Year |
Citation |
Score |
2023 |
Huo M, Giridharan GA, Sethu P, Qu P, Qin K, Wang Y. Numerical simulation analysis of multi-scale computational fluid dynamics on hemodynamic parameters modulated by pulsatile working modes for the centrifugal and axial left ventricular assist devices. Computers in Biology and Medicine. 169: 107788. PMID 38091724 DOI: 10.1016/j.compbiomed.2023.107788 |
0.315 |
|
2023 |
Yang W, Conover TA, Figliola RS, Giridharan GA, Marsden AL, Rodefeld MD. Passive performance evaluation and validation of a viscous impeller pump for subpulmonary fontan circulatory support. Scientific Reports. 13: 12668. PMID 37542111 DOI: 10.1038/s41598-023-38559-y |
0.392 |
|
2023 |
Tan Z, Huo M, Qin K, El-Baz AS, Sethu P, Wang Y, Giridharan GA. A sensorless, physiologic feedback control strategy to increase vascular pulsatility for rotary blood pumps. Biomedical Signal Processing and Control. 83. PMID 36936779 DOI: 10.1016/j.bspc.2023.104640 |
0.339 |
|
2023 |
Yang W, Conover T, Giridharan G, Figliola R, Marsden A, Rodefeld M. Passive Performance Evaluation and Validation of a Viscous Impeller Pump for Subpulmonary Fontan Circulatory Support. Research Square. PMID 36909557 DOI: 10.21203/rs.3.rs-2584661/v1 |
0.382 |
|
2022 |
Giridharan GA, Berg IC, Ismail E, Nguyen KT, Hecking J, Kirklin JK, Cheng X, Sethu P. Loss of pulsatility with continuous-flow left ventricular assist devices and the significance of the arterial endothelium in von-Willebrand factor production and degradation. Artificial Organs. PMID 36404709 DOI: 10.1111/aor.14456 |
0.301 |
|
2021 |
Liang L, Qin K, El-Baz AS, Roussel TJ, Sethu P, Giridharan GA, Wang Y. A Flow Sensor-Based Suction-Index Control Strategy for Rotary Left Ventricular Assist Devices. Sensors (Basel, Switzerland). 21. PMID 34696104 DOI: 10.3390/s21206890 |
0.43 |
|
2021 |
Wang Y, Wang J, Peng J, Huo M, Yang Z, Giridharan GA, Luan Y, Qin K. Effects of a Short-Term Left Ventricular Assist Device on Hemodynamics in a Heart Failure Patient-Specific Aorta Model: A CFD Study. Frontiers in Physiology. 12: 733464. PMID 34621186 DOI: 10.3389/fphys.2021.733464 |
0.401 |
|
2021 |
Slaughter MS, Monreal G, Koenig SC, Giridharan GA, Tompkins LH, Jimenez JH. Demonstration of proof-of-concept of StrokeShield system for complete closure and occlusion of the left atrial appendage for non-valvular atrial fibrillation therapy. Plos One. 16: e0253299. PMID 34157041 DOI: 10.1371/journal.pone.0253299 |
0.324 |
|
2020 |
Miller J, Meki M, Ou Q, George SA, Gams A, Abouleisa RRE, Tang XL, Ahern BM, Giridharan GA, El-Baz A, Hill BG, Satin J, Conklin DJ, Moslehi J, Bolli R, et al. Heart slice culture system reliably demonstrates clinical drug-related cardiotoxicity. Toxicology and Applied Pharmacology. 115213. PMID 32877659 DOI: 10.1016/J.Taap.2020.115213 |
0.339 |
|
2020 |
Hammouda K, Khalifa F, Abdeltawab H, Elnakib A, Giridharan GA, Zhu M, Ng CK, Dassanayaka S, Kong M, Darwish HE, Mohamed TMA, Jones SP, El-Baz A. A New Framework for Performing Cardiac Strain Analysis from Cine MRI Imaging in Mice. Scientific Reports. 10: 7725. PMID 32382124 DOI: 10.1038/S41598-020-64206-X |
0.322 |
|
2020 |
Ou Q, Abouleisa RRE, Tang XL, Juhardeen HR, Meki MH, Miller JM, Giridharan G, El-Baz A, Bolli R, Mohamed TMA. Slicing and Culturing Pig Hearts under Physiological Conditions. Journal of Visualized Experiments : Jove. PMID 32250357 DOI: 10.3791/60913 |
0.349 |
|
2020 |
Wang Y, Peng J, Rodefeld MD, Luan Y, Giridharan GA. A sensorless physiologic control strategy for continuous flow cavopulmonary circulatory support devices Biomedical Signal Processing and Control. 62: 102130. DOI: 10.1016/J.Bspc.2020.102130 |
0.46 |
|
2020 |
Liang L, Meki M, Wang W, Sethu P, El-Baz A, Giridharan GA, Wang Y. A suction index based control system for rotary blood pumps Biomedical Signal Processing and Control. 62: 102057. DOI: 10.1016/J.Bspc.2020.102057 |
0.478 |
|
2019 |
Rodefeld MD, Marsden A, Figliola R, Jonas T, Neary M, Giridharan GA. Cavopulmonary assist: Long-term reversal of the Fontan paradox. The Journal of Thoracic and Cardiovascular Surgery. PMID 31564543 DOI: 10.1016/J.Jtcvs.2019.06.112 |
