Year |
Citation |
Score |
2022 |
Majedy M, Das N, Johansson J, Saager R. Influence of optical aberrations on depth-specific spatial frequency domain techniques. Journal of Biomedical Optics. 27. PMID 36358008 DOI: 10.1117/1.JBO.27.11.116003 |
0.419 |
|
2022 |
Afshari A, Saager RB, Burgos D, Vogt WC, Wang J, Mendoza G, Weininger S, Sung KB, Durkin AJ, Pfefer TJ. Evaluation of the robustness of cerebral oximetry to variations in skin pigmentation using a tissue-simulating phantom. Biomedical Optics Express. 13: 2909-2928. PMID 35774336 DOI: 10.1364/BOE.454020 |
0.572 |
|
2020 |
Belcastro L, Jonasson H, Strömberg T, Saager RB. Handheld multispectral imager for quantitative skin assessment in low-resource settings. Journal of Biomedical Optics. 25: 1-12. PMID 32755076 DOI: 10.1117/1.Jbo.25.8.082702 |
0.485 |
|
2020 |
Applegate M, Karrobi K, Angelo J, Austin W, Tabassum S, Aguénounon E, Tilbury K, Saager R, Gioux S, Roblyer D. OpenSFDI: an open-source guide for constructing a spatial frequency domain imaging system. Journal of Biomedical Optics. 25: 1-13. PMID 31925946 DOI: 10.1117/1.Jbo.25.1.016002 |
0.515 |
|
2019 |
Torabzadeh M, Stockton P, Kennedy G, Saager R, Durkin AJ, Bartels R, Tromberg B. Hyperspectral imaging in the spatial frequency domain with a supercontinuum source. Journal of Biomedical Optics. 24: 1-9. PMID 31271005 DOI: 10.1117/1.Jbo.24.7.071614 |
0.759 |
|
2019 |
Saager RB, Rowland RA, Baldado ML, Kennedy GT, Bernal NP, Ponticorvo A, Christy RJ, Durkin AJ. Impact of hemoglobin breakdown products in the spectral analysis of burn wounds using spatial frequency domain spectroscopy. Journal of Biomedical Optics. 24: 1-4. PMID 30724041 DOI: 10.1117/1.Jbo.24.2.020501 |
0.781 |
|
2018 |
Horan ST, Gardner AR, Saager R, Durkin AJ, Venugopalan V. Recovery of layered tissue optical properties from spatial frequency-domain spectroscopy and a deterministic radiative transport solver. Journal of Biomedical Optics. 24: 1-11. PMID 30456934 DOI: 10.1117/1.Jbo.24.7.071607 |
0.655 |
|
2018 |
Saager RB, Baldado ML, Rowland RA, Kelly KM, Durkin AJ. Method using in vivo quantitative spectroscopy to guide design and optimization of low-cost, compact clinical imaging devices: emulation and evaluation of multispectral imaging systems. Journal of Biomedical Optics. 23: 1-12. PMID 29633609 DOI: 10.1117/1.Jbo.23.4.046002 |
0.683 |
|
2018 |
Ponticorvo A, Rowland R, Baldado M, Kennedy GT, Saager R, Burmeister DM, Christy RJ, Bernal N, Durkin AJ. 529 Evaluating Clinical Observation, Spatial Frequency Domain Imaging (SFDI) and Laser Speckle Imaging (LSI) for the Assessment of Burns Journal of Burn Care & Research. 39: S238-S239. DOI: 10.1093/Jbcr/Iry006.452 |
0.768 |
|
2017 |
Fredriksson I, Saager RB, Durkin AJ, Strömberg T. Evaluation of a pointwise microcirculation assessment method using liquid and multilayered tissue simulating phantoms. Journal of Biomedical Optics. 22: 1-9. PMID 29139245 DOI: 10.1117/1.Jbo.22.11.115004 |
0.646 |
|
2017 |
Saager RB, Dang AN, Huang SS, Kelly KM, Durkin AJ. Portable (handheld) clinical device for quantitative spectroscopy of skin, utilizing spatial frequency domain reflectance techniques. The Review of Scientific Instruments. 88: 094302. PMID 28964218 DOI: 10.1063/1.5001075 |
0.697 |
|
2017 |
Kennedy GT, Lentsch GR, Trieu B, Ponticorvo A, Saager RB, Durkin AJ. Solid tissue simulating phantoms having absorption at 970 nm for diffuse optics. Journal of Biomedical Optics. 22: 76013. PMID 28727869 DOI: 10.1117/1.Jbo.22.7.076013 |
0.796 |
|
2017 |
