Kai-Nan An - Publications

Affiliations: 
Biomedical Engineering College of Medicine - Mayo Clinic 
Area:
Biomechanics Biophysics, Biomedical Engineering, Aging

103 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2019 Thoreson AR, Rappaport PO, Yang TH, Reisdorf RL, Zhao C, An KN, Amadio PC. Calculation of flexor pollicis longus moment arm for wrist motion in a cadaver model validates the tenodesis effect for therapy. Journal of Hand Therapy : Official Journal of the American Society of Hand Therapists. PMID 30792111 DOI: 10.1016/j.jht.2019.01.005  0.4
2019 Itoigawa Y, Hooke AW, Sperling JW, Steinmann SP, Zhao KD, Itoi E, An KN. The effect of subscapularis muscle contraction on coaptation of anteroinferior glenohumeral ligament-labrum complex after Bankart repair. Journal of Biomechanics. PMID 30691988 DOI: 10.1016/j.jbiomech.2019.01.023  0.44
2018 Liu Q, Yu Y, Reisdorf RL, Qi J, Lu CK, Berglund LJ, Amadio PC, Moran SL, Steinmann SP, An KN, Gingery A, Zhao C. Engineered tendon-fibrocartilage-bone composite and bone marrow-derived mesenchymal stem cell sheet augmentation promotes rotator cuff healing in a non-weight-bearing canine model. Biomaterials. 192: 189-198. PMID 30453215 DOI: 10.1016/j.biomaterials.2018.10.037  0.4
2018 Giambini H, Hatta T, Rezaei A, An KN. Extensibility of the supraspinatus muscle can be predicted by combining shear wave elastography and magnetic resonance imaging-measured quantitative metrics of stiffness and volumetric fat infiltration: A cadaveric study. Clinical Biomechanics (Bristol, Avon). 57: 144-149. PMID 29986277 DOI: 10.1016/j.clinbiomech.2018.07.001  0.88
2018 Cheng YS, Zhou B, Kubo K, An KN, Moran SL, Amadio PC, Zhang X, Zhao C. Comparison of two ways of altering carpal tunnel pressure with ultrasound surface wave elastography. Journal of Biomechanics. PMID 29731324 DOI: 10.1016/j.jbiomech.2018.04.003  0.4
2018 Wei Z, Reisdorf RL, Thoreson AR, Jay GD, Moran SL, An KN, Amadio PC, Zhao C. Comparison of Autograft and Allograft with Surface Modification for Flexor Tendon Reconstruction: A Canine in Vivo Model. The Journal of Bone and Joint Surgery. American Volume. 100: e42. PMID 29613931 DOI: 10.2106/JBJS.17.00925  0.4
2018 Wanderman NR, Mallet C, Giambini H, Bao N, Zhao C, An KN, Freedman BA, Nassr A. An Ovariectomy-Induced Rabbit Osteoporotic Model: A New Perspective. Asian Spine Journal. 12: 12-17. PMID 29503677 DOI: 10.4184/asj.2018.12.1.12  0.88
2018 Berton A, Salvatore G, Giambini H, Ciuffreda M, Longo UG, Denaro V, Thoreson A, An KN. A 3D finite element model of prophylactic vertebroplasty in the metastatic spine: Vertebral stability and stress distribution on adjacent vertebrae. The Journal of Spinal Cord Medicine. 1-7. PMID 29446706 DOI: 10.1080/10790268.2018.1432309  0.88
2018 Salvatore G, Berton A, Giambini H, Ciuffreda M, Florio P, Longo UG, Denaro V, Thoreson A, An KN. Biomechanical effects of metastasis in the osteoporotic lumbar spine: A Finite Element Analysis. Bmc Musculoskeletal Disorders. 19: 38. PMID 29402261 DOI: 10.1186/s12891-018-1953-6  0.88
2017 Cheng YS, Reisdorf R, Vrieze A, Moran SL, Amadio PC, An KN, Zhao C. Kinetic analysis of canine gait on the effect of failure tendon repair and tendon graft. Journal of Biomechanics. PMID 29169630 DOI: 10.1016/j.jbiomech.2017.10.041  0.4
