Jeffrey A. Fessler - Publications

Affiliations: 
University of Michigan, Ann Arbor, Ann Arbor, MI 
Area:
Biomedical Engineering, Electronics and Electrical Engineering, Computer Science

305 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2024 Xiang H, Fessler JA, Noll DC. Model-based reconstruction for looping-star MRI. Magnetic Resonance in Medicine. PMID 38282253 DOI: 10.1002/mrm.29927  0.602
2023 Gao M, Fessler JA, Chan HP. Model-based deep CNN-regularized reconstruction for digital breast tomosynthesis with a task-based CNN image assessment approach. Physics in Medicine and Biology. 68. PMID 37988758 DOI: 10.1088/1361-6560/ad0eb4  0.313
2023 Kim H, Li Z, Son J, Fessler JA, Dewaraja YK, Chun SY. Physics-Guided Deep Scatter Estimation by Weak Supervision for Quantitative SPECT. Ieee Transactions On Medical Imaging. PMID 37104110 DOI: 10.1109/TMI.2023.3270868  0.547
2023 Wang G, Fessler JA. Efficient Approximation of Jacobian Matrices Involving a Non-Uniform Fast Fourier Transform (NUFFT). Ieee Transactions On Computational Imaging. 9: 43-54. PMID 37090025 DOI: 10.1109/tci.2023.3240081  0.374
2023 Wang G, Nielsen JF, Fessler JA, Noll DC. Stochastic optimization of three-dimensional non-Cartesian sampling trajectory. Magnetic Resonance in Medicine. PMID 37066854 DOI: 10.1002/mrm.29645  0.5
2022 Huang Z, Fessler JA, Norris TB. Focal stack based image forgery localization. Applied Optics. 61: 4030-4039. PMID 36256076 DOI: 10.1364/AO.450654  0.307
2022 Wang G, Luo T, Nielsen JF, Noll DC, Fessler JA. B-spline Parameterized Joint Optimization of Reconstruction and K-space Trajectories (BJORK) for Accelerated 2D MRI. Ieee Transactions On Medical Imaging. PMID 35320096 DOI: 10.1109/TMI.2022.3161875  0.611
2022 Martinez C, Fessler JA, Desco M, Abella M. Simple beam hardening correction method (2DCalBH) based on 2D linearization. Physics in Medicine and Biology. 67. PMID 35313288 DOI: 10.1088/1361-6560/ac5f71  0.318
2021 Zeng R, Lin CY, Li Q, Lu J, Skopec M, Fessler JA, Myers KJ. Performance of a deep learning-based CT image denoising method: Generalizability over dose, reconstruction kernel and slice thickness. Medical Physics. PMID 34954845 DOI: 10.1002/mp.15430  0.583
2021 Luo T, Noll DC, Fessler JA, Nielsen JF. Joint Design of RF and gradient waveforms via auto-differentiation for 3D tailored excitation in MRI. Ieee Transactions On Medical Imaging. PMID 34029188 DOI: 10.1109/TMI.2021.3083104  0.549
2020 Lin CY, Fessler JA. Efficient Regularized Field Map Estimation in 3D MRI. Ieee Transactions On Computational Imaging. 6: 1451-1458. PMID 33693053 DOI: 10.1109/TCI.2020.3031082  0.344
2020 Guo S, Fessler JA, Noll DC. High-Resolution Oscillating Steady-State fMRI using Patch-Tensor Low-Rank Reconstruction. Ieee Transactions On Medical Imaging. PMID 32809938 DOI: 10.1109/Tmi.2020.3017450  0.616
2020 Chun IY, Huang Z, Lim H, Fessler J. Momentum-Net: Fast and convergent iterative neural network for inverse problems. Ieee Transactions On Pattern Analysis and Machine Intelligence. PMID 32750839 DOI: 10.1109/Tpami.2020.3012955  0.475
2020 Lim H, Chun IY, Dewaraja YK, Fessler JA. Improved low-count quantitative PET reconstruction with an iterative neural network. Ieee Transactions On Medical Imaging. PMID 32746100 DOI: 10.1109/Tmi.2020.2998480  0.44
2020 Xiang H, Lim H, Fessler JA, Dewaraja YK. A deep neural network for fast and accurate scatter estimation in quantitative SPECT/CT under challenging scatter conditions. European Journal of Nuclear Medicine and Molecular Imaging. PMID 32415551 DOI: 10.1007/S00259-020-04840-9  0.375
2020 Fessler JA. Optimization Methods for Magnetic Resonance Image Reconstruction: Key Models and Optimization Algorithms. Ieee Signal Processing Magazine. 37: 33-40. PMID 32317844 DOI: 10.1109/Msp.2019.2943645  0.436
2020 Moore BE, Ravishankar S, Nadakuditi RR, Fessler JA. Online Adaptive Image Reconstruction (OnAIR) Using Dictionary Models. Ieee Transactions On Computational Imaging. 6: 153-166. PMID 32095490 DOI: 10.1109/Tci.2019.2931092  0.476
2020 Ravishankar S, Ye JC, Fessler JA. Image Reconstruction: From Sparsity to Data-adaptive Methods and Machine Learning. Proceedings of the Ieee. Institute of Electrical and Electronics Engineers. 108: 86-109. PMID 32095024 DOI: 10.1109/Jproc.2019.2936204  0.49
2020 Lien M, Liu C, Chun IY, Ravishankar S, Nien H, Zhou M, Fessler JA, Zhong Z, Norris TB. Ranging and light field imaging with transparent photodetectors Nature Photonics. 14: 143-148. DOI: 10.1038/S41566-019-0567-3  0.309
2019 Lahiri A, Fessler JA, Hernandez-Garcia L. Optimizing MRF-ASL scan design for precise quantification of brain hemodynamics using neural network regression. Magnetic Resonance in Medicine. PMID 31751497 DOI: 10.1002/Mrm.28051  0.368
2019 Lin CY, Fessler JA. Efficient Dynamic Parallel MRI Reconstruction for the Low-Rank Plus Sparse Model. Ieee Transactions On Computational Imaging. 5: 17-26. PMID 31750391 DOI: 10.1109/Tci.2018.2882089  0.42
2019 Chun SY, Nguyen MP, Phan TQ, Kim H, Fessler JA, Dewaraja YK. Algorithms and Analyses for Joint Spectral Image Reconstruction in Y-90 Bremsstrahlung SPECT. Ieee Transactions On Medical Imaging. PMID 31647425 DOI: 10.1109/Tmi.2019.2949068  0.641
2019 Li Z, Ravishankar S, Long Y, Fessler JA. DECT-MULTRA: Dual-Energy CT Image Decomposition With Learned Mixed Material Models and Efficient Clustering. Ieee Transactions On Medical Imaging. PMID 31603815 DOI: 10.1109/Tmi.2019.2946177  0.597
2019 Zheng J, Fessler JA, Chan HP. Effect of Source Blur on Digital Breast Tomosynthesis Reconstruction. Medical Physics. PMID 31494953 DOI: 10.1002/Mp.13801  0.34
2019 Chun IY, Fessler JA. Convolutional Analysis Operator Learning: Acceleration and Convergence (Supplementary Material). Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. PMID 31484120 DOI: 10.1109/Tip.2019.2937734  0.302
2019 Ye S, Ravishankar S, Long Y, Fessler JA. SPULTRA: Low-Dose CT Image Reconstruction with Joint Statistical and Learned Image Models. Ieee Transactions On Medical Imaging. PMID 31425021 DOI: 10.1109/Tmi.2019.2934933  0.632
2019 Abella M, Martinez C, Desco M, Vaquero JJ, Fessler JA. Simplified Statistical Image Reconstruction for X-ray CT with Beam-Hardening Artifact Compensation. Ieee Transactions On Medical Imaging. PMID 31180844 DOI: 10.1109/Tmi.2019.2921929  0.443
2019 Luo T, Noll DC, Fessler JA, Nielsen JF. A GRAPPA algorithm for arbitrary 2D/3D non-Cartesian sampling trajectories with rapid calibration. Magnetic Resonance in Medicine. PMID 31050011 DOI: 10.1002/Mrm.27801  0.628
2019 Weller DS, Noll DC, Fessler JA. Real-Time Filtering with Sparse Variations for Head Motion in Magnetic Resonance Imaging. Signal Processing. 157: 170-179. PMID 30618478 DOI: 10.1016/J.Sigpro.2018.12.001  0.763
2018 Hong D, Balzano L, Fessler JA. Asymptotic performance of PCA for high-dimensional heteroscedastic data. Journal of Multivariate Analysis. 167: 435-452. PMID 30778267 DOI: 10.1016/J.Jmva.2018.06.002  0.306
2018 Kim K, Kim D, Yang J, El Fakhri G, Seo Y, Fessler JA, Li Q. Time of flight PET reconstruction using non-uniform update for regional recovery uniformity. Medical Physics. PMID 30508255 DOI: 10.1002/Mp.13321  0.417
2018 Nataraj G, Nielsen JF, Scott C, Fessler JA. Dictionary-Free MRI PERK: Parameter Estimation via Regression with Kernels. Ieee Transactions On Medical Imaging. PMID 29994085 DOI: 10.1109/Tmi.2018.2817547  0.388
2018 Zheng X, Ravishankar S, Long Y, Fessler JA. PWLS-ULTRA: An Efficient Clustering and Learning-Based Approach for Low-Dose 3D CT Image Reconstruction. Ieee Transactions On Medical Imaging. 37: 1498-1510. PMID 29870377 DOI: 10.1109/Tmi.2018.2832007  0.639
2018 Wang G, Ye JC, Mueller K, Fessler JA. Image Reconstruction is a New Frontier of Machine Learning. Ieee Transactions On Medical Imaging. 37: 1289-1296. PMID 29870359 DOI: 10.1109/Tmi.2018.2833635  0.388
2018 Kim D, Fessler JA. ANOTHER LOOK AT THE FAST ITERATIVE SHRINKAGE/THRESHOLDING ALGORITHM (FISTA). Siam Journal On Optimization : a Publication of the Society For Industrial and Applied Mathematics. 28: 223-250. PMID 29805242 DOI: 10.1137/16M108940X  0.369
2018 Lim H, Fessler JA, Wilderman SJ, Brooks AF, Dewaraja YK. Y-90 SPECT ML image reconstruction with a new model for tissue-dependent bremsstrahlung production using CT information: a proof-of-concept study. Physics in Medicine and Biology. PMID 29714716 DOI: 10.1088/1361-6560/Aac1Ad  0.435
2018 Olafsson VT, Noll DC, Fessler JA. Fast Spatial Resolution Analysis of Quadratic Penalized Least-Squares Image Reconstruction With Separate Real and Imaginary Roughness Penalty: Application to fMRI. Ieee Transactions On Medical Imaging. 37: 604-614. PMID 29408788 DOI: 10.1109/Tmi.2017.2768825  0.682
