☰

Dustin J. Tyler, Ph.D. - Publications

Affiliations: 
Biomedical Engineering Case Western Reserve University, Cleveland Heights, OH, United States 
Area:
Neural Engineering
Website:
http://bme.case.edu/FacultyStaff/PrimaryFaculty/Tyler/

91 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2023 Herring EZ, Graczyk EL, Memberg WD, Adams R, Fernandez Baca-Vaca G, Hutchison BC, Krall JT, Alexander BJ, Conlan EC, Alfaro KE, Bhat P, Ketting-Olivier AB, Haddix CA, Taylor DM, Tyler DJ, et al. Reconnecting the Hand and Arm to the Brain: Efficacy of Neural Interfaces for Sensorimotor Restoration After Tetraplegia. Neurosurgery. PMID 37982637 DOI: 10.1227/neu.0000000000002769  0.305
2023 Mesias LE, Gormez MA, Tyler DJ, Makowski NS, Graczyk EL, Fu MJ. Distally-referred surface electrical nerve stimulation (DR-SENS) for haptic feedback. Journal of Neural Engineering. PMID 37863034 DOI: 10.1088/1741-2552/ad0563  0.338
2022 Koppaka S, Hess-Dunning A, Tyler DJ. Biomechanical characterization of isolated epineurial and perineurial membranes of rabbit sciatic nerve. Journal of Biomechanics. 136: 111058. PMID 35349870 DOI: 10.1016/j.jbiomech.2022.111058  0.337
2021 Koppaka S, Hess-Dunning A, Tyler DJ. Directed stimulation with interfascicular interfaces for peripheral nerve stimulation. Journal of Neural Engineering. 18. PMID 34706351 DOI: 10.1088/1741-2552/ac33e8  0.406
2020 Freeberg MJ, Pinault GCJ, Tyler DJ, Triolo RJ, Ansari R. Chronic nerve health following implantation of femoral nerve cuff electrodes. Journal of Neuroengineering and Rehabilitation. 17: 95. PMID 32664972 DOI: 10.1186/S12984-020-00720-3  0.5
2020 Christie BP, Charkhkar H, Shell CE, Burant CJ, Tyler DJ, Triolo RJ. Ambulatory searching task reveals importance of somatosensation for lower-limb amputees. Scientific Reports. 10: 10216. PMID 32576891 DOI: 10.1038/S41598-020-67032-3  0.37
2020 Delianides C, Tyler D, Pinault G, Ansari R, Triolo R. Implanted High Density Cuff Electrodes Functionally Activate Human Tibial and Peroneal Motor Units Without Chronic Detriment to Peripheral Nerve Health. Neuromodulation : Journal of the International Neuromodulation Society. PMID 32189421 DOI: 10.1111/Ner.13110  0.508
2019 Dewald HA, Lukyanenko P, Lambrecht JM, Anderson JR, Tyler DJ, Kirsch RF, Williams MR. Stable, three degree-of-freedom myoelectric prosthetic control via chronic bipolar intramuscular electrodes: a case study. Journal of Neuroengineering and Rehabilitation. 16: 147. PMID 31752886 DOI: 10.1186/S12984-019-0607-8  0.367
2019 Freeberg MJ, Ansari R, Pinault GCJ, Lombardo LM, Miller ME, Tyler DJ, Triolo RJ. Intraoperative Responses May Predict Chronic Performance of Composite Flat Interface Nerve Electrodes on Human Femoral Nerves. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. PMID 31689196 DOI: 10.1109/Tnsre.2019.2951079  0.474
2019 Ereifej ES, Shell C, Schofield JS, Charkhkar H, Cuberovic I, Dorval AC, Graczyk EL, Kozai TDY, Otto KJ, Tyler DJ, Welle CG, Widge AS, Zariffa J, Moritz C, Bourbeau D, et al. Neural engineering: the process, applications, and its role in the future of medicine. Journal of Neural Engineering. PMID 31557730 DOI: 10.1088/1741-2552/Ab4869  0.703
2019 Gelenitis K, Sanner BM, J Triolo R, Tyler DJ. Selective Nerve Cuff Stimulation Strategies for Prolonging Muscle Output. Ieee Transactions On Bio-Medical Engineering. PMID 31449001 DOI: 10.1109/Tbme.2019.2937061  0.326
