Year |
Citation |
Score |
2019 |
Hesketh PJ, Stetter J, Zeng X. Chemical Sensors for Today and Tomorrow The Electrochemical Society Interface. 28: 45-46. DOI: 10.1149/2.F04193If |
0.447 |
|
2018 |
Struk D, Shirke A, Mahdavifar A, Hesketh PJ, Stetter JR. Investigating time-resolved response of micro thermal conductivity sensor under various modes of operation Sensors and Actuators B: Chemical. 254: 771-777. DOI: 10.1016/J.Snb.2017.07.142 |
0.356 |
|
2017 |
Lotfi A, Mahdavifar A, Struk D, Stetter JR, Navaei M, Hesketh P. Ultimate Sensitivity of Physical Sensor for Ammonia Gas Detection Exploiting Full Differential 3-Omega Technique Ecs Transactions. 80: 1571-1578. DOI: 10.1149/08010.1571ECST |
0.387 |
|
2016 |
Arriaga RI, Findlay M, Hesketh PJ, Stetter JR. Ubiquitous Wearable Electrochemical Sensors The Electrochemical Society Interface. 25: 69-72. DOI: 10.1149/2.F05164If |
0.455 |
|
2015 |
Mahdavifar A, Navaei M, Hesketh PJ, Findlay M, Stetter JR, Hunter GW. Transient thermal response of micro-thermal conductivity detector (µTCD) for the identification of gas mixtures: An ultra-fast and low power method Microsystems & Nanoengineering. 1. DOI: 10.1038/Micronano.2015.25 |
0.382 |
|
2014 |
Wang Z, Guo M, Baker GA, Stetter JR, Lin L, Mason AJ, Zeng X. Methane-oxygen electrochemical coupling in an ionic liquid: a robust sensor for simultaneous quantification. The Analyst. 139: 5140-7. PMID 25093213 DOI: 10.1039/C4An00839A |
0.445 |
|
2014 |
Mahdavifar A, Aguilar R, Peng Z, Hesketh PJ, Findlay M, Stetter JR, Hunter GW. Simulation and Fabrication of an Ultra-Low Power Miniature Microbridge Thermal Conductivity Gas Sensor Journal of the Electrochemical Society. 161: B55-B61. DOI: 10.1149/2.032404Jes |
0.409 |
|
2014 |
Carter MT, Stetter JR, Findlay MW, Patel V. Rational design of amperometric gas sensors with ionic liquid electrolytes Ecs Transactions. 64: 95-103. DOI: 10.1149/06401.0095ecst |
0.436 |
|
2014 |
Stetter JR, Carter MT, Findlay MW, Stetter E, Patel V, Ploense L, Shirke AG, O'Toole G, Gaerlan D. Printed gas sensors for the trillion sensor universe Technical Proceedings of the 2014 Nsti Nanotechnology Conference and Expo, Nsti-Nanotech 2014. 3: 71-74. |
0.433 |
|
2013 |
Carter MT, Stetter JR, Findlay MW, Patel V. Amperometric gas sensors with ionic liquid electrolytes Ecs Transactions. 58: 7-18. DOI: 10.1149/05834.0007ecst |
0.465 |
|
2012 |
Chang SC, Stetter JR, Cha CS. Amperometric gas sensors. Talanta. 40: 461-77. PMID 18965651 DOI: 10.1016/0039-9140(93)80002-9 |
0.421 |
|
2012 |
Hunter GW, Stetter JR, Hesketh PJ, Liu CC. Smart sensor systems Nato Science For Peace and Security Series B: Physics and Biophysics. 205-214. DOI: 10.1149/2.F03104If |
0.419 |
|
2012 |
Carter MT, Stetter JR, Findlay MW, Patel V. Printed amperometric gas sensors Ecs Transactions. 50: 211-220. DOI: 10.1149/05012.0211ecst |
0.489 |
|
2011 |
Wang Z, Lin P, Baker GA, Stetter J, Zeng X. Ionic liquids as electrolytes for the development of a robust amperometric oxygen sensor. Analytical Chemistry. 83: 7066-73. PMID 21848335 DOI: 10.1021/Ac201235W |