0.413 |
|
2019 |
Kandil H, Soliman A, Ghazal M, Mahmoud A, Shalaby A, Keynton R, Elmaghraby A, Giridharan G, El-Baz A. A Novel Framework for Early Detection of Hypertension using Magnetic Resonance Angiography. Scientific Reports. 9: 11105. PMID 31366941 DOI: 10.1038/S41598-019-47368-1 |
0.312 |
|
2019 |
Meki MH, Wang Y, Sethu P, Ghazal M, El-Baz A, Giridharan GA. A Sensorless Rotational Speed-based Control System for Continuous Flow Left Ventricular Assist Devices. Ieee Transactions On Bio-Medical Engineering. PMID 31329102 DOI: 10.1109/Tbme.2019.2928826 |
0.551 |
|
2019 |
Ou Q, Jacobson Z, Abouleisa R, Tang XL, Hindi S, Kumar A, Ivey KN, Giridharan GA, Al-Baz A, Brittian K, Rood B, Lin YH, Watson SA, Perbellini F, McKinsey TA, et al. A Physiological Biomimetic Culture System for Pig and Human Heart Slices. Circulation Research. PMID 31310161 DOI: 10.1161/Circresaha.119.314996 |
0.367 |
|
2019 |
Abouleisa R, Ou Q, Jacobson Z, Tang X, Hindi SM, Kumar A, Ivey KN, Giridharan G, Al-Baz A, Brittian K, Rood B, Hill BG, Jones SP, Bolli R, Mohamed TM. Abstract 208: Reliable Biomimetic Culture System for Pig and Human Heart Slices Circulation Research. 125. DOI: 10.1161/Res.125.Suppl_1.208 |
0.311 |
|
2019 |
Wang Y, Koenig SC, Wu ZJ, Slaughter MS, Giridharan GA. Sensorless Physiologic Control, Suction Prevention, and Flow Balancing Algorithm for Rotary Biventricular Assist Devices Ieee Transactions On Control Systems Technology. 27: 717-729. DOI: 10.1109/Tcst.2017.2773518 |
0.503 |
|
2018 |
Haglund TA, Rajasekaran NS, Smood B, Giridharan GA, Hoopes CW, Holman WL, Mauchley DC, Prabhu SD, Pamboukian SV, Tallaj JA, Rajapreyar IN, Kirklin JK, Sethu P. Evaluation of flow-modulation approaches in ventricular assist devices using an in-vitro endothelial cell culture model. The Journal of Heart and Lung Transplantation : the Official Publication of the International Society For Heart Transplantation. PMID 30503074 DOI: 10.1016/J.Healun.2018.10.007 |
0.42 |
|
2018 |
Chen Z, Jena SK, Giridharan GA, Sobieski MA, Koenig SC, Slaughter MS, Griffith BP, Wu ZJ. Shear stress and blood trauma under constant and pulse-modulated speed CF-VAD operations: CFD analysis of the HVAD. Medical & Biological Engineering & Computing. PMID 30406881 DOI: 10.1007/S11517-018-1922-0 |
0.377 |
|
2017 |
Wang Y, Koenig SC, Wu Z, Slaughter MS, Giridharan GA. Sensor-Based Physiologic Control Strategy for Biventricular Support with Rotary Blood Pumps. Asaio Journal (American Society For Artificial Internal Organs : 1992). PMID 28938308 DOI: 10.1097/Mat.0000000000000671 |
0.514 |
|
2017 |
Chen Z, Jena SK, Giridharan GA, Koenig SC, Slaughter MS, Griffith BP, Wu ZJ. Flow Features and Device-Induced Blood Trauma in CF-VADs under a pulsatile blood flow condition: A CFD Comparative Study. International Journal For Numerical Methods in Biomedical Engineering. PMID 28859253 DOI: 10.1002/Cnm.2924 |
0.447 |
|
2017 |
Wang Y, Koenig SC, Sobieski MA, Slaughter MS, Giridharan GA. Hemodynamic Benefits of Counterpulsation, Implantable, Percutaneous, and Intraaortic Rotary Blood Pumps: An In-Silico and In Vitro Study. Cardiovascular Engineering and Technology. PMID 28707188 DOI: 10.1007/S13239-017-0314-1 |
0.552 |
|
2017 |
Soucy KG, Bartoli CR, Phillips D, Giridharan GA, Sobieski MA, Wead WB, Dowling RD, Wu ZJ, Prabhu SD, Slaughter MS, Koenig SC. Continuous-Flow Left Ventricular Assist Device Support Improves Myocardial Supply:Demand in Chronic Heart Failure. Annals of Biomedical Engineering. PMID 28168379 DOI: 10.1007/S10439-017-1804-X |
0.524 |
|
2016 |
Carnahan SR, Koenig SC, Sobieski MA, Schumer EM, Monreal G, Wang Y, Choi Y, Meuris BJ, Tompkins LH, Wu ZJ, Slaughter MS, Giridharan GA. Efficacy of Subcutaneous Electrocardiogram Leads for Synchronous Timing During Chronic Counterpulsation Therapy. Asaio Journal (American Society For Artificial Internal Organs : 1992). PMID 27984317 DOI: 10.1097/Mat.0000000000000498 |
0.485 |
|
2016 |
