Ernö Pungor - Publications

Affiliations: 
Chemistry Budapest University of Technology and Economics, Budapest, Hungary 

68 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2012 Harsányi EG, Tóth K, Pungor E, Umezawa Y, Fujiwara S. Study of the potential response of solid-state chloride electrodes at low concentration ranges. Talanta. 31: 579-84. PMID 18963654 DOI: 10.1016/0039-9140(84)80173-3  0.45
1998 Pungor E. The Theory of Ion-Selective Electrodes Analytical Sciences. 14: 249-256. DOI: 10.2116/Analsci.14.249  0.429
1997 Pungor E. How to understand the response mechanism of ion-selective electrodes. Talanta. 44: 1505-1508. PMID 18966890 DOI: 10.1016/S0039-9140(96)02183-2  0.401
1993 Lindner E, Cosofret VV, Kusy RP, Buck RP, Rosatzin T, Schaller U, Simon W, Jeney J, Tóth K, Pungor E. Responses of H(+) selective solvent polymeric membrane electrodes fabricated from modified PVC membranes. Talanta. 40: 957-67. PMID 18965733 DOI: 10.1016/0039-9140(93)80151-G  0.312
1993 Nagy G, Tóth K, Pungor E. How far the Ion-Selectivity Should be Improved; a task Oriented Limit of Ion-Selective Electrode Design Analytical Letters. 26: 1391-1396. DOI: 10.1080/00032719308017420  0.425
1993 Fehér Z, Nagy G, Slezsák I, Tóth K, Pungor E. Triangle programmed coulometric flow titration with potentiometric and optical detection Analytica Chimica Acta. 273: 521-530. DOI: 10.1016/0003-2670(93)80198-T  0.355
1993 Horváth V, Horvai G, Pungor E. Ion exchange at neutral carrier ion-selective electrode membranes Fresenius Journal of Analytical Chemistry. 346: 569-571. DOI: 10.1007/Bf00321246  0.373
1993 Tóth K, Lindner E, Horváth M, Jeney J, Pungor E, Bitter I, Ágai B, Töke L. Analytical performances of lipophilic diamides based alkaline earth ion‐selective electrodes Electroanalysis. 5: 781-790. DOI: 10.1002/Elan.1140050911  0.397
1993 Tarcali J, Nagy G, Pungor E. Selective biocatalytic measuring cell for flow injection analysis Electroanalysis. 5: 277-281. DOI: 10.1002/Elan.1140050403  0.331
1991 Gratzl M, Tarcali J, Pungor E, Juhász G. Local depletion of monoamines induced with in vivo voltammetry in the cat brain. Neuroscience. 41: 287-93. PMID 1711652 DOI: 10.1016/0306-4522(91)90217-C  0.319
1991 Berube TR, Buck RP, Lindner E, Tòth K, Pungor E. Response of Liquid-Membrane Calcium-Selective Electrodes to Calcium Ion Activity Steps Analytical Letters. 24: 505-518. DOI: 10.1080/00032719108052921  0.418
1991 Huser M, Gehrig PM, Morf WE, Simon W, Lindner E, Jeney J, Toth K, Pungor E. Membrane technology and dynamic response of ion-selective liquid-membrane electrodes Analytical Chemistry. 63: 1380-1386. DOI: 10.1021/Ac00014A009  0.403
1991 Berube TR, Buck RP, Lindner E, Tòth K, Pungor E. Coupled diffusion/adsorption model for response of precipitate-based iodide-selective electrodes to primary-ion activity steps Analytical Chemistry. 63: 946-953. DOI: 10.1021/Ac00010A003  0.393
1991 Kolev SD, Nagy G, Pungor E. Mathematical modelling of single-line flow-injection analysis systems with single-layer enzyme electrode detection Part 3. Experimental verification of the model Analytica Chimica Acta. 254: 167-175. DOI: 10.1016/0003-2670(91)90023-X  0.594
1990 Wang K, Seiler K, Morf WE, Spichiger UE, Simon W, Lindner E, Pungor E. Characterization of potassium-selective optode membranes based on neutral ionophores and application in human blood plasma. Analytical Sciences. 6: 715-720. DOI: 10.2116/Analsci.6.715  0.345
1990 Tóth K, Lindner E, Pungor E, Kolev SD. Flow-injection approach for the determination of the dynamic response characteristics of ion-selective electrodes. Part 2. Application to tubular solid-state iodide electrode Analytica Chimica Acta. 234: 57-65. DOI: 10.1016/S0003-2670(00)83538-2  0.631
