Year |
Citation |
Score |
2014 |
Yan X, Sokol E, Li X, Li G, Xu S, Cooks RG. On-line reaction monitoring and mechanistic studies by mass spectrometry: Negishi cross-coupling, hydrogenolysis, and reductive amination. Angewandte Chemie (International Ed. in English). 53: 5931-5. PMID 24753222 DOI: 10.1002/Anie.201310493 |
0.609 |
|
2013 |
Li G, Li X, Ouyang Z, Cooks RG. Carbon-carbon bond activation in saturated hydrocarbons by field-assisted nitrogen fixation. Angewandte Chemie (International Ed. in English). 52: 1040-3. PMID 23184738 DOI: 10.1002/Anie.201207997 |
0.465 |
|
2012 |
Cyriac J, Wleklinski M, Li G, Gao L, Cooks RG. In situ Raman spectroscopy of surfaces modified by ion soft landing. The Analyst. 137: 1363-9. PMID 22318214 DOI: 10.1039/C2An16163J |
0.699 |
|
2011 |
Huang G, Li G, Cooks RG. Induced nanoelectrospray ionization for matrix-tolerant and high-throughput mass spectrometry. Angewandte Chemie (International Ed. in English). 50: 9907-10. PMID 21898729 DOI: 10.1002/Anie.201103687 |
0.64 |
|
2011 |
Cyriac J, Li G, Cooks RG. Vibrational spectroscopy and mass spectrometry for characterization of soft landed polyatomic molecules. Analytical Chemistry. 83: 5114-21. PMID 21634371 DOI: 10.1021/Ac200118F |
0.698 |
|
2011 |
Huang G, Li G, Ducan J, Ouyang Z, Cooks RG. Synchronized inductive desorption electrospray ionization mass spectrometry. Angewandte Chemie (International Ed. in English). 50: 2503-6. PMID 21370325 DOI: 10.1002/Anie.201007819 |
0.662 |
|
2011 |
Li G, Cyriac J, Gao L, Graham Cooks R. Molecular ion yield enhancement in static secondary ion mass spectrometry by soft landing of protonated water clusters Surface and Interface Analysis. 43: 498-501. DOI: 10.1002/Sia.3161 |
0.674 |
|
2010 |
Gao L, Li G, Cooks RG. Axial CID and high pressure resonance CID in a miniature ion trap mass spectrometer using a discontinuous atmospheric pressure interface. Journal of the American Society For Mass Spectrometry. 21: 209-14. PMID 19892569 DOI: 10.1016/J.Jasms.2009.10.005 |
0.504 |
|
2010 |
Gao L, Li G, Cyriac J, Nie Z, Cooks RG. Imaging of surface charge and the mechanism of desorption electrospray ionization mass spectrometry Journal of Physical Chemistry C. 114: 5331-5337. DOI: 10.1021/Jp904960T |
0.648 |
|
2009 |
Nie Z, Li G, Goodwin MP, Gao L, Cyriac J, Cooks RG. In situ SIMS analysis and reactions of surfaces prepared by soft landing of mass-selected cations and anions using an ion trap mass spectrometer. Journal of the American Society For Mass Spectrometry. 20: 949-56. PMID 19318277 DOI: 10.1016/J.Jasms.2009.02.019 |
0.715 |
|
2009 |
Gao L, Li G, Nie Z, Duncan J, Ouyang Z, Cooks RG. Characterization of a discontinuous atmospheric pressure interface. Multiple ion introduction pulses for improved performance International Journal of Mass Spectrometry. 283: 30-34. DOI: 10.1016/J.Ijms.2009.01.004 |
0.625 |
|
Show low-probability matches. |