Year |
Citation |
Score |
2018 |
Mohapatra H, Ayarza J, Sanders E, Scheuermann AM, Griffin P, Esser-Kahn AP. Ultrasound Promoted Step-Growth Polymerization and Polymer Crosslinking Via Copper Catalyzed Azide-Alkyne 'Click' (CuAAC) Reaction. Angewandte Chemie (International Ed. in English). PMID 29992680 DOI: 10.1002/Anie.201804451 |
0.374 |
|
2015 |
Brooks AD, Mohapatra H, Phillips ST. Design, Synthesis, and Characterization of Small-Molecule Reagents That Cooperatively Provide Dual Readouts for Triaging and, When Necessary, Quantifying Point-of-Need Enzyme Assays. The Journal of Organic Chemistry. 80: 10437-45. PMID 26458224 DOI: 10.1021/Acs.Joc.5B02013 |
0.645 |
|
2015 |
Mohapatra H, Kim H, Phillips ST. Stimuli-Responsive Polymer Film that Autonomously Translates a Molecular Detection Event into a Macroscopic Change in Its Optical Properties via a Continuous, Thiol-Mediated Self-Propagating Reaction. Journal of the American Chemical Society. PMID 26388422 DOI: 10.1021/Jacs.5B08582 |
0.644 |
|
2015 |
Kim H, Mohapatra H, Phillips ST. Rapid, On-Command Debonding of Stimuli-Responsive Cross-Linked Adhesives by Continuous, Sequential Quinone Methide Elimination Reactions. Angewandte Chemie (International Ed. in English). PMID 26347345 DOI: 10.1002/Anie.201506511 |
0.617 |
|
2015 |
Yeung K, Kim H, Mohapatra H, Phillips ST. Surface-accessible detection units in self-immolative polymers enable translation of selective molecular detection events into amplified responses in macroscopic, solid-state plastics. Journal of the American Chemical Society. 137: 5324-7. PMID 25891004 DOI: 10.1021/Jacs.5B02799 |
0.648 |
|
2013 |
Mohapatra H, Phillips ST. Reagents and assay strategies for quantifying active enzyme analytes using a personal glucose meter. Chemical Communications (Cambridge, England). 49: 6134-6. PMID 23727822 DOI: 10.1039/C3Cc43702G |
0.563 |
|
2012 |
Mohapatra H, Phillips ST. Phase switching to enable highly selective activity-based assays. Analytical Chemistry. 84: 8927-31. PMID 23075395 DOI: 10.1021/Ac302582H |
0.586 |
|
2012 |
Mohapatra H, Phillips ST. Using smell to triage samples in point-of-care assays. Angewandte Chemie (International Ed. in English). 51: 11145-8. PMID 23038662 DOI: 10.1002/Anie.201207008 |
0.587 |
|
2012 |
Mohapatra H, Schmid KM, Phillips ST. Design of small molecule reagents that enable signal amplification via an autocatalytic, base-mediated cascade elimination reaction. Chemical Communications (Cambridge, England). 48: 3018-20. PMID 22327299 DOI: 10.1039/C2Cc17566E |
0.615 |
|
Show low-probability matches. |