Robert Koncki - Publications

Affiliations: 
1995-1996 University of Warsaw, Poland 

102 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2023 Głowacka J, Wiśniewska A, Koncki R, Strzelak K. Photometric flow system for the determination of serum lactate dehydrogenase activity. Talanta. 265: 124817. PMID 37418958 DOI: 10.1016/j.talanta.2023.124817  0.306
2022 Głowacka J, Koncki R, Strzelak K. Multicommutation flow analysis system for non-enzymatic lactate determination based on light-driven photometric assay. Analytica Chimica Acta. 1210: 339878. PMID 35595361 DOI: 10.1016/j.aca.2022.339878  0.314
2021 Głowacka J, Strzelak K, Koncki R. Multicommutated Flow Analysis System for Determination of Horseradish Peroxidase and Its Inhibitors. Molecules (Basel, Switzerland). 26. PMID 34577101 DOI: 10.3390/molecules26185630  0.318
2020 Fiedoruk-Pogrebniak M, Koncki R. LED&Paper-based analytical device for phosphatemia/calcemia diagnostics☆. Journal of Pharmaceutical and Biomedical Analysis. 186: 113321. PMID 32413826 DOI: 10.1016/J.Jpba.2020.113321  0.362
2020 Strzelak K, Głowacka J, Koncki R. Towards mechanized biparametric ceruloplasmin assay. Talanta. 214: 120881. PMID 32278433 DOI: 10.1016/J.Talanta.2020.120881  0.416
2020 Ding R, Fiedoruk-Pogrebniak M, Pokrzywnicka M, Koncki R, Bobacka J, Lisak G. Solid reference electrode integrated with paper-based microfluidics for potentiometric ion sensing Sensors and Actuators B-Chemical. 323: 128680. DOI: 10.1016/J.Snb.2020.128680  0.365
2019 Skoczek J, Pokrzywnicka M, Kubacka O, Koncki R. A multi-pumping flow analysis system for β-galactosidase activity assays. Food Chemistry. 294: 231-237. PMID 31126458 DOI: 10.1016/J.Foodchem.2019.04.045  0.436
2019 Michalec M, Koncki R, Tymecki Ł. Optoelectronic detectors for flow analysis systems manufactured by means of rapid prototyping technology. Talanta. 198: 169-178. PMID 30876546 DOI: 10.1016/J.Talanta.2019.01.092  0.377
2019 Bzura J, Koncki R. A mechanized urease activity assay. Enzyme and Microbial Technology. 123: 1-7. PMID 30686345 DOI: 10.1016/J.Enzmictec.2019.01.001  0.416
2019 Strzelak K, Koncki R. A remote-controlled immunochemical system for nephelometric detection of human serum transferrin. Biosensors & Bioelectronics. 127: 31-37. PMID 30590220 DOI: 10.1016/J.Bios.2018.12.011  0.421
2018 Bzura J, Fiedoruk-Pogrebniak M, Koncki R. Photometric and fluorometric alkaline phosphatase assays using the simplest enzyme substrates. Talanta. 190: 193-198. PMID 30172498 DOI: 10.1016/J.Talanta.2018.07.052  0.415
2018 Inpota P, Strzelak K, Koncki R, Sripumkhai W, Jeamsaksiri W, Ratanawimarnwong N, Wilairat P, Choengchan N, Chantiwas R, Nacapricha D. Microfluidic Analysis with Front-Face Fluorometric Detection for the Determination of Total Inorganic Iodine in Drinking Water. Analytical Sciences : the International Journal of the Japan Society For Analytical Chemistry. 34: 161-167. PMID 29434101 DOI: 10.2116/Analsci.34.161  0.36
2018 Fiedoruk-Pogrebniak M, Granica M, Koncki R. Compact detectors made of paired LEDs for photometric and fluorometric measurements on paper. Talanta. 178: 31-36. PMID 29136828 DOI: 10.1016/J.Talanta.2017.08.091  0.376
