Year |
Citation |
Score |
2024 |
Saad F, Frysch R, Saalfeld S, Kellnberger S, Schulz J, Fahrig R, Bhadra K, Nürnberger A, Rose G. Deformable 3D/3D CT-to-digital-tomosynthesis image registration in image-guided bronchoscopy interventions. Computers in Biology and Medicine. 171: 108199. PMID 38394801 DOI: 10.1016/j.compbiomed.2024.108199 |
0.394 |
|
2023 |
Supanich M, Siewerdsen J, Fahrig R, Farahani K, Gang GJ, Helm P, Jans J, Jones K, Koenig T, Kuhls-Gilcrist A, Lin M, Riddell C, Ritschl L, Schafer S, Schueler B, et al. AAPM Task Group Report 238: 3D C-Arms with Volumetric Imaging Capability. Medical Physics. PMID 36710257 DOI: 10.1002/mp.16245 |
0.351 |
|
2022 |
Wang A, Cunningham I, Danielsson M, Fahrig R, Flohr T, Hoeschen C, Noo F, Sabol JM, Siewerdsen JH, Tingberg A, Yorkston J, Zhao W, Samei E. Science and practice of imaging physics through 50 years of SPIE Medical Imaging conferences. Journal of Medical Imaging (Bellingham, Wash.). 9: 012205. PMID 35309720 DOI: 10.1117/1.JMI.9.S1.012205 |
0.317 |
|
2021 |
Fahrig R, Jaffray DA, Sechopoulos I, Webster Stayman J. Flat-panel conebeam CT in the clinic: history and current state. Journal of Medical Imaging (Bellingham, Wash.). 8: 052115. PMID 34722795 DOI: 10.1117/1.JMI.8.5.052115 |
0.352 |
|
2021 |
Hariharan SG, Kaethner C, Strobel N, Kowarschik M, Fahrig R, Navab N. Robust learning-based X-ray image denoising - potential pitfalls, their analysis and solutions. Biomedical Physics & Engineering Express. PMID 34714256 DOI: 10.1088/2057-1976/ac3489 |
0.302 |
|
2021 |
Maier J, Maier A, Eskofier B, Fahrig R, Choi JH. 3D Non-Rigid Alignment of Low-Dose Scans Allows to Correct for Saturation in Lower Extremity Cone-Beam CT. Ieee Access : Practical Innovations, Open Solutions. 9: 71821-71831. PMID 34141516 DOI: 10.1109/access.2021.3079368 |
0.389 |
|
2019 |
Gao H, Zhang L, Grimmer R, Fahrig R. Physics-based spectral compensation algorithm for X-ray CT with primary modulator. Physics in Medicine and Biology. PMID 30999285 DOI: 10.1088/1361-6560/Ab1Ad0 |
0.392 |
|
2019 |
Hariharan SG, Strobel N, Kaethner C, Kowarschik M, Fahrig R, Navab N. An analytical approach for the simulation of realistic low-dose fluoroscopic images. International Journal of Computer Assisted Radiology and Surgery. PMID 30779022 DOI: 10.1007/S11548-019-01912-6 |
0.302 |
|
2018 |
Lindsay C, Bazalova-Carter M, Wang A, Shedlock D, Wu M, Newson M, Xing L, Ansbacher W, Fahrig R, Star-Lack J. Investigation of combined kV/MV CBCT imaging with a high-DQE MV detector. Medical Physics. PMID 30428131 DOI: 10.1002/Mp.13291 |
0.446 |
|
2018 |
Hariharan SG, Strobel N, Kaethner C, Kowarschik M, Demirci S, Albarqouni S, Fahrig R, Navab N. A photon recycling approach to the denoising of ultra-low dose X-ray sequences. International Journal of Computer Assisted Radiology and Surgery. PMID 29637486 DOI: 10.1007/S11548-018-1746-2 |
0.321 |
|
2018 |
Bier B, Ravikumar N, Unberath M, Levenston M, Gold G, Fahrig R, Maier A. Range Imaging for Motion Compensation in C-Arm Cone-Beam CT of Knees under Weight-Bearing Conditions Journal of Imaging. 4: 13. DOI: 10.3390/Jimaging4010013 |
