Patrick W. Goodwill, D.Eng. - Publications

Affiliations: 
2010 Bioengineering University of California, Berkeley, Berkeley, CA, United States 
Area:
Biomedical Engineering, Electronics and Electrical Engineering

68/74 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2023 Carlton H, Weber M, Peters M, Arepally N, Lad YS, Jaswal A, Ivkov R, Attaluri A, Goodwill P. HYPER: pre-clinical device for spatially-confined magnetic particle hyperthermia. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 40: 2272067. PMID 37875265 DOI: 10.1080/02656736.2023.2272067  0.315
2022 Vurro F, Gerosa M, Busato A, Muccilli M, Milan E, Gaudet J, Goodwill P, Mansfield J, Forlin E, Negri A, Gherlinzoni F, Morana G, Gottardi M, Matteazzi P, Wintermark M, et al. Doped Ferrite Nanoparticles Exhibiting Self-Regulating Temperature as Magnetic Fluid Hyperthermia Antitumoral Agents, with Diagnostic Capability in Magnetic Resonance Imaging and Magnetic Particle Imaging. Cancers. 14. PMID 36291935 DOI: 10.3390/cancers14205150  0.332
2022 Healy S, Bakuzis AF, Goodwill PW, Attaluri A, Bulte JWM, Ivkov R. Clinical magnetic hyperthermia requires integrated magnetic particle imaging. Wiley Interdisciplinary Reviews. Nanomedicine and Nanobiotechnology. e1779. PMID 35238181 DOI: 10.1002/wnan.1779  0.445
2020 Chandrasekharan P, Tay ZW, Hensley D, Zhou XY, Fung BK, Colson C, Lu Y, Fellows BD, Huynh Q, Saayujya C, Yu E, Orendorff R, Zheng B, Goodwill P, Rinaldi C, et al. Using magnetic particle imaging systems to localize and guide magnetic hyperthermia treatment: tracers, hardware, and future medical applications. Theranostics. 10: 2965-2981. PMID 32194849 DOI: 10.7150/Thno.40858  0.707
2020 Ren G, Gaudet JM, Gerosa M, Zhang Y, Mansfield J, Wintermark M, Goodwill P. Abstract 2770: Imaging cancer immunology: Monitoring CD47 mAb treatment in vivo by magnetic particle imaging Tumor Biology. DOI: 10.1158/1538-7445.Am2020-2770  0.551
2019 Tay ZW, Hensley D, Ma J, Chandrasekharan P, Zheng B, Goodwill P, Conolly S. Pulsed Excitation in Magnetic Particle Imaging. Ieee Transactions On Medical Imaging. PMID 30762537 DOI: 10.1109/Tmi.2019.2898202  0.75
2018 Chandrasekharan P, Tay ZW, Zhou XY, Yu E, Orendorff R, Hensley D, Huynh Q, Fung KLB, VanHook CC, Goodwill P, Zheng B, Conolly S. A perspective on a rapid and radiation-free tracer imaging modality, Magnetic Particle Imaging, with promise for clinical translation. The British Journal of Radiology. 20180326. PMID 29888968 DOI: 10.1259/Bjr.20180326  0.759
2018 Zhou XY, Tay ZW, Chandrasekharan P, Yu EY, Hensley DW, Orendorff R, Jeffris KE, Mai D, Zheng B, Goodwill PW, Conolly SM. Magnetic particle imaging for radiation-free, sensitive and high-contrast vascular imaging and cell tracking. Current Opinion in Chemical Biology. 45: 131-138. PMID 29754007 DOI: 10.1016/J.Cbpa.2018.04.014  0.787
2018 Wang P, Goodwill PW, Pandit P, Gaudet J, Ross A, Wang J, Yu E, Hensley DW, Doyle TC, Contag CH, Conolly S, Moore A. Magnetic particle imaging of islet transplantation in the liver and under the kidney capsule in mouse models. Quantitative Imaging in Medicine and Surgery. 8: 114-122. PMID 29675353 DOI: 10.21037/Qims.2018.02.06  0.66