Ponticorvo A, Burmeister DM, Rowland R, Baldado M, Kennedy GT, Saager R, Bernal N, Choi B, Durkin AJ. Quantitative long-term measurements of burns in a rat model using Spatial Frequency Domain Imaging (SFDI) and Laser Speckle Imaging (LSI). Lasers in Surgery and Medicine. PMID 28220508 DOI: 10.1002/Lsm.22647 |
0.774 |
|
2017 |
Saager RB, Dang AN, Huang SS, Kelly KM, Durkin AJ. Handheld spatial frequency domain spectrographic imager for depth-sensitive, quantitative spectroscopy of skin tissue Proceedings of Spie. 10037: 1003703. DOI: 10.1117/12.2252518 |
0.7 |
|
2017 |
Kennedy GT, Lentsch GR, Trieu B, Ponticorvo A, Saager RB, Durkin AJ. Design and fabrication of solid phantoms for NIR water fraction studies Proceedings of Spie. 10056. DOI: 10.1117/12.2250672 |
0.791 |
|
2017 |
Fredriksson I, Saager RB, Durkin AJ, Strömberg T. Evaluation of a multi-layer diffuse reflectance spectroscopy system using optical phantoms Proceedings of Spie. 10056. DOI: 10.1117/12.2249562 |
0.655 |
|
2016 |
Burns JM, Saager R, Majaron B, Jia W, Anvari B. Optical properties of biomimetic probes engineered from erythrocytes. Nanotechnology. 28: 035101. PMID 27966473 DOI: 10.1088/1361-6528/28/3/035101 |
0.402 |
|
2016 |
Vasefi F, MacKinnon N, Saager R, Kelly KM, Maly T, Booth N, Durkin AJ, Farkas DL. Separating melanin from hemodynamics in nevi using multimode hyperspectral dermoscopy and spatial frequency domain spectroscopy. Journal of Biomedical Optics. 21: 114001. PMID 27830262 DOI: 10.1117/1.Jbo.21.11.114001 |
0.66 |
|
2016 |
Saager RB, Quach A, Rowland RA, Baldado ML, Durkin AJ. Low-cost tissue simulating phantoms with adjustable wavelength-dependent scattering properties in the visible and infrared ranges. Journal of Biomedical Optics. 21: 67001. PMID 27292135 DOI: 10.1117/1.Jbo.21.6.067001 |
0.64 |
|
2016 |
Saager RB, Sharif A, Kelly KM, Durkin AJ. In vivo isolation of the effects of melanin from underlying hemodynamics across skin types using spatial frequency domain spectroscopy. Journal of Biomedical Optics. 21: 57001. PMID 27143641 DOI: 10.1117/1.Jbo.21.5.057001 |
0.659 |
|
2016 |
Saager RB, Quach A, Kennedy GT, Tromberg BJ, Durkin AJ. From theory to practice: the broadening role of polydimethylsiloxane phantoms as an intermediary between model validation and instrument performance testing(Conference Presentation) Proceedings of Spie. 9700. DOI: 10.1117/12.2218388 |
0.717 |
|
2016 |
Vasefi F, MacKinnon N, Saager R, Kelly KM, Maly T, Chave R, Booth N, Durkin AJ, Farkas DL. Multimode optical dermoscopy (SkinSpect) analysis for skin with melanocytic nevus Proceedings of Spie. 9711: 971110. DOI: 10.1117/12.2214288 |
0.667 |
|
2016 |
Ponticorvo A, Rowland RA, Baldado ML, Kennedy GT, Saager RB, Choi B, Durkin AJ. Quantitative long term measurements of burns in a rat model using spatial frequency domain imaging and laser speckle imaging(Conference Presentation) Proceedings of Spie. 9711: 971102. DOI: 10.1117/12.2214080 |
0.768 |
|
2016 |
Saager RB, Quach A, Rowland RA, Baldado ML, Ponticorvo A, Durkin AJ. Low-cost tissue simulating phantoms with tunable, wavelength-dependent scattering properties(Conference Presentation) Proceedings of Spie. 9700: 970005. DOI: 10.1117/12.2212940 |
0.776 |
|
2015 |
Moy AJ, Capulong BV, Saager RB, Wiersma MP, Lo PC, Durkin AJ, Choi B. Optical properties of mouse brain tissue after optical clearing with FocusClear™. Journal of Biomedical Optics. 20: 95010. PMID 26388460 DOI: 10.1117/1.Jbo.20.9.095010 |
0.647 |
|
2015 |
