Year |
Citation |
Score |
2023 |
Liao W, Winship D, Lara-Ibeas I, Zhao X, Xu Q, Lu HT, Qian T, Gordenker R, Qin Y, Gianchandani YB. Highly Integrated μGC Based on a Multisensing Progressive Cellular Architecture with a Valveless Sample Inlet. Analytical Chemistry. 95: 2157-2167. PMID 36637876 DOI: 10.1021/acs.analchem.2c01818 |
0.553 |
|
2021 |
Liao W, Zhao X, Lu HT, Byambadorj T, Qin Y, Gianchandani YB. Progressive Cellular Architecture in Microscale Gas Chromatography for Broad Chemical Analyses. Sensors (Basel, Switzerland). 21. PMID 33946637 DOI: 10.3390/s21093089 |
0.77 |
|
2019 |
Benken A, Gianchandani Y. Passive Wireless Pressure Sensing for Gastric Manometry. Micromachines. 10: 868. PMID 31835529 DOI: 10.3390/Mi10120868 |
0.345 |
|
2019 |
Jiang J, Green SR, Gianchandani YB. Thermoformed Liquid Crystal Polymer Packages for Magnetoelastic Frame-Suspended Resonators Journal of Microelectromechanical Systems. 28: 532-539. DOI: 10.1109/Jmems.2019.2904711 |
0.63 |
|
2018 |
Jiang J, Nambisan RM, Green S, Gianchandani YB. Encapsulation Approaches for In-Stent Wireless Magnetoelastic Sensors. Ieee Transactions On Bio-Medical Engineering. PMID 30475708 DOI: 10.1109/Tbme.2018.2882415 |
0.615 |
|
2018 |
Deng S, Green SR, Gianchandani YB. A Micromachined Magnet-Less RF Electron Trap Journal of Microelectromechanical Systems. 27: 487-496. DOI: 10.1109/Jmems.2018.2818944 |
0.611 |
|
2018 |
Luo X, Gianchandani YB. A Microdischarge-Based Pressure Sensor Fabricated Using Through-Wafer Isolated Bulk-Silicon Lead Transfer Ieee\/Asme Journal of Microelectromechanical Systems. 27: 365-373. DOI: 10.1109/Jmems.2018.2805772 |
0.367 |
|
2018 |
Deng S, Green SR, Gianchandani YB. A 3D-printed miniature magnetron gauge for ultra-high vacuum environments Vacuum. 156: 264-270. DOI: 10.1016/J.Vacuum.2018.07.039 |
0.631 |
|
2017 |
Choi M, Sui Y, Lee IH, Meredith R, Ma Y, Kim G, Blaauw D, Gianchandani YB, Li T. Autonomous Microsystems for Downhole Applications: Design Challenges, Current State, and Initial Test Results. Sensors (Basel, Switzerland). 17. PMID 28946614 DOI: 10.3390/S17102190 |
0.367 |
|
2017 |
Pepakayala V, Green SR, Gianchandani YB. Wireless Strain Measurement with a Micromachined Magnetoelastic Resonator Using Ringdown Frequency Locking. Isss Journal of Micro and Smart Systems. 6: 3-13. PMID 28713873 DOI: 10.1007/s41683-017-0001-3 |
0.567 |
|
2017 |
Green SR, Gianchandani YB. Wireless magnetoelastic transducers for biomedical applications Proceedings of Spie. 10194: 1019412. DOI: 10.1117/12.2263677 |
0.633 |
|
2017 |
Deng S, Green SR, Markosyan AH, Kushner MJ, Gianchandani YB. Miniaturized magnet-less RF electron trap. II. Experimental verification Journal of Vacuum Science & Technology B, Nanotechnology and Microelectronics: Materials, Processing, Measurement, and Phenomena. 35: 042002. DOI: 10.1116/1.4984752 |
0.601 |
|
2017 |
Markosyan AH, Green SR, Deng S, Gianchandani YB, Kushner MJ. Miniaturized magnet-less RF electron trap. I. Modeling and analysis Journal of Vacuum Science & Technology B, Nanotechnology and Microelectronics: Materials, Processing, Measurement, and Phenomena. 35: 042001. DOI: 10.1116/1.4984751 |
0.586 |
|
2016 |
Qin Y, Gianchandani YB. A fully electronic microfabricated gas chromatograph with complementary capacitive detectors for indoor pollutants. Microsystems & Nanoengineering. 2: 15049. PMID 31057813 DOI: 10.1038/Micronano.2015.49 |
0.336 |
|
2016 |
Ma Y, Li T, Gianchandani YB. A Low-Temperature Batch Mode Packaging Process for Submillimeter Microsystems in Harsh Environment Applications Ieee Transactions On Components, Packaging and Manufacturing Technology. 6: 366-372. DOI: 10.1109/Tcpmt.2016.2521580 |
0.336 |
|
2016 |
Luo X, Gianchandani YB. A 100μm diameter capacitive pressure sensor with 50 MPa dynamic range Journal of Micromechanics and Microengineering. 26: 045009. DOI: 10.1088/0960-1317/26/4/045009 |
0.356 |
|
2015 |
Malhotra R, Gianchandani YB. A Microdischarge-Based Neutron Radiation Detector Utilizing a Stacked Arrangement of Micromachined Steel Electrodes With Gadolinium Film for Neutron Conversion Ieee Sensors Journal. 15: 3863-3870. DOI: 10.1109/Jsen.2015.2397006 |
0.327 |
|
2015 |
