Jaydev K. Dave, Ph.D. - Publications

Affiliations: 
2012 Biomedical Engineering Drexel University, Philadelphia, PA, United States 
Area:
Biomedical Engineering, Radiology, Acoustics Physics

58 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2024 Esposito C, Machado P, McDonald ME, Savage MP, Fischman D, Mehrotra P, Cohen IS, Ruggiero N, Walinsky P, Vishnevsky A, Dickie K, Davis M, Forsberg F, Dave JK. Evaluation of Intracardiac Pressures Using Subharmonic-aided Pressure Estimation with Sonazoid Microbubbles. Radiology. Cardiothoracic Imaging. 6: e230153. PMID 38358329 DOI: 10.1148/ryct.230153  0.564
2024 Esposito C, Tzan K, Machado P, Forsberg F, Dave JK. The Effect of Mixing Iodinated Contrast Media and Ultrasound Contrast Agents on Subharmonic Signals. Ultrasonic Imaging. 1617346241227971. PMID 38318708 DOI: 10.1177/01617346241227971  0.568
2022 Esposito C, Machado P, McDonald ME, Savage MP, Fischman D, Mehrotra P, Cohen IS, Ruggiero N, Walinsky P, Vishnevsky A, Dickie K, Davis M, Forsberg F, Dave JK. Noninvasive Evaluation of Cardiac Chamber Pressures Using Subharmonic-Aided Pressure Estimation With Definity Microbubbles. Jacc. Cardiovascular Imaging. PMID 36648035 DOI: 10.1016/j.jcmg.2022.09.013  0.575
2022 Esposito C, Machado P, Cohen IS, Mehrotra P, Savage M, Fischman D, Davis M, Ruggiero N, Walinsky P, McDonald ME, Dickie K, Forsberg F, Dave JK. Comparing Central Aortic Pressures Obtained Using a SphygmoCor Device to Pressures Obtained Using a Pressure Catheter. American Journal of Hypertension. PMID 35079778 DOI: 10.1093/ajh/hpac010  0.539
2021 van Hoeve W, de Vargas Serrano M, Te Winkel L, Forsberg F, Dave JK, Sarkar K, Wessner CE, Eisenbrey JR. Improved Sensitivity of Ultrasound-Based Subharmonic Aided Pressure Estimation Using Monodisperse Microbubbles. Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine. PMID 34724241 DOI: 10.1002/jum.15861  0.559
2021 Esposito C, Dickie K, Forsberg F, Dave JK. Developing an Interface and Investigating Optimal Parameters for Real-Time Intracardiac Subharmonic-Aided Pressure Estimation. Ieee Transactions On Ultrasonics, Ferroelectrics, and Frequency Control. 68: 579-585. PMID 32784134 DOI: 10.1109/Tuffc.2020.3016264  0.605
2020 Trunz LM, Eschelman DJ, Gonsalves CF, Adamo RD, Dave JK. Investigation of Radiation Dose Estimates and Image Quality Between Commercially Available Interventional Fluoroscopy Systems for Fluoroscopically Guided Interventional Procedures. Academic Radiology. PMID 32224035 DOI: 10.1016/J.Acra.2020.02.024  0.305
2019 Walz-Flannigan A, Weiser J, Goode AR, Junck K, Tarbox L, Dave JK, Clunie DA, McColl RW, Langer SG. Summary of the AAPM Task Group 248 Report: Interoperability Assessment for the Commissioning of Medical Imaging Acquisition Systems. Medical Physics. PMID 31055845 DOI: 10.1002/Mp.13571  0.351
2019 Trunz L, Eschelman D, Gonsalves C, Adamo R, Dave J. 03:36 PM Abstract No. 290 Phantom and in vivo comparison of radiation dose estimates and image quality between state-of-the-art interventional fluoroscopy systems Journal of Vascular and Interventional Radiology. 30: S129-S130. DOI: 10.1016/J.Jvir.2018.12.355  0.313
2018 Dave JK, Jones AK, Fisher R, Hulme K, Rill L, Zamora D, Woodward A, Brady S, MacDougall RD, Goldman L, Lang S, Peck D, Apgar B, Shepard SJ, Uzenoff R, et al. Current State of Practice Regarding Digital Radiography Exposure Indicators and Deviation Indices: Report of AAPM Imaging Physics Committee Task Group 232. Medical Physics. PMID 30255505 DOI: 10.1002/Mp.13212  0.307
