Karen J. Kirkby - Publications

Affiliations: 
Faculty of Engineering and Physical Sciences, Electronic Engineering University of Surrey (United Kingdom) 
Area:
General Biophysics, General Biology, Radiation Physics, Oncology

66 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2020 Pola A, Bortot D, Mazzucconi D, Fazzi A, Galer S, Kirkby K, Merchant M, Palmans H, Agosteo S. Characterization of a pixelated silicon microdosimeter in micro-beams of light ions Radiation Measurements. 133: 106296. DOI: 10.1016/J.Radmeas.2020.106296  0.376
2019 Smith EAK, Henthorn NT, Warmenhoven JW, Ingram SP, Aitkenhead AH, Richardson JC, Sitch P, Chadwick AL, Underwood TSA, Merchant MJ, Burnet NG, Kirkby NF, Kirkby KJ, Mackay RI. In Silico Models of DNA Damage and Repair in Proton Treatment Planning: A Proof of Concept. Scientific Reports. 9: 19870. PMID 31882690 DOI: 10.1038/S41598-019-56258-5  0.347
2019 Burnet N, Mackay RI, Smith E, Chadwick AL, Whitfield GA, Thomson DJ, Lowe M, Kirkby NF, Crellin AM, Kirkby KJ. Proton beam therapy - perspectives on the National Health Service England clinical service and research programme. The British Journal of Radiology. 20190873. PMID 31860337 DOI: 10.1259/Bjr.20190873  0.359
2019 Panaino CMV, Mackay RI, Kirkby KJ, Taylor MJ. A New Method to Reconstruct in 3D the Emission Position of the Prompt Gamma Rays following Proton Beam Irradiation. Scientific Reports. 9: 18820. PMID 31827167 DOI: 10.1038/S41598-019-55349-7  0.351
2019 Ismael M, Webb R, Ajaz M, Kirkby KJ, Coley HM. The Targeting of RNA Polymerase I Transcription Using CX-5461 in Combination with Radiation Enhances Tumour Cell Killing Effects in Human Solid Cancers. Cancers. 11. PMID 31557908 DOI: 10.3390/Cancers11101429  0.332
2019 Biglin ER, Price GJ, Chadwick AL, Aitkenhead AH, Williams KJ, Kirkby KJ. Preclinical dosimetry: exploring the use of small animal phantoms. Radiation Oncology (London, England). 14: 134. PMID 31366364 DOI: 10.1186/S13014-019-1343-8  0.311
2019 Henthorn NT, Warmenhoven JW, Sotiropoulos M, Aitkenhead AH, Smith EAK, Ingram SP, Kirkby NF, Chadwick A, Burnet NG, Mackay RI, Kirkby KJ, Merchant MJ. Clinically relevant nanodosimetric simulation of DNA damage complexity from photons and protons Rsc Advances. 9: 6845-6858. DOI: 10.1039/C8Ra10168J  0.301
2018 Schuemann J, McNamara AL, Warmenhoven JW, Henthorn NT, Kirkby K, Merchant MJ, Ingram S, Paganetti H, Held KD, Ramos-Mendez J, Faddegon B, Perl J, Goodhead DT, Plante I, Rabus H, et al. A New Standard DNA Damage (SDD) Data Format. Radiation Research. PMID 30407901 DOI: 10.1667/Rr15209.1  0.316
2018 McNamara AL, Ramos-Mendez J, Perl J, Held K, Dominguez N, Moreno EB, Henthorn NT, Kirkby KJ, Meylan S, Villagrasa C, Incerti S, Faddegon B, Paganetti H, Schuemann J. Geometrical structures for radiation biology research as implemented in the TOPAS-nBio toolkit. Physics in Medicine and Biology. PMID 30088810 DOI: 10.1088/1361-6560/Aad8Eb  0.311
2018 Mee T, Kirkby NF, Kirkby KJ. Mathematical Modelling for Patient Selection in Proton Therapy. Clinical Oncology (Royal College of Radiologists (Great Britain)). PMID 29452724 DOI: 10.1016/J.Clon.2018.01.007  0.301
