Year |
Citation |
Score |
2023 |
Sinha U, Sinha S. Editorial for "Characterizing the Myoarchitecture of the Supraspinatus and Infraspinatus Muscles With MRI Using Diffusion Tensor Imaging". Journal of Magnetic Resonance Imaging : Jmri. PMID 37261813 DOI: 10.1002/jmri.28841 |
0.307 |
|
2020 |
Sinha U, Malis V, Chen JS, Csapo R, Kinugasa R, Narici MV, Sinha S. Role of the Extracellular Matrix in Loss of Muscle Force With Age and Unloading Using Magnetic Resonance Imaging, Biochemical Analysis, and Computational Models. Frontiers in Physiology. 11: 626. PMID 32625114 DOI: 10.3389/Fphys.2020.00626 |
0.421 |
|
2020 |
Sinha U, Malis V, Csapo R, Narici M, Sinha S. Magnetic resonance imaging based muscle strain rate mapping during eccentric contraction to study effects of unloading induced by unilateral limb suspension. European Journal of Translational Myology. 30: 8935. PMID 32499902 DOI: 10.4081/Ejtm.2019.8935 |
0.385 |
|
2019 |
Malis V, Sinha U, Sinha S. Compressed sensing velocity encoded phase contrast imaging: Monitoring skeletal muscle kinematics. Magnetic Resonance in Medicine. PMID 31828833 DOI: 10.1002/Mrm.28100 |
0.375 |
|
2019 |
Zhang Y, Chen JS, He Q, He X, Basava RR, Hodgson J, Sinha U, Sinha S. Microstructural analysis of skeletal muscle force generation during aging. International Journal For Numerical Methods in Biomedical Engineering. e3295. PMID 31820588 DOI: 10.1002/Cnm.3295 |
0.347 |
|
2018 |
Malis V, Sinha U, Csapo R, Narici M, Smitaman E, Sinha S. Diffusion tensor imaging and diffusion modeling: Application to monitoring changes in the medial gastrocnemius in disuse atrophy induced by unilateral limb suspension. Journal of Magnetic Resonance Imaging : Jmri. PMID 30569482 DOI: 10.1002/Jmri.26295 |
0.379 |
|
2018 |
Zifan A, Reisert M, Sinha S, Ledgerwood-Lee M, Cory E, Sah R, Mittal RK. Connectivity of the Superficial Muscles of the Human Perineum: A Diffusion Tensor Imaging-Based Global Tractography Study. Scientific Reports. 8: 17867. PMID 30552351 DOI: 10.1038/S41598-018-36099-4 |
0.405 |
|
2018 |
Bilston LE, Bolsterlee B, Nordez A, Sinha S. Contemporary image-based methods for measuring passive mechanical properties of skeletal muscles in vivo. Journal of Applied Physiology (Bethesda, Md. : 1985). PMID 30236053 DOI: 10.1152/Japplphysiol.00672.2018 |
0.392 |
|
2018 |
Franchi MV, Raiteri BJ, Longo S, Sinha S, Narici MV, Csapo R. Muscle Architecture Assessment: Strengths, Shortcomings and New Frontiers of in Vivo Imaging Techniques. Ultrasound in Medicine & Biology. PMID 30185385 DOI: 10.1016/J.Ultrasmedbio.2018.07.010 |
0.386 |
|
2018 |
Sinha U, Malis V, Csapo R, Narici M, Sinha S. Shear strain rate from phase contrast velocity encoded MRI: Application to study effects of aging in the medial gastrocnemius muscle. Journal of Magnetic Resonance Imaging : Jmri. PMID 29607567 DOI: 10.1002/Jmri.26030 |
0.339 |
|
2018 |
Sinha S, Sinha U, Malis V, Bhargava V, Sakamoto K, Rajasekaran M. Exploration of male urethral sphincter complex using diffusion tensor imaging (DTI)-based fiber-tracking. Journal of Magnetic Resonance Imaging : Jmri. PMID 29573022 DOI: 10.1002/Jmri.26017 |