0.325 |
|
2010 |
Aguilar R, Peng Z, Hesketh PJ, Stetter JR. An ultra-low power microbridge gas sensor Ecs Transactions. 33: 245-253. DOI: 10.1149/1.3484128 |
0.431 |
|
2010 |
STETTER JR, PENROSE WR, MACLAY GJ, BUTTNER WJ, FINDLAY MW, CAO Z, LUSKUS LJ, MULIK JD. ChemInform Abstract: The Electrochemical Sensor. One Solution for Pollution Cheminform. 24: no-no. DOI: 10.1002/chin.199346334 |
0.389 |
|
2009 |
Korotcenkov G, Han SD, Stetter JR. Review of electrochemical hydrogen sensors. Chemical Reviews. 109: 1402-33. PMID 19222198 DOI: 10.1021/cr800339k |
0.372 |
|
2009 |
Stetter JR. Diversity in sensing with sensor arrays: Hardware/software for artificial senses Ecs Transactions. 19: 261-265. DOI: 10.1149/1.3118560 |
0.434 |
|
2009 |
Ebeling D, Patel V, Findlay M, Stetter J. Electrochemical ozone sensor and instrument with characterization of the electrode and gas flow effects Sensors and Actuators, B: Chemical. 137: 129-133. DOI: 10.1016/J.Snb.2008.10.038 |
0.451 |
|
2008 |
Stetter JR, Li J. Amperometric gas sensors--a review. Chemical Reviews. 108: 352-66. PMID 18201108 DOI: 10.1021/cr0681039 |
0.394 |
|
2008 |
Korotcenkov G, Stetter JR. Comparative study of SnO2- and In2O3- based ozone sensors Ecs Transactions. 6: 29-41. DOI: 10.1149/1.2831341 |
0.365 |
|
2008 |
Ni M, Stetter JR, Buttner WJ. Orthogonal gas sensor arrays with intelligent algorithms for early warning of electrical fires Sensors and Actuators, B: Chemical. 130: 889-899. DOI: 10.1016/j.snb.2007.10.070 |
0.455 |
|
2008 |
Stetter JR, Li J. ChemInform Abstract: Amperometric Gas Sensors - A Review Cheminform. 39. DOI: 10.1002/CHIN.200816274 |
0.388 |
|
2007 |
Mehta M, Hanumanthaiah CS, Betala PA, Zhang H, Roh S, Buttner W, Penrose WR, Stetter JR, Pérez-Luna VH. Detection of proteins and bacteria using an array of feedback capacitance sensors. Biosensors & Bioelectronics. 23: 728-34. PMID 17888647 DOI: 10.1016/J.Bios.2007.08.011 |
0.387 |
|
2007 |
Korotcenkov G, Ivanov M, Blinov I, Stetter JR. Kinetics of indium oxide-based thin film gas sensor response: The role of "redox" and adsorption/desorption processes in gas sensing effects Thin Solid Films. 515: 3987-3996. DOI: 10.1016/j.tsf.2006.09.044 |
0.385 |
|
2007 |
Korotcenkov G, Brinzari V, Stetter JR, Blinov I, Blaja V. The nature of processes controlling the kinetics of indium oxide-based thin film gas sensor response Sensors and Actuators, B: Chemical. 128: 51-63. DOI: 10.1016/j.snb.2007.05.028 |
0.302 |
|
2007 |
Korotcenkov G, Blinov I, Brinzari V, Stetter JR. Effect of air humidity on gas response of SnO2 thin film ozone sensors Sensors and Actuators, B: Chemical. 122: 519-526. DOI: 10.1016/j.snb.2006.06.025 |
0.392 |
|
2007 |
Korotcenkov G, Blinov I, Ivanov M, Stetter JR. Ozone sensors on the base of SnO2 films deposited by spray pyrolysis Sensors and Actuators, B: Chemical. 120: 679-686. DOI: 10.1016/j.snb.2006.03.029 |
0.352 |
|
2006 |
