Year |
Citation |
Score |
2020 |
Nussbaum MA, Neumann WP, Radwin RG. Editorial. Iise Transactions On Occupational Ergonomics and Human Factors. 8: 61-62. PMID 33092491 DOI: 10.1080/24725838.2020.1829882 |
0.365 |
|
2018 |
Greene RL, Hu YH, Difranco N, Wang X, Lu ML, Bao S, Lin JH, Radwin RG. Predicting Sagittal Plane Lifting Postures From Image Bounding Box Dimensions. Human Factors. 18720818791367. PMID 30091947 DOI: 10.1177/0018720818791367 |
0.498 |
|
2018 |
Akkas O, Hu YH, Lee C, Bao S, Harris-Adamson C, Lin J, Meyers A, Rempel D, Radwin RG. How Do Computer Vision Upper Extremity Exposure Measures Compare Against Manual Measures? Proceedings of the Human Factors and Ergonomics Society Annual Meeting. 62: 960-961. DOI: 10.1177/1541931218621221 |
0.441 |
|
2016 |
Radwin RG, Chourasia A, Fronczak FJ, Subedi Y, Howery R, Yen TY, Sesto ME, Irwin CB. Predicting tool operator capacity to react against torque within acceptable handle deflection limits in automotive assembly. Applied Ergonomics. 54: 205-11. PMID 26851480 DOI: 10.1016/J.Apergo.2015.12.001 |
0.706 |
|
2015 |
Chen KB, Xu X, Lin JH, Radwin RG. Evaluation of older driver head functional range of motion using portable immersive virtual reality. Experimental Gerontology. 70: 150-6. PMID 26315289 DOI: 10.1016/J.Exger.2015.08.010 |
0.44 |
|
2015 |
Irwin CB, Towles JD, Radwin RG. Multiaxis grip characteristics for varying handle diameters and effort. Human Factors. 57: 227-37. PMID 25850154 DOI: 10.1177/0018720814544212 |
0.731 |
|
2015 |
Xu X, Chen KB, Lin JH, Radwin RG. The accuracy of the Oculus Rift virtual reality head-mounted display during cervical spine mobility measurement. Journal of Biomechanics. 48: 721-4. PMID 25636855 DOI: 10.1016/J.Jbiomech.2015.01.005 |
0.475 |
|
2015 |
Radwin RG, Azari DP, Lindstrom MJ, Ulin SS, Armstrong TJ, Rempel D. A frequency-duty cycle equation for the ACGIH hand activity level. Ergonomics. 58: 173-83. PMID 25343340 DOI: 10.1080/00140139.2014.966154 |
0.432 |
|
2015 |
Akkas O, Azari DP, Chen CH, Hu YH, Ulin SS, Armstrong TJ, Rempel D, Radwin RG. A hand speed-duty cycle equation for estimating the ACGIH hand activity level rating. Ergonomics. 58: 184-94. PMID 25343278 DOI: 10.1080/00140139.2014.966155 |
0.448 |
|
2015 |
Chen KB, Xu X, Lin J, Radwin RG. Evaluation of Older Driver Functional Range of Motion using Virtual Reality Proceedings of the Human Factors and Ergonomics Society Annual Meeting. 59: 1279-1279. DOI: 10.1177/1541931215591206 |
0.413 |
|
2014 |
Radwin RG, Chourasia AO, Howery RS, Fronczak FJ, Yen TY, Subedi Y, Sesto ME. Factors influencing power hand tool fastening accuracy and reaction forces. Human Factors. 56: 657-68. PMID 25029892 DOI: 10.1177/0018720813507952 |
0.387 |
|
2014 |
Akas O, Azari D, Chen CH, Hu YH, Armstrong TJ, Ulin SS, Radwin RG. An equation for estimating hand activity level based on measured hand speed and duty cycle Proceedings of the Human Factors and Ergonomics Society. 2014: 1600-1604. DOI: 10.1177/1541931214581333 |
0.462 |
|
2013 |
Irwin CB, Towles JD, Radwin RG. Development and application of a multi-axis dynamometer for measuring grip force. Ergonomics. 56: 1841-9. PMID 24134054 DOI: 10.1080/00140139.2013.847212 |
0.744 |
|
2010 |
Armstrong T, Cochran DJ, Bleed PA, Lin JH, Freivalds A, Radwin RG, Rempel DM. Hand tool ergonomics - Past and present Proceedings of the Human Factors and Ergonomics Society. 2: 1145-1148. DOI: 10.1518/107118110X12829369834041 |
0.474 |
|
2009 |
Chourasia AO, Sesto ME, Block WF, Radwin RG. Prolonged mechanical and physiological changes in the upper extremity following short-term simulated power hand tool use. Ergonomics. 52: 15-24. PMID 19308816 DOI: 10.1080/00140130802480877 |
0.327 |
|
2009 |
Armstrong T, Radwin R, Marras B. Festschrift for Dr Don B. Chaffin. Ergonomics. 52: 1-2. PMID 19308814 DOI: 10.1080/00140130802479796 |
0.359 |
|
2008 |
