Paul Rullkoetter - Publications

Affiliations: 
Mechanical Engineering University of Denver, Denver, CO, United States 
Area:
Mechanical Engineering, Biomechanics Biophysics

97 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2021 Chen X, Myers CA, Clary CW, DeWall RJ, Fritz B, Blauth M, Rullkoetter PJ. Development of axial compression and combined axial compression and torque loading configurations to reproduce strain in the implanted femur during activities of daily living. Journal of Biomechanics. 120: 110363. PMID 33725522 DOI: 10.1016/j.jbiomech.2021.110363  0.52
2021 Yang H, Bayoglu R, Clary CW, Rullkoetter PJ. Impact of surgical alignment, tray material, PCL condition, and patient anatomy on tibial strains after TKA. Medical Engineering & Physics. 88: 69-77. PMID 33485516 DOI: 10.1016/j.medengphy.2021.01.001  0.52
2020 Huff DN, Myers CA, Rullkoetter PJ. Impact of alignment and kinematic variation on resistive moment and dislocation propensity for THA with lipped and neutral liners. Biomechanics and Modeling in Mechanobiology. PMID 32562094 DOI: 10.1007/s10237-020-01359-8  0.32
2020 Myers CA, Fitzpatrick CK, Huff DN, Laz PJ, Rullkoetter PJ. Development and calibration of a probabilistic finite element hip capsule representation. Computer Methods in Biomechanics and Biomedical Engineering. 1-10. PMID 32432892 DOI: 10.1080/10255842.2020.1764543  0.8
2020 Yang H, Bayoglu R, Renani MS, Behnam Y, Navacchia A, Clary C, Rullkoetter PJ. Validation and sensitivity of model-predicted proximal tibial displacement and tray micromotion in cementless total knee arthroplasty under physiological loading conditions. Journal of the Mechanical Behavior of Biomedical Materials. 109: 103793. PMID 32347217 DOI: 10.1016/J.Jmbbm.2020.103793  0.36
2020 Ali AA, Clary CW, Smoger LM, Dennis DA, Fitzpatrick CK, Rullkoetter PJ, Laz PJ. Computational framework for population-based evaluation of TKR-implanted patellofemoral joint mechanics. Biomechanics and Modeling in Mechanobiology. PMID 32020408 DOI: 10.1007/S10237-020-01295-7  0.8
2019 Alvarez O, Steensen RN, Rullkoetter PJ, Fitzpatrick CK. A computational approach to correcting joint instability in patients with recurrent patellar dislocation. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. PMID 31736122 DOI: 10.1002/jor.24526  0.64
2019 Gibbons KD, Clary CW, Rullkoetter PJ, Fitzpatrick CK. Development of a statistical shape-function model of the implanted knee for real-time prediction of joint mechanics. Journal of Biomechanics. PMID 30928205 DOI: 10.1016/J.Jbiomech.2019.03.010  0.64
2019 Mannen EM, Ali AA, Dennis DA, Haas BD, Rullkoetter PJ, Shelburne KB. Influence of Component Geometry on Patellar Mechanics in Posterior-Stabilized Rotating Platform Total Knee Arthroplasty. The Journal of Arthroplasty. PMID 30777625 DOI: 10.1016/J.Arth.2019.01.013  0.4
2019 Awadalla M, Al-Dirini RMA, O'Rourke D, Solomon LB, Heldreth M, Rullkoetter P, Taylor M. Influence of stems and metaphyseal sleeve on primary stability of cementless revision tibial trays used to reconstruct AORI IIB defects. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. PMID 30677164 DOI: 10.1002/Jor.24232  0.32
2019 Awadalla M, Al-Dirini RMA, O'Rourke D, Solomon LB, Heldreth M, Rullkoetter P, Taylor M. Influence of stems and metaphyseal sleeve on primary stability of cementless revision tibial trays used to reconstruct AORI IIB defects. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. PMID 30677164 DOI: 10.1002/Jor.24232  0.32