1990 Kolev SD, Tóth K, Lindner E, Pungor E. Flow-injection approach for the determination of the dynamic response characteristics of ion-selective electrodes. Part 1. Theoretical considerations Analytica Chimica Acta. 234: 49-56. DOI: 10.1016/S0003-2670(00)83537-0  0.637
1990 Kolev SD, Nagy G, Pungor E. Mathematical modelling of single-line flow-injection analysis systems with single-layer enzyme electrode detection Part 1. Development of the mathematical model Analytica Chimica Acta. 241: 43-53. DOI: 10.1016/S0003-2670(00)83263-8  0.586
1990 Umezawa Y, Ito K, Hata H, Sugawara M, Hars�nyi EG, T�th K, Pungor E, Soma M, Tanaka A. Surface chemistry and potential response of copper sulfide based ion-selective membrane in ligand solutions Mikrochimica Acta. 100: 231-239. DOI: 10.1007/Bf01244846  0.382
1990 Horváth V, Horvai G, Pungor E. Amperometric measurements with ion-selective electrode membranes in a flow system Mikrochimica Acta. 100: 217-224. DOI: 10.1007/Bf01244844  0.446
1990 Lindner E, Tóth K, Jeney J, Horváth M, Pungor E, Bitter I, Ágai B, Töke L. Novel bis (crown ether)-based potassium sensor for biological applications Mikrochimica Acta. 100: 157-168. DOI: 10.1007/Bf01244839  0.333
1989 Horvai G, Pungor E. Electrochemical Detectors in HPLC and Ion Chromatography. Critical Reviews in Analytical Chemistry. 21: 1-28. PMID 28135818 DOI: 10.1080/10408348908048814  0.39
1989 Berube TR, Buck RP, Lindner E, Gratzl M, Pungor E. Comparison of proposed response mechanisms of precipitate-based ion-selective electrodes in the presence of interfering ions Analytical Chemistry. 61: 453-458. DOI: 10.1021/Ac00180A015  0.398
1989 Horvai G, To´th K, Pungor E. Theoretical models of ion-selective electrode membranes Analytica Chimica Acta. 216: 163-176. DOI: 10.1016/S0003-2670(00)82008-5  0.438
1989 Horvai G, Horváth V, Farkas A, Pungor E. Selective ion-exchanger behaviour of neutral carrier ion-selective electrode membranes Talanta. 36: 403-405. DOI: 10.1016/0039-9140(89)80209-7  0.397
1988 Fehér Z, Kolbe I, Pungor E. Iodimetric determination of penicillins by a triangle programmed flow-through titration technique. Analyst. 113: 881-884. PMID 3218763 DOI: 10.1039/An9881300881  0.323
1988 Horvai G, Horváth V, Farkas A, Pungor E. Inorganic Salts Trapped In Neutral Carrier Ion-Selective Electrode Membranes Form Ion-Exchange Sites Analytical Letters. 21: 2165-2175. DOI: 10.1080/00032718808059900  0.383
1988 Hara H, Horvai G, Pungor E. Continuous flow determination of sulphate with a lead-selective electrode Analyst. 113: 1817-1820. DOI: 10.1039/An9881301817  0.417
1988 Kolev SD, Pungor E. Mathematical modeling of single-line flow-injection analysis systems without chemical reaction Analytical Chemistry. 60: 1700-1709. DOI: 10.1021/Ac00168A014  0.529
1988 Lindner E, Graf E, Niegreisz Z, Toth K, Pungor E, Buck RP. Responses of site-controlled, plasticized membrane electrodes Analytical Chemistry. 60: 295-301. DOI: 10.1021/Ac00155A004  0.349
1988 Iglehart ML, Buck RP, Pungor E. Plasticized poly(vinyl chloride) properties and characteristics of valinomycin electrodes. THE d.c. current-voltage curves Analytical Chemistry. 60: 290-295. DOI: 10.1021/Ac00155A003  0.304
1988 Kolev SD, Pungor E. Influence of the main parameters of single-line flow-injection systems without chemical reaction on the output signal Analytica Chimica Acta. 208: 133-149. DOI: 10.1016/S0003-2670(00)80741-2  0.544
1987 Pungor E, Tóth K. Ion Selective Electrodes A Review Analytical Sciences. 3: 387-393. DOI: 10.2116/Analsci.3.387  0.403
