Year |
Citation |
Score |
2023 |
Zarei M, Abadi E, Segars WP, Samei E. Coronary stenosis quantification in cardiac computed tomography angiography: multi-factorial optimization of image quality and radiation dose. Journal of Medical Imaging (Bellingham, Wash.). 10: 063502. PMID 38156332 DOI: 10.1117/1.JMI.10.6.063502 |
0.307 |
|
2023 |
Schwartz FR, Ria F, McCabe C, Zarei M, Rajagopal J, Molvin L, Marin D, O'Sullivan-Murphy B, Kalisz KR, Tailor TD, Washington L, Henry T, Samei E. Image quality of photon counting and energy integrating chest CT - Prospective head-to-head comparison on same patients. European Journal of Radiology. 166: 111014. PMID 37542816 DOI: 10.1016/j.ejrad.2023.111014 |
0.3 |
|
2023 |
Bhattarai M, Bache S, Abadi E, Samei E. A systematic task-based image quality assessment of photon-counting and energy integrating CT as a function of reconstruction kernel and phantom size. Medical Physics. PMID 37469179 DOI: 10.1002/mp.16619 |
0.3 |
|
2023 |
Vrbaski S, Bache S, Rajagopal J, Samei E. Quantitative performance of photon-counting CT at low dose: Virtual monochromatic imaging and iodine quantification. Medical Physics. PMID 37415402 DOI: 10.1002/mp.16583 |
0.361 |
|
2023 |
Bache ST, Samei E. A methodology for incorporating a photon-counting CT system into routine clinical use. Journal of Applied Clinical Medical Physics. 24: e14069. PMID 37389963 DOI: 10.1002/acm2.14069 |
0.349 |
|
2023 |
Rajagopal JR, Schwartz FR, Solomon JB, Enterline DS, Samei E. High Spatial-Resolution Skull Base Imaging With Photon-Counting Computed Tomography and Energy-Integrating Computed Tomography: A Comparative Phantom Study. Journal of Computer Assisted Tomography. PMID 37380149 DOI: 10.1097/RCT.0000000000001464 |
0.383 |
|
2023 |
Zarei M, Sotoudeh-Paima S, McCabe C, Abadi E, Samei E. Harmonizing CT Images via Physics-based Deep Neural Networks. Proceedings of Spie--the International Society For Optical Engineering. 12463. PMID 37131954 DOI: 10.1117/12.2654215 |
0.353 |
|
2023 |
Ho FC, Sotoudeh-Paima S, Segars WP, Samei E, Abadi E. Development and Application of a Virtual Imaging Trial framework for Airway Quantifications via CT. Proceedings of Spie--the International Society For Optical Engineering. 12463. PMID 37125262 DOI: 10.1117/12.2654263 |
0.382 |
|
2023 |
Alsaihati N, Ria F, Solomon J, Ding A, Frush D, Samei E. Making CT Dose Monitoring Meaningful: Augmenting Dose with Imaging Quality. Tomography (Ann Arbor, Mich.). 9: 798-809. PMID 37104136 DOI: 10.3390/tomography9020065 |
0.33 |
|
2023 |
Schwartz FR, Samei E, Marin D. Exploiting the Potential of Photon-Counting CT in Abdominal Imaging. Investigative Radiology. PMID 36728045 DOI: 10.1097/RLI.0000000000000949 |
0.318 |
|
2023 |
Sauer TJ, Bejan A, Segars P, Samei E. Development and CT image-domain validation of a computational lung lesion model for use in virtual imaging trials. Medical Physics. PMID 36637206 DOI: 10.1002/mp.16222 |
0.301 |
|
2022 |
Abadi E, Jadick G, Lynch DA, Segars WP, Samei E. Emphysema quantifications with CT: Assessing the effects of acquisition protocols and imaging parameters using virtual imaging trials. Chest. PMID 36462532 DOI: 10.1016/j.chest.2022.11.033 |
0.31 |
|
2022 |
Schwartz FR, Vinson EN, Spritzer CE, Colglazier R, Samei E, French RJ, Said N, Waldman L, McCrum E. Prospective Multireader Evaluation of Photon-counting CT for Multiple Myeloma Screening. Radiology. Imaging Cancer. 4: e220073. PMID 36399038 DOI: 10.1148/rycan.220073 |
0.359 |
|
2022 |
Ahmad M, Liu X, Morani AC, Ganeshan D, Anderson MR, Samei E, Jensen CT. Oncology-specific radiation dose and image noise reference levels in adult abdominal-pelvic CT. Clinical Imaging. 93: 52-59. PMID 36375364 DOI: 10.1016/j.clinimag.2022.10.016 |
0.323 |
|
2022 |
Shankar SS, Felice N, Hoffman EA, Atha J, Sieren JC, Samei E, Abadi E. Task-based validation and application of a scanner-specific CT simulator using an anthropomorphic phantom. Medical Physics. PMID 36097259 DOI: 10.1002/mp.15967 |
0.358 |
|
2022 |
Lorenzana DJ, Solomon J, French RJ, McCrum E, Jonkergouw F, Anakwenze OA, Lassiter T, Samei E, Klifto CS. Comparison of Simulated Low-Dose and Conventional-Dose CT for Preoperative Planning in Shoulder Arthroplasty. The Journal of Bone and Joint Surgery. American Volume. 104: 1004-1014. PMID 35648067 DOI: 10.2106/JBJS.20.01916 |
0.312 |
|
2022 |
Abadi E, McCabe C, Harrawood B, Sotoudeh-Paima S, Segars WP, Samei E. Development and Clinical Applications of a Virtual Imaging Framework for Optimizing Photon-counting CT. Proceedings of Spie--the International Society For Optical Engineering. 12031. PMID 35611365 DOI: 10.1117/12.2612079 |
0.398 |
|
2022 |
Sotoudeh-Paima S, Segars WP, Samei E, Abadi E. Photon-counting CT versus conventional CT for COPD quantifications: intra-scanner optimization and inter-scanner assessments using virtual imaging trials. Proceedings of Spie--the International Society For Optical Engineering. 12031. PMID 35574205 DOI: 10.1117/12.2613003 |
0.355 |
|
2022 |
Zarei M, Sotoudeh-Paima S, Abadi E, Samei E. A truth-based primal-dual learning approach to reconstruct CT images utilizing the virtual imaging trial platform. Proceedings of Spie--the International Society For Optical Engineering. 12031. PMID 35574204 DOI: 10.1117/12.2613168 |
0.359 |
|
2022 |
Shankar SS, Hoffman EA, Atha J, Sieren JC, Samei E, Abadi E. Inter- and intra-scan variability for lung imaging quantifications via CT. Proceedings of Spie--the International Society For Optical Engineering. 12031. PMID 35547179 DOI: 10.1117/12.2613191 |
0.336 |
|
2022 |
Shankar SS, Jadick GL, Hoffman EA, Atha J, Sieren JC, Samei E, Abadi E. Scanner-specific validation of a CT simulator using a COPD-emulated anthropomorphic phantom. Proceedings of Spie--the International Society For Optical Engineering. 12031. PMID 35547178 DOI: 10.1117/12.2613212 |
0.361 |
|
2022 |
Sauer TJ, Abadi E, Segars P, Samei E. Anatomically- and physiologically-informed computational model of hepatic contrast perfusion for virtual imaging trials. Medical Physics. PMID 35195901 DOI: 10.1002/mp.15562 |
0.309 |
|
2022 |
Jensen CT, Gupta S, Saleh MM, Liu X, Wong VK, Salem U, Qiao W, Samei E, Wagner-Bartak NA. Reduced-Dose Deep Learning Reconstruction for Abdominal CT of Liver Metastases. Radiology. 211838. PMID 35014900 DOI: 10.1148/radiol.211838 |
0.309 |
|
2021 |
Smith TB, Abadi E, Solomon J, Samei E. Development, validation, and relevance of in vivo low-contrast task transfer function to estimate detectability in clinical CT images. Medical Physics. 48: 7698-7711. PMID 34713908 DOI: 10.1002/mp.15309 |
0.304 |
|
2021 |
Jadick GL, Abadi E, Harrawood BP, Sharma S, Segars PW, Samei E. A scanner-specific framework for simulating CT images with tube current modulation. Physics in Medicine and Biology. PMID 34464942 DOI: 10.1088/1361-6560/ac2269 |
0.368 |
|
2021 |
Rajagopal JR, Sahbaee P, Farhadi F, Solomon JB, Ramirez-Giraldo JC, Pritchard WF, Wood BJ, Jones EC, Samei E. A Clinically Driven Task-Based Comparison of Photon Counting and Conventional Energy Integrating CT for Soft Tissue, Vascular, and High-Resolution Tasks. Ieee Transactions On Radiation and Plasma Medical Sciences. 5: 588-595. PMID 34250326 DOI: 10.1109/trpms.2020.3019954 |
0.305 |
|
2021 |
Smith TB, Zhang S, Erkanli A, Frush D, Samei E. Variability in image quality and radiation dose within and across 97 medical facilities. Journal of Medical Imaging (Bellingham, Wash.). 8: 052105. PMID 33977114 DOI: 10.1117/1.JMI.8.5.052105 |
0.36 |
|
2021 |
Sharma S, Abadi E, Kapadia AJ, Segars PW, Samei E. A GPU-accelerated framework for rapid estimation of scanner-specific scatter in CT for virtual imaging trials. Physics in Medicine and Biology. PMID 33652421 DOI: 10.1088/1361-6560/abeb32 |
0.306 |
|
2021 |
Fu W, Sharma S, Abadi E, Iliopoulos AS, Wang Q, Sun X, Lo JY, Segars WP, Samei E. Phantom: A framework for automated creation of individualized computational phantoms and its application to CT organ dosimetry. Ieee Journal of Biomedical and Health Informatics. PMID 33651703 DOI: 10.1109/JBHI.2021.3063080 |
0.335 |
|
2021 |
Samei E, Richards T, Segars WP, Daubert MA, Ivanov A, Rubin GD, Douglas PS, Hoffmann U. Task-dependent estimability index to assess the quality of cardiac computed tomography angiography for quantifying coronary stenosis. Journal of Medical Imaging (Bellingham, Wash.). 8: 013501. PMID 33447644 DOI: 10.1117/1.JMI.8.1.013501 |
0.331 |
|
2021 |
Smith TB, Heil J, Frush DP, Samei E. Clinical concordance with Image Gently guidelines for pediatric computed tomography: a study across 663,417 CT scans at 53 clinical facilities. Pediatric Radiology. PMID 33404787 DOI: 10.1007/s00247-020-04909-5 |
0.353 |
|
2020 |
Rajagopal JR, Farhadi F, Solomon J, Sahbaee P, Saboury B, Pritchard WF, Jones EC, Samei E. Comparison of Low Dose Performance of Photon-Counting and Energy Integrating CT. Academic Radiology. PMID 32855051 DOI: 10.1016/J.Acra.2020.07.033 |
0.427 |
|
2020 |
Hoye J, Solomon JB, Sauer TJ, Samei E. Quantification of Minimum Detectable Difference in Radiomics Features Across Lesions and CT Imaging Conditions. Academic Radiology. PMID 32828664 DOI: 10.1016/J.Acra.2020.07.029 |
0.417 |
|
2020 |
Abadi E, Paul Segars W, Chalian H, Samei E. Virtual Imaging Trials for Coronavirus Disease (COVID-19). Ajr. American Journal of Roentgenology. 1-7. PMID 32822224 DOI: 10.2214/Ajr.20.23429 |
0.469 |
|
2020 |
Samei E, Ria F, Tian X, Segars PW. A database of 40 patient-based computational models for benchmarking organ dose estimates in CT. Medical Physics. PMID 32628272 DOI: 10.1002/Mp.14373 |
0.383 |
|
2020 |
Ding Y, Marin D, Vernuccio F, Gonzalez F, Williamson HV, Becker HC, Patel BN, Solomon J, Ramirez-Giraldo JC, Samei E, Nelson RC, Meyer M. Variability of quantitative measurements of metastatic liver lesions: a multi-radiation-dose-level and multi-reader comparison. Abdominal Radiology (New York). PMID 32524151 DOI: 10.1007/S00261-020-02601-8 |
0.315 |
|
2020 |
Abadi E, Segars WP, Harrawood B, Sharma S, Kapadia A, Samei E. Virtual clinical trial for quantifying the effects of beam collimation and pitch on image quality in computed tomography. Journal of Medical Imaging (Bellingham, Wash.). 7: 042806. PMID 32509918 DOI: 10.1117/1.Jmi.7.4.042806 |
0.429 |
|
2020 |
Solomon J, Lyu P, Marin D, Samei E. Noise and spatial resolution properties of a commercially available deep-learning based CT reconstruction algorithm. Medical Physics. PMID 32506661 DOI: 10.1002/Mp.14319 |
0.329 |
|
2020 |
Abadi E, Segars WP, Tsui BMW, Kinahan PE, Bottenus N, Frangi AF, Maidment A, Lo J, Samei E. Virtual clinical trials in medical imaging: a review. Journal of Medical Imaging (Bellingham, Wash.). 7: 042805. PMID 32313817 DOI: 10.1117/1.Jmi.7.4.042805 |
0.405 |
|
2020 |
Nelson JS, Samei E. Automated quality control in nuclear medicine using the structured noise index. Journal of Applied Clinical Medical Physics. PMID 32277546 DOI: 10.1002/Acm2.12850 |
0.341 |
|
2020 |
Lacy T, Ding A, Minkemeyer V, Frush D, Samei E. Patient-based Performance Assessment for Pediatric Abdominal CT: An Automated Monitoring System Based on Lesion Detectability and Radiation Dose. Academic Radiology. PMID 32063494 DOI: 10.1016/J.Acra.2020.01.018 |
0.431 |
|
2020 |
Ria F, Solomon JB, Wilson JM, Samei E. Technical Note: Validation of TG 233 phantom methodology to characterize noise and dose in patient CT data. Medical Physics. PMID 32040862 DOI: 10.1002/Mp.14089 |
0.49 |
|
2019 |
Abadi E, Harrawood B, Rajagopal JR, Sharma S, Kapadia A, Segars WP, Stierstorfer K, Sedlmair M, Jones E, Samei E. Development of a scanner-specific simulation framework for photon-counting computed tomography. Biomedical Physics & Engineering Express. 5. PMID 33304618 DOI: 10.1088/2057-1976/Ab37E9 |
0.477 |
|
2019 |
Meyer M, Ronald J, Vernuccio F, Nelson RC, Ramirez-Giraldo JC, Solomon J, Patel BN, Samei E, Marin D. Reproducibility of CT Radiomic Features within the Same Patient: Influence of Radiation Dose and CT Reconstruction Settings. Radiology. 190928. PMID 31573400 DOI: 10.1148/Radiol.2019190928 |
0.379 |
|
2019 |
Sharma S, Kapadia AJ, Fu W, Abadi E, Segars PW, Samei E. A real-time Monte Carlo tool for individualized dose estimations in clinical CT. Physics in Medicine and Biology. PMID 31539892 DOI: 10.1088/1361-6560/Ab467F |
0.387 |
|
2019 |
Samei E, Grist TM. Why physics in medicine? Physica Medica : Pm : An International Journal Devoted to the Applications of Physics to Medicine and Biology : Official Journal of the Italian Association of Biomedical Physics (Aifb). 64: 319-322. PMID 31515032 DOI: 10.1016/J.Ejmp.2019.04.027 |
0.345 |
|
2019 |
Cheng Y, Abadi E, Brunton Smith T, Ria F, Meyer M, Marin D, Samei E. Validation of Algorithmic CT Image Quality Metrics with Preferences of Radiologists. Medical Physics. PMID 31465538 DOI: 10.1002/Mp.13795 |
0.425 |
|
2019 |
Cheng Y, Smith TB, Jensen CT, Liu X, Samei E. Correlation of Algorithmic and Visual Assessment of Lesion Detection in Clinical Images. Academic Radiology. PMID 31447259 DOI: 10.1016/J.Acra.2019.07.015 |
0.467 |
|
2019 |
Hoye J, Sharma S, Zhang Y, Fu W, Ria F, Kapadia A, Segars WP, Wilson J, Samei E. Organ Doses from CT Localizer Radiographs: Development, Validation, and Application of a Monte Carlo Estimation Technique. Medical Physics. PMID 31442324 DOI: 10.1002/Mp.13781 |
0.367 |
|
2019 |
Samei E, Bakalyar D, Boedeker KL, Brady S, Fan J, Leng S, Myers KJ, Popescu LM, Ramirez Giraldo JC, Ranallo F, Solomon J, Vaishnav J, Wang J. Performance Evaluation of Computed Tomography Systems: Summary of AAPM Task Group 233. Medical Physics. PMID 31408540 DOI: 10.1002/Mp.13763 |
0.403 |
|
2019 |
Robins M, Solomon J, Hoye J, Abadi E, Marin D, Samei E. Systematic analysis of bias and variability of texture measurements in computed tomography. Journal of Medical Imaging (Bellingham, Wash.). 6: 033503. PMID 31338387 DOI: 10.1117/1.Jmi.6.3.033503 |
0.462 |
|
2019 |
Samei E, Hoye J, Zheng Y, Solomon JB, Marin D. Design and fabrication of heterogeneous lung nodule phantoms for assessing the accuracy and variability of measured texture radiomics features in CT. Journal of Medical Imaging (Bellingham, Wash.). 6: 021606. PMID 31263737 DOI: 10.1117/1.Jmi.6.2.021606 |