2018 Lim H, Dewaraja YK, Fessler JA. A PET reconstruction formulation that enforces non-negativity in projection space for bias reduction in Y-90 imaging. Physics in Medicine and Biology. PMID 29327692 DOI: 10.1088/1361-6560/Aaa71B  0.476
2018 Yoon S, Makiharju SA, Fessler JA, Ceccio SL. Image Reconstruction for Limited-Angle Electron Beam X-Ray Computed Tomography With Energy-Integrating Detectors for Multiphase Flows Ieee Transactions On Computational Imaging. 4: 112-124. DOI: 10.1109/Tci.2017.2775603  0.464
2018 Kim D, Fessler JA. Adaptive Restart of the Optimized Gradient Method for Convex Optimization Journal of Optimization Theory and Applications. 178: 240-263. DOI: 10.1007/S10957-018-1287-4  0.353
2017 Ravishankar S, Nadakuditi RR, Fessler JA. Efficient Sum of Outer Products Dictionary Learning (SOUP-DIL) and Its Application to Inverse Problems. Ieee Transactions On Computational Imaging. 3: 694-709. PMID 29376111 DOI: 10.1109/Tci.2017.2697206  0.423
2017 Chun IY, Fessler JA. Convolutional Dictionary Learning: Acceleration and Convergence. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. PMID 28991744 DOI: 10.1109/Tip.2017.2761545  0.377
2017 Dewaraja YK, Chun SY, Srinivasa RN, Kaza RK, Cuneo KC, Majdalany BS, Novelli PM, Ljungberg M, Fessler JA. Improved quantitative (90) Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling. Medical Physics. PMID 28940483 DOI: 10.1002/Mp.12597  0.633
2017 Zheng J, Fessler JA, Chan HP. Detector Blur and Correlated Noise Modeling for Digital Breast Tomosynthesis Reconstruction. Ieee Transactions On Medical Imaging. PMID 28767366 DOI: 10.1109/Tmi.2017.2732824  0.416
2017 Williams SN, Nielsen JF, Fessler JA, Noll DC. Design of spectral-spatial phase prewinding pulses and their use in small-tip fast recovery steady-state imaging. Magnetic Resonance in Medicine. PMID 28671320 DOI: 10.1002/Mrm.26794  0.555
2017 Le M, Fessler JA. Efficient, Convergent SENSE MRI Reconstruction for Nonperiodic Boundary Conditions via Tridiagonal Solvers. Ieee Transactions On Computational Imaging. 3: 11-21. PMID 28503635 DOI: 10.1109/Tci.2016.2626999  0.404
2017 Kim D, Fessler JA. On the Convergence Analysis of the Optimized Gradient Method. Journal of Optimization Theory and Applications. 172: 187-205. PMID 28461707 DOI: 10.1007/S10957-016-1018-7  0.316
2017 Liu L, Jolly S, Cao Y, Vineberg K, Fessler JA, Balter JM. Female pelvic synthetic CT generation based on joint intensity and shape analysis. Physics in Medicine and Biology. 62: 2935-2949. PMID 28306550 DOI: 10.1088/1361-6560/62/8/2935  0.597
2017 Ravishankar S, Moore B, Nadakuditi R, Fessler J. Low-rank and Adaptive Sparse Signal (LASSI) Models for Highly Accelerated Dynamic Imaging. Ieee Transactions On Medical Imaging. PMID 28092528 DOI: 10.1109/Tmi.2017.2650960  0.46
2017 Zheng J, Fessler JA, Chan HP. Segmented Separable Footprint Projector for Digital Breast Tomosynthesis and Its application for Subpixel Reconstruction. Medical Physics. PMID 28058719 DOI: 10.1002/Mp.12092  0.401
2017 Nataraj G, Nielsen JF, Fessler JA. Optimizing MR Scan Design for Model-Based ${T}_{1}$ , ${T}_{2}$ Estimation From Steady-State Sequences. Ieee Transactions On Medical Imaging. 36: 467-477. PMID 27893386 DOI: 10.1109/Tmi.2016.2614967  0.314
2017 Zheng J, Fessler JA, Chan HP. Effects of detector blur and correlated noise on digital breast tomosynthesis reconstruction Proceedings of Spie. 10132: 1013226. DOI: 10.1117/12.2255689  0.41
2017 Xie X, McGaffin MG, Long Y, Fessler JA, Wen M, Lin J. Accelerating separable footprint (SF) forward and back projection on GPU Proceedings of Spie. 10132. DOI: 10.1117/12.2252010  0.626
2016 Cauble MA, Muckley MJ, Fang M, Fessler JA, Welch K, Rothman ED, Orr BG, Duong LT, Holl MMB. Estrogen depletion and drug treatment alter the microstructure of type I collagen in bone. Bone Reports. 5: 243-251. PMID 28580393 DOI: 10.1016/J.Bonr.2016.08.003  0.308
2016 Liu L, Jolly S, Cao Y, Vineberg K, Fessler J, Balter J. SU-D-207A-01: Female Pelvic Synthetic CT Generation Based On Joint Shape and Intensity Analysis. Medical Physics. 43: 3343. PMID 28046444 DOI: 10.1118/1.4955648  0.58
2016 Kim D, Fessler JA. Optimized first-order methods for smooth convex minimization. Mathematical Programming. 159: 81-107. PMID 27765996 DOI: 10.1007/S10107-015-0949-3  0.347
2016 Schmitt S, Goodsitt M, Fessler J. Fast Variance Prediction for Iteratively Reconstructed CT Images with Locally Quadratic Regularization. Ieee Transactions On Medical Imaging. PMID 27448342 DOI: 10.1109/Tmi.2016.2593259  0.489
2016 Nien H, Fessler JA. Relaxed Linearized Algorithms for Faster X-Ray CT Image Reconstruction. Ieee Transactions On Medical Imaging. 35: 1090-8. PMID 26685227 DOI: 10.1109/Tmi.2015.2508780  0.453
2016 Zheng J, Fessler JA, Chan HP. Digital breast tomosynthesis reconstruction using spatially weighted non-convex regularization Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9783. DOI: 10.1117/12.2216414  0.396
2016 Chu J, Streicher M, Fessler JA, He Z. Unbiased Filtered Back-Projection in $4\pi$ Compton Imaging With 3D Position Sensitive Detectors Ieee Transactions On Nuclear Science. 63: 2750-2756. DOI: 10.1109/Tns.2016.2610980  0.487
2015 McGaffin MG, Fessler JA. Alternating dual updates algorithm for X-ray CT reconstruction on the GPU. Ieee Transactions On Computational Imaging. 1: 186-199. PMID 26878031 DOI: 10.1109/Tci.2015.2479555  0.446
2015 Weller DS, Pnueli A, Divon G, Radzyner O, Eldar YC, Fessler JA. Undersampled Phase Retrieval with Outliers. Ieee Transactions On Computational Imaging. 1: 247-258. PMID 26770999 DOI: 10.1109/Tci.2015.2498402  0.729
2015 Liu L, Cao Y, Fessler JA, Jolly S, Balter JM. A female pelvic bone shape model for air/bone separation in support of synthetic CT generation for radiation therapy. Physics in Medicine and Biology. 61: 169-182. PMID 26624989 DOI: 10.1088/0031-9155/61/1/169  0.586
2015 Sun H, Fessler JA, Noll DC, Nielsen JF. Rapid inner-volume imaging in the steady-state with 3D selective excitation and small-tip fast recovery imaging. Magnetic Resonance in Medicine. PMID 26507586 DOI: 10.1002/Mrm.26026  0.609
2015 Gregor J, Fessler JA. Comparison of SIRT and SQS for Regularized Weighted Least Squares Image Reconstruction. Ieee Transactions On Computational Imaging. 1: 44-55. PMID 26478906 DOI: 10.1109/Tci.2015.2442511  0.461
2015 Sun H, Fessler J, Noll D, Nielsen JF. Joint design of excitation k-space trajectory and RF pulse for small-tip 3D tailored excitation in MRI. Ieee Transactions On Medical Imaging. PMID 26390450 DOI: 10.1109/Tmi.2015.2478880  0.58
2015 Liu L, Cao Y, Fessler J, Balter J. SU-F-303-14: Investigation of a Pelvic Bone Shape Model in Support of Bone Classification for Synthetic CT Generation. Medical Physics. 42: 3541. PMID 26128541 DOI: 10.1118/1.4925241  0.571
2015 Sun H, Fessler JA, Noll DC, Nielsen JF. Balanced SSFP-like steady-state imaging using small-tip fast recovery with a spectral prewinding pulse. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. PMID 25820494 DOI: 10.1002/Mrm.25682  0.582
2015 McGaffin MG, Fessler JA. Edge-preserving image denoising via group coordinate descent on the GPU. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. 24: 1273-81. PMID 25675454 DOI: 10.1109/Tip.2015.2400813  0.441
2015 Cho JH, Fessler JA. Regularization designs for uniform spatial resolution and noise properties in statistical image reconstruction for 3-D X-ray CT. Ieee Transactions On Medical Imaging. 34: 678-89. PMID 25361500 DOI: 10.1109/Tmi.2014.2365179  0.467
2015 Muckley MJ, Noll DC, Fessler JA. Fast parallel MR image reconstruction via B1-based, adaptive restart, iterative soft thresholding algorithms (BARISTA). Ieee Transactions On Medical Imaging. 34: 578-88. PMID 25330484 DOI: 10.1109/Tmi.2014.2363034  0.651
2015 Zhao F, Nielsen JF, Swanson SD, Fessler JA, Noll DC. Simultaneous fat saturation and magnetization transfer contrast imaging with steady-state incoherent sequences. Magnetic Resonance in Medicine. 74: 739-46. PMID 25252173 DOI: 10.1002/Mrm.25475  0.536
2015 Nien H, Fessler JA. Fast X-ray CT image reconstruction using a linearized augmented Lagrangian method with ordered subsets. Ieee Transactions On Medical Imaging. 34: 388-99. PMID 25248178 DOI: 10.1109/Tmi.2014.2358499  0.46
2015 Kim D, Ramani S, Fessler JA. Combining ordered subsets and momentum for accelerated X-ray CT image reconstruction. Ieee Transactions On Medical Imaging. 34: 167-78. PMID 25163058 DOI: 10.1109/Tmi.2014.2350962  0.472
