John Pauly - Publications

Affiliations: 
Stanford University, Palo Alto, CA 
Area:
Electrical Engineering

202 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2023 Dwork N, O'Connor D, Johnson EMI, Baron CA, Gordon JW, Pauly JM, Larson PEZ. Optimization in the space domain for density compensation with the nonuniform FFT. Magnetic Resonance Imaging. PMID 36934830 DOI: 10.1016/j.mri.2023.03.003  0.314
2022 Ong F, Zhong Z, Liao C, Lustig M, Vasanawala SS, Pauly JM. SLfRank: Shinnar-Le-Roux Pulse Design with Reduced Energy and Accurate Phase Profiles using Rank Factorization. Ieee Transactions On Medical Imaging. PMID 37015710 DOI: 10.1109/TMI.2022.3231782  0.52
2022 Wu Y, Alley M, Li Z, Datta K, Wen Z, Sandino C, Syed A, Ren H, Xing L, Lustig M, Pauly J, Vasanawala S. Deep Learning-Based Water-Fat Separation from Dual-Echo Chemical Shift-Encoded Imaging. Bioengineering (Basel, Switzerland). 9. PMID 36290546 DOI: 10.3390/bioengineering9100579  0.59
2022 Shen L, Zhao W, Capaldi D, Pauly J, Xing L. A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstruction. Computers in Biology and Medicine. 105710. PMID 35715260 DOI: 10.1016/j.compbiomed.2022.105710  0.344
2022 Shen L, Pauly J, Xing L. NeRP: Implicit Neural Representation Learning With Prior Embedding for Sparsely Sampled Image Reconstruction. Ieee Transactions On Neural Networks and Learning Systems. PMID 35657845 DOI: 10.1109/TNNLS.2022.3177134  0.359
2022 Lei K, Syed AB, Zhu X, Pauly JM, Vasanawala SS. Artifact- and content-specific quality assessment for MRI with image rulers. Medical Image Analysis. 77: 102344. PMID 35091278 DOI: 10.1016/j.media.2021.102344  0.324
2020 Shen L, Zhu W, Wang X, Xing L, Pauly JM, Turkbey B, Harmon SA, Sanford TH, Mehralivand S, Choyke P, Wood BJ, Xu D. Multi-Domain Image Completion for Random Missing Input Data. Ieee Transactions On Medical Imaging. PMID 33351753 DOI: 10.1109/TMI.2020.3046444  0.31
2020 Ma JJ, Nakarmi U, Kin CYS, Sandino CM, Cheng JY, Syed AB, Wei P, Pauly JM, Vasanawala SS. DIAGNOSTIC IMAGE QUALITY ASSESSMENT AND CLASSIFICATION IN MEDICAL IMAGING: OPPORTUNITIES AND CHALLENGES. Proceedings. Ieee International Symposium On Biomedical Imaging. 2020: 337-340. PMID 33274013 DOI: 10.1109/isbi45749.2020.9098735  0.338
2020 Lei K, Mardani M, Pauly JM, Vasanawala SS. Wasserstein GANs for MR Imaging: from Paired to Unpaired Training. Ieee Transactions On Medical Imaging. PMID 32915728 DOI: 10.1109/Tmi.2020.3022968  0.31
2020 Stumpf K, Kaye E, Paul J, Wundrak S, Pauly JM, Rasche V. Two-dimensional UTE overview imaging for dental application. Magnetic Resonance in Medicine. PMID 32390153 DOI: 10.1002/mrm.28312  0.303
2020 Wang G, Gong E, Banerjee S, Martin D, Tong E, Choi J, Chen H, Wintermark M, Pauly JM, Zaharchuk G. Synthesize High-quality Multi-contrast Magnetic Resonance Imaging from Multi-echo Acquisition Using Multi-task Deep Generative Model. Ieee Transactions On Medical Imaging. PMID 32286966 DOI: 10.1109/Tmi.2020.2987026  0.32
2019 Byron K, Winkler SA, Robb F, Vasanawala S, Pauly J, Scott G. An MRI Compatible RF MEMs Controlled Wireless Power Transfer System. Ieee Transactions On Microwave Theory and Techniques. 67: 1717-1726. PMID 31423023 DOI: 10.1109/Tmtt.2019.2902554  0.39
2019 Ouyang J, Chen KT, Gong E, Pauly J, Zaharchuk G. Ultra-low-dose PET Reconstruction using Generative Adversarial Network with Feature Matching and Task-Specific Perceptual Loss. Medical Physics. PMID 31131901 DOI: 10.1002/Mp.13626  0.303
2019 Zeng DY, Shaikh J, Holmes S, Brunsing RL, Pauly JM, Nishimura DG, Vasanawala SS, Cheng JY. Deep residual network for off-resonance artifact correction with application to pediatric body MRA with 3D cones. Magnetic Resonance in Medicine. PMID 31115936 DOI: 10.1002/Mrm.27825  0.572
2019 Winkler SA, Corea J, Lechêne B, O'Brien K, Bonanni JR, Chaudhari A, Alley M, Taviani V, Grafendorfer T, Robb F, Scott G, Pauly J, Lustig M, Arias AC, Vasanawala S. Evaluation of a Flexible 12-Channel Screen-printed Pediatric MRI Coil. Radiology. 181883. PMID 30806599 DOI: 10.1148/Radiol.2019181883  0.566
2018 Mardani M, Gong E, Cheng JY, Vasanawala SS, Zaharchuk G, Xing L, Pauly JM. Deep Generative Adversarial Neural Networks for Compressive Sensing (GANCS) MRI. Ieee Transactions On Medical Imaging. PMID 30040634 DOI: 10.1109/Tmi.2018.2858752  0.344
2018 Chen F, Taviani V, Malkiel I, Cheng JY, Tamir JI, Shaikh J, Chang ST, Hardy CJ, Pauly JM, Vasanawala SS. Variable-Density Single-Shot Fast Spin-Echo MRI with Deep Learning Reconstruction by Using Variational Networks. Radiology. 180445. PMID 30040039 DOI: 10.1148/Radiol.2018180445  0.357
2017 Gibbons EK, Vasanawala SS, Pauly JM, Kerr AB. Body diffusion-weighted imaging using magnetization prepared single-shot fast spin echo and extended parallel imaging signal averaging. Magnetic Resonance in Medicine. PMID 29044721 DOI: 10.1002/Mrm.26971  0.348
2017 Baron CA, Dwork N, Pauly JM, Nishimura DG. Rapid compressed sensing reconstruction of 3D non-Cartesian MRI. Magnetic Resonance in Medicine. PMID 28940748 DOI: 10.1002/Mrm.26928  0.531
2017 Chen F, Taviani V, Tamir JI, Cheng JY, Zhang T, Song Q, Hargreaves BA, Pauly JM, Vasanawala SS. Self-Calibrating Wave-Encoded Variable-Density Single-Shot Fast Spin Echo Imaging. Journal of Magnetic Resonance Imaging : Jmri. PMID 28906567 DOI: 10.1002/Jmri.25853  0.308
2017 Gibbons EK, Roux PL, Vasanawala SS, Pauly JM, Kerr AB. Robust Self-Calibrating nCPMG Acquisition: Application to Body Diffusion-Weighted Imaging. Ieee Transactions On Medical Imaging. PMID 28829307 DOI: 10.1109/Tmi.2017.2741421  0.334
2017 Cheng JY, Zhang T, Alley MT, Uecker M, Lustig M, Pauly JM, Vasanawala SS. Comprehensive Multi-Dimensional MRI for the Simultaneous Assessment of Cardiopulmonary Anatomy and Physiology. Scientific Reports. 7: 5330. PMID 28706270 DOI: 10.1038/S41598-017-04676-8  0.559
2017 Dwork N, Lasry EM, Pauly JM, Balbás J. Formulation of image fusion as a constrained least squares optimization problem. Journal of Medical Imaging (Bellingham, Wash.). 4: 014003. PMID 28331885 DOI: 10.1117/1.JMI.4.1.014003  0.339
