Christopher L. Brace, PhD - Publications

Affiliations: 
2009- Biomedical Engineering University of Wisconsin, Madison, Madison, WI 
Area:
Image-guided medical therapies
Website:
http://directory.engr.wisc.edu/bme/faculty/brace_chris

103 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2022 Treb K, Ji X, Feng M, Zhang R, Periyasamy S, Laeseke PF, Dingle AM, Brace CL, Li K. A C-arm photon counting CT prototype with volumetric coverage using multi-sweep step-and-shoot acquisitions. Physics in Medicine and Biology. PMID 36162399 DOI: 10.1088/1361-6560/ac950d  0.547
2020 Ziemlewicz TJ, Hinshaw JL, Lubner MG, Knott EA, Willey BJ, Lee FT, Brace CL. Radiofrequency and microwave ablation in a porcine liver model: non-contrast CT and ultrasound radiologic-pathologic correlation. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 37: 799-807. PMID 32620055 DOI: 10.1080/02656736.2020.1784471  0.38
2020 Kok HP, Cressman ENK, Ceelen W, Brace CL, Ivkov R, Grüll H, Ter Haar G, Wust P, Crezee J. Heating technology for malignant tumors: a review. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 37: 711-741. PMID 32579419 DOI: 10.1080/02656736.2020.1779357  0.334
2020 Hui TCH, Brace CL, Hinshaw JL, Quek LHH, Huang IKH, Kwan J, Lim GHT, Lee FT, Pua U. Microwave ablation of the liver in a live porcine model: the impact of power, time and total energy on ablation zone size and shape. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 37: 668-676. PMID 32552123 DOI: 10.1080/02656736.2020.1774083  0.377
2019 Etoz S, Brace CL. Computed Tomography-Based Modeling of Water Vapor-Induced Changes in Permittivity During Microwave Ablation. Ieee Transactions On Bio-Medical Engineering. PMID 31880538 DOI: 10.1109/Tbme.2019.2962363  0.314
2019 Liu D, Brace CL. Evaluation of Tissue Deformation during Radiofrequency and Microwave Ablation Procedures: Influence of Output Energy Delivery. Medical Physics. PMID 31260115 DOI: 10.1002/Mp.13688  0.33
2019 Meram E, Harari C, Shaughnessy G, Wagner M, Brace CL, Mistretta CA, Speidel MA, Laeseke PF. Quantitative 4D-Digital Subtraction Angiography to Assess Changes in Hepatic Arterial Flow during Transarterial Embolization: A Feasibility Study in a Swine Model. Journal of Vascular and Interventional Radiology : Jvir. PMID 31160194 DOI: 10.1016/J.Jvir.2019.01.018  0.567
2019 Swietlik JF, Longo KC, Knott EA, Hinshaw JL, Brace CL, Alexander M, Lubner MG, Wells SA, Lee FT, Ziemlewicz TJ. Percutaneous Microwave Tumor Ablation Is Safe in Patients with Cardiovascular Implantable Electronic Devices: A Single-Institutional Retrospective Review. Journal of Vascular and Interventional Radiology : Jvir. 30: 396-400. PMID 30819482 DOI: 10.1016/J.Jvir.2018.12.001  0.319
2019 Lee KS, Sin JM, Patil PP, Hanna AS, Greenberg JA, Zea RD, Brace CL. Ultrasound-Guided Microwave Ablation for the Management of Inguinal Neuralgia: A Preliminary Study with 1-Year Follow-up. Journal of Vascular and Interventional Radiology : Jvir. 30: 242-248. PMID 30717957 DOI: 10.1016/J.Jvir.2018.10.031  0.326
2019 Ozturk M, Moore K, Schafer S, Brace C, Hinshaw J, Lee F, Wagner M, Speidel M, Laeseke P. 04:03 PM Abstract No. 293 Cone-beam CT with augmented fluoroscopy: a novel approach for navigating airways and guiding transbronchial interventions Journal of Vascular and Interventional Radiology. 30: S131. DOI: 10.1016/J.Jvir.2018.12.358  0.561
2018 Meram E, Longhurst C, Brace CL, Laeseke PF. Comparison of Conventional and Cone-Beam CT for Monitoring and Assessing Pulmonary Microwave Ablation in a Porcine Model. Journal of Vascular and Interventional Radiology : Jvir. PMID 30217749 DOI: 10.1016/J.Jvir.2018.04.035  0.594
