Thomas Rockwell Mackie, PhD - Publications

Affiliations: 
Medical Physics University of Wisconsin, Madison, Madison, WI 
Area:
Biomedical Engineering, Optics Physics

210 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2017 Prajapati S, Cox B, Swader R, Petry G, Eliceiri KW, Jeraj R, Mackie TR. Design of an Open-Source Binary Micromultileaf Collimator for a Small Animal Microradiotherapy System Journal of Medical Devices. 11. DOI: 10.1115/1.4038017  0.312
2017 Walker BJ, Radtke J, Chen G, Eliceiri KW, Mackie TR. A beam optics study of a modular multi-source X-ray tube for novel computed tomography applications Nuclear Instruments & Methods in Physics Research Section a-Accelerators Spectrometers Detectors and Associated Equipment. 868: 1-9. DOI: 10.1016/J.Nima.2017.06.035  0.372
2016 Prajapati S, Mo X, Bednarz B, Lawless M, Hammer C, Flynn R, Westerly D, Jeraj R, Mackie T. SU-F-T-667: Development and Validation of Dose Calculation for An Open-Source KV Treatment Planning System for Small Animal Radiotherapy. Medical Physics. 43: 3617-3618. PMID 28048256 DOI: 10.1118/1.4956853  0.382
2014 Darwish N, Kao C, Thomadsen B, Mackie T. SU-E-J-215: Onboard Split PET Including the Effects of Attenuation, Scatter, and Random Events. Medical Physics. 41: 207. PMID 28037227 DOI: 10.1118/1.4888268  0.562
2014 Bredfeldt JS, Liu Y, Conklin MW, Keely PJ, Mackie TR, Eliceiri KW. Automated quantification of aligned collagen for human breast carcinoma prognosis. Journal of Pathology Informatics. 5: 28. PMID 25250186 DOI: 10.4103/2153-3539.139707  0.617
2014 Bredfeldt JS, Liu Y, Pehlke CA, Conklin MW, Szulczewski JM, Inman DR, Keely PJ, Nowak RD, Mackie TR, Eliceiri KW. Computational segmentation of collagen fibers from second-harmonic generation images of breast cancer. Journal of Biomedical Optics. 19: 16007. PMID 24407500 DOI: 10.1117/1.Jbo.19.1.016007  0.652
2014 Darwish N, Mackie T, Thomadsen B. SU-E-J-174: Adaptive PET-Based Dose Painting with Tomotherapy Medical Physics. 41: 196-197. DOI: 10.1118/1.4888227  0.613
2014 Bredfeldt J, Liu Y, Conklin M, Keely P, Eliceiri K, Mackie T. SU-E-J-107: Supervised Learning Model of Aligned Collagen for Human Breast Carcinoma Prognosis Medical Physics. 41: 180-180. DOI: 10.1118/1.4888159  0.665
2013 Prajapati S, Cox B, Cadman P, Jeraj R, Mackie T. WE-E-108-07: Design of Open-Source Binary Micro MLC for Small Animal Radiotherapy: An OSMD Initiative. Medical Physics. 40: 489. PMID 28518606 DOI: 10.1118/1.4815585  0.339
2013 Bredfeldt J, Liu Y, Wilke L, Keely P, Mackie T, Eliceiri K. MO-D-141-08: Multi-Scale Analysis of Collagen Architecture for Classifying Tumor and Healthy Breast Tissue Images. Medical Physics. 40: 400-401. PMID 28518438 DOI: 10.1118/1.4815255  0.657
2013 Hill P, Westerly D, Mackie T. Fan-beam intensity modulated proton therapy. Medical Physics. 40: 111704. PMID 24320412 DOI: 10.1118/1.4822485  0.59
2013 Westerly DC, Mo X, Tomé WA, Mackie TR, DeLuca PM. A generalized 2D pencil beam scaling algorithm for proton dose calculation in heterogeneous slab geometries. Medical Physics. 40: 061706. PMID 23718585 DOI: 10.1118/1.4804055  0.347
2012 Zhang M, Flynn RT, Mo X, Mackie TR. The energy margin strategy for reducing dose variation due to setup uncertainty in intensity modulated proton therapy (IMPT) delivered with distal edge tracking (DET) Journal of Applied Clinical Medical Physics / American College of Medical Physics. 13: 3863. PMID 22955652  0.324
2012 Sterpin E, MacKie TR, Vynckier S. Monte Carlo computed machine-specific correction factors for reference dosimetry of TomoTherapy static beam for several ion chambers Medical Physics. 39: 4066-4072. PMID 22830739 DOI: 10.1118/1.4722752  0.333
2011 Sterpin E, Chen Y, Chen Q, Lu W, Mackie TR, Vynckier S. Monte Carlo-based simulation of dynamic jaws tomotherapy. Medical Physics. 38: 5230-8. PMID 21978067 DOI: 10.1118/1.3626486  0.485
2011 Sengbusch ER, Mackie TR. Maximum kinetic energy considerations in proton stereotactic radiosurgery. Journal of Applied Clinical Medical Physics / American College of Medical Physics. 12: 3533. PMID 21844866 DOI: 10.1120/Jacmp.V12I3.3533  0.797
2011 Zhang M, Westerly DC, MacKie TR. Introducing an on-line adaptive procedure for prostate image guided intensity modulate proton therapy Physics in Medicine and Biology. 56: 4947-4965. PMID 21772078 DOI: 10.1088/0031-9155/56/15/019  0.392
2011 Vogelius IR, Westerly DC, Aznar MC, Cannon GM, Korreman SS, MacKie TR, Mehta MP, Bentzen SM. Estimated radiation pneumonitis risk after photon versus proton therapy alone or combined with chemotherapy for lung cancer Acta Oncologica. 50: 772-776. PMID 21767173 DOI: 10.3109/0284186X.2011.582519  0.33
2011 Hundertmark B, Sterpin E, Mackie T. A robust procedure for verifying TomoTherapy Hi-Art™ source models for small fields. Physics in Medicine and Biology. 56: 3685-3699. PMID 21617290 DOI: 10.1088/0031-9155/56/12/015  0.331
2011 Sterpin E, Chen Y, Lu W, Mackie TR, Olivera GH, Vynckier S. On the relationships between electron spot size, focal spot size, and virtual source position in Monte Carlo simulations. Medical Physics. 38: 1579-86. PMID 21520869 DOI: 10.1118/1.3556560  0.463
2011 Vogelius IS, Westerly DC, Cannon GM, MacKie TR, Mehta MP, Sugie C, Bentzen SM. Intensity-modulated radiotherapy might increase pneumonitis risk relative to three-dimensional conformal radiotherapy in patients receiving combined chemotherapy and radiotherapy: A modeling study of dose dumping International Journal of Radiation Oncology Biology Physics. 80: 893-899. PMID 21477946 DOI: 10.1016/J.Ijrobp.2010.12.073  0.347
2011 Schubert LK, Gondi V, Sengbusch E, Westerly DC, Soisson ET, Paliwal BR, MacKie TR, Mehta MP, Patel RR, Tomé WA, Cannon GM. Dosimetric comparison of left-sided whole breast irradiation with 3DCRT, forward-planned IMRT, inverse-planned IMRT, helical tomotherapy, and topotherapy Radiotherapy and Oncology. 100: 241-246. PMID 21316783 DOI: 10.1016/J.Radonc.2011.01.004  0.785
2011 Prajapati S, Seaton J, Sekhon J, Mackie T, Jeraj R. TH-C-220-02: Development of Binary Micro MLCs for an Open Source Small Animal Imaging and Therapy System with IMRT Capability Medical Physics. 38: 3862-3862. DOI: 10.1118/1.3613545  0.365
2011 Mo X, Westerly D, Zhang M, Mackie T. TH‐C‐BRB‐07: Treatment Planning with Multiple Spot Sizes to Improve Delivery Efficiency in Intensity Modulated Proton Therapy Medical Physics. 38: 3854-3854. DOI: 10.1118/1.3613512  0.407
