Year |
Citation |
Score |
2011 |
Anderson CC, Bauer AQ, Marutyan KR, Holland MR, Pakula M, Bretthorst GL, Laugier P, Miller JG. Phase velocity of cancellous bone: Negative dispersion arising from fast and slow waves, interference, diffraction, and phase cancellation at piezoelectric receiving elements Bone Quantitative Ultrasound. 319-330. DOI: 10.1007/978-94-007-0017-8_12 |
0.765 |
|
2009 |
Anderson CC, Pakula M, Laugier P, Bauer AQ, Marutyan K, Bretthorst GL, Holland MR, Miller JG. Successful use of Bayesian inference to obtain the fast and slow wave properties of cancellous bone from sonometry measurements. The Journal of the Acoustical Society of America. 125: 2641-2641. DOI: 10.1121/1.4784101 |
0.758 |
|
2009 |
Miller JG, Anderson CC, Bauer AQ, Marutyan K, Bretthorst GL, Holland MR, Hoffmeister BK, Wear KA. Cancellous bone as a poroelastic medium: Extracting underlying material properties from improved ultrasonic measurements of frequency dependent attenuation and phase velocity. The Journal of the Acoustical Society of America. 125: 2641-2641. DOI: 10.1121/1.4784100 |
0.783 |
|
2008 |
Anderson CC, Marutyan KR, Holland MR, Wear KA, Miller JG. Interference between wave modes may contribute to the apparent negative dispersion observed in cancellous bone. The Journal of the Acoustical Society of America. 124: 1781-9. PMID 19045668 DOI: 10.1121/1.2953309 |
0.729 |
|
2008 |
Bauer AQ, Marutyan KR, Holland MR, Miller JG. Negative dispersion in bone: the role of interference in measurements of the apparent phase velocity of two temporally overlapping signals. The Journal of the Acoustical Society of America. 123: 2407-14. PMID 18397043 DOI: 10.1121/1.2839893 |
0.773 |
|
2008 |
Bauer AQ, Anderson CC, Marutyan KR, Bretthorst GL, Wear KA, Holland MR, Miller JG. Experimental confirmation of negative dispersion and Bayesian inversion of multimode propagation in a bone‐mimicking phantom The Journal of the Acoustical Society of America. 123: 3512-3512. DOI: 10.1121/1.2934415 |
0.772 |
|
2007 |
Baldwin SL, Yang M, Marutyan KR, Wallace KD, Holland MR, Miller JG. Ultrasonic detection of the anisotropy of protein cross linking in myocardium at diagnostic frequencies. Ieee Transactions On Ultrasonics, Ferroelectrics, and Frequency Control. 54: 1360-9. PMID 17718325 DOI: 10.1109/Tuffc.2007.396 |
0.665 |
|
2007 |
Bauer AQ, Marutyan KR, Holland MR, Miller JG. Is the Kramers-Kronig relationship between ultrasonic attenuation and dispersion maintained in the presence of apparent losses due to phase cancellation? The Journal of the Acoustical Society of America. 122: 222-8. PMID 17614481 DOI: 10.1121/1.2735803 |
0.732 |
|
2007 |
Marutyan KR, Bretthorst GL, Miller JG. Bayesian estimation of the underlying bone properties from mixed fast and slow mode ultrasonic signals. The Journal of the Acoustical Society of America. 121: EL8-15. PMID 17297820 DOI: 10.1121/1.2401198 |
0.602 |
|
2007 |
Bauer AQ, Marutyan KR, Holland MR, Miller JG. Is the Kramers‐Kronig causal relationship between ultrasonic attenuation and dispersion maintained when phase aberrations distort the field incident on a phase sensitive aperture? The Journal of the Acoustical Society of America. 121: 3084-3084. DOI: 10.1121/1.4781932 |
0.736 |
|
2007 |
Anderson CC, Marutyan KR, Wear KA, Holland MR, Miller JG, Bretthorst GL. Model selection in ultrasonic measurements on trabecular bone Aip Conference Proceedings. 954: 337-345. DOI: 10.1063/1.2821280 |
0.666 |
|
2007 |
Marutyan KR, Anderson CC, Wear KA, Holland MR, Miller JG, Bretthorst GL. Parameter estimation in ultrasonic measurements on trabecular bone Aip Conference Proceedings. 954: 329-336. DOI: 10.1063/1.2821279 |
0.663 |
|
2006 |
Marutyan KR, Holland MR, Miller JG. Anomalous negative dispersion in bone can result from the interference of fast and slow waves. The Journal of the Acoustical Society of America. 120: EL55-61. PMID 17139755 DOI: 10.1121/1.2357187 |
0.677 |
|
2006 |
Baldwin SL, Marutyan KR, Yang M, Wallace KD, Holland MR, Miller JG. Measurements of the anisotropy of ultrasonic attenuation in freshly excised myocardium. The Journal of the Acoustical Society of America. 119: 3130-9. PMID 16708967 DOI: 10.1121/1.2188333 |
0.696 |
|
2006 |
Marutyan KR, Yang M, Baldwin SL, Wallace KD, Holland MR, Miller JG. The frequency dependence of ultrasonic velocity and the anisotropy of dispersion in both freshly excised and formalin-fixed myocardium. Ultrasound in Medicine & Biology. 32: 603-10. PMID 16616606 DOI: 10.1016/J.Ultrasmedbio.2005.12.002 |
0.74 |
|
2006 |
Yang M, Baldwin SL, Marutyan KR, Wallace KD, Holland MR, Miller JG. Elastic stiffness coefficients (c11, C33, and C13) for freshly excised and formalin-fixed myocardium from ultrasonic velocity measurements. The Journal of the Acoustical Society of America. 119: 1880-7. PMID 16583926 DOI: 10.1121/1.2168547 |
0.691 |
|
2006 |
Miller JG, Marutyan K, Holland MR. Toward bone quality assessment: Interference of fast and slow wave modes with positive dispersion can account for the apparent negative dispersion The Journal of the Acoustical Society of America. 120: 3244-3244. DOI: 10.1121/1.4788279 |
0.66 |
|
2006 |
Marutyan KR, Holland MR, Miller JG. Evidence that the negative dispersion in bone results from interference between fast and slow modes each with positive dispersion Proceedings - Ieee Ultrasonics Symposium. 1: 17-20. DOI: 10.1109/ULTSYM.2006.19 |
0.331 |
|
2005 |
Baldwin SL, Yang M, Marutyan KR, Wallace KD, Holland MR, Miller JG. Measurements of the anisotropy of ultrasonic velocity in freshly excised and formalin-fixed myocardial tissue. The Journal of the Acoustical Society of America. 118: 505-13. PMID 16119369 DOI: 10.1121/1.1925947 |
0.693 |
|
2005 |
Baldwin SL, Marutyan KR, Yang M, Wallace KD, Holland MR, Miller JG. Estimating myocardial attenuation from M-mode ultrasonic backscatter. Ultrasound in Medicine & Biology. 31: 477-84. PMID 15831326 DOI: 10.1016/J.Ultrasmedbio.2004.12.024 |
0.7 |
|
2004 |
Baldwin SL, Yang M, Marutyan KR, Wallace KD, Holland MR, Miller JG. Influence of bright intramural echoes on estimates of ultrasonic attenuation from backscattered ultrasound in excised myocardium. Ultrasonic Imaging. 26: 233-49. PMID 15864981 DOI: 10.1177/016173460402600403 |
0.688 |
|
Show low-probability matches. |