Year |
Citation |
Score |
2008 |
Dockery CR, Blew MJ, Goode SR. Visualizing the solute vaporization interference in flame atomic absorption spectroscopy Journal of Chemical Education. 85: 854-858. DOI: 10.1021/Ed085P854 |
0.712 |
|
2006 |
Pender J, Pearman B, Scaffidi J, Goode SR, Angel SM. Laser-induced breakdown spectroscopy using sequential laser pulses Laser Induced Breakdown Spectroscopy (Libs): Fundamentals and Applications. 516-538. DOI: 10.1017/CBO9780511541261.016 |
0.76 |
|
2005 |
Dockery CR, Pender JE, Goode SR. Speciation of chromium via laser-induced breakdown spectroscopy of ion exchange polymer membranes. Applied Spectroscopy. 59: 252-7. PMID 15720767 DOI: 10.1366/0003702053085061 |
0.68 |
|
2004 |
Meruva NK, Metz LA, Goode SR, Morgan SL. UV laser pyrolysis fast gas chromatography/time-of-flight mass spectrometry for rapid characterization of synthetic polymers: Instrument development Journal of Analytical and Applied Pyrolysis. 71: 313-325. DOI: 10.1016/S0165-2370(03)00092-5 |
0.735 |
|
2004 |
Metz LA, Meruva NK, Morgan SL, Goode SR. UV laser pyrolysis fast gas chromatography/time-of-flight mass spectrometry for rapid characterization of synthetic polymers: Optimization of instrumental parameters Journal of Analytical and Applied Pyrolysis. 71: 327-341. DOI: 10.1016/S0165-2370(03)00091-3 |
0.737 |
|
2003 |
Dockery CR, Goode SR. Laser-induced breakdown spectroscopy for the detection of gunshot residues on the hands of a shooter. Applied Optics. 42: 6153-8. PMID 14594078 DOI: 10.1364/Ao.42.006153 |
0.74 |
|
2003 |
Scaffidi J, Pender J, Pearman W, Goode SR, Colston BW, Carter JC, Angel SM. Dual-pulse laser-induced breakdown spectroscopy with combinations of femtosecond and nanosecond laser pulses. Applied Optics. 42: 6099-106. PMID 14594072 DOI: 10.1364/Ao.42.006099 |
0.747 |
|
2003 |
Goode SR, Metz LA. Emission spectroscopy in the undergraduate laboratory Journal of Chemical Education. 80: 1455-1459. DOI: 10.1021/Ed080P1455 |
0.687 |
|
2001 |
Eland KL, Stratis DN, Gold DM, Goode SR, Angel SM. Energy dependence of emission intensity and temperature in a LIBS plasma using femtosecond excitation Applied Spectroscopy. 55: 286-291. DOI: 10.1366/0003702011951902 |
0.305 |
|
2000 |
Goode SR, Morgan SL, Hoskins R, Oxsher A. Identifying alloys by laser-induced breakdown spectroscopy with a time-resolved high resolution echelle spectrometer Journal of Analytical Atomic Spectrometry. 15: 1133-1138. DOI: 10.1039/B002190N |
0.596 |
|
1974 |
Montaser A, Goode SR, Crouch SR. Graphite braid atomizer for atomic absorption and atomic fluorescence spectrometry. Analytical Chemistry. 46: 599-601. PMID 4819086 DOI: 10.1021/Ac60340A013 |
0.633 |
|
1974 |
Goode SR, Crouch SR. Practical method for the determination of stray radiant energy in atomic absorption spectrometers Analytical Chemistry. 46: 181-182. DOI: 10.1021/Ac60337A028 |
0.523 |
|
1973 |
Goode SR, Montaser A, Crouch SR. Optimization of instrumental parameters in an automated nonflame atomic fluorescence spectrometer Applied Spectroscopy. 27: 355-361. DOI: 10.1366/000370273774333407 |
0.644 |
|
Show low-probability matches. |