Year |
Citation |
Score |
2019 |
Amar LI, Hill MI, Faria M, Guisado D, van Rijn CJM, Leonard EF. Co-current crossflow microfiltration in a microchannel. Biomedical Microdevices. 21: 12. PMID 30725201 DOI: 10.1007/S10544-019-0362-4 |
0.352 |
|
2018 |
Amar LI, Guisado D, Faria M, Jones JP, van Rijn CJM, Hill MI, Leonard EF. Erythrocyte fouling on micro-engineered membranes. Biomedical Microdevices. 20: 55. PMID 29971550 DOI: 10.1007/S10544-018-0297-1 |
0.324 |
|
2018 |
Weeranoppanant N, Amar LI, Tong E, Faria M, Hill MI, Leonard EF. Modeling of fouling in cross-flow microfiltration of suspensions Aiche Journal. 65: 207-213. DOI: 10.1002/Aic.16412 |
0.748 |
|
2017 |
Faria M, Liu Y, Leonard EF. Particle spallation in a microfluidic blood processing device: the problem of using peristaltic pumps and silicon-based microfilters. The International Journal of Artificial Organs. 0. PMID 28623642 DOI: 10.5301/Ijao.5000609 |
0.313 |
|
2012 |
Cacciatore JJ, Leonard EF, Chasin LA. The isolation of CHO cells with a site conferring a high and reproducible transgene amplification rate. Journal of Biotechnology. 164: 346-53. PMID 23376841 DOI: 10.1016/J.Jbiotec.2013.01.016 |
0.607 |
|
2012 |
Dickson MN, Amar L, Hill M, Schwartz J, Leonard EF. A scalable, micropore, platelet rich plasma separation device. Biomedical Microdevices. 14: 1095-102. PMID 22811077 DOI: 10.1007/S10544-012-9675-2 |
0.321 |
|
2011 |
Nora Dickson M, Tsinberg P, Tang Z, Bischoff FZ, Wilson T, Leonard EF. Efficient capture of circulating tumor cells with a novel immunocytochemical microfluidic device. Biomicrofluidics. 5: 34119-3411915. PMID 22662044 DOI: 10.1063/1.3623748 |
0.391 |
|
2010 |
Cacciatore JJ, Chasin LA, Leonard EF. Gene amplification and vector engineering to achieve rapid and high-level therapeutic protein production using the Dhfr-based CHO cell selection system. Biotechnology Advances. 28: 673-81. PMID 20416368 DOI: 10.1016/J.Biotechadv.2010.04.003 |
0.619 |
|
2010 |
Nanne EE, Aucoin CP, Leonard EF. Shear rate and hematocrit effects on the apparent diffusivity of urea in suspensions of bovine erythrocytes. Asaio Journal (American Society For Artificial Internal Organs : 1992). 56: 151-6. PMID 20335796 DOI: 10.1097/Mat.0B013E3181D4Ed0F |
0.749 |
|
2010 |
Nanne EE, Aucoin CP, Leonard EF. Molecular movement of bovine albumin in flowing suspensions of bovineerythrocytes Chemical Engineering Science. 65: 6389-6396. DOI: 10.1016/J.Ces.2010.09.013 |
0.745 |
|
2009 |
Leonard EF. Technical approaches toward ambulatory ESRD therapy. Seminars in Dialysis. 22: 658-60. PMID 20017837 DOI: 10.1111/J.1525-139X.2009.00660.X |
0.312 |
|
2009 |
Aucoin CP, Nanne EE, Leonard EF. Erythrocyte concentration distribution in sheathed microfluidic flows. Asaio Journal (American Society For Artificial Internal Organs : 1992). 55: 423-7. PMID 19584710 DOI: 10.1097/Mat.0B013E3181Ab38Dc |
0.743 |
|
2008 |
Aucoin CP, Leonard EF. Erythrocyte migration and diffusion in broad microfluidic slits Aiche Annual Meeting, Conference Proceedings. |
0.775 |
|
2007 |
Moscato F, Vollkron M, Bergmeister H, Wieselthaler G, Leonard E, Schima H. Left ventricular pressure-volume loop analysis during continuous cardiac assist in acute animal trials. Artificial Organs. 31: 369-76. PMID 17470206 DOI: 10.1111/J.1525-1594.2007.00394.X |
0.498 |
|
2006 |
Leonard EF, Aucoin CP, Nanne EE. Measurement of Diffusion in Flowing Complex Fluids. Colloids and Surfaces. a, Physicochemical and Engineering Aspects. 282: 75-78. PMID 18560469 DOI: 10.1016/J.Colsurfa.2006.02.061 |