0.394 |
|
2017 |
Wang J, Trovati S, Borchard PM, Loo BW, Maxim PG, Fahrig R. Thermal limits on MV x-ray production by bremsstrahlung targets in the context of novel linear accelerators. Medical Physics. PMID 28983960 DOI: 10.1002/Mp.12615 |
0.327 |
|
2017 |
Ahmad M, Fahrig R, Pung L, Spahn M, Köster NS, Reitz S, Moore T, Choi JH, Hinshaw W, Xia Y, Müller K. Assessment of a photon-counting detector for a dual-energy C-arm angiographic system. Medical Physics. PMID 28940528 DOI: 10.1002/Mp.12517 |
0.31 |
|
2017 |
Maier J, Black M, Bonaretti S, Bier B, Eskofier B, Choi JH, Levenston M, Gold G, Fahrig R, Maier A. Comparison of Different Approaches for Measuring Tibial Cartilage Thickness. Journal of Integrative Bioinformatics. 14. PMID 28753537 DOI: 10.1515/Jib-2017-0015 |
0.348 |
|
2017 |
Berger M, Xia Y, Aichinger W, Mentl K, Unberath M, Aichert A, Riess C, Hornegger J, Fahrig R, Maier AK. Motion compensation for cone-beam CT using Fourier consistency conditions. Physics in Medicine and Biology. PMID 28741597 DOI: 10.1088/1361-6560/Aa8129 |
0.377 |
|
2017 |
Gao H, Zhu L, Fahrig R. Virtual scatter modulation for X-ray CT scatter correction using primary modulator. Journal of X-Ray Science and Technology. PMID 28582954 DOI: 10.3233/Xst-17251 |
0.386 |
|
2017 |
Datta S, Müller K, Moore T, Molvin L, Gehrisch S, Rosenberg J, Saenz Y, Manhart M, Deuerling-Zheng Y, Kothary N, Fahrig R. Dynamic Measurement of Arterial Liver Perfusion With an Interventional C-Arm System. Investigative Radiology. PMID 28306699 DOI: 10.1097/Rli.0000000000000368 |
0.307 |
|
2017 |
Bier B, Berger M, Maier A, Kachelrieß M, Ritschl L, Műller K, Choi JH, Fahrig R. Scatter Correction Using a Primary Modulator on a Clinical Angiography C-arm CT System. Medical Physics. PMID 28061010 DOI: 10.1002/Mp.12094 |
0.354 |
|
2016 |
Siewerdsen J, Fahrig R. WE-DE-207A-00: Advances in Image-Guided Neurointerventions-Clinical Pull and Technology Push. Medical Physics. 43: 3815-3816. PMID 28048454 DOI: 10.1118/1.4957845 |
0.325 |
|
2016 |
Bazalova-Carter M, Wang A, Wu M, Newson M, Xing L, Ansbacher W, Fahrig R, Star-Lack J. SU-D-BRA-07: Applications of Combined KV/MV CBCT Imaging with a High-DQE MV Detector. Medical Physics. 43: 3340-3341. PMID 28046211 DOI: 10.1118/1.4955640 |
0.359 |
|
2016 |
Nelson G, Wu M, Hinkel C, Krishna G, Funk T, Rosenberg J, Fahrig R. Improved targeting accuracy of lung tumor biopsies with scanning-beam digital x-ray tomosynthesis image guidance. Medical Physics. 43: 6282. PMID 27908166 DOI: 10.1118/1.4966025 |
0.478 |
|
2016 |
Müller K, Datta S, Ahmad M, Choi JH, Moore T, Pung L, Niebler C, Gold GE, Maier A, Fahrig R. Interventional dual-energy imaging-Feasibility of rapid kV-switching on a C-arm CT system. Medical Physics. 43: 5537. PMID 27782692 DOI: 10.1118/1.4962929 |
0.421 |
|
2016 |
Mueller K, Fahrig R, Manhart M, Deuerling-Zheng Y, Rosenberg J, Moore T, Ganguly A, Kothary N. Reproducibility of Parenchymal Blood Volume Measurements Using an Angiographic C-arm CT System. Academic Radiology. PMID 27745815 DOI: 10.1016/J.Acra.2016.08.001 |
