Diego Hernando, Ph.D. - Publications

Affiliations: 
2010 University of Illinois, Urbana-Champaign, Urbana-Champaign, IL 
Area:
Electronics and Electrical Engineering, Biomedical Engineering

93 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2021 Hu HH, Yokoo T, Bashir MR, Sirlin CB, Hernando D, Malyarenko D, Chenevert TL, Smith MA, Serai SD, Middleton MS, Henderson WC, Hamilton G, Shaffer J, Shu Y, Tkach JA, et al. Linearity and Bias of Proton Density Fat Fraction as a Quantitative Imaging Biomarker: A Multicenter, Multiplatform, Multivendor Phantom Study. Radiology. 202912. PMID 33464181 DOI: 10.1148/radiol.2021202912  0.302
2020 Hernando D, Cook RJ, Qazi N, Longhurst CA, Diamond CA, Reeder SB. Complex confounder-corrected R2* mapping for liver iron quantification with MRI. European Radiology. PMID 32785766 DOI: 10.1007/S00330-020-07123-X  0.319
2020 Zhao R, Hamilton G, Brittain JH, Reeder SB, Hernando D. Design and evaluation of quantitative MRI phantoms to mimic the simultaneous presence of fat, iron, and fibrosis in the liver. Magnetic Resonance in Medicine. PMID 32783200 DOI: 10.1002/Mrm.28452  0.345
2020 Luo H, Zhu A, Wiens CN, Starekova J, Shimakawa A, Reeder SB, Johnson KM, Hernando D. Free-breathing liver fat and quantification using motion-corrected averaging based on a nonlocal means algorithm. Magnetic Resonance in Medicine. PMID 32738089 DOI: 10.1002/Mrm.28439  0.357
2020 Zhao R, Zhang Y, Wang X, Colgan TJ, Rehm JL, Reeder SB, Johnson KM, Hernando D. Motion-robust, high-SNR liver fat quantification using a 2D sequential acquisition with a variable flip angle approach. Magnetic Resonance in Medicine. PMID 32243665 DOI: 10.1002/Mrm.28263  0.375
2020 Zhang Y, Wells SA, Triche BL, Kelcz F, Hernando D. Stimulated-echo diffusion-weighted imaging with moderate b values for the detection of prostate cancer. European Radiology. PMID 32064561 DOI: 10.1007/S00330-020-06689-W  0.349
2019 Wang X, Hernando D, Reeder SB. Phase-based T mapping with gradient echo imaging. Magnetic Resonance in Medicine. PMID 31872470 DOI: 10.1002/Mrm.28138  0.342
2019 Hu HH, Branca RT, Hernando D, Karampinos DC, Machann J, McKenzie CA, Wu HH, Yokoo T, Velan SS. Magnetic resonance imaging of obesity and metabolic disorders: Summary from the 2019 ISMRM Workshop. Magnetic Resonance in Medicine. PMID 31782551 DOI: 10.1002/Mrm.28103  0.36
2019 Wang X, Colgan TJ, Hinshaw LA, Roberts NT, Bancroft LCH, Hamilton G, Hernando D, Reeder SB. T -corrected quantitative chemical shift-encoded MRI. Magnetic Resonance in Medicine. PMID 31724776 DOI: 10.1002/Mrm.28062  0.396
2019 Peña-Nogales Ó, Hernando D, Aja-Fernández S, de Luis-Garcia R. Determination of optimized set of b-values for Apparent Diffusion Coefficient mapping in liver Diffusion-Weighted MRI. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 310: 106634. PMID 31710951 DOI: 10.1016/J.Jmr.2019.106634  0.326
2019 Nguyen SM, Wiepz GJ, Schotzko M, Simmons HA, Mejia A, Ludwig KD, Zhu A, Brunner K, Hernando D, Reeder SB, Wieben O, Johnson K, Shah D, Golos TG. Impact of Ferumoxytol Magnetic Resonance Imaging on the Rhesus Macaque Maternal-Fetal Interface. Biology of Reproduction. PMID 31511859 DOI: 10.1093/Biolre/Ioz181  0.315