2015 Sun H, Fessler JA, Noll DC, Nielsen JF. Steady-state functional MRI using spoiled small-tip fast recovery imaging. Magnetic Resonance in Medicine. 73: 536-43. PMID 24619593 DOI: 10.1002/Mrm.25146  0.624
2015 Kim D, Fessler JA. An optimized first-order method for image restoration Proceedings - International Conference On Image Processing, Icip. 2015: 3675-3679. DOI: 10.1109/ICIP.2015.7351490  0.304
2015 Nien H, Fessler JA, Sick V. Model-based image reconstruction of chemiluminescence using a plenoptic 2.0 camera Proceedings - International Conference On Image Processing, Icip. 2015: 359-363. DOI: 10.1109/ICIP.2015.7350820  0.369
2014 Chun SY, Dewaraja YK, Fessler JA. Alternating direction method of multiplier for tomography with nonlocal regularizers. Ieee Transactions On Medical Imaging. 33: 1960-8. PMID 25291351 DOI: 10.1109/Tmi.2014.2328660  0.678
2014 Zhao F, Fessler JA, Wright SM, Noll DC. Regularized estimation of magnitude and phase of multi-coil b1 field via Bloch-Siegert B1 mapping and coil combination optimizations. Ieee Transactions On Medical Imaging. 33: 2020-30. PMID 24951683 DOI: 10.1109/Tmi.2014.2329751  0.595
2014 Long Y, Fessler JA. Multi-material decomposition using statistical image reconstruction for spectral CT. Ieee Transactions On Medical Imaging. 33: 1614-26. PMID 24801550 DOI: 10.1109/Tmi.2014.2320284  0.612
2014 Sun H, Fessler JA, Noll DC, Nielsen JF. Strategies for improved 3D small-tip fast recovery imaging. Magnetic Resonance in Medicine. 72: 389-98. PMID 24127132 DOI: 10.1002/Mrm.24947  0.631
2014 Weller DS, Ramani S, Fessler JA. Augmented Lagrangian with variable splitting for faster non-Cartesian L1-SPIRiT MR image reconstruction. Ieee Transactions On Medical Imaging. 33: 351-61. PMID 24122551 DOI: 10.1109/Tmi.2013.2285046  0.733
2014 Weller DS, Ramani S, Nielsen JF, Fessler JA. Monte Carlo SURE-based parameter selection for parallel magnetic resonance imaging reconstruction. Magnetic Resonance in Medicine. 71: 1760-70. PMID 23821331 DOI: 10.1002/Mrm.24840  0.734
2014 Nien H, Fessler JA. Accelerating ordered-subsets X-ray CT image reconstruction using the linearized augmented Lagrangian framework Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9033. DOI: 10.1117/12.2042686  0.459
2014 McGaffin MG, Fessler JA. Fast edge-preserving image denoising via group coordinate descent on the GPU Proceedings of Spie - the International Society For Optical Engineering. 9020. DOI: 10.1117/12.2042593  0.404
2014 Schmitt SM, Fessler JA, Fichter GD, Zimdars DA. Model-based, one-sided, time-of-flight terahertz image reconstruction Proceedings of Spie. 9020. DOI: 10.1117/12.2042282  0.48
2014 Muckley MJ, Fessler JA. Fast MR image reconstruction with orthogonal wavelet regularization via shift-variant shrinkage 2014 Ieee International Conference On Image Processing, Icip 2014. 3651-3655. DOI: 10.1109/ICIP.2014.7025741  0.351
2014 Sun H, Grissom WA, Fessler JA. Regularized estimation of Bloch-Siegert b1+ maps in MRI 2014 Ieee International Conference On Image Processing, Icip 2014. 3646-3650. DOI: 10.1109/ICIP.2014.7025740  0.331
2014 Weller DS, Pnueli A, Radzyner O, Divon G, Eldar YC, Fessler JA. Phase retrieval of sparse signals using optimization transfer and ADMM 2014 Ieee International Conference On Image Processing, Icip 2014. 1342-1346. DOI: 10.1109/ICIP.2014.7025268  0.688
2013 Chun SY, Fessler JA, Dewaraja YK. Post-reconstruction non-local means filtering methods using CT side information for quantitative SPECT. Physics in Medicine and Biology. 58: 6225-40. PMID 23956327 DOI: 10.1088/0031-9155/58/17/6225  0.6
2013 Kim D, Pal D, Thibault JB, Fessler JA. Accelerating ordered subsets image reconstruction for X-ray CT using spatially nonuniform optimization transfer. Ieee Transactions On Medical Imaging. 32: 1965-78. PMID 23751959 DOI: 10.1109/Tmi.2013.2266898  0.45
2013 Nuyts J, De Man B, Fessler JA, Zbijewski W, Beekman FJ. Modelling the physics in the iterative reconstruction for transmission computed tomography. Physics in Medicine and Biology. 58: R63-96. PMID 23739261 DOI: 10.1088/0031-9155/58/12/R63  0.446
2013 Ramani S, Weller DS, Nielsen JF, Fessler JA. Non-cartesian MRI reconstruction with automatic regularization Via Monte-Carlo SURE. Ieee Transactions On Medical Imaging. 32: 1411-22. PMID 23591478 DOI: 10.1109/Tmi.2013.2257829  0.74
2013 Matakos A, Ramani S, Fessler JA. Accelerated edge-preserving image restoration without boundary artifacts. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. 22: 2019-29. PMID 23372080 DOI: 10.1109/Tip.2013.2244218  0.447
2013 Allison MJ, Ramani S, Fessler JA. Accelerated regularized estimation of MR coil sensitivities using augmented Lagrangian methods. Ieee Transactions On Medical Imaging. 32: 556-64. PMID 23192524 DOI: 10.1109/Tmi.2012.2229711  0.464
2013 Chun SY, Fessler JA, Dewaraja YK. Correction for collimator-detector response in SPECT using point spread function template. Ieee Transactions On Medical Imaging. 32: 295-305. PMID 23086521 DOI: 10.1109/Tmi.2012.2225441  0.579
2013 Chun SY, Fessler JA. Noise properties of motion-compensated tomographic image reconstruction methods. Ieee Transactions On Medical Imaging. 32: 141-52. PMID 22759442 DOI: 10.1109/Tmi.2012.2206604  0.612
2013 Weller DS, Noll DC, Fessler JA. Prospective motion correction for functional MRI using sparsity and Kalman filtering Proceedings of Spie - the International Society For Optical Engineering. 8858. DOI: 10.1117/12.2023074  0.764
2013 Nien H, Fessler JA. Splitting-based statistical X-ray CT image reconstruction with blind gain correction Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8668. DOI: 10.1117/12.2007430  0.511
2013 Lingenfelter DJ, Fessler JA, Scott CD, He Z. Source detection performance prediction for a CdZnTe array Ieee Transactions On Nuclear Science. 60: 204-212. DOI: 10.1109/Tns.2012.2236358  0.787
2013 Cho JH, Fessler JA. Quadratic regularization design for 3D axial CT: Towards isotropic noise Ieee Nuclear Science Symposium Conference Record. DOI: 10.1109/NSSMIC.2013.6829355  0.328
2013 Kim D, Fessler JA. Ordered subsets acceleration using relaxed momentum for X-ray CT image reconstruction Ieee Nuclear Science Symposium Conference Record. DOI: 10.1109/NSSMIC.2013.6829298  0.354
2013 Weller DS, Ramani S, Nielsen JF, Fessler JA. Sure-based parameter selection for parallel MRI reconstruction using GRAPPA and sparsity Proceedings - International Symposium On Biomedical Imaging. 954-957. DOI: 10.1109/ISBI.2013.6556634  0.693
2013 Zhao F, Fessler JA, Wright SM, Rispoli JV, Noll DC. Optimized linear combinations of channels for complex multiple-coil B 1 field estimation with Bloch-Siegert B1 mapping in MRI Proceedings - International Symposium On Biomedical Imaging. 942-945. DOI: 10.1109/ISBI.2013.6556631  0.554
2013 Ramani S, Fessler JA. Accelerated noncartesian sense reconstruction using a majorize-minimize algorithm combining variable-splitting Proceedings - International Symposium On Biomedical Imaging. 704-707. DOI: 10.1109/ISBI.2013.6556572  0.364
2013 Sun H, Weller DS, Chu A, Ramani S, Yoon D, Nielsen JF, Fessler JA. Spoke pulse design in magnetic resonance imaging using greedy minimax algorithm Proceedings - International Symposium On Biomedical Imaging. 696-699. DOI: 10.1109/ISBI.2013.6556570  0.655
2013 Kim D, Ramani S, Fessler JA. Ordered subsets with momentum for accelerated X-ray CT image reconstruction Icassp, Ieee International Conference On Acoustics, Speech and Signal Processing - Proceedings. 920-923. DOI: 10.1109/ICASSP.2013.6637783  0.338
2012 Kim JK, Fessler JA, Zhang Z. Forward-Projection Architecture for Fast Iterative Image Reconstruction in X-ray CT. Ieee Transactions On Signal Processing : a Publication of the Ieee Signal Processing Society. 60: 5508-5518. PMID 23087589 DOI: 10.1109/Tsp.2012.2208636  0.617
2012 Yoon D, Fessler JA, Gilbert AC, Noll DC. Fast joint design method for parallel excitation radiofrequency pulse and gradient waveforms considering off-resonance. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 68: 278-85. PMID 22555857 DOI: 10.1002/Mrm.24311  0.577
2012 Zhao F, Noll DC, Nielsen JF, Fessler JA. Separate magnitude and phase regularization via compressed sensing. Ieee Transactions On Medical Imaging. 31: 1713-23. PMID 22552571 DOI: 10.1109/Tmi.2012.2196707  0.59
2012 Ramani S, Liu Z, Rosen J, Nielsen JF, Fessler JA. Regularization parameter selection for nonlinear iterative image restoration and MRI reconstruction using GCV and SURE-based methods. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. 21: 3659-72. PMID 22531764 DOI: 10.1109/Tip.2012.2195015  0.484