2018 Henthorn NT, Warmenhoven JW, Sotiropoulos M, Mackay RI, Kirkby NF, Kirkby KJ, Merchant MJ. In Silico Non-Homologous End Joining Following Ion Induced DNA Double Strand Breaks Predicts That Repair Fidelity Depends on Break Density. Scientific Reports. 8: 2654. PMID 29422642 DOI: 10.1038/S41598-018-21111-8  0.36
2018 Panaino C, Mackay R, Merchant M, Green S, Phoenix B, Price T, Kirkby K, Taylor M. [OA056] Range uncertainty reduction in proton beam therapy via prompt gamma-ray detection Physica Medica. 52: 23. DOI: 10.1016/J.Ejmp.2018.06.128  0.355
2017 England MJ, Bigelow AW, Merchant MJ, Velliou E, Welch D, Brenner DJ, Kirkby KJ. Automated microbeam observation environment for biological analysis-Custom portable environmental control applied to a vertical microbeam system. Sensors and Actuators. B, Chemical. 239: 1134-1143. PMID 29515291 DOI: 10.1016/J.Snb.2016.08.076  0.322
2017 Sotiropoulos M, Henthorn NT, Warmenhoven JW, Mackay RI, Kirkby KJ, Merchant MJ. Modelling direct DNA damage for gold nanoparticle enhanced proton therapy. Nanoscale. PMID 29148554 DOI: 10.1039/C7Nr07310K  0.302
2017 Henthorn NT, Warmenhoven JW, Sotiropoulos M, Mackay RI, Kirkby KJ, Merchant MJ. Nanodosimetric Simulation of Direct Ion-Induced DNA Damage Using Different Chromatin Geometry Models. Radiation Research. PMID 28792846 DOI: 10.1667/Rr14755.1  0.334
2017 Sotiropoulos M, Taylor MJ, Henthorn NT, Warmenhoven JW, Mackay RI, Kirkby KJ, Merchant MJ. Geant4 interaction model comparison for dose deposition from gold nanoparticles under proton irradiation Biomedical Physics & Engineering Express. 3: 025025. DOI: 10.1088/2057-1976/Aa69Cc  0.318
2017 Fathi K, Galer S, Kirkby K, Palmans H, Nisbet A. Coupling Monte Carlo simulations with thermal analysis for correcting microdosimetric spectra from a novel micro-calorimeter Radiation Physics and Chemistry. 140: 406-411. DOI: 10.1016/J.Radphyschem.2017.02.055  0.351
2017 Galer S, Shipley D, Palmans H, Kirkby K, Nisbet A. Monte Carlo simulation of a TEPC for microdosimetry of carbon ions Radiation Physics and Chemistry. 140: 412-418. DOI: 10.1016/J.Radphyschem.2017.02.028  0.358
2016 Kanellopoulos V, Kirkby NF, Jena R, Dosanjh M, Kirkby KJ. An analytical model of tumour response to radiotherapy to investigate biological parameters of chordoma treated by X-rays, protons and carbon ions Physica Medica. 32: 254. DOI: 10.1016/J.Ejmp.2016.07.544  0.356
2015 Barazzuol L, Jeynes JC, Merchant MJ, Wéra AC, Barry MA, Kirkby KJ, Suzuki M. Radiosensitization of glioblastoma cells using a histone deacetylase inhibitor (SAHA) comparing carbon ions with X-rays. International Journal of Radiation Biology. 91: 90-8. PMID 25040548 DOI: 10.3109/09553002.2014.946111  0.668
2015 Warmenhoven J, Demarche J, Palitsin V, Kirkby K, Webb R. Modeling Transport of Secondary Ion Fragments into a Mass Spectrometer Physics Procedia. 66: 352-360. DOI: 10.1016/J.Phpro.2015.05.044  0.312
2014 Jeynes JCG, Merchant MJ, Spindler A, Wera AC, Kirkby KJ. Investigation of gold nanoparticle radiosensitization mechanisms using a free radical scavenger and protons of different energies Physics in Medicine and Biology. 59: 6431-6443. PMID 25296027 DOI: 10.1088/0031-9155/59/21/6431  0.357