2011 Wang D, Mackie T, Tome W. TU-G-BRB-06: Conversion of X-Ray Sinogram to Proton Sinogram to Address the Limited-Range Issue in Proton Computed Tomography Medical Physics. 38: 3779-3780. DOI: 10.1118/1.3613226  0.303
2011 Darwish N, Mackie T, Kao C, Thomadsen B. TU-C-214-12: On-Board PET with Tomotherapy Using Open Dual Ring Geometry with Consideration to DOI Effect Medical Physics. 38: 3758-3758. DOI: 10.1118/1.3613144  0.577
2011 Sengbusch E, Mackie T. MO-D-BRB-02: Maximum Kinetic Energy Considerations in Coplanar Arc-Based Proton Stereotactic Radiosurgery Medical Physics. 38: 3709-3709. DOI: 10.1118/1.3612907  0.796
2011 Das I, Mackie T. MO‐B‐BRA‐01: Dosimetry of Small Fields Medical Physics. 38: 3707-3708. DOI: 10.1118/1.3612899  0.359
2011 Kissick M, Flynn R, Mackie T, Mo X, Zhao D, Campos D, Yan Y. SU-E-T-841: The Potential of Probablistic Optimization for Tumor Motion with IMRT Medical Physics. 38: 3684-3685. DOI: 10.1118/1.3612805  0.332
2011 Sterpin E, Orban J, Geets X, Goossens S, Wanet M, Mackie T, Vynckier S, Gregoire V, Janssens G. SU-E-T-774: on the Effects of Intrafraction Motion on TomoTherapy SIB Treatments of Lung Tumors: A 4D Monte Carlo Study including Non-Rigid Registration and Beamlet-Breathing Phase Correlation Medical Physics. 38: 3669-3669. DOI: 10.1118/1.3612738  0.39
2011 Hill P, Mackie T. SU‐E‐T‐494: A Fan‐Beam Intensity Modulated Proton Therapy System Medical Physics. 38: 3602-3602. DOI: 10.1118/1.3612447  0.641
2011 Sterpin E, Chen Y, Chen Q, Lu W, Mackie T, Vynckier S. 1396 poster ON THE DOSIMETRIC CHALLENGES OF DYNAMIC JAWS TO-MOTHERAPY: A MONTE CARLO STUDY. Radiotherapy and Oncology. 99. DOI: 10.1016/S0167-8140(11)71518-3  0.424
2010 Kissick MW, Mo X, McCall KC, Schubert LK, Westerly DC, Mackie TR. A phantom model demonstration of tomotherapy dose painting delivery, including managed respiratory motion without motion management. Physics in Medicine and Biology. 55: 2983-95. PMID 20436233 DOI: 10.1088/0031-9155/55/10/012  0.364
2010 Deveau MA, Gutiérrez AN, Mackie TR, Tomé WA, Forrest LJ. Dosimetric impact of daily setup variations during treatment of canine nasal tumors using intensity-modulated radiation therapy. Veterinary Radiology & Ultrasound : the Official Journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association. 51: 90-6. PMID 20166402 DOI: 10.1111/J.1740-8261.2009.01629.X  0.407
2010 Sterpin E, Hundertmark BT, Mackie TR, Lu W, Olivera GH, Vynckier S. Monte Carlo-based analytical model for small and variable fields delivered by TomoTherapy. Radiotherapy and Oncology : Journal of the European Society For Therapeutic Radiology and Oncology. 94: 229-34. PMID 20092901 DOI: 10.1016/J.Radonc.2009.12.018  0.445
2010 Sterpin E, Lu W, Mackie T, Olivera G, Vynckier S. TH‐D‐BRB‐06: Fast and Accurate Monte Carlo‐Based Simulation of Dynamic Jaw Helical TomoTherapy Medical Physics. 37: 3467-3467. DOI: 10.1118/1.3469542  0.483
2010 Zhang M, Mackie T. WE‐B‐BRA‐04: Adaptive Intensity Modulate Proton Therapy (IMPT) for Prostate with Online Patient Realignment Medical Physics. 37: 3415-3415. DOI: 10.1118/1.3469344  0.362
2010 Wang D, Mackie T, Tomé W. WE-A-BRA-04: Characterization of Cubic Spline Path Estimate for Quantitative Proton Stopping Power Reconstruction and Bragg Peak Location Prediction Medical Physics. 37: 3410-3410. DOI: 10.1118/1.3469325  0.322
2010 Mo X, Westerly D, Mackie T. TU‐C‐BRA‐09: High‐Performance Dose Calculation for Proton Radiotherapy Using GPU Medical Physics. 37: 3383-3383. DOI: 10.1118/1.3469221  0.347
2010 Mo X, Mackie T. MO-FF-A3-01: Optimization of Spot Position in Intensity Modulated Proton Therapy Medical Physics. 37: 3364-3364. DOI: 10.1118/1.3469149  0.368
2010 Darwish N, Mackie T, Thomadsen B, Kao C. MO‐E‐204C‐03: On the Development of On‐Board PET with Tomotherapy Using Open Dual Ring Geometry Medical Physics. 37: 3357-3357. DOI: 10.1118/1.3469120  0.582
2010 Nazareth D, Mackie T, Shepard D. MO-D-202-01: Dose Calculation and Optimization Algorithms: A Clinical Perspective Medical Physics. 37: 3346-3346. DOI: 10.1118/1.3469078  0.389
2010 Zhang M, Mackie T. SU‐GG‐T‐475: Introducing and Evaluation of Energy Margin to Minimize the Dose Variation Due to Setup Uncertainty in the Distal Edge Tracking (DET) Based Intensity Modulated Proton Therapy (IMPT) Medical Physics. 37: 3296-3296. DOI: 10.1118/1.3468873  0.431
2010 Kissick M, Mo X, McCall K, Schubert L, Westerly D, Mackie T. SU‐GG‐T‐108: Optimal Management of Respiratory Motion without Motion Management: A Tomotherapy Phantom Demonstration Medical Physics. 37: 3209-3209. DOI: 10.1118/1.3468497  0.361
2009 Westerly DC, Soisson E, Chen Q, Woch K, Schubert L, Olivera G, Mackie TR. Treatment planning to improve delivery accuracy and patient throughput in helical tomotherapy. International Journal of Radiation Oncology, Biology, Physics. 74: 1290-7. PMID 19394157 DOI: 10.1016/J.Ijrobp.2009.02.004  0.324
2009 Sengbusch E, Pérez-Andújar A, DeLuca PM, Mackie TR. Maximum proton kinetic energy and patient-generated neutron fluence considerations in proton beam arc delivery radiation therapy Medical Physics. 36: 364-372. PMID 19291975 DOI: 10.1118/1.3049787  0.79
2009 Schubert LK, Westerly DC, Tomé WA, Mehta MP, Soisson ET, Mackie TR, Ritter MA, Khuntia D, Harari PM, Paliwal BR. A comprehensive assessment by tumor site of patient setup using daily MVCT imaging from more than 3,800 helical tomotherapy treatments. International Journal of Radiation Oncology, Biology, Physics. 73: 1260-9. PMID 19251098 DOI: 10.1016/J.Ijrobp.2008.11.054  0.34
2009 Westerly D, Vogelius I, Mehta M, Cannon G, Mackie T, Bentzen S. SU‐FF‐T‐519: Potential for Increased Pneumonitis Risk with IMRT as Compared to 3D‐CRT for Patients Receiving Adjuvant Chemotherapy: A Radiobiological Modeling Study Medical Physics. 36: 2643-2643. DOI: 10.1118/1.3182017  0.385
2009 Sterpin E, Mackie T, Lu W, Olivera G, Vynckier S. SU‐FF‐T‐407: Full Monte Carlo Computation of K Correction Factors Calculated in Tomotherapy Static and Helical Deliveries for Future Ion Chamber Reference Dosimetry Protocols of Non Standard Beams Medical Physics. 36: 2615-2616. DOI: 10.1118/1.3181889  0.455
2009 Kissick M, Mo X, Westerly D, Flynn R, Bowen S, Schubert L, Jeraj R, Mackie T. SU-FF-T-180: Tomotherapy Dose Painting Delivery Robust to Respiratory Motion Medical Physics. 36: 2561-2561. DOI: 10.1118/1.3181655  0.398