2019 Liu TT, Rodgers AC, Nicholson TM, Macoska JA, Marker PC, Vezina CM, Bjorling DE, Roldan-Alzate A, Hernando D, Lloyd GL, Hacker TA, Ricke WA. Ultrasonography of the Adult Male Urinary Tract for Urinary Functional Testing. Journal of Visualized Experiments : Jove. PMID 31475976 DOI: 10.3791/59802  0.327
2019 Zhu A, Hernando D, Johnson KM, Reeder SB. Characterizing a short T * signal component in the liver using ultrashort TE chemical shift-encoded MRI at 1.5T and 3.0T. Magnetic Resonance in Medicine. PMID 31270858 DOI: 10.1002/Mrm.27876  0.34
2019 Pooler BD, Hernando D, Reeder SB. Clinical Implementation of a Focused MRI Protocol for Hepatic Fat and Iron Quantification. Ajr. American Journal of Roentgenology. 1-6. PMID 30917020 DOI: 10.2214/Ajr.18.20947  0.313
2019 Zhang Y, Peña-Nogales Ó, Holmes JH, Hernando D. Motion-robust and blood-suppressed M1-optimized diffusion MR imaging of the liver. Magnetic Resonance in Medicine. PMID 30859628 DOI: 10.1002/Mrm.27735  0.32
2019 Yi SY, Barnett BR, Torres-Velázquez M, Zhang Y, Hurley SA, Rowley PA, Hernando D, Yu JJ. Detecting Microglial Density With Quantitative Multi-Compartment Diffusion MRI. Frontiers in Neuroscience. 13: 81. PMID 30837826 DOI: 10.3389/Fnins.2019.00081  0.356
2018 Stojanovska J, Lumeng CN, Griffin C, Hernando D, Hoffmann U, Haft JW, Kim KM, Burant CF, Singer K, Tsodikov A, Long BD, Romano MA, Tang PC, Yang B, Chenevert TL. Water-fat magnetic resonance imaging quantifies relative proportions of brown and white adipose tissues: experiments. Journal of Medical Imaging (Bellingham, Wash.). 5: 024007. PMID 30137870 DOI: 10.1117/1.Jmi.5.2.024007  0.392
2018 Pickhardt PJ, Graffy PM, Reeder SB, Hernando D, Li K. Quantification of Liver Fat Content With Unenhanced MDCT: Phantom and Clinical Correlation With MRI Proton Density Fat Fraction. Ajr. American Journal of Roentgenology. W1-W7. PMID 30016142 DOI: 10.2214/Ajr.17.19391  0.341
2018 Pirasteh A, Yuan Q, Hernando D, Reeder SB, Pedrosa I, Yokoo T. Inter-method reproducibility of biexponential R MR relaxometry for estimation of liver iron concentration. Magnetic Resonance in Medicine. PMID 29770484 DOI: 10.1002/Mrm.27348  0.309
2018 Park CC, Hooker C, Hooker JC, Bass E, Haufe W, Schlein A, Covarrubias Y, Heba E, Bydder M, Wolfson T, Gamst A, Loomba R, Schwimmer J, Hernando D, Reeder SB, et al. Assessment of a high-SNR chemical-shift-encoded MRI with complex reconstruction for proton density fat fraction (PDFF) estimation overall and in the low-fat range. Journal of Magnetic Resonance Imaging : Jmri. PMID 29707848 DOI: 10.1002/Jmri.26168  0.411
2018 Zhang Y, Holmes J, Rabanillo I, Guidon A, Wells S, Hernando D. Quantitative diffusion MRI using reduced field-of-view and multi-shot acquisition techniques: Validation in phantoms and prostate imaging. Magnetic Resonance Imaging. PMID 29678540 DOI: 10.1016/J.Mri.2018.04.006  0.35