2014 Wéra AC, Barazzuol L, Jeynes JC, Merchant MJ, Suzuki M, Kirkby KJ. Influence of the nucleus area distribution on the survival fraction after charged particles broad beam irradiation. Physics in Medicine and Biology. 59: 4197-211. PMID 25017303 DOI: 10.1088/0031-9155/59/15/4197  0.692
2013 Jeynes JC, Merchant MJ, Barazzuol L, Barry M, Guest D, Palitsin VV, Grime GW, Tullis ID, Barber PR, Vojnovic B, Kirkby KJ. "Broadbeam" irradiation of mammalian cells using a vertical microbeam facility. Radiation and Environmental Biophysics. 52: 513-21. PMID 23963461 DOI: 10.1007/S00411-013-0487-4  0.71
2013 Romolo FS, Christopher ME, Donghi M, Ripani L, Jeynes C, Webb RP, Ward NI, Kirkby KJ, Bailey MJ. Integrated Ion Beam Analysis (IBA) in Gunshot Residue (GSR) characterisation. Forensic Science International. 231: 219-28. PMID 23890641 DOI: 10.1016/J.Forsciint.2013.05.006  0.319
2013 Christopher ME, Warmenhoeven JW, Romolo FS, Donghi M, Webb RP, Jeynes C, Ward NI, Kirkby KJ, Bailey MJ. A new quantitative method for gunshot residue analysis by ion beam analysis. The Analyst. 138: 4649-55. PMID 23775063 DOI: 10.1039/C3An00597F  0.309
2013 Barazzuol L, Jena R, Burnet NG, Meira LB, Jeynes JC, Kirkby KJ, Kirkby NF. Evaluation of poly (ADP-ribose) polymerase inhibitor ABT-888 combined with radiotherapy and temozolomide in glioblastoma. Radiation Oncology (London, England). 8: 65. PMID 23510353 DOI: 10.1186/1748-717X-8-65  0.665
2013 Hanton F, Doria D, Kakolee KF, Kar S, Litt SK, Fiorini F, Ahmed H, Green S, Jeynes JCG, Kavanagh J, Kirby D, Kirkby KJ, Lewis CL, Merchant MJ, Nersisyan G, et al. Radiobiology at ultra-high dose rates employing laser-driven ions Proceedings of Spie - the International Society For Optical Engineering. 8779. DOI: 10.1117/12.2017565  0.389
2013 Prakrajang K, Jeynes J, Merchant M, Kirkby K, Kirkby N, Thopan P, Yu L. MeV single-ion beam irradiation of mammalian cells using the Surrey vertical nanobeam, compared with broad proton beam and X-ray irradiations Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions With Materials and Atoms. 307: 586-591. DOI: 10.1016/J.Nimb.2013.02.043  0.416
2012 Merchant MJ, Jeynes JC, Grime GW, Palitsin V, Tullis ID, Barber PR, Vojnovic B, Webb RP, Kirkby KJ. A focused scanning vertical beam for charged particle irradiation of living cells with single counted particles. Radiation Research. 178: 182-90. PMID 22823572 DOI: 10.1667/Rr2847.1  0.399
2012 Barazzuol L, Jena R, Burnet NG, Jeynes JC, Merchant MJ, Kirkby KJ, Kirkby NF. In vitro evaluation of combined temozolomide and radiotherapy using X  rays and high-linear energy transfer radiation for glioblastoma. Radiation Research. 177: 651-62. PMID 22468703 DOI: 10.1667/Rr2803.1  0.704
2012 Doria D, Kakolee KF, Kar S, Litt SK, Fiorini F, Ahmed H, Green S, Jeynes JCG, Kavanagh J, Kirby D, Kirkby KJ, Lewis CL, Merchant MJ, Nersisyan G, Prasad R, et al. Biological effectiveness on live cells of laser driven protons at dose rates exceeding 109 Gy/s Aip Advances. 2. DOI: 10.1063/1.3699063  0.368
2012 Khamsuwan J, Intarasiri S, Kirkby K, Chu P, Singkarat S, Yu L. Ion-beam synthesis and photoluminescence of SiC nanocrystals assisted by MeV-heavy-ion-beam annealing Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions With Materials and Atoms. 282: 88-91. DOI: 10.1016/J.Nimb.2011.08.058  0.382