2016 Gibbons E, Le Roux P, Vasanawala S, Pauly J, Kerr A. Body diffusion weighted imaging using non-CPMG fast spin echo. Ieee Transactions On Medical Imaging. PMID 27810802 DOI: 10.1109/Tmi.2016.2622238  0.418
2016 Shang H, Sukumar S, von Morze C, Bok RA, Marco-Rius I, Kerr A, Reed GD, Milshteyn E, Ohliger MA, Kurhanewicz J, Larson PE, Pauly JM, Vigneron DB. Spectrally selective three-dimensional dynamic balanced steady-state free precession for hyperpolarized C-13 metabolic imaging with spectrally selective radiofrequency pulses. Magnetic Resonance in Medicine. PMID 27770458 DOI: 10.1002/Mrm.26480  0.378
2016 Zhang T, Chen Y, Bao S, Alley MT, Pauly JM, Hargreaves BA, Vasanawala SS. Resolving phase ambiguity in dual-echo dixon imaging using a projected power method. Magnetic Resonance in Medicine. PMID 27221766 DOI: 10.1002/Mrm.26287  0.329
2016 Zhu K, Dougherty R, Wu H, Middione M, Takahashi A, Zhang T, Pauly J, Kerr A. Hybrid-Space SENSE Reconstruction for Simultaneous Multi-Slice MRI. Ieee Transactions On Medical Imaging. PMID 26915118 DOI: 10.1109/Tmi.2016.2531635  0.414
2016 Shang H, Larson PE, Kerr A, Reed G, Sukumar S, Elkhaled A, Gordon JW, Ohliger MA, Pauly JM, Lustig M, Vigneron DB. Multiband RF pulses with improved performance via convex optimization. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 262: 81-90. PMID 26754063 DOI: 10.1016/J.Jmr.2015.11.010  0.544
2016 Cheng JY, Zhang T, Pauly JM, Vasanawala S. Feasibility of ultra-high-dimensional flow imaging for rapid pediatric cardiopulmonary MRI Journal of Cardiovascular Magnetic Resonance. 18. DOI: 10.1186/1532-429X-18-S1-P217  0.337
2015 Feng Y, Gordon JW, Shin PJ, von Morze C, Lustig M, Larson PE, Ohliger MA, Carvajal L, Tropp J, Pauly JM, Vigneron DB. Development and testing of hyperpolarized (13)C MR calibrationless parallel imaging. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 262: 1-7. PMID 26679288 DOI: 10.1016/J.Jmr.2015.10.018  0.605
2015 Cheng JY, Hanneman K, Zhang T, Alley MT, Lai P, Tamir JI, Uecker M, Pauly JM, Lustig M, Vasanawala SS. Comprehensive motion-compensated highly accelerated 4D flow MRI with ferumoxytol enhancement for pediatric congenital heart disease. Journal of Magnetic Resonance Imaging : Jmri. PMID 26646061 DOI: 10.1002/Jmri.25106  0.484
2015 Zhang T, Grafendorfer T, Cheng JY, Ning P, Rainey B, Giancola M, Ortman S, Robb FJ, Calderon PD, Hargreaves BA, Lustig M, Scott GC, Pauly JM, Vasanawala SS. A semiflexible 64-channel receive-only phased array for pediatric body MRI at 3T. Magnetic Resonance in Medicine. PMID 26418283 DOI: 10.1002/Mrm.25999  0.468
2015 Zhang T, Cheng JY, Chen Y, Nishimura DG, Pauly JM, Vasanawala SS. Robust self-navigated body MRI using dense coil arrays. Magnetic Resonance in Medicine. PMID 26220204 DOI: 10.1002/Mrm.25858  0.492
2015 Zhang T, Yousaf U, Hsiao A, Cheng JY, Alley MT, Lustig M, Pauly JM, Vasanawala SS. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography. Pediatric Radiology. PMID 26040509 DOI: 10.1007/S00247-015-3384-Y  0.537
2015 Cheng JY, Zhang T, Ruangwattanapaisarn N, Alley MT, Uecker M, Pauly JM, Lustig M, Vasanawala SS. Free-breathing pediatric MRI with nonrigid motion correction and acceleration. Journal of Magnetic Resonance Imaging : Jmri. 42: 407-20. PMID 25329325 DOI: 10.1002/Jmri.24785  0.563
2015 Zhang T, Cheng JY, Potnick AG, Barth RA, Alley MT, Uecker M, Lustig M, Pauly JM, Vasanawala SS. Fast pediatric 3D free-breathing abdominal dynamic contrast enhanced MRI with high spatiotemporal resolution. Journal of Magnetic Resonance Imaging : Jmri. 41: 460-73. PMID 24375859 DOI: 10.1002/Jmri.24551  0.578
2014 Shin PJ, Larson PE, Uecker M, Reed GD, Kerr AB, Tropp J, Ohliger MA, Nelson SJ, Pauly JM, Lustig M, Vigneron DB. Chemical shift separation with controlled aliasing for hyperpolarized (13) C metabolic imaging. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. PMID 25298086 DOI: 10.1002/Mrm.25473  0.596
2014 Shin PJ, Larson PE, Ohliger MA, Elad M, Pauly JM, Vigneron DB, Lustig M. Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion. Magnetic Resonance in Medicine. 72: 959-70. PMID 24248734 DOI: 10.1002/Mrm.24997  0.576
2014 Zhang T, Chowdhury S, Lustig M, Barth RA, Alley MT, Grafendorfer T, Calderon PD, Robb FJ, Pauly JM, Vasanawala SS. Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction. Journal of Magnetic Resonance Imaging : Jmri. 40: 13-25. PMID 24127123 DOI: 10.1002/Jmri.24333  0.612
2014 Zun Z, Hargreaves BA, Pauly J, Zaharchuk G. Near-contiguous spin echo imaging using matched-phase RF and its application in velocity-selective arterial spin labeling. Magnetic Resonance in Medicine. 71: 2043-50. PMID 23857667 DOI: 10.1002/Mrm.24866  0.749
2014 Uecker M, Lai P, Murphy MJ, Virtue P, Elad M, Pauly JM, Vasanawala SS, Lustig M. ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA. Magnetic Resonance in Medicine. 71: 990-1001. PMID 23649942 DOI: 10.1002/Mrm.24751  0.579
2014 Balchandani P, Glover G, Pauly J, Spielman D. Improved slice-selective adiabatic excitation. Magnetic Resonance in Medicine. 71: 75-82. PMID 23401184 DOI: 10.1002/Mrm.24630  0.353
2013 Zhang T, Pauly JM, Vasanawala SS, Lustig M. Coil compression for accelerated imaging with Cartesian sampling. Magnetic Resonance in Medicine. 69: 571-82. PMID 22488589 DOI: 10.1002/Mrm.24267  0.589
2012 Reed GD, Larson PE, Morze Cv, Bok R, Lustig M, Kerr AB, Pauly JM, Kurhanewicz J, Vigneron DB. A method for simultaneous echo planar imaging of hyperpolarized ¹³C pyruvate and ¹³C lactate. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 217: 41-7. PMID 22405760 DOI: 10.1016/J.Jmr.2012.02.008  0.633
2012 Cheng JY, Alley MT, Cunningham CH, Vasanawala SS, Pauly JM, Lustig M. Nonrigid motion correction in 3D using autofocusing with localized linear translations. Magnetic Resonance in Medicine. 68: 1785-97. PMID 22307933 DOI: 10.1002/mrm.24189  0.482
2012 Lee D, Grissom WA, Lustig M, Kerr AB, Stang PP, Pauly JM. VERSE-guided numerical RF pulse design: a fast method for peak RF power control. Magnetic Resonance in Medicine. 67: 353-62. PMID 22135085 DOI: 10.1002/Mrm.23010  0.52
2012 Stang PP, Conolly SM, Santos JM, Pauly JM, Scott GC. Medusa: a scalable MR console using USB. Ieee Transactions On Medical Imaging. 31: 370-9. PMID 21954200 DOI: 10.1109/TMI.2011.2169681  0.612
