42 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2016 Trzcinski P, Weagant S, Karanassios V. Wireless Data Acquisition of Transient Signals for Mobile Spectrometry Applications. Applied Spectroscopy. 70: 905-15. PMID 27006023 DOI: 10.1177/0003702816638304  0.332
2015 German J, Karanassios V. Chromium speciation using large scale plasmas in a lab and towards field deployable speciation by employing a battery-operated microplasma-on-a-chip and optical emission spectrometry Proceedings of Spie. 9482: 948203. DOI: 10.1117/12.2177511  0.401
2015 Weagant S, Dulai G, Li L, Karanassios V. Characterization of rapidly-prototyped, battery-operated, argon-hydrogen microplasma on a hybrid chip for elemental analysis of microsamples by portable optical emission spectrometry Spectrochimica Acta Part B: Atomic Spectroscopy. 106: 75-80. DOI: 10.1016/J.Sab.2015.01.009  0.415
2014 Nguon O, Huang S, Gauthier M, Karanassios V. Microplasmas: from applications to fundamentals Proceedings of Spie. 9101: 910106. DOI: 10.1117/12.2050348  0.308
2014 Li Z, Zhang X, Karanassios V. Verification of the performance of Artificial Neural Networks (ANNs) versus Partial Least Squares (PLS) for spectral interference correction in optical emission spectrometry Proceedings of Spie. 9118: 911812. DOI: 10.1117/12.2050326  0.322
2013 Li Z, Zhang X, Karanassios V. How do artificial neural networks (ANNs) compare to partial least squares (PLS) for spectral interference correction in optical emission spectrometry Proceedings of Spie. 9496. DOI: 10.1117/12.2177516  0.308
2013 Abbaszadeh S, Karim KS, Karanassios V. A microfabricated, low dark current a-Se detector for measurement of microplasma optical emission in the UV for possible use on-site Proceedings of Spie - the International Society For Optical Engineering. 8726. DOI: 10.1117/12.2016229  0.355
2013 Abbaszadeh S, Karim KS, Karanassios V. Measurement of UV from a microplasma by a microfabricated amorphous selenium detector Ieee Transactions On Electron Devices. 60: 880-883. DOI: 10.1109/Ted.2012.2231682  0.333
2013 Badiei HR, Liu C, Karanassios V. Taking part of the lab to the sample: On-site electrodeposition of Pb followed by measurement in a lab using electrothermal, near-torch vaporization sample introduction and inductively coupled plasma-atomic emission spectrometry Microchemical Journal. 108: 131-136. DOI: 10.1016/J.Microc.2012.10.013  0.782
2012 Curtis C, Eshaque B, Badali K, Karanassios V. Rapid prototyping of a microfluidics-based Venturi micropump imprinted on polymeric, postage stamp sized chips Proceedings of Spie. 8366. DOI: 10.1117/12.919562  0.418
2012 Zhang X, Karanassios V. Rapid prototyping of solar-powered, battery-operated, atmospheric-pressure, sugar-cube size microplasma on hybrid, 3D chips for elemental analysis of liquid microsamples using a portable optical emission spectrometer Proceedings of Spie. 8366. DOI: 10.1117/12.919550  0.3
2012 Badiei HR, McEnaney J, Karanassios V. Bringing part of the lab to the field: On-site chromium speciation in seawater by electrodeposition of Cr(III)/Cr(VI) on portable coiled-filament assemblies and measurement in the lab by electrothermal, near-torch vaporization sample introduction and inductively coupled plasma-atomic emission spectrometry Spectrochimica Acta Part B: Atomic Spectroscopy. 78: 42-49. DOI: 10.1016/J.Sab.2012.10.002  0.736
2012 Badiei HR, Lai B, Karanassios V. Micro- and nano-volume samples by electrothermal, near-torch vaporization sample introduction using removable, interchangeable and portable rhenium coiled-filament assemblies and axially-viewed inductively coupled plasma-atomic emission spectrometry Spectrochimica Acta - Part B Atomic Spectroscopy. 77: 19-30. DOI: 10.1016/J.Sab.2012.07.025  0.789