2017 Kubo K, Cheng YS, Zhou B, An KN, Moran SL, Amadio PC, Zhang X, Zhao C. The quantitative evaluation of the relationship between the forces applied to the palm and carpal tunnel pressure. Journal of Biomechanics. PMID 29137727 DOI: 10.1016/j.jbiomech.2017.10.039  0.4
2017 Wang L, Thoreson AR, Trousdale RT, Morrey BF, Dai K, An KN. Radiographic cup anteversion measurement corrected from pelvic tilt. Medical Engineering & Physics. PMID 28888787 DOI: 10.1016/j.medengphy.2017.08.008  0.32
2017 Hatta T, Giambini H, Itoigawa Y, Hooke AW, Sperling JW, Steinmann SP, Itoi E, An KN. Quantifying extensibility of rotator cuff muscle with tendon rupture using shear wave elastography: A cadaveric study. Journal of Biomechanics. PMID 28778388 DOI: 10.1016/j.jbiomech.2017.07.009  0.88
2017 Kubo K, Zhou B, Cheng YS, Yang TH, Qiang B, An KN, Moran SL, Amadio PC, Zhang X, Zhao C. Ultrasound Elastography for Carpal Tunnel Pressure Measurement: A Cadaveric Validation Study. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. PMID 28731271 DOI: 10.1002/jor.23658  0.4
2017 Matsuura Y, Rokkaku T, Suzuki T, Thoreson AR, An KN, Kuniyoshi K. Evaluation of Bone Atrophy After Treatment of Forearm Fracture Using Nonlinear Finite Element Analysis: A Comparative Study of Locking Plates and Conventional Plates. The Journal of Hand Surgery. PMID 28552442 DOI: 10.1016/j.jhsa.2017.03.041  0.32
2017 Giambini H, Hatta T, Krzysztof GR, Widholm P, Karlsson A, Leinhard OD, Adkins MC, Zhao C, An KN. Intramuscular Fat Infiltration Evaluated by Magnetic Resonance Imaging Predicts the Extensibility of the Supraspinatus Muscle. Muscle & Nerve. PMID 28439938 DOI: 10.1002/mus.25673  0.88
2017 Cloud BA, Zhao KD, Ellingson AM, Nassr A, Windebank AJ, An KN. Increased Seat Dump Angle in a Manual Wheelchair is Associated with Changes in Thoracolumbar Lordosis and Scapular Kinematics during Propulsion. Archives of Physical Medicine and Rehabilitation. PMID 28322758 DOI: 10.1016/j.apmr.2017.02.014  0.88
2016 Filius A, Thoreson AR, Ozasa Y, An KN, Zhao C, Amadio PC. Delineation of the mechanisms of tendon gliding resistance within the carpal tunnel. Clinical Biomechanics (Bristol, Avon). 41: 48-53. PMID 27939953 DOI: 10.1016/j.clinbiomech.2016.12.001  0.4
2016 Sahu D, Fitzsimmons JS, Thoreson AR, An KN, O'Driscoll SW. Radiocapitellar contact characteristics during prosthetic radial head subluxation. Journal of Shoulder and Elbow Surgery. PMID 27727059 DOI: 10.1016/j.jse.2016.07.005  0.32
2016 Breighner R, Holmes DR, Leng S, An KN, McCollough C, Zhao K. Relative accuracy of spin-image-based registration of partial capitate bones in 4DCT of the wrist. Computer Methods in Biomechanics and Biomedical Engineering. Imaging & Visualization. 4: 360-367. PMID 27722036 DOI: 10.1080/21681163.2014.947384  0.44
2016 Itoigawa Y, Hooke AW, Sperling JW, Steinmann SP, Zhao KD, Yamamoto N, Itoi E, An KN. Repairing the Capsule to the Transferred Coracoid Preserves External Rotation in the Modified Latarjet Procedure. The Journal of Bone and Joint Surgery. American Volume. 98: 1484-9. PMID 27605693 DOI: 10.2106/JBJS.15.01069  0.44
2016 Mo J, Xu H, Qiang B, Giambini H, Kinnick R, An KN, Chen S, Luo Z. Bias of shear wave elasticity measurements in thin layer samples and a simple correction strategy. Springerplus. 5: 1341. PMID 27588234 DOI: 10.1186/s40064-016-2937-3  0.88
2016 Hatta T, Giambini H, Zhao C, Sperling JW, Steinmann SP, Itoi E, An KN. Biomechanical Effect of Margin Convergence Techniques: Quantitative Assessment of Supraspinatus Muscle Stiffness. Plos One. 11: e0162110. PMID 27583402 DOI: 10.1371/journal.pone.0162110  0.88