2011 Galer S, Hao L, Gallop J, Palmans H, Kirkby K, Nisbet A. Design concept for a novel SQUID-based microdosemeter. Radiation Protection Dosimetry. 143: 427-31. PMID 21186221 DOI: 10.1093/Rpd/Ncq475  0.345
2011 Green JS, Borghesi M, Brenner CM, Carroll DC, Dover NP, Foster PS, Gallegos P, Green S, Kirby D, Kirkby KJ, McKenna P, Merchant MJ, Najmudin Z, Palmer CAJ, Parker D, et al. Scintillator-based ion beam profiler for diagnosing laser-accelerated ion beams Proceedings of Spie - the International Society For Optical Engineering. 8079. DOI: 10.1117/12.888967  0.372
2011 Borghesi M, Kar S, Prasad R, Kakolee FK, Quinn K, Ahmed H, Sarri G, Ramakrishna B, Qiao B, Geissler M, Ter-Avetisyan S, Zepf M, Schettino G, Stevens B, Tolley M, ... ... Kirkby K, et al. Ion source development and radiobiology applications within the LIBRA project Proceedings of Spie - the International Society For Optical Engineering. 8079. DOI: 10.1117/12.888262  0.357
2011 Green S, Borghesi M, Neely D, McKenna P, Najmudin Z, Palmer C, Sari I, Tolley M, Ward A, Carroll D, Kar S, Doria D, Green J, Brenner C, Kirby D, ... ... Kirkby K, et al. 1425 poster LASER-PLASMA ACCELERATION OF PARTICLES FOR PROTON AND ION-BEAM RADIOTHERAPY: AN UPDATE FROM THE LIBRA CONSORTIUM Radiotherapy and Oncology. 99: S530. DOI: 10.1016/S0167-8140(11)71547-X  0.342
2011 Galer S, Palmans H, Shipley D, Hao L, Nisbet A, Kirkby K. 1112 poster A NOVEL DETECTOR FOR THE MEASUREMENT OF MICRODOSI-METRIC SPECTRA FOR PROTONS AND LIGHT IONS Radiotherapy and Oncology. 99: S414. DOI: 10.1016/S0167-8140(11)71234-8  0.302
2011 Barazzuol L, Burnet N, Jena R, Jeynes J, Merchant M, Kirkby K, Kirkby N. 940 poster EVALUATION OF COMBINED TEMOZOLOMIDE AND HIGH LINEAR ENERGY TRANSFER RADIATION IN GLIOBLASTOMA CELL LINES Radiotherapy and Oncology. 99: S360. DOI: 10.1016/S0167-8140(11)71062-3  0.671
2011 Khamsuwan J, Intarasiri S, Kirkby K, Jeynes C, Chu P, Kamwanna T, Yu L. High-energy heavy ion beam annealing effect on ion beam synthesis of silicon carbide Surface and Coatings Technology. 206: 770-774. DOI: 10.1016/J.Surfcoat.2011.04.058  0.381
2010 Jena R, Jeynes C, Peacock J, Thomas C, Duane S, Burnet N, Kirkby K, Stancanello J. SU-GG-T-487: Lack of Dose Rate Effect with Ultra-High Dose Rate Irradiation of Normal Tissue Fibroblasts and RT112 Tumour Cells Medical Physics. 37: 3299-3299. DOI: 10.1118/1.3468885  0.341
2010 Giubertoni D, Pepponi G, Sahiner MA, Kelty SP, Gennaro S, Bersani M, Kah M, Kirkby KJ, Doherty R, Foad MA, Meirer F, Streli C, Woicik JC, Pianetta P. Deactivation of submelt laser annealed arsenic ultrashallow junctions in silicon during subsequent thermal treatment Journal of Vacuum Science and Technology B: Microelectronics and Nanometer Structures. 28: C1B1-C1B5. DOI: 10.1116/1.3242637  0.346
2009 Richard M, Webb RP, Kirkby KJ, Kirkby NF. A computer model of the Bystander effect: Effects of individual behaviours on the population response Applied Radiation and Isotopes. 67: 440-442. PMID 18845443 DOI: 10.1016/J.Apradiso.2008.06.037  0.345
2009 Richard M, Kirkby KJ, Webb RP, Kirkby NF. Cellular automaton model of cell response to targeted radiation Applied Radiation and Isotopes. 67: 443-446. PMID 18824365 DOI: 10.1016/J.Apradiso.2008.06.044  0.342
