Steven Conolly - Publications

Affiliations: 
Electrical Engineering and Computer Science University of California, Berkeley, Berkeley, CA, United States 
Area:
Medical imaging instrumentation and control

98 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2023 Fung KLB, Colson C, Bryan J, Saayujya C, Mokkarala-Lopez J, Hartley A, Yousuf K, Kuo R, Lu Y, Fellows BD, Chandrasekharan P, Conolly SM. First Superferromagnetic Remanence Characterization and Scan Optimization for Super-Resolution Magnetic Particle Imaging. Nano Letters. PMID 36821385 DOI: 10.1021/acs.nanolett.2c04404  0.402
2021 Tay ZW, Savliwala S, Hensley DW, Fung KLB, Colson C, Fellows BD, Zhou X, Huynh Q, Lu Y, Zheng B, Chandrasekharan P, Rivera-Jimenez SM, Rinaldi-Ramos CM, Conolly SM. Superferromagnetic Nanoparticles Enable Order-of-Magnitude Resolution & Sensitivity Gain in Magnetic Particle Imaging. Small Methods. 5: e2100796. PMID 34927972 DOI: 10.1002/smtd.202100796  0.441
2021 Tay ZW, Chandrasekharan P, Fellows BD, Arrizabalaga IR, Yu E, Olivo M, Conolly SM. Magnetic Particle Imaging: An Emerging Modality with Prospects in Diagnosis, Targeting and Therapy of Cancer. Cancers. 13. PMID 34771448 DOI: 10.3390/cancers13215285  0.425
2020 Lu Y, Rivera-Rodriguez A, Tay ZW, Hensley D, Fung KLB, Colson C, Saayujya C, Huynh Q, Kabuli L, Fellows B, Chandrasekharan P, Rinaldi C, Conolly S. Combining magnetic particle imaging and magnetic fluid hyperthermia for localized and image-guided treatment. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 37: 141-154. PMID 33426994 DOI: 10.1080/02656736.2020.1853252  0.424
2020 Chandrasekharan P, Tay ZW, Hensley D, Zhou XY, Fung BK, Colson C, Lu Y, Fellows BD, Huynh Q, Saayujya C, Yu E, Orendorff R, Zheng B, Goodwill P, Rinaldi C, Conolly S, et al. Using magnetic particle imaging systems to localize and guide magnetic hyperthermia treatment: tracers, hardware, and future medical applications. Theranostics. 10: 2965-2981. PMID 32194849 DOI: 10.7150/Thno.40858  0.454
2019 Tay ZW, Hensley DW, Chandrasekharan P, Zheng B, Conolly SM. Optimization of Drive Parameters for Resolution, Sensitivity and Safety in Magnetic Particle Imaging. Ieee Transactions On Medical Imaging. PMID 31796392 DOI: 10.1109/TMI.2019.2957041  0.311
2019 Tay ZW, Hensley D, Ma J, Chandrasekharan P, Zheng B, Goodwill P, Conolly S. Pulsed Excitation in Magnetic Particle Imaging. Ieee Transactions On Medical Imaging. PMID 30762537 DOI: 10.1109/Tmi.2019.2898202  0.56
2019 Wu LC, Zhang Y, Steinberg G, Qu H, Huang S, Cheng M, Bliss T, Du F, Rao J, Song G, Pisani L, Doyle T, Conolly S, Krishnan K, Grant G, et al. A Review of Magnetic Particle Imaging and Perspectives on Neuroimaging. Ajnr. American Journal of Neuroradiology. PMID 30655254 DOI: 10.3174/Ajnr.A5896  0.532
2018 Tay ZW, Chandrasekharan P, Zhou XY, Yu E, Zheng B, Conolly S. In vivo tracking and quantification of inhaled aerosol using magnetic particle imaging towards inhaled therapeutic monitoring. Theranostics. 8: 3676-3687. PMID 30026874 DOI: 10.7150/Thno.26608  0.476