2012 Chun SY, Fessler JA. Spatial resolution properties of motion-compensated tomographic image reconstruction methods. Ieee Transactions On Medical Imaging. 31: 1413-25. PMID 22481813 DOI: 10.1109/Tmi.2012.2192133  0.638
2012 Ramani S, Fessler JA. A splitting-based iterative algorithm for accelerated statistical X-ray CT reconstruction. Ieee Transactions On Medical Imaging. 31: 677-88. PMID 22084046 DOI: 10.1109/Tmi.2011.2175233  0.466
2012 Siewerdsen J, Fessler J, Myers K. MO-F-217BCD-01: Assessment of Image Quality in the New CT Medical Physics. 39: 3878-3878. DOI: 10.1118/1.4735835  0.458
2012 Ramani S, Rosen J, Liu Z, Fessler JA. Iterative weighted risk estimation for nonlinear image restoration with analysis priors Proceedings of Spie - the International Society For Optical Engineering. 8296. DOI: 10.1117/12.915643  0.454
2012 Cho JH, Fessler JA. Accelerating ordered-subsets image reconstruction for X-ray CT using double surrogates Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8313. DOI: 10.1117/12.911531  0.489
2012 McGaffin MG, Ramani S, Fessler JA. Reduced memory augmented Lagrangian algorithm for 3D iterative X-ray CT image reconstruction Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8313. DOI: 10.1117/12.910941  0.468
2012 Cho JH, Ramani S, Fessler JA. Alternating minimization approach for multi-frame image reconstruction 2012 Ieee Statistical Signal Processing Workshop, Ssp 2012. 225-228. DOI: 10.1109/SSP.2012.6319667  0.347
2012 Chun SY, Fessler JA, Dewaraja YK. Non-local means methods using CT side information for I-131 SPECT image reconstruction Ieee Nuclear Science Symposium Conference Record. 3362-3366. DOI: 10.1109/NSSMIC.2012.6551766  0.619
2012 Schmitt SM, Fessler JA. Fast variance computation for quadratically penalized iterative reconstruction of 3D axial CT images Ieee Nuclear Science Symposium Conference Record. 3287-3292. DOI: 10.1109/NSSMIC.2012.6551749  0.4
2012 Lingenfelter DJ, Fessler JA, Scott CD, He Z. Detection performance prediction for CdZnTe array Ieee Nuclear Science Symposium Conference Record. 4616-4621. DOI: 10.1109/NSSMIC.2011.6154745  0.787
2012 Ramani S, Fessler JA. Statistical X-ray CT reconstruction using a splitting-based iterative algorithm with orthonormal wavelets Proceedings - International Symposium On Biomedical Imaging. 1008-1011. DOI: 10.1109/ISBI.2012.6235728  0.346
2012 Allison MJ, Ramani S, Fessler JA. Regularized MR coil sensitivity estimation using augmented Lagrangian methods Proceedings - International Symposium On Biomedical Imaging. 394-397. DOI: 10.1109/ISBI.2012.6235567  0.355
2012 Matakos A, Ramani S, Fessler JA. Image restoration using non-circulant shift-invariant system models Proceedings - International Conference On Image Processing, Icip. 3061-3064. DOI: 10.1109/ICIP.2012.6467546  0.303
2012 Ramani S, Nielsen JF, Fessler JA. Cross-validation and predicted risk estimation for nonlinear iterative reweighted least-squares MRI reconstruction Proceedings - International Conference On Image Processing, Icip. 2049-2052. DOI: 10.1109/ICIP.2012.6467293  0.35
2011 Kublik C, Esedoḡlu S, Fessler JA. ALGORITHMS FOR AREA PRESERVING FLOWS. Siam Journal On Scientific Computing : a Publication of the Society For Industrial and Applied Mathematics. 33: 2382-2401. PMID 23243382 DOI: 10.1137/100815542  0.311
2011 Ramani S, Fessler JA. Parallel MR image reconstruction using augmented Lagrangian methods. Ieee Transactions On Medical Imaging. 30: 694-706. PMID 21095861 DOI: 10.1109/Tmi.2010.2093536  0.463
2011 He X, Cheng L, Fessler JA, Frey EC. Regularized image reconstruction algorithms for dual-isotope myocardial perfusion SPECT (MPS) imaging using a cross-tracer prior. Ieee Transactions On Medical Imaging. 30: 1169-83. PMID 20952334 DOI: 10.1109/Tmi.2010.2087031  0.479
2011 Long Y, Fessler J, Balter J. WE-C-110-06: Two-Material Decomposition from a Single CT Scan Using Statistical Image Reconstruction Medical Physics. 38: 3810-3810. DOI: 10.1118/1.3613345  0.632
2011 Fessler J. TU-A-211-01: Iterative Image Reconstruction for CT Medical Physics. 38: 3744-3744. DOI: 10.1118/1.3613090  0.462
2011 Lu Y, Chan HP, Fessler JA, Hadjiiski L, Wei J, Goodsitt MM. Adaptive diffusion regularization for enhancement of microcalcifications in digital breast tomosynthesis (DBT) reconstruction Proceedings of Spie. 7961: 796117. DOI: 10.1117/12.878096  0.37
2011 Lingenfelter DJ, Fessler JA, Scott CD, He Z. Asymptotic source detection performance of gamma-ray imaging systems under model mismatch Ieee Transactions On Signal Processing. 59: 5141-5151. DOI: 10.1109/Tsp.2011.2162326  0.804
2011 Huh W, Fessler JA. Iterative image reconstruction for dual-energy X-ray CT using regularized material sinogram estimates Proceedings - International Symposium On Biomedical Imaging. 1512-1515. DOI: 10.1109/ISBI.2011.5872688  0.368
2011 Chun SY, Fessler JA. Regularization design for isotropic spatial resolution in motion-compensated image reconstruction Proceedings - International Symposium On Biomedical Imaging. 1500-1503. DOI: 10.1109/ISBI.2011.5872685  0.555
2011 Kim D, Fessler JA. Accelerated ordered-subsets algorithm based on separable quadratic surrogates for regularized image reconstruction in X-ray CT Proceedings - International Symposium On Biomedical Imaging. 1134-1137. DOI: 10.1109/ISBI.2011.5872601  0.317
2011 Matakos A, Fessler JA. Dynamic MR image and fieldmap joint reconstruction accounting for through-plane fieldmap gradients Proceedings - International Symposium On Biomedical Imaging. 393-396. DOI: 10.1109/ISBI.2011.5872431  0.357
2011 Ramani S, Fessler JA. Regularized parallel MRI reconstruction using an alternating direction method of multipliers Proceedings - International Symposium On Biomedical Imaging. 385-388. DOI: 10.1109/ISBI.2011.5872429  0.338
2011 Kim JK, Zhang Z, Fessler JA. Hardware acceleration of iterative image reconstruction for X-ray computed tomography Icassp, Ieee International Conference On Acoustics, Speech and Signal Processing - Proceedings. 1697-1700. DOI: 10.1109/ICASSP.2011.5946827  0.339
2010 Long Y, Fessler JA, Balter JM. Accuracy estimation for projection-to-volume targeting during rotational therapy: A feasibility study. Medical Physics. 37: 2480-2490. PMID 28512939 DOI: 10.1118/1.3425998  0.622
2010 Fessler JA. MODEL-BASED IMAGE RECONSTRUCTION FOR MRI. Ieee Signal Processing Magazine. 27: 81-89. PMID 21135916 DOI: 10.1109/Msp.2010.936726  0.488
2010 Long Y, Fessler JA, Balter JM. Accuracy estimation for projection-to-volume targeting during rotational therapy: a feasibility study. Medical Physics. 37: 2480-90. PMID 20632559 DOI: 10.1118/1.3425998  0.653
2010 Long Y, Fessler JA, Balter JM. 3D forward and back-projection for X-ray CT using separable footprints. Ieee Transactions On Medical Imaging. 29: 1839-50. PMID 20529732 DOI: 10.1109/Tmi.2010.2050898  0.706
2010 Valenzuela JR, Fessler JA, Paxman RG. Joint estimation of Stokes images and aberrations from phase-diverse polarimetric measurements. Journal of the Optical Society of America. a, Optics, Image Science, and Vision. 27: 1185-93. PMID 20448786 DOI: 10.1364/Josaa.27.001185  0.8
2010 Dewaraja YK, Koral KF, Fessler JA. Regularized reconstruction in quantitative SPECT using CT side information from hybrid imaging. Physics in Medicine and Biology. 55: 2523-39. PMID 20393233 DOI: 10.1088/0031-9155/55/9/007  0.413
2010 Lingenfelter DJ, Fessler JA, Scott CD, He Z. Benefits of position-sensitive detectors for radioactive source detection Ieee Transactions On Signal Processing. 58: 4473-4483. DOI: 10.1109/Tsp.2010.2051805  0.781
2010 Jaworski JM, Wahl CG, Wang W, Fessler JA, He Z. Model-based reconstruction of spectral and spatial source distribution from objects with known motion Ieee Nuclear Science Symposium Conference Record. 1518-1524. DOI: 10.1109/Tns.2013.2278283  0.397
2010 Lingenfelter DJ, Fessler JA, Scott CD, He Z. Predicting ROC curves for source detection under model mismatch Ieee Nuclear Science Symposium Conference Record. 1092-1095. DOI: 10.1109/NSSMIC.2010.5873935  0.797
2010 Chun SY, Schretter C, Fessler JA. Sufficient condition for local invertibility of spatio-temporal 4D b-spline deformations 2010 7th Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Isbi 2010 - Proceedings. 1221-1224. DOI: 10.1109/ISBI.2010.5490215  0.602
2010 Matakos A, Fessler JA. Joint estimation of image and fieldmap in parallel MRI using single-shot acquisitions 2010 7th Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Isbi 2010 - Proceedings. 984-987. DOI: 10.1109/ISBI.2010.5490153  0.383