2016 Yang TH, Lu SC, Lin WJ, Zhao K, Zhao C, An KN, Jou IM, Lee PY, Kuo LC, Su FC. Assessing Finger Joint Biomechanics by Applying Equal Force to Flexor Tendons In Vitro Using a Novel Simultaneous Approach. Plos One. 11: e0160301. PMID 27513744 DOI: 10.1371/journal.pone.0160301  0.4
2016 Hatta T, Giambini H, Hooke AW, Zhao C, Sperling JW, Steinmann SP, Yamamoto N, Itoi E, An KN. Comparison of Passive Stiffness Changes in the Supraspinatus Muscle After Double-Row and Knotless Transosseous-Equivalent Rotator Cuff Repair Techniques: A Cadaveric Study. Arthroscopy : the Journal of Arthroscopic & Related Surgery : Official Publication of the Arthroscopy Association of North America and the International Arthroscopy Association. PMID 27157656 DOI: 10.1016/j.arthro.2016.02.024  0.88
2016 Hatta T, Giambini H, Sukegawa K, Yamanaka Y, Sperling JW, Steinmann SP, Itoi E, An KN. Quantified Mechanical Properties of the Deltoid Muscle Using the Shear Wave Elastography: Potential Implications for Reverse Shoulder Arthroplasty. Plos One. 11: e0155102. PMID 27152934 DOI: 10.1371/journal.pone.0155102  0.88
2016 Zhao KD, Ben-Abraham EI, Magnuson DJ, Camp JJ, Berglund LJ, An KN, Bronfort G, Gay RE. Effect of Off-Axis Fluoroscopy Imaging on 2-Dimensional Kinematics in the Lumbar Spine: A Dynamic In Vitro Validation Study. Journal of Biomechanical Engineering. PMID 26974192 DOI: 10.1115/1.4032995  0.44
2015 Zhao KD, Van Straaten MG, Cloud BA, Morrow MM, An KN, Ludewig PM. Scapulothoracic and Glenohumeral Kinematics During Daily Tasks in Users of Manual Wheelchairs. Frontiers in Bioengineering and Biotechnology. 3: 183. PMID 26636073 DOI: 10.3389/fbioe.2015.00183  0.44
2015 Zhao C, Hongo M, Ilharreborde B, Zhao KD, Currier BL, An KN. Trans-Endplate Pedicle Pillar System in Unstable Spinal Burst Fractures: Design, Technique, and Mechanical Evaluation. Plos One. 10: e0139592. PMID 26502352 DOI: 10.1371/journal.pone.0139592  0.88
2015 Hatta T, Giambini H, Uehara K, Okamoto S, Chen S, Sperling JW, Itoi E, An KN. Quantitative assessment of rotator cuff muscle elasticity: Reliability and feasibility of shear wave elastography. Journal of Biomechanics. PMID 26472309 DOI: 10.1016/j.jbiomech.2015.09.038  0.88
2015 Chen X, Giambini H, Ben-Abraham E, An KN, Nassr A, Zhao C. Effect of Bone Mineral Density on Rotator Cuff Tear: An Osteoporotic Rabbit Model. Plos One. 10: e0139384. PMID 26466092 DOI: 10.1371/journal.pone.0139384  0.88
2015 Ellingson AM, Shaw MN, Giambini H, An KN. Comparative role of disc degeneration and ligament failure on functional mechanics of the lumbar spine. Computer Methods in Biomechanics and Biomedical Engineering. 1-10. PMID 26404463 DOI: 10.1080/10255842.2015.1088524  0.88
2015 Omi R, Gingery A, Steinmann SP, Amadio PC, An KN, Zhao C. Rotator cuff repair augmentation in a rat model that combines a multilayer xenograft tendon scaffold with bone marrow stromal cells. Journal of Shoulder and Elbow Surgery / American Shoulder and Elbow Surgeons ... [Et Al.]. PMID 26387915 DOI: 10.1016/j.jse.2015.08.008  0.88
2015 Giambini H, Dragomir-Daescu D, Huddleston PM, Camp JJ, An KN, Nassr A. The Effect of Quantitative Computed Tomography Acquisition Protocols on Bone Mineral Density Estimation. Journal of Biomechanical Engineering. 137. PMID 26355694 DOI: 10.1115/1.4031572  0.88