Patibandla PK, Rajasekaran NS, Shelar SB, Giridharan GA, Litovsky SH, Sethu P. Evaluation of the effect of diminished pulsatility as seen in continuous flow ventricular assist devices on arterial endothelial cell phenotype and function. The Journal of Heart and Lung Transplantation : the Official Publication of the International Society For Heart Transplantation. PMID 27138701 DOI: 10.1016/J.Healun.2016.03.008 |
0.336 |
|
2015 |
Ising MS, Sobieski MA, Slaughter MS, Koenig SC, Giridharan GA. Feasibility of Pump Speed Modulation for Restoring Vascular Pulsatility with Rotary Blood Pumps. Asaio Journal (American Society For Artificial Internal Organs : 1992). 61: 526-32. PMID 26102173 DOI: 10.1097/Mat.0000000000000262 |
0.457 |
|
2015 |
Schumer EM, Zoeller KA, Linsky PL, Monreal G, Choi Y, Giridharan GA, Sobieski MA, Slaughter MS, van Berkel VH. Feasibility Study of Pulsatile Left Ventricular Assist Device for Prolonged Ex Vivo Lung Perfusion. The Annals of Thoracic Surgery. 99: 1961-8. PMID 25921254 DOI: 10.1016/J.Athoracsur.2015.02.087 |
0.382 |
|
2015 |
Giridharan GA, Koenig SC, Soucy KG, Choi Y, Pirbodaghi T, Bartoli CR, Monreal G, Sobieski MA, Schumer E, Cheng A, Slaughter MS. Left ventricular volume unloading with axial and centrifugal rotary blood pumps. Asaio Journal (American Society For Artificial Internal Organs : 1992). 61: 292-300. PMID 25635936 DOI: 10.1097/Mat.0000000000000201 |
0.438 |
|
2015 |
Giridharan GA, Koenig SC, Soucy KG, Choi Y, Pirbodaghi T, Bartoli CR, Monreal G, Sobieski MA, Schumer E, Cheng A, Slaughter MS. Hemodynamic changes and retrograde flow in LVAD failure. Asaio Journal (American Society For Artificial Internal Organs : 1992). 61: 282-91. PMID 25635935 DOI: 10.1097/Mat.0000000000000200 |
0.469 |
|
2015 |
Nguyen MD, Tinney JP, Ye F, Elnakib AA, Yuan F, El-Baz A, Sethu P, Keller BB, Giridharan GA. Effects of physiologic mechanical stimulation on embryonic chick cardiomyocytes using a microfluidic cardiac cell culture model. Analytical Chemistry. 87: 2107-13. PMID 25539164 DOI: 10.1021/Ac503716Z |
0.362 |
|
2015 |
Soucy KG, Giridharan GA, Choi Y, Sobieski MA, Monreal G, Cheng A, Schumer E, Slaughter MS, Koenig SC. Rotary pump speed modulation for generating pulsatile flow and phasic left ventricular volume unloading in a bovine model of chronic ischemic heart failure. The Journal of Heart and Lung Transplantation : the Official Publication of the International Society For Heart Transplantation. 34: 122-31. PMID 25447573 DOI: 10.1016/J.Healun.2014.09.017 |
0.527 |
|
2015 |
Soucy KG, Smith EF, Monreal G, Rokosh G, Keller BB, Yuan F, Matheny RG, Fallon AM, Lewis BC, Sherwood LC, Sobieski MA, Giridharan GA, Koenig SC, Slaughter MS. Feasibility study of particulate extracellular matrix (P-ECM) and left ventricular assist device (HVAD) therapy in chronic ischemic heart failure bovine model. Asaio Journal (American Society For Artificial Internal Organs : 1992). 61: 161-9. PMID 25423120 DOI: 10.1097/Mat.0000000000000178 |
0.412 |
|
2015 |
Wang Y, Koenig SC, Slaughter MS, Giridharan GA. Suction prevention and physiologic control of continuous flow left ventricular assist devices using intrinsic pump parameters. Asaio Journal (American Society For Artificial Internal Organs : 1992). 61: 170-7. PMID 25396276 DOI: 10.1097/Mat.0000000000000168 |
0.522 |
|
2015 |
Wang Y, Koenig SC, Slaughter MS, Giridharan GA. Rotary blood pump control strategy for preventing left ventricular suction. Asaio Journal (American Society For Artificial Internal Organs : 1992). 61: 21-30. PMID 25248043 DOI: 10.1097/Mat.0000000000000152 |
0.507 |
|
2014 |
Patibandla PK, Rogers AJ, Giridharan GA, Pallero MA, Murphy-Ullrich JE, Sethu P. Hyperglycemic arterial disturbed flow niche as an in vitro model of atherosclerosis. Analytical Chemistry. 86: 10948-54. PMID 25279658 DOI: 10.1021/Ac503294P |
0.356 |
|
2014 |
Koenig SC, Jimenez JH, West SD, Sobieski MA, Choi Y, Monreal G, Giridharan GA, Soucy KG, Slaughter MS. Early feasibility testing and engineering development of a sutureless beating heart connector for left ventricular assist devices. Asaio Journal (American Society For Artificial Internal Organs : 1992). 60: 617-25. PMID 25238500 DOI: 10.1097/Mat.0000000000000134 |