0.445 |
|
2019 |
Ria F, Davis JT, Solomon JB, Wilson JM, Smith TB, Frush DP, Samei E. Expanding the Concept of Diagnostic Reference Levels to Noise and Dose Reference Levels in CT. Ajr. American Journal of Roentgenology. 1-6. PMID 31180737 DOI: 10.2214/Ajr.18.21030 |
0.453 |
|
2019 |
Jordan DW, Gingold EL, Samei E. Automation, regulation, and collaboration: Threats and opportunities for clinical medical physics careers in diagnostic imaging and nuclear medicine. Journal of Applied Clinical Medical Physics. PMID 31081249 DOI: 10.1002/Acm2.12604 |
0.333 |
|
2019 |
Hoye J, Solomon J, Sauer TJ, Robins M, Samei E. Systematic analysis of bias and variability of morphologic features for lung lesions in computed tomography. Journal of Medical Imaging (Bellingham, Wash.). 6: 013504. PMID 30944842 DOI: 10.1117/1.Jmi.6.1.013504 |
0.422 |
|
2019 |
Rossman AH, Catenacci M, Zhao C, Sikaria D, Knudsen JE, Dawes D, Gehm ME, Samei E, Wiley BJ, Lo JY. Three-dimensionally-printed anthropomorphic physical phantom for mammography and digital breast tomosynthesis with custom materials, lesions, and uniform quality control region. Journal of Medical Imaging (Bellingham, Wash.). 6: 021604. PMID 30915385 DOI: 10.1117/1.Jmi.6.2.021604 |
0.352 |
|
2019 |
Meyer M, Nelson RC, Vernuccio F, González F, Farjat AE, Patel BN, Samei E, Henzler T, Schoenberg SO, Marin D. Virtual Unenhanced Images at Dual-Energy CT: Influence on Renal Lesion Characterization. Radiology. 181100. PMID 30860450 DOI: 10.1148/Radiol.2019181100 |
0.41 |
|
2019 |
Robins M, Solomon J, Koweek LMH, Christensen J, Samei E. Validation of lesion simulations in clinical CT data for anonymized chest and abdominal CT databases. Medical Physics. PMID 30703259 DOI: 10.1002/Mp.13412 |
0.442 |
|
2019 |
Euler A, Solomon J, Farjat AE, Nelson RC, Samei E, Marin D. High-Pitch Wide-Coverage Fast-Kilovoltage-Switching Dual-Energy CT: Impact of Pitch on Noise, Spatial Resolution, and Iodine Quantification in a Phantom Study. Ajr. American Journal of Roentgenology. W1-W9. PMID 30645160 DOI: 10.2214/Ajr.18.19851 |
0.377 |
|
2019 |
Ho LM, Samei E, Mazurowski MA, Zheng Y, Allen BC, Nelson RC, Marin D. Can Texture Analysis Be Used to Distinguish Benign From Malignant Adrenal Nodules on Unenhanced CT, Contrast-Enhanced CT, or In-Phase and Opposed-Phase MRI? Ajr. American Journal of Roentgenology. 1-8. PMID 30620676 DOI: 10.2214/Ajr.18.20097 |
0.339 |
|
2019 |
Samei E. Medical Physics 3.0: Ensuring Quality and Safety in Medical Imaging. Health Physics. 116: 247-255. PMID 30585972 DOI: 10.1097/Hp.0000000000001022 |
0.314 |
|
2019 |
Borasi G, Samei E, Bertolini M, Nitrosi A, Tassoni D. Erratum: "Contrast-detail analysis of three flat panel detectors for digital radiography" [Med. Phys., - (2006)]. Medical Physics. 33: 3580. PMID 28525059 DOI: 10.1118/1.2337636 |
0.309 |
|
2019 |
Cook T, Christianson O, Samei E. TU-F-217A-01: Informatics 2: Dose Monitoring. Medical Physics. 39: 3917. PMID 28518697 DOI: 10.1118/1.4735988 |
0.387 |
|
2019 |
McNitt-Gray M, Noo F, Fessier J, Samei E. MO-D-BRA-01: Limits of Dose Reduction in CT: Where are They and How Will We Know When We Get There? Medical Physics. 39: 3868. PMID 28518246 DOI: 10.1118/1.4735793 |
0.446 |
|
2019 |
Samei E, Lo J. Special Section Guest Editorial: Special Section on 3D Printing in Medical Imaging Journal of Medical Imaging. 6: 1. DOI: 10.1117/1.Jmi.6.2.021601 |
0.307 |
|
2018 |
Smith TB, Rubin GD, Solomon J, Harrawood B, Choudhury KR, Samei E. Local complexity metrics to quantify the effect of anatomical noise on detectability of lung nodules in chest CT imaging. Journal of Medical Imaging (Bellingham, Wash.). 5: 045502. PMID 30840750 DOI: 10.1117/1.Jmi.5.4.045502 |
0.315 |
|
2018 |
Robins M, Solomon J, Hoye J, Smith T, Zheng Y, Ebner L, Choudhury KR, Samei E. Interchangeability between real and three-dimensional simulated lung tumors in computed tomography: an interalgorithm volumetry study. Journal of Medical Imaging (Bellingham, Wash.). 5: 035504. PMID 30840716 DOI: 10.1117/1.Jmi.5.3.035504 |
0.332 |
|
2018 |
Gupta RT, Saunders RS, Rosenkrantz AB, Paulson EK, Samei E. The Need for Practical and Accurate Measures of Value for Radiology. Journal of the American College of Radiology : Jacr. PMID 30598415 DOI: 10.1016/J.Jacr.2018.11.013 |
0.302 |
|
2018 |
Abadi E, Harrawood B, Sharma S, Kapadia A, Segars WP, Samei E. DukeSim: A realistic, rapid, and scanner-specific simulation framework in computed tomography. Ieee Transactions On Medical Imaging. PMID 30561344 DOI: 10.1109/Tmi.2018.2886530 |
0.491 |
|
2018 |
Jensen CT, Wagner-Bartak NA, Vu LN, Liu X, Raval B, Martinez D, Wei W, Cheng Y, Samei E, Gupta S. Detection of Colorectal Hepatic Metastases Is Superior at Standard Radiation Dose CT versus Reduced Dose CT. Radiology. 181657. PMID 30480489 DOI: 10.1148/Radiol.2018181657 |
0.452 |
|
2018 |
Winslow J, Zhang Y, Koweek L, Samei E. Dependency of prescribed CT dose on table height, patient size, and localizer acquisition for one clinical MDCT. Physica Medica : Pm : An International Journal Devoted to the Applications of Physics to Medicine and Biology : Official Journal of the Italian Association of Biomedical Physics (Aifb). 55: 56-60. PMID 30471820 DOI: 10.1016/J.Ejmp.2018.10.015 |
0.358 |
|
2018 |
Euler A, Solomon J, Mazurowski MA, Samei E, Nelson RC. How accurate and precise are CT based measurements of iodine concentration? A comparison of the minimum detectable concentration difference among single source and dual source dual energy CT in a phantom study. European Radiology. PMID 30276672 DOI: 10.1007/S00330-018-5736-0 |
0.328 |
|
2018 |
Euler A, Solomon J, FitzGerald PF, Samei E, Nelson RC. Can Realistic Liver Tissue Surrogates Accurately Quantify the Impact of Reduced-kV Imaging on Attenuation and Contrast of Parenchyma and Lesions? Academic Radiology. PMID 30269958 DOI: 10.1016/J.Acra.2018.08.008 |
0.33 |
|
2018 |
Robins M, Solomon J, Richards T, Samei E. 3D task-transfer function representation of the signal transfer properties of low-contrast lesions in FBP- and iterative-reconstructed CT. Medical Physics. PMID 30231193 DOI: 10.1002/Mp.13205 |
0.32 |
|
2018 |
Robins M, Kalpathy-Cramer J, Obuchowski NA, Buckler A, Athelogou M, Jarecha R, Petrick N, Pezeshk A, Sahiner B, Samei E. Evaluation of Simulated Lesions as Surrogates to Clinical Lesions for Thoracic CT Volumetry: The Results of an International Challenge. Academic Radiology. PMID 30219290 DOI: 10.1016/J.Acra.2018.07.022 |
0.36 |
|
2018 |
Mann SD, Joshi A, Shonyo M, Wells JR, Hoye J, Agasthya G, Reiman R, Samei E. Improved Dose Estimates for Fluoroscopically Guided Lumbar Epidural Injections. Pain Medicine (Malden, Mass.). PMID 30215781 DOI: 10.1093/Pm/Pny172 |
0.321 |
|
2018 |
Willis CE, Nishino TK, Wells JR, Ai HA, Wilson JM, Samei E. Automated Quality Control Assessment of Clinical Chest Images. Medical Physics. PMID 30053326 DOI: 10.1002/Mp.13107 |
0.396 |
|
2018 |
Samei E, Grist TM. Why Physics in Medicine? Journal of the American College of Radiology : Jacr. PMID 29784628 DOI: 10.1016/J.Jacr.2018.03.043 |
0.345 |
|
2018 |
Samei E, Jarvinen H, Kortesniemi M, Simantirakis G, Goh C, Wallace A, Vano E, Bejan A, Rehani MM, Vassileva J. Medical imaging dose optimization from ground up: expert opinion of an international summit. Journal of Radiological Protection : Official Journal of the Society For Radiological Protection. PMID 29769433 DOI: 10.1088/1361-6498/Aac575 |
0.422 |
|
2018 |
Ba A, Abbey C, Baek J, Han M, Bouwman RW, Balta C, Brankov J, Massanes F, Gifford HC, Hernandez-Giron I, Veldkamp WJH, Petrov D, Marshall N, Samuelson FW, Zeng R, ... ... Samei E, et al. Inter-laboratory comparison of Channelized Hotelling Observer computation. Medical Physics. PMID 29704868 DOI: 10.1002/Mp.12940 |
0.364 |
|
2018 |
Euler A, Solomon J, Marin D, Nelson RC, Samei E. A Third-Generation Adaptive Statistical Iterative Reconstruction Technique: Phantom Study of Image Noise, Spatial Resolution, Lesion Detectability, and Dose Reduction Potential. Ajr. American Journal of Roentgenology. 1-8. PMID 29702019 DOI: 10.2214/Ajr.17.19102 |
0.421 |
|
2018 |
Abadi E, Segars WP, Sturgeon GM, Roos JE, Ravin CE, Samei E. Modeling Lung Architecture in the XCAT Series of Phantoms: Physiologically Based Airways, Arteries and Veins. Ieee Transactions On Medical Imaging. 37: 693-702. PMID 29533891 DOI: 10.1109/Tmi.2017.2769640 |
0.366 |
|
2018 |
Richards T, Sturgeon GM, Ramirez-Giraldo JC, Rubin GD, Koweek LH, Segars WP, Samei E. Quantification of uncertainty in the assessment of coronary plaque in CCTA through a dynamic cardiac phantom and 3D-printed plaque model. Journal of Medical Imaging (Bellingham, Wash.). 5: 013501. PMID 29376102 DOI: 10.1117/1.Jmi.5.1.013501 |
0.337 |
|
2018 |
Samei E, Robins M, Chen B, Agasthya G. Estimability index for volume quantification of homogeneous spherical lesions in computed tomography. Journal of Medical Imaging (Bellingham, Wash.). 5: 031404. PMID 29250571 DOI: 10.1117/1.Jmi.5.3.031404 |
0.608 |
|
2018 |
Smith TB, Solomon J, Samei E. Estimating detectability index in vivo: development and validation of an automated methodology. Journal of Medical Imaging (Bellingham, Wash.). 5: 031403. PMID 29250570 DOI: 10.1117/1.Jmi.5.3.031403 |
0.418 |
|
2017 |
Samei E, Ikejimba LC, Harrawood BP, Rong J, Cunningham IA, Flynn MJ. Report of AAPM Task Group 162: Software for Planar Image Quality Metrology. Medical Physics. PMID 29220101 DOI: 10.1002/Mp.12718 |
0.371 |
|
2017 |
Abadi E, Sahbaee P, Samei E. Effect of Iodine-based Contrast Material on Radiation Dose at CT. Radiology. 285: 1053-1054. PMID 29155625 DOI: 10.1148/Radiol.2017171523 |
0.361 |
|
2017 |
Järvinen H, Vassileva J, Samei E, Wallace A, Vano E, Rehani M. Patient dose monitoring and the use of diagnostic reference levels for the optimization of protection in medical imaging: current status and challenges worldwide. Journal of Medical Imaging (Bellingham, Wash.). 4: 031214. PMID 29021989 DOI: 10.1117/1.Jmi.4.3.031214 |
0.412 |
|
2017 |
Samei E, Hoeschen C. Special Section Guest Editorial: Visions of Safety: Perspectives on Radiation Exposure and Risk in Medical Imaging. Journal of Medical Imaging (Bellingham, Wash.). 4: 031201. PMID 29021988 DOI: 10.1117/1.Jmi.4.3.031201 |
0.32 |
|
2017 |
Jaffe TA, Tian X, Bashir MR, Marin D, Patel BN, Ho LM, Samei E. Clinically Acceptable Optimized Dose Reduction in Computed Tomographic Imaging of Necrotizing Pancreatitis Using a Noise Addition Software Tool. Journal of Computer Assisted Tomography. PMID 28991065 DOI: 10.1097/Rct.0000000000000684 |
0.43 |
|
2017 |
Winslow J, Zhang Y, Samei E. A method for characterizing and matching CT image quality across CT scanners from different manufacturers. Medical Physics. PMID 28865170 DOI: 10.1002/Mp.12554 |
0.449 |
|
2017 |
Samei E, Tian X, Paul Segars W, Frush DP. Radiation risk index for pediatric CT: a patient-derived metric. Pediatric Radiology. PMID 28856394 DOI: 10.1007/S00247-017-3973-Z |
0.322 |
|
2017 |
Samei E, Li X, Frush DP. Size-based quality-informed framework for quantitative optimization of pediatric CT. Journal of Medical Imaging (Bellingham, Wash.). 4: 031209. PMID 28840168 DOI: 10.1117/1.Jmi.4.3.031209 |
0.427 |
|
2017 |
Segars WP, Tsui BMW, Cai J, Yin FF, Fung GSK, Samei E. Application of the 4D XCAT Phantoms in Biomedical Imaging and Beyond. Ieee Transactions On Medical Imaging. PMID 28809677 DOI: 10.1109/Tmi.2017.2738448 |
0.43 |
|
2017 |
Fu W, Sturgeon GM, Agasthya G, Segars WP, Kapadia AJ, Samei E. Breast dose reduction with organ-based, wide-angle tube current modulated CT. Journal of Medical Imaging (Bellingham, Wash.). 4: 031208. PMID 28804730 DOI: 10.1117/1.Jmi.4.3.031208 |
0.404 |
|
2017 |
Hoye J, Zhang Y, Agasthya G, Sturgeon G, Kapadia A, Segars WP, Samei E. Organ dose variability and trends in tomosynthesis and radiography. Journal of Medical Imaging (Bellingham, Wash.). 4: 031207. PMID 28804729 DOI: 10.1117/1.Jmi.4.3.031207 |
0.344 |
|
2017 |
Robins M, Solomon JB, Sahbaee P, Sedlmair M, Choudhury KR, Pezeshk A, Sahiner B, Samei E. Techniques for virtual lung nodule insertion: volumetric and morphometric comparison of projection-based and image-based methods for quantitative CT. Physics in Medicine and Biology. PMID 28786399 DOI: 10.1088/1361-6560/Aa83F8 |
0.431 |
|
2017 |
Fu W, Marin D, Ramirez-Giraldo JC, Choudhury KR, Solomon J, Schabel C, Patel BN, Samei E. Optimizing window settings for improved presentation of virtual monoenergetic images in dual-energy computed tomography. Medical Physics. PMID 28777467 DOI: 10.1002/Mp.12501 |
0.407 |
|
2017 |
Abadi E, Sanders J, Samei E. Patient-specific quantification of image quality: an automated technique for measuring the distribution of organ Hounsfield units in clinical chest CT images. Medical Physics. PMID 28658516 DOI: 10.1002/Mp.12438 |
0.437 |
|
2017 |
Mileto A, Nelson RC, Larson DG, Samei E, Wilson JM, Christianson O, Marin D, Boll DT. Variability in Radiation Dose From Repeat Identical CT Examinations: Longitudinal Analysis of 2851 Patients Undergoing 12,635 Thoracoabdominal CT Scans in an Academic Health System. Ajr. American Journal of Roentgenology. 1-12. PMID 28350484 DOI: 10.2214/Ajr.16.17070 |
0.366 |
|
2017 |
Lakshmanan MN, Greenberg JA, Samei E, Kapadia AJ. Accuracy assessment and characterization of x-ray coded aperture coherent scatter spectral imaging for breast cancer classification. Journal of Medical Imaging (Bellingham, Wash.). 4: 013505. PMID 28331884 DOI: 10.1117/1.Jmi.4.1.013505 |
0.439 |
|
2017 |
Sahbaee P, Abadi E, Segars WP, Marin D, Nelson RC, Samei E. The Effect of Contrast Medium on Radiation Dose in CT: Part II-A Systematic Evaluation across 58 Patient Models. Radiology. 152852. PMID 28287916 DOI: 10.1148/Radiol.2017152852 |
0.399 |
|
2017 |
Ria F, Wilson JM, Zhang Y, Samei E. Image noise and dose performance across a clinical population: patient size adaptation as a metric of CT performance. Medical Physics. PMID 28235130 DOI: 10.1002/Mp.12172 |
0.464 |
|
2017 |