2009 Jeynes JCG, Webb M, Kirkby KJ, Kirkby NF, Bradley DA. Proceedings of the First International Conference on Biomedical Applications of High Energy Ion Beams Applied Radiation and Isotopes. 67: 369-370. PMID 18684632 DOI: 10.1016/J.Apradiso.2008.06.011  0.35
2009 Stennett MC, Hyatt NC, Reid DP, Maddrell ER, Peng N, Jeynes C, Kirkby KJ, Woicik JC, Ravel B. Heavy ion implantation combined with grazing incidence X-ray absorption spectroscopy (GIXAS): A new methodology for the characterisation of radiation damage in nuclear ceramics Materials Research Society Symposium Proceedings. 1193: 67-72. DOI: 10.1557/Proc-1193-67  0.378
2009 Bailey MJ, Howard KT, Kirkby KJ, Jeynes C. Characterisation of inhomogeneous inclusions in Darwin glass using ion beam analysis Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions With Materials and Atoms. 267: 2219-2224. DOI: 10.1016/J.Nimb.2009.03.013  0.329
2009 Bailey MJ, Kirkby KJ, Jeynes C. Trace element profiling of gunshot residues by PIXE and SEM-EDS: a feasibility study X-Ray Spectrometry. 38: 190-194. DOI: 10.1002/Xrs.1142  0.347
2008 Folkard M, Prise KM, Grime G, Kirkby K, Vojnovic B. The use of microbeams to investigate radiation damage in living cells. Applied Radiation and Isotopes : Including Data, Instrumentation and Methods For Use in Agriculture, Industry and Medicine. 67: 436-9. PMID 18710814 DOI: 10.1016/J.Apradiso.2008.06.015  0.374
2007 Ferri M, Solmi S, Giubertoni D, Bersani M, Hamilton JJ, Kah M, Kirkby K, Collart EJH, Cowern NE. Uphill diffusion of ultralow-energy boron implants in preamorphized silicon and silicon-on-insulator Journal of Applied Physics. 102: 103707. DOI: 10.1063/1.2812676  0.32
2007 Peng N, Jeynes C, Gwilliam RM, Kirkby KJ, Webb RP. Depth profile analysis for MgB2 thin films, formed by B implantation in Mg ribbons using energetic ion backscatterings Physica C: Superconductivity and Its Applications. 460: 600-601. DOI: 10.1016/J.Physc.2007.04.120  0.304
2007 Mistry P, Gomez-Morilla I, Smith RC, Thomson D, Grime GW, Webb RP, Gwilliam R, Jeynes C, Cansell A, Merchant M, Kirkby KJ. Maskless proton beam writing in gallium arsenide Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions With Materials and Atoms. 260: 437-441. DOI: 10.1016/J.Nimb.2007.02.059  0.347
2007 Rombouts PMM, Gomez-Morilla I, Grime GW, Webb RP, Cuenca L, Rodriguez R, Browton M, Wardell N, Underwood B, Kirkby NF, Kirkby KJ. A microPIXE investigation of the interaction of cells of Schizosaccharomyces pombe with the culture medium Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions With Materials and Atoms. 260: 231-235. DOI: 10.1016/J.Nimb.2007.02.026  0.302
2007 Kirkby KJ, Grime GW, Webb RP, Kirkby NF, Folkard M, Prise K, Vojnovic B. A scanning focussed vertical ion nanobeam: A new UK facility for cell irradiation and analysis Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions With Materials and Atoms. 260: 97-100. DOI: 10.1016/J.Nimb.2007.01.281  0.387
2007 Richard M, Kirkby KJ, Webb RP, Kirkby NF. A mathematical model of response of cells to radiation Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions With Materials and Atoms. 255: 18-22. DOI: 10.1016/J.Nimb.2006.11.077  0.334