2017 Dave JK, Mc Donald ME, Mehrotra P, Kohut AR, Eisenbrey JR, Forsberg F. Recent technological advancements in cardiac ultrasound imaging. Ultrasonics. 84: 329-340. PMID 29223692 DOI: 10.1016/J.Ultras.2017.11.013  0.549
2017 Dave JK, Kulkarni SV, Pangaonkar PP, Stanczak M, McDonald ME, Cohen IS, Mehrotra P, Savage MP, Walinsky P, Ruggiero NJ, Fischman DL, Ogilby D, VanWhy C, Lombardi M, Forsberg F. Non-Invasive Intra-cardiac Pressure Measurements Using Subharmonic-Aided Pressure Estimation: Proof of Concept in Humans. Ultrasound in Medicine & Biology. PMID 28807449 DOI: 10.1016/J.Ultrasmedbio.2017.07.009  0.623
2017 Halldorsdottir VG, Dave JK, Marshall A, Forsberg AI, Fox TB, Eisenbrey JR, Machado P, Liu JB, Merton DA, Forsberg F. Subharmonic-Aided Pressure Estimation for Monitoring Interstitial Fluid Pressure in Tumors: Calibration and Treatment with Paclitaxel in Breast Cancer Xenografts. Ultrasound in Medicine & Biology. PMID 28433436 DOI: 10.1016/J.Ultrasmedbio.2017.02.011  0.624
2017 Forsberg MA, Eschelman DJ, Talreja P, Dave JK. Do quantitative metrics derived from standard fluoroscopy phantoms used for quality control assess vendor-specific advancements in interventional fluoroscopy systems? Proceedings of Spie. 10136: 1013619. DOI: 10.1117/12.2254561  0.338
2017 Forsberg M, Eschelman D, Dave J. On the use of quantitative metrics from clinical images for image quality evaluation in fluoroscopically guided interventional procedures Journal of Vascular and Interventional Radiology. 28: S194-S195. DOI: 10.1016/J.Jvir.2016.12.1078  0.354
2016 Finley C, Dave J. SU-G-IeP3-11: On the Utility of Pixel Variance to Characterize Noise for Image Receptors of Digital Radiography Systems. Medical Physics. 43: 3669. PMID 28048237 DOI: 10.1118/1.4957060  0.314
2016 Finley C, Dave J. TU-FG-209-04: Testing of Digital Image Receptors Using AAPM TG-150's Draft Recommendations - Investigating the Impact of Different Processing Parameters. Medical Physics. 43: 3761. PMID 28047963 DOI: 10.1118/1.4957574  0.317
2016 Gupta I, Eisenbrey J, Stanczak M, Sridharan A, Dave JK, Liu JB, Hazard C, Wang X, Wang P, Li H, Wallace K, Forsberg F. Effect of Pulse Shaping on Subharmonic Aided Pressure Estimation In Vitro and In Vivo. Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine. PMID 27943411 DOI: 10.7863/Ultra.15.11106  0.626
2016 Gupta A, Forsberg MA, Dulin K, Jaffe S, Dave JK, Halldorsdottir VG, Marshall A, Forsberg AI, Eisenbrey JR, Machado P, Fox TB, Liu JB, Forsberg F. Comparing Quantitative Immunohistochemical Markers of Angiogenesis to Contrast-Enhanced Subharmonic Imaging. Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine. PMID 27388814 DOI: 10.7863/Ultra.15.05024  0.55
2016 Sridharan A, Eisenbrey JR, Dave JK, Forsberg F. Quantitative Nonlinear Contrast-Enhanced Ultrasound of the Breast. Ajr. American Journal of Roentgenology. 1-8. PMID 27223688 DOI: 10.2214/Ajr.16.16315  0.52
2016 Eisenbrey JR, Dave JK, Forsberg F. Recent technological advancements in breast ultrasound. Ultrasonics. 70: 183-190. PMID 27179143 DOI: 10.1016/J.Ultras.2016.04.021  0.535
2016 Dave JK, Eschelman DJ, Wasserman JR, Gonsalves CF, Gingold EL. A Phantom Study and a Retrospective Clinical Analysis to Investigate the Impact of a New Image Processing Technology on Radiation Dose and Image Quality during Hepatic Embolization. Journal of Vascular and Interventional Radiology : Jvir. PMID 26948994 DOI: 10.1016/J.Jvir.2016.01.131  0.348