2011 Weagant S, Chen V, Karanassios V. Battery-operated, argon-hydrogen microplasma on hybrid, postage stamp-sized plastic-quartz chips for elemental analysis of liquid microsamples using a portable optical emission spectrometer. Analytical and Bioanalytical Chemistry. 401: 2865-80. PMID 21909664 DOI: 10.1007/S00216-011-5372-X  0.422
2011 Li Z, Huang S, Karanassios V. Further development of artificial neural networks for spectral interference correction in optical emission spectrometry Proceedings of Spie. 8401. DOI: 10.1117/12.884341  0.351
2011 Weagant S, Karanassios V. Battery-operated planar-geometry microplasma on a postage-stamp size chip: some fundamentals Proceedings of Spie. 8024. DOI: 10.1117/12.884329  0.319
2010 Hwang YM, Stathopulos PB, Dimmick K, Yang H, Badiei HR, Tong MS, Rumfeldt JA, Chen P, Karanassios V, Meiering EM. Nonamyloid aggregates arising from mature copper/zinc superoxide dismutases resemble those observed in amyotrophic lateral sclerosis. The Journal of Biological Chemistry. 285: 41701-11. PMID 20974846 DOI: 10.1074/Jbc.M110.113696  0.685
2009 Weagant S, Karanassios V. Helium-hydrogen microplasma device (MPD) on postage-stamp-size plastic-quartz chips. Analytical and Bioanalytical Chemistry. 395: 577-89. PMID 19609509 DOI: 10.1007/S00216-009-2942-2  0.423
2007 Karanassios V, Johnson K, Smith AT. Micromachined, planar-geometry, atmospheric-pressure, battery-operated microplasma devices (MPDs) on chips for analysis of microsamples of liquids, solids, or gases by optical-emission spectrometry. Analytical and Bioanalytical Chemistry. 388: 1595-604. PMID 17426962 DOI: 10.1007/S00216-007-1273-4  0.436
2007 Ying X, Wang Y, Badiei HR, Karanassios V, Ma K. Purification and characterization of an iron-containing alcohol dehydrogenase in extremely thermophilic bacterium Thermotoga hypogea. Archives of Microbiology. 187: 499-510. PMID 17294170 DOI: 10.1007/S00203-007-0217-X  0.686
2006 Siemann S, Badiei HR, Karanassios V, Viswanatha T, Dmitrienko GI. 68Zn isotope exchange experiments reveal an unusual kinetic lability of the metal ions in the di-zinc form of IMP-1 metallo-beta-lactamase. Chemical Communications (Cambridge, England). 532-4. PMID 16432573 DOI: 10.1039/B514227J  0.714
2006 Karanassios V. Micro- and Nano-instrument Power Mrs Proceedings. 973. DOI: 10.1557/Proc-0973-Bb02-01  0.324
2006 Gibson B, Badiei HR, Karanassios V. Ti in dilute slurries of TiO2 nanoparticles by in-torch vaporization sector field inductively coupled plasma-mass spectrometry☆ Spectrochimica Acta Part B: Atomic Spectroscopy. 61: 753-758. DOI: 10.1016/J.Sab.2006.01.010  0.769
2006 Greib L, Karanassios V. Particle sample introduction system for inductively coupled plasma–atomic emission spectrometry Spectrochimica Acta Part B: Atomic Spectroscopy. 61: 164-180. DOI: 10.1016/J.Sab.2005.12.008  0.398
2004 Smith AT, Badiei HR, Evans JC, Karanassios V. Simultaneous determination of the Cd and Zn total body burden of individual, nearly microscopic, nanoliter-volume aquatic organisms ( Hyalella azteca) by rhenium-cup in-torch vaporization (ITV) sample introduction and axially viewed ICP-AES. Analytical and Bioanalytical Chemistry. 380: 212-7. PMID 15278332 DOI: 10.1007/S00216-004-2703-1  0.773
2004 Karanassios V. Microplasmas for chemical analysis: analytical tools or research toys? Spectrochimica Acta Part B: Atomic Spectroscopy. 59: 909-928. DOI: 10.1016/J.Sab.2004.04.005  0.419
2002 Badiei HR, Smith AT, Karanassios V. Rhenium-cup, in-torch vaporization (ITV) sample introduction for axially viewed ICP-AES and its application to the analysis of a microscopic, ng-weight solid sample Journal of Analytical Atomic Spectrometry. 17: 1030-1036. DOI: 10.1039/B203951F  0.786
2002 Badiei HR, Rutzke MA, Karanassios V. Calcium content of individual, microscopic, (sub) nanoliter volume Paramecium sp. cells using rhenium-cup in-torch vaporization (ITV) sample introduction and axially viewed ICP-AES Journal of Analytical Atomic Spectrometry. 17: 1007-1010. DOI: 10.1039/B203352F  0.745