2009 Chang S, Deschesne K, Chen H, Weeks K, Sibata C, Carey E, Hill P, Mackie T, Marks L. SU‐FF‐T‐137: IMRT Treatment Delivery Efficiency — A Multi‐Institutional Retrospective Study Medical Physics. 36: 2551-2551. DOI: 10.1118/1.3181611  0.579
2009 Hill P, Mackie T. SU‐FF‐J‐96: Estimating Dose Uncertainty in Minimally Deformable Sites Treated Without Daily Imaging Medical Physics. 36: 2498-2498. DOI: 10.1118/1.3181388  0.619
2009 Wang D, Mackie T, Tome W. SU-FF-I-40: Proton Computed Tomography Reconstruction Using Compressed Sensing and Prior Image Constrained Compressed Sensing Medical Physics. 36: 2443-2443. DOI: 10.1118/1.3181159  0.353
2009 Sterpin E, Hundertmark B, Mackie T, Lu W, Olivera G, Vynckier S. A NEW METHOD FOR OUTPUT FACTORS MEASUREMENTS/MC COMPUTATIONS FOR STEREOTACTIC AND DYNAMIC JAWS TOMOTHERAPY Radiotherapy and Oncology. 92: S95. DOI: 10.1016/S0167-8140(12)72838-4  0.416
2009 Sengbusch E, Schubert L, Westerly D, Gondi V, Krey G, Soisson E, Tomé W, Patel R, Mackie T, Cannon G. Dosimetric Comparison of Left-sided Whole Breast Irradiation with 3DCRT, Segmental IMRT, Helical Tomotherapy, Topotherapy, and IMPT International Journal of Radiation Oncology*Biology*Physics. 75: S194-S195. DOI: 10.1016/J.Ijrobp.2009.07.451  0.769
2009 Zhang M, Mackie TR. Dosimetric Impact Due to Interfractional Motion in Sinus Cancer for Intensity Modulated Proton Radiation Therapy (IMPT) International Journal of Radiation Oncology Biology Physics. 75. DOI: 10.1016/J.Ijrobp.2009.07.287  0.328
2009 Sterpin E, Mackie T, Lu W, Olivera G, Vynckier S. Calculation of K Correction Factors with Monte Carlo Simulations in Tomotherapy Clinical Helical Deliveries for Future Ion Chamber Reference Dosimetry Protocols of Non-standard Beams International Journal of Radiation Oncology*Biology*Physics. 75: S666-S667. DOI: 10.1016/J.Ijrobp.2009.07.1521  0.47
2008 Alfonso R, Andreo P, Capote R, Huq MS, Kilby W, Kjäll P, Mackie TR, Palmans H, Rosser K, Seuntjens J, Ullrich W, Vatnitsky S. A new formalism for reference dosimetry of small and nonstandard fields. Medical Physics. 35: 5179-86. PMID 19070252 DOI: 10.1118/1.3005481  0.326
2008 Murphy S, Gutiérrez A, Lawrence J, Bjorling D, Mackie T, Forrest L. Laparoscopically implanted tissue expander radiotherapy in canine transitional cell carcinoma. Veterinary Radiology & Ultrasound : the Official Journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association. 49: 400-5. PMID 18720776 DOI: 10.1111/J.1740-8261.2008.00389.X  0.347
2008 Kissick MW, Flynn RT, Westerly DC, Hoban PW, Mo X, Soisson ET, McCall KC, Mackie TR, Jeraj R. On the impact of longitudinal breathing motion randomness for tomotherapy delivery. Physics in Medicine and Biology. 53: 4855-73. PMID 18711250 DOI: 10.1088/0031-9155/53/18/001  0.362
2008 Caporaso GJ, Mackie TR, Sampayan S, Chen YJ, Blackfield D, Harris J, Hawkins S, Holmes C, Nelson S, Paul A, Poole B, Rhodes M, Sanders D, Sullivan J, Wang L, et al. A compact linac for intensity modulated proton therapy based on a dielectric wall accelerator. Physica Medica : Pm : An International Journal Devoted to the Applications of Physics to Medicine and Biology : Official Journal of the Italian Association of Biomedical Physics (Aifb). 24: 98-101. PMID 18430600 DOI: 10.1016/J.Ejmp.2008.01.010  0.352
2008 Mackie TR, Tomé W. Advanced image-guided external beam radiotherapy Cancer Treatment and Research. 139: 7-39. PMID 18236710 DOI: 10.1007/978-0-387-36744-6_2  0.421
2008 Flynn RT, Kissick MW, Mehta MP, Olivera GH, Jeraj R, Mackie TR. The impact of linac output variations on dose distributions in helical tomotherapy Physics in Medicine and Biology. 53: 417-430. PMID 18184996 DOI: 10.1088/0031-9155/53/2/009  0.32
2008 Westerly D, Soisson E, Chen Q, Woch K, Schubert L, Olivera G, Mackie T. TU-FF-A1-05: Treatment Planning to Reduce the Impact of Delivery Errors in Helical Tomotherapy Medical Physics. 35: 2919-2919. DOI: 10.1118/1.2962642  0.373
2008 Sengbusch E, Mackie T, Perez-Andujar A, DeLuca P. SU-GG-T-526: Energy Thresholds in 180 Degree Arc Delivery Proton Therapy Medical Physics. 35: 2846-2846. DOI: 10.1118/1.2962275  0.788
2008 Zhang M, Perez‐Andujar A, Hecht A, Mackie T. SU‐GG‐T‐356: Benchmark of Geant4 and MCNPX for Proton Radiation Therapy (E<70 MeV): Total Dose and Secondary Particle Production Medical Physics. 35: 2807-2807. DOI: 10.1118/1.2962108  0.355
2008 Hecht A, Zhang M, Perez‐Andujar A, Mackie T, DeLuca P. SU‐GG‐T‐329: Investigation of Alpha Particle Beam Therapy as a Lower Neutron Dose Alternative to Proton Beams Medical Physics. 35: 2801-2801. DOI: 10.1118/1.2962081  0.352
2008 Kissick M, Flynn R, Westerly D, Hoban P, Mo X, Soisson E, McCall K, Mackie T, Jeraj R. SU-GG-T-115: The Impact of Longitudinal Breathing Randomness for Tomotherapy Delivery Medical Physics. 35: 2752-2752. DOI: 10.1118/1.2961867  0.389
2008 Mo X, Mackie T. SU-GG-T-111: A Simulation Study of An Online Adaptive Treatment Technique for Tomotherapy to Reduce Intra-Fraction Motion Effects Medical Physics. 35: 2751-2751. DOI: 10.1118/1.2961863  0.38
2008 Kissick M, Schubert L, Mackie T, Sidney D. SU‐GG‐T‐86: A Clinical Example of the Helical Tomotherapy Thread Effect: Robustness Discussion Medical Physics. 35: 2745-2746. DOI: 10.1118/1.2961838  0.318
2008 Schubert L, Rasmussen K, Westerly D, Adkison J, Mackie T, Ritter M, Tome W, Paliwal B. SU-GG-J-79: Effect of Body Weight On Patient Setup for Prostate Helical Tomotherapy Treatments Medical Physics. 35: 2697-2697. DOI: 10.1118/1.2961629  0.306
2007 Gutíerrez AN, Deveau M, Forrest LJ, Tomé WA, Mackie TR. Radiobiological and treatment planning study of a simultaneously integrated boost for canine nasal tumors using helical tomotherapy. Veterinary Radiology & Ultrasound : the Official Journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association. 48: 594-602. PMID 18018736 DOI: 10.1111/J.1740-8261.2007.00304.X  0.329
2007 Kissick MW, Flynn RT, Westerly DC, Mackie TR, Hoban PW. On the making of sharp longitudinal dose profiles with helical tomotherapy. Physics in Medicine and Biology. 52: 6497-510. PMID 17951858 DOI: 10.1088/0031-9155/52/21/011  0.393
2007 Flynn RT, Barbee DL, Mackie TR, Jeraj R. Comparison of intensity modulated x-ray therapy and intensity modulated proton therapy for selective subvolume boosting: A phantom study Physics in Medicine and Biology. 52: 6073-6091. PMID 17921573 DOI: 10.1088/0031-9155/52/20/001  0.394