2018 Knavel EM, Green CM, Gendron-Fitzpatrick A, Brace CL, Laeseke PF. Combination Therapies: Quantifying the Effects of Transarterial Embolization on Microwave Ablation Zones. Journal of Vascular and Interventional Radiology : Jvir. PMID 29754849 DOI: 10.1016/J.Jvir.2018.01.785  0.644
2018 Niemeier RC, Etoz S, Gil DA, Skala MC, Brace CL, Rogers JD. Quantifying optical properties with visible and near-infrared optical coherence tomography to visualize esophageal microwave ablation zones. Biomedical Optics Express. 9: 1648-1663. PMID 29675308 DOI: 10.1364/Boe.9.001648  0.325
2018 Smolock AR, Cristescu MM, Hinshaw A, Woo KM, Wells SA, Ziemlewicz TJ, Lubner MG, Dalvie PS, Louis Hinshaw J, Brace CL, Ozkan OS, Lee FT, Laeseke P. Combination transarterial chemoembolization and microwave ablation improves local tumor control for 3- to 5-cm hepatocellular carcinoma when compared with transarterial chemoembolization alone. Abdominal Radiology (New York). PMID 29450606 DOI: 10.1007/S00261-018-1464-9  0.608
2018 Meram E, Longhurst C, Brace C, Laeseke P. 3:50 PM Abstract No. 48 Comparison of conventional and cone-beam computed tomograpy for guiding and assessing pulmonary microwave ablation Journal of Vascular and Interventional Radiology. 29: S24-S25. DOI: 10.1016/J.Jvir.2018.01.057  0.589
2017 Carberry GA, Nocerino E, Cristescu MM, Smolock AR, Lee FT, Brace CL. Microwave Ablation of the Lung in a Porcine Model: Vessel Diameter Predicts Pulmonary Artery Occlusion. Cardiovascular and Interventional Radiology. PMID 28497186 DOI: 10.1007/S00270-017-1689-Y  0.308
2017 Chiang J, Nickel K, Kimple RJ, Brace CL. Potential Mechanisms of Vascular Thrombosis after Microwave Ablation in an in Vivo Liver. Journal of Vascular and Interventional Radiology : Jvir. PMID 28456355 DOI: 10.1016/J.Jvir.2017.03.034  0.558
2017 Samimi K, White JK, Brace CL, Varghese T. Monitoring Microwave Ablation of Ex Vivo Bovine Liver Using Ultrasonic Attenuation Imaging. Ultrasound in Medicine & Biology. PMID 28454843 DOI: 10.1016/J.Ultrasmedbio.2017.03.010  0.367
2017 Wu PH, Borden Z, Brace CL. Ablation Zone Visualization Enhancement by Periodic Contrast-Enhancement Computed Tomography During Microwave Ablation. Medical Physics. PMID 28391605 DOI: 10.1002/Mp.12266  0.326
2017 Carberry GA, Smolock AR, Cristescu M, Wells SA, Ziemlewicz TJ, Lubner MG, Hinshaw JL, Brace CL, Lee FT. Safety and Efficacy of Percutaneous Microwave Hepatic Ablation Near the Heart. Journal of Vascular and Interventional Radiology : Jvir. PMID 28190707 DOI: 10.1016/J.Jvir.2016.12.1216  0.302
2017 Liu D, Brace C. Numerical simulation of microwave ablation incorporating tissue contraction based on thermal dose. Physics in Medicine and Biology. PMID 28151729 DOI: 10.1088/1361-6560/Aa5De4  0.356
2017 Klapperich ME, Abel EJ, Ziemlewicz TJ, Best S, Lubner MG, Nakada SY, Hinshaw JL, Brace CL, Lee FT, Wells SA. Effect of Tumor Complexity and Technique on Efficacy and Complications after Percutaneous Microwave Ablation of Stage T1a Renal Cell Carcinoma: A Single-Center, Retrospective Study. Radiology. 160592. PMID 28076721 DOI: 10.1148/Radiol.2016160592  0.343
2017 Etoz S, Brace CL. Analysis of microwave ablation antenna optimization techniques International Journal of Rf and Microwave Computer-Aided Engineering. 28: e21224. DOI: 10.1002/Mmce.21224  0.351
2016 Moon TJ, Brace CL. Design of a dual slot antenna for small animal microwave ablation studies. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2016: 348-351. PMID 28324928 DOI: 10.1109/EMBC.2016.7590711  0.321