2018 Pooler BD, Hernando D, Ruby JA, Ishii H, Shimakawa A, Reeder SB. Validation of a motion-robust 2D sequential technique for quantification of hepatic proton density fat fraction during free breathing. Journal of Magnetic Resonance Imaging : Jmri. PMID 29665193 DOI: 10.1002/Jmri.26056  0.31
2018 Roberts NT, Hernando D, Holmes JH, Wiens CN, Reeder SB. Noise properties of proton density fat fraction estimated using chemical shift-encoded MRI. Magnetic Resonance in Medicine. PMID 29322549 DOI: 10.1002/Mrm.27065  0.356
2017 Rabanillo I, Aja-Fernandez S, Alberola-Lopez C, Hernando D. Exact Calculation of Noise Maps and g-Factor in GRAPPA using a k-space Analysis. Ieee Transactions On Medical Imaging. PMID 28991737 DOI: 10.1109/Tmi.2017.2760921  0.379
2017 Yokoo T, Serai SD, Pirasteh A, Bashir MR, Hamilton G, Hernando D, Hu HH, Hetterich H, Kühn JP, Kukuk GM, Loomba R, Middleton MS, Obuchowski NA, Song JS, Tang A, et al. Linearity, Bias, and Precision of Hepatic Proton Density Fat Fraction Measurements by Using MR Imaging: A Meta-Analysis. Radiology. 170550. PMID 28892458 DOI: 10.1148/Radiol.2017170550  0.436
2017 van Heeswijk RB, Colotti R, Darçot E, Delacoste J, Pellegrin M, Piccini D, Hernando D. Chemical shift encoding (CSE) for sensitive fluorine-19 MRI of perfluorocarbons with complex spectra. Magnetic Resonance in Medicine. PMID 28862351 DOI: 10.1002/Mrm.26895  0.333
2017 Ludwig KD, Hernando D, Roberts NT, van Heeswijk RB, Fain SB. A chemical shift encoding (CSE) approach for spectral selection in fluorine-19 MRI. Magnetic Resonance in Medicine. PMID 28833448 DOI: 10.1002/Mrm.26874  0.303
2017 Campo CA, Hernando D, Schubert T, Bookwalter CA, Pay AJV, Reeder SB. Standardized Approach for ROI-Based Measurements of Proton Density Fat Fraction and R2* in the Liver. Ajr. American Journal of Roentgenology. 1-12. PMID 28705058 DOI: 10.2214/Ajr.17.17812  0.357
2017 Kühn JP, Meffert P, Heske C, Kromrey ML, Schmidt CO, Mensel B, Völzke H, Lerch MM, Hernando D, Mayerle J, Reeder SB. Prevalence of Fatty Liver Disease and Hepatic Iron Overload in a Northeastern German Population by Using Quantitative MR Imaging. Radiology. PMID 28481195 DOI: 10.1148/Radiol.2017161228  0.312
2017 Wang X, Reeder SB, Hernando D. An acetone-based phantom for quantitative diffusion MRI. Journal of Magnetic Resonance Imaging : Jmri. PMID 28432796 DOI: 10.1002/Jmri.25727  0.355
2017 Haufe WM, Wolfson T, Hooker CA, Hooker JC, Covarrubias Y, Schlein AN, Hamilton G, Middleton MS, Angeles JE, Hernando D, Reeder SB, Schwimmer JB, Sirlin CB. Accuracy of PDFF estimation by magnitude-based and complex-based MRI in children with MR spectroscopy as a reference. Journal of Magnetic Resonance Imaging : Jmri. PMID 28323377 DOI: 10.1002/Jmri.25699  0.382
2017 Motosugi U, Hernando D, Wiens C, Bannas P, Reeder SB. High SNR Acquisitions Improve the Repeatability of Liver Fat Quantification Using Confounder-corrected Chemical Shift-encoded MR Imaging. Magnetic Resonance in Medical Sciences : Mrms : An Official Journal of Japan Society of Magnetic Resonance in Medicine. PMID 28190853 DOI: 10.2463/Mrms.Mp.2016-0081  0.469