Rohrbach DJ, Zeitouni NC, Muffoletto D, Saager R, Tromberg BJ, Sunar U. Characterization of nonmelanoma skin cancer for light therapy using spatial frequency domain imaging. Biomedical Optics Express. 6: 1761-6. PMID 26137378 DOI: 10.1364/Boe.6.001761 |
0.585 |
|
2015 |
Saager RB, Balu M, Crosignani V, Sharif A, Durkin AJ, Kelly KM, Tromberg BJ. In vivo measurements of cutaneous melanin across spatial scales: using multiphoton microscopy and spatial frequency domain spectroscopy. Journal of Biomedical Optics. 20: 066005. PMID 26065839 DOI: 10.1117/1.Jbo.20.6.066005 |
0.724 |
|
2015 |
Nicolau DV, Saager R, Durkin AJ, Chave R, Farkas DL. Quantifying the optical properties of turbid media using polarization sensitive hyperspectral imaging (SkinSpect): Two-layer optical phantom studies Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9328. DOI: 10.1117/12.2186031 |
0.659 |
|
2015 |
Saager RB, Balu M, Crosignani V, Sharif A, Durkin AJ, Kelly KM, Tromberg BJ. In vivo measurements of cutaneous melanin across spatial scales: Using multiphoton microscopy and spatial frequency domain spectroscopy Journal of Biomedical Optics. 20. DOI: 10.1117/1.JBO.20.6.066005 |
0.656 |
|
2014 |
Wilson RH, Nadeau KP, Jaworski FB, Rowland R, Nguyen JQ, Crouzet C, Saager RB, Choi B, Tromberg BJ, Durkin AJ. Quantitative short-wave infrared multispectral imaging of in vivo tissue optical properties. Journal of Biomedical Optics. 19: 086011. PMID 25120175 DOI: 10.1117/1.Jbo.19.8.086011 |
0.805 |
|
2014 |
Vasefi F, MacKinnon N, Saager RB, Durkin AJ, Chave R, Lindsley EH, Farkas DL. Polarization-sensitive hyperspectral imaging in vivo: a multimode dermoscope for skin analysis. Scientific Reports. 4: 4924. PMID 24815987 DOI: 10.1038/Srep04924 |
0.656 |
|
2014 |
Rohrbach DJ, Muffoletto D, Huihui J, Saager R, Keymel K, Paquette A, Morgan J, Zeitouni N, Sunar U. Preoperative mapping of nonmelanoma skin cancer using spatial frequency domain and ultrasound imaging. Academic Radiology. 21: 263-70. PMID 24439339 DOI: 10.1016/J.Acra.2013.11.013 |
0.382 |
|
2014 |
Sunar U, Rohrbach D, Muffoletto D, Saager RB, Mo W, Kowalczewski A, Morgan J, Paquette A, Tromberg BJ, Zeitouni N. Characterization of nonmelanoma skin cancer with multimodal imaging Ieee Transactions On Biomedical Engineering. DOI: 10.1364/Biomed.2014.Bs5A.5 |
0.369 |
|
2013 |
Saager RB, Cuccia DJ, Saggese S, Kelly KM, Durkin AJ. A Light Emitting Diode (LED) based spatial frequency domain imaging system for optimization of photodynamic therapy of nonmelanoma skin cancer: Quantitative reflectance imaging Lasers in Surgery and Medicine. 45: 207-215. PMID 23619900 DOI: 10.1002/Lsm.22139 |
0.638 |
|
2013 |
Saager RB, Hassan KM, Kondru C, Durkin AJ, Kelly KM. Quantitative near infrared spectroscopic analysis of Q-Switched Nd:YAG treatment of generalized argyria Lasers in Surgery and Medicine. 45: 15-21. PMID 23322674 DOI: 10.1002/Lsm.22084 |
0.559 |
|
2013 |
Vasefi F, Saager R, Durkin AJ, MacKinnon N, Gussakovsky E, Chave R, Farkas DL. Quantifying the optical properties and chromophore concentrations of turbid media using polarization sensitive hyperspectral imaging: Optical phantom studies Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8587. DOI: 10.1117/12.2005371 |
0.71 |
|
2012 |
Saager RB, Au K, Kelly KM, Durkin AJ. Development of spatial frequency domain instrument for the quantification of layer specific optical properties of pigmented lesions Biomedical Optics, Biomed 2012. BW4B.2. DOI: 10.1364/Biomed.2012.Bw4B.2 |
0.653 |
|
2011 |