An S, Qin Y, Gianchandani YB. A Monolithic High-Flow Knudsen Pump Using Vertical Al₂O₃ Channels in SOI Journal of Microelectromechanical Systems. DOI: 10.1109/Jmems.2015.2426699 |
0.358 |
|
2015 |
Malhotra R, Gianchandani YB. A Gamma Radiation Detector With Orthogonally Arrayed Micromachined Electrodes Ieee\/Asme Journal of Microelectromechanical Systems. 24: 1314-1321. DOI: 10.1109/Jmems.2015.2394322 |
0.343 |
|
2015 |
Tang J, Green SR, Gianchandani YB. A fabrication process for the monolithic integration of magnetoelastic actuators and silicon sensors Journal of Micromechanics and Microengineering. 25. DOI: 10.1088/0960-1317/25/4/045001 |
0.62 |
|
2015 |
Jeong H, Li T, Gianchandani YB, Park J. High precision cell slicing by harmonically actuated ultra-sharp SixNy blades Journal of Micromechanics and Microengineering. 25: 25007. DOI: 10.1088/0960-1317/25/2/025007 |
0.336 |
|
2015 |
Qin Y, An S, Gianchandani YB. Arrayed architectures for multi-stage Si-micromachined high-flow Knudsen pumps Journal of Micromechanics and Microengineering. 25. DOI: 10.1088/0960-1317/25/11/115026 |
0.358 |
|
2015 |
Pepakayala V, Stein J, Gianchandani Y. Resonant magnetoelastic microstructures for wireless actuation of liquid flow on 3D surfaces and use in glaucoma drainage implants Microsystems & Nanoengineering. 1: 15032. DOI: 10.1038/Micronano.2015.32 |
0.375 |
|
2015 |
Qu J, Tang J, Gianchandani YB, Oldham KR, Green SR. Dynamic modeling of a bidirectional magnetoelastic rotary micro-motor Sensors and Actuators, a: Physical. 223: 49-60. DOI: 10.1016/J.Sna.2014.12.029 |
0.568 |
|
2015 |
Nakaye S, Sugimoto H, Gupta NK, Gianchandani YB. Thermally enhanced membrane gas separation European Journal of Mechanics - B/Fluids. 49: 36-49. DOI: 10.1016/J.Euromechflu.2014.07.004 |
0.563 |
|
2014 |
An S, Gupta NK, Gianchandani YB. Vacuum sealing using atomic layer deposition of Al2O3 at 250 °C Journal of Vacuum Science & Technology a: Vacuum, Surfaces, and Films. 32: 01A101. DOI: 10.1116/1.4820240 |
0.551 |
|
2014 |
Ma Y, Sui Y, Li T, Gianchandani YB. A Submillimeter Package for Microsystems in High-Pressure and High-Salinity Downhole Environments Journal of Microelectromechanical Systems. DOI: 10.1109/Jmems.2014.2355191 |
0.351 |
|
2014 |
Pepakayala V, Green SR, Gianchandani YB. Passive wireless strain sensors using microfabricated magnetoelastic beam elements Journal of Microelectromechanical Systems. 23: 1374-1382. DOI: 10.1109/Jmems.2014.2313809 |
0.615 |
|
2014 |
Eun CK, Luo X, Wang JC, Xiong Z, Kushner M, Gianchandani Y. A microdischarge-based monolithic pressure sensor Journal of Microelectromechanical Systems. 23: 1300-1310. DOI: 10.1109/Jmems.2014.2312174 |
0.751 |
|
2014 |
Qin Y, Gianchandani YB. IGC1: An integrated fluidic system for gas chromatography including knudsen pump, preconcentrator, column, and detector microfabricated by a three-mask process Ieee\/Asme Journal of Microelectromechanical Systems. 23: 980-990. DOI: 10.1109/Jmems.2014.2306652 |
0.313 |
|
2014 |
Hendarto E, Gianchandani YB. Thermocapillary Actuation of Millimeter-Scale Rotary Structures Ieee\/Asme Journal of Microelectromechanical Systems. 23: 494-499. DOI: 10.1109/Jmems.2013.2281328 |
0.785 |
|
2014 |
An S, Gianchandani YB. A Dynamic Calibration Method for Pirani Gauges Embedded in Fluidic Networks Ieee\/Asme Journal of Microelectromechanical Systems. 23: 699-709. DOI: 10.1109/Jmems.2013.2281319 |
0.311 |
|
2014 |
An S, Gupta NK, Gianchandani YB. A Si-Micromachined 162-Stage Two-Part Knudsen Pump for On-Chip Vacuum Ieee\/Asme Journal of Microelectromechanical Systems. 23: 406-416. DOI: 10.1109/Jmems.2013.2281316 |
0.573 |
|
2014 |
Viswanath A, Li T, Gianchandani Y. High resolution micro ultrasonic machining for trimming 3D microstructures Journal of Micromechanics and Microengineering. 24. DOI: 10.1088/0960-1317/24/6/065017 |
0.303 |
|
2014 |
Qin Y, Gianchandani YB. iGC2: an architecture for micro gas chromatographs utilizing integrated bi-directional pumps and multi-stage preconcentrators Journal of Micromechanics and Microengineering. 24: 65011. DOI: 10.1088/0960-1317/24/6/065011 |
0.325 |
|
2014 |
Tang J, Green SR, Gianchandani YB. Scalable, high-performance magnetoelastic tags using frame-suspended hexagonal resonators Journal of Micromechanics and Microengineering. 24. DOI: 10.1088/0960-1317/24/6/065006 |