2010 Fessler JA. Optimization transfer approach to joint registration /reconstruction for motion-compensated image reconstruction 2010 7th Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Isbi 2010 - Proceedings. 596-599. DOI: 10.1109/ISBI.2010.5490108  0.356
2010 Funai A, Fessler JA. Cramér Rao Bound analysis of joint B1/T1 mapping methods in MRI 2010 7th Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Isbi 2010 - Proceedings. 712-715. DOI: 10.1109/ISBI.2010.5490075  0.764
2009 Chun SY, Fessler JA. A simple regularizer for B-spline nonrigid image registration that encourages local invertibility. Ieee Journal of Selected Topics in Signal Processing. 3: 159-169. PMID 21179392 DOI: 10.1109/Jstsp.2008.2011116  0.641
2009 Musheinesh MA, Divin CJ, Fessler JA, Norris TB. Time-reversal and model-based imaging in a THz waveguide. Optics Express. 17: 13663-70. PMID 19654774 DOI: 10.1364/Oe.17.013663  0.454
2009 Ruan D, Fessler JA, Balter JM, Keall PJ. Real-time profiling of respiratory motion: Baseline drift, frequency variation and fundamental pattern change Physics in Medicine and Biology. 54: 4777-4792. PMID 19622852 DOI: 10.1088/0031-9155/54/15/009  0.562
2009 Joshi A, Koeppe RA, Fessler JA. Reducing between scanner differences in multi-center PET studies. Neuroimage. 46: 154-9. PMID 19457369 DOI: 10.1016/J.Neuroimage.2009.01.057  0.592
2009 Grissom WA, Xu D, Kerr AB, Fessler JA, Noll DC. Fast large-tip-angle multidimensional and parallel RF pulse design in MRI. Ieee Transactions On Medical Imaging. 28: 1548-59. PMID 19447704 DOI: 10.1109/Tmi.2009.2020064  0.551
2009 Joshi AD, Koeppe RA, Fessler JA, Kilbourn MR. Signal separation and parameter estimation in noninvasive dual-tracer PET scans using reference-region approaches Journal of Cerebral Blood Flow and Metabolism. 29: 1346-1357. PMID 19401708 DOI: 10.1038/Jcbfm.2009.53  0.592
2009 Valenzuela JR, Fessler JA. Joint reconstruction of Stokes images from polarimetric measurements. Journal of the Optical Society of America. a, Optics, Image Science, and Vision. 26: 962-8. PMID 19340271 DOI: 10.1364/Josaa.26.000962  0.811
2009 Noh J, Fessler JA, Kinahan PE. Statistical sinogram restoration in dual-energy CT for PET attenuation correction. Ieee Transactions On Medical Imaging. 28: 1688-702. PMID 19336292 DOI: 10.1109/Tmi.2009.2018283  0.598
2009 Shi HR, Fessler JA. Quadratic regularization design for 2-D CT. Ieee Transactions On Medical Imaging. 28: 645-56. PMID 19272993 DOI: 10.1109/Tmi.2008.2007366  0.7
2009 Yip CY, Yoon D, Olafsson V, Lee S, Grissom WA, Fessler JA, Noll DC. Spectral-spatial pulse design for through-plane phase precompensatory slice selection in T2*-weighted functional MRI. Magnetic Resonance in Medicine. 61: 1137-47. PMID 19267346 DOI: 10.1002/Mrm.21938  0.562
2009 Bhagalia R, Fessler JA, Kim B. Accelerated nonrigid intensity-based image registration using importance sampling. Ieee Transactions On Medical Imaging. 28: 1208-16. PMID 19211343 DOI: 10.1109/Tmi.2009.2013136  0.827
2009 Ruan D, Fessler J, Balter J, Keall P. TU-C-303A-03: Real-Time Profiling of Respiratory Motion and Its Application to Continuous Horizon Prediction Medical Physics. 36: 2724-2725. DOI: 10.1118/1.3182340  0.587
2009 Lingenfelter DJ, Fessler JA, He Z. Sparsity regularization for image reconstruction with poisson data Proceedings of Spie - the International Society For Optical Engineering. 7246. DOI: 10.1117/12.816961  0.826
2009 Bhagalia RR, Fessler JA, Kim B, Meyer CR. Improved fMRI Time-series Registration Using Joint Probability Density Priors Proceedings of Spie. 7259. DOI: 10.1117/12.811421  0.797
2009 Chun SY, Fessler JA, Kessler ML. A simple penalty that encourages local invertibility and considers sliding effects for respiratory motion Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7259. DOI: 10.1117/12.811181  0.608
2009 Chun SY, Fessler JA. Joint image reconstruction and nonrigid motion estimation with a simple penalty that encourages local invertibility Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7258. DOI: 10.1117/12.811067  0.666
2009 Lingenfelter DJ, Fessler JA, Scott CD, He Z. Benefits of position-sensitive detectors for source detection with known background Ieee Nuclear Science Symposium Conference Record. 636-640. DOI: 10.1109/NSSMIC.2009.5402005  0.791
2009 Chun SY, Fessler JA. Spatial resolution and noise properties of regularized motion-compensated image reconstruction Proceedings - 2009 Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Isbi 2009. 863-866. DOI: 10.1109/ISBI.2009.5193189  0.578
2009 Huh W, Fessler JA. Model-based image reconstruction for dual-energy x-rAY CT With fast kvp switching Proceedings - 2009 Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Isbi 2009. 326-329. DOI: 10.1109/ISBI.2009.5193050  0.332
2009 Kowash BR, Wehe DK, Fessler JA. A rotating modulation imager for locating mid-range point sources Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 602: 477-483. DOI: 10.1016/J.Nima.2008.12.233  0.384
2008 Funai AK, Fessler JA, Yeo DT, Olafsson VT, Noll DC. Regularized field map estimation in MRI. Ieee Transactions On Medical Imaging. 27: 1484-94. PMID 18815100 DOI: 10.1109/Tmi.2008.923956  0.797
2008 Olafsson VT, Noll DC, Fessler JA. Fast joint reconstruction of dynamic R2* and field maps in functional MRI. Ieee Transactions On Medical Imaging. 27: 1177-88. PMID 18753040 DOI: 10.1109/Tmi.2008.917247  0.633
2008 Ruan D, Fessler JA, Balter JM, Berbeco RI, Nishioka S, Shirato H. Inference of hysteretic respiratory tumor motion from external surrogates: a state augmentation approach. Physics in Medicine and Biology. 53: 2923-36. PMID 18460744 DOI: 10.1088/0031-9155/53/11/011  0.566
2008 Zeng R, Fessler JA, Balter JM, Balter PA. Iterative sorting for four-dimensional CT images based on internal anatomy motion. Medical Physics. 35: 917-26. PMID 18404928 DOI: 10.1118/1.2837286  0.728
2008 Ruan D, Fessler JA, Balter JM. Mean position tracking of respiratory motion. Medical Physics. 35: 782-92. PMID 18383701 DOI: 10.1118/1.2825616  0.568
2008 Grissom WA, Yip CY, Wright SM, Fessler JA, Noll DC. Additive angle method for fast large-tip-angle RF pulse design in parallel excitation. Magnetic Resonance in Medicine. 59: 779-87. PMID 18383288 DOI: 10.1002/Mrm.21510  0.539
2008 Yeo DT, Fessler JA, Kim B. Concurrent correction of geometric distortion and motion using the map-slice-to-volume method in echo-planar imaging. Magnetic Resonance Imaging. 26: 703-14. PMID 18280077 DOI: 10.1016/J.Mri.2007.11.001  0.403
2008 Joshi A, Fessler JA, Koeppe RA. Improving PET receptor binding estimates from Logan plots using principal component analysis. Journal of Cerebral Blood Flow and Metabolism : Official Journal of the International Society of Cerebral Blood Flow and Metabolism. 28: 852-65. PMID 18059434 DOI: 10.1038/Sj.Jcbfm.9600584  0.597
2008 Ruan D, Fessler J, Balter J, Berbeco R, Nishioka S, Shirato H. TU-C-351-10: Inference of Hysteretic Respiratory Tumour Motion From External Surrogates: A State Augmentation Approach Medical Physics. 35: 2893-2893. DOI: 10.1118/1.2962485  0.564
2008 Valenzuela JR, Fessler JA. Regularized estimation of Stokes images from polarimetric measurements Proceedings of Spie - the International Society For Optical Engineering. 6814. DOI: 10.1117/12.777882  0.809
2008 Noh J, Fessler JA, Kinahan PE. Low-dose dual-energy computed tomography for PET attenuation correction with statistical sinogram restoration Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6913. DOI: 10.1117/12.769855  0.304
2008 Se YC, Fessler JA. Regularized methods for topology-preserving smooth nonrigid image registration using B-spline basis 2008 5th Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Proceedings, Isbi. 1099-1102. DOI: 10.1109/ISBI.2008.4541192  0.308
2008 Joshi AD, Fessler J, Koeppe R. Signal separation and parameter estimation in non-invasive dual-tracer PET Neuroimage. 41: T25. DOI: 10.1016/J.Neuroimage.2008.04.199  0.302
2007 Yendiki A, Fessler JA. Analysis of observer performance in unknown-location tasks for tomographic image reconstruction. Journal of the Optical Society of America. a, Optics, Image Science, and Vision. 24: B99-B109. PMID 18059919 DOI: 10.1364/Josaa.24.000B99  0.693
2007 Ruan D, Fessler JA, Balter JM. Real-time prediction of respiratory motion based on local regression methods Physics in Medicine and Biology. 52: 7137-7152. PMID 18029998 DOI: 10.1088/0031-9155/52/23/024  0.573
2007 Jacobson MW, Fessler JA. An expanded theoretical treatment of iteration-dependent majorize-minimize algorithms. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. 16: 2411-22. PMID 17926925 DOI: 10.1109/Tip.2007.904387  0.369