2018 Tay ZW, Chandrasekharan P, Chiu-Lam A, Hensley DW, Dhavalikar R, Zhou XY, Yu EY, Goodwill PW, Zheng B, Rinaldi C, Conolly SM. Magnetic Particle Imaging Guided Heating In Vivo using Gradient Fields For Arbitrary Localization of Magnetic Hyperthermia Therapy. Acs Nano. PMID 29570277 DOI: 10.1021/Acsnano.8B00893  0.758
2018 Wang P, Goodwill PW, Pandit P, Gaudet J, Ross A, Wang J, Yu E, Hensley DW, Doyle TC, Contag CH, Conolly S, Moore A. Maximum intensity projection of an intrahepatic transplant 1 day after Tx Asvide. 5: 306-306. DOI: 10.21037/asvide.2018.306  0.508
2018 Wang P, Goodwill PW, Pandit P, Gaudet J, Ross A, Wang J, Yu E, Hensley DW, Doyle TC, Contag CH, Conolly S, Moore A. Maximum intensity projection of an under the kidney capsule transplant 1 day after Tx Asvide. 5: 304-304. DOI: 10.21037/asvide.2018.304  0.509
2017 Lu K, Goodwill P, Zheng B, Conolly S. Multi-channel Acquisition for Isotropic Resolution in Magnetic Particle Imaging. Ieee Transactions On Medical Imaging. PMID 29990139 DOI: 10.1109/Tmi.2017.2787500  0.777
2017 Yu EY, Chandrasekharan P, Berzon R, Tay ZW, Zhou XY, Khandhar AP, Ferguson RM, Kemp SJ, Zheng B, Goodwill PW, Wendland MF, Krishnan KM, Behr S, Carter J, Conolly SM. Magnetic Particle Imaging for Highly Sensitive, Quantitative and Safe in vivo Gut Bleed Detection in a Murine Model. Acs Nano. PMID 29165995 DOI: 10.1021/Acsnano.7B04844  0.749
2017 Zheng B, Goodwill PW, Dixit N, Xiao D, Zhang W, Gunel B, Lu K, Scott GC, Conolly SM. Optimal Broadband Noise Matching to Inductive Sensors: Application to Magnetic Particle Imaging. Ieee Transactions On Biomedical Circuits and Systems. PMID 28742047 DOI: 10.1109/Tbcas.2017.2712566  0.662
2017 Zheng B, Yu E, Orendorff R, Lu K, Konkle JJ, Tay ZW, Hensley D, Zhou XY, Chandrasekharan P, Saritas EU, Goodwill PW, Hazle JD, Conolly SM. Seeing SPIOs Directly In Vivo with Magnetic Particle Imaging. Molecular Imaging and Biology : Mib : the Official Publication of the Academy of Molecular Imaging. PMID 28396973 DOI: 10.1007/S11307-017-1081-Y  0.759
2017 Orendorff R, Peck AJ, Zheng B, Shirazi SN, Matthew Ferguson R, Khandhar AP, Kemp SJ, Goodwill P, Krishnan KM, Brooks GA, Kaufer D, Conolly S. First in vivo traumatic brain injury imaging via magnetic particle imaging. Physics in Medicine and Biology. 62: 3501-3509. PMID 28378708 DOI: 10.1088/1361-6560/Aa52Ad  0.713
2017 Zhou XY, Jeffris K, Yu E, Zheng B, Goodwill P, Nahid P, Conolly S. First in vivo magnetic particle imaging of lung perfusion in rats. Physics in Medicine and Biology. PMID 28218614 DOI: 10.1088/1361-6560/Aa616C  0.744
2017 Yu EY, Bishop M, Zheng B, Ferguson RM, Khandhar AP, Kemp SJ, Krishnan KM, Goodwill PW, Conolly SM. Magnetic Particle Imaging: A Novel in vivo Imaging Platform for Cancer Detection. Nano Letters. PMID 28206771 DOI: 10.1021/Acs.Nanolett.6B04865  0.743
2017 Keselman P, Yu E, Zhou X, Goodwill P, Chandrasekharan P, Ferguson RM, Khandhar A, Kemp S, Krishnan K, Zheng B, Conolly S. Tracking short-term biodistribution and long-term clearance of SPIO tracers in magnetic particle imaging. Physics in Medicine and Biology. PMID 28177301 DOI: 10.1088/1361-6560/Aa5F48  0.718