2018 Pokrzywnicka M, Koncki R. Disaccharides Determination: A Review of Analytical Methods. Critical Reviews in Analytical Chemistry. 48: 186-213. PMID 29053338 DOI: 10.1080/10408347.2017.1391683  0.355
2018 Granica M, Fiedoruk-Pogrebniak M, Koncki R, Tymecki Ł. Flow injection analysis in lab-on-paper format Sensors and Actuators B-Chemical. 257: 16-22. DOI: 10.1016/J.Snb.2017.10.088  0.38
2018 Rybkowska N, Strzelak K, Koncki R. A comparison of photometric methods for serum iron determination under flow analysis conditions Sensors and Actuators B-Chemical. 254: 307-313. DOI: 10.1016/J.Snb.2017.07.059  0.326
2017 Strzelak K, Rybkowska N, Wiśniewska A, Koncki R. Photometric flow analysis system for biomedical investigations of iron/transferrin speciation in human serum. Analytica Chimica Acta. 995: 43-51. PMID 29126480 DOI: 10.1016/J.Aca.2017.10.015  0.314
2017 Rybkowska N, Koncki R, Strzelak K. Optoelectronic iron detectors for pharmaceutical flow analysis. Journal of Pharmaceutical and Biomedical Analysis. 145: 504-508. PMID 28746909 DOI: 10.1016/J.Jpba.2017.06.057  0.371
2016 Pokrzywnicka M, Kamiński J, Michalec M, Koncki R, Tymecki Ł. A multicommutated tester of bioreactors for flow analysis. Talanta. 160: 233-240. PMID 27591609 DOI: 10.1016/J.Talanta.2016.07.008  0.448
2016 Michalec M, Tymecki Ł, Koncki R. Biomedical analytical monitor of artificial kidney operation: Monitoring of creatinine removal. Journal of Pharmaceutical and Biomedical Analysis. 128: 28-34. PMID 27214506 DOI: 10.1016/J.Jpba.2016.04.021  0.395
2016 Michalec M, Fiedoruk-Pogrebniak M, Matuszkiewicz-Rowińska J, Tymecki Ł, Koncki R. Biomedical monitoring of phosphate removal by hemodialysis. Journal of Pharmaceutical and Biomedical Analysis. 126: 9-13. PMID 27136282 DOI: 10.1016/J.Jpba.2016.04.034  0.41
2016 Strzelak K, Misztal J, Tymecki Ł, Koncki R. Bianalyte multicommutated flow analysis system for microproteinuria diagnostics. Talanta. 148: 707-11. PMID 26653505 DOI: 10.1016/J.Talanta.2015.04.021  0.404
2016 Michalec M, Granica M, Bzura J, Koncki R, Matuszkiewicz-Rowińska J, Tymecki Ł. Optoelectronic detectors and flow analysis systems for determination of dialysate urea nitrogen Sensors and Actuators B-Chemical. 226: 563-569. DOI: 10.1016/J.Snb.2015.12.021  0.472
2015 Fiedoruk-Pogrebniak M, Koncki R. Multicommutated flow analysis system based on fluorescence microdetectors for simultaneous determination of phosphate and calcium ions in human serum. Talanta. 144: 184-8. PMID 26452808 DOI: 10.1016/J.Talanta.2015.06.001  0.407
2015 Strzelak K, Koncki R. An immunoprecipitation assay in the multicommutated flow analysis format. The Analyst. 140: 7271-7. PMID 26347907 DOI: 10.1039/C5An01402F  0.41
2015 Pokrzywnicka M, Koncki R, Tymecki Ł. Towards optoelectronic urea biosensors. Analytical and Bioanalytical Chemistry. 407: 1807-12. PMID 25619983 DOI: 10.1007/S00216-014-8434-Z  0.45
2015 Fiedoruk M, Cocovi-Solberg DJ, Tymecki Ł, Koncki R, Miró M. Hybrid flow system integrating a miniaturized optoelectronic detector for on-line dynamic fractionation and fluorometric determination of bioaccessible orthophosphate in soils. Talanta. 133: 59-65. PMID 25435227 DOI: 10.1016/J.Talanta.2014.05.063  0.371
