Year |
Citation |
Score |
2021 |
Stangherlin A, Day J, O'Neill J. Inductively Coupled Plasma Mass Spectrometry for Elemental Analysis in Circadian Biology. Methods in Molecular Biology (Clifton, N.J.). 2130: 19-27. PMID 33284433 DOI: 10.1007/978-1-0716-0381-9_2 |
0.445 |
|
2003 |
Galy A, Pomiès C, Day JA, Pokrovsky OS, Schott J. High precision measurement of germanium isotope ratio variations by multiple collector-inductively coupled plasma mass spectrometry Journal of Analytical Atomic Spectrometry. 18: 115-119. DOI: 10.1039/b210233a |
0.367 |
|
2002 |
Day JA, Montes-Bayón M, Vonderheide AP, Caruso JA. A study of method robustness for arsenic speciation in drinking water samples by anion exchange HPLC-ICP-MS. Analytical and Bioanalytical Chemistry. 373: 664-8. PMID 12185580 DOI: 10.1007/S00216-002-1384-X |
0.608 |
|
2002 |
Day JA, Kannamkumarath SS, Yanes EG, Montes-Bayón M, Caruso JA. Chiral speciation of Marfey's derivatized DL-selenomethionine using capillary electrophoresis with UV and ICP-MS detection Journal of Analytical Atomic Spectrometry. 17: 27-31. DOI: 10.1039/B104679A |
0.719 |
|
2000 |
Ackley KL, Day JA, Caruso JA. Separation of metalloporphyrins by capillary electrophoresis with UV detection and inductively coupled plasma mass spectrometric detection. Journal of Chromatography. A. 888: 293-8. PMID 10949495 DOI: 10.1016/S0021-9673(00)00516-1 |
0.692 |
|
2000 |
B'Hymer C, Day JA, Caruso JA. Evaluation of a Microconcentric Nebulizer and Its Suction Effect in a Capillary Electrophoresis Interface with Inductively Coupled Plasma Mass Spectrometry Applied Spectroscopy. 54: 1040-1046. DOI: 10.1366/0003702001950544 |
0.736 |
|
2000 |
Day JA, Caruso JA, Sabine Becker J, Dietze HJ. Application of capillary electrophoresis interfaced to double focusing sector field ICP-MS for nuclide abundance determination of lanthanides produced via spallation reactions in an irradiated tantalum target Journal of Analytical Atomic Spectrometry. 15: 1343-1348. DOI: 10.1039/B002617O |
0.672 |
|
2000 |
Day JA, Sutton KL, Soman RS, Caruso JA. A comparison of capillary electrophoresis using indirect UV absorbance and ICP-MS detection with a self-aspirating nebulizer interface Analyst. 125: 819-823. DOI: 10.1039/A910268J |
0.692 |
|
2000 |
B'Hymer C, Day JA, Caruso JA. Evaluation of a microconcentric nebulizer and its suction effect in a capillary electrophoresis interface with inductively coupled plasma mass spectrometry Applied Spectroscopy. 54: 1040-1046. |
0.726 |
|
1999 |
Ackley KL, Day JA, Sutton KL, Caruso JA. Investigation of problems associated with the determination of iodine in glacial acetic acid samples using flow injection analysis-inductively coupled plasma-mass spectrometry† Analytical Communications. 36: 295-298. DOI: 10.1039/A904296B |
0.701 |
|
1999 |
Ackley KL, Day JA, Sutton KL, Caruso JA. Investigation of problems associated with the determination of iodine in glacial acetic acid samples using flow injection analysis-inductively coupled plasma-mass spectrometry Analytical Communications. 36: 295-298. |
0.731 |
|
Show low-probability matches. |