Year |
Citation |
Score |
2024 |
Lombardo J, Castillo E, Castillo R, Miller R, Jones B, Miften M, Kavanagh B, Dicker A, Boyle C, Leiby B, Banks J, Simone NL, Movsas B, Grills I, Guerrero T, et al. Prospective trial of Functional Lung Avoidance Radiation Therapy for Lung Cancer: Quality of Life Report. International Journal of Radiation Oncology, Biology, Physics. PMID 38614278 DOI: 10.1016/j.ijrobp.2024.03.046 |
0.741 |
|
2023 |
Chen Y, Pahlavian SH, Jacobs P, Neupane T, Forghani-Arani F, Castillo E, Castillo R, Vinogradskiy Y. Systematic evaluation of the impact of lung segmentation methods on 4DCT-ventilation imaging using a large patient database. International Journal of Radiation Oncology, Biology, Physics. PMID 37607642 DOI: 10.1016/j.ijrobp.2023.08.017 |
0.649 |
|
2023 |
Ghassemi N, Castillo R, Castillo E, Jones BL, Miften M, Kavanagh B, Werner-Wasik M, Miller R, Barta JA, Grills I, Leiby BE, Guerrero T, Rusthoven CG, Vinogradskiy Y. Evaluation of variables predicting PFT changes for lung cancer patients treated on a prospective 4DCT-ventilation functional avoidance clinical trial. Radiotherapy and Oncology : Journal of the European Society For Therapeutic Radiology and Oncology. 109821. PMID 37516361 DOI: 10.1016/j.radonc.2023.109821 |
0.717 |
|
2023 |
Forghani F, Castillo R, Castillo E, PhD BJ, Rusthoven C, Kwak J, Moiseenko V, Grills I, Miften M, Vinogradskiy Y, Guerrero T. Is individual perfusion dose-response different than ventilation dose-response for lung cancer patients treated with radiotherapy? The British Journal of Radiology. 20220119. PMID 36633096 DOI: 10.1259/bjr.20220119 |
0.698 |
|
2022 |
Miller R, Castillo R, Castillo E, Jones BL, Miften M, Kavanagh B, Lu B, Werner-Wasik M, Ghassemi N, Lombardo J, Barta J, Grills I, Rusthoven CG, Guerrero T, Vinogradskiy Y. Characterizing Pulmonary Function Test Changes for Patients With Lung Cancer Treated on a 2-Institution, 4-Dimensional Computed Tomography-Ventilation Functional Avoidance Prospective Clinical Trial. Advances in Radiation Oncology. 8: 101133. PMID 36618762 DOI: 10.1016/j.adro.2022.101133 |
0.751 |
|
2022 |
Miller R, Santangelo T, Forghani-Arani F, Rusthoven C, Chen Y, Castillo E, Castillo R, Guerrero T, Vinogradskiy Y. Changes in post-treatment cardiac PET avidity predict overall survival in lung cancer patients treated with chemoradiation: secondary analysis of the ACRIN 6668/RTOG 0235 clinical trial. Radiotherapy and Oncology : Journal of the European Society For Therapeutic Radiology and Oncology. PMID 35413391 DOI: 10.1016/j.radonc.2022.04.003 |
0.686 |
|
2022 |
Zakem SJ, Jones B, Castillo R, Castillo E, Miften M, Goodman KA, Schefter T, Olsen J, Vinogradskiy Y. Cardiac metabolic changes on F-positron emission tomography after thoracic radiotherapy predict for overall survival in esophageal cancer patients. Journal of Applied Clinical Medical Physics. e13552. PMID 35243772 DOI: 10.1002/acm2.13552 |
0.533 |
|
2021 |
Vinogradskiy Y, Castillo R, Castillo E, Schubert L, Jones BL, Faught A, Gaspar LE, Kwak J, Bowles DW, Waxweiler T, Dougherty JM, Gao D, Stevens C, Miften M, Kavanagh B, et al. Results of a multi-institutional phase II clinical trial for 4DCT-ventilation functional avoidance thoracic radiotherapy. International Journal of Radiation Oncology, Biology, Physics. PMID 34767934 DOI: 10.1016/j.ijrobp.2021.10.147 |
