Alireza Kargar, Ph.D. - Publications

Affiliations: 
2009 Department of Mechanical and Nuclear Engineering Kansas State University, Manhattan, KS, United States 
Area:
Nuclear Engineering

31 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2020 Kargar A, Hong H, Tower J, Gueorguiev A, Kim H, Cirignano L, Christian JF, Squillante MR, Shah K. LiInSe2 for Semiconductor Neutron Detectors Frontiers in Physics. 8. DOI: 10.3389/fphy.2020.00078  0.413
2020 Kim H, Ogorodnik Y, Kargar A, Cirignano L, Thrall CL, Koehler W, O'Neal SP, He Z, Swanberg E, Payne SA, Squillante MR, Shah K. Thallium Bromide Gamma-Ray Spectrometers and Pixel Arrays Frontiers in Physics. 8. DOI: 10.3389/fphy.2020.00055  0.365
2013 Kim H, Cirignano L, Kargar A, Churilov A, Ciampi G, Ogorodnik Y, Higgins W, Kim S, Olschner F, Shah K. Long Term Stability of Thallium Bromide Gamma-Ray Spectrometers Ieee Transactions On Nuclear Science. 60: 1219-1224. DOI: 10.1109/Tns.2013.2251658  0.439
2012 Cirignano L, Kim H, Kargar A, Churilov AV, Ciampi G, Higgins W, Kim S, Barber B, Haston K, Shah K. Application of TlBr to nuclear medicine imaging Proceedings of Spie. 8508: 850803. DOI: 10.1117/12.961447  0.412
2012 Kim H, Kargar A, Cirignano L, Churilov A, Ciampi G, Higgins W, Olschner F, Shah K. Recent Progress in Thallium Bromide Gamma-Ray Spectrometer Development Ieee Transactions On Nuclear Science. 59: 243-248. DOI: 10.1109/Tns.2011.2173503  0.508
2012 Kargar A, Tower JP, Hong H, Cirignano LJ, Kim H, Beck PR, Conway AM, Drury OB, Voss LF, Graff RT, Nelson AJ, Nikolic RJ, Payne SA, Badikov V, Shah K. PbGa2Se4 semiconductor for gamma-ray detection Ieee Nuclear Science Symposium Conference Record. 4258-4261. DOI: 10.1109/NSSMIC.2012.6551971  0.332
2011 Kargar A, Ariesanti E, McGregor DS. A Comparison Between Spectroscopic Performance of HgI2and CdZnTe Frisch Collar Detectors Nuclear Technology. 175: 131-137. DOI: 10.13182/Nt11-A12281  0.782
2011 Ariesanti E, Kargar A, McGregor DS. Mercuric Iodide Crystal Growth and Frisch Collar Detector Fabrication Nuclear Technology. 175: 124-130. DOI: 10.13182/Nt11-A12280  0.775
2011 Kargar A, Tower J, Hong H, Cirignano L, Higgins W, Shah K. Lithium and boron based semiconductors for thermal neutron counting Proceedings of Spie. 8142. DOI: 10.1117/12.899363  0.484
2011 Sun K, Kargar A, Park N, Madsen KN, Naughton PW, Bright T, Jing Y, Wang D. Compound semiconductor nanowire solar cells Ieee Journal On Selected Topics in Quantum Electronics. 17: 1033-1049. DOI: 10.1109/Jstqe.2010.2090342  0.309
2011 Kargar A, Ariesanti E, James S, McGregor D. Charge collection efficiency characterization of a HgI2 Frisch collar spectrometer with collimated high energy gamma rays Nuclear Instruments and Methods in Physics Research Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 652: 186-192. DOI: 10.1016/J.Nima.2010.08.057  0.801
2010 Kim H, Cirignano L, Churilov A, Ciampi G, Kargar A, Higgins W, O'Dougherty P, Kim S, Squillante MR, Shah K. Continued development of room temperature semiconductor nuclear detectors Proceedings of Spie. 7806: 780604. DOI: 10.1117/12.864147  0.418
2010 Ugorowski P, Ariesanti A, McGregor DS, Kargar A. Compact, inexpensive, high-energy-resolution, room-temperature-operated, semiconductor gamma-ray detectors for isotope identification 2010 Ieee International Conference On Technologies For Homeland Security, Hst 2010. 385-390. DOI: 10.1109/THS.2010.5654940  0.51
2010 Ariesanti E, Kargar A, McGregor D. Fabrication and spectroscopy results of mercuric iodide Frisch collar detectors Nuclear Instruments and Methods in Physics Research Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 624: 656-661. DOI: 10.1016/J.Nima.2010.09.075  0.782
2010 Kargar A, Harrison MJ, Brooks AC, McGregor DS. Characterization of charge carrier collection in a CdZnTe Frisch collar detector with a highly collimated 137Cs source Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 620: 270-278. DOI: 10.1016/J.Nima.2010.02.104  0.779
2010 Nelson KA, Edwards N, Harrison MJ, Kargar A, McNeil WJ, Rojeski RA, McGregor DS. Investigation of CdZnTe and LiNbO3 as electro-optic neutron detectors Nuclear Instruments and Methods in Physics Research Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 620: 363-367. DOI: 10.1016/J.Nima.2009.12.042  0.741