2001 Vander Wilp W, Karanassios V. Lead in micro-samples of whole blood by Rhenium-cup in-torch vaporization-inductively coupled plasma-atomic emission spectrometry (ITV-ICP-AES). Fresenius' Journal of Analytical Chemistry. 368: 734-6. PMID 11227557 DOI: 10.1007/S002160000553  0.492
2000 Badiei HR, Karanassios V. Rhenium-cup in-torch vaporization inductively coupled plasma atomic emission spectrometry for liquid, slurry or solid micro-samples Journal of Analytical Atomic Spectrometry. 15: 1057-1062. DOI: 10.1039/B001781G  0.79
2000 Karanassios V, Wood TJ. Chapter 5 Direct sample insertion Comprehensive Analytical Chemistry. 34: 503-560. DOI: 10.1016/S0166-526X(00)34007-7  0.509
1999 Karanassios V, Wood TJ. Development and Characterization of an Automated Direct Sample Insertion/Inductively Coupled Plasma/Atomic Emission Spectrometry System Applied Spectroscopy. 53: 197-204. DOI: 10.1366/0003702991946325  0.486
1999 Badiei HR, Karanassios V. The influence of true simultaneous internal standardization and background correction on repeatability for laser ablation and the slurry technique coupled to ICP emission spectrometry Journal of Analytical Atomic Spectrometry. 14: 603-605. DOI: 10.1039/A807033D  0.776
1999 Karanassios V, Grishko V, Reynolds GG. Elemental analysis of micro-samples of liquids or slurries by coiled-filament in-torch vaporization-inductively coupled plasma atomic emission spectrometry (ITV-ICP-AES) Journal of Analytical Atomic Spectrometry. 14: 565-570. DOI: 10.1039/A807032F  0.537
1998 Karanassios V, Drouin P, Spiers G. Automated detection and interpretation of spectral information using cross-correlation, millilitre volumes, pneumatic nebulization sample introduction and inductively coupled plasma-atomic emission spectrometry with photodiode array detection Spectrochimica Acta Part B: Atomic Spectroscopy. 53: 1149-1166. DOI: 10.1016/S0584-8547(98)00131-1  0.411
1995 Karanassios V, Drouin P, Reynolds GG. Electrically heated wire-loop, in-torch vaporization (ITV) sample introduction system for ICP-AES with photomultiplier tube detection and ICP-MS Spectrochimica Acta Part B: Atomic Spectroscopy. 50: 415-423. DOI: 10.1016/0584-8547(94)00139-M  0.409
1994 Karanassios V, Bateman KP, Spiers GA. Correlation-based detection of spectral information using microliter volumes, in-torch vaporization (ITV) sample introduction and inductively coupled plasma atomic emission spectrometry with photodiode array detection Spectrochimica Acta Part B: Atomic Spectroscopy. 49: 989-1005. DOI: 10.1016/0584-8547(94)80086-3  0.418
1994 Karanassios V, Bateman KP, Spiers GA. Determination of mercury vapor in air using electrically heated, gold-coated wire-loops, in-torch vaporization sample introduction and inductively coupled plasma atomic emission spectrometry with photodiode array detection Spectrochimica Acta Part B: Atomic Spectroscopy. 49: 867-874. DOI: 10.1016/0584-8547(94)80076-6  0.438
1994 Karanassios V, Bateman KP, Spiers GA. Electrically heated wire-loop, in-torch vaporization sample introduction system for inductively coupled plasma atomic emission spectrometry with photodiode array detection Spectrochimica Acta Part B: Atomic Spectroscopy. 49: 847-865. DOI: 10.1016/0584-8547(94)80075-8  0.498
1992 Karanassios V, Usypchuck L, Moss P, Salin ED. Flame sample introduction system for inductively coupled plasma atomic emission spectrometry Journal of Analytical Atomic Spectrometry. 7: 1243. DOI: 10.1039/Ja9920701243  0.485
1991 Karanassios V, Ren JM, Salin ED. Electrothermal vaporization sample introduction system for the analysis of pelletized solids by inductively coupled plasma atomic emission spectrometry Journal of Analytical Atomic Spectrometry. 6: 527. DOI: 10.1039/Ja9910600527  0.53
1991 Karanassios V, Li FH, Liu B, Salin ED. Rapid stopped-flow microwave digestion system Journal of Analytical Atomic Spectrometry. 6: 457. DOI: 10.1039/Ja9910600457  0.472