Michael D. Eggen, Ph.D. - Publications

Affiliations: 
2009 Biomedical Engineering University of Minnesota, Twin Cities, Minneapolis, MN 
Area:
Biomedical

29 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2020 Holm MA, Vatterott PJ, Eggen MD, Iaizzo PA. Multimodal imaging employed during extraction of pacing or defibrillator leads from perfusion-fixed human hearts. Heartrhythm Case Reports. 6: 918-921. PMID 33365239 DOI: 10.1016/J.Hrcr.2020.08.025  0.662
2018 Vatterott PJ, Eggen MD, Mattson AR, Omdahl PK, Hilpisch KE, Iaizzo PA. Retrieval of a chronically implanted leadless pacemaker within an isolated heart using direct visualization. Heartrhythm Case Reports. 4: 167-169. PMID 29915709 DOI: 10.1016/J.Hrcr.2017.11.014  0.544
2016 Mattson A, Eggen M, Iaizzo P. 216-04: A Novel Bench-Top Isolated Atrial Preparation for Testing Atrial Pacing and Ablation Technologies Ep Europace. 18: i142-i142. DOI: 10.1093/Europace/18.Suppl_1.I142A  0.526
2016 Mattson A, Grubac V, Eggen M, Iaizzo P. ACUTE PERFORATION PROPERTIES OF THE RIGHT ATRIAL APPENDAGE Journal of the American College of Cardiology. 67: 784. DOI: 10.1016/S0735-1097(16)30785-9  0.412
2016 Mattson AR, Grubac V, Eggen MD, Iaizzo PA. Acute Perforation Properties of the Right Atrial Appendage1 Journal of Medical Devices. 10. DOI: 10.1016/S0735-1097(16)30785-9  0.525
2015 Yang Z, Eggen MD, Marquard KR, Asleson AJ, McVenes RD, Iaizzo PA. Direct visualization of an atrial transseptal left ventricular endocardial lead implantation within an isolated heart. Heartrhythm Case Reports. 1: 107-109. PMID 28507900 DOI: 10.1016/J.Hrcr.2015.01.001  0.629
2015 Omdahl P, Eggen MD, Bonner MD, Wika K, Iaizzo AP. Right Ventricular Anatomy Can Accommodate Multiple Transcatheter Pacemakers. Pacing and Clinical Electrophysiology : Pace. PMID 26710918 DOI: 10.1111/Pace.12804  0.516
2015 Bonner M, Eggen M, Haddad T, Sheldon T, Williams E. Early Performance and Safety of the Micra Transcatheter Pacemaker in Pigs. Pacing and Clinical Electrophysiology : Pace. PMID 26183288 DOI: 10.1111/Pace.12694  0.315
2015 Eggen MD, Grubac V, Bonner MD. Design and Evaluation of a Novel Fixation Mechanism for a Transcatheter Pacemaker. Ieee Transactions On Bio-Medical Engineering. 62: 2316-23. PMID 26111389 DOI: 10.1109/Tbme.2015.2449320  0.323
2015 Yang Z, Eggen MD, Marquard KR, Asleson AJ, McVenes RD, Iaizzo PA. Direct visualization of an atrial transseptal left ventricular endocardial lead implantation within an isolated heart Heartrhythm Case Reports. 1: 107-109. DOI: 10.1016/j.hrcr.2015.01.001  0.585
2015 Bateman MG, Eggen MD, Spencer JH, Iles TL, Iaizzo PA. The use of isolated heart models and anatomical specimens as means to enhance the design and testing of cardiac devices Handbook of Cardiac Anatomy, Physiology, and Devices, Third Edition. 751-764. DOI: 10.1007/978-3-319-19464-6_41  0.835
2015 Laske TG, Dopp AL, Eggen MD, Iaizzo PA. Pacing and defibrillation Handbook of Cardiac Anatomy, Physiology, and Devices, Third Edition. 543-575. DOI: 10.1007/978-3-319-19464-6_30  0.739
2015 Eggen MD, Swingen CM. Cardiovascular magnetic resonance imaging and MR-conditional cardiac devices Handbook of Cardiac Anatomy, Physiology, and Devices, Third Edition. 411-435. DOI: 10.1007/978-3-319-19464-6_24  0.474
2014 Eggen MD, Bonner MD, Williams ER, Iaizzo PA. Multimodal imaging of a transcatheter pacemaker implantation within a reanimated human heart. Heart Rhythm : the Official Journal of the Heart Rhythm Society. 11: 2331-2. PMID 24732365 DOI: 10.1016/J.Hrthm.2014.03.052  0.627
2013 Spencer JH, Quill JL, Bateman MG, Eggen MD, Howard SA, Goff RP, Howard BT, Quallich SG, Iaizzo PA. The benefits of the Atlas of Human Cardiac Anatomy website for the design of cardiac devices. Expert Review of Medical Devices. 10: 729-34. PMID 24195457 DOI: 10.1586/17434440.2013.843449  0.758