2017 Khandhar AP, Keselman P, Kemp SJ, Ferguson RM, Goodwill PW, Conolly SM, Krishnan KM. Evaluation of PEG-coated iron oxide nanoparticles as blood pool tracers for preclinical magnetic particle imaging. Nanoscale. PMID 28059427 DOI: 10.1039/C6Nr08468K  0.739
2017 Hensley D, Tay ZW, Dhavalikar R, Goodwill P, Zheng B, Rinaldi C, Conolly S. A theranostic platform for localized magnetic fluid hyperthermia and magnetic particle imaging Proceedings of Spie. 10066: 1006603. DOI: 10.1117/12.2256350  0.619
2016 Hensley DW, Tay ZW, Dhavalikar R, Zheng B, Goodwill P, Rinaldi C, Conolly S. Combining magnetic particle imaging and magnetic fluid hyperthermia in a theranostic platform. Physics in Medicine and Biology. PMID 28032621 DOI: 10.1088/1361-6560/Aa5601  0.744
2016 Tay ZW, Goodwill PW, Hensley DW, Taylor LA, Zheng B, Conolly SM. A High-Throughput, Arbitrary-Waveform, MPI Spectrometer and Relaxometer for Comprehensive Magnetic Particle Optimization and Characterization. Scientific Reports. 6: 34180. PMID 27686629 DOI: 10.1038/Srep34180  0.717
2016 Bauer LM, Hensley DW, Zheng B, Tay ZW, Goodwill PW, Griswold MA, Conolly SM. Eddy current-shielded x-space relaxometer for sensitive magnetic nanoparticle characterization. The Review of Scientific Instruments. 87: 055109. PMID 27250472 DOI: 10.1063/1.4950779  0.732
2016 Zheng B, von See MP, Yu E, Gunel B, Lu K, Vazin T, Schaffer DV, Goodwill PW, Conolly SM. Quantitative Magnetic Particle Imaging Monitors the Transplantation, Biodistribution, and Clearance of Stem Cells In Vivo. Theranostics. 6: 291-301. PMID 26909106 DOI: 10.7150/Thno.13728  0.71
2016 Croft LR, Goodwill PW, Konkle JJ, Arami H, Price DA, Li AX, Saritas EU, Conolly SM. Low drive field amplitude for improved image resolution in magnetic particle imaging. Medical Physics. 43: 424. PMID 26745935 DOI: 10.1118/1.4938097  0.761
2016 Goodwill P, Zheng B, Spitler R. Breaking New Ground in Molecular Imaging Genetic Engineering & Biotechnology News. 36: 18-19. DOI: 10.1089/gen.36.16.09  0.345
2016 Dhavalikar R, Hensley D, Maldonado-Camargo L, Croft LR, Ceron S, Goodwill PW, Conolly SM, Rinaldi C. Finite magnetic relaxation in x-space magnetic particle imaging: Comparison of measurements and ferrohydrodynamic models Journal of Physics D: Applied Physics. 49. DOI: 10.1088/0022-3727/49/30/305002  0.747
2015 Konkle JJ, Goodwill PW, Hensley DW, Orendorff RD, Lustig M, Conolly SM. A Convex Formulation for Magnetic Particle Imaging X-Space Reconstruction. Plos One. 10: e0140137. PMID 26495839 DOI: 10.1371/Journal.Pone.0140137  0.75
2015 Zheng B, Vazin T, Goodwill PW, Conway A, Verma A, Ulku Saritas E, Schaffer D, Conolly SM. Magnetic Particle Imaging tracks the long-term fate of in vivo neural cell implants with high image contrast. Scientific Reports. 5: 14055. PMID 26358296 DOI: 10.1038/Srep14055  0.745
2015 Saritas EU, Goodwill PW, Conolly SM. Effects of pulse duration on magnetostimulation thresholds. Medical Physics. 42: 3005-12. PMID 26127053 DOI: 10.1118/1.4921209  0.713
2015 Arami H, Khandhar AP, Tomitaka A, Yu E, Goodwill PW, Conolly SM, Krishnan KM. In vivo multimodal magnetic particle imaging (MPI) with tailored magneto/optical contrast agents. Biomaterials. 52: 251-61. PMID 25818431 DOI: 10.1016/J.Biomaterials.2015.02.040  0.738