2014 Kołacińska K, Koncki R. A novel optoelectronic detector and improved flow analysis procedure for ammonia determination with Nessler's reagent. Analytical Sciences : the International Journal of the Japan Society For Analytical Chemistry. 30: 1019-22. PMID 25312634 DOI: 10.2116/Analsci.30.1019  0.423
2014 Fiedoruk M, Mieczkowska E, Koncki R, Tymecki L. A bimodal optoelectronic flow-through detector for phosphate determination. Talanta. 128: 211-4. PMID 25059150 DOI: 10.1016/J.Talanta.2014.04.086  0.437
2014 Strzelak K, Wiśniewska A, Bobilewicz D, Koncki R. Multicommutated flow analysis system for determination of total protein in cerebrospinal fluid. Talanta. 128: 38-43. PMID 25059127 DOI: 10.1016/J.Talanta.2014.04.047  0.388
2013 Tymecki Ł, Strzelak K, Koncki R. Biparametric multicommutated flow analysis system for determination of human serum phosphoesterase activity. Analytica Chimica Acta. 797: 57-63. PMID 24050670 DOI: 10.1016/J.Aca.2013.08.047  0.409
2013 Strzelak K, Koncki R. Nephelometry and turbidimetry with paired emitter detector diodes and their application for determination of total urinary protein. Analytica Chimica Acta. 788: 68-73. PMID 23845483 DOI: 10.1016/J.Aca.2013.06.003  0.395
2013 Tymecki Ł, Korszun J, Strzelak K, Koncki R. Multicommutated flow analysis system for determination of creatinine in physiological fluids by Jaffe method. Analytica Chimica Acta. 787: 118-25. PMID 23830429 DOI: 10.1016/J.Aca.2013.05.052  0.444
2012 Strzelak K, Koncki R, Tymecki L. Serum alkaline phosphatase assay with paired emitter detector diode. Talanta. 96: 127-31. PMID 22817939 DOI: 10.1016/J.Talanta.2012.01.031  0.449
2012 Pokrzywnicka M, Tymecki L, Koncki R. Low-cost optical detectors and flow systems for protein determination. Talanta. 96: 121-6. PMID 22817938 DOI: 10.1016/J.Talanta.2012.01.061  0.385
2012 Cocovi-Solberg DJ, Miró M, Cerdà V, Pokrzywnicka M, Tymecki L, Koncki R. Towards the development of a miniaturized fiberless optofluidic biosensor for glucose. Talanta. 96: 113-20. PMID 22817937 DOI: 10.1016/J.Talanta.2011.11.021  0.386
2012 Pokrzywnicka M, Fiedoruk M, Koncki R. Compact optoelectronic flow-through device for fluorometric determination of calcium ions. Talanta. 93: 106-10. PMID 22483884 DOI: 10.1016/J.Talanta.2012.01.055  0.408
2012 Tymecki L, Rejnis M, Pokrzywnicka M, Strzelak K, Koncki R. Fluorimetric detector and sensor for flow analysis made of light emitting diodes. Analytica Chimica Acta. 721: 92-6. PMID 22405305 DOI: 10.1016/J.Aca.2012.01.029  0.434
2011 Pokrzywnicka M, Cocovi-Solberg DJ, Miró M, Cerdà V, Koncki R, Tymecki Ł. Miniaturized optical chemosensor for flow-based assays. Analytical and Bioanalytical Chemistry. 399: 1381-7. PMID 21103867 DOI: 10.1007/S00216-010-4384-2  0.452
2011 Mieczkowska E, Koncki R, Tymecki Ł. Hemoglobin determination with paired emitter detector diode. Analytical and Bioanalytical Chemistry. 399: 3293-7. PMID 21046074 DOI: 10.1007/S00216-010-4358-4  0.355