2019 Christie BP, Charkhkar H, Shell CE, Marasco PD, Tyler DJ, Triolo RJ. Visual inputs and postural manipulations affect the location of somatosensory percepts elicited by electrical stimulation. Scientific Reports. 9: 11699. PMID 31406122 DOI: 10.1038/S41598-019-47867-1  0.356
2019 Christie BP, Graczyk EL, Charkhkar H, Tyler DJ, Triolo RJ. Visuotactile synchrony of stimulation-induced sensation and natural somatosensation. Journal of Neural Engineering. PMID 30939464 DOI: 10.1088/1741-2552/Ab154C  0.46
2018 Schiefer MA, Graczyk EL, Sidik SM, Tan DW, Tyler DJ. Artificial tactile and proprioceptive feedback improves performance and confidence on object identification tasks. Plos One. 13: e0207659. PMID 30517154 DOI: 10.1371/Journal.Pone.0207659  0.686
2018 Hess-Dunning A, Tyler DJ. A Mechanically-Adaptive Polymer Nanocomposite-Based Intracortical Probe and Package for Chronic Neural Recording. Micromachines. 9. PMID 30413034 DOI: 10.3390/Mi9110583  0.38
2018 Graczyk EL, Resnik L, Schiefer MA, Schmitt MS, Tyler DJ. Home Use of a Neural-connected Sensory Prosthesis Provides the Functional and Psychosocial Experience of Having a Hand Again. Scientific Reports. 8: 9866. PMID 29959334 DOI: 10.1038/S41598-018-26952-X  0.727
2018 Charkhkar H, Shell C, Marasco P, Pinault G, Tyler DJ, Triolo RJ. High-density peripheral nerve cuffs restore natural sensation to individuals with lower-limb amputations. Journal of Neural Engineering. PMID 29855427 DOI: 10.1088/1741-2552/Aac964  0.518
2018 Graczyk EL, Delhaye B, Schiefer MA, Bensmaia SJ, Tyler DJ. Sensory adaptation to electrical stimulation of the somatosensory nerves. Journal of Neural Engineering. PMID 29551756 DOI: 10.1088/1741-2552/Aab790  0.756
2017 Brill NA, Naufel SN, Polasek KH, Ethier C, Cheesborough J, Agnew S, Miller LE, Tyler DJ. Evaluation of high-density, multi-contact nerve cuffs for activation of grasp muscles in monkeys. Journal of Neural Engineering. PMID 28825407 DOI: 10.1088/1741-2552/Aa8735  0.466
2017 Christie BP, Freeberg M, Memberg WD, Pinault GJC, Hoyen HA, Tyler DJ, Triolo RJ. "Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves". Journal of Neuroengineering and Rehabilitation. 14: 70. PMID 28693584 DOI: 10.1186/S12984-017-0285-3  0.501
2017 Freeberg M, Stone M, Triolo R, Tyler D. The design of and chronic tissue response to a composite nerve electrode with patterned stiffness. Journal of Neural Engineering. PMID 28287078 DOI: 10.1088/1741-2552/Aa6632  0.517
2016 Brill NA, Tyler DJ. Quantification of Human Upper Extremity Nerves and Fascicular Anatomy. Muscle & Nerve. PMID 28006854 DOI: 10.1002/Mus.25534  0.4
2016 Graczyk EL, Schiefer MA, Saal HP, Delhaye BP, Bensmaia SJ, Tyler DJ. The neural basis of perceived intensity in natural and artificial touch. Science Translational Medicine. 8: 362ra142. PMID 27797958 DOI: 10.1126/Scitranslmed.Aaf5187  0.756
2016 Dweiri YM, Stone MA, Tyler DJ, McCallum GA, Durand DM. Fabrication of High Contact-Density, Flat-Interface Nerve Electrodes for Recording and Stimulation Applications. Journal of Visualized Experiments : Jove. PMID 27768048 DOI: 10.3791/54388  0.633
2016 Tyler DJ. Restoring the human touch: Prosthetics imbued with haptics give their wearers fine motor control and a sense of connection Ieee Spectrum. 53: 28-33. DOI: 10.1109/Mspec.2016.7459116  0.412