2012 Balchandani P, Khalighi MM, Glover G, Pauly J, Spielman D. Self-refocused adiabatic pulse for spin echo imaging at 7 T. Magnetic Resonance in Medicine. 67: 1077-85. PMID 21954048 DOI: 10.1002/Mrm.23089  0.384
2012 Shultz K, Stang P, Kerr A, Pauly J, Scott G. RF field visualization of RF ablation at the Larmor frequency. Ieee Transactions On Medical Imaging. 31: 938-47. PMID 21775256 DOI: 10.1109/Tmi.2011.2162248  0.344
2012 Nishimura DG, Macovski A, Pauly JM. Magnetic resonance angiography. Ieee Transactions On Medical Imaging. 5: 140-51. PMID 18244000 DOI: 10.1109/Tmi.1986.4307763  0.757
2011 Vasanawala S, Murphy M, Alley M, Lai P, Keutzer K, Pauly J, Lustig M. PRACTICAL PARALLEL IMAGING COMPRESSED SENSING MRI: SUMMARY OF TWO YEARS OF EXPERIENCE IN ACCELERATING BODY MRI OF PEDIATRIC PATIENTS. Proceedings / Ieee International Symposium On Biomedical Imaging: From Nano to Macro. Ieee International Symposium On Biomedical Imaging. 2011: 1039-1043. PMID 24443670 DOI: 10.1109/ISBI.2011.5872579  0.612
2011 Pauly J, Nishimura D, Macovski A. A k-space analysis of small-tip-angle excitation. 1989. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 213: 544-57. PMID 22152370 DOI: 10.1016/J.Jmr.2011.09.023  0.676
2011 Pauly JM, Nishimura DG, Macovski A. Introduction to: A k-space analysis of small-tip-angle excitation. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 213: 558-9. PMID 21890389 DOI: 10.1016/J.Jmr.2011.08.008  0.65
2011 Hargreaves BA, Worters PW, Pauly KB, Pauly JM, Koch KM, Gold GE. Metal-induced artifacts in MRI. Ajr. American Journal of Roentgenology. 197: 547-55. PMID 21862795 DOI: 10.2214/Ajr.11.7364  0.395
2011 Stikov N, Keenan KE, Pauly JM, Smith RL, Dougherty RF, Gold GE. Cross-relaxation imaging of human articular cartilage. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 66: 725-34. PMID 21416504 DOI: 10.1002/Mrm.22865  0.692
2011 Cheng JY, Santos JM, Pauly JM. Fast concomitant gradient field and field inhomogeneity correction for spiral cardiac imaging. Magnetic Resonance in Medicine. 66: 390-401. PMID 21384423 DOI: 10.1002/mrm.22802  0.351
2011 Zanchi MG, Stang P, Kerr A, Pauly JM, Scott GC. Frequency-offset Cartesian feedback for MRI power amplifier linearization. Ieee Transactions On Medical Imaging. 30: 512-22. PMID 20959264 DOI: 10.1109/TMI.2010.2087768  0.314
2011 Larson PE, Hu S, Lustig M, Kerr AB, Nelson SJ, Kurhanewicz J, Pauly JM, Vigneron DB. Fast dynamic 3D MR spectroscopic imaging with compressed sensing and multiband excitation pulses for hyperpolarized 13C studies. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 65: 610-9. PMID 20939089 DOI: 10.1002/Mrm.22650  0.625
2011 Stikov N, Perry LM, Mezer A, Rykhlevskaia E, Wandell BA, Pauly JM, Dougherty RF. Bound pool fractions complement diffusion measures to describe white matter micro and macrostructure. Neuroimage. 54: 1112-21. PMID 20828622 DOI: 10.1016/J.Neuroimage.2010.08.068  0.648
2010 Doneva M, Börnert P, Eggers H, Mertins A, Pauly J, Lustig M. Compressed sensing for chemical shift-based water-fat separation. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 64: 1749-59. PMID 20859998 DOI: 10.1002/Mrm.22563  0.589
2010 Balchandani P, Pauly J, Spielman D. Designing adiabatic radio frequency pulses using the Shinnar-Le Roux algorithm. Magnetic Resonance in Medicine. 64: 843-51. PMID 20806378 DOI: 10.1002/Mrm.22473  0.381
2010 Sussman MS, Vidarsson L, Pauly JM, Cheng HL. A technique for rapid single-echo spin-echo T2 mapping. Magnetic Resonance in Medicine. 64: 536-45. PMID 20665797 DOI: 10.1002/Mrm.22454  0.733
2010 Lustig M, Pauly JM. SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space. Magnetic Resonance in Medicine. 64: 457-71. PMID 20665790 DOI: 10.1002/Mrm.22428  0.592
2010 Grissom WA, Lustig M, Holbrook AB, Rieke V, Pauly JM, Butts-Pauly K. Reweighted ℓ1 referenceless PRF shift thermometry. Magnetic Resonance in Medicine. 64: 1068-77. PMID 20564600 DOI: 10.1002/Mrm.22502  0.594
2010 Vasanawala SS, Alley MT, Hargreaves BA, Barth RA, Pauly JM, Lustig M. Improved pediatric MR imaging with compressed sensing. Radiology. 256: 607-16. PMID 20529991 DOI: 10.1148/Radiol.10091218  0.645
2010 Hargreaves BA, Chen W, Lu W, Alley MT, Gold GE, Brau AC, Pauly JM, Pauly KB. Accelerated slice encoding for metal artifact correction. Journal of Magnetic Resonance Imaging : Jmri. 31: 987-96. PMID 20373445 DOI: 10.1002/Jmri.22112  0.382
2010 Cukur T, Santos JM, Pauly JM, Nishimura DG. Variable-density parallel imaging with partially localized coil sensitivities. Ieee Transactions On Medical Imaging. 29: 1173-81. PMID 20236876 DOI: 10.1109/Tmi.2010.2042805  0.613
2010 Larson PE, Bok R, Kerr AB, Lustig M, Hu S, Chen AP, Nelson SJ, Pauly JM, Kurhanewicz J, Vigneron DB. Investigation of tumor hyperpolarized [1-13C]-pyruvate dynamics using time-resolved multiband RF excitation echo-planar MRSI. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 63: 582-91. PMID 20187172 DOI: 10.1002/Mrm.22264  0.51
2010 Hu S, Lustig M, Balakrishnan A, Larson PE, Bok R, Kurhanewicz J, Nelson SJ, Goga A, Pauly JM, Vigneron DB. 3D compressed sensing for highly accelerated hyperpolarized (13)C MRSI with in vivo applications to transgenic mouse models of cancer. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 63: 312-21. PMID 20017160 DOI: 10.1002/Mrm.22233  0.6
2010 Zanchi MG, Venook R, Pauly JM, Scott GC. An optically coupled system for quantitative monitoring of MRI-induced RF currents into long conductors. Ieee Transactions On Medical Imaging. 29: 169-78. PMID 19758855 DOI: 10.1109/Tmi.2009.2031558  0.753
2009 Grissom WA, Kerr AB, Holbrook AB, Pauly JM, Butts-Pauly K. Maximum linear-phase spectral-spatial radiofrequency pulses for fat-suppressed proton resonance frequency-shift MR Thermometry. Magnetic Resonance in Medicine. 62: 1242-50. PMID 19780177 DOI: 10.1002/Mrm.22118  0.301
2009 Sümbül U, Santos JM, Pauly JM. A practical acceleration algorithm for real-time imaging. Ieee Transactions On Medical Imaging. 28: 2042-51. PMID 19709964 DOI: 10.1109/Tmi.2009.2030474  0.776