2018 Chandrasekharan P, Tay ZW, Zhou XY, Yu E, Orendorff R, Hensley D, Huynh Q, Fung KLB, VanHook CC, Goodwill P, Zheng B, Conolly S. A perspective on a rapid and radiation-free tracer imaging modality, Magnetic Particle Imaging, with promise for clinical translation. The British Journal of Radiology. 20180326. PMID 29888968 DOI: 10.1259/Bjr.20180326  0.464
2018 Zhou XY, Tay ZW, Chandrasekharan P, Yu EY, Hensley DW, Orendorff R, Jeffris KE, Mai D, Zheng B, Goodwill PW, Conolly SM. Magnetic particle imaging for radiation-free, sensitive and high-contrast vascular imaging and cell tracking. Current Opinion in Chemical Biology. 45: 131-138. PMID 29754007 DOI: 10.1016/J.Cbpa.2018.04.014  0.472
2018 Wang P, Goodwill PW, Pandit P, Gaudet J, Ross A, Wang J, Yu E, Hensley DW, Doyle TC, Contag CH, Conolly S, Moore A. Magnetic particle imaging of islet transplantation in the liver and under the kidney capsule in mouse models. Quantitative Imaging in Medicine and Surgery. 8: 114-122. PMID 29675353 DOI: 10.21037/Qims.2018.02.06  0.328
2018 Tay ZW, Chandrasekharan P, Chiu-Lam A, Hensley DW, Dhavalikar R, Zhou XY, Yu EY, Goodwill PW, Zheng B, Rinaldi C, Conolly SM. Magnetic Particle Imaging Guided Heating In Vivo using Gradient Fields For Arbitrary Localization of Magnetic Hyperthermia Therapy. Acs Nano. PMID 29570277 DOI: 10.1021/Acsnano.8B00893  0.43
2017 Lu K, Goodwill P, Zheng B, Conolly S. Multi-channel Acquisition for Isotropic Resolution in Magnetic Particle Imaging. Ieee Transactions On Medical Imaging. PMID 29990139 DOI: 10.1109/Tmi.2017.2787500  0.536
2017 Tay ZW, Hensley DW, Vreeland EC, Zheng B, Conolly SM. The Relaxation Wall: Experimental Limits to Improving MPI Spatial Resolution by Increasing Nanoparticle Core size. Biomedical Physics & Engineering Express. 3. PMID 29250434 DOI: 10.1088/2057-1976/Aa6Ab6  0.321
2017 Yu EY, Chandrasekharan P, Berzon R, Tay ZW, Zhou XY, Khandhar AP, Ferguson RM, Kemp SJ, Zheng B, Goodwill PW, Wendland MF, Krishnan KM, Behr S, Carter J, Conolly SM. Magnetic Particle Imaging for Highly Sensitive, Quantitative and Safe in vivo Gut Bleed Detection in a Murine Model. Acs Nano. PMID 29165995 DOI: 10.1021/Acsnano.7B04844  0.4
2017 Zheng B, Yu E, Orendorff R, Lu K, Konkle JJ, Tay ZW, Hensley D, Zhou XY, Chandrasekharan P, Saritas EU, Goodwill PW, Hazle JD, Conolly SM. Seeing SPIOs Directly In Vivo with Magnetic Particle Imaging. Molecular Imaging and Biology : Mib : the Official Publication of the Academy of Molecular Imaging. PMID 28396973 DOI: 10.1007/S11307-017-1081-Y  0.472
2017 Knopp T, Conolly SM, Buzug TM. Recent progress in magnetic particle imaging: from hardware to preclinical applications. Physics in Medicine and Biology. 62: E4-E7. PMID 28378712 DOI: 10.1088/1361-6560/aa62c7  0.376
2017 Orendorff R, Peck AJ, Zheng B, Shirazi SN, Matthew Ferguson R, Khandhar AP, Kemp SJ, Goodwill P, Krishnan KM, Brooks GA, Kaufer D, Conolly S. First in vivo traumatic brain injury imaging via magnetic particle imaging. Physics in Medicine and Biology. 62: 3501-3509. PMID 28378708 DOI: 10.1088/1361-6560/Aa52Ad  0.427