2011 Tymecki Ł, Pokrzywnicka M, Koncki R. Fluorometric paired emitter detector diode (FPEDD). The Analyst. 136: 73-6. PMID 20981394 DOI: 10.1039/C0An00227E  0.337
2011 Rozum B, Koncki R. Analytical study on cofactor biorecognition by immobilized alkaline apophosphatase Sensors and Actuators B-Chemical. 155: 323-330. DOI: 10.1016/J.Snb.2011.04.014  0.465
2010 Pokrzywnicka M, Koncki R, Tymecki Ł. A concept of dual optical detection using three light emitting diodes. Talanta. 82: 422-5. PMID 20685488 DOI: 10.1016/J.Talanta.2010.04.026  0.378
2010 Rozum B, Gajownik K, Tymecki L, Koncki R. Poly(vinyl chloride) tubing with covalently bound alkaline phosphatase and alternative approach for investigations of open-tubular bioreactors. Analytical Biochemistry. 400: 151-3. PMID 20083084 DOI: 10.1016/J.Ab.2010.01.016  0.408
2009 Tymecki Ł, Brodacka L, Rozum B, Koncki R. UV-PEDD photometry dedicated for bioanalytical uses. The Analyst. 134: 1333-7. PMID 19562198 DOI: 10.1039/B822025E  0.373
2009 Tymecki L, Strzelak K, Koncki R. A single standard calibration module for flow analysis systems based on solenoid microdevices. Talanta. 79: 205-10. PMID 19559866 DOI: 10.1016/J.Talanta.2009.03.028  0.408
2009 Tymecki Ł, Koncki R. Simplified paired-emitter-detector-diodes-based photometry with improved sensitivity. Analytica Chimica Acta. 639: 73-7. PMID 19345761 DOI: 10.1016/J.Aca.2009.03.014  0.431
2008 Tymecki Ł, Pokrzywnicka M, Koncki R. Paired emitter detector diode (PEDD)-based photometry--an alternative approach. The Analyst. 133: 1501-4. PMID 18936826 DOI: 10.1039/B807127F  0.321
2008 Ogonczyk D, Glab S, Koncki R. An automated potentiometric assay for acid phosphatase. Analytical Biochemistry. 381: 169-71. PMID 18601894 DOI: 10.1016/J.Ab.2008.06.012  0.413
2008 Rozum B, Koncki R. Application of monofluorophosphate/alkaline phosphatase system in flow injection analysis Talanta. 77: 507-513. DOI: 10.1016/J.Talanta.2008.04.005  0.416
2007 Ogończyk D, Koncki R. Potentiometric flow-injection system for determination of alkaline phosphatase in human serum. Analytica Chimica Acta. 600: 194-8. PMID 17903484 DOI: 10.1016/J.Aca.2007.02.026  0.433
2007 Koncki R. Recent developments in potentiometric biosensors for biomedical analysis. Analytica Chimica Acta. 599: 7-15. PMID 17765058 DOI: 10.1016/J.Aca.2007.08.003  0.374
2007 Rozum B, Koncki R, Tymecki Ł. Potentialities of pH-electrode modified with alkaline phosphatase Sensors and Actuators B-Chemical. 127: 632-636. DOI: 10.1016/J.Snb.2007.05.033  0.437
2006 Koncki R, Rozum B, Głab S. pH-metric detection of alkaline phosphatase activity as a novel biosensing platform. Talanta. 68: 1020-5. PMID 18970426 DOI: 10.1016/J.Talanta.2005.07.002  0.442
2006 Koncki R, Rudnicka K, Tymecki Ł. Flow injection system for potentiometric determination of alkaline phosphatase inhibitors. Analytica Chimica Acta. 577: 134-9. PMID 17723664 DOI: 10.1016/J.Aca.2006.05.100  0.449
2006 Tymecki L, Glab S, Koncki R. Miniaturized, Planar Ion-selective Electrodes Fabricated by Means of Thick-film Technology Sensors. 6: 390-396. DOI: 10.3390/S6040390  0.364
