Jason P. Stockmann, Ph.D. - Publications

Affiliations: 
Yale University, New Haven, CT 
Area:
Neuroscience, brain imaging, MR physics

42 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2023 Feinberg DA, Beckett AJS, Vu AT, Stockmann J, Huber L, Ma S, Ahn S, Setsompop K, Cao X, Park S, Liu C, Wald LL, Polimeni JR, Mareyam A, Gruber B, et al. Next-generation MRI scanner designed for ultra-high-resolution human brain imaging at 7 Tesla. Nature Methods. PMID 38012321 DOI: 10.1038/s41592-023-02068-7  0.409
2023 Gruber B, Stockmann JP, Mareyam A, Keil B, Bilgic B, Chang Y, Kazemivalipour E, Beckett AJS, Vu AT, Feinberg DA, Wald LL. A 128-channel receive array for cortical brain imaging at 7 T. Magnetic Resonance in Medicine. PMID 37582214 DOI: 10.1002/mrm.29798  0.329
2023 Navarro de Lara LI, Stockmann JP, Meng Q, Keil B, Mareyam A, Uluç I, Daneshzand M, Makarov S, Wald LL, Nummenmaa A. A novel whole-head RF coil design tailored for concurrent multichannel brain stimulation and imaging at 3T. Brain Stimulation. 16: 1021-1031. PMID 37307872 DOI: 10.1016/j.brs.2023.05.025  0.302
2023 Negnevitsky V, Vives-Gilabert Y, Algarín JM, Craven-Brightman L, Pellicer-Guridi R, O'Reilly T, Stockmann JP, Webb A, Alonso J, Menküc B. MaRCoS, an open-source electronic control system for low-field MRI. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 350: 107424. PMID 37001194 DOI: 10.1016/j.jmr.2023.107424  0.354
2022 Pinho Meneses B, Stockmann JP, Arango N, Gapais PF, Giacomini E, Mauconduit F, Gras V, Boulant N, Vignaud A, Luong M, Amadon A. Shim coils tailored for correcting B0 inhomogeneity in the human brain (SCOTCH): Design methodology and 48-channel prototype assessment in 7-Tesla MRI. Neuroimage. 261: 119498. PMID 35917918 DOI: 10.1016/j.neuroimage.2022.119498  0.344
2022 Sveinsson B, Rowe OE, Stockmann JP, Park DJ, Lally PJ, Rosen MS, Barry RL, Eichler F, Rosen BR, Sadjadi R. Feasibility of simultaneous high-resolution anatomical and quantitative MR imaging of sciatic nerves in patients with Charcot-Marie-Tooth Type 1A (CMT1A) at 7T. Muscle & Nerve. PMID 35621349 DOI: 10.1002/mus.27647  0.634
2021 Thapa B, Mareyam A, Stockmann J, Strasser B, Keil B, Hoecht P, Carp S, Li X, Wang Z, Chang YV, Dietrich J, Uhlmann E, Cahill DP, Batchelor T, Wald L, et al. In Vivo Absolute Metabolite Quantification Using a Multiplexed ERETIC-RX Array Coil for Whole-Brain MR Spectroscopic Imaging. Journal of Magnetic Resonance Imaging : Jmri. PMID 34958166 DOI: 10.1002/jmri.28028  0.323
2021 Strasser B, Arango NS, Stockmann JP, Gagoski B, Thapa B, Li X, Bogner W, Moser P, Small J, Cahill DP, Batchelor TT, Dietrich J, van der Kouwe A, White J, Adalsteinsson E, et al. Improving D-2-hydroxyglutarate MR spectroscopic imaging in mutant isocitrate dehydrogenase glioma patients with multiplexed RF-receive/B -shim array coils at 3 T. Nmr in Biomedicine. e4621. PMID 34609036 DOI: 10.1002/nbm.4621  0.323
2021 Srinivas SA, Cauley SF, Stockmann JP, Sappo CR, Vaughn CE, Wald LL, Grissom WA, Cooley CZ. External Dynamic InTerference Estimation and Removal (EDITER) for low field MRI. Magnetic Resonance in Medicine. PMID 34480778 DOI: 10.1002/mrm.28992  0.787