0.38 |
|
2016 |
Rausch J, Maier A, Fahrig R, Choi JH, Hinshaw W, Schebesch F, Haase S, Wasza J, Hornegger J, Riess C. Kinect-Based Correction of Overexposure Artifacts in Knee Imaging with C-Arm CT Systems. International Journal of Biomedical Imaging. 2016: 2502486. PMID 27516772 DOI: 10.1155/2016/2502486 |
0.427 |
|
2016 |
Whelan B, Gierman S, Holloway L, Schmerge J, Keall P, Fahrig R. A novel electron accelerator for MRI-Linac radiotherapy. Medical Physics. 43: 1285. PMID 26936713 DOI: 10.1118/1.4941309 |
0.325 |
|
2016 |
Berger M, Müller K, Aichert A, Unberath M, Thies J, Choi JH, Fahrig R, Maier A. Marker-free motion correction in weight-bearing cone-beam CT of the knee joint. Medical Physics. 43: 1235. PMID 26936708 DOI: 10.1118/1.4941012 |
0.392 |
|
2016 |
Taubmann O, Maier A, Hornegger J, Lauritsch G, Fahrig R. Coping with real world data: Artifact reduction and denoising for motion-compensated cardiac C-arm CT. Medical Physics. 43: 883. PMID 26843249 DOI: 10.1118/1.4939878 |
0.39 |
|
2016 |
Müller K, Datta S, Ahmad M, Choi JH, Moore T, Pung L, Niebler C, Gold GE, Maier A, Fahrig R. Interventional dual-energy imaging - Feasibility of rapid kV-switching on a C-arm CT system Medical Physics. 43: 5537-5546. DOI: 10.1118/1.4962929 |
0.318 |
|
2016 |
Choi J, Muller K, Hsieh S, Maier A, Gold G, Levenston M, Fahrig R. Over-exposure correction in knee cone-beam CT imaging with automatic exposure control using a partial low dose scan Proceedings of Spie. 9783. DOI: 10.1117/12.2217347 |
0.449 |
|
2016 |
Choi J, McWalter E, Datta S, Mueller K, Maier A, Fahrig R, Levenston M, Gold G. Tibial cartilage creep during weight bearing: in vivo 3D CT assessment Osteoarthritis and Cartilage. 24: S104. DOI: 10.1016/J.Joca.2016.01.210 |
0.316 |
|
2015 |
Bazalova-Carter M, Ahmad M, Xing L, Fahrig R. Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study. Journal of Medical Imaging (Bellingham, Wash.). 2: 043501. PMID 26839910 DOI: 10.1117/1.Jmi.2.4.043501 |
0.435 |
|
2015 |
Cherry Kemmerling EM, Wu M, Yang H, Maxim PG, Loo BW, Fahrig R. Optimization of an on-board imaging system for extremely rapid radiation therapy. Medical Physics. 42: 6757. PMID 26520765 DOI: 10.1118/1.4934377 |
0.394 |
|
2015 |
Star-Lack J, Shedlock D, Swahn D, Humber D, Wang A, Hirsh H, Zentai G, Sawkey D, Kruger I, Sun M, Abel E, Virshup G, Shin M, Fahrig R. A piecewise-focused high DQE detector for MV imaging. Medical Physics. 42: 5084. PMID 26328960 DOI: 10.1118/1.4927786 |
0.45 |
|
2015 |
Choi JH, Constantin D, Ganguly A, Girard E, Morin RL, Dixon RL, Fahrig R. Practical dose point-based methods to characterize dose distribution in a stationary elliptical body phantom for a cone-beam C-arm CT system. Medical Physics. 42: 4920. PMID 26233218 DOI: 10.1118/1.4927257 |
0.351 |
|
2015 |
Wu M, Yoon S, Solomon E, Star-Lack J, Pelc N, Fahrig R. Digital Tomosynthesis System Geometry Analysis Using Convolution-based Blur-and-add (BAA) Model. Ieee Transactions On Medical Imaging. PMID 26208308 DOI: 10.1109/Tmi.2015.2458983 |
0.678 |
|
2015 |