0.498 |
|
2014 |
Slaughter MS, Soucy KG, Matheny RG, Lewis BC, Hennick MF, Choi Y, Monreal G, Sobieski MA, Giridharan GA, Koenig SC. Development of an extracellular matrix delivery system for effective intramyocardial injection in ischemic tissue. Asaio Journal (American Society For Artificial Internal Organs : 1992). 60: 730-6. PMID 25232775 DOI: 10.1097/Mat.0000000000000146 |
0.381 |
|
2014 |
Giridharan GA, Ising M, Sobieski MA, Koenig SC, Chen J, Frankel S, Rodefeld MD. Cavopulmonary assist for the failing Fontan circulation: impact of ventricular function on mechanical support strategy. Asaio Journal (American Society For Artificial Internal Organs : 1992). 60: 707-15. PMID 25158887 DOI: 10.1097/Mat.0000000000000135 |
0.5 |
|
2014 |
Giridharan GA, Koenig SC, Slaughter MS. Do axial-flow LVADs unload better than centrifugal-flow LVADs? Asaio Journal (American Society For Artificial Internal Organs : 1992). 60: 137-9. PMID 24577367 DOI: 10.1097/Mat.0000000000000055 |
0.326 |
|
2014 |
Tamez D, LaRose JA, Shambaugh C, Chorpenning K, Soucy KG, Sobieski MA, Sherwood L, Giridharan GA, Monreal G, Koenig SC, Slaughter MS. Early feasibility testing and engineering development of the transapical approach for the HeartWare MVAD ventricular assist system. Asaio Journal (American Society For Artificial Internal Organs : 1992). 60: 170-7. PMID 24399057 DOI: 10.1097/Mat.0000000000000038 |
0.491 |
|
2014 |
Monreal G, Sherwood LC, Sobieski MA, Giridharan GA, Slaughter MS, Koenig SC. Large animal models for left ventricular assist device research and development. Asaio Journal (American Society For Artificial Internal Organs : 1992). 60: 2-8. PMID 24270232 DOI: 10.1097/Mat.0000000000000005 |
0.447 |
|
2013 |
Nguyen MD, Tinney JP, Yuan F, Roussel TJ, El-Baz A, Giridharan G, Keller BB, Sethu P. Cardiac cell culture model as a left ventricle mimic for cardiac tissue generation. Analytical Chemistry. 85: 8773-9. PMID 23952579 DOI: 10.1021/Ac401910D |
0.417 |
|
2013 |
Bartoli CR, Sherwood LC, Giridharan GA, Slaughter MS, Wead WB, Prabhu SD, Koenig SC. Bovine model of chronic ischemic cardiomyopathy: implications for ventricular assist device research. Artificial Organs. 37: E202-14. PMID 23876076 DOI: 10.1111/Aor.12129 |
0.477 |
|
2013 |
Soucy KG, Koenig SC, Sobieski MA, Slaughter MS, Giridharan GA. Fault detection in rotary blood pumps using motor speed response. Asaio Journal (American Society For Artificial Internal Organs : 1992). 59: 410-9. PMID 23820281 DOI: 10.1097/Mat.0B013E3182976838 |
0.392 |
|
2013 |
Soucy KG, Koenig SC, Giridharan GA, Sobieski MA, Slaughter MS. Rotary pumps and diminished pulsatility: do we need a pulse? Asaio Journal (American Society For Artificial Internal Organs : 1992). 59: 355-66. PMID 23820272 DOI: 10.1097/Mat.0B013E31829F9Bb3 |
0.499 |
|
2013 |
Ising MS, Koenig SC, Sobieski MA, Slaughter MS, Giridharan GA. Flow modulation algorithms for intra-aortic rotary blood pumps to minimize coronary steal. Asaio Journal (American Society For Artificial Internal Organs : 1992). 59: 261-8. PMID 23644613 DOI: 10.1097/Mat.0B013E31828Fd6C8 |
0.456 |
|
2013 |
Sherwood LC, Sobieski MA, Koenig SC, Giridharan GA, Slaughter MS. Benefits of aggressive medical management in a bovine model of chronic ischemic heart failure. Asaio Journal (American Society For Artificial Internal Organs : 1992). 59: 221-9. PMID 23644608 DOI: 10.1097/Mat.0B013E3182894E66 |
0.335 |
|
2013 |
Soucy KG, Koenig SC, Giridharan GA, Sobieski MA, Slaughter MS. Defining pulsatility during continuous-flow ventricular assist device support. The Journal of Heart and Lung Transplantation : the Official Publication of the International Society For Heart Transplantation. 32: 581-7. PMID 23540401 DOI: 10.1016/J.Healun.2013.02.010 |
0.511 |
|
2013 |
Giridharan GA, Koenig SC, Kennington J, Sobieski MA, Chen J, Frankel SH, Rodefeld MD. Performance evaluation of a pediatric viscous impeller pump for Fontan cavopulmonary assist. The Journal of Thoracic and Cardiovascular Surgery. 145: 249-57. PMID 22421403 DOI: 10.1016/J.Jtcvs.2012.01.082 |
0.328 |
|
2013 |