0.748 |
|
2021 |
Dougherty JM, Castillo E, Castillo R, Faught AM, Pepin M, Park SS, Beltran CJ, Guerrero T, Grills I, Vinogradskiy Y. Functional avoidance-based intensity modulated proton therapy with 4DCT derived ventilation imaging for lung cancer. Journal of Applied Clinical Medical Physics. PMID 34159715 DOI: 10.1002/acm2.13323 |
0.71 |
|
2021 |
Forghani F, Patton T, Kwak J, Thomas D, Diot Q, Rusthoven C, Castillo R, Castillo E, Grills I, Guerrero T, Miften M, Vinogradskiy Y. Characterizing spatial differences between SPECT-ventilation and SPECT-perfusion in patients with lung cancer undergoing radiotherapy. Radiotherapy and Oncology : Journal of the European Society For Therapeutic Radiology and Oncology. PMID 33964328 DOI: 10.1016/j.radonc.2021.04.022 |
0.71 |
|
2021 |
Castillo E, Nair G, Turner-Lawrence D, Myziuk N, Emerson S, Al-Katib S, Westergaard S, Castillo R, Vinogradskiy Y, Quinn T, Guerrero T, Stevens C. Quantifying Pulmonary Perfusion from Non-Contrast Computed Tomography. Medical Physics. PMID 33608933 DOI: 10.1002/mp.14792 |
0.709 |
|
2020 |
Aso S, Navarro-Martin A, Castillo R, Padrones S, Castillo E, Montes A, Martínez JI, Cubero N, López R, Rodríguez L, Palmero R, Manresa F, Guerrero T, Molina M. Severity of radiation pneumonitis, from clinical, dosimetric and biological features: a pilot study. Radiation Oncology (London, England). 15: 246. PMID 33109238 DOI: 10.1186/s13014-020-01694-1 |
0.696 |
|
2020 |
Castillo E, Castillo R, Vinogradskiy Y, Nair G, Grills I, Guerrero T, Stevens C. Technical Note: On the Spatial Correlation Between Robust CT-Ventilation Methods and SPECT Ventilation. Medical Physics. PMID 33007118 DOI: 10.1002/mp.14511 |
0.748 |
|
2020 |
Vinogradskiy Y, Diot Q, Jones B, Castillo R, Castillo E, Kwak J, Bowles D, Grills I, Myziuk N, Guerrero T, Stevens C, Schefter T, Gaspar LE, Kavanagh B, Miften M, et al. Evaluating Positron Emission Tomography-Based Functional Imaging Changes in the Heart After Chemo-Radiation for Patients With Lung Cancer. International Journal of Radiation Oncology, Biology, Physics. PMID 31983558 DOI: 10.1016/J.Ijrobp.2019.12.013 |
0.731 |
|
2019 |
Castillo E, Vinogradskiy Y, Castillo R. Robust HU-based CT ventilation from an integrated mass conservation formulation. Medical Physics. 46: 5036-5046. PMID 31514235 DOI: 10.1002/mp.13817 |
0.65 |
|
2019 |
Castillo E, Castillo R, Vinogradskiy Y, Dougherty M, Solis D, Myziuk N, Thompson A, Guerra R, Nair G, Guerrero T. Robust CT-Ventilation from the Integral Formulation of the Jacobian. Medical Physics. PMID 30779353 DOI: 10.1002/Mp.13453 |
0.725 |
|
2019 |
Zhong Y, Vinogradskiy Y, Chen L, Myziuk N, Castillo R, Castillo E, Guerrero T, Jiang S, Wang J. Technical Note: Deriving ventilation imaging from 4DCT by deep convolutional neural network. Medical Physics. PMID 30714159 DOI: 10.1002/Mp.13421 |
0.711 |
|
2018 |
Pinder-Arabpour A, Jones B, Castillo R, Castillo E, Guerrero T, Goodman K, Schefter T, Kwak J, Miften M, Vinogradskiy Y. Characterizing Spatial Lung Function For Esophageal Cancer Patients Undergoing Radiotherapy. International Journal of Radiation Oncology, Biology, Physics. PMID 30612962 DOI: 10.1016/j.ijrobp.2018.10.024 |