Bazalova-Carter M, Ahmad M, Matsuura T, Takao S, Matsuo Y, Fahrig R, Shirato H, Umegaki K, Xing L. TH-AB-204-11: X-Ray Fluorescence CT Induced by Proton Beam: Experiments and Simulations. Medical Physics. 42: 3716. PMID 26129479 DOI: 10.1118/1.4926178 |
0.483 |
|
2015 |
Bazalova-Carter M, Ahmad M, Xing L, Fahrig R. TH-AB-204-09: High-Sensitivity L-Shell X-Ray Fluorescence CT Imaging of Gold. Medical Physics. 42: 3715. PMID 26129475 DOI: 10.1118/1.4926176 |
0.423 |
|
2015 |
Herbst M, Schebesch F, Berger M, Choi JH, Fahrig R, Hornegger J, Maier A. Dynamic detector offsets for field of view extension in C-arm computed tomography with application to weight-bearing imaging. Medical Physics. 42: 2718. PMID 25979070 DOI: 10.1118/1.4915542 |
0.426 |
|
2015 |
Bazalova-Carter M, Ahmad M, Matsuura T, Takao S, Matsuo Y, Fahrig R, Shirato H, Umegaki K, Xing L. Proton-induced x-ray fluorescence CT imaging. Medical Physics. 42: 900-7. PMID 25652502 DOI: 10.1118/1.4906169 |
0.442 |
|
2015 |
Girard EE, Al-Ahmad A, Rosenberg J, Luong R, Moore T, Lauritsch G, Chan F, Lee DP, Fahrig R. Contrast-Enhanced C-arm Computed Tomography Imaging of Myocardial Infarction in the Interventional Suite. Investigative Radiology. 50: 384-91. PMID 25635589 DOI: 10.1097/Rli.0000000000000138 |
0.43 |
|
2015 |
Ritschl L, Fahrig R, Knaup M, Maier J, Kachelrieß M. Robust primary modulation-based scatter estimation for cone-beam CT. Medical Physics. 42: 469-78. PMID 25563286 DOI: 10.1118/1.4903261 |
0.399 |
|
2015 |
Ahmad M, Bazalova-Carter M, Fahrig R, Xing L. Optimized Detector Angular Configuration Increases the Sensitivity of X-ray Fluorescence Computed Tomography (XFCT). Ieee Transactions On Medical Imaging. 34: 1140-7. PMID 25474808 DOI: 10.1109/Tmi.2014.2376813 |
0.433 |
|
2015 |
Star-Lack J, Shedlock D, Swahn D, Humber D, Wang A, Hirsh H, Zentai G, Sawkey D, Kruger I, Sun M, Abel E, Virshup G, Shin M, Fahrig R. A piecewise-focused high DQE detector for MV imaging Medical Physics. 42: 5084-5099. DOI: 10.1118/1.4927786 |
0.304 |
|
2015 |
Fahrig R. WE-EF-BRD-04: MR in the OR: The Growth and Applications of MRI for Interventional Radiology and Surgery Medical Physics. 42: 3673-3674. DOI: 10.1118/1.4925967 |
0.362 |
|
2015 |
Fahrig R. TU-AB-204-02: Advances in C-Arm CBCT for Cardiac Interventions Medical Physics. 42: 3592-3593. DOI: 10.1118/1.4925532 |
0.458 |
|
2015 |
Choi JH, Constantin D, Fahrig R. A numerical investigation for the optimal positions and weighting coefficients of point dose measurements in the weighted CTDI Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9412. DOI: 10.1117/12.2082477 |
0.33 |
|
2015 |
Riess C, Mohamed A, Hinshaw W, Fahrig R. On filtration for high-energy phase-contrast x-ray imaging Proceedings of Spie. 9412: 941251. DOI: 10.1117/12.2082354 |
0.369 |
|
2015 |
Unberath M, Choi JH, Berger M, Maier AK, Fahrig R. Image-based compensation for involuntary motion in weight-bearing C-arm cone-beam CT scanning of knees Proceedings of Spie. 9413. DOI: 10.1117/12.2081559 |
0.444 |
|
2015 |