0.369 |
|
2018 |
Kinugasa R, Taniguchi K, Yamamura N, Fujimiya M, Katayose M, Takagi S, Edgerton VR, Sinha S. A Multi-modality Approach Towards Elucidation of the Mechanism for Human Achilles Tendon Bending During Passive Ankle Rotation. Scientific Reports. 8: 4319. PMID 29531268 DOI: 10.1038/S41598-018-22661-7 |
0.316 |
|
2017 |
Malis V, Sinha U, Csapo R, Narici M, Sinha S. Relationship of changes in strain rate indices estimated from velocity-encoded MR imaging to loss of muscle force following disuse atrophy. Magnetic Resonance in Medicine. PMID 28560822 DOI: 10.1002/Mrm.26759 |
0.368 |
|
2017 |
Rajasekaran MR, Trivedi I, Sinha S, Bhargava V. Mp81-16 Three- Dimensional Reconstruction Of Male Pelvic Anatomy From Magnetic Resonance Imaging The Journal of Urology. 197. DOI: 10.1016/J.Juro.2017.02.2542 |
0.337 |
|
2017 |
Sakamoto K, Bhargava V, Malis V, Rajasekaran MR, Sinha S. Mp42-08 Male Urethral Sphincter Complex Revisited Using Novel Mr Imaging Techniques The Journal of Urology. 197. DOI: 10.1016/J.Juro.2017.02.1297 |
0.329 |
|
2016 |
Chen JS, Basava RR, Zhang Y, Csapo R, Malis V, Sinha U, Hodgson J, Sinha S. Pixel-based meshfree modelling of skeletal muscles. Computer Methods in Biomechanics and Biomedical Engineering. Imaging & Visualization. 4: 73-85. PMID 28748126 DOI: 10.1080/21681163.2015.1049712 |
0.417 |
|
2016 |
Ugarte V, Sinha U, Malis V, Csapo R, Sinha S. 3D multimodal spatial fuzzy segmentation of intramuscular connective and adipose tissue from ultrashort TE MR images of calf muscle. Magnetic Resonance in Medicine. PMID 26892499 DOI: 10.1002/Mrm.26156 |
0.375 |
|
2016 |
Zifan A, Sinha S, Ledgerwood MM, Mittal RK. Tu1786 Effectiveness of Quantitative Regional Diffusion Tensor Magnetic Resonance Imaging Metrics for Evaluating the Microstructural Integrity of the External Anal Sphincter Gastroenterology. 150. DOI: 10.1016/S0016-5085(16)33197-3 |
0.369 |
|
2015 |
Csapo R, Malis V, Sinha U, Sinha S. Mapping of spatial and temporal heterogeneity of plantar flexor muscle activity during isometric contraction - correlation of Velocity-Encoded MRI with EMG. Journal of Applied Physiology (Bethesda, Md. : 1985). jap.00275.2015. PMID 26112239 DOI: 10.1152/Japplphysiol.00275.2015 |
0.392 |
|
2015 |
Sinha U, Malis V, Csapo R, Moghadasi A, Kinugasa R, Sinha S. Age-related differences in strain rate tensor of the medial gastrocnemius muscle during passive plantarflexion and active isometric contraction using velocity encoded MR imaging: potential index of lateral force transmission. Magnetic Resonance in Medicine. 73: 1852-63. PMID 25046255 DOI: 10.1002/Mrm.25312 |
0.351 |
|
2015 |
Sinha U, Csapo R, Malis V, Xue Y, Sinha S. Age-related differences in diffusion tensor indices and fiber architecture in the medial and lateral gastrocnemius. Journal of Magnetic Resonance Imaging : Jmri. 41: 941-53. PMID 24771672 DOI: 10.1002/Jmri.24641 |
0.324 |
|
2015 |