2015 Schiefer M, Tan D, Sidek SM, Tyler DJ. Sensory feedback by peripheral nerve stimulation improves task performance in individuals with upper limb loss using a myoelectric prosthesis. Journal of Neural Engineering. 13: 016001. PMID 26643802 DOI: 10.1088/1741-2560/13/1/016001  0.702
2015 Nguyen JK, Jorfi M, Buchanan KL, Park DJ, Johan Foster E, Tyler DJ, Rowan SJ, Weder C, Capadona JR. Influence of resveratrol release on the tissue response to mechanically adaptive cortical implants. Acta Biomaterialia. PMID 26553391 DOI: 10.1016/J.Actbio.2015.11.001  0.784
2015 Tyler DJ. Neural interfaces for somatosensory feedback: bringing life to a prosthesis. Current Opinion in Neurology. 28: 574-81. PMID 26544029 DOI: 10.1097/Wco.0000000000000266  0.434
2015 Tan D, Tyler D, Sweet J, Miller J. Intensity Modulation: A Novel Approach to Percept Control in Spinal Cord Stimulation. Neuromodulation : Journal of the International Neuromodulation Society. PMID 26479774 DOI: 10.1111/Ner.12358  0.315
2015 Tan DW, Schiefer MA, Keith MW, Anderson JR, Tyler DJ. Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees. Journal of Neural Engineering. 12: 026002. PMID 25627310 DOI: 10.1088/1741-2560/12/2/026002  0.728
2015 Tyler DJ, Polasek KH, Schiefer MA. Peripheral Nerve Interfaces Nerves and Nerve Injuries. 2: 1033-1054. DOI: 10.1016/B978-0-12-802653-3.00112-3  0.715
2015 Schiefer MA, Tyler DJ. Computer Models of Peripheral Nerves Nerves and Nerve Injuries. 2: 1021-1032. DOI: 10.1016/B978-0-12-802653-3.00111-1  0.708
2014 Tan DW, Schiefer MA, Keith MW, Anderson JR, Tyler J, Tyler DJ. A neural interface provides long-term stable natural touch perception. Science Translational Medicine. 6: 257ra138. PMID 25298320 DOI: 10.1126/Scitranslmed.3008669  0.762
2014 Nguyen JK, Park DJ, Skousen JL, Hess-Dunning AE, Tyler DJ, Rowan SJ, Weder C, Capadona JR. Mechanically-compliant intracortical implants reduce the neuroinflammatory response. Journal of Neural Engineering. 11: 056014. PMID 25125443 DOI: 10.1088/1741-2560/11/5/056014  0.741
2014 Hadley AJ, Thompson P, Kolb I, Hahn EC, Tyler DJ. Targeted transtracheal stimulation for vocal fold closure. Dysphagia. 29: 346-54. PMID 24562508 DOI: 10.1007/S00455-014-9517-X  0.392
2014 Peterson EJ, Tyler DJ. Motor neuron activation in peripheral nerves using infrared neural stimulation. Journal of Neural Engineering. 11: 016001. PMID 24310923 DOI: 10.1088/1741-2560/11/1/016001  0.464
2014 Hahn EC, Hadley A, Tyler DJ, Maronian N. Clinical Feasibility Trial for Transtracheal Stimulation of Vocal Fold Closure in Sensate Human Subjects Otolaryngology–Head and Neck Surgery. 151: P187-P187. DOI: 10.1177/0194599814541629A155  0.398
2014 Hess-Dunning AE, Tyler DJ, Harris JP, Capadona JR, Weder C, Rowan SJ, Zorman CA. Microscale characterization of a mechanically adaptive polymer nanocomposite with cotton-derived cellulose nanocrystals for implantable BioMEMS Journal of Microelectromechanical Systems. 23: 774-784. DOI: 10.1109/Jmems.2014.2327035  0.749
2013 Harris JP, Tyler DJ. Biological, mechanical, and technological considerations affecting the longevity of intracortical electrode recordings. Critical Reviews in Biomedical Engineering. 41: 435-56. PMID 24940658 DOI: 10.1615/Critrevbiomedeng.2014010788  0.373
