Qinan Bao, Ph.D. - Publications

Affiliations: 
2010 University of California, Los Angeles, Los Angeles, CA 
Area:
Biomedical Engineering, Radiology, General Biophysics

13 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2014 Gu Z, Bao Q, Taschereau R, Wang H, Bai B, Chatziioannou AF. Optimization of the Energy Window for PETbox4, a Preclinical PET Tomograph With a Small Inner Diameter. Ieee Transactions On Nuclear Science. 61: 1164-1173. PMID 25774063 DOI: 10.1109/Tns.2014.2321326  0.451
2012 Goertzen AL, Bao Q, Bergeron M, Blankemeyer E, Blinder S, Cañadas M, Chatziioannou AF, Dinelle K, Elhami E, Jans HS, Lage E, Lecomte R, Sossi V, Surti S, Tai YC, et al. NEMA NU 4-2008 comparison of preclinical PET imaging systems. Journal of Nuclear Medicine : Official Publication, Society of Nuclear Medicine. 53: 1300-9. PMID 22699999 DOI: 10.2967/Jnumed.111.099382  0.449
2011 Zhang H, Bao Q, Vu NT, Silverman RW, Taschereau R, Berry-Pusey BN, Douraghy A, Rannou FR, Stout DB, Chatziioannou AF. Performance evaluation of PETbox: a low cost bench top preclinical PET scanner. Molecular Imaging and Biology : Mib : the Official Publication of the Academy of Molecular Imaging. 13: 949-61. PMID 20812031 DOI: 10.1007/S11307-010-0413-Y  0.622
2011 Lu Y, Machado HB, Bao Q, Stout D, Herschman H, Chatziioannou AF. In vivo mouse bioluminescence tomography with radionuclide-based imaging validation. Molecular Imaging and Biology : Mib : the Official Publication of the Academy of Molecular Imaging. 13: 53-8. PMID 20464517 DOI: 10.1007/S11307-010-0332-Y  0.366
2010 Zhang H, Vu NT, Bao Q, Silverman RW, Berry-Pusey BN, Douraghy A, Williams DA, Rannou FR, Stout DB, Chatziioannou AF. Performance Characteristics of BGO Detectors for a Low Cost Preclinical PET Scanner. Ieee Transactions On Nuclear Science. 57: 1038-1044. PMID 21165154 DOI: 10.1109/Tns.2010.2046753  0.588
2010 Bao Q, Chatziioannou AF. Estimation of the minimum detectable activity of preclinical PET imaging systems with an analytical method. Medical Physics. 37: 6070-83. PMID 21158319 DOI: 10.1118/1.3495817  0.487
2010 Gu Z, Bao Q, Chatziioannou AF. Evaluation of the detection limit at low activity levels for three preclinical PET systems Ieee Nuclear Science Symposium Conference Record. 3619-3621. DOI: 10.1109/NSSMIC.2010.5874486  0.347
2009 Bao Q, Newport D, Chen M, Stout DB, Chatziioannou AF. Performance evaluation of the inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards. Journal of Nuclear Medicine : Official Publication, Society of Nuclear Medicine. 50: 401-8. PMID 19223424 DOI: 10.2967/Jnumed.108.056374  0.575
2009 Zhang H, Vu NT, Bao Q, Silverman RW, Stout DB, Taschereau R, Berry-Pusey BN, Williams DA, Douraghy A, Rannou FR, Phelps ME, Chatziioannou AF. Performance evaluation of PETbox: A low cost bench top PET scanner dedicated to high throughput preclinical imaging Ieee Nuclear Science Symposium Conference Record. 4013-4016. DOI: 10.1109/NSSMIC.2009.5401918  0.631
2008 Chatziioannou AF, Bao Q, Karakatsanis N. System sensitivity in preclinical small animal imaging 2008 5th Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Proceedings, Isbi. 1417-1420. DOI: 10.1109/ISBI.2008.4541272  0.398
2007 Karakatsanis N, Bao Q, Vu N, Chatziioannou A. Investigation of the minimum detectable activity level of a preclinical LSO PET scanner Ieee Nuclear Science Symposium Conference Record. 4: 3133-3138. DOI: 10.1109/NSSMIC.2007.4436792  0.321
2007 Bao Q, Chatziioannou AF. GATE simulation of a BGO based high sensitivity small animal PET scanner Proc. of 2007 Joint Meet. of the 6th Int. Symp. On Noninvasive Functional Source Imaging of the Brain and Heart and the Int. Conf. On Functional Biomedical Imaging, Nfsi and Icfbi 2007. 47-50. DOI: 10.1109/NFSI-ICFBI.2007.4387684  0.411
2005 Bao Q, Kohli V, Rannou FR, Chatziioannou AF. A noise equivalent counts approach for optimizing I-124 imaging performance with a small animal PET scanner Ieee Nuclear Science Symposium Conference Record. 4: 2074-2076. DOI: 10.1109/NSSMIC.2005.1596742  0.351
Show low-probability matches.