Mittal RK, Ledgerwood MM, Sinha S. Sa1350 Magnetic Resonance Diffusion Tensor Imaging & Muscle Fiber Tractography Show Defects of the Transverse Perinea and Bulbospongiosus Muscles of the External Anal Sphincter Complex in Patient With Anal Incontinence Gastroenterology. 148. DOI: 10.1016/S0016-5085(15)30990-2 |
0.381 |
|
2014 |
Csapo R, Malis V, Sinha U, Du J, Sinha S. Age-associated differences in triceps surae muscle composition and strength - an MRI-based cross-sectional comparison of contractile, adipose and connective tissue. Bmc Musculoskeletal Disorders. 15: 209. PMID 24939372 DOI: 10.1186/1471-2474-15-209 |
0.346 |
|
2014 |
Csapo R, Malis V, Hodgson J, Sinha S. Age-related greater Achilles tendon compliance is not associated with larger plantar flexor muscle fascicle strains in senior women. Journal of Applied Physiology (Bethesda, Md. : 1985). 116: 961-9. PMID 24505104 DOI: 10.1152/Japplphysiol.01337.2013 |
0.352 |
|
2014 |
Mittal RK, Bhargava V, Sheean G, Ledgerwood M, Sinha S. Purse-string morphology of external anal sphincter revealed by novel imaging techniques. American Journal of Physiology. Gastrointestinal and Liver Physiology. 306: G505-14. PMID 24458022 DOI: 10.1152/Ajpgi.00338.2013 |
0.402 |
|
2014 |
Kinugasa R, Hodgson JA, Edgerton VR, Sinha S. Uncover the identity of obstruction on the Achilles tendon Journal of Foot and Ankle Research. 7. DOI: 10.1186/1757-1146-7-S1-A43 |
0.327 |
|
2014 |
Ledgerwood MM, Sinha S, Mittal RK. Mo1998 Magnetic Resonance Diffuse Tensor Imaging Based Muscle Fiber Tracking Confirms the “Purse String” Nature of the External Anal Sphincter Gastroenterology. 146. DOI: 10.1016/S0016-5085(14)62587-7 |
0.391 |
|
2013 |
Kinugasa R, Oda T, Komatsu T, Edgerton VR, Sinha S. Interaponeurosis shear strain modulates behavior of myotendinous junction of the human triceps surae. Physiological Reports. 1: e00147. PMID 24400149 DOI: 10.1002/Phy2.147 |
0.325 |
|
2013 |
Csapo R, Hodgson J, Kinugasa R, Edgerton VR, Sinha S. Ankle morphology amplifies calcaneus movement relative to triceps surae muscle shortening. Journal of Applied Physiology (Bethesda, Md. : 1985). 115: 468-73. PMID 23743400 DOI: 10.1152/Japplphysiol.00395.2013 |
0.361 |
|
2013 |
Ledgerwood M, Sinha S, Gupta A, Bhargava V, Mittal RK. Mo1231 Magnetic Resonance Diffusion Tensor Imaging of the Anatomically Disrupted External Anal Sphincter: Comparison With Normal Gastroenterology. 144. DOI: 10.1016/S0016-5085(13)62264-7 |
0.374 |
|
2012 |
Hodgson JA, Chi SW, Yang JP, Chen JS, Edgerton VR, Sinha S. Finite element modeling of passive material influence on the deformation and force output of skeletal muscle. Journal of the Mechanical Behavior of Biomedical Materials. 9: 163-83. PMID 22498294 DOI: 10.1016/J.Jmbbm.2012.01.010 |
0.335 |
|
2012 |
Sinha S, Shin DD, Hodgson JA, Kinugasa R, Edgerton VR. Computer-controlled, MR-compatible foot-pedal device to study dynamics of the muscle tendon complex under isometric, concentric, and eccentric contractions. Journal of Magnetic Resonance Imaging : Jmri. 36: 498-504. PMID 22392816 DOI: 10.1002/Jmri.23617 |
0.635 |
|
2012 |