0.718 |
|
2018 |
Vinogradskiy Y, Rusthoven CG, Schubert L, Jones B, Faught A, Castillo R, Castillo E, Gaspar LE, Kwak J, Waxweiler T, Dougherty M, Gao D, Stevens C, Miften M, Kavanagh B, et al. Interim Analysis of a Two-Institution, Prospective Clinical Trial of 4DCT-Ventilation-based Functional Avoidance Radiation Therapy. International Journal of Radiation Oncology, Biology, Physics. 102: 1357-1365. PMID 30353873 DOI: 10.1016/J.Ijrobp.2018.07.186 |
0.707 |
|
2018 |
Vinogradskiy Y, Faught A, Castillo R, Castillo E, Guerrero T, Miften M, Liu AK. Using 4DCT-ventilation to characterize lung function changes for pediatric patients getting thoracic radiotherapy. Journal of Applied Clinical Medical Physics. PMID 29943892 DOI: 10.1002/acm2.12397 |
0.728 |
|
2018 |
Faught AM, Olsen L, Schubert L, Rusthoven C, Castillo E, Castillo R, Zhang J, Guerrero T, Miften M, Vinogradskiy Y. Functional-guided radiotherapy using knowledge-based planning. Radiotherapy and Oncology : Journal of the European Society For Therapeutic Radiology and Oncology. PMID 29628292 DOI: 10.1016/J.Radonc.2018.03.025 |
0.683 |
|
2017 |
Faught AM, Miyasaka Y, Kadoya N, Castillo R, Castillo E, Vinogradskiy Y, Yamamoto T. Evaluating the Toxicity Reduction With Computed Tomographic Ventilation Functional Avoidance Radiation Therapy. International Journal of Radiation Oncology, Biology, Physics. 99: 325-333. PMID 28871982 DOI: 10.1016/j.ijrobp.2017.04.024 |
0.682 |
|
2017 |
Faught AM, Yamamoto T, Castillo R, Castillo E, Zhang J, Miften M, Vinogradskiy Y. Evaluating Which Dose-Function Metrics Are Most Critical for Functional-Guided Radiation Therapy. International Journal of Radiation Oncology, Biology, Physics. 99: 202-209. PMID 28816147 DOI: 10.1016/j.ijrobp.2017.03.051 |
0.635 |
|
2017 |
Waxweiler T, Schubert L, Diot Q, Faught A, Stuhr K, Castillo R, Castillo E, Guerrero T, Rusthoven C, Gaspar L, Kavanagh B, Miften M, Vinogradskiy Y. A complete 4DCT-ventilation functional avoidance virtual trial: Developing strategies for prospective clinical trials. Journal of Applied Clinical Medical Physics. PMID 28436107 DOI: 10.1002/Acm2.12086 |
0.718 |
|
2017 |
Anthony GJ, Cunliffe A, Castillo R, Pham N, Guerrero T, Armato SG, Al-Hallaq H. Incorporation of pre-therapy (18) F-FDG uptake data with CT texture features into a radiomics model for radiation pneumonitis diagnosis. Medical Physics. PMID 28422299 DOI: 10.1002/Mp.12282 |
0.619 |
|
2017 |
Li M, Castillo SJ, Castillo R, Castillo E, Guerrero T, Xiao L, Zheng X. Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model. International Journal of Computer Assisted Radiology and Surgery. PMID 28197760 DOI: 10.1007/s11548-017-1538-0 |
0.79 |
|
2017 |
Vinogradskiy Y, Jackson M, Schubert L, Jones B, Castillo R, Castillo E, Guerrero T, Mitchell J, Rusthoven C, Miften M, Kavanagh B. Assessing the use of 4DCT-ventilation in pre-operative surgical lung cancer evaluation. Medical Physics. 44: 200-208. PMID 28102961 DOI: 10.1002/Mp.12026 |
0.738 |
|
2017 |
Castillo E, Castillo R, Vinogradskiy Y, Guerrero T. The numerical stability of transformation-based CT ventilation. International Journal of Computer Assisted Radiology and Surgery. PMID 28058533 DOI: 10.1007/s11548-016-1509-x |