2013 Hess AE, Potter KA, Tyler DJ, Zorman CA, Capadona JR. Environmentally-controlled microtensile testing of mechanically-adaptive polymer nanocomposites for ex vivo characterization. Journal of Visualized Experiments : Jove. e50078. PMID 23995288 DOI: 10.3791/50078  0.748
2013 Schiefer MA, Freeberg M, Pinault GJ, Anderson J, Hoyen H, Tyler DJ, Triolo RJ. Selective activation of the human tibial and common peroneal nerves with a flat interface nerve electrode. Journal of Neural Engineering. 10: 056006. PMID 23918148 DOI: 10.1088/1741-2560/10/5/056006  0.752
2013 Hadley AJ, Kolb I, Tyler DJ. Laryngeal elevation by selective stimulation of the hypoglossal nerve. Journal of Neural Engineering. 10: 046013. PMID 23838089 DOI: 10.1088/1741-2560/10/4/046013  0.501
2013 Fisher LE, Tyler DJ, Triolo RJ. Optimization of selective stimulation parameters for multi-contact electrodes. Journal of Neuroengineering and Rehabilitation. 10: 25. PMID 23442372 DOI: 10.1186/1743-0003-10-25  0.499
2013 Tan D, Schiefer M, Keith MW, Anderson R, Tyler DJ. Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in a human amputee International Ieee/Embs Conference On Neural Engineering, Ner. 859-862. DOI: 10.1109/NER.2013.6696070  0.708
2012 Duke AR, Peterson E, Mackanos MA, Atkinson J, Tyler D, Jansen ED. Hybrid electro-optical stimulation of the rat sciatic nerve induces force generation in the plantarflexor muscles. Journal of Neural Engineering. 9: 066006. PMID 23186608 DOI: 10.1088/1741-2560/9/6/066006  0.405
2012 Broniatowski M, Grundfest-Broniatowski S, Hahn EC, Hadley AJ, Tyler DJ, Tucker HM. Selective intraoperative stimulation of the human larynx. The Laryngoscope. 122: 2015-22. PMID 22886746 DOI: 10.1002/Lary.23464  0.397
2012 Schiefer MA, Tyler DJ, Triolo RJ. Probabilistic modeling of selective stimulation of the human sciatic nerve with a flat interface nerve electrode. Journal of Computational Neuroscience. 33: 179-90. PMID 22222951 DOI: 10.1007/S10827-011-0381-5  0.768
2012 Capadona JR, Tyler DJ, Zorman CA, Rowan SJ, Weder C. Mechanically adaptive nanocomposites for neural interfacing Mrs Bulletin. 37: 581-589. DOI: 10.1557/Mrs.2012.97  0.773
2011 Schiefer MA, Tyler DJ, Triolo RJ. Probabilistic modeling of selective stimulation of the human sciatic nerve with a flat Interface Nerve Electrode. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2011: 4068-71. PMID 22255234 DOI: 10.1109/IEMBS.2011.6091011  0.753
2011 Fisher LE, Anderson JS, Tyler DJ, Triolo RJ. Optimization of stimulus parameters for selective peripheral nerve stimulation with multi-contact electrodes. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2011: 3039-42. PMID 22254980 DOI: 10.1109/IEMBS.2011.6090831  0.384
2011 Harris JP, Capadona JR, Miller RH, Healy BC, Shanmuganathan K, Rowan SJ, Weder C, Tyler DJ. Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies. Journal of Neural Engineering. 8: 066011. PMID 22049097 DOI: 10.1088/1741-2560/8/6/066011  0.755
2011 Peterson EJ, Izad O, Tyler DJ. Predicting myelinated axon activation using spatial characteristics of the extracellular field. Journal of Neural Engineering. 8: 046030. PMID 21750371 DOI: 10.1088/1741-2560/8/4/046030  0.302
2011 Harris JP, Hess AE, Rowan SJ, Weder C, Zorman CA, Tyler DJ, Capadona JR. In vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes. Journal of Neural Engineering. 8: 046010. PMID 21654037 DOI: 10.1088/1741-2560/8/4/046010  0.75