Kinugasa R, Hodgson JA, Edgerton VR, Sinha S. Asymmetric deformation of contracting human gastrocnemius muscle. Journal of Applied Physiology (Bethesda, Md. : 1985). 112: 463-70. PMID 22134691 DOI: 10.1152/Japplphysiol.00666.2011 |
0.357 |
|
2011 |
Kinugasa R, Kawakami Y, Sinha S, Fukunaga T. Unique spatial distribution of in vivo human muscle activation. Experimental Physiology. 96: 938-48. PMID 21666032 DOI: 10.1113/Expphysiol.2011.057562 |
0.389 |
|
2011 |
Sinha S, Sinha U. Reproducibility analysis of diffusion tensor indices and fiber architecture of human calf muscles in vivo at 1.5 Tesla in neutral and plantarflexed ankle positions at rest Journal of Magnetic Resonance Imaging. 34: 107-119. PMID 21608064 DOI: 10.1002/Jmri.22596 |
0.361 |
|
2011 |
Yan RT, Bluemke D, Gomes A, Burke G, Shea S, Liu K, Bahrami H, Sinha S, Wu C, Fernandes V, McClelland R, Lima JA. Regional left ventricular myocardial dysfunction as a predictor of incident cardiovascular events MESA (multi-ethnic study of atherosclerosis). Journal of the American College of Cardiology. 57: 1735-44. PMID 21511109 DOI: 10.1016/J.Jacc.2010.10.060 |
0.314 |
|
2011 |
Sinha U, Sinha S, Hodgson JA, Edgerton RV. Human soleus muscle architecture at different ankle joint angles from magnetic resonance diffusion tensor imaging Journal of Applied Physiology. 110: 807-819. PMID 21164150 DOI: 10.1152/Japplphysiol.00923.2010 |
0.371 |
|
2011 |
Sinha S, Bhargava V, Mittal RK. Circular Versus the “Purse String” Morphology of External Anal Sphincter Muscle – An Ultrasound, Magnetic Resonance Imaging and Diffusion Tensor Imaging Study Gastroenterology. 140. DOI: 10.1016/S0016-5085(11)63294-0 |
0.384 |
|
2010 |
Kinugasa R, Hodgson JA, Edgerton VR, Shin DD, Sinha S. Reduction in tendon elasticity from unloading is unrelated to its hypertrophy. Journal of Applied Physiology (Bethesda, Md. : 1985). 109: 870-7. PMID 20616227 DOI: 10.1152/Japplphysiol.00384.2010 |
0.626 |
|
2010 |
Chi SW, Hodgson J, Chen JS, Reggie Edgerton V, Shin DD, Roiz RA, Sinha S. Finite element modeling reveals complex strain mechanics in the aponeuroses of contracting skeletal muscle. Journal of Biomechanics. 43: 1243-50. PMID 20189180 DOI: 10.1016/J.Jbiomech.2010.01.005 |
0.588 |
|
2009 |
Shin DD, Hodgson JA, Edgerton VR, Sinha S. In vivo intramuscular fascicle-aponeuroses dynamics of the human medial gastrocnemius during plantarflexion and dorsiflexion of the foot. Journal of Applied Physiology (Bethesda, Md. : 1985). 107: 1276-84. PMID 19608924 DOI: 10.1152/Japplphysiol.91598.2008 |
0.621 |
|
2009 |
Sinha S, Sinha U. Recent advances in Breast MRI and MRS Nmr in Biomedicine. 22: 3-16. PMID 18654998 DOI: 10.1002/Nbm.1270 |
0.428 |
|
2008 |
Shin D, Finni T, Ahn S, Hodgson JA, Lee HD, Edgerton VR, Sinha S. In vivo estimation and repeatability of force-length relationship and stiffness of the human achilles tendon using phase contrast MRI. Journal of Magnetic Resonance Imaging : Jmri. 28: 1039-45. PMID 18821605 DOI: 10.1002/Jmri.21533 |
0.676 |
|
2008 |
