Year |
Citation |
Score |
2018 |
Li G, Chen H, Hu Y, Wang J, Guo Y, Liu J, Li H, Huang R, Lv H, Li J. An improved decision tree-based fault diagnosis method for practical variable refrigerant flow system using virtual sensor-based fault indicators Applied Thermal Engineering. 129: 1292-1303. DOI: 10.1016/J.Applthermaleng.2017.10.013 |
0.375 |
|
2017 |
Guo Y, Li G, Chen H, Hu Y, Shen L, Li H, Hu M, Li J. Development of a virtual variable-speed compressor power sensor for variable refrigerant flow air conditioning system International Journal of Refrigeration-Revue Internationale Du Froid. 74: 73-85. DOI: 10.1016/J.Ijrefrig.2016.09.025 |
0.359 |
|
2017 |
Guo Y, Li G, Chen H, Hu Y, Li H, Xing L, Hu W. An enhanced PCA method with Savitzky-Golay method for VRF system sensor fault detection and diagnosis Energy and Buildings. 142: 167-178. DOI: 10.1016/J.Enbuild.2017.03.026 |
0.383 |
|
2017 |
Guo Y, Li G, Chen H, Hu Y, Li H, Liu J, Hu M, Hu W. Modularized PCA method combined with expert-based multivariate decoupling for FDD in VRF systems including indoor unit faults Applied Thermal Engineering. 115: 744-755. DOI: 10.1016/J.Applthermaleng.2017.01.008 |
0.344 |
|
2016 |
Woradechjumroen D, Li H, Promwattanapakee T. Fault Detection and Diagnosis Process for Oversizing Design on Multiple Packaged Air-conditioning Units Procedia Computer Science. 86: 341-344. DOI: 10.1016/J.Procs.2016.05.092 |
0.384 |
|
2016 |
Woradechjumroen D, Li H, Deesiri A. Development of Coordination Control for Multiple Rooftop Units Procedia Computer Science. 86: 176-179. DOI: 10.1016/J.Procs.2016.05.050 |
0.328 |
|
2016 |
Hu Y, Li G, Chen H, Li H, Liu J. Sensitivity analysis for PCA-based chiller sensor fault detection International Journal of Refrigeration. 63: 133-143. DOI: 10.1016/J.Ijrefrig.2015.11.006 |
0.356 |
|
2016 |
Li G, Hu Y, Chen H, Li H, Hu M, Guo Y, Shi S, Hu W. A sensor fault detection and diagnosis strategy for screw chiller system using support vector data description-based D-statistic and DV-contribution plots Energy and Buildings. 133: 230-245. DOI: 10.1016/J.Enbuild.2016.09.037 |
0.375 |
|
2016 |
Li G, Hu Y, Chen H, Shen L, Li H, Hu M, Liu J, Sun K. An improved fault detection method for incipient centrifugal chiller faults using the PCA-R-SVDD algorithm Energy and Buildings. 116: 104-113. DOI: 10.1016/J.Enbuild.2015.12.045 |
0.354 |
|
2016 |
Hu Y, Chen H, Li G, Li H, Xu R, Li J. A statistical training data cleaning strategy for the PCA-based chiller sensor fault detection, diagnosis and data reconstruction method Energy and Buildings. 112: 270-278. DOI: 10.1016/J.Enbuild.2015.11.066 |
0.338 |
|
2016 |
Woradechjumroen D, Li H, Yu Y. Soft-repair technique for solving inherent oversizing effect on multiple rooftop units in commercial buildings Building and Environment. 108: 47-62. DOI: 10.1016/J.Buildenv.2016.08.020 |
0.34 |
|
2016 |
Li G, Hu Y, Chen H, Shen L, Li H, Li J, Hu W. Extending the virtual refrigerant charge sensor (VRC) for variable refrigerant flow (VRF) air conditioning system using data-based analysis methods Applied Thermal Engineering. 93: 908-919. DOI: 10.1016/J.Applthermaleng.2015.10.050 |
0.313 |
|
2016 |
Woradechjumroen D, Yu Y, Li H. Virtual partition surface temperature sensor based on linear parametric model Applied Energy. 162: 1323-1335. DOI: 10.1016/J.Apenergy.2015.07.021 |
0.35 |
|
2015 |
Yu Y, Li H. Virtual in-situ calibration method in building systems Automation in Construction. 59: 59-67. DOI: 10.1016/J.Autcon.2015.08.003 |
0.334 |
|
2015 |
Niu F, Yu Y, Yu D, Li H. Investigation on soil thermal saturation and recovery of an earth to air heat exchanger under different operation strategies Applied Thermal Engineering. 77: 90-100. DOI: 10.1016/J.Applthermaleng.2014.11.069 |
0.311 |
|
2015 |
Niu F, Yu Y, Yu D, Li H. Heat and mass transfer performance analysis and cooling capacity prediction of earth to air heat exchanger Applied Energy. 137: 211-221. DOI: 10.1016/J.Apenergy.2014.10.008 |
0.337 |
|
2014 |
Li H, Yu Y, Niu F, Shafik ME, Chen B. Performance of a coupled cooling system with earth-to-air heat exchanger and solar chimney Renewable Energy. 62: 468-477. DOI: 10.1016/J.Renene.2013.08.008 |
0.309 |
|
2014 |
