Jim X. Ji, Ph.D. - Publications

Affiliations: 
2003 University of Illinois, Urbana-Champaign, Urbana-Champaign, IL 
Area:
Electronics and Electrical Engineering, Biomedical Engineering

54 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2020 Mecheter I, Alic L, Abbod M, Amira A, Ji J. MR Image-Based Attenuation Correction of Brain PET Imaging: Review of Literature on Machine Learning Approaches for Segmentation Journal of Digital Imaging. 33: 1224-1241. PMID 32607906 DOI: 10.1007/S10278-020-00361-X  0.437
2020 Yang M, Ji J, Guo B. Soiling Quantification Using an Image-Based Method: Effects of Imaging Conditions Ieee Journal of Photovoltaics. 1-8. DOI: 10.1109/Jphotov.2020.3018257  0.437
2019 Eslahi SV, Ji J. Accelerated positive contrast MRI of interventional devices using parallel compressed sensing imaging. Magnetic Resonance Imaging. PMID 31028791 DOI: 10.1016/J.Mri.2019.04.006  0.491
2018 Eresen A, Alic L, Birch SM, Friedeck W, Griffin JF, Kornegay JN, Ji JX. Texture as an Imaging Biomarker for Disease Severity in Golden Retriever Muscular Dystrophy. Muscle & Nerve. PMID 30461036 DOI: 10.1002/Mus.26386  0.318
2018 Dhulipala PV, Shi C, Xie G, Wang H, Ji JX. MARBLES - Metal Artifact Based Landmark Enhanced Susceptibility Weighted Imaging For Interventional Device Localization In MRI. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2018: 2611-2614. PMID 30440943 DOI: 10.1109/EMBC.2018.8512739  0.319
2018 Eresen A, Alic L, Kornegay J, Ji JX. Assessment of disease severity in a Canine Model of Duchenne Muscular Dystrophy: Classification of Quantitative MRI. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2018: 648-651. PMID 30440480 DOI: 10.1109/EMBC.2018.8512303  0.306
2018 Eresen A, Birch SM, Alic L, Griffin Iv JF, Kornegay JN, Ji JX. New Similarity Metric for Registration of MRI to Histology: Golden Retriever Muscular Dystrophy Imaging. Ieee Transactions On Bio-Medical Engineering. PMID 30235115 DOI: 10.1109/Tbme.2018.2870711  0.45
2018 Lusher J, Ji J, Orr J. High-Performance Correlation and Mapping Engine for rapid generating brain connectivity networks from big fMRI data Journal of Computational Science. 26: 157-164. DOI: 10.1016/J.Jocs.2018.04.013  0.317
2017 Eslahi SV, Dhulipala PV, Caiyun Shi, Guoxi Xie, Ji JX. Parallel compressive sensing in a hybrid space: Application in interventional MRI. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2017: 3260-3263. PMID 29060593 DOI: 10.1109/EMBC.2017.8037552  0.416
2017 Chang CH, Yu X, Ji JX. Compressed sensing MRI reconstruction from 3D multichannel data using GPUs. Magnetic Resonance in Medicine. PMID 28198568 DOI: 10.1002/Mrm.26636  0.329
2017 Shi C, Xie G, Zhang Y, Zhang X, Chen M, Su S, Dong Y, Liu X, Ji J. Accelerated susceptibility-based positive contrast imaging of MR compatible metallic devices based on modified fast spin echo sequences. Physics in Medicine and Biology. PMID 28182582 DOI: 10.1088/1361-6560/Aa5Fa3  0.37
2017 Chen Z, Ren Y, Su S, Shi C, Ji JX, Zheng H, Liu X, Xie G. Joint Reconstruction of Multi-contrast Images and Multi-channel Coil Sensitivities Applied Magnetic Resonance. 48: 955-969. DOI: 10.1007/S00723-017-0919-4  0.527
2017 Chen Z, Zhang X, Shi C, Su S, Fan Z, Ji JX, Xie G, Liu X. Accelerated 3D Coronary Vessel Wall MR Imaging Based on Compressed Sensing with a Block-Weighted Total Variation Regularization Applied Magnetic Resonance. 48: 361-378. DOI: 10.1007/S00723-017-0866-0  0.441
2015 Griffin JF, Davis MC, Ji JX, Cohen ND, Young BD, Levine JM. Quantitative magnetic resonance imaging in a naturally occurring canine model of spinal cord injury. Spinal Cord. 53: 278-84. PMID 25600310 DOI: 10.1038/Sc.2014.244  0.318
2014 Eresen A, Li P, Ji JX. Correlating 2D histological slice with 3D MRI image volume using smart phone as an interactive tool for muscle study. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2014: 6418-21. PMID 25571465 DOI: 10.1109/EMBC.2014.6945097  0.345
2014 Dong Y, Chang Z, Ji J. Imaging and localizing interventional devices by susceptibility mapping using MRI. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2014: 1541-4. PMID 25570264 DOI: 10.1109/EMBC.2014.6943896  0.311