0.744 |
|
2016 |
Vinogradskiy Y, Schubert L, Diot Q, Waxweiller T, Koo P, Castillo R, Castillo E, Guerrero T, Rusthoven C, Gaspar L, Kavanagh B, Miften M. Regional Lung Function Profiles of Stage I and III Lung Cancer Patients: An Evaluation for Functional Avoidance Radiation Therapy. International Journal of Radiation Oncology, Biology, Physics. 95: 1273-80. PMID 27354134 DOI: 10.1016/J.Ijrobp.2016.02.058 |
0.745 |
|
2015 |
Li M, Xiang Z, Xiao L, Castillo E, Castillo R, Guerrero T. GPU-accelerated Block Matching Algorithm for Deformable Registration of Lung CT Images. ... Proceedings of the ... Ieee International Conference On Progress in Informatics and Computing. Ieee International Conference On Progress in Informatics and Computing. 2015: 292-295. PMID 28042622 DOI: 10.1109/PIC.2015.7489856 |
0.724 |
|
2015 |
Castillo SJ, Castillo R, Castillo E, Pan T, Ibbott G, Balter P, Hobbs B, Guerrero T. Evaluation of 4D CT acquisition methods designed to reduce artifacts. Journal of Applied Clinical Medical Physics / American College of Medical Physics. 16: 4949. PMID 26103169 DOI: 10.1120/Jacmp.V16I2.4949 |
0.786 |
|
2015 |
Brennan D, Schubert L, Diot Q, Castillo R, Castillo E, Guerrero T, Martel MK, Linderman D, Gaspar LE, Miften M, Kavanagh BD, Vinogradskiy Y. Clinical validation of 4-dimensional computed tomography ventilation with pulmonary function test data. International Journal of Radiation Oncology, Biology, Physics. 92: 423-9. PMID 25817531 DOI: 10.1016/J.Ijrobp.2015.01.019 |
0.745 |
|
2015 |
Cunliffe A, Armato SG, Castillo R, Pham N, Guerrero T, Al-Hallaq HA. Lung texture in serial thoracic computed tomography scans: correlation of radiomics-based features with radiation therapy dose and radiation pneumonitis development. International Journal of Radiation Oncology, Biology, Physics. 91: 1048-56. PMID 25670540 DOI: 10.1016/J.Ijrobp.2014.11.030 |
0.594 |
|
2015 |
Castillo R, Pham N, Castillo E, Aso-Gonzalez S, Ansari S, Hobbs B, Palacio D, Skinner H, Guerrero TM. Pre-radiation therapy fluorine 18 fluorodeoxyglucose pet helps identify patients with esophageal cancer at high risk for radiation pneumonitis Radiology. 275: 822-831. PMID 25584706 DOI: 10.1148/Radiol.14140457 |
0.722 |
|
2015 |
Mohamed AS, Ruangskul MN, Awan MJ, Baron CA, Kalpathy-Cramer J, Castillo R, Castillo E, Guerrero TM, Kocak-Uzel E, Yang J, Court LE, Kantor ME, Gunn GB, Colen RR, Frank SJ, et al. Quality assurance assessment of diagnostic and radiation therapy-simulation CT image registration for head and neck radiation therapy: anatomic region of interest-based comparison of rigid and deformable algorithms. Radiology. 274: 752-63. PMID 25380454 DOI: 10.1148/Radiol.14132871 |
0.717 |
|
2014 |
Castillo SJ, Castillo R, Balter P, Pan T, Ibbott G, Hobbs B, Yuan Y, Guerrero T. Assessment of a quantitative metric for 4D CT artifact evaluation by observer consensus. Journal of Applied Clinical Medical Physics / American College of Medical Physics. 15: 4718. PMID 24892346 DOI: 10.1120/Jacmp.V15I3.4718 |
0.784 |
|
2014 |