Solomon J, Marin D, Roy Choudhury K, Patel B, Samei E. Effect of Radiation Dose Reduction and Reconstruction Algorithm on Image Noise, Contrast, Resolution, and Detectability of Subtle Hypoattenuating Liver Lesions at Multidetector CT: Filtered Back Projection versus a Commercial Model-based Iterative Reconstruction Algorithm. Radiology. 161736. PMID 28170300 DOI: 10.1148/Radiol.2017161736 |
0.444 |
|
2017 |
Sanders J, Tian X, Segars WP, Boone J, Samei E. Automated, patient-specific estimation of regional imparted energy and dose from tube current modulated computed tomography exams across 13 protocols. Journal of Medical Imaging (Bellingham, Wash.). 4: 013503. PMID 28149922 DOI: 10.1117/1.Jmi.4.1.013503 |
0.393 |
|
2017 |
Zhang Y, Smitherman C, Samei E. Size Specific Optimization of CT Protocols Based on Minimum Detectability. Medical Physics. PMID 28122119 DOI: 10.1002/Mp.12125 |
0.429 |
|
2017 |
Sahbaee P, Segars WP, Marin D, Nelson RC, Samei E. The Effect of Contrast Material on Radiation Dose at CT: Part I-Incorporation of Contrast Material Dynamics in Anthropomorphic Phantoms. Radiology. 152851. PMID 28092496 DOI: 10.1148/Radiol.2016152851 |
0.349 |
|
2017 |
Zhao C, Solomon J, Sturgeon GM, Gehm ME, Catenacci M, Wiley BJ, Samei E, Lo JY. Third generation anthropomorphic physical phantom for mammography and DBT: incorporating voxelized 3D printing and uniform chest wall QC region Proceedings of Spie. 10132. DOI: 10.1117/12.2256091 |
0.355 |
|
2017 |
Zheng Y, Solomon J, Choudhury K, Marin D, Samei E. Accuracy and variability of texture-based radiomics features of lung lesions across CT imaging conditions Proceedings of Spie. 10132. DOI: 10.1117/12.2255806 |
0.425 |
|
2017 |
Fu W, Sturgeon GM, Agasthya G, Segars WP, Kapadia AJ, Samei E. Estimation of breast dose reduction potential for organ-based tube current modulated CT with wide dose reduction arc Proceedings of Spie. 10132: 1013246. DOI: 10.1117/12.2255797 |
0.378 |
|
2017 |
Ria F, Wilson J, Zhang Y, Samei E. Adaptability index: quantifying CT tube current modulation performance from dose and quality informatics Proceedings of Spie. 10132. DOI: 10.1117/12.2255631 |
0.461 |
|
2017 |
Richards T, Sturgeon GM, Ramirez-Giraldo JC, Rubin G, Segars P, Samei E. Quantification of the uncertainty in coronary CTA plaque measurements using dynamic cardiac phantom and 3D-printed plaque models Proceedings of Spie. 10132. DOI: 10.1117/12.2255592 |
0.329 |
|
2017 |
Hoye J, Zhang Y, Agasthya G, Sturgeon G, Kapadia A, Segars WP, Samei E. An atlas-based organ dose estimator for tomosynthesis and radiography Proceedings of Spie. 10132: 1013204. DOI: 10.1117/12.2255583 |
0.338 |
|
2017 |
Sturgeon GM, Richards TW, Samei E, Segars WP. Improved virtual cardiac phantom with variable diastolic filling rates and coronary artery velocities Proceedings of Spie. 10132. DOI: 10.1117/12.2255572 |
0.301 |
|
2017 |
Zhao A, Santana M, Samei E, Lo J. Comparison of effects of dose on image quality in digital breast tomosynthesis across multiple vendors Proceedings of Spie. 10132. DOI: 10.1117/12.2255570 |
0.432 |
|
2017 |
Smith TB, Solomon J, Samei E. In-vivo detectability index: development and validation of an automated methodology Proceedings of Spie. 10132: 1013255. DOI: 10.1117/12.2255411 |
0.437 |
|
2017 |
Flohr TG, Lo JY, Schmidt TG, Abadi E, Sturgeon GM, Agasthya G, Harrawood B, Hoeschen C, Kapadia A, Segars WP, Samei E. Airways, vasculature, and interstitial tissue: anatomically informed computational modeling of human lungs for virtual clinical trials Proceedings of Spie. 10132. DOI: 10.1117/12.2254739 |
0.391 |
|
2017 |
Robins M, Solomon J, Hoye J, Smith T, Ebner L, Samei E. Inter-algorithm lesion volumetry comparison of real and 3D simulated lung lesions in CT Proceedings of Spie. 10132. DOI: 10.1117/12.2254219 |
0.361 |
|
2017 |
Solomon J, Rubin G, Smith T, Harrawood B, Choudhury KR, Samei E. Development of local complexity metrics to quantify the effect of anatomical noise on detectability of lung nodules in chest CT imaging Proceedings of Spie. 10136. DOI: 10.1117/12.2254044 |
0.381 |
|
2016 |
Wilson JM, Samei E. SU-F-R-11: Designing Quality and Safety Informatics Through Implementation of a CT Radiation Dose Monitoring Program. Medical Physics. 43: 3375. PMID 28048918 DOI: 10.1118/1.4955783 |
0.351 |
|
2016 |
Ria F, Wilson JM, Guntzer P, Zanca F, Samei E. SU-F-I-48: Variability in CT Scanning Over-Range Across Clinical Operation. Medical Physics. 43: 3397. PMID 28048214 DOI: 10.1118/1.4955876 |
0.333 |
|
2016 |
Sanders J, Ding A, Samei E. TH-CD-207B-02: An Automated Technique to Measure Spatial Resolution in Clinical CT Images: Application to Patient Data. Medical Physics. 43: 3889. PMID 28047694 DOI: 10.1118/1.4958208 |
0.364 |
|
2016 |
Sanders J, Abadi E, Meng B, Samei E. SU-F-I-45: An Automated Technique to Measure Image Contrast in Clinical CT Images. Medical Physics. 43: 3397. PMID 28047457 DOI: 10.1118/1.4955873 |
0.44 |
|
2016 |
Sanders J, Tian X, Segars P, Boone J, Samei E. TU-H-207A-09: An Automated Technique for Estimating Patient-Specific Regional Imparted Energy and Dose From TCM CT Exams Across 13 Protocols. Medical Physics. 43: 3773. PMID 28047247 DOI: 10.1118/1.4957645 |
0.349 |
|
2016 |
Richards T, Mann S, Samei E. TU-FG-209-06: Quantitative Evaluation of the Temporal Performance of Clinical Fluoroscopic Imaging Systems: The Temporal Modulation Transfer Function (TMTF). Medical Physics. 43: 3761-3762. PMID 28046623 DOI: 10.1118/1.4957576 |
0.337 |
|
2016 |
Mann S, Nelson J, Samei E. TU-H-206-01: An Automated Approach for Identifying Geometric Distortions in Gamma Cameras. Medical Physics. 43: 3773-3774. PMID 28046574 DOI: 10.1118/1.4957646 |
0.365 |
|
2016 |
Abadi E, Sanders J, Agasthya G, Segars P, Samei E. TH-AB-207A-01: Contrast-Enhanced CT: Correlation of Radiation Dose and Biological Effect. Medical Physics. 43: 3859. PMID 28046510 DOI: 10.1118/1.4958077 |
0.359 |
|
2016 |
Fu W, Tian X, Sturgeon G, Agasthya G, Segars WP, Goodsitt MM, Kazerooni EA, Samei E. CT Breast Dose Reduction with the Use of Breast Positioning and Organ-Based Tube Current Modulation. Medical Physics. PMID 28032894 DOI: 10.1002/Mp.12076 |
0.351 |
|
2016 |
Bellini D, Ramirez-Giraldo JC, Bibbey A, Solomon J, Hurwitz LM, Farjat A, Mileto A, Samei E, Marin D. Dual-Source Single-Energy Multidetector CT Used to Obtain Multiple Radiation Exposure Levels within the Same Patient: Phantom Development and Clinical Validation. Radiology. 161233. PMID 27935766 DOI: 10.1148/Radiol.2016161233 |
0.474 |
|
2016 |
Solomon J, Ba A, Bochud F, Samei E. Comparison of low-contrast detectability between two CT reconstruction algorithms using voxel-based 3D printed textured phantoms. Medical Physics. 43: 6497. PMID 27908164 DOI: 10.1118/1.4967478 |
0.386 |
|
2016 |
Sanders J, Hurwitz L, Samei E. Patient-specific quantification of image quality: An automated method for measuring spatial resolution in clinical CT images. Medical Physics. 43: 5330. PMID 27782718 DOI: 10.1118/1.4961984 |
0.441 |
|
2016 |
Ikejimba LC, Glick SJ, Choudhury KR, Samei E, Lo JY. Assessing task performance in FFDM, DBT, and synthetic mammography using uniform and anthropomorphic physical phantoms. Medical Physics. 43: 5593. PMID 27782687 DOI: 10.1118/1.4962475 |
0.354 |
|
2016 |
Solomon J, Samei E. Correlation between human detection accuracy and observer model-based image quality metrics in computed tomography. Journal of Medical Imaging (Bellingham, Wash.). 3: 035506. PMID 27704032 DOI: 10.1117/1.Jmi.3.3.035506 |
0.407 |
|
2016 |
Kiarashi N, Nolte LW, Lo JY, Segars WP, Ghate SV, Solomon JB, Samei E. Impact of breast structure on lesion detection in breast tomosynthesis, a simulation study. Journal of Medical Imaging (Bellingham, Wash.). 3: 035504. PMID 27660807 DOI: 10.1117/1.Jmi.3.3.035504 |
0.373 |
|
2016 |
Lin Y, Samei E. Development and validation of a segmentation-free polyenergetic algorithm for dynamic perfusion computed tomography. Journal of Medical Imaging (Bellingham, Wash.). 3: 033503. PMID 27610396 DOI: 10.1117/1.Jmi.3.3.033503 |
0.396 |
|
2016 |
Nelson JS, Wells JR, Baker JA, Samei E. How does c-view image quality compare with conventional 2D FFDM? Medical Physics. 43: 2538. PMID 27147364 DOI: 10.1118/1.4947293 |
0.418 |
|
2016 |
Sturgeon GM, Kiarashi N, Lo JY, Samei E, Segars WP. Finite-element modeling of compression and gravity on a population of breast phantoms for multimodality imaging simulation. Medical Physics. 43: 2207. PMID 27147333 DOI: 10.1118/1.4945275 |
0.397 |
|
2016 |
Tian X, Segars WP, Dixon RL, Samei E. Convolution-based estimation of organ dose in tube current modulated CT. Physics in Medicine and Biology. 61: 3935-3954. PMID 27119974 DOI: 10.1088/0031-9155/61/10/3935 |
0.38 |
|
2016 |
Marin D, Ramirez-Giraldo JC, Gupta S, Fu W, Stinnett SS, Mileto A, Bellini D, Patel B, Samei E, Nelson RC. Effect of a Noise-Optimized Second-Generation Monoenergetic Algorithm on Image Noise and Conspicuity of Hypervascular Liver Tumors: An In Vitro and In Vivo Study. Ajr. American Journal of Roentgenology. 1-11. PMID 27058192 DOI: 10.2214/Ajr.15.15512 |
0.352 |
|
2016 |
Ikejimba L, Lo JY, Chen Y, Oberhofer N, Kiarashi N, Samei E. A quantitative metrology for performance characterization of five breast tomosynthesis systems based on an anthropomorphic phantom. Medical Physics. 43: 1627. PMID 27036562 DOI: 10.1118/1.4943373 |
0.347 |
|
2016 |
Lakshmanan MN, Greenberg JA, Samei E, Kapadia AJ. Design and implementation of coded aperture coherent scatter spectral imaging of cancerous and healthy breast tissue samples. Journal of Medical Imaging (Bellingham, Wash.). 3: 013505. PMID 26962543 DOI: 10.1117/1.Jmi.3.1.013505 |
0.399 |
|
2016 |
Tian X, Yin Z, De Man B, Samei E. Estimation of Radiation Dose in CT Based on Projection Data. Journal of Digital Imaging. PMID 26893140 DOI: 10.1007/S10278-016-9869-X |
0.369 |
|
2016 |
Sahbaee P, Segars PP, Marin D, Nelson R, Samei E. Determination of contrast media administration to achieve a targeted contrast enhancement in computed tomography. Journal of Medical Imaging (Bellingham, Wash.). 3: 013501. PMID 26835498 DOI: 10.1117/1.Jmi.3.1.013501 |
0.368 |
|
2016 |
Tian X, Samei E. Accurate assessment and prediction of noise in clinical CT images. Medical Physics. 43: 475. PMID 26745940 DOI: 10.1118/1.4938588 |
0.409 |
|
2016 |
Erickson DW, Wells JR, Sturgeon GM, Samei E, Dobbins JT, Segars WP, Lo JY. Population of 224 realistic human subject-based computational breast phantoms. Medical Physics. 43: 23. PMID 26745896 DOI: 10.1118/1.4937597 |
0.314 |
|
2016 |
Robins M, Solomon J, Samei E. TH-CD-207B-04: Is TTF a True Representation of the Sharpness Property of a Non-Linear CT System? Medical Physics. 43: 3889-3889. DOI: 10.1118/1.4958210 |
0.417 |
|
2016 |
Samei E. WE-B-BRC-03: Risk in the Context of Medical Imaging Medical Physics. 43: 3807-3807. DOI: 10.1118/1.4957800 |
0.325 |
|
2016 |
Winslow J, Zhang Y, Samei E. TU-H-207A-05: Automated Early Identification of An Excessive Air-In-Oil X-Ray Tube Artifact That Mimics Acute Cerebral Infarct Medical Physics. 43: 3772-3772. DOI: 10.1118/1.4957641 |
0.385 |
|
2016 |
Samei E. TU-D-207A-02: Quantitative Assessment of CT Systems with Iterative Image Reconstruction Algorithms Medical Physics. 43: 3747-3748. DOI: 10.1118/1.4957495 |
0.462 |
|
2016 |
Solomon J, Zhang Y, Marin D, Samei E. SU-G-206-13: Validating Dose Split: A Method to Image the Same Patient at Multiple Doses with a Single CT Acquisition Medical Physics. 43: 3642-3642. DOI: 10.1118/1.4956954 |
0.466 |
|
2016 |
Sikaria D, Musinsky S, Sturgeon GM, Solomon J, Diao A, Gehm ME, Samei E, Glick SJ, Lo JY. Second generation anthropomorphic physical phantom for mammography and DBT: Incorporating voxelized 3D printing and inkjet printing of iodinated lesion inserts Proceedings of Spie. 9783: 978360. DOI: 10.1117/12.2217667 |
0.35 |
|
2016 |
Solomon J, Ba A, Diao A, Lo J, Bier E, Bochud F, Gehm M, Samei E. Design, fabrication, and implementation of voxel-based 3D printed textured phantoms for task-based image quality assessment in CT Proceedings of Spie. 9783: 978328. DOI: 10.1117/12.2217463 |
0.49 |
|
2016 |
Fu W, Tian X, Sahbaee P, Zhang Y, Segars WP, Samei E. Organ dose conversion coefficients for tube current modulated CT protocols for an adult population Proceedings of Spie. 9783. DOI: 10.1117/12.2217271 |
0.355 |
|
2016 |
Fu W, Tian X, Sturgeon G, Agasthya G, Segars WP, Goodsitt MM, Kazerooni EA, Samei E. Estimation of breast dose saving potential using a breast positioning technique for organ-based tube current modulated CT Proceedings of Spie. 9783. DOI: 10.1117/12.2217239 |
0.363 |
|
2016 |
Becchetti MF, Solomon JB, Segars WP, Samei E. Synthesized interstitial lung texture for use in anthropomorphic computational phantoms Proceedings of Spie. 9783. DOI: 10.1117/12.2217135 |
0.439 |
|
2016 |
Robins M, Solomon J, Sahbaee P, Samei E. Development and comparison of projection and image space 3D nodule insertion techniques Proceedings of Spie. 9783. DOI: 10.1117/12.2216930 |
0.44 |
|
2016 |
Ikejimba L, Glick SJ, Samei E, Lo JY. Comparison of model and human observer performance in FFDM, DBT, and synthetic mammography Proceedings of Spie. 9783: 978325. DOI: 10.1117/12.2216858 |
0.378 |
|
2016 |
Sahbaee P, Abadi E, Sanders J, Becchetti M, Zhang Y, Agasthya G, Segars P, Samei E. A technique for multi-dimensional optimization of radiation dose, contrast dose, and image quality in CT imaging Proceedings of Spie. 9783. DOI: 10.1117/12.2216516 |
0.481 |
|
2016 |
Sahbaee P, Robins M, Solomon J, Samei E. Development of a Hausdorff distance based 3D quantification technique to evaluate the CT imaging system impact on depiction of lesion morphology Proceedings of Spie. 9783. DOI: 10.1117/12.2216503 |
0.423 |
|
2016 |
Lakshmanan MN, Morris RE, Greenberg JA, Samei E, Kapadia AJ. Coded aperture coherent scatter imaging for breast cancer detection: a Monte Carlo evaluation Proceedings of Spie. 9783: 978321. DOI: 10.1117/12.2216482 |
0.406 |
|
2016 |
Sanders JW, Tian X, Segars WP, Boone JM, Samei E. An automated technique for estimating patient-specific regional imparted energy and dose in TCM CT exams Proceedings of Spie. 9783. DOI: 10.1117/12.2216413 |