2016 Moon TJ, Brace CL, Moon TJ, Brace CL, Brace CL, Moon TJ. Design of a dual slot antenna for small animal microwave ablation studies. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2016: 348-351. PMID 28226509 DOI: 10.1109/EMBC.2016.7590711  0.321
2016 Carberry GA, Nocerino E, Mason PJ, Schwahn DJ, Hetzel S, Turnquist AM, Lee FT, Brace CL. Pulmonary Microwave Ablation Near the Heart: Antenna Positioning Can Mitigate Cardiac Complications in a Porcine Model. Radiology. 160831. PMID 27732159 DOI: 10.1148/Radiol.2016160831  0.353
2016 Ryan TP, Brace CL. Interstitial microwave treatment for cancer: historical basis and current techniques in antenna design and performance. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 1-31. PMID 27492859 DOI: 10.1080/02656736.2016.1214884  0.414
2016 Wu PH, Brace CL. Analysis of iodinated contrast delivered during thermal ablation: is material trapped in the ablation zone? Physics in Medicine and Biology. 61: 6041-6054. PMID 27452478 DOI: 10.1088/0031-9155/61/16/6041  0.375
2016 Meloni MF, Chiang J, Laeseke PF, Dietrich CF, Sannino A, Solbiati M, Nocerino E, Brace CL, Lee FT. MICROWAVE ABLATION IN PRIMARY AND SECONDARY LIVER TUMORS: TECHNICAL AND CLINICAL APPROACHES. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 1-33. PMID 27416729 DOI: 10.1080/02656736.2016.1209694  0.702
2016 Chiang J, Cristescu M, Lee MH, Moreland A, Hinshaw JL, Lee FT, Brace CL. Effects of Microwave Ablation on Arterial and Venous Vasculature after Treatment of Hepatocellular Carcinoma. Radiology. 152508. PMID 27257951 DOI: 10.1148/Radiol.2016152508  0.567
2016 Wells SA, Wheeler KM, Mithqal A, Patel MS, Brace CL, Schenkman NS. Percutaneous microwave ablation of T1a and T1b renal cell carcinoma: short-term efficacy and complications with emphasis on tumor complexity and single session treatment. Abdominal Radiology (New York). PMID 27167230 DOI: 10.1007/S00261-016-0776-X  0.311
2016 Ziemlewicz TJ, Wells SA, Lubner MG, Brace CL, Lee FT, Hinshaw JL. Hepatic Tumor Ablation. The Surgical Clinics of North America. 96: 315-39. PMID 27017867 DOI: 10.1016/J.Suc.2015.12.006  0.346
2016 Potretzke TA, Ziemlewicz TJ, Louis Hinshaw J, Lubner MG, Wells SA, Brace CL, Agarwal P, Lee FT. Microwave versus Radiofrequency Ablation Treatment for Hepatocellular Carcinoma: A Comparison of Efficacy at a Single Center. Journal of Vascular and Interventional Radiology : Jvir. PMID 27017124 DOI: 10.1016/J.Jvir.2016.01.136  0.32
2016 Francica G, Meloni MF, de Sio I, Smolock AR, Brace CL, Iadevaia MD, Santambrogio R, Sironi S, Scaglione M, Lee FT. Radiofrequency and microwave ablation of subcapsular hepatocellular carcinoma accessed by direct puncture: Safety and efficacy. European Journal of Radiology. 85: 739-43. PMID 26971417 DOI: 10.1016/J.Ejrad.2016.01.020  0.33
2016 Smolock AR, Cristescu MM, Potretzke TA, Ziemlewicz TJ, Lubner MG, Hinshaw JL, Brace CL, Lee FT. Microwave Ablation for the Treatment of Hepatic Adenomas. Journal of Vascular and Interventional Radiology : Jvir. 27: 244-9. PMID 26830938 DOI: 10.1016/J.Jvir.2015.09.021  0.337
2016 Carberry G, Smolock A, Cristescu M, Ziemlewicz T, Wells S, Hinshaw J, Lubner M, Brace C, Lee F. Percutaneous microwave ablation of liver tumors near the heart: safety and efficacy Journal of Vascular and Interventional Radiology. 27: S80. DOI: 10.1016/J.Jvir.2015.12.214  0.331
