J. R. Hadley, Ph.D. - Publications

Affiliations: 
2006 University of Utah, Salt Lake City, UT 
Area:
Electronics and Electrical Engineering, Medical Biophysics, Biomedical Engineering, Radiology

30 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2023 Malmberg MA, Odéen H, Hofstetter LW, Hadley JR, Parker DL. Validation of single reference variable flip angle (SR-VFA) dynamic T mapping with T * correction using a novel rotating phantom. Magnetic Resonance in Medicine. PMID 38115639 DOI: 10.1002/mrm.29944  0.372
2022 Baradaran H, Culleton S, Stoddard G, Alexander MD, Romero JR, Hadley JR, Kim SE, Parker DL, McNally JS. Association between high-risk extracranial carotid plaque and covert brain infarctions and cerebral microbleeds. Neuroradiology. PMID 36278979 DOI: 10.1007/s00234-022-03062-0  0.373
2021 Beck MJ, Parker DL, Hadley JR. Quasistatic Solutions versus Full-Wave Solutions of Single-Channel Circular RF Receive Coils on Phantoms of Varying Conductivities at 3 Tesla. Concepts in Magnetic Resonance. Part B, Magnetic Resonance Engineering. 2021. PMID 34899097 DOI: 10.1155/2021/6638576  0.367
2020 Beck MJ, Parker DL, Hadley JR. Capacitive versus Overlap Decoupling of Adjacent Radio Frequency Phased Array Coil Elements: An Imaging Robustness Comparison When Sample Load Varies for 3 Tesla MRI. Concepts in Magnetic Resonance. Part B, Magnetic Resonance Engineering. 2020. PMID 34867110 DOI: 10.1155/2020/8828047  0.489
2020 Payne A, Minalga E, Merrill R, Parker DL, Hadley JR. Technical Note: Effect of transducer position and ground plane configuration on image quality in MR-guided focused ultrasound therapies. Medical Physics. PMID 32170866 DOI: 10.1002/Mp.14138  0.5
2017 Shea J, de Bever J, Kholmovski E, Beal H, Hadley JR, Minalga E, Salama ME, Marrouche NF, Payne A. Effect of applied energy in renal sympathetic denervation with magnetic resonance guided focused ultrasound in a porcine model. Journal of Therapeutic Ultrasound. 5: 16. PMID 28616236 DOI: 10.1186/S40349-017-0094-Y  0.534
2017 McNally JS, Kim SE, Mendes J, Hadley JR, Sakata A, De Havenon AH, Treiman GS, Parker DL. Magnetic Resonance Imaging Detection of Intraplaque Hemorrhage. Magnetic Resonance Insights. 10: 1-8. PMID 28469441 DOI: 10.1177/1178623X17694150  0.48
2017 Beck MJ, Parker DL, Bolster BD, Kim SE, McNally JS, Treiman GS, Hadley JR. Interchangeable neck shape-specific coils for a clinically realizable anterior neck phased array system. Magnetic Resonance in Medicine. PMID 28185303 DOI: 10.1002/Mrm.26632  0.468
2016 Svedin BT, Beck MJ, Hadley JR, Merrill R, de Bever JT, Bolster BD, Payne A, Parker DL. Focal point determination in magnetic resonance-guided focused ultrasound using tracking coils. Magnetic Resonance in Medicine. PMID 27418429 DOI: 10.1002/Mrm.26294  0.481
2016 Koopmann M, Shea J, Kholmovski E, de Bever J, Minalga E, Holbrook M, Merrill R, Hadley JR, Owan T, Salama ME, Marrouche NF, Payne A. Renal sympathetic denervation using MR-guided high-intensity focused ultrasound in a porcine model. Journal of Therapeutic Ultrasound. 4: 3. PMID 26848390 DOI: 10.1186/S40349-016-0048-9  0.552
2015 Bangerter NK, Kaggie JD, Taylor MD, Hadley JR. Sodium MRI radiofrequency coils for body imaging. Nmr in Biomedicine. PMID 26417667 DOI: 10.1002/Nbm.3392  0.339
2015 Kaggie JD, Goodrich KC, Kim SE, Beck MJ, Parker DL, Merrill R, Abele TA, Wiggins R, Oakley GM, Hadley JR. An improved RF and gradient coil system for high resolution in vivo guinea pig cochlea imaging on a 3T clinical magnet Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering. 44: 89-101. DOI: 10.1002/Cmr.B.21272  0.549
2014 Kaggie JD, Hadley JR, Badal J, Campbell JR, Park DJ, Parker DL, Morrell G, Newbould RD, Wood AF, Bangerter NK. A 3 T sodium and proton composite array breast coil. Magnetic Resonance in Medicine. 71: 2231-42. PMID 24105740 DOI: 10.1002/Mrm.24860  0.459
2014 Parker DL, Payne A, Todd N, Hadley JR. Phase reconstruction from multiple coil data using a virtual reference coil. Magnetic Resonance in Medicine. 72: 563-9. PMID 24006172 DOI: 10.1002/Mrm.24932  0.446
2014 Goodrich KC, Hadley JR, Kim SE, Kaggie JD, Handler WB, Chronik BA, Bolster BD, Parker DL. Peripheral nerve stimulation measures in a composite gradient system Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering. 44: 66-74. DOI: 10.1002/Cmr.B.21269  0.4
