Year |
Citation |
Score |
2018 |
Khater H, Brereton S, Dauffy L, Hall J, Hansen L, Kim S, Pohl B, Sitaraman S, Verbeke J, Young M. Simulation of the Post-Shot Radiation Environment in the National Ignition Facility Fusion Science and Technology. 74: 387-405. DOI: 10.1080/15361055.2018.1471961 |
0.467 |
|
2018 |
Ratkiewicz A, Hopkins LB, Bleuel DL, Cassata WS, Cerjan C, Dauffy L, London R, Meeker D, Velsko CA, Yeamans CB. Activation of enriched environmental xenon by 14-MeV neutrons Journal of Radioanalytical and Nuclear Chemistry. 317: 169-175. DOI: 10.1007/S10967-018-5911-4 |
0.327 |
|
2013 |
Khater H, Brereton S, Dauffy L, Hall J, Hansen L, Kim S, Kohut T, Pohl B, Sitaraman S, Verbeke J, Young M. Analysis of decay dose rates and dose management in the National Ignition Facility. Health Physics. 104: 580-8. PMID 23629063 DOI: 10.1097/Hp.0B013E31828D0134 |
0.494 |
|
2012 |
Khan SF, Bell PM, Bradley DK, Burns SR, Celeste JR, Dauffy LS, Eckart MJ, Gerhard MA, Hagmann C, Headley DI, Holder JP, Izumi N, Jones MC, Kellogg JW, Khater HY, et al. Measuring x-ray burn history with the Streaked Polar Instrumentation for Diagnosing Energetic Radiation (SPIDER) at the National Ignition Facility (NIF) Proceedings of Spie - the International Society For Optical Engineering. 8505. DOI: 10.1117/12.930032 |
0.34 |
|
2011 |
Verbeke J, Young M, Brereton S, Dauffy L, Hall J, Hansen L, Khater H, Kim S, Pohl B, Sitaraman S. Planning Tools for Estimating Radiation Exposure at the National Ignition Facility Fusion Science and Technology. 60: 595-599. DOI: 10.13182/Fst10-196 |
0.437 |
|
2011 |
Sitaraman S, Brereton S, Dauffy L, Hall J, Hansen L, Khater H, Kim S, Pohl B, Verbeke J, Young M. Post-Shot Radiation Environment Following Low-Yield Shots inside the National Ignition Facility Fusion Science and Technology. 60: 760-764. DOI: 10.13182/Fst10-192 |
0.371 |
|
2010 |
Sitaraman S, Dauffy L, Khater H, Brereton S. Neutron activation of NIF Final Optics Assemblies Journal of Physics: Conference Series. 244. DOI: 10.1088/1742-6596/244/3/032025 |
0.427 |
|
2009 |
Dauffy LS, Khater HY, Sitaraman S, Brereton SJ. Activation analysis of the final optics assemblies at the national ignition facility Fusion Science and Technology. 56: 736-740. DOI: 10.13182/Fst18-P1.38 |
0.465 |
|
2009 |
Khater H, Dauffy L, Sitaraman S, Brereton S. Evaluation of Prompt Dose Environment in the National Ignition Facility during D-D and THD Shots Fusion Science and Technology. 56: 697-701. DOI: 10.13182/Fst09-697 |
0.429 |
|
2008 |
Ali ZA, Glebov VY, Cruz M, Duffy T, Stoeckl C, Roberts S, Sangster TC, Tommasini R, Throop A, Moran M, Dauffy L, Horsefield C. Tests and calibration of NIF neutron time of flight detectors. The Review of Scientific Instruments. 79: 10E527. PMID 19044508 DOI: 10.1063/1.2969289 |
0.336 |
|
2005 |
Dauffy LS, Braby LA, Berner BM. Dosimetry of the Au198 source used in interstitial brachytherapy. Medical Physics. 32: 1579-1588. PMID 28513959 DOI: 10.1118/1.1924347 |
0.608 |
|
2005 |
Dauffy LS, Braby LA, Berner BM. Dosimetry of the 198Au source used in interstitial brachytherapy. Medical Physics. 32: 1579-88. PMID 16013717 DOI: 10.1118/1.1924347 |
0.582 |
|
2004 |
Dauffy LS. Dosimetric characteristics and a standard for the 198Au seed used in interstitial brachytherapy Medical Physics. 31: 683-683. DOI: 10.1118/1.1644511 |
0.599 |
|
2003 |
Descalle MA, Hartmann Siantar CL, Dauffy L, Nigg DW, Wemple CA, Yuan A, DeNardo GL. Application of MINERVA Monte Carlo simulations to targeted radionuclide therapy. Cancer Biotherapy & Radiopharmaceuticals. 18: 71-9. PMID 12667310 DOI: 10.1089/108497803321269340 |
0.328 |
|
Show low-probability matches. |