2007 Becker SJ, Patel RR, Mackie TR. Increased skin dose with the use of a custom mattress for prone breast radiotherapy. Medical Dosimetry : Official Journal of the American Association of Medical Dosimetrists. 32: 196-9. PMID 17707199 DOI: 10.1016/J.Meddos.2007.01.011  0.647
2007 Zhang T, Lu W, Olivera GH, Keller H, Jeraj R, Manon R, Mehta M, Mackie TR, Paliwal B. Breathing-synchronized delivery: a potential four-dimensional tomotherapy treatment technique. International Journal of Radiation Oncology, Biology, Physics. 68: 1572-8. PMID 17570608 DOI: 10.1016/J.Ijrobp.2007.02.054  0.609
2007 Patel RR, Becker SJ, Das RK, Mackie TR. A dosimetric comparison of accelerated partial breast irradiation techniques: multicatheter interstitial brachytherapy, three-dimensional conformal radiotherapy, and supine versus prone helical tomotherapy. International Journal of Radiation Oncology, Biology, Physics. 68: 935-42. PMID 17467923 DOI: 10.1016/J.Ijrobp.2007.03.005  0.629
2007 Kissick MW, Mackie TR, Jeraj R. A delivery transfer function (DTF) analysis for helical tomotherapy. Physics in Medicine and Biology. 52: 2355-65. PMID 17440239 DOI: 10.1088/0031-9155/52/9/002  0.387
2007 Kissick M, Flynn R, Westerly D, Jeraj R, Mackie T. TH-C-M100F-03: One Vision of the Next Generation of Helical Tomotherapy Medical Physics. 34: 2631-2631. DOI: 10.1118/1.2761681  0.352
2007 Mackie T, Caporaso G, Sampayan S, Chen Y, Blackfield D, Harris J, Hawkins S, Holmes C, Nelson S, Paul A, Poole B, Rhodes M, Sanders D, Sullivan J, Wang L, et al. TH-C-AUD-09: A Proposal for a Novel Compact Intensity Modulated Proton Therapy System Using a Dielectric Wall Accelerator Medical Physics. 34: 2628-2628. DOI: 10.1118/1.2761668  0.33
2007 Tewatia D, Mackie T. TH‐C‐L100F‐03: Comparison of Imaging Capabilities of Two IGRT Systems Medical Physics. 34: 2619-2619. DOI: 10.1118/1.2761630  0.37
2007 Gutierrez A, Deveau M, Forrest L, Tomé W, Mackie T. TU-EE-A2-03: Simultaneous Integrated Boost for Canine Nasal Tumors Using Helical Tomotherapy: A Radiobiological and Treatment Planning Study Medical Physics. 34: 2567-2567. DOI: 10.1118/1.2761424  0.316
2007 Flynn R, Barbee D, Bowen S, McCall K, Bentzen S, Mackie T, Jeraj R. MO-D-M100J-01: Dose Painting With Intensity Modulated Proton Therapy and Intensity Modulated X-Ray Therapy: A Comparison Medical Physics. 34: 2522-2523. DOI: 10.1118/1.2761242  0.423
2007 Jaradat H, Paliwal B, Tome W, Mackie T, Mehta M. SU-FF-T-443: Validation of Tomotherapy Machine Matching Procedure at the University of Wisconsin Medical Physics. 34: 2503-2503. DOI: 10.1118/1.2761168  0.358
2007 Zhang M, Westerly D, Mackie T. SU‐FF‐T‐389: Study of Surface Dose Distribution in Sinus Cancer Medical Physics. 34: 2491-2491. DOI: 10.1118/1.2761114  0.369
2007 Mo X, Mackie T, Kissick M. SU‐FF‐T‐45: A Simulation Study of Intra‐Fraction Motion Effects On the Proton Discrete Scanning Treatment Medical Physics. 34: 2411-2411. DOI: 10.1118/1.2760693  0.413
2007 Gutiérrez A, Westerly D, Tomé W, Jaradat H, Mackie T, Bentzen S, Khuntia D, Mehta M. Whole Brain Radiation Therapy With Hippocampal Avoidance and Simultaneously Integrated Brain Metastases Boost With Helical Tomotherapy: A Planning Study International Journal of Radiation Oncology*Biology*Physics. 69: S674-S675. DOI: 10.1016/J.Ijrobp.2007.07.2033  0.357
2006 Boswell S, Tomé W, Jeraj R, Jaradat H, Mackie TR. Automatic registration of megavoltage to kilovoltage CT images in helical tomotherapy: an evaluation of the setup verification process for the special case of a rigid head phantom. Medical Physics. 33: 4395-404. PMID 17153418 DOI: 10.1118/1.2349698  0.69
2006 Welsh JS, Lock M, Harari PM, Tomé WA, Fowler J, Mackie TR, Ritter M, Kapatoes J, Forrest L, Chappell R, Paliwal B, Mehta MP. Clinical implementation of adaptive helical tomotherapy: a unique approach to image-guided intensity modulated radiotherapy. Technology in Cancer Research & Treatment. 5: 465-79. PMID 16981789 DOI: 10.1177/153303460600500503  0.397
2006 Mackie TR. History of tomotherapy Physics in Medicine and Biology. 51. PMID 16790916 DOI: 10.1088/0031-9155/51/13/R24  0.388
2006 Aoyama H, Westerly DC, Mackie TR, Olivera GH, Bentzen SM, Patel RR, Jaradat H, Tome WA, Ritter MA, Mehta MP. Integral radiation dose to normal structures with conformal external beam radiation. International Journal of Radiation Oncology, Biology, Physics. 64: 962-7. PMID 16458781 DOI: 10.1016/J.Ijrobp.2005.11.005  0.37
2006 Cadman P, Mackie T, Reckwerdt P. Po‐Thur Eve General‐33: Feasibility of a Multileaf Collimator and Method for Multi‐slice Tomotherapy Medical Physics. 33: 2666-2666. DOI: 10.1118/1.2244660  0.39
2006 Mackie T, Kissick M, Flynn R, Westerly D, Hill P, DeLuca P, Jeraj R, Schreuder A, Farr J. TH-E-ValA-02: Simultaneous Multi-Pencil Fan-Beam-Based Intensity-Modulated Proton Therapy. Medical Physics. 33: 2296-2296. DOI: 10.1118/1.2241971  0.6
2006 Tome W, Jaradat H, Westerly D, Fenwick J, Orton N, Mackie T, Paliwal B. TH-D-224A-01: QA for Tomotherapy Medical Physics. 33: 2282-2282. DOI: 10.1118/1.2241911  0.388
2006 Flynn R, Kissick M, Jeraj R, Mackie T, Mehta M, Olivera G, Srinavasan S. SU-FF-T-369: Propagation of Linac Output and Fluence Discretization Error to Dose Distributions in IMRT Medical Physics. 33: 2130-2131. DOI: 10.1118/1.2241287  0.309
2006 Shaw R, Mackie T. SU-FF-T-338: MVCT Superiority Over KVCT in Assessment of Electron Density for Treatment Planning Medical Physics. 33: 2124-2124. DOI: 10.1118/1.2241260  0.332
2006 Cadman P, Mackie T, Reckwerdt P. SU‐FF‐T‐336: Multi‐Slice Tomotherapy Delivery Methods Using a Novel Multileaf Collimator Medical Physics. 33: 2124-2124. DOI: 10.1118/1.2241258  0.391
2006 Gutiérrez A, Boswell S, Mackie T. SU-FF-T-150: Consequence of CT Couch Sag in Radiation Therapy Medical Physics. 33: 2083-2083. DOI: 10.1118/1.2241074  0.694
2006 Becker SJ, Shaw RA, Flynn RT, Mackie TR. SU‐FF‐T‐41: A Novel Tomotherapy Design for the Breast Medical Physics. 33: 2059-2059. DOI: 10.1118/1.2240942  0.669
2006 Kissick M, Mackie T, Jeraj R. SU-FF-T-01: A Delivery Transfer Function (DTF) Analysis of Helical Tomotherapy Medical Physics. 33: 2051-2051. DOI: 10.1118/1.2240908  0.366
2006 Becker S, Patel R, Mackie T. 2037 International Journal of Radiation Oncology*Biology*Physics. 66: S230. DOI: 10.1016/J.Ijrobp.2006.07.439  0.592