2018 Navacchia A, Clary CW, Han X, Shelburne KB, Wright AP, Rullkoetter PJ. Loading and kinematic profiles for patellofemoral durability testing. Journal of the Mechanical Behavior of Biomedical Materials. 86: 305-313. PMID 30006279 DOI: 10.1016/J.Jmbbm.2018.06.035  0.52
2018 Navacchia A, Clary CW, Wilson HL, Behnam YA, Rullkoetter PJ. Validation of model-predicted tibial tray-synthetic bone relative motion in cementless total knee replacement during activities of daily living. Journal of Biomechanics. PMID 30006236 DOI: 10.1016/J.Jbiomech.2018.06.024  0.52
2018 Myers CA, Laz PJ, Shelburne KB, Judd DL, Huff DN, Winters JD, Stevens-Lapsley JE, Rullkoetter PJ. The impact of hip implant alignment on muscle and joint loading during dynamic activities. Clinical Biomechanics (Bristol, Avon). 53: 93-100. PMID 29482087 DOI: 10.1016/J.Clinbiomech.2018.02.010  0.8
2018 Ali AA, Mannen EM, Rullkoetter PJ, Shelburne KB. In Vivo Comparison of Medialized Dome and Anatomic Patellofemoral Geometries using Subject-specific Computational Modeling. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. PMID 29411900 DOI: 10.1002/Jor.23865  0.4
2018 Hollenbeck JFM, Cain CM, Fattor JA, Rullkoetter PJ, Laz PJ. Statistical shape modeling characterizes three-dimensional shape and alignment variability in the lumbar spine. Journal of Biomechanics. PMID 29402403 DOI: 10.1016/J.Jbiomech.2018.01.020  0.8
2018 Sintini I, Fitzpatrick CK, Clary CW, Castelli VP, Rullkoetter PJ. Computational evaluation of TKR stability using feedback-controlled compressive loading. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. PMID 29393547 DOI: 10.1002/Jor.23862  0.64
2017 Coombs DJ, Rullkoetter PJ, Laz PJ. Efficient probabilistic finite element analysis of a lumbar motion segment. Journal of Biomechanics. PMID 28733037 DOI: 10.1016/J.Jbiomech.2017.07.002  0.8
2017 Smoger LM, Shelburne KB, Cyr AJ, Rullkoetter PJ, Laz PJ. Statistical shape modeling predicts patellar bone geometry to enable stereo-radiographic kinematic tracking. Journal of Biomechanics. PMID 28554493 DOI: 10.1016/J.Jbiomech.2017.05.009  0.8
2017 Ali AA, Harris MD, Shalhoub S, Maletsky LP, Rullkoetter PJ, Shelburne KB. Combined measurement and modeling of specimen-specific knee mechanics for healthy and ACL-deficient conditions. Journal of Biomechanics. PMID 28457606 DOI: 10.1016/J.Jbiomech.2017.04.008  0.52
2016 Rullkoetter PJ, Fitzpatrick CK, Clary CW. How Can We Use Computational Modeling to Improve Total Knee Arthroplasty?: Modeling Stability and Mobility in the Implanted Knee. The Journal of the American Academy of Orthopaedic Surgeons. PMID 27997412 DOI: 10.5435/Jaaos-D-16-00640  0.64
2016 Fitzpatrick CK, Maag C, Clary CW, Metcalfe A, Langhorn J, Rullkoetter PJ. Validation of a new computational 6-DOF knee simulator during dynamic activities. Journal of Biomechanics. PMID 27545078 DOI: 10.1016/J.Jbiomech.2016.07.040  0.64
2016 Harris MD, Cyr AJ, Ali AA, Fitzpatrick CK, Rullkoetter PJ, Maletsky LP, Shelburne KB. A Combined Experimental and Computational Approach to Subject-Specific Analysis of Knee Joint Laxity. Journal of Biomechanical Engineering. PMID 27306137 DOI: 10.1115/1.4033882  1
2016 Campbell JQ, Coombs DJ, Rao M, Rullkoetter PJ, Petrella AJ. Automated finite element meshing of the lumbar spine: Verification and validation with 18 specimen-specific models. Journal of Biomechanics. PMID 27291694 DOI: 10.1016/J.Jbiomech.2016.05.025  0.8
2016 Fattor JA, Hollenbeck JF, Laz PJ, Rullkoetter PJ, Burger EL, Patel VV, Cain CM. Patient-Specific Templating of Lumbar Total Disk Replacement to Restore Normal Anatomy and Function. Orthopedics. 39: 97-102. PMID 27023417 DOI: 10.3928/01477447-20160304-06  1