2006 Tymecki Ł, Koncki R. Thick-film potentiometric biosensor for bloodless monitoring of hemodialysis Sensors and Actuators B-Chemical. 113: 782-786. DOI: 10.1016/J.Snb.2005.07.045  0.472
2005 Ogończyk D, Tymecki Ł, Wyżkiewicz I, Koncki R, Głąb S. Screen-printed disposable urease-based biosensors for inhibitive detection of heavy metal ions Sensors and Actuators B-Chemical. 106: 450-454. DOI: 10.1016/J.Snb.2004.09.005  0.405
2005 Koncki R, Ogończyk D, Głąb S. Potentiometric assay for acid and alkaline phosphatase Analytica Chimica Acta. 538: 257-261. DOI: 10.1016/J.Aca.2005.02.021  0.447
2005 Tymecki Ł, Zwierkowska E, Koncki R. Strip bioelectrochemical cell for potentiometric measurements fabricated by screen-printing Analytica Chimica Acta. 538: 251-256. DOI: 10.1016/J.Aca.2005.02.011  0.455
2004 Radomska A, Bodenszac E, Gła B S, Koncki R. Creatinine biosensor based on ammonium ion selective electrode and its application in flow-injection analysis. Talanta. 64: 603-8. PMID 18969648 DOI: 10.1016/J.Talanta.2004.03.033  0.491
2004 Tymecki Ł, Zwierkowska E, Koncki R. Screen-printed reference electrodes for potentiometric measurements Analytica Chimica Acta. 526: 3-11. DOI: 10.1016/J.Aca.2004.08.056  0.379
2004 Radomska A, Koncki R, Pyrzyńska K, Głąb S. Bioanalytical system for control of hemodialysis treatment based on potentiometric biosensors for urea and creatinine Analytica Chimica Acta. 523: 193-200. DOI: 10.1016/J.Aca.2004.06.048  0.467
2003 Pobozy E, Radomska A, Koncki R, Głab S. Determination of dialysate creatinine by micellar electrokinetic chromatography. Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences. 789: 417-24. PMID 12742133 DOI: 10.1016/S1570-0232(03)00075-8  0.382
2003 Tymecki Ł, Zwierkowska E, Głąb S, Koncki R. Strip thick-film silver ion-selective electrodes Sensors and Actuators B-Chemical. 96: 482-488. DOI: 10.1016/S0925-4005(03)00622-1  0.429
2003 Derwinska K, Miecznikowski K, Koncki R, Kulesza PJ, Glab S, Malik MA. Application of Prussian Blue Based Composite Film with Functionalized Organic Polymer to Construction of Enzymatic Glucose Biosensor Electroanalysis. 15: 1843-1849. DOI: 10.1002/Elan.200302761  0.398
2002 Koncki R. Chemical Sensors and Biosensors Based on Prussian Blues Critical Reviews in Analytical Chemistry. 32: 79-96. DOI: 10.1080/10408340290765452  0.35
2001 Radomska A, Glab S, Koncki R. Spectrophotometric bioanalytical flow-injection system for control of hemodialysis treatment. Analyst. 126: 1564-1567. PMID 11592650 DOI: 10.1039/B104140C  0.471
2001 Koncki R, Lenarczuk T, Radomska A, Głąb S. Optical biosensors based on Prussian Blue films Analyst. 126: 1080-1085. PMID 11478639 DOI: 10.1039/B103044M  0.399
2001 Lenarczuk T, Głąb S, Koncki R. Application of Prussian blue-based optical sensor in pharmaceutical analysis. Journal of Pharmaceutical and Biomedical Analysis. 26: 163-169. PMID 11451654 DOI: 10.1016/S0731-7085(01)00398-3  0.457
2001 Tymecki Ł, Jakubowska M, Achmatowicz S, Koncki R, Głąb S. Potentiometric Thick-Film Graphite Electrodes With Improved Response To Copper Ions Analytical Letters. 34: 71-78. DOI: 10.1081/Al-100002705  0.389