2006 Olivera GH, Mackie TR, Ruchala K, Lu W, Kapatoes J. Adaptive radiation therapy (ART) strategies using helical tomotherapy Image-Guided Imrt. 235-246. DOI: 10.1007/3-540-30356-1_19  0.507
2005 Hui SK, Kapatoes J, Fowler J, Henderson D, Olivera G, Manon RR, Gerbi B, Mackie TR, Welsh JS. Feasibility study of helical tomotherapy for total body or total marrow irradiation. Medical Physics. 32: 3214-24. PMID 16279075 DOI: 10.1118/1.2044428  0.406
2005 Kissick MW, Boswell SA, Jeraj R, Mackie TR. Confirmation, refinement, and extension of a study in intrafraction motion interplay with sliding jaw motion. Medical Physics. 32: 2346-50. PMID 16121591 DOI: 10.1118/1.1935774  0.633
2005 Boswell SA, Jeraj R, Ruchala KJ, Olivera GH, Jaradat HA, James JA, Gutierrez A, Pearson D, Frank G, Mackie TR. A novel method to correct for pitch and yaw patient setup errors in helical tomotherapy. Medical Physics. 32: 1630-9. PMID 16013722 DOI: 10.1118/1.1914543  0.659
2005 Kissick MW, Fenwick J, James JA, Jeraj R, Kapatoes JM, Keller H, Mackie TR, Olivera G, Soisson ET. The helical tomotherapy thread effect Medical Physics. 32: 1414-1423. PMID 15984692 DOI: 10.1118/1.1896453  0.389
2005 Sheng K, Jeraj R, Shaw R, Mackie TR, Paliwal BR. Imaging dose management using multi-resolution in CT-guided radiation therapy. Physics in Medicine and Biology. 50: 1205-19. PMID 15798317 DOI: 10.1088/0031-9155/50/6/011  0.391
2005 Jeraj R, Mackie TR, Balog J, Olivera G. Dose calibration of nonconventional treatment systems applied to helical tomotherapy. Medical Physics. 32: 570-7. PMID 15789604 DOI: 10.1118/1.1855015  0.314
2005 Lu W, Olivera GH, Chen ML, Reckwerdt PJ, Mackie TR. Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels. Physics in Medicine and Biology. 50: 655-80. PMID 15773626 DOI: 10.1088/0031-9155/50/4/007  0.526
2005 Lu W, Olivera GH, Mackie TR. Motion-encoded dose calculation through fluence/sinogram modification. Medical Physics. 32: 118-27. PMID 15719962 DOI: 10.1118/1.1829402  0.553
2005 Al-Sadah J, Madsen E, Mackie T, Zagzebski J. TH-C-I-609-07: Multi-Resolution Rigid Registration of Ultrasound and CT Based On Similarity Measures Medical Physics. 32: 2155-2155. DOI: 10.1118/1.1998632  0.59
2005 Shaw R, Kissick M, Mackie T, Jeraj R. WE-D-I-6B-04: Extracting CT Data in An Image-Guided Radiotherapy Benchtop Where Continuous Radiation Contaminates Image Data Medical Physics. 32: 2131-2131. DOI: 10.1118/1.1998540  0.355
2005 Zhang T, Pyzalski R, Jaskowiak C, Tome W, Mackie T, Paliwal B. TU-C-J-6B-03: Deformable Fusion of 4D PET Images Medical Physics. 32: 2082-2082. DOI: 10.1118/1.1998347  0.548
2005 Olivera G, Ruchala K, Lu W, Haimerl J, Schnarr E, Langen K, Kupelian P, Meeks S, Mackie T. SU-FF-T-363: Dynamic Tangents and Topotherapy: New Delivery Capabilities for Helical Tomotherapy Medical Physics. 32: 2034-2034. DOI: 10.1118/1.1998092  0.556
2005 Becker S, Jeraj R, Mackie T. SU-FF-T-218: Skin Dose Due to a Supporting Pad in Prone Breast Treatments Medical Physics. 32: 2000-2000. DOI: 10.1118/1.1997946  0.645
2005 James J, Nelson I, Mackie T. SU-FF-T-195: Evaluation of Film Calibration Procedures for Quality Assurance of Helical Tomotherapy Treatments Medical Physics. 32: 1994-1994. DOI: 10.1118/1.1997923  0.372
2005 Mackie T, Flynn R, Kissick M, Jeraj R. SU-FF-T-99: An Analysis of Intensity Discretization Errors in IMRT Medical Physics. 32: 1972-1972. DOI: 10.1118/1.1997770  0.347
2005 Westerly D, Aoyama H, Patel R, Jaradat H, Olivera G, Tome W, Ritter M, Mehta M, Mackie T. SU-FF-T-82: Non-Tumor Integral Dose in Conformal, External Beam Radiation Therapy Medical Physics. 32: 1968-1968. DOI: 10.1118/1.1997753  0.418
2005 Kissick M, Boswell S, Jeraj R, Mackie T. SU-FF-J-124: The Unappreciated Benefits of Randomness and Slow Delivery with Organ Motion Medical Physics. 32: 1948-1949. DOI: 10.1118/1.1997670  0.686
2005 Gutierrez A, Murphy S, Jaradat H, Forrest L, Mackie T. SU-FF-J-76: Minimally-Invasive Intraoperative Radiotherapy (MIR): Technique Development for Treatment of Canine Bladder Cancer Medical Physics. 32: 1937-1937. DOI: 10.1118/1.1997622  0.353
2005 Flynn R, Jeraj R, Mackie T. SU-FF-J-46: A Probabilistic Method for Online Treatment Plan Modification Medical Physics. 32: 1930-1930. DOI: 10.1118/1.1997592  0.352
2005 Hui S, Gerbi B, Kapatoes J, Olivera G, Henderson D, Manon R, Mackie T, Welsh J, Fowler J. SU-EE-A1-02: Feasibility Study of Helical Tomotherapy for Total Body and Total Marrow Irradiation Medical Physics. 32: 1902-1902. DOI: 10.1118/1.1997472  0.374
2005 Sheng K, Shaw R, Jeraj R, Mackie T, Paliwal B. SU-DD-A3-02: Slice Based Image Guidance with Tomotherapy Medical Physics. 32: 1893-1893. DOI: 10.1118/1.1997425  0.431
2005 Becker S, Patel R, Mackie T. 143 4DCT intrafraction motion margin assessment in breast cancer treatments Radiotherapy and Oncology. 76: S74. DOI: 10.1016/S0167-8140(05)81119-3  0.605
2005 Pates R, Becker S, Das R, Mackie T. 44 A Dosimetric Comparison of Partial Breast Irradiation Techniques Following Lumpectomy: Multi-catheter Interstitial Brachytherapy, 3D-CRT, and Helical Tomotherapy Radiotherapy and Oncology. 76. DOI: 10.1016/S0167-8140(05)81022-9  0.31
2005 Boswell S, Tome W, Jaradat H, Mackie T. Comparison of Automatic Tomotherapy CT Setup Verification vs. an Optically Guided Patient Positioning System International Journal of Radiation Oncology*Biology*Physics. 63: S532. DOI: 10.1016/J.Ijrobp.2005.07.898  0.662
2005 Becker SJ, Patel R, Mackie T. Accelerated Partial Breast Irradiation: A Dosimetric Comparison Between Interstitial Brachytherapy, 3D-CRT, and Prone Helical Tomotherapy International Journal of Radiation Oncology Biology Physics. 63. DOI: 10.1016/J.Ijrobp.2005.07.311  0.618
2004 Forrest LJ, Mackie TR, Ruchala K, Turek M, Kapatoes J, Jaradat H, Hui S, Balog J, Vail DM, Mehta MP. The utility of megavoltage computed tomography images from a helical tomotherapy system for setup verification purposes International Journal of Radiation Oncology Biology Physics. 60: 1639-1644. PMID 15590196 DOI: 10.1016/J.Ijrobp.2004.08.016  0.369
2004 Hui SK, Das RK, Kapatoes J, Oliviera G, Becker S, Odau H, Fenwick JD, Patel R, Kuske R, Mehta M, Paliwal B, Mackie TR, Fowler JF, Welsh JS. Helical tomotherapy as a means of delivering accelerated partial breast irradiation. Technology in Cancer Research & Treatment. 3: 639-46. PMID 15560722 DOI: 10.1177/153303460400300614  0.428