2016 Kramer H, Pickhardt PJ, Kliewer MA, Hernando D, Chen GH, Zagzebski JA, Reeder SB. Accuracy of Liver Fat Quantification With Advanced CT, MRI, and Ultrasound Techniques: Prospective Comparison With MR Spectroscopy. Ajr. American Journal of Roentgenology. 1-9. PMID 27726414 DOI: 10.2214/Ajr.16.16565  0.345
2016 Kasza I, Hernando D, Roldán-Alzate A, Alexander CM, Reeder SB. Thermogenic profiling using magnetic resonance imaging of dermal and other adipose tissues. Jci Insight. 1: e87146. PMID 27668285 DOI: 10.1172/Jci.Insight.87146  0.372
2016 Colgan TJ, Hernando D, Sharma SD, Reeder SB. The effects of concomitant gradients on chemical shift encoded MRI. Magnetic Resonance in Medicine. PMID 27650137 DOI: 10.1002/Mrm.26461  0.357
2016 Horng DE, Hernando D, Reeder SB. Quantification of liver fat in the presence of iron overload. Journal of Magnetic Resonance Imaging : Jmri. PMID 27405703 DOI: 10.1002/Jmri.25382  0.405
2016 Mahlke C, Hernando D, Jahn C, Cigliano A, Ittermann T, Mössler A, Kromrey ML, Domaska G, Reeder SB, Kühn JP. Quantification of liver proton-density fat fraction in 7.1T preclinical MR systems: Impact of the fitting technique. Journal of Magnetic Resonance Imaging : Jmri. PMID 27197806 DOI: 10.1002/Jmri.25319  0.414
2016 Hernando D, Sharma SD, Aliyari Ghasabeh M, Alvis BD, Arora SS, Hamilton G, Pan L, Shaffer JM, Sofue K, Szeverenyi NM, Welch EB, Yuan Q, Bashir MR, Kamel IR, Rice MJ, et al. Multisite, multivendor validation of the accuracy and reproducibility of proton-density fat-fraction quantification at 1.5T and 3T using a fat-water phantom. Magnetic Resonance in Medicine. PMID 27080068 DOI: 10.1002/Mrm.26228  0.372
2015 Bannas P, Kramer H, Hernando D, Agni R, Cunningham AM, Mandal R, Motosugi U, Sharma SD, Munoz Del Rio A, Fernandez L, Reeder SB. Quantitative MR Imaging of Hepatic Steatosis: Validation in Ex Vivo Human Livers. Hepatology (Baltimore, Md.). PMID 26224591 DOI: 10.1002/Hep.28012  0.402
2015 Motosugi U, Bannas P, Hernando D, Salmani Rahimi M, Holmes JH, Reeder SB. Intraindividual Crossover Comparison of Gadoxetic Acid Dose for Liver MRI in Normal Volunteers. Magnetic Resonance in Medical Sciences : Mrms : An Official Journal of Japan Society of Magnetic Resonance in Medicine. PMID 26104082 DOI: 10.2463/Mrms.2015-0005  0.358
2015 Attenberger UI, Morelli J, Budjan J, Henzler T, Sourbron S, Bock M, Riffel P, Hernando D, Ong MM, Schoenberg SO. Fifty Years of Technological Innovation: Potential and Limitations of Current Technologies in Abdominal Magnetic Resonance Imaging and Computed Tomography. Investigative Radiology. 50: 584-93. PMID 26039773 DOI: 10.1097/Rli.0000000000000173  0.383
2015 Reeder SB, Smith MR, Hernando D. Mathematical optimization of contrast concentration for t1 -weighted spoiled gradient echo imaging. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. PMID 25981460 DOI: 10.1002/Mrm.25744  0.328
2015 Henze Bancroft LC, Strigel RM, Hernando D, Johnson KM, Kelcz F, Kijowski R, Block WF. Utilization of a balanced steady state free precession signal model for improved fat/water decomposition. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. PMID 25946145 DOI: 10.1002/Mrm.25728  0.389