2009 Balchandani P, Yamada M, Pauly J, Yang P, Spielman D. Self-refocused spatial-spectral pulse for positive contrast imaging of cells labeled with SPIO nanoparticles. Magnetic Resonance in Medicine. 62: 183-92. PMID 19449385 DOI: 10.1002/Mrm.21973  0.442
2009 Lee D, Lustig M, Grissom WA, Pauly JM. Time-optimal design for multidimensional and parallel transmit variable-rate selective excitation. Magnetic Resonance in Medicine. 61: 1471-9. PMID 19365849 DOI: 10.1002/Mrm.21950  0.538
2009 Josan S, Kaye E, Pauly JM, Daniel BL, Pauly KB. Improved half RF slice selectivity in the presence of eddy currents with out-of-slice saturation. Magnetic Resonance in Medicine. 61: 1090-5. PMID 19319972 DOI: 10.1002/Mrm.21914  0.357
2009 Lee J, Lustig M, Kim DH, Pauly JM. Improved shim method based on the minimization of the maximum off-resonance frequency for balanced steady-state free precession (bSSFP). Magnetic Resonance in Medicine. 61: 1500-6. PMID 19319895 DOI: 10.1002/Mrm.21800  0.565
2009 Josan S, Pauly JM, Daniel BL, Pauly KB. Double half RF pulses for reduced sensitivity to eddy currents in UTE imaging. Magnetic Resonance in Medicine. 61: 1083-9. PMID 19235919 DOI: 10.1002/mrm.21879  0.325
2009 Sümbül U, Santos JM, Pauly JM. Improved time series reconstruction for dynamic magnetic resonance imaging. Ieee Transactions On Medical Imaging. 28: 1093-104. PMID 19150785 DOI: 10.1109/Tmi.2008.2012030  0.804
2009 Osorio JA, Xu D, Cunningham CH, Chen A, Kerr AB, Pauly JM, Vigneron DB, Nelson SJ. Design of cosine modulated very selective suppression pulses for MR spectroscopic imaging at 3T. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 61: 533-40. PMID 19097232 DOI: 10.1002/Mrm.21842  0.312
2009 Nguyen PK, Scott G, Engvall J, Santos JM, McConnell MV, Wright G, Nishimura DG, Pauly JM, Hu BS, Yang PC. A Two Element Phased Array Coil Enabling Widespread Application of High Resolution MR Coronary Angiography The Open Cardiovascular Imaging Journal. 1: 30-38. DOI: 10.2174/1876538600901010030  0.564
2009 Swaminathan A, Rieke V, King RL, Pauly J, Butts-Pauly K, McConnell M. Feasibility of noninvasive 3 T MRI-guided myocardial ablation with high intensity focused ultrasound Journal of Cardiovascular Magnetic Resonance. 11: 1-316. DOI: 10.1186/1532-429X-11-S1-O86  0.335
2009 Grissom W, Pauly KB, Lustig M, Rieke V, Pauly J, McDannold N. Regularized referenceless temperature estimation in prf-shift mr thermometry Proceedings - 2009 Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Isbi 2009. 1235-1238. DOI: 10.1109/ISBI.2009.5193285  0.494
2008 Larson PE, Kerr AB, Chen AP, Lustig MS, Zierhut ML, Hu S, Cunningham CH, Pauly JM, Kurhanewicz J, Vigneron DB. Multiband excitation pulses for hyperpolarized 13C dynamic chemical-shift imaging. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 194: 121-7. PMID 18619875 DOI: 10.1016/J.Jmr.2008.06.010  0.585
2008 Lustig M, Kim SJ, Pauly JM. A fast method for designing time-optimal gradient waveforms for arbitrary k-space trajectories. Ieee Transactions On Medical Imaging. 27: 866-73. PMID 18541493 DOI: 10.1109/Tmi.2008.922699  0.491
2008 Xu D, Cunningham CH, Chen AP, Li Y, Kelley DA, Mukherjee P, Pauly JM, Nelson SJ, Vigneron DB. Phased array 3D MR spectroscopic imaging of the brain at 7 T. Magnetic Resonance Imaging. 26: 1201-6. PMID 18486386 DOI: 10.1016/J.Mri.2008.03.006  0.383
2008 Balchandani P, Pauly J, Spielman D. Interleaved narrow-band PRESS sequence with adiabatic spatial-spectral refocusing pulses for 1H MRSI at 7T. Magnetic Resonance in Medicine. 59: 973-9. PMID 18429014 DOI: 10.1002/Mrm.21539  0.393
2008 Cunningham CH, Chen AP, Lustig M, Hargreaves BA, Lupo J, Xu D, Kurhanewicz J, Hurd RE, Pauly JM, Nelson SJ, Vigneron DB. Pulse sequence for dynamic volumetric imaging of hyperpolarized metabolic products. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 193: 139-46. PMID 18424203 DOI: 10.1016/J.Jmr.2008.03.012  0.577
2008 Lee JH, Dumoulin SO, Saritas EU, Glover GH, Wandell BA, Nishimura DG, Pauly JM. Full-brain coverage and high-resolution imaging capabilities of passband b-SSFP fMRI at 3T. Magnetic Resonance in Medicine. 59: 1099-110. PMID 18421687 DOI: 10.1002/Mrm.21576  0.611
2008 Rakow-Penner R, Gold G, Daniel B, Stevens K, Rosenberg J, Mazin S, Pauly J, Glover GH. Reduction of truncation artifacts in rapid 3D articular cartilage imaging. Journal of Magnetic Resonance Imaging : Jmri. 27: 860-5. PMID 18383247 DOI: 10.1002/Jmri.21312  0.393
2008 Hu S, Lustig M, Chen AP, Crane J, Kerr A, Kelley DA, Hurd R, Kurhanewicz J, Nelson SJ, Pauly JM, Vigneron DB. Compressed sensing for resolution enhancement of hyperpolarized 13C flyback 3D-MRSI. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 192: 258-64. PMID 18367420 DOI: 10.1016/J.Jmr.2008.03.003  0.551
2008 Matter NI, Chronik B, Pauly JM, Macovski A, Conolly SM, Scott GC. Noise performance of a precision pulsed electromagnet power supply for magnetic resonance imaging. Ieee Transactions On Medical Imaging. 27: 75-86. PMID 18270064 DOI: 10.1109/Tmi.2007.903253  0.805
2008 Cukur T, Santos JM, Nishimura DG, Pauly JM. Varying kernel-extent gridding reconstruction for undersampled variable-density spirals. Magnetic Resonance in Medicine. 59: 196-201. PMID 18050316 DOI: 10.1002/Mrm.21329  0.569
2008 Lustig M, Donoho DL, Santos JM, Pauly JM. Compressed sensing MRI: A look at how CS can improve on current imaging techniques Ieee Signal Processing Magazine. 25: 72-82. DOI: 10.1109/Msp.2007.914728  0.606
2007 Larson PE, Conolly SM, Pauly JM, Nishimura DG. Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging. Magnetic Resonance in Medicine. 58: 952-61. PMID 17969119 DOI: 10.1002/Mrm.21341  0.738
2007 Lustig M, Donoho D, Pauly JM. Sparse MRI: The application of compressed sensing for rapid MR imaging. Magnetic Resonance in Medicine. 58: 1182-95. PMID 17969013 DOI: 10.1002/Mrm.21391  0.624
2007 Vidarsson L, Cunningham C, Gold GE, Pauly JM. T2-selective magnetization preparation pulses. Ieee Transactions On Medical Imaging. 26: 981-9. PMID 17649911 DOI: 10.1109/TMI.2007.897390  0.741