2015 Wells SA, Hinshaw JL, Lubner MG, Ziemlewicz TJ, Brace CL, Lee FT. Liver Ablation: Best Practice. Radiologic Clinics of North America. 53: 933-71. PMID 26321447 DOI: 10.1016/J.Rcl.2015.05.012  0.368
2015 Harari CM, Magagna M, Bedoya M, Lee FT, Lubner MG, Hinshaw JL, Ziemlewicz T, Brace CL. Microwave Ablation: Comparison of Simultaneous and Sequential Activation of Multiple Antennas in Liver Model Systems. Radiology. 142151. PMID 26133361 DOI: 10.1148/radiol.2015142151  0.321
2015 Johnson A, Brace C. Heat transfer within hydrodissection fluids: An analysis of thermal conduction and convection using liquid and gel materials. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 1-9. PMID 25960147 DOI: 10.3109/02656736.2015.1037799  0.342
2015 Smolock AR, Lubner MG, Ziemlewicz TJ, Hinshaw JL, Kitchin DR, Brace CL, Lee FT. Microwave ablation of hepatic tumors abutting the diaphragm is safe and effective. Ajr. American Journal of Roentgenology. 204: 197-203. PMID 25539257 DOI: 10.2214/Ajr.14.12879  0.328
2015 Ziemlewicz TJ, Hinshaw JL, Lubner MG, Brace CL, Alexander ML, Agarwal P, Lee FT. Percutaneous microwave ablation of hepatocellular carcinoma with a gas-cooled system: initial clinical results with 107 tumors. Journal of Vascular and Interventional Radiology : Jvir. 26: 62-8. PMID 25446425 DOI: 10.1016/J.Jvir.2014.09.012  0.312
2015 Moreland AJ, Lubner MG, Ziemlewicz TJ, Kitchin DR, Hinshaw JL, Johnson AD, Lee FT, Brace CL. Evaluation of a thermoprotective gel for hydrodissection during percutaneous microwave ablation: in vivo results. Cardiovascular and Interventional Radiology. 38: 722-30. PMID 25394594 DOI: 10.1007/S00270-014-1008-9  0.343
2015 Chiang J, Birla S, Bedoya M, Jones D, Subbiah J, Brace CL. Modeling and validation of microwave ablations with internal vaporization. Ieee Transactions On Bio-Medical Engineering. 62: 657-63. PMID 25330481 DOI: 10.1109/Tbme.2014.2363173  0.579
2015 Chiang J, Martin J, Nickel K, Kimple R, Brace C. Potential mechanisms of the heat-sink effect during microwave ablation of an in-vivo porcine liver model Journal of Vascular and Interventional Radiology. 26: S117-S118. DOI: 10.1016/J.Jvir.2014.12.318  0.562
2014 Bedoya M, del Rio AM, Chiang J, Brace CL. Microwave ablation energy delivery: influence of power pulsing on ablation results in an ex vivo and in vivo liver model. Medical Physics. 41: 123301. PMID 25471983 DOI: 10.1118/1.4901312  0.558
2014 Ahmed M, Solbiati L, Brace CL, Breen DJ, Callstrom MR, Charboneau JW, Chen MH, Choi BI, de Baère T, Dodd GD, Dupuy DE, Gervais DA, Gianfelice D, Gillams AR, Lee FT, et al. Image-guided tumor ablation: standardization of terminology and reporting criteria--a 10-year update. Journal of Vascular and Interventional Radiology : Jvir. 25: 1691-705.e4. PMID 25442132 DOI: 10.1016/J.Jvir.2014.08.027  0.301
2014 Chiang J, Willey BJ, Del Rio AM, Hinshaw JL, Lee FT, Brace CL. Predictors of thrombosis in hepatic vasculature during microwave tumor ablation of an in vivo porcine model. Journal of Vascular and Interventional Radiology : Jvir. 25: 1965-1971.e2. PMID 25255704 DOI: 10.1016/J.Jvir.2014.07.022  0.579
2014 Hinshaw JL, Lubner MG, Ziemlewicz TJ, Lee FT, Brace CL. Percutaneous tumor ablation tools: microwave, radiofrequency, or cryoablation--what should you use and why? Radiographics : a Review Publication of the Radiological Society of North America, Inc. 34: 1344-62. PMID 25208284 DOI: 10.1148/Rg.345140054  0.364
2014 Lubner MG, Ziemlewicz TJ, Hinshaw JL, Lee FT, Sampson LA, Brace CL. Creation of short microwave ablation zones: in vivo characterization of single and paired modified triaxial antennas. Journal of Vascular and Interventional Radiology : Jvir. 25: 1633-40. PMID 25156644 DOI: 10.1016/J.Jvir.2014.06.032  0.4