2015 Dahibawkar M, Forsberg MA, Gupta A, Jaffe S, Dulin K, Eisenbrey JR, Halldorsdottir VG, Forsberg AI, Dave JK, Marshall A, Machado P, Fox TB, Liu JB, Forsberg F. High and low frequency subharmonic imaging of angiogenesis in a murine breast cancer model. Ultrasonics. 62: 50-5. PMID 25979676 DOI: 10.1016/J.Ultras.2015.04.012  0.549
2015 Halldorsdottir V, Marshall A, Dave J, Forsberg A, Machado P, Fox T, Liu J, Forsberg F. 2090329 Subharmonic Pressure Estimation in Breast Tumors: An In Vivo Calibration Study Ultrasound in Medicine & Biology. 41: S79-S80. DOI: 10.1016/J.Ultrasmedbio.2014.12.332  0.572
2015 Gupta A, Forsberg MA, Dulin K, Jaffe S, Dave JK, Halldorsdottir VG, Marshall A, Forsberg AI, Machado P, Fox T, Liu J, Forsberg F. 2085423 Comparing Quantitative Immunohistochemical Markers of Angiogenesis to Subharmonic Contrast Imaging Ultrasound in Medicine & Biology. 41: S77. DOI: 10.1016/J.Ultrasmedbio.2014.12.326  0.545
2014 Halldorsdottir VG, Dave JK, Eisenbrey JR, Machado P, Zhao H, Liu JB, Merton DA, Forsberg F. Subharmonic aided pressure estimation for monitoring interstitial fluid pressure in tumours--in vitro and in vivo proof of concept. Ultrasonics. 54: 1938-44. PMID 24856899 DOI: 10.1016/J.Ultras.2014.04.022  0.621
2014 Gingold E, Dave J. SU-E-I-33: Initial Evaluation of Model-Based Iterative CT Reconstruction Using Standard Image Quality Phantoms Medical Physics. 41: 137-137. DOI: 10.1118/1.4887981  0.344
2014 Gupta A, Forsberg MA, Dulin K, Jaffe S, Dave JK, Dahibawkar M, Halldorsdottir VG, Marshall A, Forsberg AI, Machado P, Fox TB, Liu JB, Forsberg F. Comparing subharmonic imaging and immunohistochemical markers of angiogenesis Ieee International Ultrasonics Symposium, Ius. 1156-1159. DOI: 10.1109/ULTSYM.2014.0284  0.465
2013 Sridharan A, Eisenbrey JR, Liu JB, Machado P, Halldorsdottir VG, Dave JK, Zhao H, He Y, Park S, Dianis S, Wallace K, Thomenius KE, Forsberg F. Perfusion estimation using contrast-enhanced 3-dimensional subharmonic ultrasound imaging: an in vivo study. Investigative Radiology. 48: 654-60. PMID 23695085 DOI: 10.1097/Rli.0B013E3182925160  0.566
2013 Eisenbrey JR, Dave JK, Halldorsdottir VG, Merton DA, Miller C, Gonzalez JM, Machado P, Park S, Dianis S, Chalek CL, Kim CE, Baliff JP, Thomenius KE, Brown DB, Navarro V, et al. Chronic liver disease: noninvasive subharmonic aided pressure estimation of hepatic venous pressure gradient. Radiology. 268: 581-8. PMID 23525208 DOI: 10.1148/Radiol.13121769  0.576
2013 Dave JK, Halldorsdottir VG, Eisenbrey JR, Merton DA, Liu JB, Machado P, Zhao H, Park S, Dianis S, Chalek CL, Thomenius KE, Brown DB, Forsberg F. On the implementation of an automated acoustic output optimization algorithm for subharmonic aided pressure estimation. Ultrasonics. 53: 880-8. PMID 23347593 DOI: 10.1016/J.Ultras.2012.12.010  0.607
2012 Dave J, Gingold E, Yorkston J, Bercha I, Goldman L, Walz‐flannigan A, Willis CE. SU‐E‐I‐103: Detecting Anomalous Pixels and Correlated Artifacts in Digital Detectors from Flat‐Field Images Medical Physics. 39: 3648-3649. PMID 28517660 DOI: 10.1118/1.4734820  0.382
2012 Dave J, Gingold E, Yorkston J, Bercha I, Goldman L, Walz‐Flannigan A, Willis C. SU‐E‐I‐101: Initial Implementation and Evaluation of AAPM TG‐150 Draft Image Receptor Non‐Uniformity Testing Recommendations Medical Physics. 39: 3648-3648. PMID 28517653 DOI: 10.1118/1.4734818  0.37
2012 Dave JK, Liu JB, Halldorsdottir VG, Eisenbrey JR, Merton DA, Machado P, Zhao H, Altemus J, Needleman L, Brown DB, Forsberg F. Acute portal hypertension models in dogs: low- and high-flow approaches. Comparative Medicine. 62: 419-26. PMID 23114046  0.448