2006 Hamilton JJ, Collart EJH, Colombeau B, Bersani M, Giubertoni D, Kah M, Cowern NEB, Kirkby KJ. Effect of B dose and Ge preamorphization energy on the electrical and structural properties of ultrashallow junctions in silicon-on-insulator Materials Research Society Symposium Proceedings. 912: 45-50. DOI: 10.1557/Proc-0912-C01-10  0.3
2006 Mistry P, Gomez-Morilla I, Grime GW, Webb R, Jeynes C, Gwilliam R, Cansell A, Merchant M, Kirkby KJ. Proton beam lithography at the University of Surrey's Ion Beam Centre Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions With Materials and Atoms. 242: 387-389. DOI: 10.1016/J.Nimb.2005.08.128  0.353
2005 Peng N, Jeynes C, Gwilliam RM, Kirkby KJ, Webb RP, Shao G, Astill DM, Liang WY. A potential integrated low temperature approach for superconducting MgB2 thin film growth and electronics device fabrication by ion implantation Ieee Transactions On Applied Superconductivity. 15: 3265-3268. DOI: 10.1109/Tasc.2005.848848  0.317
2005 Mistry P, Gomez-Morilla I, Grime GW, Webb RP, Gwilliam R, Cansell A, Merchant M, Kirkby KJ, Teo EJ, Breese MBH, Bettiol AA, Blackwood DJ, Watt F. New developments in the applications of proton beam writing Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions With Materials and Atoms. 237: 188-192. DOI: 10.1016/J.Nimb.2005.04.099  0.317
2005 Mistry P, Gomez-Morilla I, Grime GW, Webb R, Jeynes C, Gwilliam R, Cansell A, Merchant M, Kirkby KJ. New developments on the Surrey microbeam applications to lithography Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions With Materials and Atoms. 231: 428-432. DOI: 10.1016/J.Nimb.2005.01.095  0.328
2005 Merchant MJ, Mistry P, Browton M, Clough AS, Gauntlett FE, Jeynes C, Kirkby KJ, Grime GW. Characterisation of the University of Surrey Ion Beam Centre in-air scanning microbeam Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions With Materials and Atoms. 231: 26-31. DOI: 10.1016/J.Nimb.2005.01.029  0.367
2004 Burnet N, Kirkby K, Kirkby N. Biomedical applications of high-energy ion beams. Clinical Oncology. 16: 381. PMID 15341447 DOI: 10.1016/J.Clon.2004.05.004  0.349
2004 Claudio G, Kirkby KJ, Bersani M, Low R, Sealy BJ, Gwilliam R. Effect of the tilt angle on antimony in silicon implanted wafers Journal of Applied Physics. 95: 5471-5474. DOI: 10.1063/1.1702096  0.312
2004 Collart EJH, Felch SB, Graoui H, Kirkwood D, Tallavarjula S, Van Den Berg JA, Hamilton J, Cowern NEB, Kirkby KJ. Advanced front-end processes for the 45 nm CMOS technology node Materials Science and Engineering B: Solid-State Materials For Advanced Technology. 114: 118-129. DOI: 10.1016/J.Mseb.2004.07.018  0.321
2003 Webb RP, Winston SH, Gwilliam RM, Sealy BJ, Boudreault G, Jeynes C, Kirkby KJ. Comparison of boron halide, decaborane and B implants in Si from molecular dynamics simulations Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions With Materials and Atoms. 202: 143-148. DOI: 10.1016/S0168-583X(02)01844-X  0.306
2002 McKinty CN, Kirkby KJ, Homewood KP, Edwards SP, Shao G, Valizadeh R, Colligon JS. The properties of β-FeSi2 fabricated by ion beam assisted deposition as a function of annealing conditions for use in solar cell applications Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions With Materials and Atoms. 188: 179-182. DOI: 10.1016/S0168-583X(01)01071-0  0.318
Show low-probability matches.