2014 Ahmed M, Solbiati L, Brace CL, Breen DJ, Callstrom MR, Charboneau JW, Chen MH, Choi BI, de Baère T, Dodd GD, Dupuy DE, Gervais DA, Gianfelice D, Gillams AR, Lee FT, et al. Image-guided tumor ablation: standardization of terminology and reporting criteria--a 10-year update. Radiology. 273: 241-60. PMID 24927329 DOI: 10.1148/Radiol.14132958  0.3
2013 Johnson A, Sprangers A, Cassidy P, Heyrman S, Hinshaw JL, Lubner M, Puccinelli J, Brace C. Design and validation of a thermoreversible material for percutaneous tissue hydrodissection. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. 101: 1400-9. PMID 24591222 DOI: 10.1002/Jbm.B.32959  0.331
2013 Lubner MG, Brace CL, Ziemlewicz TJ, Hinshaw JL, Lee FT. Microwave ablation of hepatic malignancy. Seminars in Interventional Radiology. 30: 56-66. PMID 24436518 DOI: 10.1055/S-0033-1333654  0.388
2013 Knavel EM, Brace CL. Tumor ablation: common modalities and general practices. Techniques in Vascular and Interventional Radiology. 16: 192-200. PMID 24238374 DOI: 10.1053/J.Tvir.2013.08.002  0.342
2013 Chiang J, Wang P, Brace CL. Computational modelling of microwave tumour ablations. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 29: 308-17. PMID 23738698 DOI: 10.3109/02656736.2013.799295  0.56
2013 Chiang J, Hynes KA, Bedoya M, Brace CL. A dual-slot microwave antenna for more spherical ablation zones: ex vivo and in vivo validation. Radiology. 268: 382-9. PMID 23579048 DOI: 10.1148/Radiol.13122128  0.622
2013 Andreano A, Brace CL. A comparison of direct heating during radiofrequency and microwave ablation in ex vivo liver. Cardiovascular and Interventional Radiology. 36: 505-11. PMID 22572764 DOI: 10.1007/S00270-012-0405-1  0.379
2013 Brace CL, Ziemlewicz TJ, Schefelker R, Hinshaw JL, Lubner MG, Lee FT. Microwave tumor ablation: Cooperative academic-industry development of a high-power gas-cooled system with early clinical results Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8584. DOI: 10.1117/12.2004094  0.395
2012 Chiang J, Hynes K, Brace CL. Flow-dependent vascular heat transfer during microwave thermal ablation. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2012: 5582-5. PMID 23367194 DOI: 10.1109/EMBC.2012.6347259  0.512
2012 Dewall RJ, Varghese T, Brace CL. Visualizing ex vivo radiofrequency and microwave ablation zones using electrode vibration elastography. Medical Physics. 39: 6692-700. PMID 23127063 DOI: 10.1118/1.4758061  0.327
2012 Campbell C, Lubner MG, Hinshaw JL, Muñoz del Rio A, Brace CL. Contrast media-doped hydrodissection during thermal ablation: optimizing contrast media concentration for improved visibility on CT images. Ajr. American Journal of Roentgenology. 199: 677-82. PMID 22915411 DOI: 10.2214/Ajr.11.7999  0.302
2012 Knavel EM, Hinshaw JL, Lubner MG, Andreano A, Warner TF, Lee FT, Brace CL. High-powered gas-cooled microwave ablation: shaft cooling creates an effective stick function without altering the ablation zone. Ajr. American Journal of Roentgenology. 198: W260-5. PMID 22358023 DOI: 10.2214/Ajr.11.6503  0.37
2012 Lubner MG, Hinshaw JL, Andreano A, Sampson L, Lee FT, Brace CL. High-powered microwave ablation with a small-gauge, gas-cooled antenna: initial ex vivo and in vivo results. Journal of Vascular and Interventional Radiology : Jvir. 23: 405-11. PMID 22277272 DOI: 10.1016/J.Jvir.2011.11.003  0.329
