James G. Pipe - Publications

Affiliations: 
Bioengineering Arizona State University, Tempe, AZ, United States 
Area:
Radiology, Biomedical Engineering, Nuclear Physics

81 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2021 Stokes AM, Ragunathan S, Robison RK, Fuentes A, Bell LC, Karis JP, Pipe JG, Quarles CC. Development of a spiral spin- and gradient-echo (spiral-SAGE) approach for improved multi-parametric dynamic contrast neuroimaging. Magnetic Resonance in Medicine. PMID 34288112 DOI: 10.1002/mrm.28933  1
2021 Peng X, Sui Y, Trzasko JD, Glaser KJ, Huston J, Ehman RL, Pipe JG. Fast 3D MR elastography of the whole brain using spiral staircase: Data acquisition, image reconstruction, and joint deblurring. Magnetic Resonance in Medicine. PMID 34096097 DOI: 10.1002/mrm.28855  0.01
2020 Ooi MB, Li Z, Robison RK, Wang D, Anderson AG, Zwart NR, Bakhru A, Nagaraj S, Mathews T, Hey S, Koonen JJ, Dimitrov IE, Friel HT, Lu Q, Obara M, ... ... Pipe JG, et al. Spiral T1 Spin-Echo for Routine Postcontrast Brain MRI Exams: A Multicenter Multireader Clinical Evaluation. Ajnr. American Journal of Neuroradiology. PMID 32029467 DOI: 10.3174/Ajnr.A6409  1
2020 Anderson AG, Wang D, Pipe JG. Controlled aliasing for improved parallel imaging with a 3D spiral staircase trajectory. Magnetic Resonance in Medicine. PMID 31967342 DOI: 10.1002/mrm.28154  1
2019 Willmering MM, Niedbalski PJ, Wang H, Walkup LL, Robison RK, Pipe JG, Cleveland ZI, Woods JC. Improved pulmonary Xe ventilation imaging via 3D-spiral UTE MRI. Magnetic Resonance in Medicine. PMID 31788858 DOI: 10.1002/Mrm.28114  1
2019 Li Z, Pipe JG, Ooi MB, Kuwabara M, Karis JP. Improving the image quality of 3D FLAIR with a spiral MRI technique. Magnetic Resonance in Medicine. PMID 31393038 DOI: 10.1002/Mrm.27911  1
2019 Willmering MM, Robison RK, Wang H, Pipe JG, Woods JC. Implementation of the FLORET UTE sequence for lung imaging. Magnetic Resonance in Medicine. PMID 31081961 DOI: 10.1002/Mrm.27800  1
2018 Brown SR, Fearnhead NS, Faiz OD, Abercrombie JF, Acheson AG, Arnott RG, Clark SK, Clifford S, Davies RJ, Davies MM, Douie WJP, Dunlop MG, Epstein JC, Evans MD, George BD, ... ... Pipe J, et al. The Association of Coloproctology of Great Britain and Ireland consensus guidelines in surgery for inflammatory bowel disease. Colorectal Disease : the Official Journal of the Association of Coloproctology of Great Britain and Ireland. 20: 3-117. PMID 30508274 DOI: 10.1111/codi.14448  0.01
2018 Robison RK, Li Z, Wang D, Ooi MB, Pipe JG. Correction of B eddy current effects in spiral MRI. Magnetic Resonance in Medicine. PMID 30444004 DOI: 10.1002/Mrm.27583  1
2018 Pipe JG. High-Value MRI. Journal of Magnetic Resonance Imaging : Jmri. PMID 30207620 DOI: 10.1002/jmri.26200  0.01
2018 van Beek EJR, Kuhl C, Anzai Y, Desmond P, Ehman RL, Gong Q, Gold G, Gulani V, Hall-Craggs M, Leiner T, Lim CCT, Pipe JG, Reeder S, Reinhold C, Smits M, et al. Value of MRI in medicine: More than just another test? Journal of Magnetic Resonance Imaging : Jmri. PMID 30145852 DOI: 10.1002/Jmri.26211  0.01
2018 Li Z, Karis JP, Pipe JG. A 2D spiral turbo-spin-echo technique. Magnetic Resonance in Medicine. PMID 29524248 DOI: 10.1002/Mrm.27171  1
2018 Li Y, Mao D, Li Z, Schär M, Pillai JJ, Pipe JG, Lu H. Cardiac-triggered pseudo-continuous arterial-spin-labeling: A cost-effective scheme to further enhance the reliability of arterial-spin-labeling MRI. Magnetic Resonance in Medicine. PMID 29369422 DOI: 10.1002/Mrm.27090  1