Soucy KG, Graham JD, Benzinger CJ, Sharp MK, Giridharan GA, Sobieski MA, Slaughter MS, Koenig SC. Apical-Ventricular Cannula for Aortic Valve Bypass Therapy Cardiovascular Engineering and Technology. 4: 161-170. DOI: 10.1007/S13239-013-0144-8 |
0.452 |
|
2013 |
Kerlo AEM, Delorme YT, Xu D, Frankel SH, Giridharan GA, Rodefeld MD, Chen J. Experimental characterization of powered Fontan hemodynamics in an idealized total cavopulmonary connection model Experiments in Fluids. 54. DOI: 10.1007/S00348-013-1581-8 |
0.413 |
|
2012 |
Giridharan GA, Lee TJ, Ising M, Sobieski MA, Koenig SC, Gray LA, Slaughter MS. Miniaturization of mechanical circulatory support systems. Artificial Organs. 36: 731-9. PMID 22882443 DOI: 10.1111/J.1525-1594.2012.01523.X |
0.442 |
|
2012 |
Sobieski MA, Giridharan GA, Ising M, Koenig SC, Slaughter MS. Blood trauma testing of CentriMag and RotaFlow centrifugal flow devices: a pilot study. Artificial Organs. 36: 677-82. PMID 22882437 DOI: 10.1111/J.1525-1594.2012.01514.X |
0.408 |
|
2012 |
Giridharan GA, Cheng RC, Glower JS, Ewert DL, Sobieski MA, Slaughter MS, Koenig SC. Control strategies for afterload reduction with an artificial vasculature device. Asaio Journal (American Society For Artificial Internal Organs : 1992). 58: 353-62. PMID 22635010 DOI: 10.1097/Mat.0B013E318256Bb50 |
0.516 |
|
2012 |
Giridharan GA, Bartoli CR, Spence PA, Dowling RD, Koenig SC. Counterpulsation with symphony prevents retrograde carotid, aortic, and coronary flows observed with intra-aortic balloon pump support. Artificial Organs. 36: 600-6. PMID 22591355 DOI: 10.1111/J.1525-1594.2012.01456.X |
0.425 |
|
2012 |
Bartoli CR, Wead WB, Giridharan GA, Prabhu SD, Koenig SC, Dowling RD. Mechanism of myocardial ischemia with an anomalous left coronary artery from the right sinus of Valsalva. The Journal of Thoracic and Cardiovascular Surgery. 144: 402-8. PMID 22564915 DOI: 10.1016/J.Jtcvs.2011.08.056 |
0.335 |
|
2012 |
Khalifa F, Beache GM, Gimel'farb G, Giridharan GA, El-Baz A. Accurate automatic analysis of cardiac cine images. Ieee Transactions On Bio-Medical Engineering. 59: 445-55. PMID 22057040 DOI: 10.1109/Tbme.2011.2174235 |
0.356 |
|
2012 |
Warren S, Giridharan GA, Dowling RD, Spence PA, Tompkins L, Gratz E, Sherwood LC, Sobieski MA, Bartoli CR, Slaughter MS, Keynton RS, Koenig SC. Feasibility of Subcutaneous ECG Leads for Synchronized Timing of a Counterpulsation Device Cardiovascular Engineering and Technology. 3: 17-25. DOI: 10.1007/S13239-011-0074-2 |
0.422 |
|
2011 |
Estrada R, Giridharan GA, Nguyen MD, Prabhu SD, Sethu P. Microfluidic endothelial cell culture model to replicate disturbed flow conditions seen in atherosclerosis susceptible regions. Biomicrofluidics. 5: 32006-3200611. PMID 22662029 DOI: 10.1063/1.3608137 |
0.33 |
|
2011 |
Giridharan GA, Sobieski MA, Ising M, Slaughter MS, Koenig SC. Blood trauma testing for mechanical circulatory support devices. Biomedical Instrumentation & Technology / Association For the Advancement of Medical Instrumentation. 45: 334-9. PMID 21812617 DOI: 10.2345/0899-8205-45.4.334 |
0.386 |
|
2011 |
Giridharan GA, Lederer C, Berthe A, Goubergrits L, Hutzenlaub J, Slaughter MS, Dowling RD, Spence PA, Koenig SC. Flow dynamics of a novel counterpulsation device characterized by CFD and PIV modeling Medical Engineering and Physics. 33: 1193-1202. PMID 21680224 DOI: 10.1016/J.Medengphy.2011.05.008 |
0.396 |
|
2011 |
Rodefeld MD, Frankel SH, Giridharan GA. Cavopulmonary assist: (em)powering the univentricular fontan circulation. Seminars in Thoracic and Cardiovascular Surgery. Pediatric Cardiac Surgery Annual. 14: 45-54. PMID 21444049 DOI: 10.1053/J.Pcsu.2011.01.015 |
0.338 |
|
2011 |
Estrada R, Giridharan GA, Nguyen MD, Roussel TJ, Shakeri M, Parichehreh V, Prabhu SD, Sethu P. Endothelial cell culture model for replication of physiological profiles of pressure, flow, stretch, and shear stress in vitro. Analytical Chemistry. 83: 3170-7. PMID 21413699 DOI: 10.1021/Ac2002998 |
0.374 |
|
2011 |