2004 Zhang T, Orton NP, Mackie TR, Paliwal BR. Technical note: A novel boundary condition using contact elements for finite element based deformable image registration. Medical Physics. 31: 2412-5. PMID 15487720 DOI: 10.1118/1.1774131  0.459
2004 Lu W, Chen ML, Olivera GH, Ruchala KJ, Mackie TR. Fast free-form deformable registration via calculus of variations. Physics in Medicine and Biology. 49: 3067-87. PMID 15357182 DOI: 10.1088/0031-9155/49/14/003  0.51
2004 Fenwick JD, Tomé WA, Jaradat HA, Hui SK, James JA, Balog JP, DeSouza CN, Lucas DB, Olivera GH, Mackie TR, Paliwal BR. Quality assurance of a helical tomotherapy machine. Physics in Medicine and Biology. 49: 2933-53. PMID 15285257 DOI: 10.1088/0031-9155/49/13/012  0.364
2004 Zhang T, Jeraj R, Keller H, Lu W, Olivera GH, McNutt TR, Mackie TR, Paliwal B. Treatment plan optimization incorporating respiratory motion. Medical Physics. 31: 1576-86. PMID 15259662 DOI: 10.1118/1.1739672  0.65
2004 Welsh JS, Bradley K, Ruchala KJ, Mackie TR, Mañon R, Patel R, Wiederholt P, Lock M, Hui S, Mehta MP. Megavoltage computed tomography imaging: a potential tool to guide and improve the delivery of thoracic radiation therapy. Clinical Lung Cancer. 5: 303-6. PMID 15086969 DOI: 10.3816/Clc.2004.N.010  0.401
2004 Jeraj R, Mackie TR, Balog J, Olivera G, Pearson D, Kapatoes J, Ruchala K, Reckwerdt P. Radiation characteristics of helical tomotherapy. Medical Physics. 31: 396-404. PMID 15000626 DOI: 10.1118/1.1639148  0.41
2004 Wu C, Jeraj R, Lu W, Mackie TR. Fast treatment plan modification with an over-relaxed Cimmino algorithm. Medical Physics. 31: 191-200. PMID 15000604 DOI: 10.1118/1.1631913  0.589
2004 Keller H, Tomé W, Ritter MA, Mackie TR. Design of adaptive treatment margins for non-negligible measurement uncertainty: Application to ultrasound-guided prostate radiation therapy Physics in Medicine and Biology. 49: 69-86. PMID 14971773 DOI: 10.1088/0031-9155/49/1/005  0.348
2003 Zhang T, Keller H, O'Brien MJ, Mackie TR, Paliwal B. Application of the spirometer in respiratory gated radiotherapy. Medical Physics. 30: 3165-71. PMID 14713083 DOI: 10.1118/1.1625439  0.508
2003 Jeraj R, Wu C, Mackie TR. Optimizer convergence and local minima errors and their clinical importance. Physics in Medicine and Biology. 48: 2809-27. PMID 14516103 DOI: 10.1088/0031-9155/48/17/306  0.458
2003 Miao B, Jeraj R, Bao S, Mackie TR. Adaptive anisotropic diffusion filtering of Monte Carlo dose distributions. Physics in Medicine and Biology. 48: 2767-81. PMID 14516100 DOI: 10.1088/0031-9155/48/17/303  0.321
2003 Wu C, Olivera GH, Jeraj R, Keller H, Mackie TR. Treatment plan modification using voxel-based weighting factors/dose prescription. Physics in Medicine and Biology. 48: 2479-91. PMID 12953910 DOI: 10.1088/0031-9155/48/15/315  0.517
2003 Balog J, Mackie TR, Pearson D, Hui S, Paliwal B, Jeraj R. Benchmarking beam alignment for a clinical helical tomotherapy device. Medical Physics. 30: 1118-27. PMID 12852536 DOI: 10.1118/1.1576395  0.347
2003 Wu C, Jeraj R, Mackie TR. The method of intercepts in parameter space for the analysis of local minima caused by dose-volume constraints. Physics in Medicine and Biology. 48: N149-57. PMID 12817946 DOI: 10.1088/0031-9155/48/11/402  0.51
2003 Mackie TR, Kapatoes J, Ruchala K, Lu W, Wu C, Olivera G, Forrest L, Tome W, Welsh J, Jeraj R, Harari P, Reckwerdt P, Paliwal B, Ritter M, Keller H, et al. Image guidance for precise conformal radiotherapy. International Journal of Radiation Oncology, Biology, Physics. 56: 89-105. PMID 12694827 DOI: 10.1016/S0360-3016(03)00090-7  0.591
2003 Sheng K, Jeraj R, Keller H, Mackie T, Paliwal B. A phantom study of intra-fractional image acquisition and dose calculation International Journal of Radiation Oncology*Biology*Physics. 57: S187-S188. DOI: 10.1016/S0360-3016(03)00983-0  0.356
2003 Zhang T, Keller H, Jeraj R, Manon R, Welsh J, Patel R, Fenwick J, Mehta M, Mackie T, Paliwal B. Breathing synchronized delivery — a new technique for radiation treatment of the targets with respiratory motion International Journal of Radiation Oncology*Biology*Physics. 57: S185-S186. DOI: 10.1016/S0360-3016(03)00980-5  0.538
2002 Ruchala KJ, Olivera GH, Kapatoes JM, Reckwerdt PJ, Mackie TR. Methods for improving limited field-of-view radiotherapy reconstructions using imperfect a priori images. Medical Physics. 29: 2590-605. PMID 12462726 DOI: 10.1118/1.1513163  0.394
2002 Wu C, Jeraj R, Olivera GH, Mackie TR. Re-optimization in adaptive radiotherapy. Physics in Medicine and Biology. 47: 3181-95. PMID 12361217 DOI: 10.1088/0031-9155/47/17/309  0.548
2002 Lu W, Mackie TR. Tomographic motion detection and correction directly in sinogram space. Physics in Medicine and Biology. 47: 1267-84. PMID 12030555 DOI: 10.1088/0031-9155/47/8/304  0.494
2002 Keller H, Glass M, Hinderer R, Ruchala K, Jeraj R, Olivera G, Mackie TR. Monte Carlo study of a highly efficient gas ionization detector for megavoltage imaging and image-guided radiotherapy. Medical Physics. 29: 165-75. PMID 11865988 DOI: 10.1118/1.1445414  0.696
2002 Hinderer R, Kapatoes JM, Keller H, Schmidt R, Jeraj R, Ruchala KJ, Pearson DW, Fang G, Olivera GH, Mackie TR. Development of a new multielement detector system for megavoltage photons Proceedings of Spie - the International Society For Optical Engineering. 4682: 809-818. DOI: 10.1117/12.465632  0.674
2002 Forrest LJ, Mackie TR, Ruchala KJ, Mehta MP. Megavoltage CT images from a helical tomotherapy system International Journal of Radiation Oncology Biology Physics. 54: 333-334. DOI: 10.1016/S0360-3016(02)03632-5  0.306
2002 Olivera G, Kapatoes J, Mehta M, Ruchala K, Reckwerdt P, Jeraj R, Lu W, Mackie T. Defining the impact of beam parameters in breath-hold tomotherapy International Journal of Radiation Oncology*Biology*Physics. 54: 315-316. DOI: 10.1016/S0360-3016(02)03604-0  0.465
2002 Patel R, Tomé W, Orton N, Olivera G, Chinnaiyan P, Chappell R, Mackie T, Ritter M. The use of an endorectal balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer: a DVH analysis of rectal dose-sparing with 3D-CRT, IMRT, and helical tomotherapy International Journal of Radiation Oncology*Biology*Physics. 54: 259. DOI: 10.1016/S0360-3016(02)03507-1  0.412
2002 Sheng K, Jeraj R, Mackie T, Paliwal B, Das R, Tome W. Concurrent geometry and dose reconstruction in image guided radiation therapy International Journal of Radiation Oncology*Biology*Physics. 54: 123. DOI: 10.1016/S0360-3016(02)03269-8  0.366
