Anthony P. Sanders, Ph.D.

Affiliations: 
2012 Mechanical Engineering University of Utah, Salt Lake City, UT 
Area:
Mechanical Engineering, Biomechanics Biophysics, Biomedical Engineering
Google:
"Anthony Sanders"

Parents

Sign in to add mentor
Rebecca M. Brannon grad student 2012 University of Utah
 (Surrogate theory for Hertzian contact pairs: Application to simplify wear testing of ceramic hip prosthesis materials.)
BETA: Related publications

Publications

You can help our author matching system! If you notice any publications incorrectly attributed to this author, please sign in and mark matches as correct or incorrect.

Sanders AP, Lockard CA, Weisenburger JN, et al. (2016) Using a surrogate contact pair to evaluate polyethylene wear in prosthetic knee joints. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. 104: 133-40
Qiu M, Chyr A, Sanders AP, et al. (2014) Designing prosthetic knee joints with bio-inspired bearing surfaces. Tribology International. 77: 106-110
Chyr A, Qiu M, Speltz J, et al. (2014) A patterned microtexture to reduce friction and increase longevity of prosthetic hip joints. Wear : An International Journal On the Science and Technology of Friction Lubrication and Wear. 315: 51-57
Sanders AP, Raeymaekers B. (2014) The effect of polyethylene creep on tibial insert locking screw loosening and back-out in prosthetic knee joints. Journal of the Mechanical Behavior of Biomedical Materials. 38: 1-5
Sanders AP, Brannon RM. (2014) A simple surrogate test method to rank the wear performance of prospective ceramic materials under hip prosthesis edge-loading conditions. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. 102: 311-21
Chyr A, Sanders AP, Raeymaekers B. (2013) A hybrid apparatus for friction and accelerated wear testing of total knee replacement bearing materials Wear. 308: 54-60
Sanders A, Tibbitts I, Brannon R. (2012) Concomitant evolution of wear and squeaking in dual-severity, lubricated wear testing of ceramic-on-ceramic hip prostheses. Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society. 30: 1377-83
Sanders AP, Dudhiya PJ, Brannon RM. (2012) Thin hard crest on the edge of ceramic acetabular liners accelerates wear in edge loading. The Journal of Arthroplasty. 27: 150-2
Sanders AP, Brannon RM. (2011) Determining a Surrogate Contact Pair in a Hertzian Contact Problem. Journal of Tribology. 133: 2455021-245026
Sanders AP, Brannon RM. (2011) Assessment of the applicability of the Hertzian contact theory to edge-loaded prosthetic hip bearings. Journal of Biomechanics. 44: 2802-8
See more...