2012 DeWall RJ, Varghese T, Brace CL. Quantifying local stiffness variations in radiofrequency ablations with dynamic indentation. Ieee Transactions On Bio-Medical Engineering. 59: 728-35. PMID 22167553 DOI: 10.1109/Tbme.2011.2178848  0.345
2012 Wang P, Brace CL. Tissue dielectric measurement using an interstitial dipole antenna. Ieee Transactions On Bio-Medical Engineering. 59: 115-21. PMID 21914566 DOI: 10.1109/Tbme.2011.2167622  0.417
2012 Chiang J, Hynes K, Brace C. Abstract No. 280: Cytotoxic heat transfer along vessels near microwave ablation zones: preliminary phantom studies Journal of Vascular and Interventional Radiology. 23: S114. DOI: 10.1016/J.Jvir.2011.12.334  0.529
2011 Brace C. Thermal tumor ablation in clinical use Ieee Pulse. 2: 28-38. PMID 25372967 DOI: 10.1109/Mpul.2011.942603  0.301
2011 Brace CL. Dual-slot antennas for microwave tissue heating: parametric design analysis and experimental validation. Medical Physics. 38: 4232-40. PMID 21859025 DOI: 10.1118/1.3601019  0.403
2011 Ji Z, Brace CL. Expanded modeling of temperature-dependent dielectric properties for microwave thermal ablation. Physics in Medicine and Biology. 56: 5249-64. PMID 21791728 DOI: 10.1088/0031-9155/56/16/011  0.373
2011 Brace CL, Hinshaw JL, Lubner MG. Thermal ablation for the treatment of abdominal tumors. Journal of Visualized Experiments : Jove. PMID 21445029 DOI: 10.3791/2596  0.448
2011 Sonntag PD, Hinshaw JL, Lubner MG, Brace CL, Lee FT. Thermal ablation of lung tumors. Surgical Oncology Clinics of North America. 20: 369-87, ix. PMID 21377589 DOI: 10.1016/J.Soc.2010.11.008  0.348
2011 Ahmed M, Brace CL, Lee FT, Goldberg SN. Principles of and advances in percutaneous ablation. Radiology. 258: 351-69. PMID 21273519 DOI: 10.1148/Radiol.10081634  0.364
2010 Brace CL. Microwave tissue ablation: biophysics, technology, and applications. Critical Reviews in Biomedical Engineering. 38: 65-78. PMID 21175404 DOI: 10.1615/Critrevbiomedeng.V38.I1.60  0.342
2010 Hinshaw JL, Lee FT, Laeseke PF, Sampson LA, Brace C. Temperature isotherms during pulmonary cryoablation and their correlation with the zone of ablation. Journal of Vascular and Interventional Radiology : Jvir. 21: 1424-8. PMID 20688532 DOI: 10.1016/J.Jvir.2010.04.029  0.63
2010 Lubner MG, Brace CL, Hinshaw JL, Lee FT. Microwave tumor ablation: mechanism of action, clinical results, and devices. Journal of Vascular and Interventional Radiology : Jvir. 21: S192-203. PMID 20656229 DOI: 10.1016/J.Jvir.2010.04.007  0.388
2010 Andreano A, Huang Y, Meloni MF, Lee FT, Brace C. Microwaves create larger ablations than radiofrequency when controlled for power in ex vivo tissue Medical Physics. 37: 2967-2973. PMID 20632609 DOI: 10.1118/1.3432569  0.417
2010 Brace CL, Diaz TA, Hinshaw JL, Lee FT. Tissue contraction caused by radiofrequency and microwave ablation: a laboratory study in liver and lung. Journal of Vascular and Interventional Radiology : Jvir. 21: 1280-6. PMID 20537559 DOI: 10.1016/J.Jvir.2010.02.038  0.378
2010 Hinshaw JL, Littrup PJ, Durick N, Leung W, Lee FT, Sampson L, Brace CL. Optimizing the protocol for pulmonary cryoablation: a comparison of a dual- and triple-freeze protocol. Cardiovascular and Interventional Radiology. 33: 1180-5. PMID 20437048 DOI: 10.1007/S00270-010-9868-0  0.314
2010 Rubert N, Bharat S, DeWall RJ, Andreano A, Brace C, Jiang J, Sampson L, Varghese T. Electrode displacement strain imaging of thermally-ablated liver tissue in an in vivo animal model. Medical Physics. 37: 1075-82. PMID 20384243 DOI: 10.1118/1.3301603  0.368
