Year |
Citation |
Score |
2020 |
Murtha N, Mason A, Bowen C, Clarke S, Rioux J, Beyea S. Evaluation of Golden-Angle-Sampled Dynamic Contrast-Enhanced MRI Reconstruction Using Objective Image Quality Measures: A Simulated Phantom Study. Tomography (Ann Arbor, Mich.). 6: 362-372. PMID 33364426 DOI: 10.18383/j.tom.2020.00045 |
0.314 |
|
2020 |
Rioux JA, Hewlett M, Davis C, Bowen CV, Brewer K, Clarke SE, Beyea SD. Mapping of fatty acid composition with free-breathing MR spectroscopic imaging and compressed sensing. Nmr in Biomedicine. e4241. PMID 31898379 DOI: 10.1002/Nbm.4241 |
0.318 |
|
2019 |
Mason A, Rioux J, Clarke SE, Costa A, Schmidt M, Keough V, Huynh T, Beyea S. Comparison of Objective Image Quality Metrics to Expert Radiologists' Scoring of Diagnostic Quality of MR Images. Ieee Transactions On Medical Imaging. PMID 31535985 DOI: 10.1109/Tmi.2019.2930338 |
0.434 |
|
2019 |
Lee PQ, Guida A, Patterson S, Trappenberg T, Bowen C, Beyea SD, Merrimen J, Wang C, Clarke SE. Model-free prostate cancer segmentation from dynamic contrast-enhanced MRI with recurrent convolutional networks: A feasibility study. Computerized Medical Imaging and Graphics : the Official Journal of the Computerized Medical Imaging Society. 75: 14-23. PMID 31117012 DOI: 10.1016/J.Compmedimag.2019.04.006 |
0.432 |
|
2019 |
Doucet J, Tonkopi E, Nuschke A, Tremblay M, Brewer K, Beyea S, Filiaggi M, Abraham R, Werner-Zwanziger U, Boyd D. Multi-modal imageability and degradation characteristics of high-borate glass systems for transient embolization Journal of Non-Crystalline Solids. 510: 26-35. DOI: 10.1016/J.Jnoncrysol.2019.01.014 |
0.334 |
|
2019 |
Kamintsky L, Cairns K, Beyea S, Bowen C, Veksler R, Calkin C, Friedman A. 158. Imaging Blood-Brain Barrier Pathology in Psychiatric Disorders Biological Psychiatry. 85: S65-S66. DOI: 10.1016/J.Biopsych.2019.03.172 |
0.324 |
|
2016 |
Rioux JA, Beyea SD, Bowen CV. 3D single point imaging with compressed sensing provides high temporal resolution R 2* mapping for in vivo preclinical applications. Magma (New York, N.Y.). PMID 27503309 DOI: 10.1007/S10334-016-0583-Y |
0.448 |
|
2014 |
Vema Krishna Murthy S, MacLellan M, Beyea S, Bardouille T. Faster and improved 3-D head digitization in MEG using Kinect. Frontiers in Neuroscience. 8: 326. PMID 25389382 DOI: 10.3389/Fnins.2014.00326 |
0.359 |
|
2014 |
Gawryluk JR, Mazerolle EL, Beyea SD, D'Arcy RC. Functional MRI activation in white matter during the Symbol Digit Modalities Test. Frontiers in Human Neuroscience. 8: 589. PMID 25136311 DOI: 10.3389/Fnhum.2014.00589 |
0.398 |
|
2014 |
Zhang N, Song X, Bartha R, Beyea S, D'Arcy R, Zhang Y, Rockwood K. Advances in high-field magnetic resonance spectroscopy in Alzheimer's disease Current Alzheimer Research. 11: 367-388. PMID 24597505 DOI: 10.2174/1567205011666140302200312 |
0.337 |
|
2013 |
Mazerolle EL, Gawryluk JR, Dillen KN, Patterson SA, Feindel KW, Beyea SD, Stevens MT, Newman AJ, Schmidt MH, D'Arcy RC. Sensitivity to white matter FMRI activation increases with field strength. Plos One. 8: e58130. PMID 23483983 DOI: 10.1371/Journal.Pone.0058130 |
0.38 |
|
2013 |
Holland DJ, Liu C, Song X, Mazerolle EL, Stevens MT, Sederman AJ, Gladden LF, D'Arcy RC, Bowen CV, Beyea SD. Compressed sensing reconstruction improves sensitivity of variable density spiral fMRI. Magnetic Resonance in Medicine. 70: 1634-43. PMID 23390043 DOI: 10.1002/Mrm.24621 |
0.396 |
|
2012 |
Fraser LM, Stevens MT, Beyea SD, D'Arcy RC. White versus gray matter: fMRI hemodynamic responses show similar characteristics, but differ in peak amplitude. Bmc Neuroscience. 13: 91. PMID 22852798 DOI: 10.1186/1471-2202-13-91 |
0.301 |
|
2012 |