Kinugasa R, Shin D, Yamauchi J, Mishra C, Hodgson JA, Edgerton VR, Sinha S. Phase-contrast MRI reveals mechanical behavior of superficial and deep aponeuroses in human medial gastrocnemius during isometric contraction. Journal of Applied Physiology (Bethesda, Md. : 1985). 105: 1312-20. PMID 18703759 DOI: 10.1152/Japplphysiol.90440.2008 |
0.614 |
|
2008 |
Shin D, Finni T, Ahn S, Hodgson JA, Lee HD, Edgerton VR, Sinha S. Effect of chronic unloading and rehabilitation on human Achilles tendon properties: a velocity-encoded phase-contrast MRI study. Journal of Applied Physiology (Bethesda, Md. : 1985). 105: 1179-86. PMID 18687975 DOI: 10.1152/Japplphysiol.90699.2008 |
0.721 |
|
2008 |
Finni T, Havu M, Sinha S, Usenius JP, Cheng S. Mechanical behavior of the quadriceps femoris muscle tendon unit during low-load contractions. Journal of Applied Physiology (Bethesda, Md. : 1985). 104: 1320-8. PMID 18339890 DOI: 10.1152/Japplphysiol.01069.2007 |
0.389 |
|
2008 |
Wen H, Dou Z, Finni T, Havu M, Kang Z, Cheng S, Sipilä S, Sinha S, Usenius JP, Cheng S. Thigh muscle function in stroke patients revealed by velocity-encoded cine phase-contrast magnetic resonance imaging. Muscle & Nerve. 37: 736-44. PMID 18335468 DOI: 10.1002/Mus.20986 |
0.34 |
|
2007 |
Ahn S, Shin D, Tateshima S, Tanishita K, Vinuela F, Sinha S. Fluid-induced wall shear stress in anthropomorphic brain aneurysm models: MR phase-contrast study at 3 T. Journal of Magnetic Resonance Imaging : Jmri. 25: 1120-30. PMID 17520716 DOI: 10.1002/Jmri.20928 |
0.693 |
|
2006 |
Vogel-Claussen J, Finn JP, Gomes AS, Hundley GW, Jerosch-Herold M, Pearson G, Sinha S, Lima JA, Bluemke DA. Left ventricular papillary muscle mass: relationship to left ventricular mass and volumes by magnetic resonance imaging. Journal of Computer Assisted Tomography. 30: 426-32. PMID 16778617 DOI: 10.1097/00004728-200605000-00013 |
0.317 |
|
2006 |
Sinha S, Sinha U, Edgerton VR. In vivo diffusion tensor imaging of the human calf muscle. Journal of Magnetic Resonance Imaging : Jmri. 24: 182-90. PMID 16729262 DOI: 10.1002/Jmri.20593 |
0.361 |
|
2006 |
Natori S, Lai S, Finn JP, Gomes AS, Hundley WG, Jerosch-Herold M, Pearson G, Sinha S, Arai A, Lima JA, Bluemke DA. Cardiovascular function in multi-ethnic study of atherosclerosis: normal values by age, sex, and ethnicity. Ajr. American Journal of Roentgenology. 186: S357-65. PMID 16714609 DOI: 10.2214/Ajr.04.1868 |
0.306 |
|
2006 |
Hodgson JA, Finni T, Lai AM, Edgerton VR, Sinha S. Influence of structure on the tissue dynamics of the human soleus muscle observed in MRI studies during isometric contractions. Journal of Morphology. 267: 584-601. PMID 16453292 DOI: 10.1002/Jmor.10421 |
0.348 |
|
2006 |
Lee HD, Finni T, Hodgson JA, Lai AM, Edgerton VR, Sinha S. Soleus aponeurosis strain distribution following chronic unloading in humans: an in vivo MR phase-contrast study. Journal of Applied Physiology (Bethesda, Md. : 1985). 100: 2004-11. PMID 16424072 DOI: 10.1152/Japplphysiol.01085.2005 |
0.346 |
|
2006 |
