408  0.793
1988 Kleindienst TE, Shepson PB, Hodges DN, Nero CM, Arnts RR, Dasgupta PK, Hwang H, Kok GL, Lind JA, Lazrus AL, Mackay GI, Mayne LK, Schiff HI. Comparison of techniques for measurement of ambient levels of hydrogen peroxide. Environmental Science & Technology. 22: 53-61. PMID 22195510 DOI: 10.1021/Es00166A005  0.728
1988 Dasgupta PK, Roy SK. Chelating fluorogenic surfactants for the trace detection of metals Proceedings of Spie - the International Society For Optical Engineering. 910: 95-101. DOI: 10.1117/12.945445  0.737
1988 Gupta S, Dasgupta PK. Advances in membrane suppressors for ion chromatography Journal of Chromatographic Science. 26: 34-38. DOI: 10.1093/Chromsci/26.1.34  0.795
1988 Sweileh JA, Lopez JL, Dasgupta PK. Novel automated micro batch analyzer Review of Scientific Instruments. 59: 2609-2615. DOI: 10.1063/1.1139907  0.748
1988 Dasgupta PK, Vithanage RS, Petersen K. Pulsed reagent introduction through a membrane reactor for flow-injection systems Analytica Chimica Acta. 215: 277-282. DOI: 10.1016/S0003-2670(00)85286-1  0.778
1988 Sweileh JA, Dasgupta PK. Applications of in situ detection with an auto-mated micro batch analyzer Analytica Chimica Acta. 214: 107-120. DOI: 10.1016/S0003-2670(00)80434-1  0.733
1988 Dasgupta PK, Dong S, Hwang H, Yang H, Genfa Z. Continuous liquid-phase fluorometry coupled to a diffusion scrubber for the real-time determination of atmospheric formaldehyde, hydrogen peroxide and sulfur dioxide Atmospheric Environment (1967). 22: 949-963. DOI: 10.1016/0004-6981(88)90273-9  0.809
1988 Kleindienst TE, Shepson PB, Nero CM, Arnts RR, Tejada SB, Mackay GI, Mayne LK, Schiff HI, Lind JA, Kok GL, Lazrus AL, Dasgupta PK, Dong S. An intercomparison of formaldehyde measurement techniques at ambient concentration Atmospheric Environment (1967). 22: 1931-1939. DOI: 10.1016/0004-6981(88)90082-0  0.694
1988 Dasgupta PK, West PW. The application of a passive permeation device for the measurement of sulfur dioxide Atmospheric Environment (1967). 22: 432-433. DOI: 10.1016/0004-6981(88)90054-6  0.528
1987 Philips DA, Dasgupta PK. A Diffusion Scrubber for the Collection of Gaseous Nitric Acid Separation Science and Technology. 22: 1255-1267. DOI: 10.1080/01496398708057178  0.352
1987 Dasgupta PK, Soroka K, Vithanage RS. Metal ion chromatography with fluorescence detection Journal of Liquid Chromatography. 10: 3287-3319. DOI: 10.1080/01483918708081874  0.775
1987 Dong S, Dasgupta PK. Fast fluorometric flow injection analysis of formaldehyde in atmospheric water Environmental Science and Technology. 21: 581-588. DOI: 10.1021/Es00160A009  0.707
1987 Shintani H, Dasgupta PK. High sensitivity optical detection methods in hydroxide eluent suppressed anion chromatography via postsuppression ion exchange Analytical Chemistry. 59: 1963-1970. DOI: 10.1021/Ac00142A015  0.619
1987 Hwang H, Dasgupta PK. Tubular microporous membrane entrapped enzyme reactors for flow injection analysis [1] Analytical Chemistry. 59: 1356-1360. DOI: 10.1021/Ac00136A020  0.728
1987 Shintani H, Dasgupta PK. Gradient anion chromatography with hydroxide and carbonate eluents using simultaneous conductivity and pH detection Analytical Chemistry. 59: 802-808. DOI: 10.1021/Ac00133A003  0.606
1987 Dasgupta PK, Rhee JS. Optical cells with partially reflecting windows as nonlinear absorbance amplifiers Analytical Chemistry. 59: 783-786. DOI: 10.1021/Ac00132A022  0.739
1987 Soroka K, Vithanage RS, Phillips DA, Walker B, Dasgupta PK. Fluorescence properties of metal complexes of 8-hydroxyquinoline-5-sulfonic acid and chromatographic applications Analytical Chemistry. 59: 629-636. DOI: 10.1021/Ac00131A019  0.774