2014 Dai Z, Ji J, Xiao G, Yan G, Li S, Zhang G, Lin Y, Shen Z, Wu R. Magnetization transfer prepared gradient echo MRI for CEST imaging. Plos One. 9: e112219. PMID 25384020 DOI: 10.1371/Journal.Pone.0112219  0.497
2014 Dong Y, Chang Z, Xie G, Whitehead G, Ji JX. Susceptibility-based positive contrast MRI of brachytherapy seeds. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. PMID 25251865 DOI: 10.1002/Mrm.25453  0.388
2014 Feng S, Ji J. Efficient method to design RF pulses for parallel excitation MRI using gridding and conjugate gradient. Quantitative Imaging in Medicine and Surgery. 4: 87-92. PMID 24834420 DOI: 10.3978/J.Issn.2223-4292.2014.04.09  0.341
2014 Ji JX, Zhang X. Parallel and sparse MR imaging: methods and instruments-Part 2. Quantitative Imaging in Medicine and Surgery. 4: 68-70. PMID 24834417 DOI: 10.3978/J.Issn.2223-4292.2014.04.16  0.484
2014 Chang CH, Ji JX. Improving multi-channel compressed sensing MRI with reweighted l 1 minimization. Quantitative Imaging in Medicine and Surgery. 4: 19-23. PMID 24649431 DOI: 10.3978/J.Issn.2223-4292.2014.03.02  0.478
2014 Zhang X, Ji JX. Parallel and sparse MR imaging: methods and instruments-Part 1. Quantitative Imaging in Medicine and Surgery. 4: 1-3. PMID 24649428 DOI: 10.3978/J.Issn.2223-4292.2014.03.01  0.505
2013 Chang C, Ji JX. Compressed Sensing MRI with Multichannel Data Using GPUs Transactions of Japanese Society For Medical and Biological Engineering. 51. DOI: 10.11239/Jsmbe.51.M-44  0.338
2012 Dong Y, Ji J. Positive contrast MRI of prostate brachytherapy seeds by susceptibility mapping Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Conference. 2012: 392-395. PMID 23365912  0.337
2012 Chang Z, Xiang QS, Shen H, Ji J, Yin FF. Accelerating phase contrast MR angiography by simplified skipped phase encoding and edge deghosting with array coil enhancement. Medical Physics. 39: 1247-52. PMID 22380356 DOI: 10.1118/1.3682000  0.479
2012 Feng S, Ji J. Parallel magnetic resonance imaging using localized receive arrays with sinc interpolation (PILARS). Magnetic Resonance in Medicine. 67: 1114-9. PMID 21858866 DOI: 10.1002/Mrm.23079  0.476
2012 Jiraraksopakun Y, Ji J. A new serial image registration method for contrast-enhanced MRI study. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2005: 1388-91. PMID 17282457 DOI: 10.1109/IEMBS.2005.1616688  0.447
2011 Ji J, Pham V, Zhu XP, Li KL. Parameter estimation in arterial spin labeling MRI: Comparing the four phase model and the buxton model with fourier transform. Quantitative Imaging in Medicine and Surgery. 1: 17-23. PMID 23256050 DOI: 10.3978/J.Issn.2223-4292.2011.11.05  0.369
2011 Ji JX. Compressive sensing imaging with randomized lattice sampling: applications to fast 3D MRI. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2011: 3736-9. PMID 22255152 DOI: 10.1109/IEMBS.2011.6090636  0.389
2011 Feng S, Zhu Y, Ji J. Efficient large-array k-domain parallel MRI using channel-by-channel array reduction. Magnetic Resonance Imaging. 29: 209-15. PMID 20980116 DOI: 10.1016/J.Mri.2010.08.008  0.302
2011 Dong Y, Ji J. Compressive sensing MRI with complex sparsification Proceedings of Spie - the International Society For Optical Engineering. 8138. DOI: 10.1117/12.892030  0.442
2010 Chang CH, Ji J. Compressed sensing MRI with multichannel data using multicore processors Magnetic Resonance in Medicine. 64: 1135-1139. PMID 20564584 DOI: 10.1002/Mrm.22481  0.398
2010 Jiraraksopakun Y, McDougall MP, Wright SM, Ji JX. A flow quantification method using fluid dynamics regularization and MR tagging. Ieee Transactions On Bio-Medical Engineering. 57: 1437-45. PMID 20172815 DOI: 10.1109/Tbme.2009.2038229  0.306
2010 Chang CH, Ji J. Compressed sensing MRI with multi-channel data using multi-core processors. Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual International Conference. 2009: 2684-7. PMID 19964591 DOI: 10.1109/IEMBS.2009.5334095  0.304
2009 Chang Z, Xiang QS, Ji J, Yin FF. Efficient multiple acquisitions by Skipped Phase Encoding and Edge Deghosting (SPEED) using shared spatial information. Magnetic Resonance in Medicine. 61: 229-33. PMID 19097227 DOI: 10.1002/Mrm.21809  0.342