0.614 |
|
2014 |
Li T, Visvanathan K, Gianchandani YB. A batch-mode micromachining process for spherical structures Journal of Micromechanics and Microengineering. 24. DOI: 10.1088/0960-1317/24/2/025002 |
0.775 |
|
2013 |
Green SR, Kwon RS, Elta GH, Gianchandani YB. In vivo and in situ evaluation of a wireless magnetoelastic sensor array for plastic biliary stent monitoring. Biomedical Microdevices. 15: 509-17. PMID 23460136 DOI: 10.1007/S10544-013-9750-3 |
0.621 |
|
2013 |
Viswanath A, Green SR, Kosel J, Gianchandani YB. Conformally integrated stent cell resonators for wireless monitoring of peripheral artery disease Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 1069-1072. DOI: 10.1109/MEMSYS.2013.6474434 |
0.523 |
|
2013 |
Luo X, Gianchandani YB. A Pulsed High-Voltage Generator Utilizing a Monolithic PZT Element and Evaluation of Nonlinear Piezoelectric Behavior in Transient Mode Ieee\/Asme Journal of Microelectromechanical Systems. 22: 930-937. DOI: 10.1109/Jmems.2013.2250487 |
0.359 |
|
2013 |
Tang J, Green SR, Gianchandani YB. Miniature wireless magnetoelastic resonant motor with frequency selectable bidirectional rotation Journal of Microelectromechanical Systems. 22: 730-738. DOI: 10.1109/Jmems.2013.2242253 |
0.618 |
|
2013 |
Green SR, Malhotra R, Gianchandani YB. Sub-torr chip-scale sputter-ion pump based on a penning cell array architecture Journal of Microelectromechanical Systems. 22: 309-317. DOI: 10.1109/Jmems.2012.2221159 |
0.624 |
|
2013 |
Wright SA, Harvey HZ, Gianchandani YB. A microdischarge-based deflecting-cathode pressure sensor in a ceramic package Journal of Microelectromechanical Systems. 22: 80-86. DOI: 10.1109/Jmems.2012.2215009 |
0.393 |
|
2013 |
Li T, Bai Q, Gianchandani YB. High precision batch mode micro-electro-discharge machining of metal alloys using DRIE silicon as a cutting tool Journal of Micromechanics and Microengineering. 23: 95026. DOI: 10.1088/0960-1317/23/9/095026 |
0.311 |
|
2013 |
Hendarto E, Gianchandani YB. Size sorting of floating spheres based on Marangoni forces in evaporating droplets Journal of Micromechanics and Microengineering. 23: 075016. DOI: 10.1088/0960-1317/23/7/075016 |
0.775 |
|
2013 |
Hendarto E, Li T, Gianchandani YB. Investigation of wine glass mode resonance in 200-µm-diameter cenosphere-derived borosilicate hemispherical shells Journal of Micromechanics and Microengineering. 23: 055013. DOI: 10.1088/0960-1317/23/5/055013 |
0.794 |
|
2013 |
Viswanath A, Green SR, Kosel J, Gianchandani YB. Metglas-Elgiloy bi-layer, stent cell resonators for wireless monitoring of viscosity and mass loading Journal of Micromechanics and Microengineering. 23. DOI: 10.1088/0960-1317/23/2/025010 |
0.617 |
|
2012 |
Li T, Evans AT, Chiravuri S, Gianchandani RY, Gianchandani YB. Compact, power-efficient architectures using microvalves and microsensors, for intrathecal, insulin, and other drug delivery systems. Advanced Drug Delivery Reviews. 64: 1639-49. PMID 22580183 DOI: 10.1016/J.Addr.2012.05.002 |
0.323 |
|
2012 |
Liu J, Khaing Oo MK, Reddy K, Gianchandani YB, Schultz JC, Appel HM, Fan X. Adaptive two-dimensional microgas chromatography. Analytical Chemistry. 84: 4214-20. PMID 22468727 DOI: 10.1021/Ac300588Z |
0.307 |
|
2012 |
Visvanathan K, Li T, Gianchandani YB. A biopsy tool with integrated piezoceramic elements for needle tract cauterization and cauterization monitoring. Biomedical Microdevices. 14: 55-65. PMID 21898007 DOI: 10.1007/S10544-011-9585-8 |
0.791 |
|
2012 |
Ozkeskin FM, Choi S, Sarabandi K, Gianchandani YB. An All-Metal Micro-Relay With Bulk Foil Pt–Rh Contacts for High-Power RF Applications Ieee Transactions On Microwave Theory and Techniques. 60: 1595-1604. DOI: 10.1109/Tmtt.2012.2192744 |
0.787 |
|
2012 |
Eun CK, Gianchandani YB. Microdischarge-Based Sensors and Actuators for Portable Microsystems: Selected Examples Ieee Journal of Quantum Electronics. 48: 814-826. DOI: 10.1109/Jqe.2012.2189199 |
0.748 |
|
2012 |
Ozkeskin FM, Choi S, Sarabandi K, Gianchandani YB. Batch-Fabricated High-Power RF Microrelays With Direct On-PCB Packages Journal of Microelectromechanical Systems. 21: 990-1001. DOI: 10.1109/Jmems.2012.2194772 |