2016 Navacchia A, Rullkoetter PJ, Schütz P, List RB, Fitzpatrick CK, Shelburne KB. Subject-specific modeling of muscle force and knee contact in total knee arthroplasty. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. PMID 26792665 DOI: 10.1002/jor.23171  1
2015 Ali AA, Shalhoub SS, Cyr AJ, Fitzpatrick CK, Maletsky LP, Rullkoetter PJ, Shelburne KB. Validation of predicted patellofemoral mechanics in a finite element model of the healthy and cruciate-deficient knee. Journal of Biomechanics. PMID 26742720 DOI: 10.1016/J.Jbiomech.2015.12.020  1
2015 Navacchia A, Myers C, Rullkoetter PJ, Shelburne KB. Prediction of in vivo knee joint loads using a global probabilistic analysis. Journal of Biomechanical Engineering. PMID 26720096 DOI: 10.1115/1.4032379  1
2015 Berahmani S, Janssen D, Wolfson D, de Waal Malefijt M, Fitzpatrick CK, Rullkoetter PJ, Verdonschot1 N. An FE analysis of the effects of simplifications in experimental testing on micromotions of uncemented femoral knee implants. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. PMID 26488795 DOI: 10.1002/jor.23074  1
2015 Fitzpatrick CK, Steensen RN, Tumuluri A, Trinh T, Bentley J, Rullkoetter PJ. Computational analysis of factors contributing to patellar dislocation. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. PMID 26331373 DOI: 10.1002/jor.23041  1
2015 Smoger LM, Fitzpatrick CK, Clary CW, Cyr AJ, Maletsky LP, Rullkoetter PJ, Laz PJ. Statistical modeling to characterize relationships between knee anatomy and kinematics. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 33: 1620-30. PMID 25991502 DOI: 10.1002/Jor.22948  1
2015 Ivester JC, Cyr AJ, Harris MD, Kulis MJ, Rullkoetter PJ, Shelburne KB. A reconfigurable high-speed Stereo-Radiography system for sub-millimeter measurement of in vivo joint kinematics Journal of Medical Devices, Transactions of the Asme. 9. DOI: 10.1115/1.4030778  1
2014 Fitzpatrick CK, Rullkoetter PJ. Estimating total knee replacement joint load ratios from kinematics. Journal of Biomechanics. 47: 3003-11. PMID 25092535 DOI: 10.1016/j.jbiomech.2014.07.002  1
2014 Fitzpatrick CK, Komistek RD, Rullkoetter PJ. Developing simulations to reproduce in vivo fluoroscopy kinematics in total knee replacement patients. Journal of Biomechanics. 47: 2398-405. PMID 24845696 DOI: 10.1016/j.jbiomech.2014.04.024  1
2014 Abo-Alhol TR, Fitzpatrick CK, Clary CW, Cyr AJ, Maletsky LP, Laz PJ, Rullkoetter PJ. Patellar mechanics during simulated kneeling in the natural and implanted knee. Journal of Biomechanics. 47: 1045-51. PMID 24485512 DOI: 10.1016/J.Jbiomech.2013.12.040  1
2014 Ali AA, Cristofolini L, Schileo E, Hu H, Taddei F, Kim RH, Rullkoetter PJ, Laz PJ. Specimen-specific modeling of hip fracture pattern and repair. Journal of Biomechanics. 47: 536-43. PMID 24275435 DOI: 10.1016/J.Jbiomech.2013.10.033  1
2014 Fitzpatrick CK, Baldwin MA, Clary CW, Maletsky LP, Rullkoetter PJ. Evaluating knee replacement mechanics during ADL with PID-controlled dynamic finite element analysis. Computer Methods in Biomechanics and Biomedical Engineering. 17: 360-9. PMID 22687046 DOI: 10.1080/10255842.2012.684242  1
2013 Rao C, Fitzpatrick CK, Rullkoetter PJ, Maletsky LP, Kim RH, Laz PJ. A statistical finite element model of the knee accounting for shape and alignment variability. Medical Engineering & Physics. 35: 1450-6. PMID 23647862 DOI: 10.1016/J.Medengphy.2013.03.021  1
2013 Fitzpatrick CK, Kim RH, Ali AA, Smoger LM, Rullkoetter PJ. Effects of resection thickness on mechanics of resurfaced patellae. Journal of Biomechanics. 46: 1568-75. PMID 23623313 DOI: 10.1016/j.jbiomech.2013.03.016  1