0.378 |
|
2015 |
Solomon J, Mileto A, Nelson RC, Roy Choudhury K, Samei E. Quantitative Features of Liver Lesions, Lung Nodules, and Renal Stones at Multi-Detector Row CT Examinations: Dependency on Radiation Dose and Reconstruction Algorithm. Radiology. 150892. PMID 26624973 DOI: 10.1148/Radiol.2015150892 |
0.418 |
|
2015 |
Lakshmanan MN, Harrawood BP, Samei E, Kapadia AJ. Volumetric x-ray coherent scatter imaging of cancer in resected breast tissue: a Monte Carlo study using virtual anthropomorphic phantoms. Physics in Medicine and Biology. 60: 6355-70. PMID 26237265 DOI: 10.1088/0031-9155/60/16/6355 |
0.361 |
|
2015 |
Solomon J, Wilson J, Samei E. Characteristic image quality of a third generation dual-source MDCT scanner: Noise, resolution, and detectability. Medical Physics. 42: 4941-53. PMID 26233220 DOI: 10.1118/1.4923172 |
0.444 |
|
2015 |
Segars WP, Norris H, Sturgeon GM, Zhang Y, Bond J, Minhas A, Tward DJ, Ratnanather JT, Miller MI, Frush D, Samei E. The development of a population of 4D pediatric XCAT phantoms for imaging research and optimization. Medical Physics. 42: 4719. PMID 26233199 DOI: 10.1117/12.2043777 |
0.346 |
|
2015 |
Kiarashi N, Nolte AC, Sturgeon GM, Segars WP, Ghate SV, Nolte LW, Samei E, Lo JY. Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data. Medical Physics. 42: 4116-26. PMID 26133612 DOI: 10.1118/1.4919771 |
0.356 |
|
2015 |
Sahbaee P, Zhang Y, Solomon J, Becchetti M, Segars P, Samei E. TU-G-204-04: A Unified Strategy for Bi-Factorial Optimization of Radiation Dose and Contrast Dose in CT Imaging. Medical Physics. 42: 3633. PMID 26129067 DOI: 10.1118/1.4925768 |
0.484 |
|
2015 |
Christianson O, Winslow J, Frush DP, Samei E. Automated Technique to Measure Noise in Clinical CT Examinations. Ajr. American Journal of Roentgenology. 205: W93-9. PMID 26102424 DOI: 10.2214/Ajr.14.13613 |
0.356 |
|
2015 |
Brinkley MF, Ramirez-Giraldo JC, Samei E, Frush DJ, Choudhury KR, Wilson JM, Christianson OI, Frush DP. Effects of automatic tube potential selection on radiation dose index, image quality, and lesion detectability in pediatric abdominopelvic CT and CTA: a phantom study. European Radiology. PMID 25991484 DOI: 10.1007/S00330-015-3817-X |
0.438 |
|
2015 |
Saiprasad G, Filliben J, Peskin A, Siegel E, Chen J, Trimble C, Yang Z, Christianson O, Samei E, Krupinski E, Dima A. Evaluation of Low-Contrast Detectability of Iterative Reconstruction across Multiple Institutions, CT Scanner Manufacturers, and Radiation Exposure Levels. Radiology. 277: 124-33. PMID 25989480 DOI: 10.1148/Radiol.2015141260 |
0.445 |
|
2015 |
Samei E, Thompson J, Richard S, Bowsher J. A Case for Wide-Angle Breast Tomosynthesis. Academic Radiology. 22: 860-9. PMID 25920335 DOI: 10.1016/J.Acra.2015.02.015 |
0.361 |
|
2015 |
Samei E, Zhang Y, Christianson O. Comment on “Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus” [Med. Phys. 41(2), 023901 (12pp.) (2014)]. Medical Physics. 42: 2094. PMID 25832099 DOI: 10.1118/1.4914374 |
0.343 |
|
2015 |
Tian X, Li X, Segars WP, Frush DP, Samei E. Prospective estimation of organ dose in CT under tube current modulation. Medical Physics. 42: 1575-85. PMID 25832048 DOI: 10.1118/1.4907955 |
0.41 |
|
2015 |
Solomon J, Mileto A, Ramirez-Giraldo JC, Samei E. Diagnostic Performance of an Advanced Modeled Iterative Reconstruction Algorithm for Low-Contrast Detectability with a Third-Generation Dual-Source Multidetector CT Scanner: Potential for Radiation Dose Reduction in a Multireader Study. Radiology. 275: 735-45. PMID 25751228 DOI: 10.1148/Radiol.15142005 |
0.409 |
|
2015 |
Wilson JM, Samei E. Implementation of the ACR Dose Index Registry. Journal of the American College of Radiology : Jacr. 12: 312-3. PMID 25743926 DOI: 10.1016/J.Jacr.2014.11.019 |
0.355 |
|
2015 |
Christianson O, Chen JJ, Yang Z, Saiprasad G, Dima A, Filliben JJ, Peskin A, Trimble C, Siegel EL, Samei E. An Improved Index of Image Quality for Task-based Performance of CT Iterative Reconstruction across Three Commercial Implementations. Radiology. 275: 725-34. PMID 25686365 DOI: 10.1148/Radiol.15132091 |
0.468 |
|
2015 |
Samei E, Richard S. Assessment of the dose reduction potential of a model-based iterative reconstruction algorithm using a task-based performance metrology. Medical Physics. 42: 314-23. PMID 25563271 DOI: 10.1118/1.4903899 |
0.465 |
|
2015 |
Tian X, Segars P, Andersson J, Pavlicek W, Samei E. TH-EF-BRA-07: A Reference Organ Dose Database for Body CT Examination Based On AAPM 246 Medical Physics. 42: 3746-3746. DOI: 10.1118/1.4926314 |
0.385 |
|
2015 |
Wells J, Christensen J, Samei E. TH-AB-201-12: A Consumer Report for Mobile Digital Radiography: A Holistic Comparative Evaluation Across Four Systems Medical Physics. 42: 3720-3720. DOI: 10.1118/1.4926196 |
0.398 |
|
2015 |
Willis C, Willis C, Nishino T, Wells J, Wilson J, Samei E. WE-G-204-09: Medical Physics 2.0 in Practice: Automated QC Assessment of Clinical Chest Images Medical Physics. 42: 3695-3696. DOI: 10.1118/1.4926093 |
0.409 |
|
2015 |
Wells J, Zhang L, Samei E. WE-G-204-07: Automated Characterization of Perceptual Quality of Clinical Chest Radiographs: Improvements in Lung, Spine, and Hardware Detection Medical Physics. 42: 3695-3695. DOI: 10.1118/1.4926091 |
0.367 |
|
2015 |
Nelson J, Wells J, Samei E. TU-CD-207-08: Intrinsic Image Quality Comparison of Synthesized 2-D and FFDM Images Medical Physics. 42: 3611-3612. DOI: 10.1118/1.4925627 |
0.433 |
|
2015 |
Becchetti M, Tian X, Segars P, Samei E. MO-F-CAMPUS-I-03: GPU Accelerated Monte Carlo Technique for Fast Concurrent Image and Dose Simulation Medical Physics. 42: 3583-3583. DOI: 10.1118/1.4925488 |
0.445 |
|
2015 |
Ikejimba L, Chen Y, Oberhofer N, Kiarashi N, Lo JY, Samei E. A quantitative metrology for performance characterization of breast tomosynthesis systems based on an anthropomorphic phantom Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9412. DOI: 10.1117/12.2082594 |
0.335 |
|
2015 |
Kiarashi N, Nolte LW, Lo JY, Segars WP, Ghate SV, Samei E. The impact of breast structure on lesion detection in breast tomosynthesis Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9412. DOI: 10.1117/12.2082473 |
0.364 |
|
2015 |
Lakshmanan MN, Greenberg JA, Samei E, Kapadia AJ. Experimental implementation of coded aperture coherent scatter spectral imaging of cancerous and healthy breast tissue samples Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9412. DOI: 10.1117/12.2082318 |
0.396 |
|
2015 |
Sahbaee P, Li Y, Segars P, Marin D, Nelson R, Samei E. Determination of contrast media administration to achieve a targeted contrast enhancement in CT Proceedings of Spie. 9412: 941205. DOI: 10.1117/12.2082261 |
0.364 |
|
2015 |
Solomon J, Samei E. What observer models best reflect low-contrast detectability in CT? Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9416. DOI: 10.1117/12.2081655 |
0.447 |
|
2015 |
Solomon J, Mileto A, Ramirez-Giraldo JC, Samei E. A multireader diagnostic performance study of low-contrast detectability on a third-generation dual-source CT scanner: Filtered back projection versus advanced modeled iterative reconstruction Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9416. DOI: 10.1117/12.2081647 |
0.488 |
|
2014 |
Winslow J, Christianson O, Samei E. SU-F-18C-07: Automated CT QC Program with Analytics, Archival, and Notification Capabilities. Medical Physics. 41: 404. PMID 28038307 DOI: 10.1118/1.4889092 |
0.331 |
|
2014 |
Nelson J, Christianson O, Samei E. SU-C-9A-02: Structured Noise Index as An Automated Quality Control for Nuclear Medicine: A Two Year Experience. Medical Physics. 41: 104. PMID 28037709 DOI: 10.1118/1.4887843 |
0.364 |
|
2014 |
Samei E, Hangiandreou N, Nelson J. TH-E-9A-01: Medical Physics 1.0 to 2.0, Session 4: Computed Tomography, Ultrasound and Nuclear Medicine. Medical Physics. 41: 574-575. PMID 28037388 DOI: 10.1118/1.4889842 |
0.443 |
|
2014 |
Wells J, Wilson J, Zhang Y, Samei E, Ravin CE. SU-E-I-94: Automated Image Quality Assessment of Radiographic Systems Using An Anthropomorphic Phantom. Medical Physics. 41: 152. PMID 28037302 DOI: 10.1118/1.4888044 |
0.426 |
|
2014 |
Chen G, Pan X, Stayman J, Samei E. MO-C-18A-01: Advances in Model-Based 3D Image Reconstruction. Medical Physics. 41: 416-417. PMID 28036883 DOI: 10.1118/1.4889136 |
0.466 |
|
2014 |
Winslow J, Wilson J, Christianson O, Samei E. WE-D-18A-02: Performance Evaluation of Automatic Exposure Control (AEC) Across 12 Clinical CT Systems. Medical Physics. 41: 498. PMID 28036597 DOI: 10.1118/1.4889411 |
0.33 |
|
2014 |
Rehani M, Samei E, Morgan W, Shore R, Goske M. MO-C-18C-01: Radiation Risks at Level of Few CT Scans: How Real?- Science to Practice. Medical Physics. 41: 417. PMID 28036421 DOI: 10.1118/1.4889137 |
0.307 |
|
2014 |
Chen B, Ramirez Giraldo JC, Solomon J, Samei E. Evaluating iterative reconstruction performance in computed tomography. Medical Physics. 41: 121913. PMID 25471973 DOI: 10.1118/1.4901670 |
0.546 |
|
2014 |
Segars WP, Rybicki K, Norris H, Frush D, Samei E. Organ localization: toward prospective patient-specific organ dosimetry in computed tomography. Medical Physics. 41: 121908. PMID 25471968 DOI: 10.1118/1.4901554 |
0.394 |
|
2014 |
Samei E, Lin Y, Choudhury KR, McAdams HP. Automated characterization of perceptual quality of clinical chest radiographs: validation and calibration to observer preference. Medical Physics. 41: 111918. PMID 25370651 DOI: 10.1118/1.4899183 |
0.38 |
|
2014 |
Solomon J, Samei E. A generic framework to simulate realistic lung, liver and renal pathologies in CT imaging. Physics in Medicine and Biology. 59: 6637-57. PMID 25325156 DOI: 10.1088/0031-9155/59/21/6637 |
0.397 |
|
2014 |
Samei E. Pros and cons of organ shielding for CT imaging. Pediatric Radiology. 44: 495-500. PMID 25304710 DOI: 10.1007/S00247-014-3084-Z |
0.462 |
|
2014 |
Samei E, Tian X, Segars WP. Determining organ dose: the holy grail. Pediatric Radiology. 44: 460-7. PMID 25304705 DOI: 10.1007/S00247-014-3117-7 |
0.378 |
|
2014 |
Solomon J, Samei E. Quantum noise properties of CT images with anatomical textured backgrounds across reconstruction algorithms: FBP and SAFIRE. Medical Physics. 41: 091908. PMID 25186395 DOI: 10.1118/1.4893497 |
0.394 |
|
2014 |
Samei E, Richard S, Lurwitz L. Model-based CT performance assessment and optimization for iodinated and noniodinated imaging tasks as a function of kVp and body size. Medical Physics. 41: 081910. PMID 25086541 DOI: 10.1118/1.4890082 |
0.443 |
|
2014 |
Li X, Segars WP, Samei E. The impact on CT dose of the variability in tube current modulation technology: a theoretical investigation. Physics in Medicine and Biology. 59: 4525-48. PMID 25069102 DOI: 10.1088/0031-9155/59/16/4525 |
0.378 |
|
2014 |
Sahbaee P, Segars WP, Samei E. Patient-based estimation of organ dose for a population of 58 adult patients across 13 protocol categories. Medical Physics. 41: 072104. PMID 24989399 DOI: 10.1118/1.4883778 |
0.346 |
|
2014 |
Chen B, Christianson O, Wilson JM, Samei E. Assessment of volumetric noise and resolution performance for linear and nonlinear CT reconstruction methods. Medical Physics. 41: 071909. PMID 24989387 DOI: 10.1118/1.4881519 |
0.612 |
|
2014 |
Lin Y, Ramirez-Giraldo JC, Gauthier DJ, Stierstorfer K, Samei E. An angle-dependent estimation of CT x-ray spectrum from rotational transmission measurements. Medical Physics. 41: 062104. PMID 24877831 DOI: 10.1118/1.4876380 |
0.385 |
|
2014 |
Ikejimba LC, Kiarashi N, Ghate SV, Samei E, Lo JY. Task-based strategy for optimized contrast enhanced breast imaging: analysis of six imaging techniques for mammography and tomosynthesis. Medical Physics. 41: 061908. PMID 24877819 DOI: 10.1117/12.913377 |
0.454 |
|
2014 |
Mileto A, Nelson RC, Samei E, Jaffe TA, Paulson EK, Barina A, Choudhury KR, Wilson JM, Marin D. Impact of dual-energy multi-detector row CT with virtual monochromatic imaging on renal cyst pseudoenhancement: in vitro and in vivo study. Radiology. 272: 767-76. PMID 24844472 DOI: 10.1148/Radiol.14132856 |
0.39 |
|
2014 |
Kiarashi N, Lo JY, Lin Y, Ikejimba LC, Ghate SV, Nolte LW, Dobbins JT, Segars WP, Samei E. Development and application of a suite of 4-D virtual breast phantoms for optimization and evaluation of breast imaging systems. Ieee Transactions On Medical Imaging. 33: 1401-9. PMID 24691118 DOI: 10.1109/Tmi.2014.2312733 |
0.406 |
|
2014 |
Lin Y, Samei E. A fast poly-energetic iterative FBP algorithm. Physics in Medicine and Biology. 59: 1655-78. PMID 24614805 DOI: 10.1088/0031-9155/59/7/1655 |
0.381 |
|
2014 |
Norris H, Zhang Y, Bond J, Sturgeon GM, Minhas A, Tward DJ, Ratnanather JT, Miller MI, Frush D, Samei E, Segars WP. A set of 4D pediatric XCAT reference phantoms for multimodality research. Medical Physics. 41: 033701. PMID 24593745 DOI: 10.1118/1.4864238 |
0.417 |
|
2014 |
Zhang Y, Li X, Segars WP, Samei E. Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus. Medical Physics. 41: 023901. PMID 24506654 DOI: 10.1118/1.4859315 |
0.434 |
|
2014 |
Lin Y, Samei E. An efficient polyenergetic SART (pSART) reconstruction algorithm for quantitative myocardial CT perfusion. Medical Physics. 41: 021911. PMID 24506632 DOI: 10.1118/1.4863481 |
0.409 |
|
2014 |
Nelson JS, Christianson OI, Harkness BA, Madsen MT, Mah E, Thomas SR, Zaidi H, Samei E. Improved nuclear medicine uniformity assessment with noise texture analysis. Journal of Nuclear Medicine : Official Publication, Society of Nuclear Medicine. 55: 169-74. PMID 24212975 DOI: 10.2967/Jnumed.113.125450 |
0.362 |
|
2014 |
Tian X, Li X, Segars WP, Paulson EK, Frush DP, Samei E. Pediatric chest and abdominopelvic CT: organ dose estimation based on 42 patient models. Radiology. 270: 535-47. PMID 24126364 DOI: 10.1148/Radiol.13122617 |
0.389 |
|
2014 |
Christianson O, Winslow J, Samei E. TH-C-18A-06: Combined CT Image Quality and Radiation Dose Monitoring Program Based On Patient Data to Assess Consistency of Clinical Imaging Across Scanner Models Medical Physics. 41: 558-558. DOI: 10.1118/1.4889630 |
0.493 |
|
2014 |