2017 Zhou XY, Jeffris K, Yu E, Zheng B, Goodwill P, Nahid P, Conolly S. First in vivo magnetic particle imaging of lung perfusion in rats. Physics in Medicine and Biology. PMID 28218614 DOI: 10.1088/1361-6560/Aa616C  0.411
2017 Yu EY, Bishop M, Zheng B, Ferguson RM, Khandhar AP, Kemp SJ, Krishnan KM, Goodwill PW, Conolly SM. Magnetic Particle Imaging: A Novel in vivo Imaging Platform for Cancer Detection. Nano Letters. PMID 28206771 DOI: 10.1021/Acs.Nanolett.6B04865  0.369
2017 Keselman P, Yu E, Zhou X, Goodwill P, Chandrasekharan P, Ferguson RM, Khandhar A, Kemp S, Krishnan K, Zheng B, Conolly S. Tracking short-term biodistribution and long-term clearance of SPIO tracers in magnetic particle imaging. Physics in Medicine and Biology. PMID 28177301 DOI: 10.1088/1361-6560/Aa5F48  0.328
2017 Khandhar AP, Keselman P, Kemp SJ, Ferguson RM, Goodwill PW, Conolly SM, Krishnan KM. Evaluation of PEG-coated iron oxide nanoparticles as blood pool tracers for preclinical magnetic particle imaging. Nanoscale. PMID 28059427 DOI: 10.1039/C6Nr08468K  0.375
2017 Hensley D, Tay ZW, Dhavalikar R, Goodwill P, Zheng B, Rinaldi C, Conolly S. A theranostic platform for localized magnetic fluid hyperthermia and magnetic particle imaging Proceedings of Spie. 10066: 1006603. DOI: 10.1117/12.2256350  0.555
2016 Hensley DW, Tay ZW, Dhavalikar R, Zheng B, Goodwill P, Rinaldi C, Conolly S. Combining magnetic particle imaging and magnetic fluid hyperthermia in a theranostic platform. Physics in Medicine and Biology. PMID 28032621 DOI: 10.1088/1361-6560/Aa5601  0.483
2016 Tay ZW, Goodwill PW, Hensley DW, Taylor LA, Zheng B, Conolly SM. A High-Throughput, Arbitrary-Waveform, MPI Spectrometer and Relaxometer for Comprehensive Magnetic Particle Optimization and Characterization. Scientific Reports. 6: 34180. PMID 27686629 DOI: 10.1038/Srep34180  0.364
2016 Bauer LM, Hensley DW, Zheng B, Tay ZW, Goodwill PW, Griswold MA, Conolly SM. Eddy current-shielded x-space relaxometer for sensitive magnetic nanoparticle characterization. The Review of Scientific Instruments. 87: 055109. PMID 27250472 DOI: 10.1063/1.4950779  0.321
2016 Croft LR, Goodwill PW, Konkle JJ, Arami H, Price DA, Li AX, Saritas EU, Conolly SM. Low drive field amplitude for improved image resolution in magnetic particle imaging. Medical Physics. 43: 424. PMID 26745935 DOI: 10.1118/1.4938097  0.378
2016 Dhavalikar R, Hensley D, Maldonado-Camargo L, Croft LR, Ceron S, Goodwill PW, Conolly SM, Rinaldi C. Finite magnetic relaxation in x-space magnetic particle imaging: Comparison of measurements and ferrohydrodynamic models Journal of Physics D: Applied Physics. 49. DOI: 10.1088/0022-3727/49/30/305002  0.38
2015 Konkle JJ, Goodwill PW, Hensley DW, Orendorff RD, Lustig M, Conolly SM. A Convex Formulation for Magnetic Particle Imaging X-Space Reconstruction. Plos One. 10: e0140137. PMID 26495839 DOI: 10.1371/Journal.Pone.0140137  0.379