2011 Ackermann DM, Ethier C, Foldes EL, Oby ER, Tyler D, Bauman M, Bhadra N, Miller L, Kilgore KL. Electrical conduction block in large nerves: high-frequency current delivery in the nonhuman primate. Muscle & Nerve. 43: 897-9. PMID 21607972 DOI: 10.1002/Mus.22037  0.423
2011 Hess AE, Shanmuganathan K, Capadona JR, Hsu L, Rowan S, Weder C, Tyler DJ, Zorman CA. Mechanical behavior of microstructures from a chemo-responsive polymer nanocomposite based on cotton cellulose nanofibers Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 453-456. DOI: 10.1109/MEMSYS.2011.5734459  0.709
2011 Hess AE, Capadona JR, Shanmuganathan K, Hsu L, Rowan SJ, Weder C, Tyler DJ, Zorman CA. Development of a stimuli-responsive polymer nanocomposite toward biologically optimized, MEMS-based neural probes Journal of Micromechanics and Microengineering. 21. DOI: 10.1088/0960-1317/21/5/054009  0.751
2010 Broniatowski M, Moore NZ, Grundfest-Broniatowski S, Tucker HM, Lancaster E, Krival K, Hadley AJ, Tyler DJ. Paced glottic closure for controlling aspiration pneumonia in patients with neurologic deficits of various causes. The Annals of Otology, Rhinology, and Laryngology. 119: 141-9. PMID 20392026 DOI: 10.1177/000348941011900301  0.322
2010 Schiefer MA, Polasek KH, Triolo RJ, Pinault GC, Tyler DJ. Selective stimulation of the human femoral nerve with a flat interface nerve electrode. Journal of Neural Engineering. 7: 26006. PMID 20208125 DOI: 10.1088/1741-2560/7/2/026006  0.759
2010 Broniatowski M, Grundfest-Broniatowski S, Hadley AJ, Shah NS, Barbu AM, Phillipbar SA, Strohl KP, Tucker HM, Tyler DJ. Improvement of respiratory compromise through abductor reinnervation and pacing in a patient with bilateral vocal fold impairment. The Laryngoscope. 120: 76-83. PMID 19877193 DOI: 10.1002/Lary.20698  0.387
2009 Schiefer MA, Polasek KH, Triolo RJ, Pinault GC, Tyler DJ. Intraoperative demonstration of selective stimulation of the common human femoral nerve with a FINE. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2009: 610-3. PMID 19963718 DOI: 10.1109/IEMBS.2009.5332757  0.73
2009 Brill N, Polasek K, Oby E, Ethier C, Miller L, Tyler D. Nerve cuff stimulation and the effect of fascicular organization for hand grasp in nonhuman primates Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Conference. 1557-1560. PMID 19963509 DOI: 10.1109/IEMBS.2009.5332395  0.394
2009 Polasek KH, Schiefer MA, Pinault GC, Triolo RJ, Tyler DJ. Intraoperative evaluation of the spiral nerve cuff electrode on the femoral nerve trunk. Journal of Neural Engineering. 6: 066005. PMID 19901448 DOI: 10.1088/1741-2560/6/6/066005  0.756
2009 Polasek KH, Hoyen HA, Keith MW, Kirsch RF, Tyler DJ. Stimulation stability and selectivity of chronically implanted multicontact nerve cuff electrodes in the human upper extremity. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 17: 428-37. PMID 19775987 DOI: 10.1109/Tnsre.2009.2032603  0.509
2009 Fisher LE, Tyler DJ, Anderson JS, Triolo RJ. Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve. Journal of Neural Engineering. 6: 046010. PMID 19602729 DOI: 10.1088/1741-2560/6/4/046010  0.525