2013 Fitzpatrick CK, Clary CW, Cyr AJ, Maletsky LP, Rullkoetter PJ. Mechanics of post-cam engagement during simulated dynamic activity. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 31: 1438-46. PMID 23606458 DOI: 10.1002/Jor.22366  1
2013 Clary CW, Fitzpatrick CK, Maletsky LP, Rullkoetter PJ. The influence of total knee arthroplasty geometry on mid-flexion stability: an experimental and finite element study. Journal of Biomechanics. 46: 1351-7. PMID 23499227 DOI: 10.1016/J.Jbiomech.2013.01.025  1
2013 Hollenbeck JFM, Rullkoetter PJ, Cain C, Fitzpatrick CK, Laz PJ. Statistical shape and alignment modeling of the lumbar spine Asme 2013 Summer Bioengineering Conference, Sbc 2013. 1. DOI: 10.1115/SBC2013-14337  1
2013 Coombs D, Bushelow M, Laz P, Rao M, Rullkoetter P. Stepwise validated finite element model of the human lumbar spine Asme 2013 Conference On Frontiers in Medical Devices: Applications of Computer Modeling and Simulation, Fmd 2013. DOI: 10.1115/FMD2013-16167  1
2012 Fitzpatrick CK, Rullkoetter PJ. Influence of patellofemoral articular geometry and material on mechanics of the unresurfaced patella. Journal of Biomechanics. 45: 1909-15. PMID 22727469 DOI: 10.1016/j.jbiomech.2012.05.028  1
2012 Fitzpatrick CK, Clary CW, Rullkoetter PJ. The role of patient, surgical, and implant design variation in total knee replacement performance. Journal of Biomechanics. 45: 2092-102. PMID 22727219 DOI: 10.1016/J.Jbiomech.2012.05.035  1
2012 Fitzpatrick CK, Clary CW, Laz PJ, Rullkoetter PJ. Relative contributions of design, alignment, and loading variability in knee replacement mechanics. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 30: 2015-24. PMID 22696429 DOI: 10.1002/Jor.22169  1
2012 Fitzpatrick CK, Baldwin MA, Clary CW, Wright A, Laz PJ, Rullkoetter PJ. Identifying alignment parameters affecting implanted patellofemoral mechanics. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 30: 1167-75. PMID 22570224 DOI: 10.1002/Jor.22055  1
2012 Hoops HE, Johnson DR, Kim RH, Dennis DA, Baldwin MA, Fitzpatrick CK, Laz PJ, Rullkoetter PJ. Control-matched computational evaluation of tendo-femoral contact in patients with posterior-stabilized total knee arthroplasty. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 30: 1355-61. PMID 22298203 DOI: 10.1002/Jor.22060  1
2012 Baldwin MA, Clary CW, Fitzpatrick CK, Deacy JS, Maletsky LP, Rullkoetter PJ. Dynamic finite element knee simulation for evaluation of knee replacement mechanics. Journal of Biomechanics. 45: 474-83. PMID 22209313 DOI: 10.1016/J.Jbiomech.2011.11.052  1
2012 Petrella AJ, Armstrong JR, Laz PJ, Rullkoetter PJ. A novel cross-shear metric for application in computer simulation of ultra-high molecular weight polyethylene wear. Computer Methods in Biomechanics and Biomedical Engineering. 15: 1223-32. PMID 22136186 DOI: 10.1080/10255842.2011.585975  1
2012 Heldreth M, Deffenbaugh DL, Reber E, Rullkoetter P. Open-sided tibial tray to poly insert interface does not generate peripheral fluid flow under cyclic loading Asme 2012 Summer Bioengineering Conference, Sbc 2012. 999-1000. DOI: 10.1115/SBC2012-80498  1
2011 Fitzpatrick CK, Baldwin MA, Laz PJ, FitzPatrick DP, Lerner AL, Rullkoetter PJ. Development of a statistical shape model of the patellofemoral joint for investigating relationships between shape and function. Journal of Biomechanics. 44: 2446-52. PMID 21803359 DOI: 10.1016/J.Jbiomech.2011.06.025  1
2011 Fitzpatrick CK, Baldwin MA, Ali AA, Laz PJ, Rullkoetter PJ. Comparison of patellar bone strain in the natural and implanted knee during simulated deep flexion. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 29: 232-9. PMID 20830739 DOI: 10.1002/Jor.21211  1
