Year |
Citation |
Score |
2019 |
Caldwell R, Street MG, Sharma R, Takmakov P, Baker B, Rieth L. Characterization of Parylene-C degradation mechanisms: In vitro reactive accelerated aging model compared to multiyear in vivo implantation. Biomaterials. 232: 119731. PMID 31918225 DOI: 10.1016/J.Biomaterials.2019.119731 |
0.301 |
|
2018 |
Park H, Takmakov P, Lee H. Electrochemical Evaluations of Fractal Microelectrodes for Energy Efficient Neurostimulation. Scientific Reports. 8: 4375. PMID 29531230 DOI: 10.1038/S41598-018-22545-W |
0.423 |
|
2017 |
Caldwell R, Sharma R, Takmakov P, Street MG, Solzbacher F, Tathireddy P, Rieth L. Neural electrode resilience against dielectric damage may be improved by use of highly doped silicon as a conductive material. Journal of Neuroscience Methods. PMID 29017900 DOI: 10.1016/J.Jneumeth.2017.10.002 |
0.352 |
|
2016 |
Kumsa D, Hudak EM, Montague FW, Kelley SC, Untereker DF, Hahn BP, Condit C, Cholette M, Lee H, Bardot D, Takmakov P. Electrical neurostimulation with imbalanced waveform mitigates dissolution of platinum electrodes. Journal of Neural Engineering. 13: 054001. PMID 27650936 DOI: 10.1088/1741-2560/13/5/054001 |
0.343 |
|
2016 |
Fox ME, Mikhailova MA, Bass CE, Takmakov P, Gainetdinov RR, Budygin EA, Wightman RM. Cross-hemispheric dopamine projections have functional significance. Proceedings of the National Academy of Sciences of the United States of America. PMID 27298371 DOI: 10.1073/Pnas.1603629113 |
0.748 |
|
2015 |
Takmakov P, Ruda K, Scott Phillips K, Isayeva IS, Krauthamer V, Welle CG. Rapid evaluation of the durability of cortical neural implants using accelerated aging with reactive oxygen species. Journal of Neural Engineering. 12: 026003. PMID 25627426 DOI: 10.1088/1741-2560/12/2/026003 |
0.304 |
|
2013 |
Bucher ES, Brooks K, Verber MD, Keithley RB, Owesson-White C, Carroll S, Takmakov P, McKinney CJ, Wightman RM. Flexible software platform for fast-scan cyclic voltammetry data acquisition and analysis. Analytical Chemistry. 85: 10344-53. PMID 24083898 DOI: 10.1021/Ac402263X |
0.65 |
|
2012 |
Hashemi P, Dankoski EC, Lama R, Wood KM, Takmakov P, Wightman RM. Brain dopamine and serotonin differ in regulation and its consequences. Proceedings of the National Academy of Sciences of the United States of America. 109: 11510-5. PMID 22778401 DOI: 10.1073/Pnas.1201547109 |
0.729 |
|
2011 |
Hashemi P, Walsh PL, Guillot TS, Gras-Najjar J, Takmakov P, Crews FT, Wightman RM. Chronically Implanted, Nafion-Coated Ag/AgCl Reference Electrodes for Neurochemical Applications. Acs Chemical Neuroscience. 2: 658-666. PMID 22125666 DOI: 10.1021/Cn2000684 |
0.748 |
|
2011 |
Park J, Takmakov P, Wightman RM. In vivo comparison of norepinephrine and dopamine release in rat brain by simultaneous measurements with fast-scan cyclic voltammetry. Journal of Neurochemistry. 119: 932-44. PMID 21933188 DOI: 10.1111/J.1471-4159.2011.07494.X |
0.589 |
|
2011 |
Takmakov P, McKinney CJ, Carelli RM, Wightman RM. Instrumentation for fast-scan cyclic voltammetry combined with electrophysiology for behavioral experiments in freely moving animals. The Review of Scientific Instruments. 82: 074302. PMID 21806203 DOI: 10.1063/1.3610651 |
0.616 |
|
2011 |
Keithley RB, Takmakov P, Bucher ES, Belle AM, Owesson-White CA, Park J, Wightman RM. Higher sensitivity dopamine measurements with faster-scan cyclic voltammetry. Analytical Chemistry. 83: 3563-71. PMID 21473572 DOI: 10.1021/Ac200143V |
0.617 |
|
2010 |
Takmakov P, Zachek MK, Keithley RB, Bucher ES, McCarty GS, Wightman RM. Characterization of local pH changes in brain using fast-scan cyclic voltammetry with carbon microelectrodes. Analytical Chemistry. 82: 9892-900. PMID 21047096 DOI: 10.1021/Ac102399N |
0.714 |
|
2010 |
Zachek MK, Park J, Takmakov P, Wightman RM, McCarty GS. Microfabricated FSCV-compatible microelectrode array for real-time monitoring of heterogeneous dopamine release. The Analyst. 135: 1556-63. PMID 20464031 DOI: 10.1039/C0An00114G |
0.631 |
|
2010 |
Takmakov P, Zachek MK, Keithley RB, Walsh PL, Donley C, McCarty GS, Wightman RM. Carbon microelectrodes with a renewable surface. Analytical Chemistry. 82: 2020-8. PMID 20146453 DOI: 10.1021/Ac902753X |
0.763 |
|
2010 |
Zachek MK, Takmakov P, Park J, Wightman RM, McCarty GS. Simultaneous monitoring of dopamine concentration at spatially different brain locations in vivo. Biosensors & Bioelectronics. 25: 1179-85. PMID 19896822 DOI: 10.1016/J.Bios.2009.10.008 |
0.6 |
|
2009 |
Zachek MK, Takmakov P, Moody B, Wightman RM, McCarty GS. Simultaneous decoupled detection of dopamine and oxygen using pyrolyzed carbon microarrays and fast-scan cyclic voltammetry. Analytical Chemistry. 81: 6258-65. PMID 19552423 DOI: 10.1021/Ac900790M |
0.627 |
|
2006 |
Takmakov P, Vlassiouk I, Smirnov S. Hydrothermally shrunk alumina nanopores and their application to DNA sensing. The Analyst. 131: 1248-53. PMID 17066194 DOI: 10.1039/B608084G |
0.304 |
|
2005 |
Vlassiouk I, Takmakov P, Smirnov S. Sensing DNA hybridization via ionic conductance through a nanoporous electrode. Langmuir : the Acs Journal of Surfaces and Colloids. 21: 4776-8. PMID 15896007 DOI: 10.1021/La0471644 |
0.34 |
|
Show low-probability matches. |