1987 Cassidy RM, Elchuk S, Dasgupta PK. Performance of annular membrane and screen-tee reactors for postcolumn-reaction detection of metal ions separated by liquid chromatography Analytical Chemistry. 59: 85-90. DOI: 10.1021/Ac00128A018  0.387
1986 Dasgupta PK, McDowell WL, Rhee JS. Porous membrane-based diffusion scrubber for the sampling of atmospheric gases The Analyst. 111: 87-90. DOI: 10.1039/An9861100087  0.771
1986 Dong S, Dasgupta PK. Solubility of gaseous formaldehyde in liquid water and generation of trace standard gaseous formaldehyde Environmental Science and Technology. 20: 637-640. DOI: 10.1021/Es00148A016  0.674
1986 Dasgupta PK, Gupta VK. Membrane-based flow injection system for determination of sulfur(IV) in atmospheric water Environmental Science and Technology. 20: 524-526. DOI: 10.1021/Es00147A015  0.603
1986 Hwang H, Dasgupta PK. Fluorometric flow injection determination of aqueous peroxides at nanomolar level using membrane reactors Analytical Chemistry. 58: 1521-1524. DOI: 10.1021/Ac00298A055  0.314
1986 Vithanage RS, Dasgupta PK. Quantitative study of chemical equilibria by flow injection analysis with diode array detection Analytical Chemistry. 58: 326-330. DOI: 10.1021/Ac00293A014  0.786
1986 Dasgupta PK, Yang HC. Trace determination of aqueous sulfite, sulfide, and methanethiol by fluorometric flow injection analysis Analytical Chemistry. 58: 2839-2844. DOI: 10.1021/Ac00126A055  0.622
1986 Mercurio-Cason MA, Dasgupta PK, Blakely DW, Johnson RL. An annular dual-membrane continuous cation exchanger packed with ion exchange resin Journal of Membrane Science. 27: 31-40. DOI: 10.1016/S0376-7388(00)81380-0  0.355
1986 Dong S, Dasgupta PK. On the formaldehyde-bisulfite-hydroxymethanesulfonate equilibrium Atmospheric Environment (1967). 20: 1635-1637. DOI: 10.1016/0004-6981(86)90253-2  0.677
1986 Dasgupta PK, Dong S. Solubility of ammonia in liquid water and generation of trace levels of standard gaseous ammonia Atmospheric Environment (1967). 20: 565-570. DOI: 10.1016/0004-6981(86)90099-5  0.7
1986 Sweileh JA, Dasgupta PK, Lopez JL. Measurement of total alkali and phenol in process liquor by FIA Mikrochimica Acta. 90: 175-186. DOI: 10.1007/Bf01364299  0.751
1986 Phillips DA, Soroka K, Vithanage RS, Dasgupta PK. Enhancement and quenching of fluorescence of metal chelates of 8-hydroxyquinoline-5-sulfonic acid Mikrochimica Acta. 88: 207-220. DOI: 10.1007/Bf01196613  0.769
1985 Rhee JS, Dasgupta PK. The second dissociation constant of SO2·H2O Journal of Physical Chemistry. 89: 1799-1804. DOI: 10.1021/J100255A052  0.748
1985 Rhee JS, Dasgupta PK. The second dissociation constant of sulfur dioxide.water The Journal of Physical Chemistry. 89: 1799-1804. DOI: 10.1021/J100255A052  0.737
1985 Hwang H, Dasgupta PK. Thermodynamics of the hydrogen peroxide-water system Environmental Science and Technology. 19: 255-258. DOI: 10.1021/Es00133A006  0.72
1985 Dasgupta PK, Bligh R, Mercurio MA. Dual Membrane Annular Hellical Suppressors in Ion Chromatography Analytical Chemistry. 57: 484-489. DOI: 10.1021/Ac50001A038  0.315
1985 Dasgupta PK, Hwang H. Application of a nested loop system for the flow injection analysis of trace aqueous peroxides Analytical Chemistry. 57: 1009-1012. DOI: 10.1021/Ac00283A010  0.731
1985 Hwang H, Dasgupta PK. Fluorimetric determination of trace hydrogen peroxide in water with a flow injection system Analytica Chimica Acta. 170: 347-352. DOI: 10.1016/S0003-2670(00)81761-4  0.754
1985 Rhee JS, Dasgupta PK. Determination of acids, bases, metal ions and redox species by peak width measurement flow injection analysis with potentiometric, conductometric, fluorometric and spectrophotometric detection Mikrochimica Acta. 87: 107-122. DOI: 10.1007/Bf01201990  0.777