Slaughter MS, Giridharan GA, Tamez D, LaRose J, Sobieski MA, Sherwood L, Koenig SC. Transapical miniaturized ventricular assist device: design and initial testing. The Journal of Thoracic and Cardiovascular Surgery. 142: 668-74. PMID 21320708 DOI: 10.1016/J.Jtcvs.2011.01.011 |
0.488 |
|
2011 |
Bartoli CR, Brittian KR, Giridharan GA, Koenig SC, Hamid T, Prabhu SD. Bovine model of doxorubicin-induced cardiomyopathy. Journal of Biomedicine & Biotechnology. 2011: 758736. PMID 21253525 DOI: 10.1155/2011/758736 |
0.453 |
|
2011 |
Bartoli CR, Dowling RD, Wilson GC, Giridharan GA, Slaughter MS, Sherwood LC, Spence PA, Prabhu SD, Koenig SC. Response to Letter to the Editor: A Novel Subcutaneous Counterpulsation Device: Acute Hemodynamic Efficacy During Pharmacologically Induced Hypertension, Hypotension, and Heart Failure Artificial Organs. 35: 93-95. DOI: 10.1111/J.1525-1594.2010.01184.X |
0.421 |
|
2011 |
Kennington JR, Frankel SH, Chen J, Koenig SC, Sobieski MA, Giridharan GA, Rodefeld MD. Design Optimization and Performance Studies of an Adult Scale Viscous Impeller Pump for Powered Fontan in an Idealized Total Cavopulmonary Connection Cardiovascular Engineering and Technology. 2: 237-243. DOI: 10.1007/S13239-011-0058-2 |
0.375 |
|
2011 |
Ising M, Warren S, Sobieski MA, Slaughter MS, Koenig SC, Giridharan GA. Flow Modulation Algorithms for Continuous Flow Left Ventricular Assist Devices to Increase Vascular Pulsatility: A Computer Simulation Study Cardiovascular Engineering and Technology. 2: 90-100. DOI: 10.1007/S13239-011-0042-X |
0.496 |
|
2010 |
Giridharan GA, Nguyen MD, Estrada R, Parichehreh V, Hamid T, Ismahil MA, Prabhu SD, Sethu P. Microfluidic cardiac cell culture model (μCCCM). Analytical Chemistry. 82: 7581-7. PMID 20795703 DOI: 10.1021/Ac1012893 |
0.395 |
|
2010 |
Bartoli CR, Giridharan GA, Litwak KN, Sobieski M, Prabhu SD, Slaughter MS, Koenig SC. Hemodynamic responses to continuous versus pulsatile mechanical unloading of the failing left ventricle. Asaio Journal (American Society For Artificial Internal Organs : 1992). 56: 410-6. PMID 20613490 DOI: 10.1097/Mat.0B013E3181E7Bf3C |
0.495 |
|
2010 |
Rodefeld MD, Coats B, Fisher T, Giridharan GA, Chen J, Brown JW, Frankel SH. Cavopulmonary assist for the univentricular Fontan circulation: von Kármán viscous impeller pump. The Journal of Thoracic and Cardiovascular Surgery. 140: 529-36. PMID 20561640 DOI: 10.1016/J.Jtcvs.2010.04.037 |
0.412 |
|
2010 |
Bartoli CR, Wilson GC, Giridharan GA, Slaughter MS, Sherwood LC, Spence PA, Prabhu SD, Koenig SC. A novel subcutaneous counterpulsation device: acute hemodynamic efficacy during pharmacologically induced hypertension, hypotension, and heart failure. Artificial Organs. 34: 537-45. PMID 20560924 DOI: 10.1111/J.1525-1594.2010.01009.X |
0.505 |
|
2010 |
Slaughter MS, Ising MS, Tamez D, O'Driscoll G, Voskoboynikov N, Bartoli CR, Koenig SC, Giridharan GA. Increase in circadian variation after continuous-flow ventricular assist device implantation. The Journal of Heart and Lung Transplantation : the Official Publication of the International Society For Heart Transplantation. 29: 695-7. PMID 20207167 DOI: 10.1016/J.Healun.2009.12.006 |
0.528 |
|
2010 |
Slaughter M, Giridharan G, Aggarwal S, Sobieski M, Tamez D, LaRose J, Sherwood L, Koenig S. 294: Design and Feasibility Testing of a Miniaturized Transapical Mechanical Circulatory Support Device: MVAD The Journal of Heart and Lung Transplantation. 29: S99-S100. DOI: 10.1016/J.Healun.2009.11.306 |
0.352 |
|
2009 |
Slaughter MS, Bartoli CR, Sobieski MA, Pantalos GM, Giridharan GA, Dowling RD, Prabhu SD, Farrar DJ, Koenig SC. Intraoperative evaluation of the HeartMate II flow estimator. The Journal of Heart and Lung Transplantation : the Official Publication of the International Society For Heart Transplantation. 28: 39-43. PMID 19134529 DOI: 10.1016/J.Healun.2008.10.007 |
0.433 |
|
2009 |
Slaughter MS, Ising MS, Tamez D, O'Driscoll G, Voskoboynikov N, Bartoli CR, Koenig SC, Giridharan GA. Reappearance of a Normal Circadian Rhythm after Ventricular Assist Device Implantation Journal of Cardiac Failure. 15: S51. DOI: 10.1016/J.Cardfail.2009.06.273 |
0.408 |
|
2008 |