2017 Wang D, Zwart NR, Pipe JG. Joint water-fat separation and deblurring for spiral imaging. Magnetic Resonance in Medicine. PMID 28983966 DOI: 10.1002/Mrm.26950  1
2017 Ragunathan S, Pipe JG. Radiofrequency saturation induced bias in aqueductal cerebrospinal fluid flow quantification obtained using two-dimensional cine phase contrast magnetic resonance imaging. Magnetic Resonance in Medicine. PMID 28833454 DOI: 10.1002/Mrm.26883  1
2016 Robison RK, Anderson AG, Pipe JG. Three-dimensional ultrashort echo-time imaging using a FLORET trajectory. Magnetic Resonance in Medicine. PMID 27775843 DOI: 10.1002/Mrm.26500  1
2016 Hu HH, Li Z, Pokorney AL, Chia JM, Stefani N, Pipe JG, Miller JH. Assessment of Cerebral Blood Perfusion Reserve with Acetazolamide Using 3D Spiral ASL MRI: Preliminary Experience in Pediatric Patients. Magnetic Resonance Imaging. PMID 27580517 DOI: 10.1016/J.Mri.2016.08.019  1
2015 Li Z, Hu HH, Miller JH, Karis JP, Cornejo P, Wang D, Pipe JG. A Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo. Ajnr. American Journal of Neuroradiology. PMID 26611994 DOI: 10.3174/Ajnr.A4600  1
2015 Schär M, Eggers H, Zwart NR, Chang Y, Bakhru A, Pipe JG. Dixon water-fat separation in PROPELLER MRI acquired with two interleaved echoes. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. PMID 25772334 DOI: 10.1002/Mrm.25656  1
2015 Wang D, Zwart NR, Li Z, Schär M, Pipe JG. Analytical three-point Dixon method: With applications for spiral water-fat imaging. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. PMID 25762118 DOI: 10.1002/Mrm.25620  1
2015 Li Z, Schär M, Wang D, Zwart NR, Madhuranthakam AJ, Karis JP, Pipe JG. Arterial spin labeled perfusion imaging using three-dimensional turbo spin echo with a distributed spiral-in/out trajectory. Magnetic Resonance in Medicine. PMID 25754947 DOI: 10.1002/Mrm.25645  1
2015 Li Z, Wang D, Robison RK, Zwart NR, Schär M, Karis JP, Pipe JG. Sliding-slab three-dimensional TSE imaging with a spiral-In/Out readout. Magnetic Resonance in Medicine. PMID 25753219 DOI: 10.1002/Mrm.25660  1
2015 Zwart NR, Pipe JG. Graphical programming interface: A development environment for MRI methods. Magnetic Resonance in Medicine. 74: 1449-60. PMID 25385670 DOI: 10.1002/Mrm.25528  1
2014 Chang Y, Pipe JG, Karis JP, Gibbs WN, Zwart NR, Schär M. The effects of SENSE on PROPELLER imaging. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. PMID 25522132 DOI: 10.1002/Mrm.25557  1
2014 Pipe JG, Gibbs WN, Li Z, Karis JP, Schar M, Zwart NR. Revised motion estimation algorithm for PROPELLER MRI. Magnetic Resonance in Medicine. 72: 430-7. PMID 24006354 DOI: 10.1002/Mrm.24929  1
2014 Bhavsar PS, Zwart NR, Pipe JG. Fast, variable system delay correction for spiral MRI. Magnetic Resonance in Medicine. 71: 773-82. PMID 23508831 DOI: 10.1002/Mrm.24730  1
2014 Pipe JG, Zwart NR. Spiral trajectory design: a flexible numerical algorithm and base analytical equations. Magnetic Resonance in Medicine. 71: 278-85. PMID 23440770 DOI: 10.1002/Mrm.24675  1
2013 Turley DC, Pipe JG. Distributed spirals: a new class of three-dimensional k-space trajectories. Magnetic Resonance in Medicine. 70: 413-9. PMID 23042669 DOI: 10.1002/Mrm.24475  1
2013 Lee CY, Li Z, Pipe JG, Debbins JP. Turboprop+: enhanced Turboprop diffusion-weighted imaging with a new phase correction. Magnetic Resonance in Medicine. 70: 497-503. PMID 23023533 DOI: 10.1002/Mrm.24481  1
2013 Zwart NR, Pipe JG. Multidirectional high-moment encoding in phase contrast MRI. Magnetic Resonance in Medicine. 69: 1553-64. PMID 22760964 DOI: 10.1002/Mrm.24390  1