2009 Hess A, Dunning J, Harris J, Capadona JR, Shanmuganathan K, Rowan SJ, Weder C, Tyler DJ, Zorman CA. A bio-inspired, chemo-responsive polymer nanocomposite for mechanically dynamic microsystems Transducers 2009 - 15th International Conference On Solid-State Sensors, Actuators and Microsystems. 224-227. DOI: 10.1109/SENSOR.2009.5285522  0.712
2009 Tyler DJ, Polasek KH. Electrodes for the Neural Interface Neuromodulation. 1: 181-213. DOI: 10.1016/B978-0-12-374248-3.00018-5  0.452
2008 Grinberg Y, Schiefer MA, Tyler DJ, Gustafson KJ. Fascicular perineurium thickness, size, and position affect model predictions of neural excitation. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 16: 572-81. PMID 19144589 DOI: 10.1109/Tnsre.2008.2010348  0.757
2008 Fisher LE, Miller ME, Bailey SN, Davis JA, Anderson JS, Rhode L, Tyler DJ, Triolo RJ. Standing after spinal cord injury with four-contact nerve-cuff electrodes for quadriceps stimulation. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 16: 473-8. PMID 18990650 DOI: 10.1109/Tnsre.2008.2003390  0.451
2008 Broniatowski M, Grundfest-Broniatowski S, Zobenica NS, Tyler DJ. Artificial manipulation of voice in the human by an implanted stimulator. The Laryngoscope. 118: 1889-93. PMID 18758384 DOI: 10.1097/Mlg.0B013E31817E7452  0.405
2008 Schiefer MA, Triolo RJ, Tyler DJ. A model of selective activation of the femoral nerve with a flat interface nerve electrode for a lower extremity neuroprosthesis. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 16: 195-204. PMID 18403289 DOI: 10.1109/Tnsre.2008.918425  0.762
2008 Capadona JR, Shanmuganathan K, Tyler DJ, Rowan SJ, Weder C. Stimuli-responsive polymer nanocomposites inspired by the sea cucumber dermis. Science (New York, N.Y.). 319: 1370-4. PMID 18323449 DOI: 10.1126/Science.1153307  0.727
2008 Shanmuganathan K, Capadona JR, Tyler DJ, Rowan SJ, Weder C. Stimuli-responsive mechanically dynamic polymer nanocomposites American Chemical Society, Polymer Preprints, Division of Polymer Chemistry. 49: 1073.  0.712
2007 Capadona JR, Van Den Berg O, Capadona LA, Schroeter M, Rowan SJ, Tyler DJ, Weder C. A versatile approach for the processing of polymer nanocomposites with self-assembled nanofibre templates. Nature Nanotechnology. 2: 765-9. PMID 18654428 DOI: 10.1038/Nnano.2007.379  0.726
2007 Polasek KH, Hoyen HA, Keith MW, Tyler DJ. Human nerve stimulation thresholds and selectivity using a multi-contact nerve cuff electrode. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 15: 76-82. PMID 17436879 DOI: 10.1109/Tnsre.2007.891383  0.459
2007 Broniatowski M, Grundfest-Broniatowski S, Tucker HM, Tyler DJ. Artificial voice modulation in dogs by recurrent laryngeal nerve stimulation: electrophysiological confirmation of anatomic data. The Annals of Otology, Rhinology, and Laryngology. 116: 145-55. PMID 17388239 DOI: 10.1177/000348940711600211  0.461
2007 Polasek KH, Schiefer MA, Pinault GC, Triolo RJ, Tyler DJ. Intraoperative evaluation of the spiral nerve cuff electrode for a standing neuroprosthesis Proceedings of the 3rd International Ieee Embs Conference On Neural Engineering. 89-92. DOI: 10.1109/CNE.2007.369619  0.731
2007 Schiefer MA, Polasek KH, Pinault GC, Triolo RJ, Tyler DJ. Intraoperative evaluation of the first flat interface nerve electrode for a standing neuroprosthesis: A case report Proceedings of the 3rd International Ieee Embs Conference On Neural Engineering. 13-16. DOI: 10.1109/CNE.2007.369599  0.72