2012 Dave JK, Halldorsdottir VG, Eisenbrey JR, Merton DA, Liu JB, Zhou JH, Wang HK, Park S, Dianis S, Chalek CL, Lin F, Thomenius KE, Brown DB, Forsberg F. Investigating the efficacy of subharmonic aided pressure estimation for portal vein pressures and portal hypertension monitoring. Ultrasound in Medicine & Biology. 38: 1784-98. PMID 22920550 DOI: 10.1016/J.Ultrasmedbio.2012.06.013  0.611
2012 Dave JK, Halldorsdottir VG, Eisenbrey JR, Forsberg F. Processing of subharmonic signals from ultrasound contrast agents to determine ambient pressures. Ultrasonic Imaging. 34: 81-92. PMID 22724314 DOI: 10.1177/016173461203400202  0.601
2012 Dave JK, Halldorsdottir VG, Eisenbrey JR, Raichlen JS, Liu JB, McDonald ME, Dickie K, Wang S, Leung C, Forsberg F. Subharmonic microbubble emissions for noninvasively tracking right ventricular pressures. American Journal of Physiology. Heart and Circulatory Physiology. 303: H126-32. PMID 22561300 DOI: 10.1152/Ajpheart.00560.2011  0.618
2012 Eisenbrey JR, Sridharan A, Machado P, Zhao H, Halldorsdottir VG, Dave JK, Liu JB, Park S, Dianis S, Wallace K, Thomenius KE, Forsberg F. Three-dimensional subharmonic ultrasound imaging in vitro and in vivo. Academic Radiology. 19: 732-9. PMID 22464198 DOI: 10.1016/J.Acra.2012.02.015  0.566
2012 Dave JK, Halldorsdottir VG, Eisenbrey JR, Raichlen JS, Liu JB, McDonald ME, Dickie K, Wang S, Leung C, Forsberg F. Noninvasive LV pressure estimation using subharmonic emissions from microbubbles. Jacc. Cardiovascular Imaging. 5: 87-92. PMID 22239898 DOI: 10.1016/J.Jcmg.2011.08.017  0.598
2012 Dave JK, Halldorsdottir VG, Eisenbrey JR, Raichlen JS, Liu JB, McDonald ME, Dickie K, Wang S, Leung C, Forsberg F. Noninvasive right ventricular pressure estimation in vivo using the subharmonic emissions from ultrasound contrast agents Ieee International Ultrasonics Symposium, Ius. 1114-1117. DOI: 10.1109/ULTSYM.2012.0277  0.582
2012 Dave JK, Halldorsdottir VG, Eisenbrey JR, Merton DA, Liu JB, Zhou JH, Wang HK, Park S, Dianis S, Chalek CL, Lin F, Thomenius KE, Brown DB, Forsberg F. On the utility of subharmonic microbubble signals to detect portal hypertension Ieee International Ultrasonics Symposium, Ius. 655-658. DOI: 10.1109/ULTSYM.2012.0163  0.547
2012 Eisenbrey J, Dave J, Halldorsdottir V, Merton D, Gonzalez J, Miller C, Machado P, Park S, Dianis S, Chalek C, Thomenius K, Brown D, Navarro V, Forsberg F. Abstract No. 229: Noninvasive measurement of portal hypertension using a novel contrast-enhanced ultrasound technique Journal of Vascular and Interventional Radiology. 23: S94. DOI: 10.1016/J.Jvir.2011.12.279  0.518
2011 Dave JK, Halldorsdottir VG, Eisenbrey JR, Liu JB, McDonald ME, Dickie K, Leung C, Forsberg F. Noninvasive estimation of dynamic pressures in vitro and in vivo using the subharmonic response from microbubbles. Ieee Transactions On Ultrasonics, Ferroelectrics, and Frequency Control. 58: 2056-66. PMID 21989870 DOI: 10.1109/Tuffc.2011.2056  0.634
2011 Halldorsdottir VG, Dave JK, Leodore LM, Eisenbrey JR, Park S, Hall AL, Thomenius K, Forsberg F. Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions. Ultrasonic Imaging. 33: 153-64. PMID 21842580 DOI: 10.1177/016173461103300301  0.632
2011 Eisenbrey JR, Dave JK, Halldorsdottir VG, Merton DA, Machado P, Liu JB, Miller C, Gonzalez JM, Park S, Dianis S, Chalek CL, Thomenius KE, Brown DB, Navarro V, Forsberg F. Simultaneous grayscale and subharmonic ultrasound imaging on a modified commercial scanner. Ultrasonics. 51: 890-7. PMID 21621239 DOI: 10.1016/J.Ultras.2011.05.003  0.575
