Cahit Karanfil, Ph.D. - Publications

Affiliations: 
2003 Illinois Institute of Technology, Chicago, IL, United States 
Area:
Optics Physics

12 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2016 Bassey B, Martinson M, Samadi N, Belev G, Karanfil C, Qi P, Chapman D. Multiple energy synchrotron biomedical imaging system. Physics in Medicine and Biology. 61: 8180-8198. PMID 27804925 DOI: 10.1088/0031-9155/61/23/8180  0.394
2012 Karanfil C, Bunker G, Newville M, Segre CU, Chapman D. Quantitative performance measurements of bent crystal Laue analyzers for X-ray fluorescence spectroscopy. Journal of Synchrotron Radiation. 19: 375-80. PMID 22514172 DOI: 10.1107/S0909049512003937  0.67
2011 Kujala NG, Karanfil C, Barrea RA. High resolution short focal distance Bent Crystal Laue Analyzer for copper K edge x-ray absorption spectroscopy. The Review of Scientific Instruments. 82: 063106. PMID 21721673 DOI: 10.1063/1.3595675  0.396
2011 Karanfil C, Barrea RA. Non-isotropic angular distribution of Yb Lα1and Lα2lines following photoionization by linearly polarized radiation Journal of Physics B: Atomic, Molecular and Optical Physics. 44: 235002. DOI: 10.1088/0953-4075/44/23/235002  0.417
2010 Barrea RA, Gore D, Kujala N, Karanfil C, Kozyrenko S, Heurich R, Vukonich M, Huang R, Paunesku T, Woloschak G, Irving TC. Fast-scanning high-flux microprobe for biological X-ray fluorescence microscopy and microXAS. Journal of Synchrotron Radiation. 17: 522-9. PMID 20567085 DOI: 10.1107/S0909049510016869  0.6
2005 Kropf AJ, Fortner JA, Finch RJ, Cunnane JC, Karanfil C. A Bent Silicon Crystal in the Laue Geometry to Resolve Actinide XRay Fluorescence for XRay Absorption Spectroscopy Physica Scripta. 2005: 998. DOI: 10.1238/Physica.Topical.115A00998  0.537
2005 Barrea RA, Fischetti R, Stepanov S, Rosenbaum G, Kondrashkina E, Bunker GB, Black E, Zhang K, Gore D, Heurich R, Vukonich M, Karanfil C, Kropf AJ, Wang S, Irving TC. Biological XAFS at the BioCAT undulator beamline 18ID at the APS Physica Scripta T. 867-869. DOI: 10.1238/Physica.Topical.115A00867  0.686
2004 Lee S, Anderson PR, Bunker GB, Karanfil C. EXAFS study of Zn sorption mechanisms on montmorillonite. Environmental Science & Technology. 38: 5426-32. PMID 15543747 DOI: 10.1021/Es0350076  0.586
2004 Karanfil C, Chapman D, Segre CU, Bunker G. A device for selecting and rejecting X-ray harmonics in synchrotron radiation beams. Journal of Synchrotron Radiation. 11: 393-8. PMID 15310955 DOI: 10.1107/S0909049504016711  0.635
2003 Kropf AJ, Finch RJ, Fortner JA, Aase S, Karanfil C, Segre CU, Terry J, Bunker G, Chapman LD. Bent silicon crystal in the Laue geometry to resolve x-ray fluorescence for x-ray absorption spectroscopy Review of Scientific Instruments. 74: 4696-4702. DOI: 10.1063/1.1618014  0.692
2002 Karanfil C, Chapman LD, Segre CU, Bunker GB. Double crystal bent Laue "beam cleaner" (abstract) Review of Scientific Instruments. 73: 1505. DOI: 10.1063/1.1448156  0.5
2002 Karanfil C, Chapman D, Bunker G, Segre C. Initial results on logarithmic spiral bent laue analyzer for fluorescence x-ray absorption spectroscopy (abstract) Review of Scientific Instruments. 73: 1616. DOI: 10.1063/1.1448128  0.681
Show low-probability matches.