Qizhi Hu, Ph.D. - Publications

Affiliations: 
2006 Purdue University, West Lafayette, IN, United States 
Area:
mass spectrometric instrumentation, including miniature mass spectrometers.

10 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2016 Feng G, Xiao J, Bi Y, Lan Z, Zheng X, Lu Z, Li J, Wu K, Kislauskis E, McCarthy S, Hu Q, Jiang X, Wu T, Laham R. 12-month coronary angiography, intravascular ultrasound and histology evaluation of a novel fully bioabsorbable poly-l-lactic acid/amorphous calcium phosphate scaffolds in porcine coronary arteries Journal of Biomedical Nanotechnology. 12: 743-752. DOI: 10.1166/jbn.2016.2241  0.309
2016 Zhu L, Xu G, Song Q, Tang T, Wang X, Wei F, Hu Q. Highly sensitive determination of dopamine by a turn-on fluorescent biosensor based on aptamer labeled carbon dots and nano-graphite Sensors and Actuators, B: Chemical. 231: 506-512. DOI: 10.1016/j.snb.2016.03.084  0.352
2015 Guo ZN, Xu L, Hu Q, Matei N, Yang P, Tong LS, He Y, Guo Z, Tang J, Yang Y, Zhang JH. Hyperbaric Oxygen Preconditioning Attenuates Hemorrhagic Transformation Through Reactive Oxygen Species/Thioredoxin-Interacting Protein/Nod-Like Receptor Protein 3 Pathway in Hyperglycemic Middle Cerebral Artery Occlusion Rats. Critical Care Medicine. PMID 26646457 DOI: 10.1097/CCM.0000000000001468  0.33
2015 Zheng T, Jiang P, Cao B, Cheng Q, Kong L, Zheng X, Hu Q, You D. DndEi exhibits helicase activity essential for DNA phosphorothioate modification and ATPase activity strongly stimulated by DNA substrate with a GAAC/GTTC motif. The Journal of Biological Chemistry. PMID 26631733 DOI: 10.1074/jbc.M115.694018  0.318
2009 Perry RH, Hu Q, Salazar GA, Cooks RG, Noll RJ. Rephasing ion packets in the Orbitrap mass analyzer to improve resolution and peak shape. Journal of the American Society For Mass Spectrometry. 20: 1397-404. PMID 19299166 DOI: 10.1016/J.Jasms.2009.02.011  0.615
2007 Hu Q, Cooks RG, Noll RJ. Phase-enhanced selective ion ejection in an orbitrap mass spectrometer. Journal of the American Society For Mass Spectrometry. 18: 980-3. PMID 17382556 DOI: 10.1016/J.Jasms.2007.02.004  0.533
2006 Hu Q, Talaty N, Noll RJ, Cooks RG. Desorption electrospray ionization using an Orbitrap mass spectrometer: Exact mass measurements on drugs and peptides. Rapid Communications in Mass Spectrometry : Rcm. 20: 3403-8. PMID 17051609 DOI: 10.1002/Rcm.2757  0.604
2006 Hu Q, Makarov AA, Cooks RG, Noll RJ. Resonant ac dipolar excitation for ion motion control in the Orbitrap mass analyzer. The Journal of Physical Chemistry. A. 110: 2682-9. PMID 16494379 DOI: 10.1021/Jp054485V  0.514
2006 Wu G, Noll RJ, Plass WR, Hu Q, Perry RH, Cooks RG. Ion trajectory simulations of axial ac dipolar excitation in the Orbitrap International Journal of Mass Spectrometry. 254: 53-62. DOI: 10.1016/J.Ijms.2006.05.007  0.616
2005 Hu Q, Noll RJ, Li H, Makarov A, Hardman M, Graham Cooks R. The Orbitrap: a new mass spectrometer. Journal of Mass Spectrometry : Jms. 40: 430-43. PMID 15838939 DOI: 10.1002/Jms.856  0.473
Show low-probability matches.