2015 Rehm JL, Wolfgram PM, Hernando D, Eickhoff JC, Allen DB, Reeder SB. Proton density fat-fraction is an accurate biomarker of hepatic steatosis in adolescent girls and young women. European Radiology. PMID 25916386 DOI: 10.1007/S00330-015-3724-1  0.39
2015 Wang X, Hernando D, Reeder SB. Sensitivity of chemical shift-encoded fat quantification to calibration of fat MR spectrum. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. PMID 25845713 DOI: 10.1002/Mrm.25681  0.381
2015 Motosugi U, Hernando D, Bannas P, Holmes JH, Wang K, Shimakawa A, Iwadate Y, Taviani V, Rehm JL, Reeder SB. Quantification of liver fat with respiratory-gated quantitative chemical shift encoded MRI. Journal of Magnetic Resonance Imaging : Jmri. PMID 25828696 DOI: 10.1002/Jmri.24896  0.405
2015 Bannas P, Motosugi U, Hernando D, Rahimi MS, Holmes JH, Reeder SB. Combined gadoxetic acid and gadofosveset enhanced liver MRI: A feasibility and parameter optimization study. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. PMID 25648403 DOI: 10.1002/Mrm.25554  0.316
2015 Hernando D, Wells SA, Vigen KK, Reeder SB. Effect of hepatocyte-specific gadolinium-based contrast agents on hepatic fat-fraction and R2(⁎). Magnetic Resonance Imaging. 33: 43-50. PMID 25305414 DOI: 10.1016/J.Mri.2014.10.001  0.346
2015 Sharma SD, Hernando D, Horng DE, Reeder SB. Quantitative susceptibility mapping in the abdomen as an imaging biomarker of hepatic iron overload. Magnetic Resonance in Medicine. 74: 673-83. PMID 25199788 DOI: 10.1002/Mrm.25448  0.337
2015 Sharma SD, Artz NS, Hernando D, Horng DE, Reeder SB. Improving chemical shift encoded water-fat separation using object-based information of the magnetic field inhomogeneity. Magnetic Resonance in Medicine. 73: 597-604. PMID 24585487 DOI: 10.1002/Mrm.25163  0.341
2014 Bannas P, Motosugi U, Ichikawa S, Hernando D, Reeder SB. Primer on magnetic resonance imaging of the liver. Clinical Liver Disease. 4: 120-123. PMID 30992937 DOI: 10.1002/Cld.440  0.376
2014 Smith MR, Artz NS, Wiens C, Hernando D, Reeder SB. Characterizing the limits of MRI near metallic prostheses. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. PMID 25483410 DOI: 10.1002/Mrm.25540  0.311
2014 Hernando D, Levin YS, Sirlin CB, Reeder SB. Quantification of liver iron with MRI: state of the art and remaining challenges. Journal of Magnetic Resonance Imaging : Jmri. 40: 1003-21. PMID 24585403 DOI: 10.1002/Jmri.24584  0.316
2014 Kühn JP, Jahn C, Hernando D, Siegmund W, Hadlich S, Mayerle J, Pfannmöller J, Langner S, Reeder S. T1 bias in chemical shift-encoded liver fat-fraction: role of the flip angle. Journal of Magnetic Resonance Imaging : Jmri. 40: 875-83. PMID 24243439 DOI: 10.1002/Jmri.24457  0.391
2014 Kühn JP, Holmes JH, Brau AC, Iwadate Y, Hernando D, Reeder SB. Navigator flip angle optimization for free-breathing T1-weighted hepatobiliary phase imaging with gadoxetic acid. Journal of Magnetic Resonance Imaging : Jmri. 40: 1129-36. PMID 24214890 DOI: 10.1002/Jmri.24480  0.353