0.782 |
|
2012 |
Gupta NK, An S, Gianchandani YB. A Si-micromachined 48-stage Knudsen pump for on-chip vacuum Journal of Micromechanics and Microengineering. 22: 105026. DOI: 10.1088/0960-1317/22/10/105026 |
0.598 |
|
2012 |
Alfadhel A, Gianchandani Y, Kosel J. Microfabrication of magnetostrictive beams based on NiFe film doped with B and Mo for integrated sensor systems Journal of Applied Physics. 111. DOI: 10.1063/1.3679016 |
0.344 |
|
2012 |
Ozkeskin FM, Gianchandani YB. Micromachined Pt–Rh and stainless steel relays for high power DC applications Sensors and Actuators a: Physical. 176: 130-137. DOI: 10.1016/J.Sna.2011.12.033 |
0.791 |
|
2011 |
Liu J, Gupta NK, Wise KD, Gianchandani YB, Fan X. Demonstration of motionless Knudsen pump based micro-gas chromatography featuring micro-fabricated columns and on-column detectors. Lab On a Chip. 11: 3487-92. PMID 21869988 DOI: 10.1039/C1Lc20511K |
0.673 |
|
2011 |
Zhu W, Park JM, White MJ, Nellis GF, Gianchandani YB. Experimental evaluation of an adaptive Joule-Thomson cooling system including silicon-microfabricated heat exchanger and microvalve components. Journal of Vacuum Science & Technology. a, Vacuum, Surfaces, and Films : An Official Journal of the American Vacuum Society. 29: 21005-210056. PMID 21552354 DOI: 10.1116/1.3545917 |
0.737 |
|
2011 |
Eun CK, Gianchandani YB. A Wireless-Enabled Microdischarge-Based Radiation Detector Utilizing Stacked Electrode Arrays for Enhanced Detection Efficiency Journal of Microelectromechanical Systems. 20: 636-643. DOI: 10.1109/Jmems.2011.2127461 |
0.738 |
|
2011 |
Evans AT, Chiravuri S, Gianchandani YB. A Multidrug Delivery System Using a Piezoelectrically Actuated Silicon Valve Manifold With Embedded Sensors Journal of Microelectromechanical Systems. 20: 231-238. DOI: 10.1109/Jmems.2010.2093566 |
0.357 |
|
2011 |
Gupta NK, Gianchandani YB. Porous ceramics for multistage Knudsen micropumps—modeling approach and experimental evaluation Journal of Micromechanics and Microengineering. 21: 095029. DOI: 10.1088/0960-1317/21/9/095029 |
0.575 |
|
2011 |
Visvanathan K, Gianchandani YB. Microheaters based on ultrasonic actuation of piezoceramic elements Journal of Micromechanics and Microengineering. 21. DOI: 10.1088/0960-1317/21/8/085030 |
0.784 |
|
2011 |
Visvanathan K, Gianchandani YB. Locomotion response of airborne, ambulatory and aquatic insects to thermal stimulation using piezoceramic microheaters Journal of Micromechanics and Microengineering. 21. DOI: 10.1088/0960-1317/21/12/125002 |
0.771 |
|
2011 |
Hendarto E, Gianchandani YB. A non-contact method for spatially localized sedimentation of particles from liquid suspensions using Marangoni forces Journal of Micromechanics and Microengineering. 21: 115028. DOI: 10.1088/0960-1317/21/11/115028 |
0.779 |
|
2011 |
Al Rowais H, Li B, Liang C, Green S, Gianchandani Y, Kosel J. Development of a passive and remote magnetic microsensor with thin-film giant magnetoimpedance element and surface acoustic wave transponder Journal of Applied Physics. 109: 07E524. DOI: 10.1063/1.3562041 |
0.616 |
|
2011 |
Gupta NK, Gianchandani YB. Thermal transpiration in mixed cellulose ester membranes: Enabling miniature, motionless gas pumps Microporous and Mesoporous Materials. 142: 535-541. DOI: 10.1016/J.Micromeso.2010.12.042 |
0.55 |
|
2010 |
White MJ, Nellis GF, Kelin SA, Zhu W, Gianchandani Y. An Experimentally Validated Numerical Modeling Technique for Perforated Plate Heat Exchangers. Journal of Heat Transfer. 132: 1-9. PMID 20976021 DOI: 10.1115/1.4000673 |
0.724 |
|
2010 |
Evans AT, Gianchandani YB. Note: A low leakage liquid seal for micromachined gas valves. The Review of Scientific Instruments. 81: 066105. PMID 20590276 DOI: 10.1063/1.3436642 |
0.31 |
|
2010 |
Zhu W, White MJ, Nellis GF, Klein SA, Gianchandani YB. A Si/Glass Bulk-Micromachined Cryogenic Heat Exchanger for High Heat Loads: Fabrication, Test, and Application Results. Journal of Microelectromechanical Systems : a Joint Ieee and Asme Publication On Microstructures, Microactuators, Microsensors, and Microsystems. 19: 38-47. PMID 20490284 DOI: 10.1109/Jmems.2009.2034322 |
0.723 |
|
2010 |