2015 Zheng B, Vazin T, Goodwill PW, Conway A, Verma A, Ulku Saritas E, Schaffer D, Conolly SM. Magnetic Particle Imaging tracks the long-term fate of in vivo neural cell implants with high image contrast. Scientific Reports. 5: 14055. PMID 26358296 DOI: 10.1038/Srep14055  0.39
2015 Saritas EU, Goodwill PW, Conolly SM. Effects of pulse duration on magnetostimulation thresholds. Medical Physics. 42: 3005-12. PMID 26127053 DOI: 10.1118/1.4921209  0.513
2015 Arami H, Khandhar AP, Tomitaka A, Yu E, Goodwill PW, Conolly SM, Krishnan KM. In vivo multimodal magnetic particle imaging (MPI) with tailored magneto/optical contrast agents. Biomaterials. 52: 251-61. PMID 25818431 DOI: 10.1016/J.Biomaterials.2015.02.040  0.331
2015 Ferguson RM, Khandhar AP, Kemp SJ, Arami H, Saritas EU, Croft LR, Konkle J, Goodwill PW, Halkola A, Rahmer J, Borgert J, Conolly SM, Krishnan KM. Magnetic particle imaging with tailored iron oxide nanoparticle tracers. Ieee Transactions On Medical Imaging. 34: 1077-84. PMID 25438306 DOI: 10.1109/Tmi.2014.2375065  0.45
2015 Lee G, Jordan C, Tiet P, Ruiz C, McCormick J, Phuong K, Hargreaves B, Conolly S. Improved frequency selective fat suppression in the posterior neck with tissue susceptibility matched pyrolytic graphite foam. Journal of Magnetic Resonance Imaging : Jmri. 41: 684-93. PMID 24677296 DOI: 10.1002/Jmri.24581  0.362
2015 Goodwill P, Ferguson M, Yu E, Zheng B, Lu K, Khandhar A, Kemp S, Krishnan K, Conolly S. E-139 in vivoperfusion imaging using magnetic particle imaging Journal of Neurointerventional Surgery. 7: A105.1-A105. DOI: 10.1136/Neurintsurg-2015-011917.213  0.468
2013 Konkle JJ, Goodwill PW, Saritas EU, Zheng B, Lu K, Conolly SM. Twenty-fold acceleration of 3D projection reconstruction MPI. Biomedizinische Technik. Biomedical Engineering. 58: 565-76. PMID 23940058 DOI: 10.1515/Bmt-2012-0062  0.394
2013 Saritas EU, Goodwill PW, Zhang GZ, Conolly SM. Magnetostimulation limits in magnetic particle imaging. Ieee Transactions On Medical Imaging. 32: 1600-10. PMID 23649181 DOI: 10.1109/Tmi.2013.2260764  0.361
2013 Lu K, Goodwill PW, Saritas EU, Zheng B, Conolly SM. Linearity and shift invariance for quantitative magnetic particle imaging. Ieee Transactions On Medical Imaging. 32: 1565-75. PMID 23568496 DOI: 10.1109/Tmi.2013.2257177  0.408
2013 Saritas EU, Goodwill PW, Croft LR, Konkle JJ, Lu K, Zheng B, Conolly SM. Magnetic particle imaging (MPI) for NMR and MRI researchers. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 229: 116-26. PMID 23305842 DOI: 10.1016/J.Jmr.2012.11.029  0.46
2013 Lu K, Zheng B, Konkle J, Saritas E, Goodwill P, Conolly S. Towards multidimensional x-space magnetic particle imaging for improved resolution 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528389  0.412
2013 Goodwill PW, Croft LR, Konkle JJ, Lu K, Saritas EU, Zheng B, Conolly SM. A 7 T/M 3D X-space MPI mouse and rat scanner 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528387  0.365