Samei E, Pfeiffer D, Frey G, Krupinski E, Pizzutiello R, Carson P, Mahesh M, Hangiandreou N, Jordan D, Dixon R. TU-C-18C-01: Medical Physics 1.0 to 2.0: Introduction and Panel Discussion Medical Physics. 41: 461-462. DOI: 10.1118/1.4889289 |
0.356 |
|
2014 |
Sahbaee P, Samei E, Segars W. MO-E-17A-02: Incorporation of Contrast Medium Dynamics in Anthropomorphic Phantoms: The Advent of 5D XCAT Models Medical Physics. 41: 424-424. DOI: 10.1118/1.4889154 |
0.387 |
|
2014 |
Smitherman C, Chen B, Samei E. SU-F-18C-01: Minimum Detectability Analysis for Comprehensive Sized Based Optimization of Image Quality and Radiation Dose Across CT Protocols Medical Physics. 41: 402-403. DOI: 10.1118/1.4889085 |
0.481 |
|
2014 |
Winslow J, Hurwitz L, Christianson O, Samei E. SU-E-I-91: Reproducibility in Prescribed Dose in AEC CT Scans Due to Table Height, Patient Size, and Localizer Acquisition Order Medical Physics. 41: 151-151. DOI: 10.1118/1.4888041 |
0.408 |
|
2014 |
Sahbaee P, Samei E, Segars W. SU-C-12A-03: The Impact of Contrast Medium On Radiation Dose in CT: A Systematic Evaluation Across 58 Patient Models Medical Physics. 41: 106-106. DOI: 10.1118/1.4887851 |
0.421 |
|
2014 |
Tian X, Wilson J, Frush D, Samei E. Prospective optimization of CT under tube current modulation: II. image quality Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9033. DOI: 10.1117/12.2044013 |
0.379 |
|
2014 |
Chen B, Wilson J, Samei E. A refined methodology for modeling volume quantification performance in CT Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9033. DOI: 10.1117/12.2044004 |
0.618 |
|
2014 |
Lin Y, Choudhury KR, McAdams HP, Foos DH, Samei E. Validation of an image-based technique to assess the perceptual quality of clinical chest radiographs with an observer study Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9033. DOI: 10.1117/12.2043993 |
0.403 |
|
2014 |
Segars WP, Veress AI, Wells JR, Sturgeon GM, Kiarashi N, Lo JY, Samei E, Dobbins JT. Population of 100 realistic, patient-based computerized breast phantoms for multi-modality imaging research Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9033. DOI: 10.1117/12.2043868 |
0.392 |
|
2014 |
Tian X, Li X, Segars WP, Frush D, Samei E. Prospective optimization of CT under Tube current modulation: I. organ dose Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9033. DOI: 10.1117/12.2043858 |
0.382 |
|
2014 |
Lakshmanan MN, Kapadia AJ, Harrawood BP, Brady D, Samei E. X-ray coherent scatter imaging for surgical margin detection: A Monte Carlo study Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9033. DOI: 10.1117/12.2043856 |
0.327 |
|
2014 |
Mahadevan R, Ikejimba LC, Lin Y, Samei E, Lo JY. A task-based comparison of two reconstruction algorithms for digital breast tomosynthesis Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9033. DOI: 10.1117/12.2043829 |
0.44 |
|
2014 |
Nolte A, Kiarashi N, Samei E, Segars WP, Lo JY. A second generation of physical anthropomorphic 3D breast phantoms based on human subject data Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9033. DOI: 10.1117/12.2043703 |
0.342 |
|
2014 |
Solomon J, Bochud F, Samei E. Design of anthropomorphic Textured phantoms for CT performance evaluation Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9033. DOI: 10.1117/12.2043555 |
0.487 |
|
2014 |
Lakshmanan MN, Kapadia AJ, Sahbaee P, Wolter SD, Harrawood BP, Brady D, Samei E. An X-ray scatter system for material identification in cluttered objects: A Monte Carlo simulation study Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions With Materials and Atoms. 335: 31-38. DOI: 10.1016/J.Nimb.2014.05.021 |
0.32 |
|
2013 |
Norris H, Bond J, Zhang Y, Sturgeon G, Tward D, Ratnanather T, Miller M, Samei E, Segars P. MO-D-141-10: Development of 4D XCAT Pediatric Reference Phantoms for Multi-Modality Imaging Research and Optimization. Medical Physics. 40: 401. PMID 28518471 DOI: 10.1118/1.4815257 |
0.314 |
|
2013 |
Chen B, Barnhart H, Richard S, Robins M, Colsher J, Samei E. Volumetric quantification of lung nodules in CT with iterative reconstruction (ASiR and MBIR). Medical Physics. 40: 111902. PMID 24320435 DOI: 10.1118/1.4823463 |
0.613 |
|
2013 |
Tian X, Li X, Segars WP, Frush DP, Paulson EK, Samei E. Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models. Physics in Medicine and Biology. 58: 8755-68. PMID 24301136 DOI: 10.1088/0031-9155/58/24/8755 |
0.354 |
|
2013 |
Hoang JK, Wang C, Frush DP, Enterline DS, Samei E, Toncheva G, Lowry C, Yoshizumi TT. Estimation of radiation exposure for brain perfusion CT: standard protocol compared with deviations in protocol. Ajr. American Journal of Roentgenology. 201: W730-4. PMID 24063388 DOI: 10.2214/Ajr.12.10031 |
0.346 |
|
2013 |
Boyce SJ, Choudhury KR, Samei E. Effective DQE (eDQE) for monoscopic and stereoscopic chest radiography imaging systems with the incorporation of anatomical noise. Medical Physics. 40: 091916. PMID 24007167 DOI: 10.1118/1.4818060 |
0.418 |
|
2013 |
Swanick CW, Gaca AM, Hollingsworth CL, Maxfield CM, Li X, Samei E, Paulson EK, McCarthy MB, Frush DP. Comparison of conventional and simulated reduced-tube current MDCT for evaluation of suspected appendicitis in the pediatric population. Ajr. American Journal of Roentgenology. 201: 651-8. PMID 23971460 DOI: 10.2214/Ajr.12.9667 |
0.384 |
|
2013 |
Samei E, Murphy S, Christianson O. DQE of wireless digital detectors: comparative performance with differing filtration schemes. Medical Physics. 40: 081910. PMID 23927324 DOI: 10.1118/1.4813298 |
0.392 |
|
2013 |
Marin D, Choudhury KR, Gupta RT, Ho LM, Allen BC, Schindera ST, Colsher JG, Samei E, Nelson RC. Clinical impact of an adaptive statistical iterative reconstruction algorithm for detection of hypervascular liver tumours using a low tube voltage, high tube current MDCT technique. European Radiology. 23: 3325-35. PMID 23832320 DOI: 10.1007/S00330-013-2964-1 |
0.358 |
|
2013 |
Chen B, Marin D, Richard S, Husarik D, Nelson R, Samei E. Precision of iodine quantification in hepatic CT: effects of iterative reconstruction with various imaging parameters. Ajr. American Journal of Roentgenology. 200: W475-82. PMID 23617515 DOI: 10.2214/Ajr.12.9658 |
0.645 |
|
2013 |
Segars WP, Bond J, Frush J, Hon S, Eckersley C, Williams CH, Feng J, Tward DJ, Ratnanather JT, Miller MI, Frush D, Samei E. Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization. Medical Physics. 40: 043701. PMID 23556927 DOI: 10.1118/1.4794178 |
0.397 |
|
2013 |
Wilson JM, Christianson OI, Richard S, Samei E. A methodology for image quality evaluation of advanced CT systems. Medical Physics. 40: 031908. PMID 23464323 DOI: 10.1118/1.4791645 |
0.469 |
|
2013 |
Solomon JB, Li X, Samei E. Relating noise to image quality indicators in CT examinations with tube current modulation. Ajr. American Journal of Roentgenology. 200: 592-600. PMID 23436849 DOI: 10.2214/Ajr.12.8580 |
0.424 |
|
2013 |
Samei E, Murphy S, Richard S. Assessment of multi-directional MTF for breast tomosynthesis Physics in Medicine and Biology. 58: 1649-1661. PMID 23422248 DOI: 10.1088/0031-9155/58/5/1649 |
0.405 |
|
2013 |
Copple C, Robertson ID, Thrall DE, Samei E. Evaluation of two objective methods to optimize kVp and personnel exposure using a digital indirect flat panel detector and simulated veterinary patients. Veterinary Radiology & Ultrasound : the Official Journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association. 54: 9-16. PMID 23293957 DOI: 10.1111/J.1740-8261.2012.01989.X |
0.398 |
|
2013 |
Samei E, Li X, Chen B, Reiman R. The effect of dose heterogeneity on radiation risk in medical imaging. Radiation Protection Dosimetry. 155: 42-58. PMID 23118440 DOI: 10.1093/Rpd/Ncs275 |
0.595 |
|
2013 |
Boyce SJ, McAdams HP, Ravin CE, Patz EF, Washington L, Martinez S, Koweek L, Samei E. Preliminary evaluation of biplane correlation (BCI) stereographic imaging for lung nodule detection Journal of Digital Imaging. 26: 109-114. PMID 22422436 DOI: 10.1007/S10278-012-9466-6 |
0.418 |
|
2013 |
Kiarashi N, Samei E. Digital breast tomosynthesis: A concise overview Imaging in Medicine. 5: 467-476. DOI: 10.2217/Iim.13.52 |
0.421 |
|
2013 |
Christianson O, Winslow J, Solomon J, Samei E. WE-C-103-06: An Automated CT Quality Control Program Medical Physics. 40: 481-481. DOI: 10.1118/1.4815555 |
0.405 |
|
2013 |
Christianson O, Winslow J, Samei E. TU-C-103-10: An Automated Technique to Measure CT Noise in Patient Images Medical Physics. 40: 438-438. DOI: 10.1118/1.4815399 |
0.478 |
|
2013 |
Tian X, Smitherman C, Christiansen O, Frush D, Samei E. TU-C-103-07: Prospective Estimation of Diagnostic Performance and Radiation Dose for Individual CT Scans Medical Physics. 40: 438-438. DOI: 10.1118/1.4815396 |
0.461 |
|
2013 |
Solomon J, Nelson R, Samei E. TU-C-103-01: A Framework for 3D Modeling of Anthropomorphic Lesions in CT Medical Physics. 40: 436-436. DOI: 10.1118/1.4815390 |
0.358 |
|
2013 |
Zhang Y, Li X, Paul Segars W, Samei E. Comparative dosimetry of radiography, tomosynthesis, and CT for chest imaging across 59 adult patients Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8668. DOI: 10.1117/12.2008544 |
0.467 |
|
2013 |
Li X, Segars WP, Samei E. Organ dose in chest CT: Effect of modulation scheme on estimation accuracy Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8668. DOI: 10.1117/12.2008505 |
0.384 |
|
2013 |
Kapadia AJ, Lakshmanan MN, Krishnamurthy K, Sahbaee P, Chawla A, Wolter S, Maccabe K, Brady D, Samei E. Monte-Carlo simulations of a coded-aperture X-ray scatter imaging system for molecular imaging Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8668. DOI: 10.1117/12.2008484 |
0.608 |
|
2013 |
Chen B, Samei E. Development of a phantom-based methodology for the assessment of quantification performance in CT Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8668. DOI: 10.1117/12.2008481 |
0.613 |
|
2013 |
Bond J, Frush D, Samei E, Segars WP. Simulation of anatomical texture in voxelized XCAT phantoms Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8668. DOI: 10.1117/12.2008422 |
0.468 |
|
2013 |
Kiarashi N, Sturgeon GM, Nolte LW, Lo JY, Dobbins JT, Segars WP, Samei E. Development of matched virtual and physical breast phantoms based on patient data Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8668. DOI: 10.1117/12.2008406 |
0.391 |
|
2013 |
Chung H, Ikejimba L, Kiarashi N, Samei E, Hoernig M, Lo JY. Estimating breast density with dual energy mammography: A simple model based on calibration phantoms Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8668. DOI: 10.1117/12.2008398 |
0.311 |
|
2013 |
Solomon J, Samei E. Are uniform phantoms sufficient to characterize the performance of iterative reconstruction in CT? Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8668. DOI: 10.1117/12.2008378 |
0.422 |
|
2013 |
Tian X, Yin Z, De Man B, Samei E. Projection-based dose metric: Accuracy testing and applications for CT design Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8668. DOI: 10.1117/12.2008051 |
0.37 |
|
2012 |
Choudhury KR, Tian R, Li X, Samei E. SU-E-I-47: Comparison of Risks for Two Medical Imaging Procedures. Medical Physics. 39: 3635. PMID 28519515 DOI: 10.1118/1.4734763 |
0.375 |
|
2012 |
Kapadia A, Samei E, Harrawood B, Sahbaee P, Chawla A, Tan Z, Brady D. SU-E-I-77: X-Ray Coherent Scatter Diffraction Pattern Modeling in GEANT4. Medical Physics. 39: 3642-3643. PMID 28517670 DOI: 10.1118/1.4734794 |
0.543 |
|
2012 |
Nelson J, Christianson O, Harkness B, Madsen M, Mah E, Thomas S, Zaidi H, Samei E. SU-D-217A-03: Nuclear Medicine Uniformity Assessment Using 2D Noise Power Spectrum. Medical Physics. 39: 3621. PMID 28517373 DOI: 10.1118/1.4734700 |
0.358 |
|
2012 |
Richard S, Husarik DB, Yadava G, Murphy SN, Samei E. Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithms. Medical Physics. 39: 4115-4122. PMID 28516608 DOI: 10.1118/1.4725171 |
0.309 |
|
2012 |
Christianson O, Li X, Frush D, Samei E. Automated size-specific CT dose monitoring program: assessing variability in CT dose. Medical Physics. 39: 7131-9. PMID 23127104 DOI: 10.1118/1.4761871 |
0.441 |
|
2012 |
Lin Y, Luo H, Dobbins JT, Page McAdams H, Wang X, Sehnert WJ, Barski L, Foos DH, Samei E. An image-based technique to assess the perceptual quality of clinical chest radiographs. Medical Physics. 39: 7019-31. PMID 23127093 DOI: 10.1118/1.4760886 |
0.434 |
|
2012 |
Li X, Samei E, Williams CH, Segars WP, Tward DJ, Miller MI, Ratnanather JT, Paulson EK, Frush DP. Effects of protocol and obesity on dose conversion factors in adult body CT. Medical Physics. 39: 6550-71. PMID 23127050 DOI: 10.1118/1.4754584 |
0.334 |
|
2012 |
Solomon JB, Christianson O, Samei E. Quantitative comparison of noise texture across CT scanners from different manufacturers. Medical Physics. 39: 6048-55. PMID 23039643 DOI: 10.1118/1.4752209 |
0.426 |
|
2012 |
Richard S, Husarik DB, Yadava G, Murphy SN, Samei E. Towards task-based assessment of CT performance: system and object MTF across different reconstruction algorithms. Medical Physics. 39: 4115-22. PMID 22830744 DOI: 10.1118/1.4725171 |
0.423 |
|
2012 |
Zhang Y, Li X, Segars WP, Samei E. Organ doses, effective doses, and risk indices in adult CT: comparison of four types of reference phantoms across different examination protocols. Medical Physics. 39: 3404-23. PMID 22755721 DOI: 10.1118/1.4718710 |
0.38 |
|
2012 |
Husarik DB, Marin D, Samei E, Richard S, Chen B, Jaffe TA, Bashir MR, Nelson RC. Radiation dose reduction in abdominal computed tomography during the late hepatic arterial phase using a model-based iterative reconstruction algorithm: how low can we go? Investigative Radiology. 47: 468-74. PMID 22717881 DOI: 10.1097/Rli.0B013E318251Eafd |
0.658 |
|
2012 |
McCollough CH, Chen GH, Kalender W, Leng S, Samei E, Taguchi K, Wang G, Yu L, Pettigrew RI. Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT. Radiology. 264: 567-80. PMID 22692035 DOI: 10.1148/Radiol.12112265 |
0.461 |
|
2012 |
Schnell EA, Samei E, Dobbins JT. Plate-specific gain map correction for the improvement of detective quantum efficiency in computed radiography. Medical Physics. 39: 1495-504. PMID 22380382 DOI: 10.1118/1.3685580 |