2007 Yip CY, Grissom WA, Fessler JA, Noll DC. Joint design of trajectory and RF pulses for parallel excitation. Magnetic Resonance in Medicine. 58: 598-604. PMID 17763362 DOI: 10.1002/Mrm.21262  0.544
2007 Fessler JA. On NUFFT-based gridding for non-Cartesian MRI. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 188: 191-5. PMID 17689121 DOI: 10.1016/J.Jmr.2007.06.012  0.419
2007 Yeo DT, Chenevert TL, Fessler JA, Kim B. Zero and first-order phase shift correction for field map estimation with dual-echo GRE using bipolar gradients. Magnetic Resonance Imaging. 25: 1263-71. PMID 17442524 DOI: 10.1016/J.Mri.2007.02.001  0.343
2007 Zhang-O'Connor Y, Fessler JA. Fast predictions of variance images for fan-beam transmission tomography with quadratic regularization. Ieee Transactions On Medical Imaging. 26: 335-46. PMID 17354639 DOI: 10.1109/Tmi.2006.887368  0.817
2007 Zeng R, Fessler JA, Balter JM. Estimating 3-D respiratory motion from orbiting views by tomographic image registration. Ieee Transactions On Medical Imaging. 26: 153-63. PMID 17304730 DOI: 10.1109/Tmi.2006.889719  0.693
2007 Ruan D, Fessler J, Balter J. TU-C-M100J-08: Objective Characterization, Estimation and Prediction for Modeling Breathing-Related Movement Medical Physics. 34: 2546-2547. DOI: 10.1118/1.2761339  0.583
2007 Zeng R, Balter J, Fessler J. SU-FF-J-87: Iterative Sorting for 4D CT Images Based On Internal Anatomic Motion Medical Physics. 34: 2388-2388. DOI: 10.1118/1.2760592  0.695
2007 Zhang-O'Connor Y, Fessler JA. Fast variance predictions for 3D cone-beam CT with quadratic regularization Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6510. DOI: 10.1117/12.710312  0.771
2007 Shi H, Fessler JA. Quadratic regularization design for iterative reconstruction in 3D multi-slice axial CT Ieee Nuclear Science Symposium Conference Record. 5: 2834-2836. DOI: 10.1109/NSSMIC.2006.356467  0.366
2007 Fessler JA, Noll DC. Model-based MR image reconstruction with compensation for through-plane field inhomogeneity 2007 4th Ieee International Symposium On Biomedical Imaging: From Nano to Macro - Proceedings. 920-923. DOI: 10.1109/ISBI.2007.357003  0.619
2007 Funai A, Fessler JA, Grissom W, Noll DC. Regularized B1+ map estimation in MRI 2007 4th Ieee International Symposium On Biomedical Imaging: From Nano to Macro - Proceedings. 616-619. DOI: 10.1109/ISBI.2007.356927  0.789
2007 Khalsa KA, Fessler JA. Resolution properties in regularized dynamic MRI reconstruction 2007 4th Ieee International Symposium On Biomedical Imaging: From Nano to Macro - Proceedings. 456-459. DOI: 10.1109/ISBI.2007.356887  0.792
2006 Dewaraja YK, Ljungberg M, Fessler JA. 3-D Monte Carlo-Based Scatter Compensation in Quantitative I-131 SPECT Reconstruction. Ieee Transactions On Nuclear Science. 53: 181. PMID 20104252 DOI: 10.1109/Tns.2005.862956  0.41
2006 Yip CY, Fessler JA, Noll DC. Advanced three-dimensional tailored RF pulse for signal recovery in T2*-weighted functional magnetic resonance imaging. Magnetic Resonance in Medicine. 56: 1050-9. PMID 17041911 DOI: 10.1002/Mrm.21048  0.604
2006 Ruan D, Fessler JA, Balter JM, Sonke JJ. Exploring breathing pattern irregularity with projection-based method. Medical Physics. 33: 2491-9. PMID 16898452 DOI: 10.1118/1.2207253  0.556
2006 Grissom W, Yip CY, Zhang Z, Stenger VA, Fessler JA, Noll DC. Spatial domain method for the design of RF pulses in multicoil parallel excitation. Magnetic Resonance in Medicine. 56: 620-9. PMID 16894579 DOI: 10.1002/Mrm.20978  0.557
2006 Kinahan PE, Alessio AM, Fessler JA. Dual energy CT attenuation correction methods for quantitative assessment of response to cancer therapy with PET/CT imaging. Technology in Cancer Research & Treatment. 5: 319-27. PMID 16866562 DOI: 10.1177/153303460600500403  0.454
2006 Feng B, Fessler JA, King MA. Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT. Ieee Transactions On Medical Imaging. 25: 941-9. PMID 16827494 DOI: 10.1109/Tmi.2006.876151  0.443
2006 Zhang-O'Connor Y, Fessler JA. Fourier-based forward and back-projectors in iterative fan-beam tomographic image reconstruction. Ieee Transactions On Medical Imaging. 25: 582-9. PMID 16689262 DOI: 10.1109/Tmi.2006.872139  0.803
2006 Ahn S, Fessler JA, Blatt D, Hero AO. Convergent incremental optimization transfer algorithms: application to tomography. Ieee Transactions On Medical Imaging. 25: 283-96. PMID 16524085 DOI: 10.1109/Tmi.2005.862740  0.61
2006 Yendiki A, Fessler JA. Analysis of observer performance in known-location tasks for tomographic image reconstruction. Ieee Transactions On Medical Imaging. 25: 28-41. PMID 16398412 DOI: 10.1109/Tmi.2005.859714  0.672
2006 Ruan D, Fessler J, Roberson M, Balter J, Kessler M. TU-C-ValA-04: Deformable Registration Using Regularization That Accommodates Local Tissue Rigidity Medical Physics. 33: 2186-2186. DOI: 10.1118/1.2241509  0.613
2006 Ting M, Hero AO, Rugar D, Yip C, Fessler JA. Near-optimal signal detection for finite-state Markov signals with application to magnetic resonance force microscopy Ieee Transactions On Signal Processing. 54: 2049-2062. DOI: 10.1109/Tsp.2006.874413  0.306
2006 Feng B, Fessler JA, Pretorius PH, Beach RD, Zeng GL, King MA. Evaluation of the ordered-subset transmission (OSTR) algorithm for transmission imaging on SPECT systems using axially overlapping cone-beams Ieee Transactions On Nuclear Science. 53: 1221-1229. DOI: 10.1109/Tns.2006.873709  0.449
2006 Yendiki A, Fessler JA. Analysis of unknown-location signal detectability for regularized tomographic image reconstruction 2006 3rd Ieee International Symposium On Biomedical Imaging: From Nano to Macro - Proceedings. 2006: 279-282.  0.665
2006 Jacobson MW, Fessler JA. Joint estimation of respiratory motion and activity in 4D pet using CT side information 2006 3rd Ieee International Symposium On Biomedical Imaging: From Nano to Macro - Proceedings. 2006: 275-278.  0.34
2006 Bhagalia R, Fessler JA, Kim B. Gradient based image registration using importance sampling 2006 3rd Ieee International Symposium On Biomedical Imaging: From Nano to Macro - Proceedings. 2006: 446-449.  0.83
2006 Olafsson V, Fessler JA, Noll DC. Spatial resolution analysis of iterative image reconstruction with separate regularization of real and imaginary parts 2006 3rd Ieee International Symposium On Biomedical Imaging: From Nano to Macro - Proceedings. 2006: 5-8.  0.631
2005 Narayanan R, Fessler JA, Park H, Meyerl CR. Diffeomorphic nonlinear transformations: a local parametric approach for image registration. Information Processing in Medical Imaging : Proceedings of the ... Conference. 19: 174-85. PMID 17354694  0.667
2005 Yip CY, Fessler JA, Noll DC. Iterative RF pulse design for multidimensional, small-tip-angle selective excitation. Magnetic Resonance in Medicine. 54: 908-17. PMID 16155881 DOI: 10.1002/Mrm.20631  0.562
2005 Zeng R, Fessler JA, Balter JM. Respiratory motion estimation from slowly rotating x-ray projections: theory and simulation. Medical Physics. 32: 984-91. PMID 15895581 DOI: 10.1118/1.1879132  0.687
2005 Noll DC, Fessler JA, Sutton BP. Conjugate phase MRI reconstruction with spatially variant sample density correction. Ieee Transactions On Medical Imaging. 24: 325-36. PMID 15754983 DOI: 10.1109/Tmi.2004.842452  0.748
2005 Zeng R, Fessler J, Balter J. TU-D-J-6C-06: 3D Respiratory Motion Estimation From Slowly Rotating 2D-Xray Projection Views Medical Physics. 32: 2095-2095. DOI: 10.1118/1.1998397  0.677
2005 Ruan D, Fessler J, Balter J, Wolthaus J, Sonke J. SU-FF-J-06: Analysis of Periodicity and Complexity of Breathing Patterns for Radiotherapy Medical Physics. 32: 1920-1920. DOI: 10.1118/1.1997552  0.545
2005 Shi H, Fessler JA. Quadratic regularization design for fan beam transmission tomography Progress in Biomedical Optics and Imaging - Proceedings of Spie. 5747: 2023-2033. DOI: 10.1117/12.593412  0.692
2005 Jacobson MW, Fessler JA. Fast interpolation operations in non-rigid image registration Progress in Biomedical Optics and Imaging - Proceedings of Spie. 5747: 764-774. DOI: 10.1117/12.592243  0.317
2005 Fessler JA, Lee S, Olafsson VT, Shi HR, Noll DC. Toeplitz-based iterative image reconstruction for MRI with correction for magnetic field inhomogeneity Ieee Transactions On Signal Processing. 53: 3393-3402. DOI: 10.1109/Tsp.2005.853152  0.777
2005 Yingying Z, Fessler JA, Hsieh J. Fast variance image predictions for quadratically regularized statistical image reconstruction in fan-beam tomography Ieee Nuclear Science Symposium Conference Record. 4: 1929-1932. DOI: 10.1109/NSSMIC.2005.1596709  0.359