2015 Yang TH, Thoreson AR, An KN, Zhao C, Conover CA, Amadio PC. PAPP-A affects tendon structure and mechanical properties. Journal of Structural Biology. PMID 26306763 DOI: 10.1016/j.jsb.2015.08.012  0.88
2015 Giambini H, Qin X, Dragomir-Daescu D, An KN, Nassr A. Specimen-specific vertebral fracture modeling: a feasibility study using the extended finite element method. Medical & Biological Engineering & Computing. PMID 26239163 DOI: 10.1007/s11517-015-1348-x  0.88
2015 Rappaport PO, Thoreson AR, Yang TH, Reisdorf RL, Rappaport SM, An KN, Amadio PC. Effect of wrist and interphalangeal thumb movement on zone T2 flexor pollicis longus tendon tension in a human cadaver model. Journal of Hand Therapy : Official Journal of the American Society of Hand Therapists. PMID 26209161 DOI: 10.1016/j.jht.2015.04.002  0.88
2015 Ji X, Bao N, An KN, Amadio PC, Steinmann SP, Zhao C. A Canine Non-Weight-Bearing Model with Radial Neurectomy for Rotator Cuff Repair. Plos One. 10: e0130576. PMID 26107616 DOI: 10.1371/journal.pone.0130576  0.88
2015 Zhao K, Breighner R, Holmes D, Leng S, McCollough C, An KN. A technique for quantifying wrist motion using four-dimensional computed tomography: approach and validation. Journal of Biomechanical Engineering. 137. PMID 25901447 DOI: 10.1115/1.4030405  0.88
2015 Wu JZ, Sinsel EW, Zhao KD, An KN, Buczek FL. Analysis of the Constraint Joint Loading in the Thumb During Pipetting. Journal of Biomechanical Engineering. 137. PMID 25839321 DOI: 10.1115/1.4030311  0.88
2015 Brandenburg JE, Eby SF, Song P, Zhao H, Landry BW, Kingsley-Berg S, Bamlet WR, Chen S, Sieck GC, An KN. Feasibility and reliability of quantifying passive muscle stiffness in young children by using shear wave ultrasound elastography. Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine. 34: 663-70. PMID 25792582 DOI: 10.7863/ultra.34.4.663  0.88
2015 Wu J, Thoreson AR, Reisdorf RL, An KN, Moran SL, Amadio PC, Zhao C. Biomechanical evaluation of flexor tendon graft with different repair techniques and graft surface modification. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 33: 731-7. PMID 25665071 DOI: 10.1002/jor.22844  0.88
2015 Yang TH, Thoreson AR, Gingery A, Larson DR, Passe SM, An KN, Zhao C, Amadio PC. Collagen gel contraction as a measure of fibroblast function in an animal model of subsynovial connective tissue fibrosis. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 33: 668-74. PMID 25626430 DOI: 10.1002/jor.22835  0.88
2015 Bachman DR, Thaveepunsan S, Park S, Fitzsimmons JS, An KN, O'Driscoll SW. The effect of prosthetic radial head geometry on the distribution and magnitude of radiocapitellar joint contact pressures. The Journal of Hand Surgery. 40: 281-8. PMID 25542439 DOI: 10.1016/j.jhsa.2014.11.005  0.88
2015 Shukla DR, Thoreson AR, Fitzsimmons JS, An KN, O'Driscoll SW. The effect of capitellar impaction fractures on radiocapitellar stability. The Journal of Hand Surgery. 40: 520-5. PMID 25510156 DOI: 10.1016/j.jhsa.2014.10.031  0.88
2015 Eby SF, Cloud BA, Brandenburg JE, Giambini H, Song P, Chen S, LeBrasseur NK, An KN. Shear wave elastography of passive skeletal muscle stiffness: influences of sex and age throughout adulthood. Clinical Biomechanics (Bristol, Avon). 30: 22-7. PMID 25483294 DOI: 10.1016/j.clinbiomech.2014.11.011  0.88