Koenig SC, Giridharan GA, Ewart DL, Schroeder MJ, Ionan C, Slaughter MS, Sobieski M, Pantalos GM, Dowling RD, Prabhu SD. Human, bovine and porcine systematic vascular input impedances are not equivalent: implications for device testing and xenotransplantation in heart failure. The Journal of Heart and Lung Transplantation : the Official Publication of the International Society For Heart Transplantation. 27: 1340-7. PMID 19059115 DOI: 10.1016/J.Healun.2008.08.009 |
0.461 |
|
2008 |
Koenig SC, Litwak KN, Giridharan GA, Pantalos GM, Dowling RD, Prabhu SD, Slaughter MS, Sobieski MA, Spence PA. Acute hemodynamic efficacy of a 32-ml subcutaneous counterpulsation device in a calf model of diminished cardiac function. Asaio Journal (American Society For Artificial Internal Organs : 1992). 54: 578-84. PMID 19033769 DOI: 10.1097/Mat.0B013E318186891F |
0.481 |
|
2008 |
Sharp MK, Richards CM, Gillars KJ, Giridharan G, Pantalos GM. The influence of mock circulation input impedance on valve acceleration during in vitro cardiac device testing. Asaio Journal (American Society For Artificial Internal Organs : 1992). 54: 341-6. PMID 18645349 DOI: 10.1097/Mat.0B013E31817C6Aeb |
0.435 |
|
2007 |
Pantalos GM, Giridharan G, Colyer J, Mitchell M, Speakman J, Lucci C, Johnson G, Gartner M, Koenig SC. Effect of continuous and pulsatile flow left ventricular assist on pulsatility in a pediatric animal model of left ventricular dysfunction: pilot observations. Asaio Journal (American Society For Artificial Internal Organs : 1992). 53: 385-91. PMID 17515734 DOI: 10.1097/Mat.0B013E318050D210 |
0.448 |
|
2007 |
Kaebnick BW, Giridharan GA, Koenig SC. Quantification of pulsatility as a function of vascular input impedance: an in vitro study. Asaio Journal (American Society For Artificial Internal Organs : 1992). 53: 115-21. PMID 17413547 DOI: 10.1097/01.Mat.0000250265.69542.80 |
0.437 |
|
2007 |
Travis AR, Giridharan GA, Pantalos GM, Dowling RD, Prabhu SD, Slaughter MS, Sobieski M, Undar A, Farrar DJ, Koenig SC. Vascular pulsatility in patients with a pulsatile- or continuous-flow ventricular assist device. The Journal of Thoracic and Cardiovascular Surgery. 133: 517-24. PMID 17258591 DOI: 10.1016/J.Jtcvs.2006.09.057 |
0.512 |
|
2007 |
Giridharan GA, Koenig SC, Mitchell M, Gartner M, Pantalos GM. A computer model of the pediatric circulatory system for testing pediatric assist devices. Asaio Journal (American Society For Artificial Internal Organs : 1992). 53: 74-81. PMID 17237652 DOI: 10.1097/01.Mat.0000247154.02260.30 |
0.535 |
|
2007 |
Koenig S, Giridharan G, Ionan C, Pantalos G, Dowling R, Prabhu S, Sobieski M, Slaughter M. 89: Systemic vascular input impedance in humans, calves, and pigs: Clinical implications with medical devices and xenotransplantation The Journal of Heart and Lung Transplantation. 26: S91-S92. DOI: 10.1016/J.Healun.2006.11.104 |
0.313 |
|
2007 |
Slaughter M, Sobieski M, Pantalos G, Giridharan G, Dowling R, Prabhu S, Farrar D, Koenig S. 79: Left ventricular pressure unloading with continuous and pulsatile left ventricular assist devices in advanced heart failure patients The Journal of Heart and Lung Transplantation. 26: S88. DOI: 10.1016/J.Healun.2006.11.094 |
0.504 |
|
2006 |
Giridharan GA, Skliar M. Physiological control of blood pumps using intrinsic pump parameters: a computer simulation study. Artificial Organs. 30: 301-7. PMID 16643388 DOI: 10.1111/J.1525-1594.2006.00217.X |
0.658 |
|
2006 |
Giridharan GA, Pantalos GM, Litwak KN, Spence PA, Koenig SC. Predicted hemodynamic benefits of counterpulsation therapy using a superficial surgical approach. Asaio Journal (American Society For Artificial Internal Organs : 1992). 52: 39-46. PMID 16436889 DOI: 10.1097/01.Mat.0000196522.29376.96 |
0.515 |
|
2006 |
Koenig SC, Giridharan GA, Pantalos GM, Litwak KN. ACUTE HEMODYNAMIC AND PRESSURE-VOLUME RESPONSES TO CONTINUOUS AND PULSATILE ASSIST IN DIMINISHED CARDIAC FUNCTION CALF MODEL Asaio Journal. 52: 48A. DOI: 10.1097/00002480-200603000-00206 |
0.401 |
|
2006 |
Mohan P, Giridharan G, Skliar M. COMPARSION OF AUTOMATIC CONTROL METHODS OF VENTRICULAR ASSIST DEVICES: AN IN VITRO STUDY Asaio Journal. 52: 25A. DOI: 10.1097/00002480-200603000-00115 |