0.749 |
|
2006 |
Nanne EE, Choppy KJ, Galea AM, Leonard EF. MEMBRANELESS DIALYSIS: PERFORMANCE OF SECONDARY SEPARATORS Asaio Journal. 52: 73A. DOI: 10.1097/00002480-200603000-00305 |
0.722 |
|
2005 |
Leonard EF, Cortell S, Vitale NG. Membraneless dialysis--is it possible? Contributions to Nephrology. 149: 343-53. PMID 15876858 DOI: 10.1159/000085696 |
0.407 |
|
2005 |
Aucoin CP, Nanne EE, Leonard EF, Vitale NG, West AC. Minimization of cell migration between flowing blood and concurrent miscible layers in a microfluidic environment Aiche Annual Meeting, Conference Proceedings. 2199-2200. |
0.732 |
|
2004 |
Leonard EF, West AC, Shapley NC, Larsen MU. Dialysis without membranes: how and why? Blood Purification. 22: 92-100. PMID 14732817 DOI: 10.1159/000074929 |
0.394 |
|
2002 |
Hadjiiski A, Tcholakova S, Ivanov IB, Gurkov TD, Leonard EF. Gentle film trapping technique with application to drop entry measurements Langmuir. 18: 127-138. DOI: 10.1021/La010751U |
0.303 |
|
2001 |
Kim S, Patrick SM, Braunstein NS, Thomas JL, Leonard EF. Modeling of early events in T cell signal transduction after controlled T cell activation by peptide major histocompatibility complex. Annals of Biomedical Engineering. 29: 373-83. PMID 11400719 DOI: 10.1114/1.1366671 |
0.523 |
|
2001 |
Kim S, Braunstein NS, Leonard EF, Thomas JL. Controlling duration of contact between T cells and antigen-presenting cells. Journal of Immunological Methods. 249: 73-84. PMID 11226465 DOI: 10.1016/S0022-1759(00)00332-X |
0.535 |
|
2001 |
Patrick SM, Kim S, Braunstein NS, Maldarelli CM, Thomas JL, Leonard EF. Controlled cell deformation produces defined areas of contact between cells and ligand-coated surfaces. Annals of Biomedical Engineering. 29: 1-8. PMID 11219503 DOI: 10.1114/1.1332081 |
0.53 |
|
2000 |
Patrick SM, Kim S, Braunstein NS, Thomas JL, Leonard EF. Dependence of T cell activation on area of contact and density of a ligand-coated surface. Journal of Immunological Methods. 241: 97-108. PMID 10915852 DOI: 10.1016/S0022-1759(00)00216-7 |
0.525 |
|
1999 |
Gomez SM, Choy G, Kabir N, Leonard EF. Capture of rare cells in suspension with antibody-coated polystyrene beads Biotechnology Progress. 15: 238-244. PMID 10194399 DOI: 10.1021/Bp990001Z |
0.372 |
|
1998 |
Pfeiffer N, Mandrusov E, Vroman L, Leonard EF. Effects of secondary flow caused by a curved channel on plasma protein adsorption to artificial surfaces Biotechnology Progress. 14: 338-342. PMID 9548789 DOI: 10.1021/Bp970115F |
0.362 |
|
1998 |
Mandrusov E, Yang JD, Pfeiffer N, Vroman L, Puszkin E, Leonard EF. Kinetics of Protein Deposition and Replacement from a Shear Flow Aiche Journal. 44: 233-244. DOI: 10.1002/Aic.690440202 |
0.403 |
|
1997 |
Tamari Y, Lee-Sensiba K, Leonard EF, Tortolani AJ. A dynamic method for setting roller pumps nonocclusively reduces hemolysis and predicts retrograde flow Asaio Journal. 43: 39-52. PMID 9116352 DOI: 10.1097/00002480-199701000-00009 |
0.327 |
|
1996 |
Mandrusov E, Vroman L, Leonard EF. EARLY THROMBOGENESIS FROM SEPARATED FLOWS (SF) IN ARTIFICIAL ORGANS Asaio Journal. 42: 20. DOI: 10.1097/00002480-199603000-00070 |
0.331 |
|
1995 |
Mandrusov E, Houng A, Klein E, Leonard EF. Membrane-based cell affinity chromatography to retrieve viable cells Biotechnology Progress. 11: 208-213. PMID 7766103 DOI: 10.1021/Bp00032A013 |
0.378 |
|
1995 |
Leduc C, Depaola N, Konath S, Vroman L, Leonard EF. Adsorption of proteins out of plasma onto glass from a separated flow Journal of Biomaterials Science, Polymer Edition. 6: 599-608. DOI: 10.1163/156856294X00545 |