2013 Croft LR, Goodwill PW, Price DA, Saritas EU, Li AX, Conolly SM. Effects of scanning rate on relaxation-induced blurring in magnetic particle image 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528382  0.369
2013 Zheng B, Vazin T, Yang W, Goodwill PW, Saritas EU, Croft LR, Schaffer DV, Conolly SM. Quantitative stem cell imaging with magnetic particle imaging 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528323  0.392
2013 Konkle JJ, Goodwill PW, Saritas EU, Conolly SM. Twenty-fold acquisition time improvement in 3D projection reconstruction MPI 2013 International Workshop On Magnetic Particle Imaging, Iwmpi 2013. DOI: 10.1109/IWMPI.2013.6528322  0.396
2012 Croft LR, Goodwill PW, Conolly SM. Relaxation in x-space magnetic particle imaging. Ieee Transactions On Medical Imaging. 31: 2335-42. PMID 22968211 DOI: 10.1109/Tmi.2012.2217979  0.348
2012 Lillaney P, Shin M, Conolly SM, Fahrig R. Magnetostatic focal spot correction for x-ray tubes operating in strong magnetic fields using iterative optimization. Medical Physics. 39: 5567-83. PMID 22957623 DOI: 10.1118/1.4742060  0.31
2012 Goodwill PW, Konkle JJ, Zheng B, Saritas EU, Conolly SM. Projection x-space magnetic particle imaging. Ieee Transactions On Medical Imaging. 31: 1076-85. PMID 22552332 DOI: 10.1109/Tmi.2012.2185247  0.365
2012 Goodwill PW, Lu K, Zheng B, Conolly SM. An x-space magnetic particle imaging scanner. The Review of Scientific Instruments. 83: 033708. PMID 22462930 DOI: 10.1063/1.3694534  0.413
2012 Stang PP, Conolly SM, Santos JM, Pauly JM, Scott GC. Medusa: a scalable MR console using USB. Ieee Transactions On Medical Imaging. 31: 370-9. PMID 21954200 DOI: 10.1109/TMI.2011.2169681  0.568
2011 Ahn KH, Scott G, Stang P, Conolly S, Hristov D. Multiparametric imaging of tumor oxygenation, redox status, and anatomical structure using Overhauser-enhanced MRI-prepolarized MRI system. Magnetic Resonance in Medicine. 65: 1416-22. PMID 21500268 DOI: 10.1002/Mrm.22732  0.414
2011 Goodwill PW, Conolly SM. Multidimensional x-space magnetic particle imaging. Ieee Transactions On Medical Imaging. 30: 1581-90. PMID 21402508 DOI: 10.1109/Tmi.2011.2125982  0.433
2011 Goodwill PW, Conolly SM. Experimental demonstration of x-space magnetic particle imaging Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7965. DOI: 10.1117/12.878659  0.377
2011 Tamrazian A, Goodwill P, Croft LR, Pidaparthi R, Ferguson RM, Krishnan K, Conolly S. X-space MPI relaxometry: Methods and initial data Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7965. DOI: 10.1117/12.878608  0.454
2011 Lu K, Goodwill P, Zheng B, Conolly S. The impact of filtering direct-feedthrough on the x-space theory of magnetic particle imaging Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7965. DOI: 10.1117/12.878446  0.44
2011 Zheng B, Goodwill P, Conolly S. Transmit filter design methods for magnetic particle imaging Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7965. DOI: 10.1117/12.878443  0.4
2011 Konkle J, Goodwill P, Conolly S. Development of a field free line magnet for projection MPI Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7965. DOI: 10.1117/12.878435  0.591