Green SR, Kwon RS, Elta GH, Gianchandani YB. In situ and ex vivo evaluation of a wireless magnetoelastic biliary stent monitoring system. Biomedical Microdevices. 12: 477-84. PMID 20180152 DOI: 10.1007/S10544-010-9404-7 |
0.613 |
|
2010 |
Evans AT, Chiravuri S, Gianchandani YB. Transdermal power transfer for recharging implanted drug delivery devices via the refill port. Biomedical Microdevices. 12: 179-85. PMID 19936931 DOI: 10.1007/S10544-009-9371-Z |
0.349 |
|
2010 |
Evans AT, Park JM, Chiravuri S, Gianchandani YB. A low power, microvalve regulated architecture for drug delivery systems. Biomedical Microdevices. 12: 159-68. PMID 19936930 DOI: 10.1007/S10544-009-9372-Y |
0.365 |
|
2010 |
Eun CK, Gharpurey R, Gianchandani YB. Wireless signaling of beta detection using microdischarges Journal of Microelectromechanical Systems. 19: 785-793. DOI: 10.1109/Jmems.2010.2055546 |
0.73 |
|
2010 |
Richardson MT, Gianchandani YB. Wireless Monitoring of Workpiece Material Transitions and Debris Accumulation in Micro-Electro-Discharge Machining Ieee\/Asme Journal of Microelectromechanical Systems. 19: 48-54. DOI: 10.1109/Jmems.2009.2035642 |
0.323 |
|
2010 |
Eun CK, Gianchandani YB. A microfabricated steel and glass radiation detector with inherent wireless signaling Journal of Micromechanics and Microengineering. 21: 015003. DOI: 10.1088/0960-1317/21/1/015003 |
0.733 |
|
2010 |
Green SR, Gianchandani YB. Tailored magnetoelastic sensor geometry for advanced functionality in wireless biliary stent monitoring systems Journal of Micromechanics and Microengineering. 20. DOI: 10.1088/0960-1317/20/7/075040 |
0.617 |
|
2010 |
Basu AS, Gianchandani YB. Microfluidic doublets in aqueous samples generated by microfabricated thermal probes Sensors and Actuators a: Physical. 158: 116-120. DOI: 10.1016/J.Sna.2009.12.003 |
0.715 |
|
2010 |
Evans AT, Chiravuri S, Gianchandani YB. Erratum to: Transdermal power transfer for recharging implanted drug delivery devices via the refill port Biomedical Microdevices. 12: 361-361. DOI: 10.1007/S10544-010-9397-2 |
0.308 |
|
2009 |
Li T, Barnett A, Rogers KL, Gianchandani YB. A blood sampling microsystem for pharmacokinetic applications: design, fabrication, and initial results. Lab On a Chip. 9: 3495-503. PMID 20024028 DOI: 10.1039/B910508E |
0.312 |
|
2009 |
Basu AS, Gianchandani YB. Nanopatterning: Surfaces feel the heat. Nature Nanotechnology. 4: 622-3. PMID 19809448 DOI: 10.1038/Nnano.2009.287 |
0.668 |
|
2009 |
Gianchandani YB, Wright SA, Eun CK, Wilson CG, Mitra B. Exploring microdischarges for portable sensing applications. Analytical and Bioanalytical Chemistry. 395: 559-75. PMID 19672581 DOI: 10.1007/S00216-009-3011-6 |
0.791 |
|
2009 |
Basu AS, Gianchandani YB. A Programmable Array for Contact-Free Manipulation of Floating Droplets on Featureless Substrates by the Modulation of Surface Tension Ieee\/Asme Journal of Microelectromechanical Systems. 18: 1163-1172. DOI: 10.1109/Jmems.2009.2029961 |
0.703 |
|
2009 |
Park JM, Evans AT, Rasmussen K, Brosten TR, Nellis GF, Klein SA, Gianchandani YB. A microvalve with integrated sensors and customizable normal state for low-temperature operation Journal of Microelectromechanical Systems. 18: 868-877. DOI: 10.1109/Jmems.2009.2021097 |
0.36 |
|
2009 |
Wright SA, Gianchandani YB. Discharge-based pressure sensors for high-temperature applications using three-dimensional and planar microstructures Journal of Microelectromechanical Systems. 18: 736-743. DOI: 10.1109/Jmems.2009.2017110 |
0.409 |
|
2009 |
Green SR, Gianchandani YB. Wireless magnetoelastic monitoring of biliary stents Journal of Microelectromechanical Systems. 18: 64-78. DOI: 10.1109/Jmems.2008.2008568 |
0.625 |
|
2008 |
Takahata K, Gianchandani YB. A Micromachined Capacitive Pressure Sensor Using a Cavity-Less Structure with Bulk-Metal/Elastomer Layers and Its Wireless Telemetry Application. Sensors (Basel, Switzerland). 8: 2317-2330. PMID 27879824 DOI: 10.3390/S8042317 |
0.684 |
|
2008 |
Mitra B, Levey B, Gianchandani YB. Hybrid Arc/Glow Microdischarges at Atmospheric Pressure and Their Use in Portable Systems for Liquid and Gas Sensing Ieee Transactions On Plasma Science. 36: 1913-1924. DOI: 10.1109/Tps.2008.927135 |
0.723 |
|
2008 |