2015 Ferguson RM, Khandhar AP, Kemp SJ, Arami H, Saritas EU, Croft LR, Konkle J, Goodwill PW, Halkola A, Rahmer J, Borgert J, Conolly SM, Krishnan KM. Magnetic particle imaging with tailored iron oxide nanoparticle tracers. Ieee Transactions On Medical Imaging. 34: 1077-84. PMID 25438306 DOI: 10.1109/Tmi.2014.2375065  0.78
2015 Goodwill P, Ferguson M, Yu E, Zheng B, Lu K, Khandhar A, Kemp S, Krishnan K, Conolly S. E-139 in vivoperfusion imaging using magnetic particle imaging Journal of Neurointerventional Surgery. 7: A105.1-A105. DOI: 10.1136/Neurintsurg-2015-011917.213  0.526
2014 Shapiro MG, Goodwill PW, Neogy A, Yin M, Foster FS, Schaffer DV, Conolly SM. Biogenic gas nanostructures as ultrasonic molecular reporters. Nature Nanotechnology. 9: 311-6. PMID 24633522 DOI: 10.1038/Nnano.2014.32  0.618
2013 Konkle JJ, Goodwill PW, Saritas EU, Zheng B, Lu K, Conolly SM. Twenty-fold acceleration of 3D projection reconstruction MPI. Biomedizinische Technik. Biomedical Engineering. 58: 565-76. PMID 23940058 DOI: 10.1515/Bmt-2012-0062  0.722
2013 Saritas EU, Goodwill PW, Zhang GZ, Conolly SM. Magnetostimulation limits in magnetic particle imaging. Ieee Transactions On Medical Imaging. 32: 1600-10. PMID 23649181 DOI: 10.1109/Tmi.2013.2260764  0.691
2013 Lu K, Goodwill PW, Saritas EU, Zheng B, Conolly SM. Linearity and shift invariance for quantitative magnetic particle imaging. Ieee Transactions On Medical Imaging. 32: 1565-75. PMID 23568496 DOI: 10.1109/Tmi.2013.2257177  0.754
2013 Saritas EU, Goodwill PW, Croft LR, Konkle JJ, Lu K, Zheng B, Conolly SM. Magnetic particle imaging (MPI) for NMR and MRI researchers. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 229: 116-26. PMID 23305842 DOI: 10.1016/J.Jmr.2012.11.029  0.753
2013 Konkle JJ, Goodwill PW, Carrasco-Zevallos OM, Conolly SM. Projection reconstruction magnetic particle imaging. Ieee Transactions On Medical Imaging. 32: 338-47. PMID 23193308 DOI: 10.1109/Tmi.2012.2227121  0.704
2013 Lu K, Zheng B, Konkle J, Saritas E, Goodwill P, Conolly S. Towards multidimensional x-space magnetic particle imaging for improved resolution 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528389  0.66
2013 Drews LB, Croft LR, Kosuge H, Saritas EU, Goodwill PW, McConnell MV, Conolly SM, Tirrell MV. Imaging atherosclerotic plaques in vivo using peptide-functionalized iron oxide nanoparticles 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528388  0.616
2013 Goodwill PW, Croft LR, Konkle JJ, Lu K, Saritas EU, Zheng B, Conolly SM. A 7 T/M 3D X-space MPI mouse and rat scanner 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528387  0.689
2013 Price DA, Croft LR, Saritas EU, Goodwill PW, Conolly SM. Large tip solution to dynamic Langevin equation for MPI 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528385  0.485
2013 Price DA, Sun G. GL, Goodwill PW, Saritas EU, Conolly SM. Improving conspicuity in MPI by equalization of the 'broad tails' of the MPI point spread function 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528384  0.505