2011 Eisenbrey JR, Joshi N, Dave JK, Forsberg F. Assessing algorithms for defining vascular architecture in subharmonic images of breast lesions. Physics in Medicine and Biology. 56: 919-30. PMID 21248388 DOI: 10.1088/0031-9155/56/4/003  0.534
2011 Eisenbrey JR, Dave JK, Merton DA, Palazzo JP, Hall AL, Forsberg F. Parametric imaging using subharmonic signals from ultrasound contrast agents in patients with breast lesions. Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine. 30: 85-92. PMID 21193708 DOI: 10.7863/Jum.2011.30.1.85  0.548
2011 Eisenbrey JR, Dave JK, Halldorsdottir VG, Sridharan A, Park S, Dianis S, Merton DA, MacHado P, Liu JBB, Gonzalez JM, Miller C, Thomenius KE, Brown DB, Navarro V, Forsberg F. Simultaneous B-mode/subharmonic imaging and 3D subharmonic imaging on a modified commercial ultrasound scanner Ieee International Ultrasonics Symposium, Ius. 624-627. DOI: 10.1109/ULTSYM.2011.0151  0.521
2011 Eisenbrey JR, Dave JK, Halldorsdottir VG, Merton DA, Miller C, Gonzalez JM, Machado P, Park S, Dianis S, Chalek CL, Thomenius KE, Brown DB, Navarro V, Forsberg F. Subharmonic aided pressure estimation in patients with suspected portal hypertension Ieee International Ultrasonics Symposium, Ius. 620-623. DOI: 10.1109/ULTSYM.2011.0150  0.556
2010 Dave JK, Forsberg F, Fernandes S, Piccoli CW, Fox TB, Merton DA, Leodore LM, Hall AL. Static and dynamic cumulative maximum intensity display mode for subharmonic breast imaging: a comparative study with mammographic and conventional ultrasound techniques. Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine. 29: 1177-85. PMID 20660451 DOI: 10.7863/Jum.2010.29.8.1177  0.561
2010 Eisenbrey JR, Dave JK, Merton DA, Palazzo JP, Hall AL, Forsberg F. Breast lesion characterization by parametric imaging of subharmonic signalsfrom ultrasound contrast agents Proceedings - Ieee Ultrasonics Symposium. 790-793. DOI: 10.1109/ULTSYM.2010.5935784  0.51
2010 Dave J, Halldorsdottir V, Eisenbrey J, Liu JB, Lin F, Zhou JH, Wang HK, Thomenius K, Forsberg F. In vivo subharmonic pressure estimation of portal hypertension in canines Proceedings - Ieee Ultrasonics Symposium. 778-781. DOI: 10.1109/ULTSYM.2010.5935782  0.565
2009 Dave JK, Forsberg F. Novel automated motion compensation technique for producing cumulative maximum intensity subharmonic images. Ultrasound in Medicine & Biology. 35: 1555-63. PMID 19616359 DOI: 10.1016/J.Ultrasmedbio.2009.04.016  0.559
2009 Gingold E, Dave J. SU-FF-I-118: Assessment of the Spatial Resolution of Digital Imaging Systems Using a Star Pattern Medical Physics. 36: 2462-2462. DOI: 10.1118/1.3181239  0.335
2009 Dave J, Gingold E. SU-FF-I-83: Quantitative Analysis of Low Contrast Image Quality in Fluoroscopic Systems Medical Physics. 36: 2453-2453. DOI: 10.1118/1.3181203  0.38
2008 Gingold E, Dave J. SU-GG-I-11: Dose and Image Quality Evaluation of a Mobile CT Scanner for Head and Neck Imaging Medical Physics. 35: 2645-2645. DOI: 10.1118/1.2961410  0.359
2008 Forsberg F, Dave J, Halldorsdottir VG, Leodore LM, Lin F, Hall AL, Thomenius K. Applying real-time noninvasive pressure estimation obtained from subharmonic contrast microbubble signals Proceedings - Ieee Ultrasonics Symposium. 1694-1697. DOI: 10.1109/ULTSYM.2008.0414  0.601
2008 Dave J, Forsberg F, Merton DA, Fernandes S, Fox TB, Leodore LM, Hall AL. Image processing algorithms for cumulative maximum intensity subharmonic ultrasound imaging: A comparative study in the breast Proceedings - Ieee Ultrasonics Symposium. 1655-1658. DOI: 10.1109/ULTSYM.2008.0404  0.526
Show low-probability matches.