2021 Scholz A, Etzel R, May M, Mahmutovic M, Tian Q, Ramos-Llordén G, Maffei C, Bilgiç B, Witzel T, Stockmann JP, Mekkaoui C, L Wald L, Huang SY, Yendiki A, Keil B. A 48-Channel Receive Array Coil for Mesoscopic Diffusion-Weighted MRI of ex vivo Human Brain on the 3 T Connectome Scanner. Neuroimage. 118256. PMID 34118399 DOI: 10.1016/j.neuroimage.2021.118256  0.343
2021 Mateen FJ, Cooley CZ, Stockmann JP, Rice DR, Vogel AC, Wald LL. Low-field portable brain MRI in CNS demyelinating disease. Multiple Sclerosis and Related Disorders. 51: 102903. PMID 33780808 DOI: 10.1016/j.msard.2021.102903  0.779
2021 Manhard MK, Stockmann J, Liao C, Park D, Han S, Fair M, van den Boomen M, Polimeni J, Bilgic B, Setsompop K. A multi-inversion multi-echo spin and gradient echo echo planar imaging sequence with low image distortion for rapid quantitative parameter mapping and synthetic image contrasts. Magnetic Resonance in Medicine. PMID 33764563 DOI: 10.1002/mrm.28761  0.391
2020 Cooley CZ, McDaniel PC, Stockmann JP, Srinivas SA, Cauley SF, Śliwiak M, Sappo CR, Vaughn CF, Guerin B, Rosen MS, Lev MH, Wald LL. A portable scanner for magnetic resonance imaging of the brain. Nature Biomedical Engineering. PMID 33230306 DOI: 10.1038/s41551-020-00641-5  0.816
2020 Esmaeili M, Stockmann J, Strasser B, Arango N, Thapa B, Wang Z, van der Kouwe A, Dietrich J, Cahill DP, Batchelor TT, White J, Adalsteinsson E, Wald L, Andronesi OC. An integrated RF-receive/B-shim array coil boosts performance of whole-brain MR spectroscopic imaging at 7 T. Scientific Reports. 10: 15029. PMID 32929121 DOI: 10.1038/S41598-020-71623-5  0.45
2020 Cooley CZ, Stockmann JP, Witzel T, LaPierre C, Mareyam A, Jia F, Zaitsev M, Yang W, Zheng W, Stang P, Scott G, Adalsteinsson E, White JK, Wald LL. Corrigendum to "Design and implementation of a low-cost, tabletop MRI scanner for education and research prototyping" [J. Magn. Reson. 310 (2020) 106625]. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 317: 106764. PMID 32589583 DOI: 10.1016/J.Jmr.2020.106764  0.759
2020 Navarro de Lara LI, Golestanirad L, Makarov SN, Stockmann JP, Wald LL, Nummenmaa A. Evaluation of RF interactions between a 3T birdcage transmit coil and transcranial magnetic stimulation coils using a realistically shaped head phantom. Magnetic Resonance in Medicine. PMID 31971632 DOI: 10.1002/Mrm.28162  0.395
2020 Nasr S, LaPierre C, Vaughn CE, Witzel T, Stockmann JP, Polimeni JR. In vivo functional localization of the temporal monocular crescent representation in human primary visual cortex. Neuroimage. 116516. PMID 31904490 DOI: 10.1016/J.Neuroimage.2020.116516  0.75
2019 Gao Y, Mareyam A, Sun Y, Witzel T, Arango N, Kuang I, White J, Roe AW, Wald L, Stockmann J, Zhang X. A 16-channel AC/DC array coil for anesthetized monkey whole-brain imaging at 7T. Neuroimage. 116396. PMID 31778818 DOI: 10.1016/J.Neuroimage.2019.116396  0.513
2019 Cooley CZ, Stockmann JP, Witzel T, LaPierre C, Mareyam A, Jia F, Zaitsev M, Wenhui Y, Zheng W, Stang P, Scott G, Adalsteinsson E, White JK, Wald LL. Design and implementation of a low-cost, tabletop MRI scanner for education and research prototyping. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 310: 106625. PMID 31765969 DOI: 10.1016/J.Jmr.2019.106625  0.77