0.317 |
|
2012 |
Samei E, Button TM, Orton CG. Point/Counterpoint: The 2014 initiative can have potentially unintended negative consequences for medical physics in diagnostic imaging and nuclear medicine. Medical Physics. 39: 1167-8; discussion 1. PMID 22380347 DOI: 10.1118/1.3658741 |
0.331 |
|
2012 |
Pollard BJ, Samei E, Chawla AS, Beam C, Heyneman LE, Koweek LMH, Martinez-Jimenez S, Washington L, Hashimoto N, McAdams HP. The effects of ambient lighting in chest radiology reading rooms Journal of Digital Imaging. 25: 520-526. PMID 22349990 DOI: 10.1007/S10278-012-9459-5 |
0.588 |
|
2012 |
Chen B, Barnhart H, Richard S, Colsher J, Amurao M, Samei E. Quantitative CT: technique dependence of volume estimation on pulmonary nodules. Physics in Medicine and Biology. 57: 1335-48. PMID 22349265 DOI: 10.1088/0031-9155/57/5/1335 |
0.565 |
|
2012 |
Samei E, Majdi-Nasab N, Dobbins JT, McAdams HP. Biplane correlation imaging: A feasibility study based on phantom and human data Journal of Digital Imaging. 25: 137-147. PMID 21618054 DOI: 10.1007/S10278-011-9392-Z |
0.418 |
|
2012 |
MacCabe K, Krishnamurthy K, Chawla A, Marks D, Samei E, Brady D. Pencil beam coded aperture x-ray scatter imaging Optics Express. 20: 16310-16320. DOI: 10.1364/Oe.20.016310 |
0.584 |
|
2012 |
Samei E, Christianson O, Chen J, Yang Z, Saiprasad G, Dima A, Filliben J, Peskin A, Siegel E. TH-E-217BCD-09: Task-Based Image Quality of CT Iterative Reconstruction Across Three Commercial Implementations Medical Physics. 39: 4016-4016. DOI: 10.1118/1.4736383 |
0.479 |
|
2012 |
Solomon J, Christianson O, Samei E. TH-E-217BCD-07: Quantitative Comparison of Noise Texture Across CT Scanners from Different Vendors Medical Physics. 39: 4016-4016. DOI: 10.1118/1.4736381 |
0.418 |
|
2012 |
Wilson J, Christianson O, Chen B, Winslow J, Samei E. TH-E-217BCD-04: MA Modulation and Iterative Reconstruction: Evaluation Using a New CT Phantom Medical Physics. 39: 4015-4015. DOI: 10.1118/1.4736378 |
0.417 |
|
2012 |
Li X, Samei E, Solomon J, Frush D. TH-E-217BCD-02: Defining Performance-Based, Size-Specific, Optimized Protocols for Pediatric CT Medical Physics. 39: 4014-4015. DOI: 10.1118/1.4736376 |
0.398 |
|
2012 |
Christianson O, Frush D, Samei E. WE-A-218-08: Comparison of Automated Methods to Measure Patient Size for Dose- Monitoring in Computed Tomography Medical Physics. 39: 3940-3940. DOI: 10.1118/1.4736077 |
0.359 |
|
2012 |
Bower D, Samei E, Johnson J. SU-C-217A-05: The Design of An Institution Wide Comprehensive Technique Chart for Size- Specific Radiography from Pediatrics to Adults Medical Physics. 39: 3608-3608. DOI: 10.1118/1.4734647 |
0.37 |
|
2012 |
Johnson J, Samei E, Christianson O, Bower D. SU-C-217A-02: An Effective Dose Monitoring Program for Computed Radiography Medical Physics. 39: 3607-3607. DOI: 10.1118/1.4734644 |
0.367 |
|
2012 |
Winslow J, Wilson J, Christianson O, Samei E. SU-C-217BCD-03: CT QA Revisited in Context of Tube Current Modulation and Iterative Reconstruction Medical Physics. 39: 3606-3606. DOI: 10.1118/1.4734638 |
0.47 |
|
2012 |
Chen J, Yang Z, Samei E, Christianson O, Dima A, Filliben J, Peskin A, Saiprasad G, Siegel E. SU-C-217BCD-02: Evaluating the Impact of Iterative Reconstruction for Three Major CT Vendors Medical Physics. 39: 3605-3606. DOI: 10.1118/1.4734637 |
0.484 |
|
2012 |
Tian X, Li X, Segars WP, Frush DP, Samei E. Patient- and cohort-specific dose and risk estimation for abdominopelvic CT: a study based on 100 patients Proceedings of Spie. 8313. DOI: 10.1117/12.913341 |
0.362 |
|
2012 |
Kiarashi N, Lin Y, Segars WP, Ghate SV, Ikejimba L, Chen B, Lo JY, Dobbins JT, Nolte LW, Samei E. Development of a dynamic 4D anthropomorphic breast phantom for contrast-based breast imaging Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8313. DOI: 10.1117/12.913332 |
0.578 |
|
2012 |
Chen B, Richard S, Christianson O, Zhou X, Samei E. CT performance as a variable function of resolution, noise, and task property for iterative reconstructions Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8313. DOI: 10.1117/12.913220 |
0.599 |
|
2012 |
Chen B, Richard S, Samei E. Relevance of MTF and NPS in quantitative CT: Towards developing a predictable model of quantitative performance Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8313. DOI: 10.1117/12.913219 |
0.632 |
|
2012 |
Lin Y, Ghate S, Lo J, Samei E. 3D biopsy for tomosynthesis: Simulation of prior information based reconstruction for dose and artifact reduction Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8313. DOI: 10.1117/12.912346 |
0.427 |
|
2012 |
Bond J, Frush J, Hon S, Eckersley C, Williams CH, Feng J, Tward DJ, Ratnanather TJT, Miller MI, Frush D, Samei E, Segars WP. Series of 4D adult XCAT phantoms for imaging research and dosimetry Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8313. DOI: 10.1117/12.911676 |
0.459 |
|
2011 |
Samei E, Anthony Seibert J. The tenuous state of clinical medical physics in diagnostic imaging. Medical Physics. 38: iii-iv. PMID 22149863 DOI: 10.1118/1.3664002 |
0.329 |
|
2011 |
D'Alessandro B, Madsen M, Samei E, Li X, Wooi-Tan J, Berbaum KS, Schartz K, Caldwell R, Zuckier LS. Synthetic positron emission tomography-computed tomography images for use in perceptual studies. Seminars in Nuclear Medicine. 41: 437-48. PMID 21978446 DOI: 10.1053/J.Semnuclmed.2011.06.007 |
0.402 |
|
2011 |
Samei E, Saunders RS. Dual-energy contrast-enhanced breast tomosynthesis: Optimization of beam quality for dose and image quality Physics in Medicine and Biology. 56: 6359-6378. PMID 21908902 DOI: 10.1088/0031-9155/56/19/013 |
0.437 |
|
2011 |
Li X, Samei E, Barnhart HX, Gaca AM, Hollingsworth CL, Maxfield CM, Carrico CW, Colsher JG, Frush DP. Lung nodule detection in pediatric chest CT: quantitative relationship between image quality and radiologist performance. Medical Physics. 38: 2609-18. PMID 21776798 DOI: 10.1118/1.3582975 |
0.467 |
|
2011 |
Samei E, Ranger NT, Dobbins JT, Ravin CE. Effective dose efficiency: an application-specific metric of quality and dose for digital radiography. Physics in Medicine and Biology. 56: 5099-118. PMID 21775791 DOI: 10.1088/0031-9155/56/16/002 |
0.421 |
|
2011 |
Webb LJ, Samei E, Lo JY, Baker JA, Ghate SV, Kim C, Soo MS, Walsh R. Comparative performance of multiview stereoscopic and mammographic display modalities for breast lesion detection. Medical Physics. 38: 1972-80. PMID 21626930 DOI: 10.1118/1.3562901 |
0.44 |
|
2011 |
Kim S, Song H, Samei E, Yin FF, Yoshizumi TT. Computed tomography dose index and dose length product for cone-beam CT: Monte Carlo simulations. Journal of Applied Clinical Medical Physics / American College of Medical Physics. 12: 3395. PMID 21587186 DOI: 10.1120/Jacmp.V12I2.3395 |
0.391 |
|
2011 |
Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Frush DP. Patient-specific radiation dose and cancer risk for pediatric chest CT. Radiology. 259: 862-74. PMID 21467251 DOI: 10.1148/Radiol.11101900 |
0.377 |
|
2011 |
Chen B, Shorey J, Saunders RS, Richard S, Thompson J, Nolte LW, Samei E. An Anthropomorphic Breast Model for Breast Imaging Simulation and Optimization Academic Radiology. 18: 536-546. PMID 21397528 DOI: 10.1016/J.Acra.2010.11.009 |
0.609 |
|
2011 |
Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Toncheva G, Yoshizumi TT, Frush DP. Patient-specific radiation dose and cancer risk estimation in CT: part II. Application to patients. Medical Physics. 38: 408-19. PMID 21361209 DOI: 10.1118/1.3515864 |
0.398 |
|
2011 |
Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Toncheva G, Yoshizumi TT, Frush DP. Patient-specific radiation dose and cancer risk estimation in CT: part I. development and validation of a Monte Carlo program. Medical Physics. 38: 397-407. PMID 21361208 DOI: 10.1118/1.3515839 |
0.401 |
|
2011 |
Wang CL, Chea YW, Boll DT, Samei E, Neville AM, Dale BM, Merkle EM. Effect of gadolinium chelate contrast agents on diffusion weighted MR imaging of the liver, spleen, pancreas and kidney at 3 T. European Journal of Radiology. 80: e1-7. PMID 20646887 DOI: 10.1016/J.Ejrad.2010.05.019 |
0.335 |
|
2011 |
Christianson O, Li X, Frush D, Samei E. TH-A-214-03: Automated Patient-Specific CT Dose Monitoring System: Assessing Variability in CT Dose Medical Physics. 38: 3843-3843. DOI: 10.1118/1.3613468 |
0.406 |
|
2011 |
Zhang Y, Li X, Segars W, Samei E. TH-A-214-02: Organ Dose, Effective Dose, and Dose Conversion Coefficients in Adult CT: Comparison of Mathematical, XCAT, and ICRP Reference Phantoms Medical Physics. 38: 3842-3843. DOI: 10.1118/1.3613467 |
0.378 |
|
2011 |
Sechopoulos I, Abboud S, Ali E, Badal A, Badano A, Feng S, Kyprianou I, McNitt-Gray M, Samei E, Turner A. WE-G-110-06: Introduction to the AAPM Task Group No. 195 - Monte Carlo Reference Data Sets for Imaging Research Medical Physics. 38: 3834-3834. DOI: 10.1118/1.3613436 |
0.336 |
|
2011 |
Murphy S, Richard S, Samei E. WE-G-110-03: Directional MTF Measurement of Tomosynthesis Images Using a Cone-Based Technique Medical Physics. 38: 3833-3833. DOI: 10.1118/1.3613433 |
0.399 |
|
2011 |
Richard S, Samei E. WE-C-110-08: A Novel Phantom for CT Performance Assessment: Towards a Task-Based Measure of Image Quality Medical Physics. 38: 3810-3810. DOI: 10.1118/1.3613347 |
0.486 |
|
2011 |
McNitt-Gray M, Xu X, Samei E. TU-C-110-01: Patient Dose in CT: Calculating Patient Specific Doses in CT(Joint with Education) Medical Physics. 38: 3759-3759. DOI: 10.1118/1.3613145 |
0.387 |
|
2011 |
Richard S, Samei E. SU-D-301-06: Impact of Non-Stationarity in Breast Tomosynthesis on Task-Based Imaging Performance Medical Physics. 38: 3389-3389. DOI: 10.1118/1.3611548 |
0.392 |
|
2011 |
Murphy S, Christianson O, Samei E. SU-C-220-01: Comparative MTF and DQE Performance of Wireless Digital Image Receptors Medical Physics. 38: 3379-3379. DOI: 10.1118/1.3611507 |
0.397 |
|
2011 |
Chen B, Marin D, Samei E. A new iodinated liver phantom for the quantitative evaluation of advanced CT acquisition and reconstruction techniques Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7961. DOI: 10.1117/12.878916 |
0.555 |
|
2011 |
Chen B, Samei E, Colsher J, Barnhart H, Marin D, Nelson R. Precision of Iodine Quantification in Hepatic CT: Effects of Reconstruction (FBP and MBIR) and Imaging Parameters Proceedings of Spie. 7961. DOI: 10.1117/12.878833 |
0.648 |
|
2011 |
Lin Y, Samei E, Luo H, Dobbins JT, McAdams HP, Wang X, Sehnert WJ, Barski L, Foos DH. A patient image-based technique to assess the image quality of clinical chest radiographs Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7961. DOI: 10.1117/12.878765 |
0.434 |
|
2011 |
Li X, Samei E, Segars WP, Paulson EK, Frush DP. The feasibility of universal DLP-to-risk conversion coefficients for body CT protocols Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7961. DOI: 10.1117/12.878616 |
0.344 |
|
2011 |
Richard S, Samei E. 3D task-based performance assessment metrics for optimization of performance and dose in breast tomosynthesis Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7961. DOI: 10.1117/12.877070 |
0.452 |
|
2011 |
Richard S, Li X, Yadava G, Samei E. Predictive models for observer performance in CT: Applications in protocol optimization Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7961. DOI: 10.1117/12.877069 |
0.463 |
|
2010 |
Richard S, Samei E. Quantitative imaging in breast tomosynthesis and CT: Comparison of detection and estimation task performance. Medical Physics. 37: 2627-2637. PMID 28512971 DOI: 10.1118/1.3429025 |
0.305 |
|
2010 |
Richard S, Samei E. Quantitative breast tomosynthesis: from detectability to estimability. Medical Physics. 37: 6157-65. PMID 21302772 DOI: 10.1118/1.3501883 |
0.443 |
|
2010 |
Kim S, Yoo S, Yin FF, Samei E, Yoshizumi T. Kilovoltage cone-beam CT: comparative dose and image quality evaluations in partial and full-angle scan protocols. Medical Physics. 37: 3648-59. PMID 20831072 DOI: 10.1118/1.3438478 |
0.447 |
|
2010 |
Marin D, Nelson RC, Barnhart H, Schindera ST, Ho LM, Jaffe TA, Yoshizumi TT, Youngblood R, Samei E. Detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase: effect of a low-tube-voltage, high-tube-current CT technique--preliminary results. Radiology. 256: 450-9. PMID 20656835 DOI: 10.1148/Radiol.10091819 |
0.383 |
|
2010 |
Richard S, Samei E. Quantitative imaging in breast tomosynthesis and CT: comparison of detection and estimation task performance. Medical Physics. 37: 2627-37. PMID 20632574 DOI: 10.1118/1.3429025 |
0.419 |
|
2010 |
Shafer CM, Samei E, Lo JY. The quantitative potential for breast tomosynthesis imaging. Medical Physics. 37: 1004-16. PMID 20384236 DOI: 10.1118/1.3285038 |
0.439 |
|
2010 |
Ranger NT, Lo JY, Samei E. A technique optimization protocol and the potential for dose reduction in digital mammography. Medical Physics. 37: 962-9. PMID 20384232 DOI: 10.1118/1.3276732 |
0.345 |
|
2010 |
Marin D, Nelson RC, Schindera ST, Richard S, Youngblood RS, Yoshizumi TT, Samei E. Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience. Radiology. 254: 145-53. PMID 20032149 DOI: 10.1148/Radiol.09090094 |
0.416 |
|
2010 |
Flynn M, Samei E, Badano A, Roehrig H. MO-B-201C-01: Color Monitors for Medical Workstations Medical Physics. 37: 3337-3337. DOI: 10.1118/1.3469047 |
0.313 |
|
2010 |
Kim S, Yoo S, Yin F, Samei E, Yoshizumi T. SU-GG-I-57: Dose and Image Quality Evaluation for Partial and Full-Angle Kilovoltage Cone-Beam CT Protocols Medical Physics. 37: 3114-3114. DOI: 10.1118/1.3468090 |
0.422 |
|
2010 |
Kim S, Song H, Samei E, Yin F, Yoshizumi T. SU-GG-I-14: A Method to Estimate Cone-Beam CT Dose Index and Cone-Beam Dose Length Product Medical Physics. 37: 3104-3104. DOI: 10.1118/1.3468047 |
0.36 |
|
2010 |
Lin Y, Wang X, Sehnert WJ, Foos DH, Barski L, Samei E. Quantification of radiographic image quality based on patient anatomical contrast-to-noise ratio: a preliminary study with chest images Proceedings of Spie. 7627. DOI: 10.1117/12.847033 |
0.443 |
|
2010 |
Samei E, Li X, Chen B, Reiman R. The myth of mean dose as a surrogate for radiation risk? Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7622. DOI: 10.1117/12.845940 |