2007 Cunningham CH, Chen AP, Albers MJ, Kurhanewicz J, Hurd RE, Yen YF, Pauly JM, Nelson SJ, Vigneron DB. Double spin-echo sequence for rapid spectroscopic imaging of hyperpolarized 13C. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 187: 357-62. PMID 17562376 DOI: 10.1016/J.Jmr.2007.05.014  0.352
2007 Chen AP, Cunningham CH, Ozturk-Isik E, Xu D, Hurd RE, Kelley DA, Pauly JM, Kurhanewicz J, Nelson SJ, Vigneron DB. High-speed 3T MR spectroscopic imaging of prostate with flyback echo-planar encoding. Journal of Magnetic Resonance Imaging : Jmri. 25: 1288-92. PMID 17520729 DOI: 10.1002/Jmri.20916  0.314
2007 Hargreaves BA, Cunningham CH, Pauly JM, Daniel BL. Independent phase modulation for efficient dual-band 3D imaging. Magnetic Resonance in Medicine. 57: 798-802. PMID 17390355 DOI: 10.1002/mrm.21180  0.398
2007 Barral JK, Pelc NJ, Pauly JM, Nishimura DG. Implementation of the derivative back projection - Finite Hilbert inverse algorithm in projection reconstruction MRI Ieee Nuclear Science Symposium Conference Record. 6: 4083-4089. DOI: 10.1109/NSSMIC.2007.4437023  0.487
2006 de la Pena E, Nguyen PK, Nayak KS, Yang PC, Rosenthal DN, Hu BS, Pauly JM, McConnell MV. Real-time color-flow CMR in adults with congenital heart disease. Journal of Cardiovascular Magnetic Resonance : Official Journal of the Society For Cardiovascular Magnetic Resonance. 8: 809-15. PMID 17060103 DOI: 10.1080/10976640600777728  0.477
2006 Larson PE, Gurney PT, Nayak K, Gold GE, Pauly JM, Nishimura DG. Designing long-T2 suppression pulses for ultrashort echo time imaging. Magnetic Resonance in Medicine. 56: 94-103. PMID 16724304 DOI: 10.1002/Mrm.20926  0.714
2006 Cunningham CH, Pauly JM, Nayak KS. Saturated double-angle method for rapid B1+ mapping. Magnetic Resonance in Medicine. 55: 1326-33. PMID 16683260 DOI: 10.1002/Mrm.20896  0.566
2006 Lee J, Santos JM, Conolly SM, Miller KL, Hargreaves BA, Pauly JM. Respiration-induced B0 field fluctuation compensation in balanced SSFP: real-time approach for transition-band SSFP fMRI. Magnetic Resonance in Medicine. 55: 1197-201. PMID 16598728 DOI: 10.1002/Mrm.20879  0.582
2006 Vidarsson L, Gold GE, Hargreaves B, Pauly JM. Linear combination filtering for T2-selective imaging of the knee. Magnetic Resonance in Medicine. 55: 1191-6. PMID 16586458 DOI: 10.1002/Mrm.20878  0.738
2006 Santos JM, Cunningham CH, Lustig M, Hargreaves BA, Hu BS, Nishimura DG, Pauly JM. Single breath-hold whole-heart MRA using variable-density spirals at 3T. Magnetic Resonance in Medicine. 55: 371-9. PMID 16408262 DOI: 10.1002/Mrm.20765  0.745
2005 Terashima M, Hyon M, de la Pena-Almaguer E, Yang PC, Hu BS, Nayak KS, Pauly JM, McConnell MV. High-resolution real-time spiral MRI for guiding vascular interventions in a rabbit model at 1.5 T. Journal of Magnetic Resonance Imaging : Jmri. 22: 687-90. PMID 16217745 DOI: 10.1002/Jmri.20409  0.523
2005 Cunningham CH, Vigneron DB, Chen AP, Xu D, Nelson SJ, Hurd RE, Kelley DA, Pauly JM. Design of flyback echo-planar readout gradients for magnetic resonance spectroscopic imaging. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 54: 1286-9. PMID 16187273 DOI: 10.1002/Mrm.20663  0.397
2005 DiCarlo JC, Hargreaves BA, Nayak KS, Hu BS, Pauly JM, Nishimura DG. Variable-density one-shot Fourier velocity encoding. Magnetic Resonance in Medicine. 54: 645-55. PMID 16088883 DOI: 10.1002/Mrm.20594  0.666
2005 Lee JH, Scott GC, Pauly JM, Nishimura DG. Broadband multicoil imaging using multiple demodulation hardware: a feasibility study. Magnetic Resonance in Medicine. 54: 669-76. PMID 16086362 DOI: 10.1002/Mrm.20595  0.627
2005 Narayan G, Nayak K, Pauly J, Hu B. Single-breathhold, four-dimensional, quantitative assessment of LV and RV function using triggered, real-time, steady-state free precession MRI in heart failure patients. Journal of Magnetic Resonance Imaging : Jmri. 22: 59-66. PMID 15971180 DOI: 10.1002/Jmri.20358  0.522
2005 Beatty PJ, Nishimura DG, Pauly JM. Rapid gridding reconstruction with a minimal oversampling ratio. Ieee Transactions On Medical Imaging. 24: 799-808. PMID 15959939 DOI: 10.1109/Tmi.2005.848376  0.545
2005 Nayak KS, Hargreaves BA, Hu BS, Nishimura DG, Pauly JM, Meyer CH. Spiral balanced steady-state free precession cardiac imaging. Magnetic Resonance in Medicine. 53: 1468-73. PMID 15906302 DOI: 10.1002/Mrm.20489  0.788
2005 Vasanawala SS, Hargreaves BA, Pauly JM, Nishimura DG, Beaulieu CF, Gold GE. Rapid musculoskeletal MRI with phase-sensitive steady-state free precession: comparison with routine knee MRI. Ajr. American Journal of Roentgenology. 184: 1450-5. PMID 15855095 DOI: 10.2214/Ajr.184.5.01841450  0.585
2005 Cunningham CH, Vigneron DB, Marjanska M, Chen AP, Xu D, Hurd RE, Kurhanewicz J, Garwood M, Pauly JM. Sequence design for magnetic resonance spectroscopic imaging of prostate cancer at 3 T. Magnetic Resonance in Medicine. 53: 1033-9. PMID 15844147 DOI: 10.1002/Mrm.20478  0.316
2005 Cunningham CH, Arai T, Yang PC, McConnell MV, Pauly JM, Conolly SM. Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles. Magnetic Resonance in Medicine. 53: 999-1005. PMID 15844142 DOI: 10.1002/Mrm.20477  0.617
2005 Butts K, Pauly JM, Gold GE. Reduction of blurring in view angle tilting MRI. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 53: 418-24. PMID 15678535 DOI: 10.1002/mrm.20375  0.337
2005 Vidarsson L, Conolly SM, Lim KO, Gold GE, Pauly JM. Echo time optimization for linear combination myelin imaging. Magnetic Resonance in Medicine. 53: 398-407. PMID 15678534 DOI: 10.1002/Mrm.20360  0.785
2004 Santos JM, Wright GA, Pauly JM. Flexible real-time magnetic resonance imaging framework. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2: 1048-51. PMID 17271862 DOI: 10.1109/IEMBS.2004.1403343  0.398
2004 Miller KL, Hargreaves BA, Lee J, Ress D, deCharms RC, Pauly JM. Functional brain imaging with BOSS FMRI. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 7: 5234-7. PMID 17271520 DOI: 10.1109/IEMBS.2004.1404463  0.317
2004 Yang PC, Santos JM, Nguyen PK, Scott GC, Engvall J, McConnell MV, Wright GA, Nishimura DG, Pauly JM, Hu BS. Dynamic real-time architecture in magnetic resonance coronary angiography--a prospective clinical trial. Journal of Cardiovascular Magnetic Resonance : Official Journal of the Society For Cardiovascular Magnetic Resonance. 6: 885-94. PMID 15646892 DOI: 10.1081/Jcmr-200036192  0.516