2019 Edlow BL, Mareyam A, Horn A, Polimeni JR, Witzel T, Tisdall MD, Augustinack JC, Stockmann JP, Diamond BR, Stevens A, Tirrell LS, Folkerth RD, Wald LL, Fischl B, van der Kouwe A. 7 Tesla MRI of the ex vivo human brain at 100 micron resolution. Scientific Data. 6: 244. PMID 31666530 DOI: 10.1038/S41597-019-0254-8  0.404
2019 Zhou J, Stockmann JP, Arango N, Witzel T, Scheffler K, Wald LL, Lin FH. The orthogonal shim coil for 3T brain imaging. Magnetic Resonance in Medicine. PMID 31631391 DOI: 10.1002/Mrm.28010  0.482
2019 Wald LL, McDaniel PC, Witzel T, Stockmann JP, Cooley CZ. Low-cost and portable MRI. Journal of Magnetic Resonance Imaging : Jmri. PMID 31605435 DOI: 10.1002/Jmri.26942  0.789
2019 Liao C, Stockmann J, Tian Q, Bilgic B, Arango NS, Manhard MK, Huang SY, Grissom WA, Wald LL, Setsompop K. High-fidelity, high-isotropic-resolution diffusion imaging through gSlider acquisition with and T corrections and integrated ΔB /Rx shim array. Magnetic Resonance in Medicine. PMID 31373048 DOI: 10.1002/Mrm.27899  0.41
2019 McDaniel PC, Cooley CZ, Stockmann JP, Wald LL. The MR Cap: A single-sided MRI system designed for potential point-of-care limited field-of-view brain imaging. Magnetic Resonance in Medicine. PMID 31231885 DOI: 10.1002/Mrm.27861  0.805
2018 Navarro de Lara LI, Rad LG, Makarov SN, Stockmann J, Wald LL, Nummenmaa A. Simulations of a birdcage coil B+ field on a human body model for designing a 3T multichannel TMS/MRI head coil array. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2018: 4752-4755. PMID 30441411 DOI: 10.1109/EMBC.2018.8513208  0.345
2018 Cooley CZ, Haskell MW, Cauley SF, Sappo C, Lapierre CD, Ha CG, Stockmann JP, Wald LL. Design of sparse Halbach magnet arrays for portable MRI using a genetic algorithm. Ieee Transactions On Magnetics. 54. PMID 29749974 DOI: 10.1109/Tmag.2017.2751001  0.767
2017 Stockmann JP, Wald LL. In Vivo B0 Field Shimming Methods for MRI at 7 T. Neuroimage. PMID 28602943 DOI: 10.1016/J.Neuroimage.2017.06.013  0.471
2017 Setsompop K, Fan Q, Stockmann J, Bilgic B, Huang S, Cauley SF, Nummenmaa A, Wang F, Rathi Y, Witzel T, Wald LL. High-resolution in vivo diffusion imaging of the human brain with generalized slice dithered enhanced resolution: Simultaneous multislice (gSlider-SMS). Magnetic Resonance in Medicine. PMID 28261904 DOI: 10.1002/Mrm.26653  0.42
2016 Jiazheng Zhou, Ying-Hua Chu, Yi-Cheng Hsu, Pu-Yeh Wu, Stockmann JP, Fa-Hsuan Lin. Integrated RF-shim coil allowing two degrees of freedom shim current. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2016: 6246-6249. PMID 28269679 DOI: 10.1109/EMBC.2016.7592156  0.349
2016 Zhou J, Chu YH, Hsu YC, Wu PY, Stockmann JP, Lin FH, Jiazheng Zhou, Ying-Hua Chu, Yi-Cheng Hsu, Pu-Yeh Wu, Stockmann JP, Fa-Hsuan Lin, Wu PY, Stockmann JP, Lin FH, et al. Integrated RF-shim coil allowing two degrees of freedom shim current. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2016: 6246-6249. PMID 28227938 DOI: 10.1109/EMBC.2016.7592156  0.349