2013 Seo HS, Kim SE, Rose J, Hadley JR, Parker DL, Jeong EK. Diffusion tensor imaging of extraocular muscle using two-dimensional single-shot interleaved multiple inner volume imaging diffusion-weighted EPI at 3 tesla. Journal of Magnetic Resonance Imaging : Jmri. 38: 1162-8. PMID 23553830 DOI: 10.1002/Jmri.24095  0.4
2013 Volland NA, Kholmovski EG, Parker DL, Hadley JR. Initial feasibility testing of limited field of view magnetic resonance thermometry using a local cardiac radiofrequency coil. Magnetic Resonance in Medicine. 70: 994-1004. PMID 23165722 DOI: 10.1002/Mrm.24534  0.657
2013 Tate Q, Kim SE, Treiman G, Parker DL, Hadley JR. Increased vessel depiction of the carotid bifurcation with a specialized 16-channel phased array coil at 3T. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 69: 1486-93. PMID 22777692 DOI: 10.1002/Mrm.24380  0.516
2013 Minalga E, Payne A, Merrill R, Todd N, Vijayakumar S, Kholmovski E, Parker DL, Hadley JR. An 11-channel radio frequency phased array coil for magnetic resonance guided high-intensity focused ultrasound of the breast. Magnetic Resonance in Medicine. 69: 295-302. PMID 22431301 DOI: 10.1002/Mrm.24247  0.65
2012 Roberts JA, Kim S, Yoon H, McNally JS, Hadley JR, Findeiss LK, Treiman GS, Parker DL. Reproducibility of Lumen and Vessel Wall Measurements in Carotid Magnetic Resonance Imaging The Open Cardiovascular and Thoracic Surgery Journal. 5: 1-7. DOI: 10.2174/1876533501205010001  0.568
2012 Merrill RP, Hadley JR, Minalga E, Kholmovski EG, Vijayakumar S, Kim SE, Quigley EP, Parker DL, Rose JW. A 28-channel coil array for improved imaging of the optic nerve Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering. 41: 73-84. DOI: 10.1002/Cmr.B.21216  0.644
2011 Kim SE, Treiman GS, Roberts JA, Jeong EK, Shi X, Hadley JR, Parker DL. In vivo and ex vivo measurements of the mean ADC values of lipid necrotic core and hemorrhage obtained from diffusion weighted imaging in human atherosclerotic plaques. Journal of Magnetic Resonance Imaging : Jmri. 34: 1167-75. PMID 21928384 DOI: 10.1002/Jmri.22736  0.435
2011 Moon SM, Goodrich KC, Hadley JR, Kim SE, Zeng GL, Morrell GR, McAlpine MA, Chronik BA, Parker DL. Superelliptical insert gradient coil with a field-modifying layer for breast imaging. Magnetic Resonance in Medicine. 65: 863-72. PMID 20939085 DOI: 10.1002/Mrm.22639  0.504
2009 Parker DL, Goodrich KC, Hadley JR, Kim SE, Moon SM, Chronik BA, Fontius U, Schmitt F. Magnetic Resonance Imaging with Composite (Dual) Gradients. Concepts in Magnetic Resonance. Part B, Magnetic Resonance Engineering. 35: 89-97. PMID 20160925 DOI: 10.1002/Cmr.B.20134  0.496
2009 Goodrich KC, Hadley JR, Moon SM, Chronik BA, Scholl TJ, Debever JT, Parker DL. Design, Fabrication and Testing of an Insertable Double-Imaging-Region Gradient Coil. Concepts in Magnetic Resonance. Part B, Magnetic Resonance Engineering. 35: 98-105. PMID 19830258 DOI: 10.1002/Cmr.B.20138  0.513
2009 Terry CM, Kim SE, Li L, Goodrich KC, Hadley JR, Blumenthal DK, Parker DL, Cheung AK. Longitudinal assessment of hyperplasia using magnetic resonance imaging without contrast in a porcine arteriovenous graft model. Academic Radiology. 16: 96-107. PMID 19064217 DOI: 10.1016/J.Acra.2008.05.019  0.491
2006 Parker DL, Hadley JR. Multiple-region gradient arrays for extended field of view, increased performance, and reduced nerve stimulation in magnetic resonance imaging. Magnetic Resonance in Medicine. 56: 1251-60. PMID 17063472 DOI: 10.1002/Mrm.21063  0.531
2005 Hadley JR, Roberts JA, Goodrich KC, Buswell HR, Parker DL. Relative RF coil performance in carotid imaging. Magnetic Resonance Imaging. 23: 629-39. PMID 16051037 DOI: 10.1016/J.Mri.2005.04.009  0.511
2001 Welker KM, Tsuruda JS, Hadley JR, Hayes CE. Radio-frequency coil selection for MR imaging of the brain and skull base. Radiology. 221: 11-25. PMID 11568316 DOI: 10.1148/radiol.2211001537  0.367
2000 Hadley JR, Chapman BE, Roberts JA, Chapman DC, Goodrich KC, Buswell HR, Alexander AL, Tsuruda JS, Parker DL. A three-coil comparison for MR angiography. Journal of Magnetic Resonance Imaging : Jmri. 11: 458-68. PMID 10767076 DOI: 10.1002/(Sici)1522-2586(200004)11:4<458::Aid-Jmri15>3.0.Co;2-D  0.637
Show low-probability matches.