2004 Yang PC, Nguyen P, Shimakawa A, Brittain J, Pauly J, Nishimura D, Hu B, McConnell M. Spiral magnetic resonance coronary angiography--direct comparison of 1.5 Tesla vs. 3 Tesla. Journal of Cardiovascular Magnetic Resonance : Official Journal of the Society For Cardiovascular Magnetic Resonance. 6: 877-84. PMID 15646891 DOI: 10.1081/Jcmr-200036180  0.608
2004 Bangerter NK, Hargreaves BA, Vasanawala SS, Pauly JM, Gold GE, Nishimura DG. Analysis of multiple-acquisition SSFP. Magnetic Resonance in Medicine. 51: 1038-47. PMID 15122688 DOI: 10.1002/Mrm.20052  0.529
2004 Nayak KS, Cunningham CH, Santos JM, Pauly JM. Real-time cardiac MRI at 3 tesla. Magnetic Resonance in Medicine. 51: 655-60. PMID 15065236 DOI: 10.1002/Mrm.20053  0.646
2004 Miller KL, Hargreaves BA, Gold GE, Pauly JM. Steady-state diffusion-weighted imaging of in vivo knee cartilage. Magnetic Resonance in Medicine. 51: 394-8. PMID 14755666 DOI: 10.1002/Mrm.10696  0.331
2003 Asakawa DS, Nayak KS, Blemker SS, Delp SL, Pauly JM, Nishimura DG, Gold GE. Real-time imaging of skeletal muscle velocity. Journal of Magnetic Resonance Imaging : Jmri. 18: 734-9. PMID 14635159 DOI: 10.1002/Jmri.10422  0.684
2003 Miller KL, Hargreaves BA, Lee J, Ress D, deCharms RC, Pauly JM. Functional brain imaging using a blood oxygenation sensitive steady state. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 50: 675-83. PMID 14523951 DOI: 10.1002/Mrm.10602  0.323
2003 Miller KL, Pauly JM. Nonlinear phase correction for navigated diffusion imaging. Magnetic Resonance in Medicine. 50: 343-53. PMID 12876711 DOI: 10.1002/Mrm.10531  0.34
2003 Yang PC, Meyer CH, Terashima M, Kaji S, McConnell MV, Macovski Al, Pauly JM, Nishimura DG, Hu BS. Spiral magnetic resonance coronary angiography with rapid real-time localization. Journal of the American College of Cardiology. 41: 1134-41. PMID 12679213 DOI: 10.1016/S0735-1097(03)00079-2  0.779
2003 Hargreaves BA, Gold GE, Beaulieu CF, Vasanawala SS, Nishimura DG, Pauly JM. Comparison of new sequences for high-resolution cartilage imaging. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 49: 700-9. PMID 12652541 DOI: 10.1002/Mrm.10424  0.65
2003 Nguyen PK, Santos J, Scott G, Engvall J, Wright G, McConnell M, Meyer C, Nishimura D, Pauly J, Hu B, Yang PC. Adaptive real-time architecture in magnetic resonance coronary angiography: Clinical study Journal of the American College of Cardiology. 41: 468-469. DOI: 10.1016/S0735-1097(03)82583-4  0.688
2002 Vasnawala SS, Pauly JM, Nishimura DG, Gold GE. MR imaging of knee cartilage with FEMR. Skeletal Radiology. 31: 574-80. PMID 12324826 DOI: 10.1007/S00256-002-0562-4  0.617
2002 Gold GE, Pauly JM, Leung AN, Block WF, Meyer CH, Sze R, Macovski A, Stark P. Short echo time MR spectroscopic imaging of the lung parenchyma. Journal of Magnetic Resonance Imaging : Jmri. 15: 679-84. PMID 12112518 DOI: 10.1002/Jmri.10113  0.737
2002 Rivas PA, Nayak KS, Scott GC, McConnell MV, Kerr AB, Nishimura DG, Pauly JM, Hu BS. In vivo real-time intravascular MRI. Journal of Cardiovascular Magnetic Resonance : Official Journal of the Society For Cardiovascular Magnetic Resonance. 4: 223-32. PMID 12074137 DOI: 10.1081/Jcmr-120003948  0.737
2001 Wansapura JP, Daniel BL, Pauly J, Butts K. Temperature mapping of frozen tissue using eddy current compensated half excitation RF pulses. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 46: 985-92. PMID 11675651 DOI: 10.1002/Mrm.1285  0.399
2001 Nayak KS, Pauly JM, Yang PC, Hu BS, Meyer CH, Nishimura DG. Real-time interactive coronary MRA Magnetic Resonance in Medicine. 46: 430-435. PMID 11550232 DOI: 10.1002/Mrm.1210  0.754
2001 Kaji S, Yang PC, Kerr AB, Tang WH, Meyer CH, Macovski A, Pauly JM, Nishimura DG, Hu BS. Rapid evaluation of left ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging system. Journal of the American College of Cardiology. 38: 527-33. PMID 11499748 DOI: 10.1016/S0735-1097(01)01399-7  0.773
2001 Hargreaves BA, Vasanawala SS, Pauly JM, Nishimura DG. Characterization and reduction of the transient response in steady-state MR imaging. Magnetic Resonance in Medicine. 46: 149-58. PMID 11443721 DOI: 10.1002/Mrm.1170  0.63
2001 Nayak KS, Rivas PA, Pauly JM, Scott GC, Kerr AB, Hu BS, Nishimura DG. Real-time black-blood MRI using spatial presaturation Journal of Magnetic Resonance Imaging. 13: 807-812. PMID 11329205 DOI: 10.1002/Jmri.1112  0.73
2001 Nayak KS, Pauly JM, Nishimura DG, Hu BS. Rapid ventricular assessment using real-time interactive multislice MRI Magnetic Resonance in Medicine. 45: 371-375. PMID 11241692 DOI: 10.1002/1522-2594(200103)45:3<371::Aid-Mrm1048>3.0.Co;2-Z  0.724
2000 Pauly J. Abstract: real-time interactive MRI for cardiac applications Computer Aided Surgery. 5: 133-133. PMID 10862137 DOI: 10.1002/1097-0150(2000)5:2<133::Aid-Igs9>3.0.Co;2-2  0.331
2000 Sedarat H, Kerr AB, Pauly JM, Nishimura DG. Partial-FOV reconstruction in dynamic spiral imaging. Magnetic Resonance in Medicine. 43: 429-39. PMID 10725886 DOI: 10.1002/(Sici)1522-2594(200003)43:3<429::Aid-Mrm15>3.0.Co;2-M  0.589
2000 Nayak KS, Pauly JM, Kerr AB, Hu BS, Nishimura DG. Real-time color flow MRI Magnetic Resonance in Medicine. 43: 251-258. PMID 10680689 DOI: 10.1002/(Sici)1522-2594(200002)43:2<251::Aid-Mrm12>3.0.Co;2-#  0.7
2000 Vasanawala SS, Pauly JM, Nishimura DG. Linear combination steady-state free precession MRI. Magnetic Resonance in Medicine. 43: 82-90. PMID 10642734 DOI: 10.1002/(Sici)1522-2594(200001)43:1<82::Aid-Mrm10>3.0.Co;2-9  0.656
2000 Pauly J. Real-Time Interactive MRI for Cardiac Applications Computer Aided Surgery. 5: 133-133. DOI: 10.3109/10929080009148881  0.331
1999 Vasanawala SS, Pauly JM, Nishimura DG. Fluctuating equilibrium MRI. Magnetic Resonance in Medicine. 42: 876-83. PMID 10542345 DOI: 10.1002/(Sici)1522-2594(199911)42:5<876::Aid-Mrm6>3.0.Co;2-Z  0.679
1999 Man LC, Pauly JM, Nishimura DG, Macovski A. Nonsubtractive spiral phase contrast velocity imaging Magnetic Resonance in Medicine. 42: 704-713. PMID 10502759 DOI: 10.1002/(Sici)1522-2594(199910)42:4<704::Aid-Mrm12>3.0.Co;2-M  0.716