2015 Matsuura Y, Kuniyoshi K, Suzuki T, Ogawa Y, Sukegawa K, Rokkaku T, Thoreson AR, An KN, Takahashi K. Accuracy of specimen-specific nonlinear finite element analysis for evaluation of radial diaphysis strength in cadaver material. Computer Methods in Biomechanics and Biomedical Engineering. 18: 1811-7. PMID 25374112 DOI: 10.1080/10255842.2014.974579  0.88
2015 Loyd AM, Berglund L, Twardowski CP, Stuart MB, Smith AM, Gaz DV, Krause DA, An KN, Stuart MJ. The most cut-resistant neck guard for preventing lacerations to the neck. Clinical Journal of Sport Medicine : Official Journal of the Canadian Academy of Sport Medicine. 25: 254-9. PMID 24949830 DOI: 10.1097/JSM.0000000000000121  0.88
2015 Yang TH, Thoreson AR, Gingery A, An KN, Larson DR, Zhao C, Amadio PC. Collagen gel contraction as a measure of fibroblast function in carpal tunnel syndrome. Journal of Biomedical Materials Research. Part A. 103: 574-80. PMID 24753289 DOI: 10.1002/jbm.a.35200  0.88
2014 Mat Jais IS, Liu X, An KN, Tay SC. A method for carpal motion hysteresis quantification in 4-dimensional imaging of the wrist. Medical Engineering & Physics. 36: 1699-703. PMID 25277831 DOI: 10.1016/j.medengphy.2014.08.011  0.88
2014 Matsuura Y, Giambini H, Ogawa Y, Fang Z, Thoreson AR, Yaszemski MJ, Lu L, An KN. Specimen-specific nonlinear finite element modeling to predict vertebrae fracture loads after vertebroplasty. Spine. 39: E1291-6. PMID 25077904 DOI: 10.1097/BRS.0000000000000540  0.88
2014 Brandenburg JE, Eby SF, Song P, Zhao H, Brault JS, Chen S, An KN. Ultrasound elastography: the new frontier in direct measurement of muscle stiffness. Archives of Physical Medicine and Rehabilitation. 95: 2207-19. PMID 25064780 DOI: 10.1016/j.apmr.2014.07.007  0.88
2014 Cloud BA, Zhao KD, Breighner R, Giambini H, An KN. Agreement between fiber optic and optoelectronic systems for quantifying sagittal plane spinal curvature in sitting. Gait & Posture. 40: 369-74. PMID 24909579 DOI: 10.1016/j.gaitpost.2014.05.007  0.88
2014 Sahu D, Holmes DM, Fitzsimmons JS, Thoreson AR, Berglund LJ, An KN, O'Driscoll SW. Influence of radial head prosthetic design on radiocapitellar joint contact mechanics. Journal of Shoulder and Elbow Surgery / American Shoulder and Elbow Surgeons ... [Et Al.]. 23: 456-62. PMID 24630544 DOI: 10.1016/j.jse.2013.11.028  0.88
2014 Giambini H, Salman Roghani R, Thoreson AR, Melton LJ, An KN, Gay RE. Lumbar trabecular bone mineral density distribution in patients with and without vertebral fractures: a case-control study. European Spine Journal : Official Publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 23: 1346-53. PMID 24477380 DOI: 10.1007/s00586-014-3205-2  0.88
2014 Zhao C, Wei Z, Reisdorf RL, Thoreson AR, Jay GD, Moran SL, An KN, Amadio PC. The effects of biological lubricating molecules on flexor tendon reconstruction in a canine allograft model in vivo. Plastic and Reconstructive Surgery. 133: 628e-637e. PMID 24445876 DOI: 10.1097/PRS.0000000000000102  0.88
2014 Omi R, Hooke AW, Zhao KD, Matsuhashi T, Goto A, Yamamoto N, Sperling JW, Steinmann SP, Itoi E, An KN. The effect of the remplissage procedure on shoulder range of motion: a cadaveric study. Arthroscopy : the Journal of Arthroscopic & Related Surgery : Official Publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 30: 178-87. PMID 24388452 DOI: 10.1016/j.arthro.2013.11.003  0.88
2014 Wu JZ, Sinsel EW, Shroyer JF, Warren CM, Welcome DE, Zhao KD, An KN, Buczek FL. Analysis of the musculoskeletal loading of the thumb during pipetting--a pilot study. Journal of Biomechanics. 47: 392-9. PMID 24290720 DOI: 10.1016/j.jbiomech.2013.11.015  0.88