2014 Taviani V, Hernando D, Francois CJ, Shimakawa A, Vigen KK, Nagle SK, Schiebler ML, Grist TM, Reeder SB. Whole-heart chemical shift encoded water-fat MRI. Magnetic Resonance in Medicine. 72: 718-25. PMID 24186810 DOI: 10.1002/Mrm.24982  0.382
2014 Kühn JP, Hernando D, Mensel B, Krüger PC, Ittermann T, Mayerle J, Hosten N, Reeder SB. Quantitative chemical shift-encoded MRI is an accurate method to quantify hepatic steatosis. Journal of Magnetic Resonance Imaging : Jmri. 39: 1494-501. PMID 24123655 DOI: 10.1002/Jmri.24289  0.438
2014 Artz NS, Hernando D, Taviani V, Samsonov A, Brittain JH, Reeder SB. Spectrally resolved fully phase-encoded three-dimensional fast spin-echo imaging. Magnetic Resonance in Medicine. 71: 681-90. PMID 23483631 DOI: 10.1002/Mrm.24704  0.324
2013 Kühn JP, Hernando D, Meffert PJ, Reeder S, Hosten N, Laqua R, Steveling A, Ender S, Schröder H, Pillich DT. Proton-density fat fraction and simultaneous R2* estimation as an MRI tool for assessment of osteoporosis. European Radiology. 23: 3432-9. PMID 23812246 DOI: 10.1007/S00330-013-2950-7  0.348
2013 Hernando D, Cook RJ, Diamond C, Reeder SB. Magnetic susceptibility as a B0 field strength independent MRI biomarker of liver iron overload. Magnetic Resonance in Medicine. 70: 648-56. PMID 23801540 DOI: 10.1002/Mrm.24848  0.327
2013 Hernando D, Kramer JH, Reeder SB. Multipeak fat-corrected complex R2* relaxometry: theory, optimization, and clinical validation. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 70: 1319-31. PMID 23359327 DOI: 10.1002/Mrm.24593  0.35
2013 Horng DE, Hernando D, Hines CD, Reeder SB. Comparison of R2* correction methods for accurate fat quantification in fatty liver. Journal of Magnetic Resonance Imaging : Jmri. 37: 414-22. PMID 23165934 DOI: 10.1002/Jmri.23835  0.366
2013 Hansmann J, Hernando D, Reeder SB. Fat confounds the observed apparent diffusion coefficient in patients with hepatic steatosis. Magnetic Resonance in Medicine. 69: 545-52. PMID 23161434 DOI: 10.1002/Mrm.24535  0.408
2013 Bülow R, Mensel B, Meffert P, Hernando D, Evert M, Kühn JP. Diffusion-weighted magnetic resonance imaging for staging liver fibrosis is less reliable in the presence of fat and iron. European Radiology. 23: 1281-7. PMID 23138385 DOI: 10.1007/S00330-012-2700-2  0.386
2013 Hernando D, Kühn JP, Mensel B, Völzke H, Puls R, Hosten N, Reeder SB. R2* estimation using "in-phase" echoes in the presence of fat: the effects of complex spectrum of fat. Journal of Magnetic Resonance Imaging : Jmri. 37: 717-26. PMID 23055408 DOI: 10.1002/Jmri.23851  0.382
2013 Poonawalla AH, Sjoberg BP, Rehm JL, Hernando D, Hines CD, Irarrazaval P, Reeder SB. Adipose tissue MRI for quantitative measurement of central obesity. Journal of Magnetic Resonance Imaging : Jmri. 37: 707-16. PMID 23055365 DOI: 10.1002/Jmri.23846  0.352
2013 Haldar JP, Hernando D, Liang Z. Correction to "Compressed-sensing MRI with random encoding" Ieee Transactions On Medical Imaging. 32: 1362-1362. DOI: 10.1109/Tmi.2013.2270927  0.649
2012 Kühn JP, Hernando D, Muñoz del Rio A, Evert M, Kannengiesser S, Völzke H, Mensel B, Puls R, Hosten N, Reeder SB. Effect of multipeak spectral modeling of fat for liver iron and fat quantification: correlation of biopsy with MR imaging results. Radiology. 265: 133-42. PMID 22923718 DOI: 10.1148/Radiol.12112520  0.378