1999 Hargreaves BA, Gold GE, Lang PK, Conolly SM, Pauly JM, Bergman G, Vandevenne J, Nishimura DG. MR imaging of articular cartilage using driven equilibrium. Magnetic Resonance in Medicine. 42: 695-703. PMID 10502758 DOI: 10.1002/(Sici)1522-2594(199910)42:4<695::Aid-Mrm11>3.0.Co;2-Z  0.761
1999 Kee ST, Rhee JS, Butts K, Daniel B, Pauly J, Kerr A, O'Sullivan GJ, Sze DY, Razavi MK, Semba CP, Herfkens RJ, Dake MD. 1999 Gary J. Becker Young Investigator Award. MR-guided transjugular portosystemic shunt placement in a swine model. Journal of Vascular and Interventional Radiology : Jvir. 10: 529-35. PMID 10357476 DOI: 10.1016/S1051-0443(99)70078-3  0.36
1999 Butts K, Pauly JM, Daniel BL, Kee S, Norbash AM. Management of biopsy needle artifacts: techniques for RF-refocused MRI. Journal of Magnetic Resonance Imaging : Jmri. 9: 586-95. PMID 10232519 DOI: 10.1002/(Sici)1522-2586(199904)9:4<586::Aid-Jmri13>3.0.Co;2-X  0.304
1999 Nielsen HT, Gold GE, Olcott EW, Pauly JM, Nishimura DG. Ultra-short echo-time 2D time-of-flight MR angiography using a half-pulse excitation. Magnetic Resonance in Medicine. 41: 591-9. PMID 10204884 DOI: 10.1002/(Sici)1522-2594(199903)41:3<591::Aid-Mrm23>3.0.Co;2-R  0.617
1998 Adalsteinsson E, Spielman DM, Pauly JM, Terris DJ, Sommer G, Macovski A. Feasibility study of lactate imaging of head and neck tumors. Nmr in Biomedicine. 11: 360-9. PMID 9859942 DOI: 10.1002/(Sici)1099-1492(1998110)11:7<360::Aid-Nbm518>3.0.Co;2-P  0.585
1998 Yang PC, Kerr AB, Liu AC, Liang DH, Hardy C, Meyer CH, Macovski A, Pauly JM, Hu BS. New real-time interactive cardiac magnetic resonance imaging system complements echocardiography. Journal of the American College of Cardiology. 32: 2049-56. PMID 9857892 DOI: 10.1016/S0735-1097(98)00462-8  0.72
1998 Luk Pat GT, Pauly JM, Hu BS, Nishimura DG. One-shot spatially resolved velocity imaging. Magnetic Resonance in Medicine. 40: 603-13. PMID 9771577 DOI: 10.1002/Mrm.1910400413  0.642
1998 Gold GE, Thedens DR, Pauly JM, Fechner KP, Bergman G, Beaulieu CF, Macovski A. Technical innovation. MR imaging of articular cartilage of the knee: New methods using ultrashort tes American Journal of Roentgenology. 170: 1223-1226. PMID 9574589 DOI: 10.2214/Ajr.170.5.9574589  0.599
1998 Yang P, Kerr A, Liu A, Liang D, Hardy C, Meyer C, Macovski A, Pauly J, Hu B. New real-time interactive cardiac magnetic resonance imaging system Journal of the American College of Cardiology. 31: 3-4. DOI: 10.1016/S0735-1097(98)80682-7  0.742
1997 Butts K, Pauly J, de Crespigny A, Moseley M. Isotropic diffusion-weighted and spiral-navigated interleaved EPI for routine imaging of acute stroke. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 38: 741-9. PMID 9358448 DOI: 10.1002/Mrm.1910380510  0.401
1997 Kerr AB, Pauly JM, Hu BS, Li KC, Hardy CJ, Meyer CH, Macovski A, Nishimura DG. Real-time interactive MRI on a conventional scanner. Magnetic Resonance in Medicine. 38: 355-67. PMID 9339436 DOI: 10.1002/Mrm.1910380303  0.803
1997 Liao JR, Pauly JM, Pelc NJ. MRI using piecewise-linear spiral trajectory Magnetic Resonance in Medicine. 38: 246-252. PMID 9256104 DOI: 10.1002/Mrm.1910380213  0.35
1997 Block W, Pauly J, Kerr A, Nishimura D. Consistent fat suppression with compensated spectral-spatial pulses. Magnetic Resonance in Medicine. 38: 198-206. PMID 9256098 DOI: 10.1002/Mrm.1910380207  0.633
1997 Star-Lack J, Vigneron DB, Pauly J, Kurhanewicz J, Nelson SJ. Improved solvent suppression and increased spatial excitation bandwidths for three-dimensional PRESS CSI using phase-compensating spectral/spatial spin-echo pulses. Journal of Magnetic Resonance Imaging : Jmri. 7: 745-57. PMID 9243397 DOI: 10.1002/Jmri.1880070422  0.396
1997 Man LC, Pauly JM, Macovski A. Improved automatic off-resonance correction without a field map in spiral imaging Magnetic Resonance in Medicine. 37: 906-913. PMID 9178243 DOI: 10.1002/Mrm.1910370616  0.599
1997 Mani S, Pauly J, Conolly S, Meyer C, Nishimura D. Background suppression with multiple inversion recovery nulling: applications to projective angiography. Magnetic Resonance in Medicine. 37: 898-905. PMID 9178242 DOI: 10.1002/Mrm.1910370615  0.783
1997 Man LC, Pauly JM, Macovski A. Multifrequency interpolation for fast off-resonance correction Magnetic Resonance in Medicine. 37: 785-792. PMID 9126954 DOI: 10.1002/Mrm.1910370523  0.643
1997 Brossmann J, Frank LR, Pauly JM, Boutin RD, Pedowitz RA, Haghighi P, Resnick D. Short echo time projection reconstruction MR imaging of cartilage: comparison with fat-suppressed spoiled GRASS and magnetization transfer contrast MR imaging. Radiology. 203: 501-7. PMID 9114112 DOI: 10.1148/radiology.203.2.9114112  0.415
1997 Block W, Pauly J, Nishimura D. RARE spiral T2-weighted imaging. Magnetic Resonance in Medicine. 37: 582-90. PMID 9094081 DOI: 10.1002/Mrm.1910370418  0.662
1997 Luk Pat GT, Meyer CH, Pauly JM, Nishimura DG. Reducing flow artifacts in echo-planar imaging Magnetic Resonance in Medicine. 37: 436-447. PMID 9055235 DOI: 10.1002/Mrm.1910370323  0.674
1997 Alley MT, Pauly JM, Sommer FG, Pelc NJ. Angiographic imaging with 2D RF pulses Magnetic Resonance in Medicine. 37: 260-267. PMID 9001151 DOI: 10.1002/Mrm.1910370220  0.44
1996 Glover GH, Lemieux SK, Drangova M, Pauly JM. Decomposition of inflow and blood oxygen level-dependent (BOLD) effects with dual-echo spiral gradient-recalled echo (GRE) fMRI Magnetic Resonance in Medicine. 35: 299-308. PMID 8699940 DOI: 10.1002/Mrm.1910350306  0.328
1996 Kerr AB, Pauly J. 5499629 Slice profile stabilization for segmented K-space magnetic resonance imaging Magnetic Resonance Imaging. 14: VIII. DOI: 10.1016/S0730-725X(97)87350-X  0.321
1995 Gold GE, Pauly JM, Macovski A, Herfkens RJ. MR spectroscopic imaging of collagen: Tendons and knee menisci Magnetic Resonance in Medicine. 34: 647-654. PMID 8544684 DOI: 10.1002/Mrm.1910340502  0.63
1995 Spielman DM, Pauly JM. Spiral imaging on a small-bore system at 4.7T. Magnetic Resonance in Medicine. 34: 580-5. PMID 8524026 DOI: 10.1002/Mrm.1910340414  0.429