Edvardsen T, Rosen BD, Pan L, Jerosch-Herold M, Lai S, Hundley WG, Sinha S, Kronmal RA, Bluemke DA, Lima JA. Regional diastolic dysfunction in individuals with left ventricular hypertrophy measured by tagged magnetic resonance imaging--the Multi-Ethnic Study of Atherosclerosis (MESA). American Heart Journal. 151: 109-14. PMID 16368301 DOI: 10.1016/J.Ahj.2005.02.018 |
0.31 |
|
2006 |
Finni T, Hodgson JA, Lai AM, Edgerton VR, Sinha S. Muscle synergism during isometric plantarflexion in achilles tendon rupture patients and in normal subjects revealed by velocity-encoded cine phase-contrast MRI. Clinical Biomechanics (Bristol, Avon). 21: 67-74. PMID 16194588 DOI: 10.1016/J.Clinbiomech.2005.08.007 |
0.354 |
|
2005 |
Grinstead J, Sinha S. In-plane velocity encoding with coherent steady-state imaging. Magnetic Resonance in Medicine. 54: 138-45. PMID 15968674 DOI: 10.1002/Mrm.20526 |
0.335 |
|
2005 |
Bhidayasiri R, Bronstein JM, Sinha S, Krahl SE, Ahn S, Behnke EJ, Cohen MS, Frysinger R, Shellock FG. Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain. Magnetic Resonance Imaging. 23: 549-55. PMID 15919600 DOI: 10.1016/J.Mri.2005.02.007 |
0.6 |
|
2004 |
De Salles AA, Frighetto L, Behnke E, Sinha S, Tseng L, Torres R, Lee M, Cabatan-Awang C, Frysinger R. Functional neurosurgery in the MRI environment. Minimally Invasive Neurosurgery : Min. 47: 284-9. PMID 15578341 DOI: 10.1055/S-2004-830094 |
0.346 |
|
2004 |
Sinha S, Hodgson JA, Finni T, Lai AM, Grinstead J, Edgerton VR. Muscle kinematics during isometric contraction: development of phase contrast and spin tag techniques to study healthy and atrophied muscles. Journal of Magnetic Resonance Imaging : Jmri. 20: 1008-19. PMID 15558560 DOI: 10.1002/Jmri.20210 |
0.41 |
|
2004 |
Tateshima S, Grinstead J, Sinha S, Nien YL, Murayama Y, Villablanca JP, Tanishita K, Viñuela F. Intraaneurysmal flow visualization by using phase-contrast magnetic resonance imaging: feasibility study based on a geometrically realistic in vitro aneurysm model. Journal of Neurosurgery. 100: 1041-8. PMID 15200119 DOI: 10.3171/Jns.2004.100.6.1041 |
0.308 |
|
2003 |
Finni T, Hodgson JA, Lai AM, Edgerton VR, Sinha S. Mapping of movement in the isometrically contracting human soleus muscle reveals details of its structural and functional complexity. Journal of Applied Physiology (Bethesda, Md. : 1985). 95: 2128-33. PMID 12857769 DOI: 10.1152/Japplphysiol.00596.2003 |
0.362 |
|
2003 |
Finni T, Hodgson JA, Lai AM, Edgerton VR, Sinha S. Nonuniform strain of human soleus aponeurosis-tendon complex during submaximal voluntary contractions in vivo. Journal of Applied Physiology (Bethesda, Md. : 1985). 95: 829-37. PMID 12716873 DOI: 10.1152/Japplphysiol.00775.2002 |
0.358 |
|
2003 |
Finni T, Hodgson JA, Lai AM, Sinha S, Edgerton VR. NON-UNIFORMITY WITHIN THE TRICEPS SURAE MUSCLE-TENDON UNIT DURING SUBMAXIMAL VOLUNTARY CONTRACTIONS Medicine & Science in Sports & Exercise. 35: S384. DOI: 10.1097/00005768-200305001-02139 |
0.302 |
|
2002 |
Sinha S, Sinha U. Functional magnetic resonance of human breast tumors: diffusion and perfusion imaging. Annals of the New York Academy of Sciences. 980: 95-115. PMID 12594084 DOI: 10.1111/J.1749-6632.2002.Tb04891.X |