2012 Roher AE, Debbins JP, Malek-Ahmadi M, Chen K, Pipe JG, Maze S, Belden C, Maarouf CL, Thiyyagura P, Mo H, Hunter JM, Kokjohn TA, Walker DG, Kruchowsky JC, Belohlavek M, et al. Cerebral blood flow in Alzheimer's disease. Vascular Health and Risk Management. 8: 599-611. PMID 23109807 DOI: 10.2147/Vhrm.S34874  1
2012 Zwart NR, Johnson KO, Pipe JG. Efficient sample density estimation by combining gridding and an optimized kernel. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 67: 701-10. PMID 21688320 DOI: 10.1002/Mrm.23041  1
2011 Li Z, Pipe JG, Lee CY, Debbins JP, Karis JP, Huo D. X-PROP: a fast and robust diffusion-weighted propeller technique. Magnetic Resonance in Medicine. 66: 341-7. PMID 21661046 DOI: 10.1002/Mrm.23033  1
2011 Pipe JG, Zwart NR, Aboussouan EA, Robison RK, Devaraj A, Johnson KO. A new design and rationale for 3D orthogonally oversampled k-space trajectories. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 66: 1303-11. PMID 21469190 DOI: 10.1002/Mrm.22918  1
2011 Johnson KO, Robison RK, Pipe JG. Rigid body motion compensation for spiral projection imaging. Ieee Transactions On Medical Imaging. 30: 655-65. PMID 21062678 DOI: 10.1109/Tmi.2010.2091146  1
2011 Li Z, Pipe JG, Aboussouan E, Karis JP, Huo D. A parallel imaging technique using mutual calibration for split-blade diffusion-weighted PROPELLER. Magnetic Resonance in Medicine. 65: 638-44. PMID 20928872 DOI: 10.1002/Mrm.22646  1
2010 Robison RK, Devaraj A, Pipe JG. Fast, simple gradient delay estimation for spiral MRI. Magnetic Resonance in Medicine. 63: 1683-90. PMID 20512872 DOI: 10.1002/Mrm.22327  1
2009 Devaraj A, Pipe JG. Elliptical field-of-view PROPELLER imaging. Magnetic Resonance in Medicine. 62: 808-14. PMID 19585595 DOI: 10.1002/Mrm.22006  1
2009 Zwart NR, Pipe JG. Motion corrected intracranial MRA using PROPELLER with RF quadratic encoding. Magnetic Resonance in Medicine. 61: 1405-14. PMID 19353668 DOI: 10.1002/Mrm.21844  1
2009 Johnson KO, Pipe JG. Convolution kernel design and efficient algorithm for sampling density correction. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 61: 439-47. PMID 19165893 DOI: 10.1002/Mrm.21840  1
2009 Huo D, Li Z, Aboussouan E, Karis JP, Pipe JG. Turboprop IDEAL: a motion-resistant fat-water separation technique. Magnetic Resonance in Medicine. 61: 188-95. PMID 19097201 DOI: 10.1002/Mrm.21825  1
2006 Liu J, Redmond MJ, Brodsky EK, Alexander AL, Lu A, Thornton FJ, Schulte MJ, Grist TM, Pipe JG, Block WF. Generation and visualization of four-dimensional MR angiography data using an undersampled 3-D projection trajectory. Ieee Transactions On Medical Imaging. 25: 148-57. PMID 16468449 DOI: 10.1109/Tmi.2005.861706  1
2006 Pipe JG, Zwart N. Turboprop: improved PROPELLER imaging. Magnetic Resonance in Medicine. 55: 380-5. PMID 16402378 DOI: 10.1002/Mrm.20768  1
2005 Arfanakis K, Tamhane AA, Pipe JG, Anastasio MA. k-space undersampling in PROPELLER imaging. Magnetic Resonance in Medicine. 53: 675-83. PMID 15723398 DOI: 10.1002/Mrm.20380  1
2003 Forbes KP, Pipe JG, Karis JP, Farthing V, Heiserman JE. Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences. Ajnr. American Journal of Neuroradiology. 24: 794-8. PMID 12748073  1
2003 Forbes KP, Pipe JG, Heiserman JE. Diffusion-weighted imaging provides support for secondary neuronal damage from intraparenchymal hematoma Neuroradiology. 45: 363-367. PMID 12719952 DOI: 10.1007/S00234-003-0995-Z  1
2003 Forbes KP, Pipe JG, Karis JP, Heiserman JE. Effects of zero-filled interpolation on cervical magnetic resonance angiographic measurement. Ajnr. American Journal of Neuroradiology. 24: 319-22. PMID 12637274  1