Saager RB, Cuccia DJ, Saggese S, Kelly KM, Durkin AJ. Quantitative fluorescence imaging of protoporphyrin IX through determination of tissue optical properties in the spatial frequency domain Journal of Biomedical Optics. 16. PMID 22191930 DOI: 10.1117/1.3665440 |
0.696 |
|
2011 |
Nguyen JQ, Saager RB, Cuccia DJ, Kelly KM, Jakowatz J, Hsiang D, Durkin AJ. Effects of motion on optical properties in the spatial frequency domain Journal of Biomedical Optics. 16. PMID 22191926 DOI: 10.1117/1.3662454 |
0.656 |
|
2011 |
Saager RB, Truong A, Cuccia DJ, Durkin AJ. Method for depth-resolved quantitation of optical properties in layered media using spatially modulated quantitative spectroscopy. Journal of Biomedical Optics. 16: 077002. PMID 21806282 DOI: 10.1117/1.3597621 |
0.655 |
|
2011 |
Saager RB, Telleri NL, Berger AJ. Two-detector Corrected Near Infrared Spectroscopy (C-NIRS) detects hemodynamic activation responses more robustly than single-detector NIRS. Neuroimage. 55: 1679-85. PMID 21256223 DOI: 10.1016/J.Neuroimage.2011.01.043 |
0.581 |
|
2011 |
Yafi A, Vetter TS, Scholz T, Patel S, Saager RB, Cuccia DJ, Evans GR, Durkin AJ. Postoperative quantitative assessment of reconstructive tissue status in a cutaneous flap model using spatial frequency domain imaging. Plastic and Reconstructive Surgery. 127: 117-30. PMID 21200206 DOI: 10.1097/Prs.0B013E3181F959Cc |
0.753 |
|
2011 |
Nguyen JQ, Saager RB, Cuccia DJ, Kelly KM, Hsiang D, Durkin AJ. Motion correction in spatial frequency domain imaging; optical property determination in pigmented lesions Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7883. DOI: 10.1117/12.876720 |
0.629 |
|
2010 |
Saager RB, Cuccia DJ, Durkin AJ. Determination of optical properties of turbid media spanning visible and near-infrared regimes via spatially modulated quantitative spectroscopy. Journal of Biomedical Optics. 15: 017012. PMID 20210486 DOI: 10.1117/1.3299322 |
0.687 |
|
2010 |
Saager RB, Cuccia DJ, Saggese S, Kelly KM, Durkin AJ. A LED based spatial frequency domain imaging system for optimization of photodynamic therapy of basal cell carcinoma (BCC) Optics Infobase Conference Papers. DOI: 10.1364/Fio.2010.Ftus2 |
0.633 |
|
2010 |
Saager RB, Kondru C, Au K, Sry K, Ayers F, Durkin AJ. Multilayer silicone phantoms for the evaluation of quantitative optical techniques in skin imaging Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7567. DOI: 10.1117/12.842249 |
0.664 |
|
2008 |
Saager R, Berger A. Measurement of layer-like hemodynamic trends in scalp and cortex: implications for physiological baseline suppression in functional near-infrared spectroscopy. Journal of Biomedical Optics. 13: 034017. PMID 18601562 DOI: 10.1117/1.2940587 |
0.621 |
|
2006 |
Saager RB, Berger AJ. Application of a Dual-Detector scheme for biological noise removal in NIRS cerebral hemodynamics monitoring Frontiers in Optics. DOI: 10.1364/Fio.2006.Fwv4 |
0.591 |
|
2006 |
Berger AJ, Saager RB. Characterization of scalp—and brain-layer heterogeneity for near infrared spectroscopy Biomedical Optics. DOI: 10.1364/Bio.2006.Me36 |
0.589 |
|
2005 |
Saager RB, Berger AJ. Direct characterization and removal of interfering absorption trends in two-layer turbid media. Journal of the Optical Society of America. a, Optics, Image Science, and Vision. 22: 1874-82. PMID 16211814 DOI: 10.1364/Josaa.22.001874 |
0.641 |
|
2004 |
Saager RB, Berger AJ. Explicit removal of surface layer signals in NIRS cerebral hemodynamics monitoring Frontiers in Optics. DOI: 10.1364/Fio.2004.Ftug41 |
0.609 |
|
Show low-probability matches. |