2005 Srivastava S, Fessler JA. Simplified statistical image reconstruction algorithm for polyenergetic X-ray CT Ieee Nuclear Science Symposium Conference Record. 3: 1551-1555. DOI: 10.1109/NSSMIC.2005.1596614  0.369
2005 Fessler JA, Chun SY, Huggins JE, Levine SP. Detection of event-related spectral changes in electrocorticograms 2nd International Ieee Embs Conference On Neural Engineering. 2005: 269-272. DOI: 10.1109/CNE.2005.1419609  0.507
2004 Stayman JW, Fessler JA. Efficient calculation of resolution and covariance for penalized-likelihood reconstruction in fully 3-D SPECT. Ieee Transactions On Medical Imaging. 23: 1543-56. PMID 15575411 DOI: 10.1109/Tmi.2004.837790  0.641
2004 Kim J, Fessler JA. Intensity-based image registration using robust correlation coefficients. Ieee Transactions On Medical Imaging. 23: 1430-44. PMID 15554130 DOI: 10.1109/Tmi.2004.835313  0.623
2004 Lee K, Kinahan PE, Fessler JA, Miyaoka RS, Janes M, Lewellen TK. Pragmatic fully 3D image reconstruction for the MiCES mouse imaging PET scanner. Physics in Medicine and Biology. 49: 4563-78. PMID 15552417 DOI: 10.1088/0031-9155/49/19/008  0.469
2004 Yendiki A, Fessler JA. A comparison of rotation- and blob-based system models for 3D SPECT with depth-dependent detector response. Physics in Medicine and Biology. 49: 2157-68. PMID 15248570 DOI: 10.1088/0031-9155/49/11/003  0.712
2004 Sutton BP, Noll DC, Fessler JA. Dynamic field map estimation using a spiral-in/spiral-out acquisition. Magnetic Resonance in Medicine. 51: 1194-204. PMID 15170840 DOI: 10.1002/Mrm.20079  0.72
2004 Ahn S, Fessler JA. Emission image reconstruction for randoms-precorrected PET allowing negative sinogram values. Ieee Transactions On Medical Imaging. 23: 591-601. PMID 15147012 DOI: 10.1109/Tmi.2004.826046  0.643
2004 Sotthivirat S, Fessler JA. Penalized-likelihood image reconstruction for digital holography. Journal of the Optical Society of America. a, Optics, Image Science, and Vision. 21: 737-50. PMID 15139426 DOI: 10.1364/Josaa.21.000737  0.795
2004 Matej S, Fessler JA, Kazantsev IG. Iterative tomographic image reconstruction using Fourier-based forward and back-projectors. Ieee Transactions On Medical Imaging. 23: 401-12. PMID 15084066 DOI: 10.1109/Tmi.2004.824233  0.469
2004 Stayman JW, Fessler JA. Compensation for nonuniform resolution using penalized-likelihood reconstruction in space-variant imaging systems. Ieee Transactions On Medical Imaging. 23: 269-84. PMID 15027520 DOI: 10.1109/Tmi.2003.823063  0.673
2004 Koral KF, Yendiki A, Lin Q, Dewaraja YK, Fessler JA. Determining total I-131 activity within a VoI using SPECT, a UHE collimator, OSEM, and a constant conversion factor Ieee Transactions On Nuclear Science. 51: 611-618. DOI: 10.1109/Tns.2004.829605  0.635
2004 Feng B, Pretorius PH, Bruyant PP, Boening G, Beach RD, Gifford HC, Fessler JA, King MA. Body-and-lungs-outline penalized-likelihood recon-struction of asymmetric cone-beam transmission data acquired with less than complete gantry rotation Journal of Nuclear Cardiology. 11. DOI: 10.1016/J.Nuclcard.2004.06.005  0.435
2004 Yendiki A, Fessler JA. Analytical approach to channelized hotelling observer performance for regularized tomograpic image reconstruction 2004 2nd Ieee International Symposium On Biomedical Imaging: Macro to Nano. 1: 360-363.  0.663
2004 Yendiki A, Fessler JA. Analysis of observer performance in detecting signals with location uncertainty for regularized tomographic image reconstruction Ieee Nuclear Science Symposium Conference Record. 4: 2620-2624.  0.655
2004 Fessler JA, Noll DC. Iterative image reconstruction in MRI with separate magnitude and phase regularization 2004 2nd Ieee International Symposium On Biomedical Imaging: Macro to Nano. 1: 209-212.  0.635
2004 Srivastava S, Fessler JA. Penalized likelihood transmission image reconstruction : Unconstrained monotonic algorithms 2004 2nd Ieee International Symposium On Biomedical Imaging: Macro to Nano. 1: 748-751.  0.322
2004 Ahn S, Fessler JA, Nichols TE, Koeppe RA. Covariance of kinetic parameter estimators based on time activity curve reconstructions: Preliminary study on 1D dynamic imaging 2004 2nd Ieee International Symposium On Biomedical Imaging: Macro to Nano. 1: 368-371.  0.576
2003 Nuyts J, Fessler JA. A penalized-likelihood image reconstruction method for emission tomography, compared to postsmoothed maximum-likelihood with matched spatial resolution. Ieee Transactions On Medical Imaging. 22: 1042-52. PMID 12956260 DOI: 10.1109/Tmi.2003.816960  0.46
2003 Idris A E, Fessler JA. Segmentation-free statistical image reconstruction for polyenergetic x-ray computed tomography with experimental validation. Physics in Medicine and Biology. 48: 2453-77. PMID 12953909 DOI: 10.1088/0031-9155/48/15/314  0.463
2003 Ahn S, Fessler JA. Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms. Ieee Transactions On Medical Imaging. 22: 613-26. PMID 12846430 DOI: 10.1109/Tmi.2003.812251  0.603
2003 Sutton BP, Noll DC, Fessler JA. Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities. Ieee Transactions On Medical Imaging. 22: 178-88. PMID 12715994 DOI: 10.1109/Tmi.2002.808360  0.755
2003 Sotthivirat S, Fessler JA. Relaxed ordered-subset algorithm for penalized-likelihood image restoration. Journal of the Optical Society of America. a, Optics, Image Science, and Vision. 20: 439-49. PMID 12630830 DOI: 10.1364/Josaa.20.000439  0.776
2003 Fessler JA, Sutton BP. Nonuniform fast Fourier transforms using min-max interpolation Ieee Transactions On Signal Processing. 51: 560-574. DOI: 10.1109/Tsp.2002.807005  0.59
2003 Jacobson MW, Fessler JA. Joint estimation of image and deformation parameters in tomographic image reconstruction Ieee Workshop On Statistical Signal Processing Proceedings. 2003: 162-165. DOI: 10.1109/SSP.2003.1289369  0.363
2003 Fessler JA. Analytical approach to regularization design for isotropic spatial resolution Ieee Nuclear Science Symposium Conference Record. 3: 2022-2026.  0.326
2003 Sotthivirat S, Fessler JA. Reconstruction from digital holograms by statistical methods Conference Record of the Asilomar Conference On Signals, Systems and Computers. 2: 1928-1932.  0.782
2003 Jacobson MW, Fessler JA. Joint estimation of image and deformation parameters in motion-corrected PET Ieee Nuclear Science Symposium Conference Record. 5: 3290-3294.  0.36
2002 Sotthivirat S, Fessler JA. Image recovery using partitioned-separable paraboloidal surrogate coordinate ascent algorithms. Ieee Transactions On Image Processing : a Publication of the Ieee Signal Processing Society. 11: 306-17. PMID 18244633 DOI: 10.1109/83.988963  0.767
2002 Elbakri IA, Fessler JA. Statistical image reconstruction for polyenergetic X-ray computed tomography. Ieee Transactions On Medical Imaging. 21: 89-99. PMID 11929108 DOI: 10.1109/42.993128  0.746
2002 Yu DF, Fessler JA. Edge-preserving tomographic reconstruction with nonlocal regularization. Ieee Transactions On Medical Imaging. 21: 159-73. PMID 11929103 DOI: 10.1109/42.993134  0.476
2002 Comtat C, Kinahan PE, Fessler JA, Beyer T, Townsend DW, Defrise M, Michel C. Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels. Physics in Medicine and Biology. 47: 1-20. PMID 11814220 DOI: 10.1088/0031-9155/47/1/301  0.427
2002 Fessler JA, Elbakri I, Sukovic P, Clinthorne NH. Maximum-likelihood dual-energy tomographic image reconstruction Proceedings of Spie - the International Society For Optical Engineering. 4684: 38-49. DOI: 10.1117/12.467189  0.815
2002 Fessler JA, Rogers WL. Spatial resolution properties of penalized-likelihood image reconstruction: Space-invariant tomographs Biomedical Imaging V - Proceedings of the 5th Ieee Embs International Summer School On Biomedical Imaging, Ssbi 2002. DOI: 10.1109/83.535846  0.479
2002 Fessler JA. Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): Applications to tomography Biomedical Imaging V - Proceedings of the 5th Ieee Embs International Summer School On Biomedical Imaging, Ssbi 2002. DOI: 10.1109/83.491322  0.354
2002 Yu DF, Fessler JA. Mean and variance of coincidence counting with deadtime Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 488: 362-374. DOI: 10.1016/S0168-9002(02)00460-6  0.377
2002 Fessler JA, Yendiki A. Channelized Hotelling Observer Performance for Penalized-Likelihood Image Reconstruction Ieee Nuclear Science Symposium and Medical Imaging Conference. 2: 1040-1044.  0.673
2002 Stayman JW, Fessler JA. Fast Methods for Approximation of Resolution and Covariance for SPECT Ieee Nuclear Science Symposium and Medical Imaging Conference. 2: 786-788.  0.593