2011 Croft LR, Goodwill P, Tamrazian A, Krishnan K, Conolly S. The x-space formulation of magnetic particle imaging including nonnegligible relaxation effects Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7965. DOI: 10.1117/12.878418  0.56
2011 Goodwill PW, Tamrazian A, Croft LR, Lu CD, Johnson EM, Pidaparthi R, Ferguson RM, Khandhar AP, Krishnan KM, Conolly SM. Ferrohydrodynamic relaxometry for magnetic particle imaging Applied Physics Letters. 98. DOI: 10.1063/1.3604009  0.385
2010 Lee GC, Goodwill PW, Phuong K, Inglis BA, Scott GC, Hargreaves BA, Li L, Chen AC, Shah RN, Conolly SM. Pyrolytic graphite foam: a passive magnetic susceptibility matching material. Journal of Magnetic Resonance Imaging : Jmri. 32: 684-91. PMID 20815067 DOI: 10.1002/Jmri.22270  0.426
2010 Goodwill PW, Conolly SM. The X-space formulation of the magnetic particle imaging process: 1-D signal, resolution, bandwidth, SNR, SAR, and magnetostimulation. Ieee Transactions On Medical Imaging. 29: 1851-9. PMID 20529726 DOI: 10.1109/Tmi.2010.2052284  0.471
2009 Goodwill PW, Scott GC, Stang PP, Conolly SM. Narrowband magnetic particle imaging. Ieee Transactions On Medical Imaging. 28: 1231-7. PMID 19211340 DOI: 10.1109/Tmi.2009.2013849  0.472
2008 Null B, Liu CW, Hedehus M, Conolly S, Davis RW. High-resolution, in vivo magnetic resonance imaging of Drosophila at 18.8 Tesla. Plos One. 3: e2817. PMID 18665264 DOI: 10.1371/Journal.Pone.0002817  0.521
2008 Matter NI, Chronik B, Pauly JM, Macovski A, Conolly SM, Scott GC. Noise performance of a precision pulsed electromagnet power supply for magnetic resonance imaging. Ieee Transactions On Medical Imaging. 27: 75-86. PMID 18270064 DOI: 10.1109/Tmi.2007.903253  0.827
2007 Larson PE, Conolly SM, Pauly JM, Nishimura DG. Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging. Magnetic Resonance in Medicine. 58: 952-61. PMID 17969119 DOI: 10.1002/Mrm.21341  0.725
2007 Wen Z, Fahrig R, Conolly S, Pelc NJ. Investigation of electron trajectories of an x-ray tube in magnetic fields of MR scanners. Medical Physics. 34: 2048-58. PMID 17654908 DOI: 10.1118/1.2733798  0.463
2006 Matter NI, Scott GC, Venook RD, Ungersma SE, Grafendorfer T, Macovski A, Conolly SM. Three-dimensional prepolarized magnetic resonance imaging using rapid acquisition with relaxation enhancement. Magnetic Resonance in Medicine. 56: 1085-95. PMID 17029228 DOI: 10.1002/Mrm.21065  0.779
2006 Park JB, Hu BS, Conolly SM, Nayak KS, Nishimura DG. Rapid cardiac-output measurement with ungated spiral phase contrast. Magnetic Resonance in Medicine. 56: 432-8. PMID 16802317 DOI: 10.1002/Mrm.20970  0.5
2006 Venook RD, Matter NI, Ramachandran M, Ungersma SE, Gold GE, Giori NJ, Macovski A, Scott GC, Conolly SM. Prepolarized magnetic resonance imaging around metal orthopedic implants. Magnetic Resonance in Medicine. 56: 177-86. PMID 16724303 DOI: 10.1002/Mrm.20927  0.762