2010 Jiang J, Brace C, Andreano A, DeWall RJ, Rubert N, Fisher TG, Varghese T, Lee F, Hall TJ. Ultrasound-based relative elastic modulus imaging for visualizing thermal ablation zones in a porcine model. Physics in Medicine and Biology. 55: 2281-306. PMID 20354279 DOI: 10.1088/0031-9155/55/8/011  0.319
2010 Rubert N, Bharat S, DeWall R, Andreano A, Brace C, Jiang J, Sampson L, Zagzebski J, Lee F, Varghese T. TU-E-201C-05: Electrode Displacement Strain Imaging for Monitoring In-Vivo Ablative Therapies Medical Physics. 37: 3405-3405. DOI: 10.1118/1.3469307  0.34
2009 Laeseke PF, Lee FT, van der Weide DW, Brace CL. Multiple-Antenna Microwave Ablation: Spatially Distributing Power Improves Thermal Profiles and Reduces Invasiveness. Journal of Interventional Oncology. 2: 65-72. PMID 21857888  0.722
2009 Laeseke PF, Lee FT, Sampson LA, van der Weide DW, Brace CL. Microwave ablation versus radiofrequency ablation in the kidney: high-power triaxial antennas create larger ablation zones than similarly sized internally cooled electrodes. Journal of Vascular and Interventional Radiology : Jvir. 20: 1224-9. PMID 19616970 DOI: 10.1016/J.Jvir.2009.05.029  0.758
2009 Wang P, Brace CL, Converse MC, Webster JG. Tumor boundary estimation through time-domain peaks monitoring: numerical predictions and experimental results in tissue-mimicking phantoms. Ieee Transactions On Bio-Medical Engineering. 56: 2634-41. PMID 19567338 DOI: 10.1109/Tbme.2009.2025963  0.309
2009 Brace CL, Hinshaw JL, Laeseke PF, Sampson LA, Lee FT. Pulmonary thermal ablation: comparison of radiofrequency and microwave devices by using gross pathologic and CT findings in a swine model. Radiology. 251: 705-11. PMID 19336667 DOI: 10.1148/Radiol.2513081564  0.691
2009 Brace CL. Radiofrequency and microwave ablation of the liver, lung, kidney, and bone: what are the differences? Current Problems in Diagnostic Radiology. 38: 135-43. PMID 19298912 DOI: 10.1067/J.Cpradiol.2007.10.001  0.382
2009 Jiang J, Varghese T, Brace CL, Madsen EL, Hall TJ, Bharat S, Hobson MA, Zagzebski JA, Lee FT. Young's modulus reconstruction for radio-frequency ablation electrode-induced displacement fields: a feasibility study. Ieee Transactions On Medical Imaging. 28: 1325-34. PMID 19258195 DOI: 10.1109/Tmi.2009.2015355  0.339
2009 Brace CL. Microwave ablation technology: what every user should know. Current Problems in Diagnostic Radiology. 38: 61-7. PMID 19179193 DOI: 10.1067/J.Cpradiol.2007.08.011  0.329
2009 Brace CL, Sampson LA, Hinshaw JL, Sandhu N, Lee FT. Radiofrequency ablation: simultaneous application of multiple electrodes via switching creates larger, more confluent ablations than sequential application in a large animal model. Journal of Vascular and Interventional Radiology : Jvir. 20: 118-24. PMID 19019701 DOI: 10.1016/J.Jvir.2008.09.021  0.372
2009 Schenning R, Sampson L, Hinshaw L, Lee F, Brace C. Abstract No. 352: The Importance of Antenna Spacing During Microwave Ablation: Results at 2.45GHz in an Ex Vivo Bovine Liver Model Journal of Vascular and Interventional Radiology. 20: S131. DOI: 10.1016/J.Jvir.2008.12.347  0.413
2008 Hinshaw JL, Sampson L, Lee FT, Laeseke PF, Brace CL. Does selective intubation increase ablation zone size during pulmonary cryoablation? Journal of Vascular and Interventional Radiology : Jvir. 19: 1497-501. PMID 18662888 DOI: 10.1016/J.Jvir.2008.06.009  0.625
2008 Durick NA, Laeseke PF, Broderick LS, Lee FT, Sampson LA, Frey TM, Warner TF, Fine JP, van der Weide DW, Brace CL. Microwave ablation with triaxial antennas tuned for lung: results in an in vivo porcine model. Radiology. 247: 80-7. PMID 18292471 DOI: 10.1148/Radiol.2471062123  0.736