2008 Son JB, Wright SM, Ji JX. Single-point Dixon water-fat imaging using 64-channel single-echo acquisition MRI. Concepts in Magnetic Resonance. Part B, Magnetic Resonance Engineering. 33: 152-162. PMID 31543720 DOI: 10.1002/Cmr.B.20120  0.449
2008 Jiraraksopakun Y, McDougall MP, Wright SM, Ji J. A regularized flow quantification method using MRI tagging and Single Echo Acquisition imaging. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2008: 3397-400. PMID 19163438 DOI: 10.1109/IEMBS.2008.4649935  0.326
2008 Ji JX, Zhao C, Lang T. Compressed sensing parallel magnetic resonance imaging. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2008: 1671-4. PMID 19162999 DOI: 10.1109/IEMBS.2008.4649496  0.43
2008 Nandakumar HP, Ji J. Sparse representation of complex MRI images Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Conference. 398-401. PMID 19162677  0.391
2008 Whitehead G, Chang Z, Ji J. An automated intensity-weighted brachytherapy seed localization algorithm. Medical Physics. 35: 818-827. PMID 18404919 DOI: 10.1118/1.2836418  0.398
2008 Ji JX, Jiraraksopakun Y. Model-based simulation of dynamic magnetic resonance imaging signals Biomedical Signal Processing and Control. 3: 305-311. DOI: 10.1016/J.Bspc.2008.04.004  0.47
2008 Jong BS, Wright SM, Ji JX. Single-point dixon water-fat imaging using 64-channel single echo acquisition MRI Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering. 33: 152-162. DOI: 10.1002/cmr.b.20120  0.362
2007 Zhu X, Ebel A, Ji JX, Schuff N. Spectral phase-corrected GRAPPA reconstruction of three-dimensional echo-planar spectroscopic imaging (3D-EPSI). Magnetic Resonance in Medicine. 57: 815-20. PMID 17457872 DOI: 10.1002/Mrm.21217  0.353
2007 Ji JX, Jong BS, Rane SD. PULSAR: A MATLAB toolbox for parallel magnetic resonance imaging using array coils and multiple channel receivers Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering. 31: 24-36. DOI: 10.1002/Cmr.B.20081  0.478
2006 Son JB, Ji JX. Auto-calibrated dynamic parallel MRI with phase-sensitive data. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 751-4. PMID 17945997 DOI: 10.1109/IEMBS.2006.260695  0.307
2006 Ji JX, Son JB, McDougall MP, Wright SM. Highly accelerated parallel imaging methods for localized massive array coils: Comparison using 64-channel phased-array data 2006 3rd Ieee International Symposium On Biomedical Imaging: From Nano to Macro - Proceedings. 2006: 734-737.  0.356
2005 Xu D, Wiener E, Aref M, Ying L, Ji J, Liang ZP. Integrating parallel imaging with generalized series for accelerated dynamic imaging. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2: 1434-7. PMID 17282469 DOI: 10.1109/IEMBS.2005.1616700  0.613
2005 Ji J, Wright S. Parallel MR Imaging with Accelerations Beyond the Number of Receiver Channels Using Real Image Reconstruction. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 735-8. PMID 17282288 DOI: 10.1109/IEMBS.2005.1616519  0.398
2005 Tsao J, Ji JX, Liang ZP. Interpolation techniques in multimodality image registration and their application Medical Imaging Systems Technology: Analysis and Computational Methods. 255-295. DOI: 10.1142/9789812705785_0008  0.339
2005 Jiraraksopakun Y, Ji JX. A new serial image registration method for contrast-enhanced MRI study Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 7: 1388-1391.  0.448
2005 Ji JX, Wright SM. Parallel MR imaging with accelerations beyond the number of receiver channels using real image reconstruction Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 7: 735-738.  0.399
2004 Garach RM, Ji JX, Ying L, Ma J. Robust phase sensitive inversion recovery imaging using a Markov random field model. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2: 1569-72. PMID 17271998 DOI: 10.1109/IEMBS.2004.1403478  0.374
2004 Son JB, Ji JX, McDougall MP, Wright SM. Adaptive SENSE reconstruction for parallel imaging with massive array coils. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2: 1064-7. PMID 17271866 DOI: 10.1109/IEMBS.2004.1403347  0.406
2003 Ji JX, Pan H, Liang ZP. Further analysis of interpolation effects in mutual information-based image registration. Ieee Transactions On Medical Imaging. 22: 1131-40. PMID 12956268 DOI: 10.1109/Tmi.2003.816957  0.612
Show low-probability matches.