2006 Ungersma SE, Matter NI, Hardy JW, Venook RD, Macovski A, Conolly SM, Scott GC. Magnetic resonance imaging with T1 dispersion contrast. Magnetic Resonance in Medicine. 55: 1362-71. PMID 16673360 DOI: 10.1002/Mrm.20910  0.759
2006 Lee J, Santos JM, Conolly SM, Miller KL, Hargreaves BA, Pauly JM. Respiration-induced B0 field fluctuation compensation in balanced SSFP: real-time approach for transition-band SSFP fMRI. Magnetic Resonance in Medicine. 55: 1197-201. PMID 16598728 DOI: 10.1002/Mrm.20879  0.506
2006 Matter NI, Scott GC, Grafendorfer T, Macovski A, Conolly SM. Rapid polarizing field cycling in magnetic resonance imaging. Ieee Transactions On Medical Imaging. 25: 84-93. PMID 16398417 DOI: 10.1109/Tmi.2005.861014  0.836
2005 Venook RD, Hargreaves BA, Gold GE, Conolly SM, Scott GC. Automatic tuning of flexible interventional RF receiver coils. Magnetic Resonance in Medicine. 54: 983-93. PMID 16155871 DOI: 10.1002/Mrm.20616  0.768
2005 Cunningham CH, Arai T, Yang PC, McConnell MV, Pauly JM, Conolly SM. Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles. Magnetic Resonance in Medicine. 53: 999-1005. PMID 15844142 DOI: 10.1002/Mrm.20477  0.587
2005 Vidarsson L, Conolly SM, Lim KO, Gold GE, Pauly JM. Echo time optimization for linear combination myelin imaging. Magnetic Resonance in Medicine. 53: 398-407. PMID 15678534 DOI: 10.1002/Mrm.20360  0.527
2005 Zhang B, Gazdzinski C, Chronik BA, Xu H, Conolly SM, Rutt BK. Simple design guidelines for short MRI systems Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering. 25: 53-59. DOI: 10.1002/cmr.b.20033  0.339
2004 Ungersma SE, Xu H, Chronik BA, Scott GC, Macovski A, Conolly SM. Shim design using a linear programming algorithm. Magnetic Resonance in Medicine. 52: 619-27. PMID 15334583 DOI: 10.1002/Mrm.20176  0.794
2004 Hargreaves BA, Cunningham CH, Nishimura DG, Conolly SM. Variable-rate selective excitation for rapid MRI sequences. Magnetic Resonance in Medicine. 52: 590-7. PMID 15334579 DOI: 10.1002/Mrm.20168  0.656
2004 Hargreaves BA, Nishimura DG, Conolly SM. Time-optimal multidimensional gradient waveform design for rapid imaging. Magnetic Resonance in Medicine. 51: 81-92. PMID 14705048 DOI: 10.1002/Mrm.10666  0.583
2002 Overall WR, Conolly SM, Nishimura DG, Hu BS. Oscillating dual-equilibrium steady-state angiography. Magnetic Resonance in Medicine. 47: 513-22. PMID 11870838 DOI: 10.1002/Mrm.10070  0.532
2002 Shao W, Wang G, Fuzesy R, Hughes EW, Chronik BA, Scott GC, Conolly SM, MacOvski A. Low readout field magnetic resonance imaging of hyperpolarized xenon and water in a single system Applied Physics Letters. 80: 2032-2034. DOI: 10.1063/1.1459759  0.703
2000 Xu H, Conolly SM, Scott GC, Macovski A. Homogeneous magnet design using linear programming Ieee Transactions On Magnetics. 36: 476-483. DOI: 10.1109/20.825817  0.576
1999 Hargreaves BA, Gold GE, Lang PK, Conolly SM, Pauly JM, Bergman G, Vandevenne J, Nishimura DG. MR imaging of articular cartilage using driven equilibrium. Magnetic Resonance in Medicine. 42: 695-703. PMID 10502758 DOI: 10.1002/(Sici)1522-2594(199910)42:4<695::Aid-Mrm11>3.0.Co;2-Z  0.73