2011 Fitzpatrick CK, Baldwin MA, Rullkoetter PJ, Laz PJ. Combined probabilistic and principal component analysis approach for multivariate sensitivity evaluation and application to implanted patellofemoral mechanics. Journal of Biomechanics. 44: 13-21. PMID 20825941 DOI: 10.1016/J.Jbiomech.2010.08.016  1
2011 Pal S, Mahfouz MR, Komistek RD, Rullkoetter PJ. Comparison of in vivo contact positions for PS and PCR TKA implants using Lowest Point and full-contact techniques International Journal of Biomedical Engineering and Technology. 5: 229-246. DOI: 10.1504/Ijbet.2011.039200  1
2010 Fitzpatrick CK, Baldwin MA, Rullkoetter PJ. Computationally efficient finite element evaluation of natural patellofemoral mechanics. Journal of Biomechanical Engineering. 132: 121013. PMID 21142327 DOI: 10.1115/1.4002854  1
2010 Halloran JP, Clary CW, Maletsky LP, Taylor M, Petrella AJ, Rullkoetter PJ. Verification of predicted knee replacement kinematics during simulated gait in the Kansas knee simulator. Journal of Biomechanical Engineering. 132: 081010. PMID 20670059 DOI: 10.1115/1.4001678  1
2010 Baldwin MA, Langenderfer JE, Rullkoetter PJ, Laz PJ. Development of subject-specific and statistical shape models of the knee using an efficient segmentation and mesh-morphing approach. Computer Methods and Programs in Biomedicine. 97: 232-40. PMID 19695732 DOI: 10.1016/J.Cmpb.2009.07.005  1
2010 Deacy JS, Rao M, Smith S, Petrella AJ, Laz PJ, Rullkoetter PJ. Combined rigid-deformable modeling of lumbar spine mechanics Asme 2010 Summer Bioengineering Conference, Sbc 2010. 701-702. DOI: 10.1115/SBC2010-19672  1
2010 Armstrong JR, Laz PJ, Rullkoetter PJ, Petrella AJ. A generalized cross-shear wear algorithm based on a novel modification to archard's law Asme 2010 Summer Bioengineering Conference, Sbc 2010. 745-746. DOI: 10.1115/SBC2010-19654  1
2009 Baldwin MA, Clary C, Maletsky LP, Rullkoetter PJ. Verification of predicted specimen-specific natural and implanted patellofemoral kinematics during simulated deep knee bend. Journal of Biomechanics. 42: 2341-8. PMID 19720376 DOI: 10.1016/J.Jbiomech.2009.06.028  1
2009 Baldwin MA, Laz PJ, Stowe JQ, Rullkoetter PJ. Efficient probabilistic representation of tibiofemoral soft tissue constraint. Computer Methods in Biomechanics and Biomedical Engineering. 12: 651-9. PMID 19370459 DOI: 10.1080/10255840902822550  1
2009 Langenderfer JE, Rullkoetter PJ, Mell AG, Laz PJ. A multi-subject evaluation of uncertainty in anatomical landmark location on shoulder kinematic description. Computer Methods in Biomechanics and Biomedical Engineering. 12: 211-6. PMID 19021031 DOI: 10.1080/10255840802372094  1
2009 Petrella AJ, Stowe JQ, D'Lima DD, Rullkoetter PJ, Laz PJ. Computer-assisted versus manual alignment in THA: a probabilistic approach to range of motion. Clinical Orthopaedics and Related Research. 467: 50-5. PMID 18941857 DOI: 10.1007/S11999-008-0561-4  1
2009 Baldwin MA, Clary CW, Maletsky LP, Rullkoetter PJ. Specimen-specific verification of predicted TKR mechanics during simulated deep flexion loading conditions Proceedings of the Asme Summer Bioengineering Conference, Sbc2008. 819-820.  1
2008 Langenderfer JE, Laz PJ, Petrella AJ, Rullkoetter PJ. An efficient probabilistic methodology for incorporating uncertainty in body segment parameters and anatomical landmarks in joint loadings estimated from inverse dynamics. Journal of Biomechanical Engineering. 130: 014502. PMID 18298193 DOI: 10.1115/1.2838037  1
2008 Pal S, Haider H, Laz PJ, Knight LA, Rullkoetter PJ. Probabilistic computational modeling of total knee replacement wear Wear. 264: 701-707. DOI: 10.1016/J.Wear.2007.06.010  1