0.426 |
|
2002 |
Sinha S, Lucas-Quesada FA, Sinha U, DeBruhl N, Bassett LW. In vivo diffusion-weighted MRI of the breast: potential for lesion characterization. Journal of Magnetic Resonance Imaging : Jmri. 15: 693-704. PMID 12112520 DOI: 10.1002/Jmri.10116 |
0.711 |
|
2002 |
Oshiro T, Sinha U, Lu D, Sinha S. Reduction of electronic noise from radiofrequency generator during radiofrequency ablation in interventional MRI. Journal of Computer Assisted Tomography. 26: 308-16. PMID 11884792 DOI: 10.1097/00004728-200203000-00025 |
0.579 |
|
2001 |
Niyazov DM, Andrews JC, Strelioff D, Sinha S, Lufkin R. Diagnosis of endolymphatic hydrops in vivo with magnetic resonance imaging. Otology & Neurotology. 22: 813-817. PMID 11698801 DOI: 10.1097/00129492-200111000-00017 |
0.392 |
|
1999 |
Williams S, Borges A, Oshiro T, Sinha S, Sinha U, Lu D, DeBruhl N, Hall T, Curran J, Lufkin R. Magnetic Resonance Image-Guided Biopsies: A Review Seminars in Interventional Radiology. 16: 71-83. DOI: 10.1055/S-0028-1082191 |
0.605 |
|
1998 |
Lee MH, Lufkin RB, Borges A, Lu DSK, Sinha S, Farahani K, Villabalanca P, Curran J, Hall T, Atkinson D, Kangarloo H. MR-guided procedures using contemporaneous imaging frameless stereotaxis in an open-configuration system. Journal of Computer Assisted Tomography. 22: 998-1005. PMID 9843248 DOI: 10.1097/00004728-199811000-00030 |
0.347 |
|
1997 |
Sinha S, Lucas-Quesada FA, DeBruhl ND, Sayre J, Farria D, Gorczyca DP, Bassett LW. Multifeature analysis of Gd-enhanced MR images of breast lesions. Journal of Magnetic Resonance Imaging : Jmri. 7: 1016-26. PMID 9400844 DOI: 10.1002/Jmri.1880070613 |
0.723 |
|
1997 |
Sinha S, Oshiro T, Sinha U, Lufkin R. Phase imaging on a .2-T MR scanner: application to temperature monitoring during ablation procedures. Journal of Magnetic Resonance Imaging : Jmri. 7: 918-28. PMID 9307920 DOI: 10.1002/Jmri.1880070522 |
0.601 |
|
1997 |
Lu DSK, Lee H, Farahani K, Sinha S, Lufkin R. Biopsy of hepatic dome lesions : Semi-real-time coronal MR guidance technique American Journal of Roentgenology. 168: 737-739. PMID 9057526 DOI: 10.2214/Ajr.168.3.9057526 |
0.355 |
|
1996 |
Lucas-Quesada FA, Sinha U, Sinha S. Segmentation strategies for breast tumors from dynamic MR images. Journal of Magnetic Resonance Imaging : Jmri. 6: 753-63. PMID 8890013 DOI: 10.1002/Jmri.1880060508 |
0.724 |
|
1996 |
Sinha U, Sinha S. High speed diffusion imaging in the presence of eddy currents. Journal of Magnetic Resonance Imaging : Jmri. 6: 657-66. PMID 8835960 DOI: 10.1002/Jmri.1880060415 |
0.33 |
|
1996 |
Sinha S, Sinha U. Black blood dual phase turbo FLASH MR imaging of the heart. Journal of Magnetic Resonance Imaging : Jmri. 6: 484-94. PMID 8724415 DOI: 10.1002/Jmri.1880060312 |
0.343 |
|
1996 |
Farria DM, Gorczyca DP, Barsky SH, Sinha S, Bassett LW. Benign phyllodes tumor of the breast: MR imaging features. American Journal of Roentgenology. 167: 187-189. PMID 8659370 DOI: 10.2214/Ajr.167.1.8659370 |
0.385 |
|
1995 |