0.586 |
|
2010 |
Thompson J, Chen B, Richard S, Bowsher J, Samei E. Wide-angle breast tomosynthesis: Initial comparative evaluation Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7622. DOI: 10.1117/12.845649 |
0.594 |
|
2010 |
Chen B, Richard S, Barnhart H, Colsher J, Amurao M, Samei E. Quantitative CT: technique dependency of volume assessment for pulmonary nodules Proceedings of Spie. 7622. DOI: 10.1117/12.845493 |
0.579 |
|
2010 |
Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Frush DP. Patient-specific radiation dose and cancer risk estimation in pediatric chest CT: a study in 30 patients Proceedings of Spie. 7622. DOI: 10.1117/12.845491 |
0.387 |
|
2010 |
Richard S, Chen B, Samei E. Extending the detectability index to quantitative imaging performance: Applications in tomosynthesis and CT Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7622. DOI: 10.1117/12.845286 |
0.628 |
|
2010 |
Jacobs J, Marshall N, Cockmartin L, Zanca F, Engen Rv, Young K, Bosmans H, Samei E. Toward an international consensus strategy for periodic quality control of digital breast tomosynthesis systems Proceedings of Spie. 7622: 7622-7622. DOI: 10.1117/12.844228 |
0.424 |
|
2009 |
Chawla AS, Boyce S, Washington L, McAdams HP, Samei E. Design and Development of a New Multi-Projection X-Ray System for Chest Imaging. Ieee Transactions On Nuclear Science. 56: 36-45. PMID 29375155 DOI: 10.1109/Tns.2008.2008647 |
0.646 |
|
2009 |
Samei E, Saunders RS, Badea CT, Ghaghada KB, Hedlund LW, Qi Y, Yuan H, Bentley RC, Mukundan S. Micro-CT imaging of breast tumors in rodents using a liposomal, nanoparticle contrast agent. International Journal of Nanomedicine. 4: 277-282. PMID 20011244 DOI: 10.2147/Ijn.S7881 |
0.396 |
|
2009 |
Chawla AS, Lo JY, Baker JA, Samei E. Optimized image acquisition for breast tomosynthesis in projection and reconstruction space. Medical Physics. 36: 4859-69. PMID 19994493 DOI: 10.1118/1.3231814 |
0.671 |
|
2009 |
Samei E, Ranger NT, MacKenzie A, Honey ID, Dobbins JT, Ravin CE. Effective DQE (eDQE) and speed of digital radiographic systems: an experimental methodology. Medical Physics. 36: 3806-17. PMID 19746814 DOI: 10.1118/1.3171690 |
0.429 |
|
2009 |
Shepard SJ, Wang J, Flynn M, Gingold E, Goldman L, Krugh K, Leong DL, Mah E, Ogden K, Peck D, Samei E, Willis CE. An exposure indicator for digital radiography: AAPM Task Group 116 (Executive Summary) Medical Physics. 36: 2898-2914. PMID 19673189 DOI: 10.1118/1.3121505 |
0.449 |
|
2009 |
Saunders RS, Samei E, Lo JY, Baker JA. Can compression be reduced for breast tomosynthesis? Monte Carlo study on mass and microcalcification conspicuity in tomosynthesis Radiology. 251: 673-682. PMID 19474373 DOI: 10.1148/Radiol.2521081278 |
0.359 |
|
2009 |
Li X, Samei E, DeLong DM, Jones RP, Gaca AM, Hollingsworth CL, Maxfield CM, Colsher JG, Frush DP. Pediatric MDCT: towards assessing the diagnostic influence of dose reduction on the detection of small lung nodules. Academic Radiology. 16: 872-80. PMID 19394875 DOI: 10.1016/J.Acra.2009.01.028 |
0.397 |
|
2009 |
Marin D, Nelson RC, Samei E, Paulson EK, Ho LM, Boll DT, DeLong DM, Yoshizumi TT, Schindera ST. Hypervascular liver tumors: low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection--initial clinical experience. Radiology. 251: 771-9. PMID 19346514 DOI: 10.1148/Radiol.2513081330 |
0.359 |
|
2009 |
Li X, Samei E. Comparison of patient size-based methods for estimating quantum noise in CT images of the lung. Medical Physics. 36: 541-6. PMID 19291993 DOI: 10.1118/1.3058482 |
0.362 |
|
2009 |
Chawla AS, Saunders RS, Singh S, Lo JY, Samei E. Towards Optimized Acquisition Scheme for Multiprojection Correlation Imaging of Breast Cancer Academic Radiology. 16: 456-463. PMID 19268858 DOI: 10.1016/J.Acra.2008.09.013 |
0.646 |
|
2009 |
Pollard BJ, Samei E, Chawla AS, Baker J, Ghate S, Kim C, Soo MS, Hashimoto N. The influence of increased ambient lighting on mass detection in mammograms. Academic Radiology. 16: 299-304. PMID 19201358 DOI: 10.1016/J.Acra.2008.08.017 |
0.604 |
|
2009 |
Li X, Samei E, Delong DM, Jones RP, Gaca AM, Hollingsworth CL, Maxfield CM, Carrico CW, Frush DP. Three-dimensional simulation of lung nodules for paediatric multidetector array CT. The British Journal of Radiology. 82: 401-11. PMID 19153182 DOI: 10.1259/Bjr/51749983 |
0.387 |
|
2009 |
Shafer C, Lo J, Samei E. MO-FF-A4-01: Evaluation of Background Trend Correction Technique in Breast Tomosynthesis Quantitation Medical Physics. 36: 2713-2713. DOI: 10.1118/1.3182295 |
0.424 |
|
2009 |
Richard S, Samei E. SU-FF-I-109: Quantitative Breast Tomosynthesis: Development of An Estimation Performance Metric and Optimization Framework Medical Physics. 36: 2459-2460. DOI: 10.1118/1.3181230 |
0.379 |
|
2009 |
Chawla AS, Samei E, Lo JY. Optimized lesion detection in breast tomosynthesis Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7258. DOI: 10.1117/12.813964 |
0.667 |
|
2009 |
Ranger NT, Mackenzie A, Honey ID, Dobbins JT, Ravin CE, Samei E. Extension of DQE to include scatter, grid, magnification, and focal spot blur: a new experimental technique and metric Proceedings of Spie. 7258. DOI: 10.1117/12.813779 |
0.401 |
|
2009 |
Ertan F, Mackenzie A, Urbanczyk HJ, Ranger NT, Samei E. Use of effective detective quantum efficiency to optimise radiographic exposures for chest imaging with computed radiography Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7258. DOI: 10.1117/12.813650 |
0.422 |
|
2009 |
Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Frush DP. Patient-specific dose estimation for pediatric abdomen-pelvis CT Proceedings of Spie. 7258: 725804. DOI: 10.1117/12.813531 |
0.38 |
|
2009 |
Segars WP, Sturgeon G, Li X, Cheng L, Ceritoglu C, Ratnanather JT, Miller MI, Tsui BMW, Frush D, Samei E. Patient specific computerized phantoms to estimate dose in pediatric CT Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7258. DOI: 10.1117/12.813517 |
0.418 |
|
2009 |
Elojeimy S, Huda W, Ogden KM, Owen R, Samei E, Rumboldt Z. The effect of dose reductions on lesion detection in head CT Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7258. DOI: 10.1117/12.812051 |
0.342 |
|
2009 |
Elojeimy S, Huda W, Ogden KM, Owen R, Samei E, Rumboldt Z. Contrast detail curves in head ct examinations Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7263. DOI: 10.1117/12.811660 |
0.423 |
|
2009 |
Chawla AS, Boyce S, Washington L, McAdams HP, Samei E. Design and development of a new multi-projection X-ray system for chest imaging Ieee Transactions On Nuclear Science. 56: 36-45. DOI: 10.1109/TNS.2008.2008647 |
0.553 |
|
2008 |
Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Frush DP. Patient-specific dose estimation for pediatric chest CT. Medical Physics. 35: 5821-8. PMID 19175138 DOI: 10.1118/1.3026593 |
0.378 |
|
2008 |
Samei E, Ranger NT, MacKenzie A, Honey ID, Dobbins JT, Ravin CE. Detector or system? Extending the concept of detective quantum efficiency to characterize the performance of digital radiographic imaging systems. Radiology. 249: 926-37. PMID 19011189 DOI: 10.1148/Radiol.2492071734 |
0.376 |
|
2008 |
Saunders RS, Samei E. The effect of breast compression on mass conspicuity in digital mammography Medical Physics. 35: 4464-4473. PMID 18975694 DOI: 10.1118/1.2977600 |
0.413 |
|
2008 |
Singh S, Tourassi GD, Baker JA, Samei E, Lo JY. Automated breast mass detection in 3D reconstructed tomosynthesis volumes: a featureless approach. Medical Physics. 35: 3626-36. PMID 18777923 DOI: 10.1118/1.2953562 |
0.308 |
|
2008 |
Williams MB, Raghunathan P, More MJ, Seibert JA, Kwan A, Lo JY, Samei E, Ranger NT, Fajardo LL, McGruder A, McGruder SM, Maidment AD, Yaffe MJ, Bloomquist A, Mawdsley GE. Optimization of exposure parameters in full field digital mammography. Medical Physics. 35: 2414-23. PMID 18649474 DOI: 10.1118/1.2912177 |
0.402 |
|
2008 |
Pollard BJ, Chawla AS, Delong DM, Hashimoto N, Samei E. Object detectability at increased ambient lighting conditions. Medical Physics. 35: 2204-13. PMID 18649449 DOI: 10.1118/1.2907566 |
0.589 |
|
2008 |
Samei E, Ranger NT, Delong DM. A comparative contrast-detail study of five medical displays. Medical Physics. 35: 1358-64. PMID 18491530 DOI: 10.1118/1.2868780 |
0.386 |
|
2008 |
Chawla AS, Samei E, Saunders RS, Lo JY, Baker JA. A mathematical model platform for optimizing a multiprojection breast imaging system Medical Physics. 35: 1337-1345. PMID 18491528 DOI: 10.1118/1.2885367 |
0.663 |
|
2008 |
Schindera ST, Nelson RC, Mukundan S, Paulson EK, Jaffe TA, Miller CM, DeLong DM, Kawaji K, Yoshizumi TT, Samei E. Hypervascular liver tumors: low tube voltage, high tube current multi-detector row CT for enhanced detection--phantom study. Radiology. 246: 125-32. PMID 18096533 DOI: 10.1148/Radiol.2461070307 |
0.411 |
|
2008 |
Fetterly KA, Blume HR, Flynn MJ, Samei E. Introduction to grayscale calibration and related aspects of medical imaging grade liquid crystal displays. Journal of Digital Imaging. 21: 193-207. PMID 17333412 DOI: 10.1007/S10278-007-9022-Y |
0.401 |
|
2008 |
Chawla AS, Samei E, Saunders RS, Lo JY, Singh S. Optimized acquisition scheme for multi-projection correlation imaging of breast cancer Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6915. DOI: 10.1117/12.773174 |
0.561 |
|
2008 |
Singh S, Tourassi GD, Chawla AS, Saunders RS, Samei E, Lo JY. Computer aided detection of breast masses in tomosynthesis reconstructed volumes using information-theoretic similarity measures Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6915. DOI: 10.1117/12.772978 |
0.531 |
|
2008 |
Pollard BJ, Chawla AS, Hashimoto N, Samei E. The effect of increased ambient lighting on detection accuracy in uniform and anatomical backgrounds Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6919. DOI: 10.1117/12.772932 |
0.565 |
|
2008 |
Xiang L, Samei E, DeLong DM, Jones RP, Colsher JG, Frush DP. Towards assessing the diagnostic influence of dose reduction in pediatric CT: A study based on simulated lung nodules Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6913. DOI: 10.1117/12.772089 |
0.303 |
|
2008 |
Chawla AS, Samei E, Lo JY, Mertelmeier T. Multi-projection correlation imaging as a new diagnostic tool for improved breast cancer detection Lecture Notes in Computer Science (Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics). 5116: 635-642. DOI: 10.1007/978-3-540-70538-3_88 |
0.62 |
|
2008 |
Pollard BJ, Chawla AS, Hashimoto N, Samei E. Breast mass detection under increased ambient lighting Lecture Notes in Computer Science (Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics). 5116: 243-248. DOI: 10.1007/978-3-540-70538-3_34 |
0.531 |
|
2007 |
Saunders RS, Baker JA, Delong DM, Johnson JP, Samei E. Does image quality matter? Impact of resolution and noise on mammographic task performance Medical Physics. 34: 3971-3981. PMID 17985642 DOI: 10.1118/1.2776253 |
0.448 |
|
2007 |
Chawla AS, Samei E, Saunders R, Abbey C, Delong D. Effect of dose reduction on the detection of mammographic lesions: a mathematical observer model analysis. Medical Physics. 34: 3385-98. PMID 17879801 DOI: 10.1118/1.2756607 |
0.63 |
|
2007 |
Badea CT, Hedlund LW, De Lin M, Mackel JS, Samei E, Johnson GA. Tomographic digital subtraction angiography for lung perfusion estimation in rodents. Medical Physics. 34: 1546-55. PMID 17555236 DOI: 10.1118/1.2717384 |
0.421 |
|
2007 |
Samei E, Stebbins SA, Dobbins JT, McAdams HP, Lo JY. Multiprojection correlation imaging for improved detection of pulmonary nodules. Ajr. American Journal of Roentgenology. 188: 1239-45. PMID 17449766 DOI: 10.2214/Ajr.06.0843 |
0.402 |
|
2007 |
Samei E, Poolla A, Ulissey MJ, Lewin JM. Digital mammography: comparative performance of color LCD and monochrome CRT displays. Academic Radiology. 14: 539-46. PMID 17434067 DOI: 10.1016/J.Acra.2007.01.022 |
0.408 |
|
2007 |
Ruschin M, Timberg P, Båth M, Hemdal B, Svahn T, Saunders RS, Samei E, Andersson I, Mattsson S, Chakraborty DP, Tingberg A. Dose dependence of mass and microcalcification detection in digital mammography: Free response human observer studies Medical Physics. 34: 400-407. PMID 17388156 DOI: 10.1118/1.2405324 |
0.461 |
|
2007 |
Samei E, Saunders RS, Baker JA, Delong DM. Digital mammography: Effects of reduced radiation dose on diagnostic performance Radiology. 243: 396-404. PMID 17356178 DOI: 10.1148/Radiol.2432061065 |
0.355 |
|
2007 |
Chawla AS, Samei E. Ambient illumination revisited: a new adaptation-based approach for optimizing medical imaging reading environments. Medical Physics. 34: 81-90. PMID 17278493 DOI: 10.1118/1.2402583 |
0.586 |
|
2007 |
Bowsher J, Yin F, Chawla A, Greer K, Song H, Samei E, Willett C. TH-D-M100F-01: An Evaluation of Noise in Radiotracer Emission Imaging Using Flat-Panel Detectors Medical Physics. 34: 2636-2636. DOI: 10.1118/1.2761701 |
0.614 |
|
2007 |
Samei E. TU-E-L100E-01: Image Quality Measurement Workshop Medical Physics. 34: 2570-2571. DOI: 10.1118/1.2761436 |
0.418 |
|
2007 |
Ranger N, Mackenzie A, Honey I, Dobbins J, Ravin C, Samei E. TU-EE-A4-06: Experimental Evaluation of Effective Detective Quantum Efficiency for Digital Radiographic Imaging Systems Medical Physics. 34: 2564-2564. DOI: 10.1118/1.2761409 |
0.391 |
|
2007 |
Williams M, Raghunathan P, Seibert J, Kwan A, Lo J, Samei E, Ranger N, Fajardo L, McGruder A, Maxwell S, Maidment A, Yaffe M, Bloomquist A, Mawdsley G. TU-B-M100J-01: Optimizing Mammography Image Quality and Dose: X-Ray Spectrum and Exposure Parameter Selection Medical Physics. 34: 2540-2541. DOI: 10.1118/1.2761315 |
0.407 |
|
2007 |
Lo J, Singh S, Dobbins J, Samei E. MO-D-L100F-03: New Developments in Digital Breast Tomosynthesis Medical Physics. 34: 2518-2518. DOI: 10.1118/1.2761222 |
0.372 |
|
2007 |
Li X, Samei E, Thomas A, Colsher J, Toth T, Frush D. SU-FF-I-28: Evaluation of a Noise Addition Software for Simulating Low Dose MDCT Images Medical Physics. 34: 2344-2344. DOI: 10.1118/1.2760405 |
0.428 |
|
2007 |
Chawla AS, Samei E, Abbey C. A mathematical model approach towards combining information from multiple image projections of the same patient Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6510. DOI: 10.1117/12.713651 |