2001 Kapatoes JM, Olivera GH, Ruchala KJ, Mackie TR. On the verification of the incident energy fluence in tomotherapy IMRT. Physics in Medicine and Biology. 46: 2953-65. PMID 11720357 DOI: 10.1088/0031-9155/46/11/313  0.377
2001 Kapatoes JM, Olivera GH, Ruchala KJ, Smilowitz JB, Reckwerdt PJ, Mackie TR. A feasible method for clinical delivery verification and dose reconstruction in tomotherapy. Medical Physics. 28: 528-42. PMID 11339750 DOI: 10.1118/1.1352579  0.747
2001 Kapatoes JM, Olivera GH, Balog JP, Keller H, Reckwerdt PJ, Mackie TR. On the accuracy and effectiveness of dose reconstruction for tomotherapy. Physics in Medicine and Biology. 46: 943-66. PMID 11324970 DOI: 10.1088/0031-9155/46/4/303  0.411
2001 Keller H, Hinderer R, Glass M, Jeraj R, Schmidt R, Fang G, Kapatoes J, Mackie TR. Design considerations for efficient binary megavoltage photon detector structures Ieee Nuclear Science Symposium and Medical Imaging Conference. 3: 1704-1706. DOI: 10.1109/TNS.2002.807880  0.632
2001 Song S, Tome W, Olivera G, Smilowitz J, Paliwal B, Mackie T, Kuske R. Accelerated intensity modulated partial breast radiation therapy in prone position International Journal of Radiation Oncology*Biology*Physics. 51: 398-399. DOI: 10.1016/S0360-3016(01)02558-5  0.71
2001 Olivera G, Ruchala K, Kapatoes J, Reckwerdt P, Jeraj R, Lu W, Balog J, Mackie T. Approaches to prostate patient setup including daily anatomy changes International Journal of Radiation Oncology*Biology*Physics. 51: 384-385. DOI: 10.1016/S0360-3016(01)02533-0  0.41
2001 Ruchala K, Olivera G, Kapatoes J, Lu W, Reckwerdt P, Mackie T. Overcoming limited field-of-view problems of on-board CT for improved radiotherapy patient positioning and dose accumulation International Journal of Radiation Oncology*Biology*Physics. 51: 95-96. DOI: 10.1016/S0360-3016(01)01999-X  0.503
2001 Kapatoes J, Olivera G, Schloesser E, Pearson D, Balog J, Ruchala K, Schmidt R, Reckwerdt P, Mehta M, Mackie T. Gating-by-rotation: a solution to the problem of intratreatment motion in helical tomotherapy International Journal of Radiation Oncology*Biology*Physics. 51: 95. DOI: 10.1016/S0360-3016(01)01998-8  0.369
2001 Michalski J, Purdy JA, Gaspar L, Souhami L, Ballow M, Bradley J, Chao CKS, Crane C, Eisbruch A, Fallowil D, Forster K, Fowler J, Gillin M, Graham ML, Harms WB, ... ... Mackie TR, et al. Image-Guided Radiation Therapy Committee International Journal of Radiation Oncology Biology Physics. 51: 60-65. DOI: 10.1016/S0360-3016(01)01784-9  0.318
2000 Ruchala KJ, Olivera GH, Kapatoes JM, Schloesser EA, Reckwerdt PJ, Mackie TR. Megavoltage CT image reconstruction during tomotherapy treatments. Physics in Medicine and Biology. 45: 3545-62. PMID 11131183 DOI: 10.1088/0031-9155/45/12/303  0.367
2000 Ruchala KJ, Olivera GH, Kapatoes JM, Schloesser EA, Reckwerdt PJ, Mackie TR. Megavoltage CT imaging as a by-product of multileaf collimator leakage Physics in Medicine and Biology. 45. PMID 10943938 DOI: 10.1088/0031-9155/45/7/401  0.407
2000 Ruchala KJ, Olivera GH, Schloesser EA, Hinderer R, Mackie TR. Calibration of a tomotherapeutic MVCT system. Physics in Medicine and Biology. 45: N27-36. PMID 10795996 DOI: 10.1088/0031-9155/45/4/404  0.716
2000 Shepard DM, Olivera GH, Reckwerdt PJ, Mackie TR. Iterative approaches to dose optimization in tomotherapy Physics in Medicine and Biology. 45: 69-90. PMID 10661584 DOI: 10.1088/0031-9155/45/1/306  0.308
2000 Kapatoes J, Olivera G, Lu W, Reckwerdt P, Keller H, Balog J, Mackie T. Dose gradients as a tool in the optimization and verification of intensity modulated radiation therapy (IMRT) International Journal of Radiation Oncology*Biology*Physics. 48: 139-140. DOI: 10.1016/S0360-3016(00)80074-7  0.5
2000 Modrick JM, Mackie TR, Thomadsen BR. Energy deposition kernels at low photon energy including coherent scatter Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 2: 1078-1081.  0.48
2000 Ruchala KJ, Olivera GH, Schloesser EA, Hinderer R, Mackie TR. Tomotherapeutic megavoltage CT calibration Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 3: 2045-2048.  0.666
2000 Smilowitz J, Balog J, Keller H, Olivera G, DeWerd LA, Mackie TR. A new multipurpose quality assurance phantom for clinical tomotherapy Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 2: 1191-1194.  0.565
1999 Ruchala KJ, Olivera GH, Schloesser EA, Mackie TR. Megavoltage CT on a tomotherapy system Physics in Medicine and Biology. 44: 2597-2621. PMID 10533931 DOI: 10.1088/0031-9155/44/10/316  0.372
1999 Aldridge JS, Reckwerdt PJ, Mackie TR. A proposal for a standard electronic anthropomorphic phantom for radiotherapy. Medical Physics. 26: 1901-3. PMID 10505879 DOI: 10.1118/1.598696  0.307
1999 Lu W, Fitchard EE, Olivera GH, You J, Ruchala KJ, Aldridge JS, Mackie TR. Image/patient registration from (partial) projection data by the Fourier phase matching method. Physics in Medicine and Biology. 44: 2029-48. PMID 10473212 DOI: 10.1088/0031-9155/44/8/313  0.479
1999 Kapatoes JM, Olivera GH, Reckwerdt PJ, Fitchard EE, Schloesser EA, Mackie TR. Delivery verification in sequential and helical tomotherapy. Physics in Medicine and Biology. 44: 1815-41. PMID 10442715 DOI: 10.1088/0031-9155/44/7/318  0.411
1999 Mackie TR, Smith AR. Intensity-modulated conformal radiation therapy and 3-dimensional treatment planning will significantly reduce the need for therapeutic approaches with particles such as protons. Medical Physics. 26: 1185-7. PMID 10435517 DOI: 10.1118/1.598638  0.346
1999 McGary JE, Boyer AL, Mackie TR. A comparison of Monte Carlo and analytic first scatter dose spread arrays Medical Physics. 26: 751-759. PMID 10360537 DOI: 10.1118/1.598583  0.309
1999 Zhang GG, Rogers DWO, Cygler JE, Mackie TR. Monte Carlo investigation of electron beam output factors versus size of square cutout Medical Physics. 26: 743-750. PMID 10360536 DOI: 10.1118/1.598582  0.361
1999 Balog JP, Mackie TR, Wenman DL, Glass M, Fang G, Pearson D. Multileaf collimator interleaf transmission Medical Physics. 26: 176-186. PMID 10076971 DOI: 10.1118/1.598501  0.331
1999 Balog JP, Mackie TR, Reckwerdt P, Glass M, Angelos L. Characterization of the output for helical delivery of intensity modulated slit beams Medical Physics. 26: 55-64. PMID 9949398 DOI: 10.1118/1.598477  0.376