2001 Lenarczuk T, Wencel D, Głąb S, Koncki R. Prussian blue-based optical glucose biosensor in flow-injection analysis Analytica Chimica Acta. 447: 23-32. DOI: 10.1016/S0003-2670(01)01289-2  0.409
2000 Koncki R. Potentiometric determination of dialysate urea nitrogen Talanta. 52: 13-17. PMID 18967957 DOI: 10.1016/S0039-9140(99)00346-X  0.468
2000 Koncki R, Tymecki Ł, Zwierkowska E, Głąb S. Screen-printed copper ion-selective electrodes. Fresenius Journal of Analytical Chemistry. 367: 393-395. PMID 11225868 DOI: 10.1007/S002160000408  0.405
2000 Lenarczuk T, Roszczyk I, Koncki R. Quick cuvette test for thiol compounds Analytical Letters. 33: 137-144. DOI: 10.1080/00032710008543042  0.306
2000 Koncki R, Lenarczuk T, Głąb S. Optical sensing schemes for Prussian Blue/Prussian White film system Analytica Chimica Acta. 424: 27-35. DOI: 10.1016/S0003-2670(00)01144-2  0.336
2000 Koncki R, Radomska A, Głąb S. Bioanalytical flow-injection system for control of hemodialysis adequacy Analytica Chimica Acta. 418: 213-224. DOI: 10.1016/S0003-2670(00)00961-2  0.447
1999 Koncki R, Wałcerz I, Leszczyńska E. Enzymatically modified ion-selective electrodes for flow injection analysis Journal of Pharmaceutical and Biomedical Analysis. 19: 633-638. PMID 10704130 DOI: 10.1016/S0731-7085(98)00230-1  0.431
1999 Koncki R, Chudzik A, Walcerz I. Urea determination using pH-enzyme electrode. Journal of Pharmaceutical and Biomedical Analysis. 21: 51-57. PMID 10701912 DOI: 10.1016/S0731-7085(99)00094-1  0.469
1999 Koncki R, Wolfbeis OS. Composite films of Prussian blue and N-substituted polypyrroles: covalent immobilization of enzymes and application to near infrared optical biosensing. Biosensors & Bioelectronics. 14: 87-92. PMID 10028653 DOI: 10.1016/S0956-5663(98)00095-5  0.541
1999 Koncki R, Głąb S, Dziwulska J, Palchetti I, Mascini M. Disposable strip potentiometric electrodes with solvent-polymeric ion-selective membranes fabricated using screen-printing technology Analytica Chimica Acta. 385: 451-459. DOI: 10.1016/S0003-2670(98)00726-0  0.397
1999 Koncki R, Lenarczuk T, Głąb S. Disposable integrated cuvette test for quantitative determination of vitamin C in pharmaceutical products Analytica Chimica Acta. 379: 69-74. DOI: 10.1016/S0003-2670(98)00653-9  0.334
1998 Koncki R, Wolfbeis OS. Composite Films of Prussian Blue and N-Substituted Polypyrroles: Fabrication and Application to Optical Determination of pH. Analytical Chemistry. 70: 2544-2550. PMID 21644774 DOI: 10.1021/Ac9712714  0.514
1998 Koncki R, Wolfbeis OS. Optical chemical sensing based on thin films of Prussian Blue Sensors and Actuators B-Chemical. 51: 355-358. DOI: 10.1016/S0925-4005(98)00287-1  0.494
1998 Koncki R, Owczarek A, Dzwolak W, Głąb S. Immunoenzymatic sensitisation of membrane ion-selective electrodes Sensors and Actuators B-Chemical. 47: 246-250. DOI: 10.1016/S0925-4005(98)00031-8  0.39
1998 Wałcerz I, Głąb S, Koncki R. Potentiometric enzyme electrode in a flow injection system for the determination of urea in human serum samples Analytica Chimica Acta. 369: 129-137. DOI: 10.1016/S0003-2670(98)00222-0  0.45