2014 Fang Z, Giambini H, Zeng H, Camp JJ, Dadsetan M, Robb RA, An KN, Yaszemski MJ, Lu L. Biomechanical evaluation of an injectable and biodegradable copolymer P(PF-co-CL) in a cadaveric vertebral body defect model. Tissue Engineering. Part A. 20: 1096-102. PMID 24256208 DOI: 10.1089/ten.TEA.2013.0275  0.88
2014 Matsuhashi T, Hooke AW, Zhao KD, Goto A, Sperling JW, Steinmann SP, An KN. Tensile properties of a morphologically split supraspinatus tendon. Clinical Anatomy (New York, N.Y.). 27: 702-6. PMID 24214830 DOI: 10.1002/ca.22322  0.88
2014 Shukla D, Fitzsimmons J, An KN, O'Driscoll S. Prosthetic radial head stem pull-out as a mode of failure: a biomechanical study. International Orthopaedics. 38: 89-93. PMID 24042697 DOI: 10.1007/s00264-013-2074-3  0.88
2013 Breighner R, Holmes DR, Leng S, An KN, McCollough C, Zhao K. 3D-3D Registration of partial capitate bones using spin-images. Proceedings of Spie--the International Society For Optical Engineering. 8671. PMID 28620247 DOI: 10.1117/12.2008685  0.44
2013 Matsuhashi T, Hooke AW, Zhao KD, Sperling JW, Steinmann SP, An KN. Effect of humeral head rotation on bony glenohumeral stability. Clinical Biomechanics (Bristol, Avon). 28: 961-6. PMID 24135199 DOI: 10.1016/j.clinbiomech.2013.09.011  0.88
2013 Wu JZ, Sinsel EW, Shroyer JF, Welcome DE, Zhao KD, An KN, Buczek FL. The musculoskeletal loading profile of the thumb during pipetting based on tendon displacement. Medical Engineering & Physics. 35: 1801-10. PMID 24018066 DOI: 10.1016/j.medengphy.2013.08.004  0.88
2013 Shukla DR, Shao D, Fitzsimmons JS, Thoreson AR, An KN, O'Driscoll SW. Canal preparation for prosthetic radial head replacement: rasping versus reaming. Journal of Shoulder and Elbow Surgery / American Shoulder and Elbow Surgeons ... [Et Al.]. 22: 1474-9. PMID 24012361 DOI: 10.1016/j.jse.2013.06.015  0.88
2013 Vanhees M, Thoreson AR, Amadio PC, An KN, Zhao C, Larson DR. In reply. The Journal of Hand Surgery. 38: 1661. PMID 23890508 DOI: 10.1016/j.jhsa.2013.05.031  0.88
2013 Neo PY, Mat Jais IS, Panknin C, Lau CC, Chan LP, An KN, Tay SC. Dynamic imaging with dual-source gated Computed Tomography (CT): implications of motion parameters on image quality for wrist imaging. Medical Engineering & Physics. 35: 1837-42. PMID 23773336 DOI: 10.1016/j.medengphy.2013.05.009  0.88
2013 Wegrzyn J, Thoreson AR, Guyen O, Lewallen DG, An KN. Cementation of a dual-mobility acetabular component into a well-fixed metal shell during revision total hip arthroplasty: a biomechanical validation. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 31: 991-7. PMID 23335343 DOI: 10.1002/jor.22314  0.32
2013 Dhima M, Assad DA, Volz JE, An KN, Berglund LJ, Carr AB, Salinas TJ. Evaluation of fracture resistance in aqueous environment of four restorative systems for posterior applications. Part 1. Journal of Prosthodontics : Official Journal of the American College of Prosthodontists. 22: 256-60. PMID 23279080 DOI: 10.1111/j.1532-849X.2012.00948.x  0.88
2013 Vanhees M, Thoreson AR, Larson DR, Amadio PC, An KN, Zhao C. The effect of suture preloading on the force to failure and gap formation after flexor tendon repair. The Journal of Hand Surgery. 38: 56-61. PMID 23261189 DOI: 10.1016/j.jhsa.2012.09.030  0.88