2009 Kargar A, Brooks AC, Harrison MJ, Chen H, Awadalla S, Bindley G, Redden B, McGregor DS. Uniformity of charge collection efficiency in Frisch collar spectrometer with THM grown CdZnTe crystals Proceedings of Spie - the International Society For Optical Engineering. 7449. DOI: 10.1117/12.826422  0.755
2009 Kargar A, Brooks AC, Harrison MJ, Kohman KT, Lowell RB, Keyes RC, Chen H, Bindley G, McGregor DS. The effect of the dielectric layer thickness on spectral performance of cdznte frisch collar gamma ray spectrometers Ieee Transactions On Nuclear Science. 56: 824-831. DOI: 10.1109/Tns.2009.2017193  0.71
2009 Harrison MJ, Kargar A, Brooks AC, Carpenter KH, McGregor DS. Improved Techniques for the Fabrication of Frisch Collar CdZnTe Gamma Ray Spectrometers Ieee Transactions On Nuclear Science. 56: 1671-1676. DOI: 10.1109/Tns.2009.2016660  0.7
2009 Kargar A, Brooks AC, Harrison MJ, Chen H, Awadalla S, Bindley G, McGregor DS. Effect of crystal length on CdZnTe Frisch collar device performance Ieee Nuclear Science Symposium Conference Record. 2017-2022. DOI: 10.1109/NSSMIC.2009.5402138  0.452
2009 Ugorowski PB, Kargar A, McGregor DS. Pulse height linearity of CdZnTe Ieee Nuclear Science Symposium Conference Record. 2023-2031. DOI: 10.1109/NSSMIC.2009.5402122  0.662
2008 Kargar A, Brooks AC, Kohman KT, Lowell RB, Keyes RC, Chen H, Awadalla S, Bindley G, McGregor DS. The final surface treatment effect on performance of CdZnTe frisch collar gamma ray detectors Proceedings of Spie - the International Society For Optical Engineering. 7079. DOI: 10.1117/12.795366  0.661
2008 Cui Y, Bolotnikov A, Camarda G, Hossain A, James RB, Geronimo GD, Fried J, O'Connor P, Kargar A, Harrison MJ, McGregor DS. Hand-Held Gamma-Ray Spectrometer Based on High-Efficiency Frisch-Ring CdZnTe Detectors Ieee Transactions On Nuclear Science. 55: 2765-2769. DOI: 10.1109/Tns.2008.2004803  0.754
2007 Kargar A, Lowell RB, Harrison MJ, McGregor DS. The crystal geometry and the aspect ratio effects on spectral performance of CdZnTe Frisch collar device Proceedings of Spie - the International Society For Optical Engineering. 6706. DOI: 10.1117/12.740472  0.75
2007 Mandal KC, Kang SH, Choi M, Kargar A, Harrison MJ, McGregor DS, Bolotnikov AE, Carini GA, Camarda GC, James RB. Characterization of low-defect Cd0.9Zn0.1Te and CdTe crystals for high-performance frisch collar detectors Ieee Transactions On Nuclear Science. 54: 802-806. DOI: 10.1109/Tns.2007.902371  0.754
2007 Cui Y, Bolotnikov A, Camarda G, Hossain A, James RB, De Geronimo G, Fried J, O'Connor P, Kargar A, Harrison MJ, McGregor DS, Carini GA. Hand-held gamma-ray spectrometer based on high-efficiency frisch-ring CdZnTe detectors Ieee Nuclear Science Symposium Conference Record. 2: 945-948. DOI: 10.1109/NSSMIC.2007.4437174  0.363
2007 Harrison MJ, Kargar A, Brooks AC, McGregor DS. Improved techniques for the fabrication of Frisch collar CdZnTe gamma ray spectrometers Ieee Nuclear Science Symposium Conference Record. 3: 1816-1821. DOI: 10.1109/NSSMIC.2007.4436511  0.31
2007 McGregor DS, Bellinger SL, Bruno D, Cowley SA, Dunn WL, Elazegui M, Kargar A, McNeil WJ, Oyenan H, Patterson E, Shultis JK, Singh G, Solomon CJ, Unruh TC. Wireless neutron and gamma ray detector modules for dosimetry and remote monitoring Ieee Nuclear Science Symposium Conference Record. 1: 808-812. DOI: 10.1109/NSSMIC.2007.4436451  0.773
2007 Harrison MJ, Kargar A, McGregor DS. Charge collection characteristics of Frisch collar CdZnTe gamma-ray spectrometers Nuclear Instruments and Methods in Physics Research Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 579: 134-137. DOI: 10.1016/J.Nima.2007.04.128  0.778
2006 Kargar A, Jones AM, McNeil WJ, Harrison MJ, McGregor DS. Angular response of a W-collimated room-temperature-operated CdZnTe Frisch collar spectrometer Nuclear Instruments and Methods in Physics Research Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 562: 262-271. DOI: 10.1016/J.Nima.2006.02.001  0.798
2006 Kargar A, Jones AM, McNeil WJ, Harrison MJ, McGregor DS. CdZnTe Frisch collar detectors for γ-ray spectroscopy Nuclear Instruments and Methods in Physics Research Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 558: 497-503. DOI: 10.1016/J.Nima.2005.11.211  0.796
Show low-probability matches.