Vinogradskiy Y, Koo PJ, Castillo R, Castillo E, Guerrero T, Gaspar LE, Miften M, Kavanagh BD. Comparison of 4-dimensional computed tomography ventilation with nuclear medicine ventilation-perfusion imaging: a clinical validation study. International Journal of Radiation Oncology, Biology, Physics. 89: 199-205. PMID 24725702 DOI: 10.1016/j.ijrobp.2014.01.009 |
0.777 |
|
2014 |
Castillo E, Castillo R, Fuentes D, Guerrero T. Computing global minimizers to a constrained B-spline image registration problem from optimal l1 perturbations to block match data. Medical Physics. 41: 041904. PMID 24694135 DOI: 10.1118/1.4866891 |
0.739 |
|
2014 |
Castillo R, Pham N, Ansari S, Meshkov D, Castillo S, Li M, Olanrewaju A, Hobbs B, Castillo E, Guerrero T. Pre-radiotherapy FDG PET predicts radiation pneumonitis in lung cancer. Radiation Oncology (London, England). 9: 74. PMID 24625207 DOI: 10.1186/1748-717X-9-74 |
0.801 |
|
2014 |
Liu S, Yuan Y, Castillo R, Guerrero T, Johnson VE. Evaluation of image registration spatial accuracy using a Bayesian hierarchical model. Biometrics. 70: 366-77. PMID 24575781 DOI: 10.1111/Biom.12146 |
0.603 |
|
2014 |
Li M, Castillo E, Luo HY, Zheng XL, Castillo R, Meshkov D, Guerrero T. Deformable image registration for temporal subtraction of chest radiographs. International Journal of Computer Assisted Radiology and Surgery. 9: 513-22. PMID 24078349 DOI: 10.1007/s11548-013-0947-y |
0.695 |
|
2014 |
Li M, Castillo E, Zheng XL, Luo HY, Castillo R, Wu Y, Guerrero T. Modeling lung deformation: a combined deformable image registration method with spatially varying Young's modulus estimates. Medical Physics. 40: 081902. PMID 23927316 DOI: 10.1118/1.4812419 |
0.717 |
|
2013 |
McCurdy M, Bergsma DP, Hyun E, Kim T, Choi E, Castillo R, Castillo E, Guerrero T. The Role of Lung Lobes in Radiation Pneumonitis and Radiation-Induced Inflammation in the Lung: A Retrospective Study. Journal of Radiation Oncology. 2: 203-208. PMID 23828730 DOI: 10.1007/s13566-012-0079-y |
0.707 |
|
2013 |
Castillo R, Castillo E, Fuentes D, Ahmad M, Wood AM, Ludwig MS, Guerrero T. A reference dataset for deformable image registration spatial accuracy evaluation using the COPDgene study archive. Physics in Medicine and Biology. 58: 2861-77. PMID 23571679 DOI: 10.1088/0031-9155/58/9/2861 |
0.785 |
|
2013 |
Vinogradskiy Y, Castillo R, Castillo E, Tucker SL, Liao Z, Guerrero T, Martel MK. Use of 4-dimensional computed tomography-based ventilation imaging to correlate lung dose and function with clinical outcomes. International Journal of Radiation Oncology, Biology, Physics. 86: 366-71. PMID 23474113 DOI: 10.1016/J.Ijrobp.2013.01.004 |
0.783 |
|
2013 |
Echeverria AE, McCurdy M, Castillo R, Bernard V, Ramos NV, Buckley W, Castillo E, Liu P, Martinez J, Guerrero T. Proton therapy radiation pneumonitis local dose-response in esophagus cancer patients. Radiotherapy and Oncology : Journal of the European Society For Therapeutic Radiology and Oncology. 106: 124-9. PMID 23127772 DOI: 10.1016/j.radonc.2012.09.003 |
0.664 |
|
2012 |
Mathew L, Wheatley A, Castillo R, Castillo E, Rodrigues G, Guerrero T, Parraga G. Hyperpolarized (3)He magnetic resonance imaging: comparison with four-dimensional x-ray computed tomography imaging in lung cancer. Academic Radiology. 19: 1546-53. PMID 22999648 DOI: 10.1016/j.acra.2012.08.007 |