2012 Hu HH, Börnert P, Hernando D, Kellman P, Ma J, Reeder S, Sirlin C. ISMRM workshop on fat-water separation: insights, applications and progress in MRI. Magnetic Resonance in Medicine. 68: 378-88. PMID 22693111 DOI: 10.1002/Mrm.24369  0.371
2012 Yin X, Guo Y, Li W, Huo E, Zhang Z, Nicolai J, Kleps RA, Hernando D, Katsaggelos AK, Omary RA, Larson AC. Chemical shift MR imaging methods for the quantification of transcatheter lipiodol delivery to the liver: preclinical feasibility studies in a rodent model. Radiology. 263: 714-22. PMID 22623693 DOI: 10.1148/Radiol.12111916  0.442
2012 Hernando D, Vigen KK, Shimakawa A, Reeder SB. R*(2) mapping in the presence of macroscopic B₀ field variations. Magnetic Resonance in Medicine. 68: 830-40. PMID 22161866 DOI: 10.1002/Mrm.23306  0.371
2012 Hines CD, Agni R, Roen C, Rowland I, Hernando D, Bultman E, Horng D, Yu H, Shimakawa A, Brittain JH, Reeder SB. Validation of MRI biomarkers of hepatic steatosis in the presence of iron overload in the ob/ob mouse. Journal of Magnetic Resonance Imaging : Jmri. 35: 844-51. PMID 22127834 DOI: 10.1002/Jmri.22890  0.413
2012 Hernando D, Hines CD, Yu H, Reeder SB. Addressing phase errors in fat-water imaging using a mixed magnitude/complex fitting method. Magnetic Resonance in Medicine. 67: 638-44. PMID 21713978 DOI: 10.1002/Mrm.23044  0.41
2012 Reeder SB, Bice EK, Yu H, Hernando D, Pineda AR. On the performance of T2* correction methods for quantification of hepatic fat content. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 67: 389-404. PMID 21661045 DOI: 10.1002/Mrm.23016  0.371
2011 Van AT, Hernando D, Sutton BP. Motion-induced phase error estimation and correction in 3D diffusion tensor imaging. Ieee Transactions On Medical Imaging. 30: 1933-40. PMID 21652284 DOI: 10.1109/Tmi.2011.2158654  0.365
2011 Hernando D, Karampinos DC, King KF, Haldar JP, Majumdar S, Georgiadis JG, Liang ZP. Removal of olefinic fat chemical shift artifact in diffusion MRI. Magnetic Resonance in Medicine. 65: 692-701. PMID 21337402 DOI: 10.1002/Mrm.22670  0.731
2011 Haldar JP, Hernando D, Liang ZP. Compressed-sensing MRI with random encoding. Ieee Transactions On Medical Imaging. 30: 893-903. PMID 20937579 DOI: 10.1109/Tmi.2010.2085084  0.694
2010 Peng X, Nguyen H, Haldar J, Hernando D, Wang XP, Liang ZP. Correction of field inhomogeneity effects on limited k-space MRSI data using anatomical constraints. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2010: 883-6. PMID 21097201 DOI: 10.1109/IEMBS.2010.5627873  0.673
2010 Hernando D, Liang ZP, Kellman P. Chemical shift-based water/fat separation: a comparison of signal models. Magnetic Resonance in Medicine. 64: 811-22. PMID 20593375 DOI: 10.1002/Mrm.22455  0.564
2010 Kellman P, Hernando D, Arai AE. Myocardial Fat Imaging. Current Cardiovascular Imaging Reports. 3: 83-91. PMID 20401158 DOI: 10.1007/S12410-010-9012-1  0.416