Yang H, Xu Z, Xiong R, Li H, Zhang TC, Liu X, Woradechjumroen D. Simplifying manufacturers’ data in unitary HVAC equipment through a DX cooling coil modeling Energy and Buildings. 74: 152-162. DOI: 10.1016/J.Enbuild.2014.01.005 |
0.309 |
|
2014 |
Zhao X, Yang M, Li H. Field implementation and evaluation of a decoupling-based fault detection and diagnostic method for chillers Energy and Buildings. 72: 419-430. DOI: 10.1016/J.Enbuild.2014.01.003 |
0.353 |
|
2014 |
Woradechjumroen D, Yu Y, Li H, Yu D, Yang H. Analysis of HVAC system oversizing in commercial buildings through field measurements Energy and Buildings. 69: 131-143. DOI: 10.1016/J.Enbuild.2013.10.015 |
0.323 |
|
2013 |
Yang M, Zhao X, Li H, Wang W. WITHDRAWN: A smart virtual outdoor air ratio sensor in rooftop air conditioning units Applied Thermal Engineering. DOI: 10.1016/J.Applthermaleng.2013.12.046 |
0.304 |
|
2012 |
Yu Y, Liu M, Li H, Yu D, Loftness V. Synergization of air handling units for high energy efficiency in office buildings: Implementation methodology and performance evaluation Energy and Buildings. 54: 426-435. DOI: 10.1016/J.Enbuild.2012.07.018 |
0.327 |
|
2012 |
Zhao X, Yang M, Li H. A virtual condenser fouling sensor for chillers Energy and Buildings. 52: 68-76. DOI: 10.1016/J.Enbuild.2012.05.018 |
0.368 |
|
2012 |
Yu Y, Liu M, Li H, Yu D, Loftness V. Synergization of air handling units for high energy efficiency in office buildings: The theory and analysis Energy and Buildings. 45: 264-273. DOI: 10.1016/J.Enbuild.2011.11.015 |
0.333 |
|
2011 |
Yu D, Li H, Yu Y. A Gray-Box Based Virtual SCFM Meter in Rooftop Air-Conditioning Units Journal of Thermal Science and Engineering Applications. 3: 11005. DOI: 10.1115/1.4003702 |
0.396 |
|
2011 |
Li H, Yu D, Braun JE. A review of virtual sensing technology and application in building systems Hvac and R Research. 17: 619-645. DOI: 10.1080/10789669.2011.573051 |
0.498 |
|
2011 |
Yu D, Li H, Ni L, Yu Y. An improved virtual calibration of a supply air temperature sensor in rooftop air conditioning units Hvac&R Research. 17: 798-812. DOI: 10.1080/10789669.2011.562273 |
0.401 |
|
2011 |
Zhao X, Yang M, Li H. Decoupling features for fault detection and diagnosis on centrifugal chillers (1486-RP) Hvac&R Research. 17: 86-106. DOI: 10.1080/10789669.2011.543254 |
0.355 |
|
2011 |
Yu D, Li H, Yu Y, Xiong J. Virtual calibration of a supply air temperature sensor in rooftop air conditioning units Hvac&R Research. 17: 31-50. DOI: 10.1080/10789669.2011.543250 |
0.377 |
|
2011 |
Yu D, Li H, Yang M. A virtual supply airflow rate meter for rooftop air-conditioning units Building and Environment. 46: 1292-1302. DOI: 10.1016/J.Buildenv.2010.12.017 |
0.377 |
|
2010 |
Braun J, Cho YK, Li H. Editorial: Expanding BIM to Meet the Grand Challenges in Buildings—What is Needed? Hvac&R Research. 16: 543-544. DOI: 10.1080/10789669.2010.10390920 |
0.43 |
|
2010 |
Yang H, Li H. A Generic Rating-Data-Based (GRDB)DX Coils Modeling Method Hvac&R Research. 16: 331-353. DOI: 10.1080/10789669.2010.10390908 |
0.337 |
|
2009 |
Li H, Braun JE. Virtual refrigerant pressure sensors for use in monitoring and fault diagnosis of vapor-compression equipment Hvac and R Research. 15: 597-616. DOI: 10.1080/10789669.2009.10390853 |
0.47 |
|
2009 |
Li H, Braun JE. Decoupling features for diagnosis of reversing and check valve faults in heat pumps International Journal of Refrigeration. 32: 316-326. DOI: 10.1016/J.Ijrefrig.2008.05.005 |
0.532 |
|
2008 |
Li H, Braun JE. A method for modeling adjustable throat-area expansion valves using manufacturer's rating data Hvac and R Research. 14: 581-595. DOI: 10.1080/10789669.2008.10391027 |
0.487 |
|
2007 |
Li H, Braun JE. A methodology for diagnosing multiple simultaneous faults in vapor-compression air conditioners Hvac and R Research. 13: 369-395. DOI: 10.1080/10789669.2007.10390959 |
0.545 |
|
2007 |
Li H, Braun JE. An overall performance index for characterizing the economic impact of faults in direct expansion cooling equipment International Journal of Refrigeration. 30: 299-310. DOI: 10.1016/J.Ijrefrig.2006.07.026 |
0.539 |
|
2007 |
Li H, Braun JE. Decoupling features and virtual sensors for diagnosis of faults in vapor compression air conditioners International Journal of Refrigeration. 30: 546-564. DOI: 10.1016/J.Ijrefrig.2006.07.024 |
0.547 |
|
Show low-probability matches. |