1987 Horvai G, Pungor E, Mottola HA. Theoretical Backgrounds of Flow Analysis Critical Reviews in Analytical Chemistry. 17: 231-264. DOI: 10.1080/10408348708542796  0.302
1987 Kolev SD, Pungor E. Unsteady motion in single-line flow-injection systems Analytica Chimica Acta. 201: 109-116. DOI: 10.1016/S0003-2670(00)85329-5  0.529
1987 Kolev SD, Pungor E. Numerical solution of hydraulic models based on the axially-dispersed plug flow model by Laplace transforms Analytica Chimica Acta. 194: 61-75. DOI: 10.1016/S0003-2670(00)84760-1  0.538
1986 Toth K, Graf E, Horvai G, Pungor E, Buck RP. Plasticized poly(vinyl chloride) properties and characteristics of valinomycin electrodes. 2. Low-frequency, surface-rate, and Warburg impedance characteristics Analytical Chemistry. 58: 2741-2744. DOI: 10.1021/Ac00126A035  0.321
1986 Gratzl M, Pungor E, Buck RP. Impedance measurements for pressed-pellet electrode membranes based on silver iodide and silver iodide/silver sulfide with solution contacts Analytica Chimica Acta. 189: 217-228. DOI: 10.1016/S0003-2670(00)83724-1  0.315
1986 Kolev SD, Pungor E. Description of an axially-dispersed plug flow model for the flow pattern in elements of fluid systems Analytica Chimica Acta. 185: 315-319. DOI: 10.1016/0003-2670(86)80059-9  0.538
1985 Gratzl M, Lindner E, Pungor E. Theoretical interpretation of transient signals obtained with precipitate-based ion-selective electrodes in the presence of interfering ions Analytical Chemistry. 57: 1506-1511. DOI: 10.1021/Ac00285A004  0.398
1985 Ammann D, Pretsch E, Simon W, Lindner E, Bezegh A, Pungor E. Lipophilic salts as membrane additives and their influence on the properties of macro- and micro-electrodes based on neutral carriers Analytica Chimica Acta. 171: 119-129. DOI: 10.1016/S0003-2670(00)84189-6  0.384
1984 Lindner E, Toth K, Pungor E. Definition of the response time of ion-selective electrodes and potentiometric cells Analytical Chemistry. 56: 808-810. DOI: 10.1021/Ac00268A050  0.417
1983 Pungor E, Tóth K, Klatsmanyi PG, Izutsu K. Applications of ion-selective electrodes in nonaqueous and mixed solvents Pure and Applied Chemistry. 55: 2029-2065. DOI: 10.1351/Pac198355122029  0.422
1983 Horvai G, Pungor E. Precision of the double known addition method in ion-selective electrode potentiometry Analytical Chemistry. 55: 1988-1990. DOI: 10.1021/Ac00262A036  0.423
1983 Pungor E, Umezawa Y. Response time in electrochemical cells containing ion-selective electrodes Analytical Chemistry. 55: 1432-1432. DOI: 10.1021/Ac00259A059  0.426
1983 Bates RG, Dickson AG, Gratzl M, Hrabeczy-Pall A, Lindner E, Pungor E. Determination of mean activity coefficients with ion-selective electrodes Analytical Chemistry. 55: 1275-1280. DOI: 10.1021/Ac00259A021  0.415
1982 Harsanyi EG, Toth K, Polos L, Pungor E. Adsorption phenomena of silver iodide based ion-selective electrodes Analytical Chemistry. 54: 1094-1097. DOI: 10.1021/Ac00244A018  0.402
1982 Lindner E, Toth K, Pungor E. Dynamic response of precipitate-based ion-selective electrodes in the presence of interfering ions Analytical Chemistry. 54: 202-207. DOI: 10.1021/Ac00239A013  0.399
1982 Lindner E, Toth K, Pungor E. Response time studies for precipitate-based ion-selective electrodes in the range of the lower detection limit Analytical Chemistry. 54: 72-76. DOI: 10.1021/Ac00238A023  0.423
1980 Tóth K, Nagy G, Fehér Z, Horvai G, Pungor E. The application of electroanalytical detectors in continuous flow analysis Analytica Chimica Acta. 114: 45-58. DOI: 10.1016/S0003-2670(01)84278-1  0.301
1979 Nagy G, Fehér Z, Tóth K, Pungor E, Ivaska A. Evaluation of acid-base titration curves obtained by the triangle-programmed titration technique in flowing solutions. Talanta. 26: 1143-1153. PMID 18962591 DOI: 10.1016/0039-9140(79)80030-2  0.306