2013 Yang W, Zheng B, Vazin T, Goodwill PW, Saritas EU, Schaffer DV, Conolly SM. In vivo magnetic nanoparticle cytometer for stem cells in small animals 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528383  0.609
2013 Croft LR, Goodwill PW, Price DA, Saritas EU, Li AX, Conolly SM. Effects of scanning rate on relaxation-induced blurring in magnetic particle image 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528382  0.725
2013 Zheng B, Yang W, Massey T, Goodwill PW, Conolly SM. High-power active interference suppression in magnetic particle imaging 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528381  0.604
2013 Saritas EU, Goodwill PW, Chang D, Conolly SM. Effects of frequency and pulse duration on magnetostimulation limits for MPI 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528334  0.509
2013 Zheng B, Vazin T, Yang W, Goodwill PW, Saritas EU, Croft LR, Schaffer DV, Conolly SM. Quantitative stem cell imaging with magnetic particle imaging 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528323  0.741
2013 Konkle JJ, Goodwill PW, Saritas EU, Conolly SM. Twenty-fold acquisition time improvement in 3D projection reconstruction MPI 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528322  0.7
2012 Goodwill PW, Saritas EU, Croft LR, Kim TN, Krishnan KM, Schaffer DV, Conolly SM. X-space MPI: magnetic nanoparticles for safe medical imaging. Advanced Materials (Deerfield Beach, Fla.). 24: 3870-7. PMID 22988557 DOI: 10.1002/Adma.201200221  0.729
2012 Croft LR, Goodwill PW, Conolly SM. Relaxation in x-space magnetic particle imaging. Ieee Transactions On Medical Imaging. 31: 2335-42. PMID 22968211 DOI: 10.1109/Tmi.2012.2217979  0.745
2012 Kim TN, Goodwill PW, Chen Y, Conolly SM, Schaffer CB, Liepmann D, Wang RA. Line-scanning particle image velocimetry: an optical approach for quantifying a wide range of blood flow speeds in live animals. Plos One. 7: e38590. PMID 22761686 DOI: 10.1371/Journal.Pone.0038590  0.627
2012 Goodwill PW, Konkle JJ, Zheng B, Saritas EU, Conolly SM. Projection x-space magnetic particle imaging. Ieee Transactions On Medical Imaging. 31: 1076-85. PMID 22552332 DOI: 10.1109/Tmi.2012.2185247  0.73
2012 Goodwill PW, Lu K, Zheng B, Conolly SM. An x-space magnetic particle imaging scanner. The Review of Scientific Instruments. 83: 033708. PMID 22462930 DOI: 10.1063/1.3694534  0.779
2011 Goodwill PW, Conolly SM. Multidimensional x-space magnetic particle imaging. Ieee Transactions On Medical Imaging. 30: 1581-90. PMID 21402508 DOI: 10.1109/Tmi.2011.2125982  0.773
2011 Goodwill PW, Conolly SM. Experimental demonstration of x-space magnetic particle imaging Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7965. DOI: 10.1117/12.878659  0.754
2011 Tamrazian A, Goodwill P, Croft LR, Pidaparthi R, Ferguson RM, Krishnan K, Conolly S. X-space MPI relaxometry: Methods and initial data Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7965. DOI: 10.1117/12.878608  0.75
2011 Lu K, Goodwill P, Zheng B, Conolly S. The impact of filtering direct-feedthrough on the x-space theory of magnetic particle imaging Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7965. DOI: 10.1117/12.878446  0.732