Irwin CB, Radwin RG. A new method for estimating hand internal loads from external force measurements. Ergonomics. 51: 156-67. PMID 17891593 DOI: 10.1080/00140130701526408 |
0.758 |
|
2007 |
Ku CH, Radwin RG, Karsh BT. Power hand tool kinetics associated with upper limb injuries in an automobile assembly plant. Journal of Occupational and Environmental Hygiene. 4: 391-9. PMID 17474028 DOI: 10.1080/15459620701326521 |
0.371 |
|
2007 |
Irwin CB, Radwin RG. A novel dynamometer for describing forces and vectors in the long fingers during grip Proceedings of the Human Factors and Ergonomics Society. 2: 947-951. |
0.75 |
|
2005 |
Lin JH, Radwin R, Nembhard D. Ergonomics applications of a mechanical model of the human operator in power hand tool operation. Journal of Occupational and Environmental Hygiene. 2: 111-9; quiz D6-7. PMID 15764531 DOI: 10.1080/15459620590913155 |
0.572 |
|
2004 |
Edgren CS, Radwin RG, Irwin CB. Grip force vectors for varying handle diameters and hand sizes. Human Factors. 46: 244-51. PMID 15359674 DOI: 10.1518/Hfes.46.2.244.37337 |
0.749 |
|
2003 |
Lin JH, Radwin RG, Richard TG. Handle dynamics predictions for selected power hand tool applications. Human Factors. 45: 645-56. PMID 15055461 DOI: 10.1518/Hfes.45.4.645.27083 |
0.551 |
|
2003 |
Lin JH, Radwin RG, Richard TG. A single-degree-of-freedom dynamic model predicts the range of human responses to impulsive forces produced by power hand tools. Journal of Biomechanics. 36: 1845-52. PMID 14614938 DOI: 10.1016/S0021-9290(03)00214-8 |
0.595 |
|
2003 |
Lin JH, Radwin RG, Fronczak FJ, Richard TG. Forces associated with pneumatic power screwdriver operation: statics and dynamics. Ergonomics. 46: 1161-77. PMID 12933078 DOI: 10.1080/0014013031000139518 |
0.607 |
|
2003 |
Irwin CB, Radwin RG. A New Method for Estimating Biomechanical Loading in Grip Proceedings of the Human Factors and Ergonomics Society Annual Meeting. 47: 1126-1130. DOI: 10.1177/154193120304701005 |
0.676 |
|
2001 |
Szabo RL, Radwin RG, Henderson CJ. The influence of knife dullness on poultry processing operator exertions and the effectiveness of periodic knife steeling American Industrial Hygiene Association Journal. 62: 428-433. PMID 11549136 DOI: 10.1080/15298660108984644 |
0.302 |
|
2001 |
Lin JH, Radwin RG, Richard TG. Dynamic biomechanical model of the hand and arm in pistol grip power handtool usage. Ergonomics. 44: 295-312. PMID 11219761 DOI: 10.1080/00140130118167 |
0.572 |
|
2000 |
Lin J, Radwin RG, Richard TG. Development and Validation of a Dynamic Biomechanical Model for Power Hand Tool Torque Build-up Reaction Force Proceedings of the Human Factors and Ergonomics Society Annual Meeting. 44: 29-32. DOI: 10.1177/154193120004402908 |
0.547 |
|
2000 |
Lin JH, Radwin RG, Richard TG. Development and Validation of a Dynamic Biomechanical Model for Power Hand Tool Torque Build-up Reaction Force Proceedings of the Xivth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Association, 'Ergonomics For the New Millennium'. 29-32. |
0.357 |
|
2000 |
Edgren CS, Radwin RG. Power grip force magnitude and direction for varying cylindrical handle diameters and hand size Proceedings of the Xivth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Association, 'Ergonomics For the New Millennium'. 25-28. |
0.4 |
|
2000 |
Radwin RG, Lin JH, Richard TG. A biodynamic model of human reaction to impulsive torques encountered in hand tools Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 4: 2707-2710. |
0.35 |
|
1999 |
Radwin RG, Ruffalo BA. Computer key switch force-displacement characteristics and short-term effects on localized fatigue Ergonomics. 42: 160-170. PMID 9973878 DOI: 10.1080/001401399185865 |
0.336 |
|
1998 |
Szabo RL, Radwin RG, Henderson CJ. The Influence of Knife Sharpness on Poultry Processing Operator Exertions and the Effectiveness of Re-Sharpening Proceedings of the Human Factors and Ergonomics Society Annual Meeting. 42: 921-925. DOI: 10.1177/154193129804201218 |