2008 Sandhu N, Hinshaw L, Lee F, Brace C. Abstract No. 108: Sequential Versus Simultaneous Application of Multiple-Electrodes for RF Ablation: Quantifying Thermal Synergy Journal of Vascular and Interventional Radiology. 19: S42-S43. DOI: 10.1016/J.Jvir.2007.12.120  0.349
2007 Laeseke PF, Sampson LA, Frey TM, Mukherjee R, Winter TC, Lee FT, Brace CL. Multiple-electrode radiofrequency ablation: comparison with a conventional cluster electrode in an in vivo porcine kidney model. Journal of Vascular and Interventional Radiology : Jvir. 18: 1005-10. PMID 17675619 DOI: 10.1016/J.Jvir.2007.05.010  0.624
2007 Brace CL, Laeseke PF, Sampson LA, Frey TM, van der Weide DW, Lee FT. Microwave ablation with multiple simultaneously powered small-gauge triaxial antennas: results from an in vivo swine liver model. Radiology. 244: 151-6. PMID 17581900 DOI: 10.1148/Radiol.2441052054  0.741
2007 Brace CL, Laeseke PF, Sampson LA, Frey TM, Mukherjee R, Lee FT. Radiofrequency ablation with a high-power generator: device efficacy in an in vivo porcine liver model. International Journal of Hyperthermia : the Official Journal of European Society For Hyperthermic Oncology, North American Hyperthermia Group. 23: 387-94. PMID 17558738 DOI: 10.1080/02656730701397858  0.621
2007 Laeseke PF, Frey TM, Brace CL, Sampson LA, Winter TC, Ketzler JR, Lee FT. Multiple-electrode radiofrequency ablation of hepatic malignancies: initial clinical experience. Ajr. American Journal of Roentgenology. 188: 1485-94. PMID 17515366 DOI: 10.2214/Ajr.06.1004  0.645
2007 Brace CL, Laeseke PF, Sampson LA, Frey TM, van der Weide DW, Lee FT. Microwave ablation with a single small-gauge triaxial antenna: in vivo porcine liver model. Radiology. 242: 435-40. PMID 17255414 DOI: 10.1148/Radiol.2422051411  0.747
2006 Brace CL, Laeseke PF, Prasad V, Lee FT. Electrical isolation during radiofrequency ablation: 5% dextrose in water provides better protection than saline. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 5021-4. PMID 17947126 DOI: 10.1109/IEMBS.2006.260086  0.569
2006 Laeseke PF, Sampson LA, Haemmerich D, Brace CL, Fine JP, Frey TM, Winter TC, Lee FT. Multiple-electrode radiofrequency ablation creates confluent areas of necrosis: in vivo porcine liver results. Radiology. 241: 116-24. PMID 16928978 DOI: 10.1148/Radiol.2411051271  0.625
2006 Laeseke PF, Sampson LA, Brace CL, Winter TC, Fine JP, Lee FT. Unintended thermal injuries from radiofrequency ablation: protection with 5% dextrose in water. Ajr. American Journal of Roentgenology. 186: S249-54. PMID 16632684 DOI: 10.2214/Ajr.04.1240  0.609
2005 Brace CL, Laeseke PF, van der Weide DW, Lee FT. Microwave Ablation With a Triaxial Antenna: Results in ex vivo Bovine Liver. Ieee Transactions On Microwave Theory and Techniques. 53: 215-220. PMID 18079981 DOI: 10.1109/TMTT.2004.839308  0.732
2005 Laeseke PF, Sampson LA, Haemmerich D, Brace CL, Fine JP, Frey TM, Winter TC, Lee FT. Multiple-electrode radiofrequency ablation: simultaneous production of separate zones of coagulation in an in vivo porcine liver model. Journal of Vascular and Interventional Radiology : Jvir. 16: 1727-35. PMID 16371542 DOI: 10.1097/01.Rvi.000018362.17771.B0  0.637
2004 Brace CL, van der Weide DW, Lee FT, Laeseke PF, Sampson L. Analysis and experimental validation of a triaxial antenna for microwave tumor ablation. Ieee Mtt-S International Microwave Symposium Digest. Ieee Mtt-S International Microwave Symposium. 3: 1437-1440. PMID 18079982 DOI: 10.1109/MWSYM.2004.1338842  0.708
Show low-probability matches.