2002 Jacobson M, Fessler JA. Simultaneous estimation of attenuation and activity images using optimization transfer Ieee Nuclear Science Symposium and Medical Imaging Conference. 4: 2085-2089.  0.315
2002 Nuyts J, Fessler JA. Comparison between post-smoothed maximum-likelihood and penalized-likelihood for image reconstruction with uniform spatial resolution Ieee Nuclear Science Symposium and Medical Imaging Conference. 2: 895-899.  0.375
2001 Kim J, Fessler JA, Lam KL, Balter JM, Ten Haken RK. A feasibility study of mutual information based setup error estimation for radiotherapy. Medical Physics. 28: 2507-17. PMID 11797954 DOI: 10.1118/1.1420395  0.724
2001 Yu DF, Fessler JA, Ficaro EP. Maximum-likelihood transmission image reconstruction for overlapping transmission beams. Ieee Transactions On Medical Imaging. 19: 1094-105. PMID 11204847 DOI: 10.1109/42.896785  0.441
2001 Ghanei A, Soltanian-Zadeh H, Elisevich K, Fessler JA. A knowledge-based deformable surface model with application to segmentation of brain structures in MRI Proceedings of Spie - the International Society For Optical Engineering. 4322: 356-365. DOI: 10.1117/12.431106  0.748
2001 Elbakri IA, Fessler JA. Statistical X-ray computed tomography image reconstruction with beam hardening correction Proceedings of Spie - the International Society For Optical Engineering. 4322: 1-12. DOI: 10.1117/12.430961  0.734
2001 Stayman JW, Fessler JA. Nonnegative definite quadratic penalty design for penalized-likelihood reconstruction Ieee Nuclear Science Symposium and Medical Imaging Conference. 2: 1060-1063.  0.533
2001 Ahn S, Fessler JA. Globally convergent ordered subsets algorithms: Application to tomography Ieee Nuclear Science Symposium and Medical Imaging Conference. 2: 1064-1068.  0.544
2001 Fessler JA, Sutton BP. A min-max approach to the multidimensional nonuniform FFT: Application to tomographic image reconstruction Ieee International Conference On Image Processing. 1: 706-709.  0.613
2000 Stayman JW, Fessler JA. Regularization for uniform spatial resolution properties in penalized-likelihood image reconstruction. Ieee Transactions On Medical Imaging. 19: 601-15. PMID 11026463 DOI: 10.1109/42.870666  0.663
2000 Yu DF, Fessler JA. Mean and variance of single photon counting with deadtime Physics in Medicine and Biology. 45: 2043-2056. PMID 10943937 DOI: 10.1088/0031-9155/45/7/324  0.441
2000 Fessler JA, Erdoǧan H, Wu WB. Exact distribution of edge-preserving MAP estimators for linear signal models with Gaussian measurement noise Ieee Transactions On Image Processing. 9: 1049-1055. DOI: 10.1109/83.846247  0.388
2000 Yu DF, Fessler JA. Three-dimensional non-local edge-preserving regularization for PET transmission reconstruction Ieee Nuclear Science Symposium and Medical Imaging Conference. 2.  0.354
2000 Sotthivirat S, Fessler JA. Partitioned separable paraboloidal surrogate coordinate ascent algorithm for image restoration Ieee International Conference On Image Processing. 1: 109-112.  0.736
1999 Erdoǧan H, Fessler JA. Ordered subsets algorithms for transmission tomography Physics in Medicine and Biology. 44: 2835-2851. PMID 10588288 DOI: 10.1088/0031-9155/44/11/311  0.373
1999 Erdogan H, Fessler JA. Monotonic algorithms for transmission tomography Ieee Transactions On Medical Imaging. 18: 801-814. PMID 10571385 DOI: 10.1109/42.802758  0.388
1999 Yavuz M, Fessler JA. Penalized-likelihood estimators and noise analysis for randoms-precorrected PET transmission scans. Ieee Transactions On Medical Imaging. 18: 665-74. PMID 10534049 DOI: 10.1109/42.796280  0.447
1999 Fessler JA, Booth SD. Conjugate-gradient preconditioning methods for shift-variant PET image reconstruction Ieee Transactions On Image Processing. 8: 688-699. DOI: 10.1109/83.760336  0.475
1999 Wilderman SJ, Clinthorne NH, Fessler JA, Rogers WL. List-mode maximum likelihood reconstruction of compton scatter camera images in nuclear medicine Ieee Nuclear Science Symposium and Medical Imaging Conference. 3: 1716-1720.  0.322
1998 Yavuz M, Fessler JA. Statistical image reconstruction methods for randoms-precorrected PET scans Medical Image Analysis. 2: 369-378. PMID 10072203 DOI: 10.1016/S1361-8415(98)80017-0  0.449
1998 Fessler JA. Spatial resolution and noise tradeoffs in pinhole imaging system design: A density estimation approach Optics Express. 2: 237-253. DOI: 10.1364/Oe.2.000237  0.445
1997 Koral KF, Lin S, Fessler JA, Kaminski MS, Wahl RL. Preliminary results from intensity-based CT-SPECT fusion in I-131 anti-B1 monoclonal-antibody therapy of lymphoma Cancer. 80: 2538-2544. PMID 9406707 DOI: 10.1002/(Sici)1097-0142(19971215)80:12+<2538::Aid-Cncr28>3.0.Co;2-C  0.39
1997 Fessler JA, Ficaro EP, Clinthorne NH, Lange K. Grouped-coordinate ascent algorithms for penalized-likelihood transmission image reconstruction. Ieee Transactions On Medical Imaging. 16: 166-75. PMID 9101326 DOI: 10.1109/42.563662  0.341
1997 Ollinger JM, Fessler JA. Positron-emission tomography Ieee Signal Processing Magazine. 14: 43-55. DOI: 10.1109/79.560323  0.448
1997 Wrobel MC, Clinthorne NH, Fessler JA, Zhang Y, Wilderman SJ, Rogers WL. A proposed method for correcting aperture penetration in high energy slit aperture and pinhole SPECT Ieee Transactions On Nuclear Science. 44: 1564-1570. DOI: 10.1109/23.632733  0.383
1996 Hero AO, Fessler JA, Usman M. Exploring estimator bias-variance tradeoffs using the uniform CR bound Ieee Transactions On Signal Processing. 44: 2026-2041. DOI: 10.1109/78.533723  0.353
1996 Kinahan PE, Fessler JA, Karp JS. Statistical image reconstruction methods in PET with compensation for missing data Ieee Nuclear Science Symposium &Amp; Medical Imaging Conference. 3: 1486-1490.  0.393
1995 Fessler JA. Hybrid Poisson/Polynomial Objective Functions for Tomographic Image Reconstruction from Transmission Scans Ieee Transactions On Image Processing. 4: 1439-1450. DOI: 10.1109/83.465108  0.393
1995 Lange K, Fessler JA. Globally Convergent Algorithms for Maximum a Posteriori Transmission Tomography Ieee Transactions On Image Processing. 4: 1430-1438. DOI: 10.1109/83.465107  0.309
1995 Fessler JA, Hero AO. Penalized Maximum-Likelihood Image Reconstruction Using Space-Alternating Generalized EM Algorithms Ieee Transactions On Image Processing. 4: 1417-1429. DOI: 10.1109/83.465106  0.429
1995 Usman M, Hero AO, Fessler JA. Uniform CR bound: implementation issues and applications Ieee Nuclear Science Symposium &Amp; Medical Imaging Conference. 3: 1443-1447.  0.307
1994 Fessler JA, Hero AO. Space-Alternating Generalized Expectation-Maximization Algorithm Ieee Transactions On Signal Processing. 42: 2664-2677. DOI: 10.1109/78.324732  0.416
1994 Fessler JA. Penalized Weighted Least-Squares image Reconstruction for Positron Emission Tomography Ieee Transactions On Medical Imaging. 13: 290-300. DOI: 10.1109/42.293921  0.435
1994 Chiao PC, Rogers WL, Fessler JA, Clinthorne NH, Hero AO. Model-Based Estimation With Boundary Side Information or Boundary Regularization Ieee Transactions On Medical Imaging. 13: 227-234. DOI: 10.1109/42.293915  0.344
1994 Chiao PC, Rogers WL, Clinthorne NH, Fessler JA, Hero AO. Model-Based Estimation for Dynamic Cardiac Studies Using ECT Ieee Transactions On Medical Imaging. 13: 217-226. DOI: 10.1109/42.293914  0.397
1994 Hero A, Fessler JA. A Recursive Algorithm for Computing Cramer-Rao-Type Bounds on Estimator Covariance Ieee Transactions On Information Theory. 40: 1205-1210. DOI: 10.1109/18.335955  0.388
1992 Fessler JA, Clinthorne NH, Rogers WL. Regularized emission image reconstruction using imperfect side information Ieee Transactions On Nuclear Science. 39: 1464-1471. DOI: 10.1109/23.173225  0.332
1991 Fessler JA. Nonparametric Fixed-Interval Smoothing of Nonlinear Vector-Valued Measurements Ieee Transactions On Signal Processing. 39: 907-913. DOI: 10.1109/78.80913  0.414
1991 Fessler JA. Nonparametric Fixed-Interval Smoothing with Vector Splines Ieee Transactions On Signal Processing. 39: 852-859. DOI: 10.1109/78.80907  0.382
1991 Fessler JA, Macovski A. Object-Based 3-D Reconstruction of Arterial Trees from Magnetic Resonance Angiograms Ieee Transactions On Medical Imaging. 10: 25-39. DOI: 10.1109/42.75608  0.603
1989 Bresler Y, Fessler JA, Macovski A. A Bayesian Approach to Reconstruction from Incomplete Projections of a Multiple Object 3D Domain Ieee Transactions On Pattern Analysis and Machine Intelligence. 11: 840-858. DOI: 10.1109/34.31446  0.731
1988 Bresler Y, Fessler JA, Macovski A. Model-based estimation techniques for 3-D reconstruction from projections Machine Vision and Applications. 1: 115-126. DOI: 10.1007/BF01212276  0.677
Show low-probability matches.