0.716 |
|
2005 |
Litwak KN, Koenig SC, Cheng RC, Giridharan GA, Gillars KJ, Pantalos GM. Ascending aorta outflow graft location and pulsatile ventricular assist provide optimal hemodynamic support in an adult mock circulation. Artificial Organs. 29: 629-35. PMID 16048479 DOI: 10.1111/J.1525-1594.2005.29100.X |
0.437 |
|
2005 |
Giridharan G, Pantalos G, Koenig S, Gillars K, Skliar M. Achieving physiologic perfusion with ventricular assist devices: Comparison of control strategies Proceedings of the American Control Conference. 6: 3823-3828. |
0.689 |
|
2004 |
Giridharan GA, Ewert DL, Pantalos GM, Gillars KJ, Litwak KN, Gray LA, Koenig SC. Left ventricular and myocardial perfusion responses to volume unloading and afterload reduction in a computer simulation. Asaio Journal (American Society For Artificial Internal Organs : 1992). 50: 512-8. PMID 15497394 DOI: 10.1097/01.Mat.0000136513.21369.75 |
0.545 |
|
2004 |
Giridharan GA, Pantalos GM, Gillars KJ, Koenig SC, Skliar M. Physiologic control of rotary blood pumps: an in vitro study. Asaio Journal (American Society For Artificial Internal Organs : 1992). 50: 403-9. PMID 15497377 DOI: 10.1097/01.Mat.0000136652.78197.58 |
0.708 |
|
2004 |
Pantalos GM, Koenig SC, Gillars KJ, Giridharan GA, Ewert DL. Characterization of an adult mock circulation for testing cardiac support devices. Asaio Journal (American Society For Artificial Internal Organs : 1992). 50: 37-46. PMID 14763490 DOI: 10.1097/01.Mat.0000104818.70726.E6 |
0.543 |
|
2004 |
Glower JS, Ewert DE, Nyblom H, Giridharan GA, Koenig S. A Simulation Study On The Effect Of The Left Ventrical Ejection Profile Asaio Journal. 50: 150. DOI: 10.1097/00002480-200403000-00158 |
0.317 |
|
2004 |
Giridharan GA, Glower J, Ewert DL, Pantalos CM, Cillars KJ, Litwak KN, Koenig SC. CONTROL ALGORITHMS FOR AN ARTIFICIAL VASCULATURE DEVICE Asaio Journal. 50: 149. DOI: 10.1097/00002480-200403000-00153 |
0.354 |
|
2004 |
Cheng RC, Giridharan GA, Gillars KJ, Pantalos GM, Koenig SC, Litwak KN. AORTIC BLOOD FLOW WITH PULSATILE OR CONTINUOUS VADs IS A FUNCTION OF OUTFLOW GRAFT LOCATION NOT PUMP TYPE Asaio Journal. 50: 139. DOI: 10.1097/00002480-200403000-00114 |
0.346 |
|
2004 |
Koenig SC, Pantalos GM, Litwak KN, Gillars KJ, Giridharan GA, Maguire M, Spence PA. Hemodynamic and left ventricular pressure-volume responses to counterpulsation in mock circulation and acute large animal models Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 26: 3761-3764. |
0.446 |
|
2004 |
Glower JS, Cheng RC, Giridharan GA, Gillars KJ, Pantalos GM, Litwak KN, Ewert DL, Koenig SC. In vitro evaluation of control strategies for an artificial vasculature device Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 26: 3773-3776. |
0.38 |
|
2003 |
Giridharan GA, Skliar M. Control strategy for maintaining physiological perfusion with rotary blood pumps. Artificial Organs. 27: 639-48. PMID 12823419 DOI: 10.1046/J.1525-1594.2003.07089.X |
0.705 |
|
2003 |
Giridharan GA, Ewert DI, Gillars KJ, Pantalos GM, Litwak KN, Gray LA, Koenig SC. CONTROL STRATEGY FOR AN ARTIFICIAL VASCULAR UNLOADING DEVICE Asaio Journal. 49: 153. DOI: 10.1097/00002480-200303000-00052 |
0.378 |
|
2003 |
Giridharan GA, Skliar M. Physiological Control of Blood Pumps Without Implantable Sensors Proceedings of the American Control Conference. 1: 471-476. |
0.631 |
|
2002 |
Giridharan GA, Skliar M. Nonlinear controller for ventricular assist devices. Artificial Organs. 26: 980-4. PMID 12406156 DOI: 10.1046/J.1525-1594.2002.07136.X |
0.703 |
|
2002 |
Giridharan GA, Skliar M, Olsen DB, Pantalos GM. Modeling and control of a brushless DC axial flow ventricular assist device. Asaio Journal (American Society For Artificial Internal Organs : 1992). 48: 272-89. PMID 12059002 DOI: 10.1097/00002480-200205000-00013 |
0.704 |
|
2001 |
Giridharan GA, Skliar M. Modeling of the human circulatory system with an axial flow ventricular assist device Proceedings of the American Control Conference. 5: 3801-3806. |
0.675 |
|
Show low-probability matches. |