1985 Hwang H, Dasgupta PK. Flow injection analysis of trace hydrogen peroxide using an immobilized enzyme reactor Mikrochimica Acta. 87: 77-87. DOI: 10.1007/Bf01201987  0.745
1985 Rhee JS, Dasgupta PK. Studies on peak width measurement-based FIA acid-base determinations Mikrochimica Acta. 87: 49-64. DOI: 10.1007/Bf01201985  0.772
1985 Hwang H, Dasgupta PK. Spectrophotometric determination of trace aqueous sulfate using barium-beryllon II Mikrochimica Acta. 85: 313-324. DOI: 10.1007/Bf01201527  0.741
1984 Dasgupta PK. Viscosity Detection with a Pulseless PUMP for Liquid Chromatography Journal of Liquid Chromatography. 7: 2367-2382. DOI: 10.1080/01483918408068883  0.313
1984 Dasgupta PK. A diffusion scrubber for the collection of atmospheric gases Atmospheric Environment (1967). 18: 1593-1599. DOI: 10.1016/0004-6981(84)90381-0  0.328
1984 McDowell WL, Dasgupta PK. Determination of S(IV) at low parts per billion levels with anthranillic acid Atmospheric Environment (1967). 18: 2209-2213. DOI: 10.1016/0004-6981(84)90208-7  0.343
1984 Dasgupta PK. Oxaldihydroxamic acid as a new reagent for the fixation of atmospheric sulfur dioxide Atmospheric Environment (1967). 18: 477-478. DOI: 10.1016/0004-6981(84)90127-6  0.335
1984 Hwang H, Dasgupta PK. Microtitration of Sulfate with Beryllon II as indicator: Determination of sulfate in environmental samples Mikrochimica Acta. 83: 159-168. DOI: 10.1007/Bf01207064  0.74
1982 Dasgupta PK. On the ion chromatographic determination of S(IV) Atmospheric Environment (1967). 16: 1265-1268. DOI: 10.1016/0004-6981(82)90217-7  0.316
1982 Dasgupta PK, DeCesare KB, Brummer M. Determination of s(iv) in particulate matter Atmospheric Environment (1967). 16: 917-927. DOI: 10.1016/0004-6981(82)90177-9  0.305
1980 Dasgupta PK, Raabe OG, Duvall TR, Tarkington BK. Generatation and characterization of sodium sulfite aerosols for applications in inhalation toxicologic research. American Industrial Hygiene Association Journal. 41: 660-665. PMID 7457388 DOI: 10.1080/15298668091425464  0.33
1980 Dasgupta PK, DeCesare K, Ullrey JC. Determination of atmospheric sulfur dioxide without tetrachloromercurate(II) and the mechanism of the Schiff reaction Analytical Chemistry. 52: 1912-1922. DOI: 10.1021/Ac50062A031  0.348
1979 Dasgupta PK, Nayak A, Newkome GR, West PW. Structure elucidation of polynitrated 2-aminoperimidines The Journal of Organic Chemistry. 44: 2582-2585. DOI: 10.1021/Jo01328A058  0.485
1979 Hardy JK, Dasgupta PK, Reiszner KD, West PW. A personal chlorine monitor utilizing permeation sampling Environmental Science and Technology. 13: 1090-1093. DOI: 10.1021/Es60157A005  0.571
1979 Dasgupta PK, Mitchell PA, West PW. Study of transition metal ion-S(IV) systems Atmospheric Environment. 13: 775-782. DOI: 10.1016/0004-6981(79)90268-3  0.557
1979 Dasgupta PK, Lundquist GL, West PW. Specific determination of aerosol sulfuric acid in the presence of ammonium sulfate. A laboratory study Atmospheric Environment (1967). 13: 767-774. DOI: 10.1016/0004-6981(79)90267-1  0.583
1979 Dasgupta PK, West PW. The measurement of the sulfuric acid and sulfate content of particulate matter resulting from the combustion of coal and oil Atmospheric Environment (1967). 13: 1221-1222. DOI: 10.1016/0004-6981(79)90052-0  0.528
1978 Dasgupta PK, Hanley LG, West PW. Spectrophotometric determination of trace sulfate in water Analytical Chemistry. 50: 1793-1795. DOI: 10.1021/Ac50035A020  0.538
1978 Dasgupta PK, West PW. A ring oven method for the determination of sulfate at nanogram levels Mikrochimica Acta. 70: 505-510. DOI: 10.1007/Bf01197102  0.575
1977 Dasgupta P, Lundquist G, Reiszner K, West P. Synthesis and application of perimidinylammonium bromide Analytica Chimica Acta. 94: 205-207. DOI: 10.1016/S0003-2670(01)83651-5  0.502
Show low-probability matches.