2003 Pipe JG. A simple measure of flow disorder and wall shear stress in phase contrast MRI. Magnetic Resonance in Medicine. 49: 543-50. PMID 12594758 DOI: 10.1002/Mrm.10409  1
2003 Pipe JG, Farthing VG. A correlative measure for processing multiangle diffusion-weighted images. Magnetic Resonance in Medicine. 49: 536-42. PMID 12594757 DOI: 10.1002/Mrm.10399  1
2002 Forbes KP, Pipe JG, Karis JP, Heiserman JE. Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging. Radiology. 225: 551-5. PMID 12409594 DOI: 10.1148/Radiol.2252011479  1
2002 Johnson SC, Baxter LC, Wilder LS, Pipe JG, Heiserman JE, Prigatano GP. Neural correlates of self-reflection. Brain : a Journal of Neurology. 125: 1808-14. PMID 12135971 DOI: 10.1093/Brain/Awf181  1
2002 Forbes KP, Pipe JG, Bird CR. Changes in brain water diffusion during the 1st year of life. Radiology. 222: 405-9. PMID 11818606 DOI: 10.1148/Radiol.2222010179  1
2002 Pipe JG, Farthing VG, Forbes KP. Multishot diffusion-weighted FSE using PROPELLER MRI. Magnetic Resonance in Medicine. 47: 42-52. PMID 11754441 DOI: 10.1002/Mrm.10014  1
2001 Forbes KPN, Pipe JG, Bird CR, Heiserman JE. PROPELLER MRI: Clinical testing of a novel technique for quantification and compensation of head motion Journal of Magnetic Resonance Imaging. 14: 215-222. PMID 11536397 DOI: 10.1002/Jmri.1176  1
2001 Pipe JG. Limits of time-of-flight magnetic resonance angiography Topics in Magnetic Resonance Imaging. 12: 163-174. PMID 11432575 DOI: 10.1097/00002142-200106000-00003  1
2001 Forbes KPN, Pipe JG, Heiserman JE. Evidence for cytotoxic edema in the pathogenesis of cerebral venous infarction American Journal of Neuroradiology. 22: 450-455. PMID 11237965  1
2000 Resnick LM, Militianu D, Cunnings AJ, Pipe JG, Evelhoch JL, Soulen RL, Lester MA. Pulse waveform analysis of arterial compliance: relation to other techniques, age, and metabolic variables. American Journal of Hypertension. 13: 1243-9. PMID 11130766 DOI: 10.1016/S0895-7061(00)01219-X  1
2000 Forbes KPN, Pipe JG, Bird R. Neonatal hypoxic-ischemic encephalopathy: Detection with diffusion-weighted MR imaging American Journal of Neuroradiology. 21: 1490-1496. PMID 11003285  1
2000 Ahunbay E, Pipe JG. Rapid method for deblurring spiral MR images Magnetic Resonance in Medicine. 44: 491-494. PMID 10975904 DOI: 10.1002/1522-2594(200009)44:3<491::Aid-Mrm22>3.0.Co;2-Z  1
2000 Pipe JG. Reconstructing MR images from undersampled data: Data-weighing considerations Magnetic Resonance in Medicine. 43: 867-875. PMID 10861882 DOI: 10.1002/1522-2594(200006)43:6<867::Aid-Mrm13>3.0.Co;2-2  1
2000 Johnson SC, Prigatano GP, Zigler LY, Hahn S, Pipe JG, Heiserman JE. Dynamic cerebral change during sustained finger oscillation: Preliminary results with the halstead finger tapping test Neuroimage. 11.  1
1999 Pipe JG. Basic spin physics Magnetic Resonance Imaging Clinics of North America. 7: 607-627. PMID 10631671  1
1999 Pipe JG. Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging Magnetic Resonance in Medicine. 42: 963-969. PMID 10542356 DOI: 10.1002/(Sici)1522-2594(199911)42:5<963::Aid-Mrm17>3.0.Co;2-L  1
1999 Pipe JG. An optimized center-out k-space trajectory for multishot MRI: Comparison with spiral and projection reconstruction Magnetic Resonance in Medicine. 42: 714-720. PMID 10502760 DOI: 10.1002/(Sici)1522-2594(199910)42:4<714::Aid-Mrm13>3.0.Co;2-G  1
1999 Pipe JG, Ahunbay E, Menon P. Effects of interleaf order for spiral MRI of dynamic processes Magnetic Resonance in Medicine. 41: 417-422. PMID 10080293 DOI: 10.1002/(Sici)1522-2594(199902)41:2<417::Aid-Mrm29>3.0.Co;2-W  1