Mitra B, Gianchandani YB. The detection of chemical vapors in air using optical emission spectroscopy of pulsed microdischarges from two- and three-electrode microstructures Ieee Sensors Journal. 8: 1445-1454. DOI: 10.1109/Jsen.2008.920720 |
0.705 |
|
2008 |
Eun CK, Wilson C, Gianchandani YB. A bulk silicon micromachined structure for gas microdischarge-based detection of beta-particles Journal of Micromechanics and Microengineering. 18: 095007. DOI: 10.1088/0960-1317/18/9/095007 |
0.731 |
|
2008 |
Basu AS, Gianchandani YB. Virtual microfluidic traps, filters, channels and pumps using Marangoni flows Journal of Micromechanics and Microengineering. 18: 115031. DOI: 10.1088/0960-1317/18/11/115031 |
0.718 |
|
2008 |
Park JM, Taylor RP, Evans AT, Brosten TR, Nellis GF, Klein SA, Feller JR, Salerno L, Gianchandani YB. A piezoelectric microvalve for cryogenic applications Journal of Micromechanics and Microengineering. 18. DOI: 10.1088/0960-1317/18/1/015023 |
0.36 |
|
2008 |
Gupta NK, Gianchandani YB. Thermal transpiration in zeolites: A mechanism for motionless gas pumps Applied Physics Letters. 93: 193511. DOI: 10.1063/1.3025304 |
0.573 |
|
2007 |
Li T, Gianchandani RY, Gianchandani YB. Micromachined bulk PZT tissue contrast sensor for fine needle aspiration biopsy. Lab On a Chip. 7: 179-85. PMID 17268619 DOI: 10.1039/B611233A |
0.34 |
|
2007 |
Kashani A, Maddocks JR, Nellis GF, Gianchandani YB. Technologies for cooling of large distributed and deployable loads Proceedings of Spie - the International Society For Optical Engineering. 6678. DOI: 10.1117/12.734351 |
0.345 |
|
2007 |
Wright SA, Gianchandani YB. Controlling pressure in microsystem packages by on-chip microdischarges between thin-film titanium electrodes Journal of Vacuum Science and Technology B: Microelectronics and Nanometer Structures. 25: 1711-1720. DOI: 10.1116/1.2782510 |
0.371 |
|
2007 |
Wilson CG, Gianchandani YB. Selective deposition of silicon at room temperature using DC microplasmas Ieee Transactions On Plasma Science. 35: 573-577. DOI: 10.1109/Tps.2007.897412 |
0.347 |
|
2007 |
Basu AS, Gianchandani YB. Shaping high-speed Marangoni flow in liquid films by microscale perturbations in surface temperature Applied Physics Letters. 90: 034102. DOI: 10.1063/1.2430777 |
0.695 |
|
2007 |
Brosten TR, Park JM, Evans AT, Rasmussen K, Nellis GF, Klein SA, Feller JR, Salerno L, Gianchandani YB. A numerical flow model and experimental results of a cryogenic micro-valve for distributed cooling applications Cryogenics. 47: 501-509. DOI: 10.1016/J.Cryogenics.2007.06.002 |
0.315 |
|
2006 |
Gaitas A, Gianchandani YB. An experimental study of the contact mode AFM scanning capability of polyimide cantilever probes. Ultramicroscopy. 106: 874-80. PMID 16707224 DOI: 10.1016/J.Ultramic.2005.12.021 |
0.323 |
|
2006 |
Mitra B, Wilson CG, Que L, Selvaganapathy P, Gianchandani YB. Microfluidic discharge-based optical sources for detection of biochemicals. Lab On a Chip. 6: 60-5. PMID 16372070 DOI: 10.1039/B510332K |
0.669 |
|
2006 |
Gupta NK, Gianchandani YB. Modeling and simulation of a surface micromachined knudsen pump American Society of Mechanical Engineers, Micro-Electro Mechanical Systems Division, (Publications) Mems. DOI: 10.1115/IMECE2006-14940 |
0.518 |
|
2006 |
Takahata K, Gianchandani YB, Wise KD. Micromachined antenna stents and cuffs for monitoring intraluminal pressure and flow Journal of Microelectromechanical Systems. 15: 1289-1298. DOI: 10.1109/Jmems.2006.880229 |
0.722 |
|
2006 |
Chu LL, Que L, Oliver AD, Gianchandani YB. Lifetime studies of electrothermal bent-beam actuators in single-crystal silicon and polysilicon Ieee\/Asme Journal of Microelectromechanical Systems. 15: 498-506. DOI: 10.1109/Jmems.2006.876780 |
0.365 |
|
2006 |
Li T, Gianchandani YB. A micromachining process for die-scale pattern transfer in ceramics and its application to bulk piezoelectric actuators Ieee\/Asme Journal of Microelectromechanical Systems. 15: 605-612. DOI: 10.1109/Jmems.2006.876667 |
0.337 |
|
2006 |
Shimamura Y, Udeshi K, Que L, Park J, Gianchandani YB. Impact behavior and energy transfer efficiency of pulse-driven bent-beam electrothermal actuators Ieee\/Asme Journal of Microelectromechanical Systems. 15: 101-110. DOI: 10.1109/Jmems.2005.863696 |