2013 Giambini H, Wang HJ, Zhao C, Chen Q, Nassr A, An KN. Anterior and posterior variations in mechanical properties of human vertebrae measured by nanoindentation. Journal of Biomechanics. 46: 456-61. PMID 23182219 DOI: 10.1016/j.jbiomech.2012.11.008  0.88
2013 Giambini H, Khosla S, Nassr A, Zhao C, An KN. Longitudinal changes in lumbar bone mineral density distribution may increase the risk of wedge fractures. Clinical Biomechanics (Bristol, Avon). 28: 10-4. PMID 23142501 DOI: 10.1016/j.clinbiomech.2012.10.005  0.88
2013 McGee-Lawrence ME, Bradley EW, Dudakovic A, Carlson SW, Ryan ZC, Kumar R, Dadsetan M, Yaszemski MJ, Chen Q, An KN, Westendorf JJ. Histone deacetylase 3 is required for maintenance of bone mass during aging. Bone. 52: 296-307. PMID 23085085 DOI: 10.1016/j.bone.2012.10.015  0.88
2013 Watanabe K, Kitaoka HB, Fujii T, Crevoisier X, Berglund LJ, Zhao KD, Kaufman KR, An KN. Posterior tibial tendon dysfunction and flatfoot: analysis with simulated walking. Gait & Posture. 37: 264-8. PMID 22939754 DOI: 10.1016/j.gaitpost.2012.07.015  0.88
2013 Yamamoto N, Hongo M, Berglund LJ, Sperling JW, Cofield RH, An KN, Steinmann SP. Biomechanical analysis of a novel locking plate with smooth pegs versus a conventional locking plate with threaded screws for proximal humerus fractures. Journal of Shoulder and Elbow Surgery / American Shoulder and Elbow Surgeons ... [Et Al.]. 22: 445-50. PMID 22743070 DOI: 10.1016/j.jse.2012.04.005  0.4
2012 Chanlalit C, Shukla DR, Fitzsimmons JS, An KN, O'Driscoll SW. Stress shielding around radial head prostheses. The Journal of Hand Surgery. 37: 2118-25. PMID 23021176 DOI: 10.1016/j.jhsa.2012.06.020  0.88
2012 Wang HJ, Giambini H, Zhang WJ, Ye GH, Zhao C, An KN, Li YK, Lan WR, Li JY, Jiang XS, Zou QL, Zhang XY, Chen C. A modified sagittal spine postural classification and its relationship to deformities and spinal mobility in a chinese osteoporotic population. Plos One. 7: e38560. PMID 22693647 DOI: 10.1371/journal.pone.0038560  0.88
2012 Shukla DR, Fitzsimmons JS, An KN, O'Driscoll SW. Effect of radial head malunion on radiocapitellar stability. Journal of Shoulder and Elbow Surgery / American Shoulder and Elbow Surgeons ... [Et Al.]. 21: 789-94. PMID 22521392 DOI: 10.1016/j.jse.2011.12.001  0.88
2012 Shukla DR, Fitzsimmons JS, An KN, O'Driscoll SW. Effect of stem length on prosthetic radial head micromotion. Journal of Shoulder and Elbow Surgery / American Shoulder and Elbow Surgeons ... [Et Al.]. 21: 1559-64. PMID 22445160 DOI: 10.1016/j.jse.2011.11.025  0.88
2011 Ilharreborde B, Shaw MN, Berglund LJ, Zhao KD, Gay RE, An KN. Biomechanical evaluation of posterior lumbar dynamic stabilization: an in vitro comparison between Universal Clamp and Wallis systems. European Spine Journal : Official Publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 20: 289-96. PMID 21132335 DOI: 10.1007/s00586-010-1641-1  0.88
2011 An KN. Computational modeling of ligaments and tendons a tribute to Dr. Savio Lau-Yuen Woo Asme 2011 Summer Bioengineering Conference, Sbc 2011. 653-654. DOI: 10.1115/SBC2011-53061  0.88
2010 Giambini H, Ikeda J, Amadio PC, An KN, Zhao C. The quadriga effect revisited: designing a "safety incision" to prevent tendon repair rupture and gap formation in a canine model in vitro. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 28: 1482-9. PMID 20872585 DOI: 10.1002/jor.21168  0.88