Buttner WJ, Chung GH, Evans L, Hunter G, Stetter JR, Jeong JS, Xu J, Vander Wal R, Wang R. Surface characterization and manipulation of SWCNT for sensor applications Ecs Transactions. 1: 9-15. DOI: 10.1149/1.2218986 |
0.426 |
|
2006 |
Stetter JR, Hesketh PJ, Hunter GW. Sensors: Engineering structures and materials from micro to nano Electrochemical Society Interface. 15: 66-69. |
0.388 |
|
2005 |
Korotcenkov G, Brinzari V, Ivanov M, Blinov I, Stetter J. Processes controlling the rate of in2O3 thin film gas sensor's response Proceedings of the International Semiconductor Conference, Cas. 1: 209-212. DOI: 10.1109/SMICND.2005.1558749 |
0.326 |
|
2005 |
Chao Y, Yao S, Buttner WJ, Stetter JR. Amperometric sensor for selective and stable hydrogen measurement Sensors and Actuators, B: Chemical. 106: 784-790. DOI: 10.1016/j.snb.2004.09.042 |
0.41 |
|
2005 |
Pardo M, Kwong LG, Sberveglieri G, Brubaker K, Schneider JF, Penrose WR, Stetter JR. Data analysis for a hybrid sensor array Sensors and Actuators, B: Chemical. 106: 136-143. DOI: 10.1016/j.snb.2004.05.045 |
0.427 |
|
2004 |
Yao S, Stetter JR. Modification of NASICON Solid Electrolyte for NOx Measurements Journal of the Electrochemical Society. 151. DOI: 10.1149/1.1647577 |
0.441 |
|
2004 |
Star A, Han TR, Joshi V, Stetter JR. Sensing with Nafion Coated Carbon Nanotube Field-Effect Transistors Electroanalysis. 16: 108-112. DOI: 10.1002/Elan.200302925 |
0.319 |
|
2004 |
Roh S, Stetter JR. Amperometric Sensing of NOx with Cyclic Voltammetry. Cheminform. 35. DOI: 10.1002/CHIN.200404015 |
0.355 |
|
2004 |
Chao YT, Buttner WJ, Gupta K, Penrose WR, Stetter JR. Hydrogen amperometric gas sensor: Performance evaluation by sstuf Proceedings - Electrochemical Society. 8: 109-116. |
0.453 |
|
2004 |
Roh SW, Buttner WJ, Stetter JR. Carbon nanotube modified gold (Au) electrode for anodic oxidation of H 2S Proceedings - Electrochemical Society. 8: 133-138. |
0.371 |
|
2003 |
Roh SW, Stetter JR. Gold film amperometric sensors for NO and NO2 Journal of the Electrochemical Society. 150. DOI: 10.1149/1.1616003 |
0.524 |
|
2003 |
Roh SW, Stetter JR. Amperometric sensing of NOx with cyclic voltammetry Journal of the Electrochemical Society. 150. DOI: 10.1149/1.1616002 |
0.442 |
|
2003 |
Stetter JR, Penrose WR, Yao S. Sensors chemical sensors, electrochemical sensors, and ECS Journal of the Electrochemical Society. 150. DOI: 10.1149/1.1539051 |
0.397 |
|
2003 |
Pardo M, Kwong LG, Sberveglieri G, Schneider J, Penrose WR, Stetter JR. Detection of Contraband Food Products with a Hybrid Chemical Sensor System Proceedings of Ieee Sensors. 2: 1073-1076. |
0.421 |
|
2003 |
Stetter JR, Bradley K, Cumings J, Gabriel JC, Gruner G, Star A. Nano-electronic sensors; practical device designs for sensors 2003 Nanotechnology Conference and Trade Show - Nanotech 2003. 3: 313-316. |
0.382 |
|
2003 |
Roh SW, Yao S, Buttner WJ, Stetter JR. Amperometric H2S Sensor with Pd/Au electrode by electrochemical deposition Proceedings of Ieee Sensors. 2: 186-190. |
0.312 |
|
2002 |