0.765 |
|
2006 |
Udeshi K, Liao K, Que L, Gianchandani YB, Galvanauskas A. Programmable optical wave form shaper on a microchip Applied Physics Letters. 89: 031120. DOI: 10.1063/1.2222247 |
0.764 |
|
2006 |
Taylor RP, Nellis GF, Klein SA, Hoch DW, Fellers J, Roach P, Park JM, Gianchandani Y. Measurements of the material properties of a laminated piezoelectric stack at cryogenic temperatures Aip Conference Proceedings. 824: 200-207. DOI: 10.1063/1.2192352 |
0.357 |
|
2005 |
Liao K, Udeshi K, Que L, Gianchandani YB, Galvanauskes A. Monolithic fiber-grating and MEMS based devices for controllable ultrafast pulse shaping Proceedings of Spie. 5709: 13-17. DOI: 10.1117/12.602038 |
0.763 |
|
2005 |
McNamara S, Gianchandani YB. On-chip vacuum generated by a micromachined Knudsen pump Ieee\/Asme Journal of Microelectromechanical Systems. 14: 741-746. DOI: 10.1109/Jmems.2005.850718 |
0.427 |
|
2005 |
Chu LL, Takahata K, Selvaganapathy PR, Gianchandani YB, Shohet JL. A micromachined Kelvin probe with integrated actuator for microfluidic and solid-state applications Journal of Microelectromechanical Systems. 14: 691-698. DOI: 10.1109/Jmems.2005.845453 |
0.668 |
|
2005 |
Que L, Wilson C, Gianchandani Y. Microfluidic electrodischarge devices with integrated dispersion optics for spectral analysis of water impurities Journal of Microelectromechanical Systems. 14: 185-191. DOI: 10.1109/Jmems.2004.839337 |
0.358 |
|
2005 |
Lee J, Gianchandani YB. A temperature-dithering closed-loop interface circuit for a scanning thermal microscopy system Ieee\/Asme Journal of Microelectromechanical Systems. 14: 44-53. DOI: 10.1109/Jmems.2004.839011 |
0.355 |
|
2004 |
Basu AS, McNamara S, Gianchandani YB. Scanning thermal lithography: Maskless, submicron thermochemical patterning of photoresist by ultracompliant probes Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures. 22: 3217. DOI: 10.1116/1.1808732 |
0.708 |
|
2004 |
Takahata K, Gianchandani YB. A planar approach for manufacturing cardiac stents: design, fabrication, and mechanical evaluation Ieee\/Asme Journal of Microelectromechanical Systems. 13: 933-939. DOI: 10.1109/Jmems.2004.838357 |
0.628 |
|
2004 |
McNamara S, Basu AS, Lee J, Gianchandani YB. Ultracompliant thermal probe array for scanning non-planar surfaces without force feedback Journal of Micromechanics and Microengineering. 15: 237-243. DOI: 10.1088/0960-1317/15/1/033 |
0.719 |
|
2004 |
Lee J-, Gianchandani YB. High-resolution scanning thermal probe with servocontrolled interface circuit for microcalorimetry and other applications Review of Scientific Instruments. 75: 1222-1227. DOI: 10.1063/1.1711153 |
0.353 |
|
2004 |
McNamara S, Gianchandani YB. LIGA fabricated 19-element threshold accelerometer array Sensors and Actuators a: Physical. 112: 175-183. DOI: 10.1016/J.Sna.2003.10.064 |
0.333 |
|
2003 |
Luo Q, Mutlu S, Gianchandani YB, Svec F, Fréchet JM. Monolithic valves for microfluidic chips based on thermoresponsive polymer gels. Electrophoresis. 24: 3694-702. PMID 14613195 DOI: 10.1002/Elps.200305577 |
0.702 |
|
2003 |
Thompson K, Booske JH, Cooper RF, Gianchandani YB. Electromagnetic fast firing for ultrashallow junction formation Ieee Transactions On Semiconductor Manufacturing. 16: 460-468. DOI: 10.1109/Tsm.2003.815198 |
0.345 |
|
2003 |
Oliver AD, Vigil SR, Gianchandani YB. Photothermal surface-micromachined actuators Ieee Transactions On Electron Devices. 50: 1156-1157. DOI: 10.1109/Ted.2003.812505 |
0.346 |
|
2003 |
Wilson CG, Gianchandani YB, Wendt AE. High-voltage constraints for vacuum packaged microstructures Journal of Microelectromechanical Systems. 12: 835-839. DOI: 10.1109/Jmems.2003.820278 |
0.353 |
|
2003 |
Park J, Gianchandani YB. A servo-controlled capacitive pressure sensor using a capped-cylinder structure microfabricated by a three-mask process Ieee\/Asme Journal of Microelectromechanical Systems. 12: 209-220. DOI: 10.1109/Jmems.2003.809953 |
0.413 |
|
2003 |
Chu LL, Gianchandani YB. A micromachined 2D positioner with electrothermal actuation and sub-nanometer capacitive sensing Journal of Micromechanics and Microengineering. 13: 279-285. DOI: 10.1088/0960-1317/13/2/316 |
0.385 |
|
2003 |