2016 Stockmann JP, Cooley CZ, Guerin B, Rosen MS, Wald LL. Transmit Array Spatial Encoding (TRASE) using broadband WURST pulses for RF spatial encoding in inhomogeneous B0 fields. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 268: 36-48. PMID 27155906 DOI: 10.1016/J.Jmr.2016.04.005  0.795
2015 Stockmann JP, Witzel T, Keil B, Polimeni JR, Mareyam A, LaPierre C, Setsompop K, Wald LL. A 32-channel combined RF and B0 shim array for 3T brain imaging. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. PMID 25689977 DOI: 10.1002/Mrm.25587  0.776
2015 Tam LK, Galiana G, Stockmann JP, Tagare H, Peters DC, Constable RT. Pseudo-random center placement O-space imaging for improved incoherence compressed sensing parallel MRI. Magnetic Resonance in Medicine. 73: 2212-24. PMID 25042143 DOI: 10.1002/Mrm.25364  0.81
2015 Li S, Chan C, Stockmann JP, Tagare H, Adluru G, Tam LK, Galiana G, Constable RT, Kozerke S, Peters DC. Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: application to cardiac cine. Magnetic Resonance in Medicine. 73: 1643-53. PMID 24753213 DOI: 10.1002/Mrm.25265  0.775
2015 Cooley CZ, Stockmann JP, Armstrong BD, Sarracanie M, Lev MH, Rosen MS, Wald LL. Two-dimensional imaging in a lightweight portable MRI scanner without gradient coils. Magnetic Resonance in Medicine. 73: 872-83. PMID 24668520 DOI: 10.1002/Mrm.25147  0.77
2014 Sarracanie M, Armstrong BD, Stockmann J, Rosen MS. High speed 3D overhauser-enhanced MRI using combined b-SSFP and compressed sensing. Magnetic Resonance in Medicine. 71: 735-45. PMID 23475813 DOI: 10.1002/Mrm.24705  0.781
2013 Stockmann JP, Galiana G, Tam L, Juchem C, Nixon TW, Constable RT. In vivo O-Space imaging with a dedicated 12 cm Z2 insert coil on a human 3T scanner using phase map calibration. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 69: 444-55. PMID 22585546 DOI: 10.1002/Mrm.24282  0.813
2013 Li S, Galiana G, Tam L, Kozerke S, Stockmann JP, Constable R, Peters DC. Cardiac cine with ART for radial parallel imaging reconstruction Journal of Cardiovascular Magnetic Resonance. 15: E34. DOI: 10.1186/1532-429X-15-S1-E34  0.787
2012 Galiana G, Stockmann JP, Tam L, Peters D, Tagare H, Constable RT. The Role of Nonlinear Gradients in Parallel Imaging: A k-Space Based Analysis. Concepts in Magnetic Resonance. Part a, Bridging Education and Research. 40: 253-267. PMID 26604857 DOI: 10.1002/Cmr.A.21243  0.812
2012 Tam LK, Stockmann JP, Galiana G, Constable RT. Null space imaging: nonlinear magnetic encoding fields designed complementary to receiver coil sensitivities for improved acceleration in parallel imaging. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 68: 1166-75. PMID 22190380 DOI: 10.1002/Mrm.24114  0.825
2012 Galiana G, Stockmann JP, Tam L, Constable RT. Spin dephasing under nonlinear gradients: implications for imaging and field mapping. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 67: 1120-6. PMID 21761447 DOI: 10.1002/Mrm.23085  0.778
2010 Stockmann JP, Ciris PA, Galiana G, Tam L, Constable RT. O-space imaging: Highly efficient parallel imaging using second-order nonlinear fields as encoding gradients with no phase encoding. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 64: 447-56. PMID 20665789 DOI: 10.1002/Mrm.22425  0.813
Show low-probability matches.