2011 Zheng B, Goodwill P, Conolly S. Transmit filter design methods for magnetic particle imaging Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7965. DOI: 10.1117/12.878443  0.688
2011 Konkle J, Goodwill P, Conolly S. Development of a field free line magnet for projection MPI Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7965. DOI: 10.1117/12.878435  0.747
2011 Croft LR, Goodwill P, Tamrazian A, Krishnan K, Conolly S. The x-space formulation of magnetic particle imaging including nonnegligible relaxation effects Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7965. DOI: 10.1117/12.878418  0.775
2011 Goodwill PW, Tamrazian A, Croft LR, Lu CD, Johnson EM, Pidaparthi R, Ferguson RM, Khandhar AP, Krishnan KM, Conolly SM. Ferrohydrodynamic relaxometry for magnetic particle imaging Applied Physics Letters. 98. DOI: 10.1063/1.3604009  0.758
2010 Lee GC, Goodwill PW, Phuong K, Inglis BA, Scott GC, Hargreaves BA, Li L, Chen AC, Shah RN, Conolly SM. Pyrolytic graphite foam: a passive magnetic susceptibility matching material. Journal of Magnetic Resonance Imaging : Jmri. 32: 684-91. PMID 20815067 DOI: 10.1002/Jmri.22270  0.693
2010 Goodwill PW, Conolly SM. The X-space formulation of the magnetic particle imaging process: 1-D signal, resolution, bandwidth, SNR, SAR, and magnetostimulation. Ieee Transactions On Medical Imaging. 29: 1851-9. PMID 20529726 DOI: 10.1109/Tmi.2010.2052284  0.782
2009 Goodwill PW, Scott GC, Stang PP, Conolly SM. Narrowband magnetic particle imaging. Ieee Transactions On Medical Imaging. 28: 1231-7. PMID 19211340 DOI: 10.1109/Tmi.2009.2013849  0.79
Low-probability matches (unlikely to be authored by this person)
2021 Rubia-Rodríguez I, Santana-Otero A, Spassov S, Tombácz E, Johansson C, De La Presa P, Teran FJ, Del Puerto Morales M, Veintemillas-Verdaguer S, Thanh NTK, Besenhard MO, Wilhelm C, Gazeau F, Harmer Q, Mayes E, ... ... Goodwill P, et al. Whither Magnetic Hyperthermia? A Tentative Roadmap. Materials (Basel, Switzerland). 14. PMID 33546176 DOI: 10.3390/ma14040706  0.254
2001 Gao J, Arunagiri T, Chen J, Goodwill P, Chyan O, Perez J, Golden D. ChemInform Abstract: Preparation and Characterization of Metal Nanoparticles on a Diamond Surface. Cheminform. 32: no-no. DOI: 10.1002/chin.200109240  0.089
2000 Gao J, Arunagiri T, Chen J, Goodwill P, Chyan O, Perez J, Golden D. Preparation and Characterization of Metal Nanoparticles on a Diamond Surface Chemistry of Materials. 12: 3495-3500. DOI: 10.1021/Cm000465O  0.082
2000 Price LE, Goodwill P, Young PC, Rowan JS. A data-based mechanistic modelling (DBM) approach to understanding dynamic sediment transmission through Wyresdale Park Reservoir, Lancashire, UK Hydrological Processes. 14: 63-78. DOI: 10.1002/(SICI)1099-1085(200001)14:1<63::AID-HYP910>3.0.CO;2-H  0.036
1995 Rowan J, Goodwill P, Greco M. Temporal variability in catchment sediment yield determined from repeated bathymetric surveys: Abbeystead Reservoir, U.K. Physics and Chemistry of the Earth. 20: 199-206. DOI: 10.1016/0079-1946(95)00024-0  0.013
1995 Goodwill P, Rowan J, Greco M. Sediment routing through reservoirs, Wyresdale Park Reservoir, Lancashire, U.K. Physics and Chemistry of the Earth. 20: 183-190. DOI: 10.1016/0079-1946(95)00022-4  0.01
Hide low-probability matches.