1999 Pipe JG. Flow effects in localized quadratic, partial fourier MRA Magnetic Resonance in Medicine. 41: 309-314. PMID 10080278 DOI: 10.1002/(Sici)1522-2594(199902)41:2<309::Aid-Mrm14>3.0.Co;2-D  1
1999 Pipe JG, Menon P. Sampling density compensation in MRI: Rationale and an iterative numerical solution Magnetic Resonance in Medicine. 41: 179-186. PMID 10025627 DOI: 10.1002/(Sici)1522-2594(199901)41:1<179::Aid-Mrm25>3.0.Co;2-V  1
1998 Pipe JG. Asymmetric sampling along k(slice-select) in two-dimensional ultislice MRI Magnetic Resonance in Medicine. 39: 625-624. PMID 9543425 DOI: 10.1002/Mrm.1910390416  1
1997 Resnick LM, Militianu D, Cunnings AJ, Pipe JG, Evelhoch JL, Soulen RL. Direct magnetic resonance determination of aortic distensibility in essential hypertension: relation to age, abdominal visceral fat, and in situ intracellular free magnesium. Hypertension. 30: 654-9. PMID 9322999 DOI: 10.1161/01.Hyp.30.3.654  1
1996 Pipe JG. Analysis of localized quadratic encoding and reconstruction Magnetic Resonance in Medicine. 36: 137-146. PMID 8795032 DOI: 10.1002/Mrm.1910360122  1
1996 Zhao M, Pipe JG, Bonnett J, Evelhoch JL. Early detection of treatment response by diffusion-weighted 1H-NMR spectroscopy in a murine tumour in vivo British Journal of Cancer. 73: 61-64. PMID 8554985 DOI: 10.1038/Bjc.1996.11  1
1995 Fowlkes JB, Emelianov SY, Pipe JG, Skovoroda AR, Carson PL, Adler RS, Sarvazyan AP. Magnetic-resonance imaging techniques for detection of elasticity variation. Medical Physics. 22: 1771-8. PMID 8587532 DOI: 10.1118/1.597633  1
1995 Pipe JG. Spatial encoding and reconstruction in MRI with quadratic phase profiles Magnetic Resonance in Medicine. 33: 24-33. PMID 7891532 DOI: 10.1002/Mrm.1910330105  1
1995 Brunberg JA, Chenevert TL, McKeever PE, Ross DA, Junck LR, Muraszko KM, Dauser R, Pipe JG, Betley AT. In vivo MR determination of water diffusion coefficients and diffusion anisotropy: correlation with structural alteration in gliomas of the cerebral hemispheres. Ajnr. American Journal of Neuroradiology. 16: 361-71. PMID 7726086  1
1995 Pipe JG, Duerk JL. Analytical resolution and noise characteristics of linearly reconstructed magnetic resonance data with arbitrary k-space sampling Magnetic Resonance in Medicine. 34: 170-178. PMID 7476075 DOI: 10.1002/Mrm.1910340207  1
1992 Pipe JG. A fast method for obtaining a "continuous" sample of the inversion-recovery curve using spatially swept adiabatic inversion Journal of Magnetic Resonance (1969). 99: 582-589. DOI: 10.1016/0022-2364(92)90213-Q  1
1991 Chenevert TL, Pipe JG, Williams DM, Brunberg JA. Quantitative measurement of tissue perfusion and diffusion in vivo Magnetic Resonance in Medicine. 17: 197-212. PMID 2067394 DOI: 10.1002/Mrm.1910170123  1
1991 Pipe JG, Chenevert TL. A progressive gradient moment nulling design technique Magnetic Resonance in Medicine. 19: 175-179. PMID 2046531 DOI: 10.1002/Mrm.1910190116  1
1991 Pipe JG, Boes JL, Chenevert TL. Method for measuring three-dimensional motion with tagged MR imaging Radiology. 181: 591-595. PMID 1924810 DOI: 10.1148/Radiology.181.2.1924810  1
1991 Chenevert TL, Pipe JG. Effect of bulk tissue motion on quantitative perfusion and diffusion magnetic resonance imaging Magnetic Resonance in Medicine. 19: 261-265. PMID 1881313 DOI: 10.1002/Mrm.1910190212  1
1990 Chenevert TL, Brunberg JA, Pipe JG. Anisotropic diffusion in human white matter: Demonstration with MR techniques in vivo Radiology. 177: 401-405. PMID 2217776  1
Show low-probability matches.