0.738 |
|
2012 |
Castillo E, Castillo R, White B, Rojo J, Guerrero T. Least median of squares filtering of locally optimal point matches for compressible flow image registration. Physics in Medicine and Biology. 57: 4827-33. PMID 22797602 DOI: 10.1088/0031-9155/57/15/4827 |
0.682 |
|
2012 |
McCurdy MR, Castillo R, Martinez J, Al Hallack MN, Lichter J, Zouain N, Guerrero T. [18F]-FDG uptake dose-response correlates with radiation pneumonitis in lung cancer patients. Radiotherapy and Oncology : Journal of the European Society For Therapeutic Radiology and Oncology. 104: 52-7. PMID 22578806 DOI: 10.1016/j.radonc.2012.04.003 |
0.595 |
|
2012 |
Castillo R, Castillo E, McCurdy M, Gomez DR, Block AM, Bergsma D, Joy S, Guerrero T. Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis. Physics in Medicine and Biology. 57: 1855-71. PMID 22411124 DOI: 10.1088/0031-9155/57/7/1855 |
0.752 |
|
2012 |
Vinogradskiy YY, Castillo R, Castillo E, Chandler A, Martel MK, Guerrero T. Use of weekly 4DCT-based ventilation maps to quantify changes in lung function for patients undergoing radiation therapy. Medical Physics. 39: 289-98. PMID 22225299 DOI: 10.1118/1.3668056 |
0.727 |
|
2010 |
Castillo R, Castillo E, Martinez J, Guerrero T. Ventilation from four-dimensional computed tomography: density versus Jacobian methods. Physics in Medicine and Biology. 55: 4661-85. PMID 20671351 DOI: 10.1088/0031-9155/55/16/004 |
0.754 |
|
2010 |
Gu X, Pan H, Liang Y, Castillo R, Yang D, Choi D, Castillo E, Majumdar A, Guerrero T, Jiang SB. Implementation and evaluation of various demons deformable image registration algorithms on a GPU. Physics in Medicine and Biology. 55: 207-19. PMID 20009197 DOI: 10.1088/0031-9155/55/1/012 |
0.719 |
|
2010 |
Castillo E, Castillo R, Martinez J, Shenoy M, Guerrero T. Four-dimensional deformable image registration using trajectory modeling. Physics in Medicine and Biology. 55: 305-27. PMID 20009196 DOI: 10.1088/0031-9155/55/1/018 |
0.698 |
|
2009 |
Castillo R, Castillo E, Guerra R, Johnson VE, McPhail T, Garg AK, Guerrero T. A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets. Physics in Medicine and Biology. 54: 1849-70. PMID 19265208 DOI: 10.1088/0031-9155/54/7/001 |
0.646 |
|
2007 |
Guerrero T, Castillo R, Noyola-Martinez J, Torres M, Zhou X, Guerra R, Cody D, Komaki R, Travis E. Reduction of pulmonary compliance found with high-resolution computed tomography in irradiated mice. International Journal of Radiation Oncology, Biology, Physics. 67: 879-87. PMID 17293238 DOI: 10.1016/J.Ijrobp.2006.10.037 |
0.644 |
|
2006 |
Guerrero T, Castillo R, Sanders K, Price R, Komaki R, Cody D. Novel method to calculate pulmonary compliance images in rodents from computed tomography acquired at constant pressures. Physics in Medicine and Biology. 51: 1101-12. PMID 16481680 DOI: 10.1088/0031-9155/51/5/003 |
0.677 |
|
2005 |
Pan T, Mawlawi O, Nehmeh SA, Erdi YE, Luo D, Liu HH, Castillo R, Mohan R, Liao Z, Macapinlac HA. Attenuation correction of PET images with respiration-averaged CT images in PET/CT. Journal of Nuclear Medicine : Official Publication, Society of Nuclear Medicine. 46: 1481-7. PMID 16157531 |
0.35 |
|
Show low-probability matches. |