1999 Morgan PN, Conolly SM, Macovski A. Resistive homogeneous MRI magnet design by matrix subset selection. Magnetic Resonance in Medicine. 41: 1221-9. PMID 10371455 DOI: 10.1002/(Sici)1522-2594(199906)41:6<1221::Aid-Mrm19>3.0.Co;2-E  0.675
1997 Mani S, Pauly J, Conolly S, Meyer C, Nishimura D. Background suppression with multiple inversion recovery nulling: applications to projective angiography. Magnetic Resonance in Medicine. 37: 898-905. PMID 9178242 DOI: 10.1002/Mrm.1910370615  0.762
1996 Morgan P, Conolly S, Scott G, Macovski A. A readout magnet for prepolarized MRI. Magnetic Resonance in Medicine. 36: 527-36. PMID 8892203 DOI: 10.1002/Mrm.1910360405  0.71
1994 Hu BS, Conolly SM. 5250898 Method and means for magnetic resonance imaging and spectroscopy using pulsed saturation transfer contrast Magnetic Resonance Imaging. 12: XXI. DOI: 10.1016/0730-725X(94)92284-5  0.465
1993 Macovski A, Conolly S. Novel approaches to low-cost MRI. Magnetic Resonance in Medicine. 30: 221-30. PMID 8366803 DOI: 10.1002/Mrm.1910300211  0.705
1993 Conolly SM, Pauly J. 5189371 Method and means for magnetic resonance imaging and spectroscopy using two-dimensional selective adiabatic PI pulses Magnetic Resonance Imaging. 11: XLIV. DOI: 10.1016/0730-725X(93)90326-9  0.659
1992 Conolly S, Pauly J, Nishimura D, Macovski A. Two-dimensional selective adiabatic pulses. Magnetic Resonance in Medicine. 24: 302-13. PMID 1569869 DOI: 10.1002/mrm.1910240211  0.774
1992 Hu BS, Conolly SM, Wright GA, Nishimura DG, Macovski A. Pulsed saturation transfer contrast. Magnetic Resonance in Medicine. 26: 231-40. PMID 1325023 DOI: 10.1002/Mrm.1910260205  0.751
1991 Conolly S, Glover G, Nishimura D, Macovski A. A reduced power selective adiabatic spin-echo pulse sequence. Magnetic Resonance in Medicine. 18: 28-38. PMID 2062239 DOI: 10.1002/Mrm.1910180105  0.736
1990 Conolly SM. 4868501 Method and means for magnetic resonance spin-echo imaging using an adiabatic three pi pulse sequence Magnetic Resonance Imaging. 8: II-III. DOI: 10.1016/0730-725X(90)90158-X  0.427
1989 Conolly S, Nishimura D, Macovski A. Sweep-diagram analysis of selective adiabatic pulses Journal of Magnetic Resonance (1969). 83: 549-564. DOI: 10.1016/0022-2364(89)90348-X  0.703
1989 Conolly S, Nishimura D, Macovski A. A selective adiabatic spin-echo pulse Journal of Magnetic Resonance (1969). 83: 324-334. DOI: 10.1016/0022-2364(89)90194-7  0.705
1988 Conolly S, Nishimura D, Macovski A, Glover G. Variable-rate selective excitation Journal of Magnetic Resonance (1969). 78: 440-458. DOI: 10.1016/0022-2364(88)90131-X  0.677
1987 Nishimura DG, Macovski A, Pauly JM, Conolly SM. MR angiography by selective inversion recovery. Magnetic Resonance in Medicine. 4: 193-202. PMID 3561250 DOI: 10.1002/Mrm.1910040214  0.718
1986 Conolly S, Nishimura D, Macovski A. Optimal control solutions to the magnetic resonance selective excitation problem. Ieee Transactions On Medical Imaging. 5: 106-15. PMID 18243994 DOI: 10.1109/Tmi.1986.4307754  0.749
Show low-probability matches.