McWhinney SR, Mazerolle EL, Gawryluk JR, Beyea SD, D'Arcy RC. Comparing gray and white matter fMRI activation using asymmetric spin echo spiral. Journal of Neuroscience Methods. 209: 351-6. PMID 22743803 DOI: 10.1016/J.Jneumeth.2012.06.014 |
0.486 |
|
2012 |
Bray JM, Filiaggi MJ, Bowen CV, Beyea SD. Degradation and drug release in calcium polyphosphate bioceramics: an MRI-based characterization. Acta Biomaterialia. 8: 3821-31. PMID 22659178 DOI: 10.1016/J.Actbio.2012.05.026 |
0.369 |
|
2012 |
Brewer KD, Rioux JA, Klassen M, Bowen CV, Beyea SD. Signal displacement in spiral-in acquisitions: simulations and implications for imaging in SFG regions. Magnetic Resonance Imaging. 30: 753-63. PMID 22503093 DOI: 10.1016/J.Mri.2012.02.014 |
0.373 |
|
2011 |
D'Arcy RC, Gawryluk JR, Beyea SD, Hajra SG, Feindel KW, Clarke DB. Tracking cognitive changes in new-onset epilepsy: functional imaging challenges. Epilepsia. 52: 43-6. PMID 21732942 DOI: 10.1111/J.1528-1167.2011.03152.X |
0.407 |
|
2011 |
Gawryluk JR, Mazerolle EL, Brewer KD, Beyea SD, D'Arcy RC. Investigation of fMRI activation in the internal capsule. Bmc Neuroscience. 12: 56. PMID 21672250 DOI: 10.1186/1471-2202-12-56 |
0.419 |
|
2011 |
Chen W, Song X, Beyea S, D'Arcy R, Zhang Y, Rockwood K. Advances in perfusion magnetic resonance imaging in Alzheimer's disease. Alzheimer's & Dementia : the Journal of the Alzheimer's Association. 7: 185-96. PMID 21074500 DOI: 10.1016/J.Jalz.2010.04.004 |
0.441 |
|
2010 |
Mazerolle EL, Beyea SD, Gawryluk JR, Brewer KD, Bowen CV, D'Arcy RC. Confirming white matter fMRI activation in the corpus callosum: co-localization with DTI tractography. Neuroimage. 50: 616-21. PMID 20053383 DOI: 10.1016/J.Neuroimage.2009.12.102 |
0.33 |
|
2009 |
Brewer KD, Rioux JA, D'Arcy RC, Bowen CV, Beyea SD. Asymmetric spin-echo (ASE) spiral improves BOLD fMRI in inhomogeneous regions. Nmr in Biomedicine. 22: 654-62. PMID 19382109 DOI: 10.1002/Nbm.1380 |
0.397 |
|
2009 |
Gawryluk JR, Brewer KD, Beyea SD, D'Arcy RC. Optimizing the detection of white matter fMRI using asymmetric spin echo spiral. Neuroimage. 45: 83-8. PMID 19084071 DOI: 10.1016/J.Neuroimage.2008.11.005 |
0.449 |
|
2009 |
Dillen K, Gawryluk J, Stevens T, Bowen C, Beyea S, Liu C, Newman A, Schmidt M, Eskes G, Stroink G, Clarke D, D'Arcy R. Characterizing the effects of magnetic field strength on specificity in functional MRI: Application in pre-surgical mapping Neuroimage. 47. DOI: 10.1016/S1053-8119(09)71595-2 |
0.35 |
|
2009 |
Gawryluk JR, D'Arcy RC, Clarke DB, Brewer KD, Beyea SD, Sadler RM, Weaver DF. Surgical planning for temporal lobe epilepsy using a multimodal imaging approach Neuroimage. 47. DOI: 10.1016/S1053-8119(09)71040-7 |
0.318 |
|
2008 |
Mazerolle EL, D'Arcy RC, Beyea SD. Detecting functional magnetic resonance imaging activation in white matter: interhemispheric transfer across the corpus callosum. Bmc Neuroscience. 9: 84. PMID 18789154 DOI: 10.1186/1471-2202-9-84 |
0.41 |
|
2007 |
Bray JM, Petrone C, Filiaggi M, Beyea SD. Measurement of fluid ingress into calcium polyphosphate bioceramics using nuclear magnetic resonance microscopy. Solid State Nuclear Magnetic Resonance. 32: 118-28. PMID 17996428 DOI: 10.1016/J.Ssnmr.2007.10.003 |
0.375 |
|
2007 |
Brewer KD, Osberg BL, Rioux JA, D'Arcy RCN, Stroink G, Beyea SD. Is 4.0 T MRI advantageous for current source localization of weak magnetic fields? International Congress Series. 1300: 565-569. DOI: 10.1016/j.ics.2006.12.056 |
0.343 |
|
2006 |
Beyea SD, Bremner TW, Balcom BJ. Minimization of diffusive attenuation in T2-weighted NMR images of porous solids using turboSPI. Solid State Nuclear Magnetic Resonance. 29: 267-71. PMID 16226019 DOI: 10.1016/J.Ssnmr.2005.09.002 |
0.676 |
|
2003 |