1995 Spielman DM, Pauly JM, Meyer CH. Magnetic resonance fluoroscopy using spirals with variable sampling densities. Magnetic Resonance in Medicine. 34: 388-94. PMID 7500878 DOI: 10.1002/Mrm.1910340316  0.656
1995 Noll DC, Pauly J, Macovski A. 5311132 Method of enhancing the focus of magnetic resonance images Magnetic Resonance Imaging. 13: XXVII-XXVIII. DOI: 10.1016/0730-725X(95)90109-I  0.745
1995 Irarrazabal P, Hu BS, Pauly J. Method of determining real-time spatially localized velocity distribution using magnetic resonance measurements Magnetic Resonance Imaging. 13. DOI: 10.1016/0730-725X(95)90099-Q  0.412
1995 Spielman D, Pauly JM. 5283526 Method for performing single and multiple slice magnetic resonance spectroscopic imaging Magnetic Resonance Imaging. 13: X. DOI: 10.1016/0730-725X(95)90039-8  0.4
1994 Lim KO, Pauly J, Webb P, Hurd R, Macovski A. Short TE phosphorus spectroscopy using a spin-echo pulse Magnetic Resonance in Medicine. 32: 98-103. PMID 8084242 DOI: 10.1002/Mrm.1910320113  0.605
1993 Gold GE, Pauly JM, Glover GH, Moretto JC, Macovski A, Herfkens RJ. Characterization of atherosclerosis with a 1.5-T imaging system Journal of Magnetic Resonance Imaging : Jmri. 3: 399-407. PMID 8448403 DOI: 10.1002/Jmri.1880030216  0.624
1993 Pauly JM, Hu BS, Wang SJ, Nishimura DG, Macovski A. A three-dimensional spin-echo or inversion pulse Magnetic Resonance in Medicine. 29: 2-6. PMID 8419739 DOI: 10.1002/Mrm.1910290103  0.696
1993 Hu BS, Pauly JM, Nishimura DG. Localized real-time velocity spectra determination. Magnetic Resonance in Medicine. 30: 393-8. PMID 8412614 DOI: 10.1002/Mrm.1910300319  0.584
1993 Adalsteinsson E, Spielman DM, Wright GA, Pauly JM, Meyer CH, Macovski A. Incorporating lactate/lipid discrimination into a spectroscopic imaging sequence. Magnetic Resonance in Medicine. 30: 124-30. PMID 8371666 DOI: 10.1002/Mrm.1910300119  0.729
1993 Irarrazabal P, Hu BS, Pauly JM, Nishimura DG. Spatially resolved and localized real-time velocity distribution. Magnetic Resonance in Medicine. 30: 207-12. PMID 8366802 DOI: 10.1002/Mrm.1910300209  0.55
1993 Pauly J, Spielman D, Macovski A. Echo-planar spin-echo and inversion pulses Magnetic Resonance in Medicine. 29: 776-782. PMID 8350720 DOI: 10.1002/Mrm.1910290609  0.597
1993 Bergin CJ, Glover GM, Pauly J. Magnetic resonance imaging of lung parenchyma Journal of Thoracic Imaging. 8: 12-17. DOI: 10.1097/00005382-199320000-00003  0.45
1993 Conolly SM, Pauly J. 5189371 Method and means for magnetic resonance imaging and spectroscopy using two-dimensional selective adiabatic PI pulses Magnetic Resonance Imaging. 11: XLIV. DOI: 10.1016/0730-725X(93)90326-9  0.671
1993 Pauly JM. 5105152 Magnetic resonance imaging and spectroscopy using a linear class of large tip-angle selective excitation pulses Magnetic Resonance Imaging. 11: V. DOI: 10.1016/0730-725X(93)90096-V  0.36
1992 Nishimura DG, Jackson JI, Pauly JM. On the nature and reduction of the displacement artifact in flow images. Magnetic Resonance in Medicine. 22: 481-92. PMID 1812381 DOI: 10.1002/Mrm.1910220255  0.597
1992 Spielman DM, Pauly JM, Macovski A, Glover GH, Enzmann DR. Lipid-suppressed single- and multisection proton spectroscopic imaging of the human brain. Journal of Magnetic Resonance Imaging : Jmri. 2: 253-62. PMID 1627859 DOI: 10.1002/Jmri.1880020302  0.634
1992 Glover GH, Pauly JM, Bradshaw KM. Boron-11 imaging with a three-dimensional reconstruction method. Journal of Magnetic Resonance Imaging : Jmri. 2: 47-52. PMID 1623280 DOI: 10.1002/Jmri.1880020109  0.32
1992 Noll DC, Pauly JM, Meyer CH, Nishimura DG, Macovski A. Deblurring for non-2D Fourier transform magnetic resonance imaging. Magnetic Resonance in Medicine. 25: 319-33. PMID 1614315 DOI: 10.1002/mrm.1910250210  0.832
1992 Bergin CJ, Noll DC, Pauly JM, Glover GH, Macovski A. MR imaging of lung parenchyma: A solution to susceptibility Radiology. 183: 673-676. PMID 1584917 DOI: 10.1148/Radiology.183.3.1584917  0.745
1992 Conolly S, Pauly J, Nishimura D, Macovski A. Two-dimensional selective adiabatic pulses. Magnetic Resonance in Medicine. 24: 302-13. PMID 1569869 DOI: 10.1002/mrm.1910240211  0.791
1992 Chan F, Pauly J, Macovski A. Effects of RF amplifier distortion on selective excitation and their correction by prewarping Magnetic Resonance in Medicine. 23: 224-238. PMID 1549038 DOI: 10.1002/Mrm.1910230204  0.62
1992 Pauly JM. 4985677 Magnetic resonance imaging and spectroscopy using an excitation pulse for multiple-dimensional selectivity Magnetic Resonance Imaging. 10: I-II. DOI: 10.1016/0730-725X(92)90526-6  0.384
1991 Noll DC, Meyer CH, Pauly JM, Nishimura DG, Macovski A. A homogeneity correction method for magnetic resonance imaging with time-varying gradients. Ieee Transactions On Medical Imaging. 10: 629-37. PMID 18222870 DOI: 10.1109/42.108599  0.829
1991 Spielman D, Pauly J, Macovski A, Enzmann D. Spectroscopic imaging with multidimensional pulses for excitation: SIMPLE Magnetic Resonance in Medicine. 19: 67-84. PMID 2046539 DOI: 10.1002/Mrm.1910190107  0.661
1991 Bergin CJ, Pauly JM, Macovski A. Lung parenchyma: Projection reconstruction MR imaging Radiology. 179: 777-781. PMID 2027991 DOI: 10.1148/radiology.179.3.2027991  0.598
1991 Pauly J, Nishimura D, Macovski A, Roux PL. Parameter Relations for the Shinnar-Le Roux Selective Excitation Pulse Design Algorithm Ieee Transactions On Medical Imaging. 10: 53-65. DOI: 10.1109/42.75611  0.704
1990 Meyer CH, Pauly JM, Macovski A, Nishimura DG. Simultaneous spatial and spectral selective excitation. Magnetic Resonance in Medicine. 15: 287-304. PMID 2392053 DOI: 10.1002/mrm.1910150211  0.799
1989 Pauly J, Nishimura D, Macovski A. A linear class of large-tip-angle selective excitation pulses Journal of Magnetic Resonance (1969). 82: 571-587. DOI: 10.1016/0022-2364(89)90219-9  0.685
1988 Nishimura DG, Macovski A, Pauly JM. Considerations of magnetic resonance angiography by selective inversion recovery. Magnetic Resonance in Medicine. 7: 472-84. PMID 3173062 DOI: 10.1002/Mrm.1910070410  0.737
1987 Nishimura DG, Macovski A, Pauly JM, Conolly SM. MR angiography by selective inversion recovery. Magnetic Resonance in Medicine. 4: 193-202. PMID 3561250 DOI: 10.1002/Mrm.1910040214  0.763
Show low-probability matches.