0.372 |
|
1993 |
Tamari Y, Lee-Sensiba K, Leonard EF, Parnell V, Tortolani AJ. The effects of pressure and flow on hemolysis caused by Bio-Medicus centrifugal pumps and roller pumps: Guidelines for choosing a blood pump Journal of Thoracic and Cardiovascular Surgery. 106: 997-1007. PMID 8246582 DOI: 10.1016/S0022-5223(19)33970-4 |
0.307 |
|
1992 |
Leonard EF, Vroman L. Is the Vroman effect of importance in the interaction of blood with artificial materials? Journal of Biomaterials Science, Polymer Edition. 3: 95-107. DOI: 10.1163/156856292X00105 |
0.349 |
|
1985 |
Stepner TA, Leonard EF. Evaluation of plasmapheresis membranes Journal of Membrane Science. 23: 285-302. DOI: 10.1016/S0376-7388(00)83147-6 |
0.311 |
|
1984 |
Leonard EF, Vassilieff CS. The deposition of rejected matter in membrane separation processes Chemical Engineering Communications. 30: 209-217. DOI: 10.1080/00986448408911128 |
0.392 |
|
1983 |
Shah SS, Leonard EF. Bloodless evaluation of blood oxygenators Annals of Biomedical Engineering. 11: 67-81. PMID 6354011 DOI: 10.1007/Bf02367492 |
0.312 |
|
1977 |
Leonard EF, Butrille Y, Puszkin S, Kochwa S. Blood elements at foreign surfaces: analysis of inhomogeneities in adsorbed layers of proteins and platelets Annals of the New York Academy of Sciences. 256-269. DOI: 10.1111/J.1749-6632.1977.Tb41771.X |
0.304 |
|
1975 |
Grabowski EF, Derby AR, Koffsky RM, Litwak RS, Leonard EF. An intravascular test device for thromboresistant materials: Analysis and preliminary experimental evaluation Annals of Biomedical Engineering. 3: 322-341. PMID 1220587 DOI: 10.1007/Bf02390977 |
0.362 |
|
1975 |
Benis AM, Nossel HL, Aledort LM, Koffsky RM, Stevenson JF, Leonard EF, Shiang H, Litwak RS. Extracorporeal model for study of factors affecting thrombus formation Thromb.Diathes.Haemorrh.. 34: 127-144. PMID 1103356 DOI: 10.1055/S-0038-1651362 |
0.4 |
|
1974 |
Leonard EF, Jorgensen SB. The analysis of convection and diffusion in capillary beds Annual Review of Biophysics and Bioengineering. 3: 293-339. PMID 4607560 |
0.3 |
|
1972 |
Leonard EF, Grabowski EF, Turitto VT. The role of convection and diffusion on platelet adhesion and aggregation Annals of the New York Academy of Sciences. 201: 329-342. PMID 4509688 DOI: 10.1111/J.1749-6632.1972.Tb16309.X |
0.403 |
|
1972 |
Grabowski EF, Friedman LI, Leonard EF. Effects of shear rate on the diffusion and adhesion of blood platelets to a foreign surface Industrial and Engineering Chemistry Fundamentals. 11: 224-232. DOI: 10.1021/I160042A013 |
0.408 |
|
1972 |
Turitto VT, Benis AM, Leonard EF. Platelet diffusion in flowing blood Industrial and Engineering Chemistry Fundamentals. 11: 216-223. DOI: 10.1021/I160042A012 |
0.477 |
|
1968 |
Kaufmann TG, Leonard EF. Studies of intramembrane transport: A phenomenological approach Aiche Journal. 14: 110-117. DOI: 10.1002/Aic.690140120 |
0.319 |
|
1965 |
Taylor HM, Leonard EF. Axial dispersion during pulsating pipe flow Aiche Journal. 11: 686-689. DOI: 10.1002/Aic.690110422 |
0.369 |
|
1963 |
Farrell MA, Leonard EF. Dispersion in laminar flow by simultaneous convection and diffusion Aiche Journal. 9: 190-195. DOI: 10.1002/Aic.690090211 |
0.484 |
|
1962 |
LEONARD EF. Blood flow in artifical organs--a physical analysis Transactions - American Society For Artificial Internal Organs. 8: 3-10. PMID 14464067 DOI: 10.1097/00002480-196204000-00002 |
0.359 |
|
Show low-probability matches. |