Goodyear DJ, Shea M, Beyea SD, Shah NJ, Balcom BJ. Single point measurements of magnetic field gradient waveform. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 163: 1-7. PMID 12852901 DOI: 10.1016/S1090-7807(03)00152-6 |
0.601 |
|
2003 |
Beyea SD, Balcom BJ, Bremner TW, Armstrong RL, Grattan-Bellew PE. Detection of Drying-Induced Microcracking in Cementitious Materials with Space-Resolved1H Nuclear Magnetic Resonance Relaxometry Journal of the American Ceramic Society. 86: 800-805. DOI: 10.1111/J.1151-2916.2003.Tb03378.X |
0.613 |
|
2003 |
Beyea SD, Caprihan A, Glass SJ, DiGiovanni A. Nondestructive characterization of nanopore microstructure: Spatially resolved Brunauer-Emmett-Teller isotherms using nuclear magnetic resonance imaging Journal of Applied Physics. 94: 935-941. DOI: 10.1063/1.1581348 |
0.386 |
|
2003 |
Balcom BJ, Barrita JC, Choi C, Beyea SD, Goodyear DJ, Bremner TW. Single-point magnetic resonance imaging (MRI) of cement based materials Materials and Structures. 36: 166-182. DOI: 10.1007/Bf02481628 |
0.683 |
|
2000 |
Beyea SD, Balcom BJ, Mastikhin IV, Bremner TW, Armstrong RL, Grattan-Bellew PE. Imaging of heterogeneous materials with a turbo spin echo single-point imaging technique. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 144: 255-65. PMID 10828193 DOI: 10.1006/Jmre.2000.2054 |
0.674 |
|
2000 |
Choi C, Balcom BJ, Beyea SD, Bremner TW, Grattan-Bellew PE, Armstrong RL. Spatially resolved pore-size distribution of drying concrete with magnetic resonance imaging Journal of Applied Physics. 88: 3578-3581. DOI: 10.1063/1.1289217 |
0.608 |
|
1998 |
Beyea SD, Balcom BJ, Bremner TW, Prado PJ, Cross AR, Armstrong RL, Grattan-Bellew PE. The influence of shrinkage-cracking on the drying behaviour of White Portland cement using Single-Point Imaging (SPI). Solid State Nuclear Magnetic Resonance. 13: 93-100. PMID 9875607 DOI: 10.1016/S0926-2040(98)00080-0 |
0.577 |
|
1998 |
Prado PJ, Balcom BJ, Beyea SD, Armstrong RL, Bremner TW, Grattan-Bellew PE. Concrete/mortar water phase transition studied by single-point MRI methods. Magnetic Resonance Imaging. 16: 521-3. PMID 9803901 DOI: 10.1016/S0730-725X(98)00062-9 |
0.664 |
|
1998 |
Beyea SD, Balcom BJ, Prado PJ, Cross AR, Kennedy CB, Armstrong RL, Bremner TW. Relaxation time mapping of short T*2 nuclei with single-point imaging (SPI) methods. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 135: 156-64. PMID 9799689 DOI: 10.1006/Jmre.1998.1537 |
0.659 |
|
1998 |
Prado PJ, Balcom BJ, Beyea SD, Bremner TW, Armstrong RL, Pishe R, Gratten-Bellew PE. Spatially resolved relaxometry and pore size distribution by single-point MRI methods: porous media calorimetry Journal of Physics D: Applied Physics. 31: 2040-2050. DOI: 10.1088/0022-3727/31/16/014 |
0.661 |
|
1998 |
Beyea S, Balcom B, Bremner T, Prado P, Green D, Armstrong R, Grattan-Bellew P. Magnetic Resonance Imaging and Moisture Content Profiles of Drying Concrete Cement and Concrete Research. 28: 453-463. DOI: 10.1016/S0008-8846(98)00009-X |
0.712 |
|
1998 |
Prado P, Balcom B, Beyea S, Bremner T, Armstrong R, Grattan-Bellew P. Concrete Freeze/Thaw as Studied by Magnetic Resonance Imaging Cement and Concrete Research. 28: 261-270. DOI: 10.1016/S0008-8846(97)00222-6 |
0.677 |
|
1997 |
Prado PJ, Balcom BJ, Beyea SD, Armstrong RL, Bremner TW. Concrete thawing studied by single-point ramped imaging. Solid State Nuclear Magnetic Resonance. 10: 1-8. PMID 9472785 DOI: 10.1016/S0926-2040(97)00071-4 |
0.662 |
|
1996 |
Balcom BJ, Macgregor RP, Beyea SD, Green DP, Armstrong RL, Bremner TW. Single-Point Ramped Imaging with T1 Enhancement (SPRITE) Journal of Magnetic Resonance. Series A. 123: 131-4. PMID 8980075 DOI: 10.1006/Jmra.1996.0225 |
0.703 |
|
Show low-probability matches. |