2006 Fisher LE, Miller ME, Nogan SJ, Davis JA, Anderson JS, Murray LM, Tyler DJ, Triolo RJ. Preliminary evaluation of a neural prosthesis for standing after spinal cord injury with four contact nerve-cuff electrodes for quadriceps stimulation. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 3592-5. PMID 17947042 DOI: 10.1109/IEMBS.2006.260833  0.333
2006 Polasek KH, Hoyen HA, Keith MW, Kirsch RF, Tyler DJ. Spiral nerve cuff electrodes for an upper extremity neuroprosthesis. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 3584-7. PMID 17947040 DOI: 10.1109/IEMBS.2006.259625  0.338
2006 Schiefer MA, Triolo RJ, Tyler DJ. Models of selective stimulation with a flat interface nerve electrode for standing neuroprosthetic systems. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 4639-42. PMID 17946642 DOI: 10.1109/IEMBS.2006.260049  0.738
2005 Schiefer MA, Triolo RJ, Durand DM, Tyler DJ. Modeling selective stimulation with a flat interface nerve electrode for standing neuroprosthetic systems 2nd International Ieee Embs Conference On Neural Engineering. 2005: 356-359. DOI: 10.1109/CNE.2005.1419631  0.739
2004 Polasek KH, Hoyen HA, Kirsch RF, Tyler DJ. Intraoperative testing of selectivity of spiral nerve cuff electrodes. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 6: 4137-40. PMID 17271212 DOI: 10.1109/IEMBS.2004.1404154  0.393
2003 Tyler DJ, Durand DM. Chronic response of the rat sciatic nerve to the flat interface nerve electrode. Annals of Biomedical Engineering. 31: 633-42. PMID 12797612 DOI: 10.1114/1.1569263  0.625
2002 Tyler DJ, Durand DM. Functionally selective peripheral nerve stimulation with a flat interface nerve electrode. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 10: 294-303. PMID 12611367 DOI: 10.1109/Tnsre.2002.806840  0.649
2001 Broniatowski M, Grundfest-Broniatowski S, Tyler DJ, Scolieri P, Abbass F, Tucker HM, Brodsky S. Dynamic laryngotracheal closure for aspiration: a preliminary report. The Laryngoscope. 111: 2032-40. PMID 11801992 DOI: 10.1097/00005537-200111000-00031  0.428
1999 Qi H, Tyler DJ, Durand DM. Neurofuzzy adaptive controlling of selective stimulation for FES: a case study. Ieee Transactions On Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 7: 183-92. PMID 10391589 DOI: 10.1109/86.769409  0.483
1997 Tyler DJ, Durand DM. A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves. Ieee Transactions On Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 5: 51-61. PMID 9086385 DOI: 10.1109/86.559349  0.608
1997 Tyler DJ, Durand DM. Alteration of neural geometry for selective nerve stimulation Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 5: 2002-2003.  0.566
1996 Tyler DJ, Durand DM. Selective stimulation with a chronic slowly penetrating interfascicular nerve electrode Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 351-352.  0.583
1994 Tyler DJ, Durand DM. Method of quantifying electrode performance based on non-invasive three dimensional isometric torque data Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 16: 357-358.  0.439
1993 Tyler DJ, Durand D. Design and acute test of a radially penetrating interfascicular nerve electrode Proceedings of the Annual Conference On Engineering in Medicine and Biology. 15: 1247-1248.  0.539
Show low-probability matches.