2007 Adams CR, Baldwin MA, Laz PJ, Rullkoetter PJ, Langenderfer JE. Effects of rotator cuff tears on muscle moment arms: a computational study. Journal of Biomechanics. 40: 3373-80. PMID 17597135 DOI: 10.1016/J.Jbiomech.2007.05.017  1
2007 Pal S, Langenderfer JE, Stowe JQ, Laz PJ, Petrella AJ, Rullkoetter PJ. Probabilistic modeling of knee muscle moment arms: effects of methods, origin-insertion, and kinematic variability. Annals of Biomedical Engineering. 35: 1632-42. PMID 17546504 DOI: 10.1007/S10439-007-9334-6  1
2007 Laz PJ, Stowe JQ, Baldwin MA, Petrella AJ, Rullkoetter PJ. Incorporating uncertainty in mechanical properties for finite element-based evaluation of bone mechanics. Journal of Biomechanics. 40: 2831-6. PMID 17475268 DOI: 10.1016/J.Jbiomech.2007.03.013  1
2007 Easley SK, Pal S, Tomaszewski PR, Petrella AJ, Rullkoetter PJ, Laz PJ. Finite element-based probabilistic analysis tool for orthopaedic applications. Computer Methods and Programs in Biomedicine. 85: 32-40. PMID 17084937 DOI: 10.1016/J.Cmpb.2006.09.013  1
2007 Knight LA, Pal S, Coleman JC, Bronson F, Haider H, Levine DL, Taylor M, Rullkoetter PJ. Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading. Journal of Biomechanics. 40: 1550-8. PMID 17084405 DOI: 10.1016/J.Jbiomech.2006.07.027  1
2007 Baldwin MA, Rullkoetter PJ. Computationally efficient, explicit finite element model for evaluation of patellofemoral mechanics Proceedings of the Asme Summer Bioengineering Conference 2007, Sbc 2007. 389-390.  1
2007 Baldwin MA, Langenderfer JE, Farr J, Rullkoetter PJ. Computational simulation of anterior-medial tibial tuberosity transfer: Optimization with simulated annealing Proceedings of the Asme Summer Bioengineering Conference 2007, Sbc 2007. 377-378.  1
2007 Adams CR, Baldwin MA, Laz PJ, Rullkoetter PJ, Langenderfer JE. Development of a computational model to study effects of rotator cuff tear size and location on muscle moment arms Proceedings of the Asme Summer Bioengineering Conference 2007, Sbc 2007. 373-374.  1
2006 Laz PJ, Pal S, Fields A, Petrella AJ, Rullkoetter PJ. Effects of knee simulator loading and alignment variability on predicted implant mechanics: a probabilistic study. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 24: 2212-21. PMID 17004268 DOI: 10.1002/Jor.20254  1
2006 Penmetsa JR, Laz PJ, Petrella AJ, Rullkoetter PJ. Influence of polyethylene creep behavior on wear in total hip arthroplasty. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 24: 422-7. PMID 16479600 DOI: 10.1002/Jor.20042  1
2006 Laz PJ, Pal S, Halloran JP, Petrella AJ, Rullkoetter PJ. Probabilistic finite element prediction of knee wear simulator mechanics. Journal of Biomechanics. 39: 2303-10. PMID 16185700 DOI: 10.1016/J.Jbiomech.2005.07.029  1
2005 Halloran JP, Easley SK, Petrella AJ, Rullkoetter PJ. Comparison of deformable and elastic foundation finite element simulations for predicting knee replacement mechanics. Journal of Biomechanical Engineering. 127: 813-8. PMID 16248311 DOI: 10.1115/1.1992522  1
2005 Bevill SL, Bevill GR, Penmetsa JR, Petrella AJ, Rullkoetter PJ. Finite element simulation of early creep and wear in total hip arthroplasty. Journal of Biomechanics. 38: 2365-74. PMID 16214484 DOI: 10.1016/j.jbiomech.2004.10.022  1
2005 Werner FW, Ayers DC, Maletsky LP, Rullkoetter PJ. The effect of valgus/varus malalignment on load distribution in total knee replacements. Journal of Biomechanics. 38: 349-55. PMID 15598463 DOI: 10.1016/J.Jbiomech.2004.02.024  1