0.625 |
|
2007 |
Chawla AS, Pollard B, Samei E, Hashimoto N. Effect of increased ambient lighting on detectability - A psychophysical study Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6516. DOI: 10.1117/12.713559 |
0.519 |
|
2007 |
Chawla AS, Boyce S, Samei E. Design of a new multi-projection imaging system for chest radiography Ieee Nuclear Science Symposium Conference Record. 4: 2996-2999. DOI: 10.1109/NSSMIC.2007.4436764 |
0.611 |
|
2007 |
Chawla AS, Samei E. Geometrical repeatability and motion blur analysis of a new multi-projection X-ray imaging system Ieee Nuclear Science Symposium Conference Record. 5: 3170-3173. DOI: 10.1109/NSSMIC.2006.356548 |
0.539 |
|
2007 |
Bowsher J, Yin F, Greer K, Chawla A, Samei E, Willett C. An Anger-Camera Study of Scatter Effects in Single-photon-Emission Imaging With Flat-Panel Detectors International Journal of Radiation Oncology*Biology*Physics. 69: S727. DOI: 10.1016/J.Ijrobp.2007.07.2124 |
0.597 |
|
2006 |
McKinley RL, Tornai MP, Brzymialkiewicz C, Madhav P, Samei E, Bowsher JE. Analysis of a novel offset cone-beam computed mammotomography system geometry for accomodating various breast sizes. Physica Medica : Pm : An International Journal Devoted to the Applications of Physics to Medicine and Biology : Official Journal of the Italian Association of Biomedical Physics (Aifb). 21: 48-55. PMID 17645994 DOI: 10.1016/S1120-1797(06)80024-4 |
0.403 |
|
2006 |
Siegel E, Krupinski E, Samei E, Flynn M, Andriole K, Erickson B, Thomas J, Badano A, Seibert JA, Pisano ED. Digital mammography image quality: image display. Journal of the American College of Radiology : Jacr. 3: 615-27. PMID 17412136 DOI: 10.1016/J.Jacr.2006.03.007 |
0.415 |
|
2006 |
Saunders RS, Samei E. Improving mammographic decision accuracy by incorporating observer ratings with interpretation time British Journal of Radiology. 79: S117-S122. PMID 17209116 DOI: 10.1259/Bjr/96931332 |
0.307 |
|
2006 |
Lin MD, Samei E, Badea CT, Yoshizumi TT, Johnson GA. Optimized radiographic spectra for small animal digital subtraction angiography. Medical Physics. 33: 4249-57. PMID 17153403 DOI: 10.1118/1.2356646 |
0.425 |
|
2006 |
McAdams HP, Samei E, Dobbins J, Tourassi GD, Ravin CE. Recent advances in chest radiography. Radiology. 241: 663-83. PMID 17114619 DOI: 10.1148/Radiol.2413051535 |
0.427 |
|
2006 |
Samei E, Wright SL. Viewing angle performance of medical liquid crystal displays. Medical Physics. 33: 645-54. PMID 16878568 DOI: 10.1118/1.2168430 |
0.329 |
|
2006 |
Borasi G, Samei E, Bertolini M, Nitrosi A, Tassoni D. Contrast-detail analysis of three flat panel detectors for digital radiography Medical Physics. 33: 1707-1719. PMID 16872078 DOI: 10.1118/1.2191014 |
0.36 |
|
2006 |
Saunders R, Samei E, Baker J, Delong D. Simulation of Mammographic Lesions Academic Radiology. 13: 860-870. PMID 16777560 DOI: 10.1016/J.Acra.2006.03.015 |
0.334 |
|
2006 |
Dobbins JT, Samei E, Ranger NT, Chen Y. Intercomparison of methods for image quality characterization. II. Noise power spectrum Medical Physics. 33: 1466-1475. PMID 16752581 DOI: 10.1118/1.2188819 |
0.344 |
|
2006 |
Samei E, Ranger NT, Dobbins JT, Chen Y. Intercomparison of methods for image quality characterization. I. Modulation transfer function Medical Physics. 33: 1454-1465. PMID 16752580 DOI: 10.1118/1.2188816 |
0.348 |
|
2006 |
Boyce SJ, Samei E. Imaging properties of digital magnification radiography Medical Physics. 33: 984-996. PMID 16696475 DOI: 10.1118/1.2174133 |
0.455 |
|
2006 |
Saunders RS, Samei E. Resolution and noise measurements of five CRT and LCD medical displays Medical Physics. 33: 308-319. PMID 16532935 DOI: 10.1118/1.2150777 |
0.382 |
|
2006 |
Hoe CL, Samei E, Frush DP, Delong DM. Simulation of liver lesions for pediatric CT. Radiology. 238: 699-705. PMID 16371579 DOI: 10.1148/Radiol.2381050477 |
0.353 |
|
2006 |
Fetterly KA, Samei E. A photographic technique for assessing the viewing-angle performance of liquid-crystal displays Journal of the Society For Information Display. 14: 867-872. DOI: 10.1889/1.2372420 |
0.351 |
|
2006 |
Roehrig H, Gaskill J, Fan J, Martin C, Greivenkamp J, Samei E. In-field evaluation of the modulation transfer function and the signal-to-noise ratio of electronic-display devices Journal of the Society For Information Display. 14: 847-860. DOI: 10.1889/1.2372418 |
0.39 |
|
2006 |
Samei E, Cleland E, Roehrig H. In-field assessment of display resolution and noise: Performance evaluation of a commercial measurement system Journal of the Society For Information Display. 14: 839-845. DOI: 10.1889/1.2372417 |
0.358 |
|
2006 |
Saunders R, Samei E. TH-C-330A-02: Does Image Quality Impact Mammographic Accuracy? Medical Physics. 33: 2265-2266. DOI: 10.1118/1.2241844 |
0.437 |
|
2006 |
Bowsher J, Yin F, Greer K, Jaszczak R, Samei E, Willett C. TU-FF-A3-02: Preliminary Investigations Into Combined CT/SPECT Imaging Onboard Therapy Machines Medical Physics. 33: 2221-2221. DOI: 10.1118/1.2241651 |
0.394 |
|
2006 |
Samei E. MO-E-230C-00: Display Evaluation Demonstration Workshop: Part II Medical Physics. 33: 2176-2177. DOI: 10.1118/1.2241477 |
0.357 |
|
2006 |
Samei E. MO-D-230C-01: Evaluation of Medical Displays Medical Physics. 33: 2169-2169. DOI: 10.1118/1.2241446 |
0.337 |
|
2006 |
Chawla AS, Saunders R, Abbey C, Delong D, Samei E. Analyzing the Effect of dose reduction on the detection of mammographic lesions using mathematical observer models Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6146. DOI: 10.1117/12.656378 |
0.567 |
|
2006 |
Chawla AS, Samei E. A method for reduction of eye fatigue by optimizing the ambient light conditions in radiology reading rooms Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6145. DOI: 10.1117/12.655688 |
0.523 |
|
2006 |
Nasab NM, Samei E, Dobbins JT. Biplane correlation imaging for lung nodule detection: Initial human subject results Progress in Biomedical Optics and Imaging - Proceedings of Spie. 6144. DOI: 10.1117/12.652582 |
0.314 |
|
2006 |
Samei E. Why Medical Image Perception? Journal of the American College of Radiology. 3: 400-401. DOI: 10.1016/J.Jacr.2006.02.017 |
0.343 |
|
2006 |
Bowsher J, Yin F, Chawla A, Greer K, Jaszczak R, Samei E, Willett C. 1032 International Journal of Radiation Oncology*Biology*Physics. 66: S147-S148. DOI: 10.1016/J.Ijrobp.2006.07.297 |
0.553 |
|
2005 |
Samei E, Buhr E, Granfors P, Vandenbroucke D, Wang X. Comparison of edge analysis techniques for the determination of the MTF of digital radiographic systems Physics in Medicine and Biology. 50: 3613-3625. PMID 16030386 DOI: 10.1088/0031-9155/50/15/009 |
0.384 |
|
2005 |
Samei E, Dobbins JT, Lo JY, Tornai MP. A framework for optimising the radiographic technique in digital X-ray imaging. Radiation Protection Dosimetry. 114: 220-9. PMID 15933112 DOI: 10.1093/Rpd/Nch562 |
0.467 |
|
2005 |
Samei E, Badano A, Chakraborty D, Compton K, Cornelius C, Corrigan K, Flynn MJ, Hemminger B, Hangiandreou N, Johnson J, Moxley-Stevens DM, Pavlicek W, Roehrig H, Rutz L, Shepard J, et al. Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report. Medical Physics. 32: 1205-25. PMID 15895604 DOI: 10.1118/1.1861159 |
0.359 |
|
2005 |
Samei E, Lo JY, Yoshizumi TT, Jesneck JL, Dobbins JT, Floyd CE, McAdams HP, Ravin CE. Comparative scatter and dose performance of slot-scan and full-field digital chest radiography systems. Radiology. 235: 940-9. PMID 15845791 DOI: 10.1148/Radiol.2353040516 |
0.35 |
|
2005 |
Samei E. Technological and psychophysical considerations for digital mammographic displays Radiographics. 25: 491-501. PMID 15798066 DOI: 10.1148/Rg.252045185 |
0.334 |
|
2005 |
Saunders RS, Samei E, Jesneck JL, Lo JY. Physical characterization of a prototype selenium-based full field digital mammography detector Medical Physics. 32: 588-599. PMID 15789606 DOI: 10.1118/1.1855033 |
0.371 |
|
2005 |
Jung H, Kim HJ, Kang WS, Yoo SK, Fujioka K, Hasegawa M, Samei E. Assessment of flat panel LCD primary class display performance based on AAPM TG 18 acceptance protocol. Medical Physics. 31: 2155-64. PMID 15305470 DOI: 10.1118/1.1764946 |
0.364 |
|
2005 |
Krupinski E, Samei E, Eckstein M. WE-E-I-609-01: Advances In Perception & Visualization Medical Physics. 32: 2142-2142. DOI: 10.1118/1.1999741 |
0.397 |
|
2005 |
Samei E. MO-E-W-608-01: Display Evaluation Demonstration Workshop Medical Physics. 32: 2073-2073. DOI: 10.1118/1.1998315 |
0.342 |
|
2005 |
Tornai MP, McKinley RL, Brzymialkiewicz CN, Madhav P, Cutler SJ, Crotty DJ, Bowsher JE, Samei E, Floyd CE. Design and development of a fully-3D dedicated x-ray computed mammotomography system Progress in Biomedical Optics and Imaging - Proceedings of Spie. 5745: 189-197. DOI: 10.1117/12.595636 |
0.315 |
|
2005 |
Boyce SJ, Chawla A, Samei E. Physical evaluation of a high frame rate, extended dynamic range flat panel detector for real-time cone beam computed tomography applications Progress in Biomedical Optics and Imaging - Proceedings of Spie. 5745: 591-599. DOI: 10.1117/12.593881 |
0.58 |
|
2005 |
Poolla A, Sun Y, Samei E, Suri J. Studying the effect of physics-based-enhancement on LCDs (IBM's 9.2 MP) and CRTs (Barco's 5 MP) on X=ray Mammograms acquired using Full Field Digital Mammography and Ultrasound (FFDMUS) System Sid Conference Record of the International Display Research Conference. 162-165. |
0.302 |
|
2004 |
Samei E, Rowberg A, Avraham E, Cornelius C. Toward clinically relevant standardization of image quality Journal of Digital Imaging. 17: 271-278. PMID 15551103 DOI: 10.1007/S10278-004-1031-5 |
0.4 |
|
2004 |
Samei E, Saunders RS, Lo JY, Dobbins JT, Jesneck JL, Floyd CE, Ravin CE. Fundamental imaging characteristics of a slot-scan digital chest radiographic system Medical Physics. 31: 2687-2698. PMID 15487752 DOI: 10.1118/1.1783531 |
0.461 |
|
2004 |
Neitzel U, Günther-Kohfahl S, Borasi G, Samei E. Determination of the detective quantum efficiency of a digital x-ray detector: Comparison of three evaluations using a common image data set Medical Physics. 31: 2205-2211. PMID 15377085 DOI: 10.1118/1.1766421 |
0.374 |
|
2004 |
Saunders RS, Samei E, Hoeschen C. Impact of resolution and noise characteristics of digital radiographic detectors on the detectability of lung nodules Medical Physics. 31: 1603-1613. PMID 15259665 DOI: 10.1118/1.1753112 |
0.431 |
|
2004 |
McKinley RL, Tornai MP, Samei E, Bradshaw ML. Simulation study of a quasi-monochromatic beam for x-ray computed mammotomography. Medical Physics. 31: 800-13. PMID 15124997 DOI: 10.1118/1.1668371 |
0.376 |
|
2003 |
Saunders RS, Samei E. A method for modifying the image quality parameters of digital radiographic images. Medical Physics. 30: 3006-17. PMID 14655948 DOI: 10.1118/1.1621870 |
0.395 |
|
2003 |
Samei E. Image quality in two phosphor-based flat panel digital radiographic detectors Medical Physics. 30: 1747-1757. PMID 12906192 DOI: 10.1118/1.1578772 |
0.349 |
|
2003 |
Samei E, Flynn MJ. An experimental comparison of detector performance for direct and indirect digital radiography systems. Medical Physics. 30: 608-22. PMID 12722813 DOI: 10.1118/1.1561285 |
0.323 |
|
2003 |
Samei E, Hill JG, Frey GD, Southgate WM, Mah E, Delong D. Evaluation of a flat panel digital radiographic system for low-dose portable imaging of neonates. Medical Physics. 30: 601-7. PMID 12722812 DOI: 10.1118/1.1556611 |
0.472 |
|
2003 |
Samei E, Catarious DM, Baydush AH, Floyd CE, Vargas-Voracek R. Bi-plane correlation imaging for improved detection of lung nodules Proceedings of Spie - the International Society For Optical Engineering. 5030: 284-297. DOI: 10.1117/12.480478 |
0.351 |
|
2002 |
Samei E, Flynn MJ. An experimental comparison of detector performance for computed radiography systems. Medical Physics. 29: 447-59. PMID 11991117 DOI: 10.1118/1.1449873 |
0.359 |
|
2001 |
Samei E, Seibert JA, Willis CE, Flynn MJ, Mah E, Junck KL. Performance evaluation of computed radiography systems. Medical Physics. 28: 361-71. PMID 11318318 DOI: 10.1118/1.1350586 |
0.306 |
|
2001 |
Samei E. Objective performance evaluation of medical image displays: A preliminary report of the AAPM TG18 Proceedings of Spie - the International Society For Optical Engineering. 4295: 159-163. DOI: 10.1117/12.424870 |
0.404 |
|
2000 |
Kearfott KJ, Han S, Wagner EC, Samei E, Wang CK. Numerical simulation of a TLD pulsed laser-heating scheme for determination of shallow dose and deep dose in low-LET radiation fields. Applied Radiation and Isotopes : Including Data, Instrumentation and Methods For Use in Agriculture, Industry and Medicine. 52: 1419-29. PMID 10855671 DOI: 10.1016/S0969-8043(99)00251-1 |
0.302 |
|
1999 |
Samei E, Flynn MJ, Eyler WR. Detection of subtle lung nodules: Relative influence of quantum and anatomic noise on chest radiographs Radiology. 213: 727-734. PMID 10580946 DOI: 10.1148/Radiology.213.3.R99Dc19727 |
0.384 |
|
1998 |
Beute GH, Flynn MJ, Eyler WR, Samei E, Spizarny DL, Zylak CJ. Chest radiographic image quality: comparison of asymmetric screen-film, digital storage phosphor, and digital selenium drum systems--preliminary study. Radiographics : a Review Publication of the Radiological Society of North America, Inc. 18: 745-54. PMID 9599395 DOI: 10.1148/Radiographics.18.3.9599395 |
0.369 |
|
1998 |
Samei E, Flynn MJ, Reimann DA. A method for measuring the presampled MTF of digital radiographic systems using an edge test device Medical Physics. 25: 102-113. PMID 9472832 DOI: 10.1118/1.598165 |
0.351 |
|
1998 |
Samei E. The performance of digital x-ray imaging systems in detection of subtle lung nodules Medical Physics. 25: 2077-2077. DOI: 10.1118/1.598364 |
0.368 |
|
1997 |
Samei E, Flynn MJ, Eyler WR. Simulation of subtle lung nodules in projection chest radiography Radiology. 202: 117-124. PMID 8988200 DOI: 10.1148/Radiology.202.1.8988200 |
0.369 |
|
1995 |
Samei E, Kearfott KJ, Wang CKC. Numerical modelling of a new method for determination of shallow dose and deep dose in low let radiation fields Radiation Protection Dosimetry. 58: 103-113. DOI: 10.1093/Oxfordjournals.Rpd.A082604 |
0.335 |
|
Show low-probability matches. |