Stetter JR, Penrose WR. Understanding Chemical Sensors and Chemical Sensor Arrays (Electronic Noses): Past, Present, and Future Sensors Update. 10: 189-229. DOI: 10.1002/1616-8984(200201)10:1<189::AID-SEUP189>3.0.CO;2-N |
0.421 |
|
2000 |
Bârsan N, Stetter JR, Findlay M, Göpel W. High performance gas sensing of CO: Comparative tests for (SnO2-based) semiconducting and for electrochemical sensors Sensors and Actuators, B: Chemical. 66: 31-33. DOI: 10.1016/S0925-4005(99)00335-4 |
0.45 |
|
2000 |
McEntegart CM, Penrose WR, Strathmann S, Stetter JR. Detection and discrimination of coliform bacteria with gas sensor arrays Sensors and Actuators, B: Chemical. 70: 170-176. DOI: 10.1016/S0925-4005(00)00561-X |
0.407 |
|
2000 |
Stetter JR, Strathmann S, McEntegart C, Decastro M, Penrose WR. New sensor arrays and sampling systems for a modular electronic nose Sensors and Actuators, B: Chemical. 69: 410-419. DOI: 10.1016/S0925-4005(00)00503-7 |
0.452 |
|
1999 |
Bârsan N, Stetter JR, Findlay M, Göpel W. High-Performance Gas Sensing of CO: Comparative Tests for Semiconducting (SnO(2)-Based) and for Amperometric Gas Sensors. Analytical Chemistry. 71: 2512-7. PMID 21662796 DOI: 10.1021/ac981246d |
0.47 |
|
1997 |
Hesketh PJ, Zivanovic S, Ming Y, Pak S, Svojanovsky S, Cunneen J, Caraffini S, Boyd JG, Stetter JR, Lunte SM, Wilson GS. Microfabricated biosensors and microsystems Proceedings of the International Conference On Microelectronics. 1: 63-69. |
0.301 |
|
1995 |
Penrose WR, Pan L, Stetter JR, Ollison WM. Sensitive measurement of ozone using amperometric gas sensors Analytica Chimica Acta. 313: 209-219. DOI: 10.1016/0003-2670(95)00251-T |
0.422 |
|
1993 |
Moyer ES, Findlay MW, Maclay GJ, Stetter JR. preliminary evaluation of an active end-of-service-life indicator for organic vapor cartridge respirators American Industrial Hygiene Association Journal. 54: 417-425. PMID 8213485 DOI: 10.1080/15298669391354900 |
0.414 |
|
1993 |
Stetter JR, Findlay MW, Schroeder KM, Yue C, Penrose WR. Quality classification of grain using a sensor array and pattern recognition Analytica Chimica Acta. 284: 1-11. DOI: 10.1016/0003-2670(93)80001-2 |
0.329 |
|
1992 |
Ballantine DS, Callahan D, Maclay GJ, Stetter JR. An optical waveguide acid vapor sensor Talanta. 39: 1657-1667. DOI: 10.1016/0039-9140(92)80200-W |
0.416 |
|
1992 |
Cao Z, Buttner WJ, Stetter JR. The properties and applications of amperometric gas sensors Electroanalysis. 4: 253-266. DOI: 10.1002/elan.1140040302 |
0.46 |
|
1991 |
Maclay GJ, Yue C, Findlay MW, Stetter JR. A prototype active end-of-service-life indicator for respirator cartridges Applied Occupational and Environmental Hygiene. 6: 677-682. DOI: 10.1080/1047322X.1991.10387960 |
0.385 |
|
1991 |
Keyvani D, Maclay J, Lee S, Stetter J, Cao Z. A planar integrated chlorinated hydrocarbon gas sensor on a silicon substrate Sensors and Actuators: B. Chemical. 5: 199-203. DOI: 10.1016/0925-4005(91)80247-H |
0.434 |
|
1991 |
Cao Z, Stetter JR. A selective solid-state gas sensor for halogenated hydrocarbons Sensors and Actuators: B. Chemical. 5: 109-113. DOI: 10.1016/0925-4005(91)80229-D |