2005 Halloran JP, Petrella AJ, Rullkoetter PJ. Explicit finite element modeling of total knee replacement mechanics. Journal of Biomechanics. 38: 323-31. PMID 15598460 DOI: 10.1016/J.Jbiomech.2004.02.046  1
2005 Pal S, Laz PJ, Halloran JP, Petrella AJ, Rullkoetter PJ. Robustness of TKR design to alignment and environmental variability using probabilistic mechanics Proceedings of the 2005 Summer Bioengineering Conference. 2005: 373-374.  1
2005 Pal S, Laz PJ, Knight LA, Coleman JC, Levine D, Taylor M, Rullkoetter PJ. Probabilistic finite element modeling of TKR wear Proceedings of the 2005 Summer Bioengineering Conference. 2005: 1626-1627.  1
2004 DeLyser RR, Quine RW, Rullkoetter PJ, Armentrout DL. A sophomore capstone course in measurement and automated data acquisition Ieee Transactions On Education. 47: 453-458. DOI: 10.1109/TE.2004.825539  1
2004 Easley SK, Tomaszewski PR, Petrella AJ, Rullkoetter PJ, Laz PJ. Effect of dimensional variability on hip stem reliability Transactions - 7th World Biomaterials Congress. 446.  1
2003 DeLyser RR, Thompson SS, Edelstein J, Lengsfeld C, Rosa AJ, Rullkoetter P, Whitman R, Whitt M. Creating a student centered learning environment at the University of Denver Journal of Engineering Education. 92: 269-273. DOI: 10.1002/J.2168-9830.2003.Tb00768.X  1
2002 Halloran JP, Petrella AJ, Rullkoetter PJ. Development and verification of a dynamic TKR model Asme International Mechanical Engineering Congress and Exposition, Proceedings. 321-322. DOI: 10.1115/IMECE2002-33035  1
2002 DeLyser RR, Rullkoetter P, Armentrout D. A novel interdisciplinary course measurement and automated data acquisition - an update Proceedings - Frontiers in Education Conference. 3.  1
2001 DeLyser RR, Edelstein J, Lengsfeld C, Rosa AJ, Rullkoetter P, Whitman R, Whitt M, Thompson SS. Enabling effective learning, curriculum delivery reform at the University of Denver Proceedings - Frontiers in Education Conference. 3.  1
2001 Houchaime W, Petrella A, Dietz T, Halloran J, Rullkoetter P. Development of a rate-dependent material model for UHMWPE joint replacement components American Society of Mechanical Engineers, Bioengineering Division (Publication) Bed. 51: 101-102.  1
2001 Halloran JP, Rullkoetter PJ. Development of an explicit-finite-element-based total knee replacement model American Society of Mechanical Engineers, Bioengineering Division (Publication) Bed. 50: 243-244.  1
2001 Halloran JP, Rullkoetter PJ. A total knee replacement model for evaluation of joint mechanics American Society of Mechanical Engineers, Bioengineering Division (Publication) Bed. 51: 175-176.  1
1999 Rullkoetter PJ. Viscoelastic behavior of UHMWPE TKR components during compressive loading and sliding conditions American Society of Mechanical Engineers, Bioengineering Division (Publication) Bed. 43: 133-134.  1
1999 Kolb ED, Rullkoetter PJ. Effect of bone ingrowth and acetabular geometry on load transfer and distribution in total hip arthroplasty American Society of Mechanical Engineers, Bioengineering Division (Publication) Bed. 42: 661-662.  1
1999 Rullkoetter PJ, Gabriel SM, Colleran DP, Zalenski EB, Gorhan MC, Fifolt DA. Trade-offs in contact mechanics for total knee replacement design and evaluation American Society of Mechanical Engineers, Bioengineering Division (Publication) Bed. 42: 671-672.  1
1997 Sheshadri VB, Rullkoetter PJ, Hillberry BM. A method for determining the anterior-posterior motion of tibiofemoral contact during simulated gait in total knee arthroplasty American Society of Mechanical Engineers, Bioengineering Division (Publication) Bed. 36: 305-306.  1
Show low-probability matches.