2013 Howard SA, Quill JL, Eggen MD, Swingen CM, Iaizzo PA. Novel imaging of atrial septal defects in isolated human hearts. Journal of Cardiovascular Translational Research. 6: 218-20. PMID 23413124 DOI: 10.1007/S12265-013-9451-6  0.805
2013 Bonner M, Eggen M, Depalo J, Sheldon T, Williams E. Assessment of leadless pacemaker performance European Heart Journal. 34: 1918-1918. DOI: 10.1093/Eurheartj/Eht308.1918  0.321
2012 Biffi M, Foerster L, Eastman W, Eggen M, Grenz NA, Sommer J, De Santo T, Haddad T, Varbaro A, Yang Z. Effect of bipolar electrode spacing on phrenic nerve stimulation and left ventricular pacing thresholds: an acute canine study. Circulation. Arrhythmia and Electrophysiology. 5: 815-20. PMID 22787012 DOI: 10.1161/Circep.112.971317  0.387
2012 Liu C, Eggen MD, Swingen CM, Iaizzo PA, He B. Noninvasive mapping of transmural potentials during activation in swine hearts from body surface electrocardiograms. Ieee Transactions On Medical Imaging. 31: 1777-85. PMID 22692900 DOI: 10.1109/Tmi.2012.2202914  0.606
2012 Eggen MD, Swingen CM, Iaizzo PA. Ex vivo diffusion tensor MRI of human hearts: relative effects of specimen decomposition. Magnetic Resonance in Medicine. 67: 1703-9. PMID 22114027 DOI: 10.1002/Mrm.23194  0.585
2012 Rolfes CD, Quill JL, Bateman MG, Hill AJ, Eggen MD, Iaizzo PA. Using the Atlas of Human Cardiac Anatomy to aid in the Design of Cardiac Devices Journal of Medical Devices. 6. DOI: 10.1115/1.4026752  0.734
2011 Lai D, Liu C, Eggen MD, Iaizzo PA, He B. Localization of endocardial ectopic activity by means of noninvasive endocardial surface current density reconstruction. Physics in Medicine and Biology. 56: 4161-76. PMID 21693786 DOI: 10.1088/0031-9155/56/13/027  0.531
2011 Eggen M, Bateman M, Iaizzo PA. Methods to Prepare Perfusion Fixed Cardiac Specimens for Multimodal Imaging: The Use of Formalin and Agar Gels Journal of Medical Devices. 5. DOI: 10.1115/1.3591396  0.778
2010 Lai D, Liu C, Eggen MD, Iaizzo PA, He B. Equivalent moving dipole localization of cardiac ectopic activity in a swine model during pacing. Ieee Transactions On Information Technology in Biomedicine : a Publication of the Ieee Engineering in Medicine and Biology Society. 14: 1318-26. PMID 20515710 DOI: 10.1109/TITB.2010.2051448  0.577
2010 Eggen MD, Bateman MG, Rolfes CD, Howard SA, Swingen CM, Iaizzo PA. MRI assessment of pacing induced ventricular dyssynchrony in an isolated human heart. Journal of Magnetic Resonance Imaging : Jmri. 31: 466-9. PMID 20099368 DOI: 10.1002/Jmri.22050  0.791
2010 Eggen MD, Bateman MG, Rolfes CD, Howard SA, Swingen CM, Iaizzo PA. Assessment of Cardiac Fiber Orientation, Function, and Morphology in a Swine Model of Dilated Cardiomyopathy Using MRI Journal of Cardiac Failure. 16: S26. DOI: 10.1016/J.Cardfail.2010.06.086  0.756
2009 Lai D, Liu C, Eggen MD, Iaizzo PA, He B. Cardiac source localization by means of a single moving dipole solution during endocardial pacing in an animal model. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2009: 1778-80. PMID 19964556 DOI: 10.1109/IEMBS.2009.5334014  0.548
2009 Eggen M, Swingen C, Matta P, Bateman M, Rolfes C, Quill J, Richardson E, Howard S, Iaizzo P. Design of a Novel Perfusion System to Perform MR Imaging of an Isolated Beating Heart Journal of Medical Devices. 3. DOI: 10.1115/1.3147496  0.757
2009 Eggen MD, Swingen CM, Iaizzo PA. Analysis of fiber orientation in normal and failing human hearts using diffusion tensor MRI Proceedings - 2009 Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Isbi 2009. 642-645. DOI: 10.1109/ISBI.2009.5193129  0.661
Show low-probability matches.