0.502 |
|
1991 |
Vaihinger S, Göpel W, Stetter JR. Detection of halogenated and other hydrocarbons in air: Response functions of catalyst/electrochemical sensor systems Sensors and Actuators: B. Chemical. 4: 337-343. DOI: 10.1016/0925-4005(91)80133-5 |
0.338 |
|
1990 |
Buttner WJ, Maclay GJ, Stetter JR. An integrated amperometric microsensor Sensors and Actuators: B. Chemical. 1: 303-307. DOI: 10.1016/0925-4005(90)80220-T |
0.435 |
|
1990 |
Stetter JR, Findlay MW, Jordan Maclay G, Zhang J, Vaihinger S, Göpel W. Sensor array and catalytic filament for chemical analysis of vapors and mixtures Sensors and Actuators: B. Chemical. 1: 43-47. DOI: 10.1016/0925-4005(90)80169-Z |
0.437 |
|
1990 |
Chang S‐, Stetter JR. Electrochemical NO2 gas sensors: Model and mechanism for the electroreduction of NO2 Electroanalysis. 2: 359-365. DOI: 10.1002/elan.1140020506 |
0.5 |
|
1990 |
Stetter JR, Cao Z. Gas sensor and permeation apparatus for the determination of chlorinated hydrocarbons in water Analytical Chemistry. 62: 182-185. |
0.371 |
|
1989 |
Maclay GJ, Stetter JR, Christesen S. Use of time-dependent chemical sensor signals for selective identification Sensors and Actuators. 20: 277-285. DOI: 10.1016/0250-6874(89)80126-X |
0.36 |
|
1988 |
Maclay GJ, Buttner WJ, Stetter JR. Microfabricated Amperometric Gas Sensors Ieee Transactions On Electron Devices. 35: 793-799. DOI: 10.1109/16.2533 |
0.474 |
|
1987 |
Otagawa T, Stetter JR. A chemical concentration modulation sensor for selective detection of airborne chemicals Sensors and Actuators. 11: 251-264. DOI: 10.1016/0250-6874(87)80004-5 |
0.329 |
|
1987 |
Stetter JR, Zaromb S, Penrose W. 4670405 Sensor array for toxic gas detection Atmospheric Environment (1967). 21: ii. DOI: 10.1016/0004-6981(87)90221-6 |
0.441 |
|
1986 |
Stetter JR, Jurs PC, Rose SL. Detection of hazardous gases and vapors: Pattern recognition analysis of data from an electrochemical sensor array Analytical Chemistry. 58: 860-866. DOI: 10.1021/Ac00295A047 |
0.314 |
|
1985 |
Otagawa T, Zaromb S, Stetter JR. Electrochemical Oxidation of Methane in Nonaqueous Electrolytes at Room Temperature Application to Gas Sensors Journal of the Electrochemical Society. 132: 2951-2957. DOI: 10.1149/1.2113699 |
0.327 |
|
1985 |
Otagawa T, Zaromb S, Stetter JR. A room-temperature electrochemical sensor and instrument for monitoring methane Sensors and Actuators. 8: 65-88. DOI: 10.1016/0250-6874(85)80025-1 |
0.469 |
|
1984 |
Stetter JR, Zaromb S, Findlay MW. Monitoring of electrochemically inactive compounds by amperometric gas sensors Sensors and Actuators. 6: 269-288. DOI: 10.1016/0250-6874(84)85022-2 |
0.444 |
|
1983 |
Stetter JR, Zaromb S. A dynamic coulometric technique for gas analysis Journal of Electroanalytical Chemistry. 148: 271-277. DOI: 10.1016/S0022-0728(83)80402-1 |
0.349 |
|
1978 |
Stetter JR. A surface chemical view of gas detection Journal of Colloid and Interface Science. 65: 432-443. DOI: 10.1016/0021-9797(78)90094-2 |
0.365 |
|
Show low-probability matches. |