Sinha S, Sinha U, Czernin J, Porenta G, Schelbert HR. Noninvasive assessment of myocardial perfusion and metabolism: Feasibility of registering gated MR and PET images American Journal of Roentgenology. 164: 301-307. PMID 7839959 DOI: 10.2214/Ajr.164.2.7839959 |
0.356 |
|
1995 |
Gorczyca DP, Debruhl ND, Sullenberger PC, Farria D, Sinha S, Bassett LW. Wire Localization of Breast Lesions Before Biopsy: Use of an MR-Compatible Device in Phantoms and Cadavers American Journal of Roentgenology. 165: 835-838. PMID 7676977 DOI: 10.2214/Ajr.165.4.7676977 |
0.4 |
|
1993 |
Sinha S, Gorczyca DP, DeBruhl ND, Shellock FG, Gausche VR, Bassett LW. MR imaging of silicone breast implants: comparison of different coil arrays. Radiology. 187: 284-6. PMID 8451430 DOI: 10.1148/Radiology.187.1.8451430 |
0.383 |
|
1993 |
Anzai Y, Desalles AA, Black KL, Sinha S, Farahani K, Behnke EA, Castro DJ, Lufkin RB. Interventional MR imaging. Radiographics : a Review Publication of the Radiological Society of North America, Inc. 13: 897-904. PMID 8356275 DOI: 10.1148/Radiographics.13.4.8356275 |
0.323 |
|
1993 |
Ahn CY, Shaw WW, Narayanan K, Gorczyca DP, Sinha S, Debruhl ND, Bassett LW. Definitive diagnosis of breast implant rupture using magnetic resonance imaging. Plastic and Reconstructive Surgery. 92: 681-91. PMID 8356130 DOI: 10.1097/00006534-199309001-00018 |
0.346 |
|
1993 |
Castro DJ, Lufkin RB, Saxton RE, Ziarati M, Nyerges A, Farahani K, Sinha S, Kimme-Smith C, Schiller VL, Keen R, Anzai Y, Pushek T. New interventional room of the 1990s: how to upgrade a standard MR suite for minimally invasive surgery Proceedings of Spie. 1892: 168-175. DOI: 10.1117/12.147497 |
0.362 |
|
1993 |
Huang LJ, Sinha S, Sinha U, Ennevor SJ, Saxton RE, Lufkin RB, Castro DJ. Precision needle-tip localization during magnetic resonance imaging interstitial therapy Proceedings of Spie. 1892: 91-94. DOI: 10.1117/12.147489 |
0.349 |
|
1992 |
Sinha S, Sinha U, Kangarloo H, Huang HK. A PACS-based interactive teaching module for radiologic sciences. Ajr. American Journal of Roentgenology. 159: 199-205. PMID 1609698 DOI: 10.2214/Ajr.159.1.1609698 |
0.331 |
|
1992 |
Gorczyca DP, Sinha S, Ahn CY, DeBruhl ND, Hayes MK, Gausche VR, Shaw WW, Bassett LW. Silicone breast implants in vivo: MR imaging Radiology. 185: 407-410. PMID 1410346 DOI: 10.1148/Radiology.185.2.1410346 |
0.332 |
|
1992 |
Sinha S, Sinha U, Kangarloo H, Huang HK. Magnetic resonance image synthesis from analytic solutions of spin-echo and radio frequency-spoiled gradient-echo images. Investigative Radiology. 27: 856-64. PMID 1399443 DOI: 10.1097/00004424-199210000-00017 |
0.356 |
|
1990 |
Farahani K, Sinha U, Sinha S, Chiu LC, Lufkin RB. Effect of field strength on susceptibility artifacts in magnetic resonance imaging. Computerized Medical Imaging and Graphics. 14: 409-413. PMID 2272012 DOI: 10.1016/0895-6111(90)90040-I |
0.373 |
|
1989 |
Sinha S, Sinha U, Lufkin R, Hanafee W. Pulse sequence optimization for use with a biopsy needle in MRI Magnetic Resonance Imaging. 7: 575-579. PMID 2607909 DOI: 10.1016/0730-725X(89)90415-3 |
0.307 |
|
Show low-probability matches. |