1999 Fitchard EE, Aldridge JS, Reckwerdt PJ, Olivera GH, Mackie TR, Iosevich A. Six parameter patient registration directly from projection data Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 421: 342-351. DOI: 10.1016/S0168-9002(98)01236-4  0.307
1998 Olivera GH, Shepard DM, Reckwerdt PJ, Ruchala K, Zachman J, Fitchard EE, Mackie TR. Maximum likelihood as a common computational framework in tomotherapy Physics in Medicine and Biology. 43: 3277-3294. PMID 9832016 DOI: 10.1088/0031-9155/43/11/008  0.387
1998 Zhang GG, Rogers DWO, Cygler JE, Mackie TR. Effects of changes in stopping-power ratios with field size on electron beam relative output factors Medical Physics. 25: 1711-1716. PMID 9775377 DOI: 10.1118/1.598351  0.319
1998 Paliwal BR, Ritter MA, McNutt TR, Mackie TR, Thomadsen BR, Purdy JA, Kinsella TJ. A solid water pelvic and prostate phantom for imaging, volume rendering, treatment planning, and dosimetry for an RTOG multi-institutional, 3-D dose escalation study International Journal of Radiation Oncology Biology Physics. 42: 205-211. PMID 9747839 DOI: 10.1016/S0360-3016(98)00187-4  0.573
1998 Forrest LJ, Mahler PA, Vail DM, Mackie TR, Ladd WM, Kinsella TJ. Computed tomographic evaluation of radiation pneumonitis in a canine model Radiation Oncology Investigations. 6: 128-134. PMID 9652911 DOI: 10.1002/(Sici)1520-6823(1998)6:3<128::Aid-Roi3>3.0.Co;2-#  0.368
1997 McNutt TR, Mackie TR, Paliwal BR. Analysis and convergence of the iterative convolution/superposition dose reconstruction technique for multiple treatment beams and tomotherapy. Medical Physics. 24: 1465-76. PMID 9304575 DOI: 10.1118/1.598035  0.416
1997 Yang JN, Mackie TR, Reckwerdt P, Deasy JO, Thomadsen BR. An investigation of tomotherapy beam delivery. Medical Physics. 24: 425-36. PMID 9089594 DOI: 10.1118/1.597909  0.637
1997 Ma CM, Faddegon BA, Rogers DWO, Mackie TR. Accurate characterization of Monte Carlo calculated electron beams for radiotherapy Medical Physics. 24: 401-416. PMID 9089592 DOI: 10.1118/1.597908  0.383
1997 Ding GX, Rogers DWO, Cygler JE, Mackie TR. Electron fluence correction factors for conversion of dose in plastic to dose in water Medical Physics. 24: 161-176. PMID 9048356 DOI: 10.1118/1.597930  0.368
1996 McNutt TR, Mackie TR, Reckwerdt P, Papanikolaou N, Paliwal BR. Calculation of portal dose using the convolution/superposition method. Medical Physics. 23: 527-35. PMID 9157266 DOI: 10.1118/1.597810  0.48
1996 Ding GX, Rogers DWO, Mackie TR. Mean energy, energy-range relationships and depth-scaling factors for clinical electron beams Medical Physics. 23: 361-376. PMID 8815379 DOI: 10.1118/1.597788  0.328
1995 Rogers DWO, Faddegon BA, Ding GX, Ma CM, We J, Mackie TR. BEAM: A Monte Carlo code to simulate radiotherapy treatment units Medical Physics. 22: 503-524. PMID 7643786 DOI: 10.1118/1.597552  0.38
1995 Dina GX, Rogers DWO, Mackie TR. Calculation of stopping-power ratios using realistic clinical electron beams Medical Physics. 22: 489-501. PMID 7643785 DOI: 10.1118/1.597581  0.338
1995 Yu CX, Mackie TR, Wong JW. Photon dose calculation incorporating explicit electron transport Medical Physics. 22: 1157-1165. PMID 7565390 DOI: 10.1118/1.597611  0.346
1995 Deasy J, Mackie T, DeLuca P. Comformal proton tomotherapy using distaledge tracking Radiotherapy and Oncology. 37: S43. DOI: 10.1016/0167-8140(96)80599-8  0.359
1995 Mackie TR, Holmes TW, Reckwerdt PJ, Yang J. Tomotherapy: Optimized planning and delivery of radiation therapy International Journal of Imaging Systems and Technology. 6: 43-55. DOI: 10.1002/ima.1850060107  0.336
1994 Holmes T, Mackie TR. A comparison of three inverse treatment planning algorithms. Physics in Medicine and Biology. 39: 91-106. PMID 7652002 DOI: 10.1088/0031-9155/39/1/006  0.36
1993 Thomadsen BR, Kubsad SS, Paliwal BR, Shahabi S, Mackie TR. On the cause of the variation in tissue-maximum ratio values with source-to-detector distance Medical Physics. 20: 723-727. PMID 8350825 DOI: 10.1118/1.597022  0.58
1993 Holmes MA, MacKie TR, Sohn W, Reckwerdt PJ, Kinsella TJ, Bielajew AF, Rogers DWO. The application of correlated sampling to the computation of electron beam dose distributions in heterogeneous phantoms using the Monte Carlo method Physics in Medicine and Biology. 38: 675-688. PMID 8346279 DOI: 10.1088/0031-9155/38/6/003  0.378
1993 Mackie TR, Holmes T, Swerdloff S, Reckwerdt P, Deasy JO, Yang J, Paliwal B, Kinsella T. Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. Medical Physics. 20: 1709-19. PMID 8309444 DOI: 10.1118/1.596958  0.492
1993 Papanikolaou N, Mackie TR, Meger-Wells C, Gehring M, Reckwerdt P. Investigation of the convolution method for polyenergetic spectra Medical Physics. 20: 1327-1336. PMID 8289713 DOI: 10.1118/1.597154  0.475
1993 Holmes TW, Mackie TR, Swerdloff S, Reckwerdt PJ, Kinsella TJ. Tomotherapy: Inverse treatment planning for conformal radiotherapy International Journal of Radiation Oncology Biology Physics. 27: 139. DOI: 10.1016/0360-3016(93)90649-G  0.343
1992 Beddar AS, Mackie TR, Attix FH. Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements Physics in Medicine and Biology. 37: 1901-1913. PMID 1438555 DOI: 10.1088/0031-9155/37/10/007  0.646
1992 Beddar AS, Mackie TR, Attix FH. Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations Physics in Medicine and Biology. 37: 1883-1900. PMID 1438554 DOI: 10.1088/0031-9155/37/10/006  0.638
1992 Beddar AS, Mackie TR, Attix FH. Cerenkov light generated in optical fibres and other light pipes irradiated by electron beams Physics in Medicine and Biology. 37: 925-935. DOI: 10.1088/0031-9155/37/4/007  0.608
1991 Thomason C, Mackie TR, Lindstrom MJ, Higgins PD. The dose distribution surrounding 192Ir and 137Cs seed sources Physics in Medicine and Biology. 36: 475-493. PMID 2047397 DOI: 10.1088/0031-9155/36/4/006  0.323
1991 Paliwal BR, Gehring MA, Sanders C, Mackie TR, Raffety HM, Song CW. 3d rendering of SAR distributions from thermotron RF-8 using a ray casting technique International Journal of Hyperthermia. 7: 567-575. PMID 1919152 DOI: 10.3109/02656739109034969  0.335
1990 Simpkin DJ, Mackie TR. EGS4 Monte Carlo determination of the beta dose kernel in water Medical Physics. 17: 179-186. PMID 2333044 DOI: 10.1118/1.596565  0.312
1988 Mackie TR, Bielajew AF, Rogers DW, Battista JJ. Generation of photon energy deposition kernels using the EGS Monte Carlo code. Physics in Medicine and Biology. 33: 1-20. PMID 3353444 DOI: 10.1088/0031-9155/33/1/001  0.306
Show low-probability matches.