1978 Lindner E, Toth K, Pungor E, Morf WE, Simon W. Response time studies on neutral carrier ion-selective membrane electrodes Analytical Chemistry. 50: 1627-1631. DOI: 10.1021/Ac50034A014  0.426
1976 Fritz I, Nagy G, Fodor L, Pungor E. In vitro studies on the dissolution rate of industrial retarted urea feedingstuffs by use of a selective electrode. Applications of the potentiometric urea enzyme electrode in measurements of dissolution rate. The Analyst. 101: 439-44. PMID 937731 DOI: 10.1039/An9760100439  0.409
1976 Lindner E, Toth K, Pungor E. Response time curves of ion-selective electrodes Analytical Chemistry. 48: 1071-1078. DOI: 10.1021/Ac60371A009  0.422
1976 El-Taras MF, Pungor E, Nagy G. The influence of some organic complexing agents on the potential of copper(II) - selective electrodes. application of the silicone rubber-based electrode to the determination of citrate ion and 8-hydroxyquinoline Analytica Chimica Acta. 82: 285-292. DOI: 10.1016/S0003-2670(01)84606-7  0.393
1975 Hrabéczy-Páll A, Tóth K, Pungor E, Valló F. Application of a fluoride-selective electrode to the monitoring of fluoride in air Analytica Chimica Acta. 77: 278-282. DOI: 10.1016/S0003-2670(01)95181-5  0.373
1975 Neshkova MT, Izvekov VP, ̄apay MKP, Tóth K, Pungor E. Potentiometric studies on organic compounds containing sulphur with a sulphide ion-selective membrane electrode, direct potentiometric titration of som Analytica Chimica Acta. 75: 439-444. DOI: 10.1016/S0003-2670(01)85369-1  0.387
1974 Pápay MK, Izvekov VP, Tóth K, Pungor E. Potentiometric studies on organic compounds containing sulphur with a sulphide ion-selective membrane electrode Analytica Chimica Acta. 69: 173-182. DOI: 10.1016/0003-2670(74)80020-6  0.355
1973 Pungor E, Tóth K. Precipitate-based ion-selective electrodes Pure and Applied Chemistry. 34: 105-138. DOI: 10.1351/Pac197334010105  0.426
1973 Pápay MK, Tóth K, Izvekov V, Pungor E. Potentiometric studies on thioacetamide by means of a sulphide ion-selective membrane electrode Analytica Chimica Acta. 64: 409-415. DOI: 10.1016/S0003-2670(01)82472-7  0.37
1972 Horvai G, Horváth V, Farkas A, Pungor E. Inorganic Salts Trapped in Neutral Carrier Ion-Selective Electrode Membranes form Ion-Exchange Sites Journal of Macromolecular Science, Part A. 6: 2165-2175. DOI: 10.1080/10601327208056837  0.404
1972 Izvekov VP, Kucsera-Pápay M, Tóth K, Pungor E. Potentiometric determination of p-urazine with an ion-selective electrode Analyst. 97: 634-638. DOI: 10.1039/An9729700634  0.339
1971 Szepesváry É, Pungor E. Potentiometric determination of acids and bases with a silicone rubber-based graphite electrode as indicating electrode Analytica Chimica Acta. 54: 199-208. DOI: 10.1016/S0003-2670(01)82120-6  0.398
1971 Tóth K, Gavallér I, Pungor E. Transient phenomena of ion-selective membrane electrodes Analytica Chimica Acta. 57: 131-135. DOI: 10.1016/S0003-2670(01)80137-9  0.459
1970 Pungor E, Tóth K. Ion-selective membrane electrodes. A review Analyst. 95: 625-648. DOI: 10.1039/An9709500625  0.411
1970 To´th K, Pungor E. Determination of cyanides with ion-selective membrane electrodes Analytica Chimica Acta. 51: 221-230. DOI: 10.1016/S0003-2670(01)95710-1  0.439
1969 Pungor E, Tóth K. Selectivity of ion-specific membrane electrodes Analytica Chimica Acta. 47: 291-297. DOI: 10.1016/S0003-2670(01)95680-6  0.442
1968 Pungor E, Szepesvary E, Havas J. Voltammetric Studies on Graphite Impregnated Silicone Rubber Electrodes Analytical Letters. 1: 213-220. DOI: 10.1080/00032716808051120  0.355
Show low-probability matches.