1998 Leszczyńska E, Głąb S, Sokół A, Dzięgielewski K, Rokicka R, Koncki R. Potentiometric biosensor for control of biotechnological production of penicillin G Analytica Chimica Acta. 368: 205-210. DOI: 10.1016/S0003-2670(98)00206-2  0.469
1997 Koncki R, Hulanicki A, Gła̧b S. Biochemical modifications of membrane ion-selective sensors Trends in Analytical Chemistry. 16: 528-536. DOI: 10.1016/S0165-9936(97)00066-6  0.388
1996 Wałcerz I, Koncki R, Leszczyńska E, Salamonowicz B, Głąb S. Urea Biosensors Based on PVC Membrane Ion-Selective Electrodes Analytical Letters. 29: 1939-1953. DOI: 10.1080/00032719608000800  0.432
1996 Koncki R, Wałcerz I, Ruckruh F, Głab S. Bienzymatic potentiometric electrodes for creatine and l-arginine determination Analytica Chimica Acta. 333: 215-222. DOI: 10.1016/0003-2670(96)00266-8  0.413
1996 Koncki R, Leszczyńska E, Cybulska A, Głab S. Penicillin enzyme biosensors based on pH membrane electrodes Analytica Chimica Acta. 321: 27-34. DOI: 10.1016/0003-2670(95)00547-1  0.395
1995 Koncki R, Mohr GJ, Wolfbeis OS. Enzyme biosensor for urea based on a novel pH bulk optode membrane. Biosensors & Bioelectronics. 10: 653-9. PMID 7576433 DOI: 10.1016/0956-5663(95)96955-X  0.537
1995 Koncki R, Głąb S. Kinetic model of pH-based potentiometric enzymic sensors. Part 4. Enzyme loading and lifetime factors Analyst. 120: 489-493. DOI: 10.1039/An9952000489  0.39
1995 Wałcerz I, Koncki R, Leszczyńska E, Gła̧b S. Enzyme biosensors for urea determination based on an ionophore free pH membrane electrode Analytica Chimica Acta. 315: 289-296. DOI: 10.1016/0003-2670(95)00313-O  0.435
1994 Gła̧b S, Koncki R, Kopczewska E, Wałcerz I, Hulanicki A. Urea sensors based on PVC membrane pH electrode. Talanta. 41: 1201-1205. PMID 18966057 DOI: 10.1016/0039-9140(94)80092-8  0.391
1994 Koncki R, Kopczewska E, Glab S. Comparison of pH-Membrane Enzyme Electrodes for Urea with Covalently Bound Enzyme. Analytical Letters. 27: 475-486. DOI: 10.1080/00032719408001088  0.413
1993 Koncki R, Ga̵b S, Hulanicki A. Simplex method for the computation of analytical parameters of potentiometric sensors Analytica Chimica Acta. 273: 477-483. DOI: 10.1016/0003-2670(93)80193-O  0.412
1992 Głąb S, Koncki R, Hulanicki A. Kinetic model of pH-based potentiometric enzymic sensors. Part 3. Experimental verification Analyst. 117: 1675-1678. DOI: 10.1039/An9921701675  0.419
1992 Głąb S, Koncki R, Holona I. Kinetic model of pH-based potentiometric enzymic sensors. Part 2. Method of fitting Analyst. 117: 1671-1674. DOI: 10.1039/An9921701671  0.372
1992 Koncki R, Leszcyński P, Hulanicki A, Gła̧b S. Urea sensors based on glass pH electrodes with physically immobilized urease Analytica Chimica Acta. 257: 67-72. DOI: 10.1016/0003-2670(92)80151-V  0.4
1991 Głab S, Koncki R, Hulanicki A. Kinetic model of pH-based potentiometric enzymic sensors. Part 1. Theoretical considerations Analyst. 116: 453-458. DOI: 10.1039/An9911600453  0.38
1991 Głab S, Koncki R, Hulanicki A. Theoretical model of the response of pH‐based enzyme sensors Electroanalysis. 3: 361-364. DOI: 10.1002/Elan.1140030419  0.387
Show low-probability matches.