0.327 |
|
1997 |
Oh SA, Radwin RG, Fronczak FJ. A dynamic mechanical model for hand force in right angle nutrunner operation Human Factors. 39: 497-506. PMID 9394642 DOI: 10.1518/001872097778827133 |
0.395 |
|
1997 |
Radwin RG, Jeng OJ. Activation force and travel effects on overexertion in repetitive key tapping Human Factors. 39: 130-140. PMID 9302885 DOI: 10.1518/001872097778940605 |
0.34 |
|
1997 |
Oh SA, Radwin RG. The effects of power hand tool dynamics and workstation design on handle kinematics and muscle activity International Journal of Industrial Ergonomics. 20: 59-74. DOI: 10.1016/S0169-8141(96)00033-9 |
0.314 |
|
1996 |
Carvalho AA, Radwin RG. A new method for extending the range of conductive polymer sensors for contact force International Journal of Industrial Ergonomics. 17: 285-290. DOI: 10.1016/0169-8141(95)00053-4 |
0.304 |
|
1995 |
Radwin RG, Oh S, Fronczak FJ. A Mechanical Model of Hand Force in Power Hand Tool Operation Proceedings of the Human Factors and Ergonomics Society Annual Meeting. 39: 548-552. DOI: 10.1177/154193129503901002 |
0.391 |
|
1994 |
Oh S, Radwin RG. Dynamics of Power Hand Tools on Operator Hand and Arm Stability Proceedings of the Human Factors and Ergonomics Society Annual Meeting. 38: 602-606. DOI: 10.1177/154193129403801013 |
0.302 |
|
1993 |
Oh S, Radwin RG. Pistol grip power tool handle and trigger size effects on grip exertions and operator preference Human Factors. 35: 551-569. PMID 8244414 DOI: 10.1177/001872089303500311 |
0.407 |
|
1992 |
Radwin RG, Oh S, Jensen TR, Webster JG. External finger forces in submaximal five-finger static pinch prehension. Ergonomics. 35: 275-88. PMID 1572337 DOI: 10.1080/00140139208967813 |
0.389 |
|
1991 |
Radwin RG, Masters GP, Lupton FW. A linear force-summing hand dynamometer independent of point of application Applied Ergonomics. 22: 339-345. DOI: 10.1016/0003-6870(91)90393-V |
0.398 |
|
1990 |
Radwin RG, Armstrong TJ, Vanbergeijk E. Vibration exposure for selected power hand tools used in automobile assembly. American Industrial Hygiene Association Journal. 51: 510-8. PMID 2220569 DOI: 10.1080/15298669091370013 |
0.514 |
|
1990 |
Radwin RG, Armstrong TJ, Chaffin DB, Langolf GD, Albers JW. Hand-arm frequency-weighted vibration effects on tactility International Journal of Industrial Ergonomics. 6: 75-82. DOI: 10.1016/0169-8141(90)90052-4 |
0.634 |
|
1990 |
Ulin SS, Armstrong TJ, Radwin RG. Use of computer aided drafting for analysis and control of posture in manual work Applied Ergonomics. 21: 143-151. DOI: 10.1016/0003-6870(90)90137-M |
0.461 |
|
1989 |
Radwin RG, VanBergeijk E, Armstrong TJ. Muscle response to pneumatic hand tool torque reaction forces. Ergonomics. 32: 655-74. PMID 2776745 DOI: 10.1080/00140138908966140 |
0.523 |
|
1987 |
Armstrong TJ, Fine LJ, Radwin RG, Silverstein BS. Ergonomics and the effects of vibration in hand-intensive work. Scandinavian Journal of Work, Environment & Health. 13: 286-9. PMID 3324309 DOI: 10.5271/Sjweh.2049 |
0.548 |
|
1987 |
Radwin RG, Armstrong TJ, Chaffin DB. Power hand tool vibration effects on grip exertions Ergonomics. 30: 833-855. DOI: 10.1080/00140138708969772 |
0.662 |
|
1986 |
Armstrong TJ, Radwin RG, Hansen DJ, Kennedy KW. Repetitive trauma disorders: job evaluation and design. Human Factors. 28: 325-36. PMID 3770763 DOI: 10.1177/001872088602800308 |
0.503 |
|
1986 |
Armstrong TJ, Radwin RG, Kennedy KW. Reach analysis using drawing board manikins and a micro-computer Journal of Biomechanics. 19: 483. DOI: 10.1016/0021-9290(86)90088-6 |
0.438 |
|
1985 |
Radwin RG, Armstrong TJ. Assessment of hand vibration exposure on an assembly line. American Industrial Hygiene Association Journal. 46: 211-9. PMID 4003272 DOI: 10.1080/15298668591394680 |
0.506 |
|
Show low-probability matches. |