2010 Hernando D, Kellman P, Haldar JP, Liang ZP. Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithm. Magnetic Resonance in Medicine. 63: 79-90. PMID 19859956 DOI: 10.1002/Mrm.22177  0.695
2009 Haldar JP, Hernando D. Rank-Constrained Solutions to Linear Matrix Equations Using PowerFactorization. Ieee Signal Processing Letters. 16: 584-587. PMID 22389578 DOI: 10.1109/Lsp.2009.2018223  0.563
2009 Kellman P, Hernando D, Shah S, Zuehlsdorff S, Jerecic R, Mancini C, Liang ZP, Arai AE. Multiecho dixon fat and water separation method for detecting fibrofatty infiltration in the myocardium. Magnetic Resonance in Medicine. 61: 215-21. PMID 19097213 DOI: 10.1002/Mrm.21657  0.592
2009 Haldar JP, Hernando D, Liang ZP. Super-Resolution reconstruction of mr image sequences with contrast modeling Proceedings - 2009 Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Isbi 2009. 266-269. DOI: 10.1109/ISBI.2009.5193035  0.68
2008 Hernando D, Kellman P, Haldar JP, Liang ZP. A network flow method for improved MR field map estimation in the presence of water and fat. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2008: 82-5. PMID 19162599 DOI: 10.1109/IEMBS.2008.4649096  0.667
2008 Haldar JP, Hernando D, Song SK, Liang ZP. Anatomically constrained reconstruction from noisy data Magnetic Resonance in Medicine. 59: 810-818. PMID 18383297 DOI: 10.1002/Mrm.21536  0.695
2008 Hernando D, Haldar JP, Sutton BP, Ma J, Kellman P, Liang ZP. Joint estimation of water/fat images and field inhomogeneity map. Magnetic Resonance in Medicine. 59: 571-80. PMID 18306409 DOI: 10.1002/Mrm.21522  0.708
2008 Kellman P, Hernando D, Shah S, Zuehlsdorff S, Jerecic R, Liang Z, Arai AE. 1025 Multi-echo dixon fat and water separation method for detecting fibro-fatty infiltration in the myocardium Journal of Cardiovascular Magnetic Resonance. 10: 1-3. DOI: 10.1186/1532-429X-10-S1-A150  0.532
2007 Haldar JP, Hernando D, Budde MD, Wang Q, Song SK, Liang ZP. High-resolution MR metabolic imaging. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2007: 4324-6. PMID 18002959 DOI: 10.1109/IEMBS.2007.4353293  0.69
2007 Haldar JP, Hernando D, Liang ZP. Shaping spatial response functions for optimal estimation of compartmental signals from limited fourier data 2007 4th Ieee International Symposium On Biomedical Imaging: From Nano to Macro - Proceedings. 1364-1367. DOI: 10.1109/ISBI.2007.357114  0.68
2007 Hernando D, Haldar J, Sutton B, Liang ZP. Removal of lipid signal in mrsi using spatial-spectral constraints 2007 4th Ieee International Symposium On Biomedical Imaging: From Nano to Macro - Proceedings. 1360-1363. DOI: 10.1109/ISBI.2007.357113  0.665
2006 Haldar JP, Jacob M, Ebel A, Zhu X, Schuff N, Hernando D, Sutton BP, Liang ZP. Regularized inversion of noisy, incomplete MR spectroscopic imaging data with anatomical prior 2006 3rd Ieee International Symposium On Biomedical Imaging: From Nano to Macro - Proceedings. 2006: 718-721.  0.693
2006 Hernando D, Haldar J, Liang ZP. Reduced-encoding MRI using higher-order generalized series 2006 3rd Ieee International Symposium On Biomedical Imaging: From Nano to Macro - Proceedings. 2006: 29-32.  0.599
Show low-probability matches.