Wilson CG, Gianchandani YB, Arslanbekov RR, Kolobov V, Wendt AE. Profiling and modeling of dc nitrogen microplasmas Journal of Applied Physics. 94: 2845-2851. DOI: 10.1063/1.1595143 |
0.321 |
|
2003 |
Li M-, Gianchandani YB. Applications of a low contact force polyimide shank bolometer probe for chemical and biological diagnostics Sensors and Actuators a-Physical. 104: 236-245. DOI: 10.1016/S0924-4247(03)00026-8 |
0.341 |
|
2002 |
Wilson CG, Gianchandani YB. Spectral detection of metal contaminants in water using an on-chip microglow discharge Ieee Transactions On Electron Devices. 49: 2317-2322. DOI: 10.1109/Ted.2002.805608 |
0.34 |
|
2002 |
Chu LL, Que L, Gianchandani YB. Measurements of material properties using differential capacitive strain sensors Ieee\/Asme Journal of Microelectromechanical Systems. 11: 489-498. DOI: 10.1109/Jmems.2002.803277 |
0.343 |
|
2002 |
Thompson K, Gianchandani YB, Booske J, Cooper RF. Direct silicon-silicon bonding by electromagnetic induction heating Journal of Microelectromechanical Systems. 11: 285-292. DOI: 10.1109/Jmems.2002.800929 |
0.323 |
|
2002 |
Takahata K, Gianchandani Y. Batch mode micro-electro-discharge machining Journal of Microelectromechanical Systems. 11: 102-110. DOI: 10.1109/84.993444 |
0.65 |
|
2002 |
Thompson K, Booske JH, Gianchandani YB, Cooper RF. Electromagnetic annealing for the 100 nm technology node Ieee Electron Device Letters. 23: 127-129. DOI: 10.1109/55.988813 |
0.331 |
|
2002 |
Chu LL, Hetrick JA, Gianchandani YB. High amplification compliant microtransmissions for rectilinear electrothermal actuators Sensors and Actuators, a: Physical. 97: 776-783. DOI: 10.1016/S0924-4247(02)00020-1 |
0.353 |
|
2001 |
Park J, Chu LL, Oliver AD, Gianchandani YB. Bent-beam electrothermal actuators-Part II: Linear and rotary microengines Ieee\/Asme Journal of Microelectromechanical Systems. 10: 255-262. DOI: 10.1109/84.925774 |
0.316 |
|
2001 |
Que L, Park J, Gianchandani YB. Bent-beam electrothermal actuators-Part I: Single beam and cascaded devices Ieee\/Asme Journal of Microelectromechanical Systems. 10: 247-254. DOI: 10.1109/84.925771 |
0.355 |
|
2001 |
Li M-, Wu JJ, Gianchandani YB. Surface micromachined polyimide scanning thermocouple probes Ieee\/Asme Journal of Microelectromechanical Systems. 10: 3-9. DOI: 10.1109/84.911085 |
0.364 |
|
2000 |
Li M, Gianchandani YB. Microcalorimetry applications of a surface micromachined bolometer-type thermal probe Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures. 18: 3600. DOI: 10.1116/1.1313581 |
0.354 |
|
2000 |
Park JS, Gianchandani YB. A capacitive absolute-pressure sensor with external pick-off electrodes Journal of Micromechanics and Microengineering. 10: 528-533. DOI: 10.1088/0960-1317/10/4/307 |
0.415 |
|
2000 |
Gianchandani YB, Kim H, Shinn M, Ha B, Lee B, Najafi K, Song C. Fabrication process for integrating polysilicon microstructures with post-processed CMOS circuits Journal of Micromechanics and Microengineering. 10: 380-386. DOI: 10.1088/0960-1317/10/3/312 |
0.548 |
|
1998 |
Gianchandani YB, Shinn M, Najafi K. Impact of high-thermal budget anneals on polysilicon as a micromechanical material Journal of Microelectromechanical Systems. 7: 102-105. DOI: 10.1109/84.661391 |
0.531 |
|
1997 |
Gianchandani YB, Shinn M, Najafi K. Impact of long, high temperature anneals on residual stress in polysilicon Sensors. 1: 623-624. DOI: 10.1109/Sensor.1997.613728 |
0.501 |
|
1997 |
Gianchandani Y, Najafi K. A silicon micromachined scanning thermal profiler with integrated elements for sensing and actuation Ieee Transactions On Electron Devices. 44: 1857-1868. DOI: 10.1109/16.641353 |
0.584 |
|
1996 |
Gianchandani Y, Najafi K. Bent-beam strain sensors Journal of Microelectromechanical Systems. 5: 52-58. DOI: 10.1109/84.485216 |
0.531 |
|
1992 |
Gianchandani Y, Najafi K. A bulk silicon dissolved wafer process for microelectromechanical devices Journal of Microelectromechanical Systems. 1: 77-85. DOI: 10.1109/84.157361 |
0.561 |
|
1992 |
Gianchandani Y, Najafi K. Batch-assembled multi-level micromachined mechanisms from bulk silicon Journal of Micromechanics and Microengineering. 2: 80-85. DOI: 10.1088/0960-1317/2/2/003 |
0.552 |
|
Show low-probability matches. |