Year |
Citation |
Score |
2018 |
Zhou M, Cai H, Li Z, Zhang Y, Liu Z, Tang H, Qiao T, Liu C. Contemporary Results of Endovascular Repair of Isolated Abdominal Aortic Dissection with Unibody Bifurcated Stent-grafts. Annals of Vascular Surgery. PMID 29421419 DOI: 10.1016/j.avsg.2017.10.035 |
0.355 |
|
2011 |
Li Z, Kleinstreuer C. Airflow analysis in the alveolar region using the lattice-Boltzmann method. Medical & Biological Engineering & Computing. 49: 441-51. PMID 21308417 DOI: 10.1007/S11517-011-0743-1 |
0.502 |
|
2009 |
Cui L, Su P, Li Z, Lv X. Endovascular Treatment of Fusiform and Wide-Necked Intracranial Aneurysms with the Neuroform 3TM and Detachable Coils. The Neuroradiology Journal. 22: 92-101. PMID 24206958 |
0.337 |
|
2008 |
Kleinstreuer C, Zhang Z, Li Z. Modeling airflow and particle transport/deposition in pulmonary airways. Respiratory Physiology & Neurobiology. 163: 128-38. PMID 18674643 DOI: 10.1016/J.Resp.2008.07.002 |
0.411 |
|
2008 |
Kleinstreuer C, Li Z, Basciano CA, Seelecke S, Farber MA. Computational mechanics of Nitinol stent grafts. Journal of Biomechanics. 41: 2370-8. PMID 18644312 DOI: 10.1016/J.Jbiomech.2008.05.032 |
0.568 |
|
2007 |
Kleinstreuer C, Li Z, Farber MA. Fluid-structure interaction analyses of stented abdominal aortic aneurysms. Annual Review of Biomedical Engineering. 9: 169-204. PMID 17362195 DOI: 10.1146/Annurev.Bioeng.9.060906.151853 |
0.601 |
|
2007 |
Li Z, Kleinstreuer C. A comparison between different asymmetric abdominal aortic aneurysm morphologies employing computational fluid-structure interaction analysis European Journal of Mechanics, B/Fluids. 26: 615-631. DOI: 10.1016/J.Euromechflu.2007.03.003 |
0.637 |
|
2006 |
Li Z, Kleinstreuer C. Effects of blood flow and vessel geometry on wall stress and rupture risk of abdominal aortic aneurysms. Journal of Medical Engineering & Technology. 30: 283-97. PMID 16980283 DOI: 10.1080/03091900500217406 |
0.618 |
|
2006 |
Li Z, Kleinstreuer C. Effects of major endoleaks on a stented abdominal aortic aneurysm. Journal of Biomechanical Engineering. 128: 59-68. PMID 16532618 DOI: 10.1115/1.2132376 |
0.627 |
|
2006 |
Kleinstreuer C, Li Z. Analysis and computer program for rupture-risk prediction of abdominal aortic aneurysms. Biomedical Engineering Online. 5: 19. PMID 16529648 DOI: 10.1186/1475-925X-5-19 |
0.587 |
|
2006 |
Li Z, Kleinstreuer C. Computational analysis of type II endoleaks in a stented abdominal aortic aneurysm model. Journal of Biomechanics. 39: 2573-82. PMID 16221475 DOI: 10.1016/J.Jbiomech.2005.09.002 |
0.637 |
|
2006 |
Li Z, Kleinstreuer C. Analysis of biomechanical factors affecting stent-graft migration in an abdominal aortic aneurysm model. Journal of Biomechanics. 39: 2264-73. PMID 16153654 DOI: 10.1016/J.Jbiomech.2005.07.010 |
0.632 |
|
2005 |
Li Z, Kleinstreuer C, Farber M. Computational analysis of biomechanical contributors to possible endovascular graft failure. Biomechanics and Modeling in Mechanobiology. 4: 221-34. PMID 16270200 DOI: 10.1007/S10237-005-0003-0 |
0.636 |
|
2005 |
Li Z, Kleinstreuer C. Fluid-structure interaction effects on sac-blood pressure and wall stress in a stented aneurysm. Journal of Biomechanical Engineering. 127: 662-71. PMID 16121537 DOI: 10.1115/1.1934040 |
0.647 |
|
2005 |
Li Z, Kleinstreuer C. Blood flow and structure interactions in a stented abdominal aortic aneurysm model. Medical Engineering & Physics. 27: 369-82. PMID 15863346 DOI: 10.1016/J.Medengphy.2004.12.003 |
0.66 |
|
2005 |
Li Z, Kleinstreuer C. A new wall stress equation for aneurysm-rupture prediction. Annals of Biomedical Engineering. 33: 209-13. PMID 15771274 DOI: 10.1007/S10439-005-8979-2 |
0.567 |
|
Show low-probability matches. |