2010 Berkhout MJ, Shaw MN, Berglund LJ, An KN, Berger RA, Ritt MJ. The effect of radioscapholunate fusion on wrist movement and the subsequent effects of distal scaphoidectomy and triquetrectomy. The Journal of Hand Surgery, European Volume. 35: 740-5. PMID 20427404 DOI: 10.1177/1753193410370926  0.88
2007 An KN. Tendon excursion and gliding: Clinical impacts from humble concepts Journal of Biomechanics. 40: 713-718. PMID 17092508 DOI: 10.1016/j.jbiomech.2006.10.008  0.88
2005 An KN. Kinematics and constraint of total elbow arthroplasty Journal of Shoulder and Elbow Surgery. 14. PMID 15726077 DOI: 10.1016/j.jse.2004.09.035  0.88
2005 An KN. Role of biomechanics in functional tissue engineering Materials Research Society Symposium Proceedings. 844: 187-193.  0.88
2002 An KN. Muscle force and its role in joint dynamic stability Clinical Orthopaedics and Related Research. PMID 12394451  0.88
2002 Lee SB, An KN. Dynamic glenohumeral stability provided by three heads of the deltoid muscle Clinical Orthopaedics and Related Research. 40-47. PMID 12072744  0.88
2001 Luo ZP, An KN. Fuzzy systems in biomedical science International Journal of General Systems. 30: 209-217.  0.88
1998 Luo ZP, An KN. Development and validation of a nanometer manipulation and measurement system for biomechanical testing of single macro-molecules Journal of Biomechanics. 31: 1075-1079. PMID 9880066 DOI: 10.1016/S0021-9290(98)00128-6  0.88
1998 Luo ZP, An KN. Development and calibration of a nanometer manipulation and measurement system for molecular biomechanical testing American Society of Mechanical Engineers, Bioengineering Division (Publication) Bed. 39: 221-222.  0.88
1997 Hughes RE, An KN. Monte Carlo simulation of a planar shoulder model Medical & Biological Engineering & Computing. 35: 544-548. PMID 9374062 DOI: 10.1007/BF02525538  0.88
1994 Werner FW, An KN. Biomechanics of the elbow and forearm Hand Clinics. 10: 357-373. PMID 7962143  0.88
1994 Johnson ME, An KN. Chapter 13 Biomechanical Analysis of Reach and Grasp Advances in Psychology. 105: 269-279. DOI: 10.1016/S0166-4115(08)61282-0  0.88
1993 An KN. The effect of force transmission on the carpus after procedures used to treat Kienbock's disease Hand Clinics. 9: 445-454. PMID 8408254  0.88
1991 An KN. [73] Force and stability analysis of the human elbow Journal of Rehabilitation Research and Development. 28: 61-62.  0.88
1990 An KN, Bejjani FJ. Analysis of upper-extremity performance in athletes and musicians Hand Clinics. 6: 393-403. PMID 2211852  0.88
1985 Morrey BF, An KN. Functional anatomy of the ligaments of the elbow Clinical Orthopaedics and Related Research. 84-90. PMID 4064425  0.88
1984 An KN. Kinematic analysis of human movement Annals of Biomedical Engineering. 12: 585-597. PMID 6534225 DOI: 10.1007/BF02371451  0.88
1977 Chao EY, An KN. GRAPHICAL INTERPRETATION OF THE SOLUTION TO THE REDUNDANT PROBLEM IN BIOMECHANICS American Society of Mechanical Engineers (Paper) 0.88
1976 Salathe EP, An KN. A mathematical analysis of fluid movement across capillary walls Microvascular Research. 11: 1-23. PMID 1263857 DOI: 10.1016/0026-2862(76)90072-8  0.88
1976 An KN, Salathe EP. The effect of variable capillary radius and filtration coefficient on fluid exchange Biorheology. 13: 367-378. PMID 1009241  0.88
1976 An KN, Salathe EP. A theory of interstitial fluid motion and its implications for capillary exchange Microvascular Research. 12: 103-119. PMID 979663 DOI: 10.1016/0026-2862(76)90012-1  0.88
Show low-probability matches.