Cherry EM, Fahrig R. Comparison of CT scatter rejection effectiveness using antiscatter grids and energy-discriminating detectors Progress in Biomedical Optics and Imaging - Proceedings of Spie. 9412. DOI: 10.1117/12.2081538 |
0.354 |
|
2015 |
Wu M, Yang Q, Maier A, Fahrig R. Approximate path seeking for statistical iterative reconstruction Proceedings of Spie. 9412. DOI: 10.1117/12.2081442 |
0.446 |
|
2015 |
Bazalova-Carter M, Ahmad M, Matsuura T, Takao S, Matsuo Y, Fahrig R, Shirato H, Umegaki K, Xing L. PD-0140: Proton induced x-ray fluorescence CT (pXFCT) imaging: a step towards proton beam range detection Radiotherapy and Oncology. 115: S66-S67. DOI: 10.1016/S0167-8140(15)40138-0 |
0.411 |
|
2015 |
Bazalova M, Ahmad M, Xing L, Fahrig R. X-ray Fluorescence Imaging of Superficial Malignancies Using Gold Nanoparticles International Journal of Radiation Oncology*Biology*Physics. 93: S190. DOI: 10.1016/J.Ijrobp.2015.07.455 |
0.337 |
|
2014 |
Bazalova M, Ahmad M, Fahrig R, Xing L. TU-A-9A-09: Proton Beam X-Ray Fluorescence CT. Medical Physics. 41: 449. PMID 28037715 DOI: 10.1118/1.4889244 |
0.417 |
|
2014 |
Ahmad M, Bazalova M, Fahrig R, Xing L. TU-A-9A-05: First Experimental Demonstration of the Anisotropic Detection Principle in X-Ray Fluorescence Computed Tomography. Medical Physics. 41: 448. PMID 28037641 DOI: 10.1118/1.4889240 |
0.396 |
|
2014 |
Wu M, Loo B, Bazalova M, Star-Lack J, Fahrig R. WE-G-18A-02: Calibration-Free Combined KV/MV Short Scan CBCT. Medical Physics. 41: 526. PMID 28037044 DOI: 10.1118/1.4889513 |
0.404 |
|
2014 |
Wu M, Keil A, Constantin D, Star-Lack J, Zhu L, Fahrig R. Metal artifact correction for x-ray computed tomography using kV and selective MV imaging. Medical Physics. 41: 121910. PMID 25471970 DOI: 10.1118/1.4901551 |
0.437 |
|
2014 |
Lillaney P, Shin M, Hinshaw W, Fahrig R. Electrostatic focal spot correction for x-ray tubes operating in strong magnetic fields. Medical Physics. 41: 112302. PMID 25370658 DOI: 10.1118/1.4898099 |
0.359 |
|
2014 |
Wu M, Fahrig R. Real-time out-of-plane artifact subtraction tomosynthesis imaging using prior CT for scanning beam digital x-ray system. Medical Physics. 41: 111905. PMID 25370638 DOI: 10.1118/1.4896818 |
0.537 |
|
2014 |
Choi JH, Maier A, Keil A, Pal S, McWalter EJ, Beaupré GS, Gold GE, Fahrig R. Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment. Medical Physics. 41: 061902. PMID 24877813 DOI: 10.1118/1.4873675 |
0.406 |
|
2014 |
Müller K, Maier AK, Schwemmer C, Lauritsch G, De Buck S, Wielandts JY, Hornegger J, Fahrig R. Image artefact propagation in motion estimation and reconstruction in interventional cardiac C-arm CT. Physics in Medicine and Biology. 59: 3121-38. PMID 24840084 DOI: 10.1088/0031-9155/59/12/3121 |
0.477 |
|
2014 |
Müller K, Maier AK, Zheng Y, Wang Y, Lauritsch G, Schwemmer C, Rohkohl C, Hornegger J, Fahrig R. Interventional heart wall motion analysis with cardiac C-arm CT systems. Physics in Medicine and Biology. 59: 2265-84. PMID 24731942 DOI: 10.1088/0031-9155/59/9/2265 |
0.397 |
|
2014 |
Star-Lack J, Sun M, Meyer A, Morf D, Constantin D, Fahrig R, Abel E. Rapid Monte Carlo simulation of detector DQE(f). Medical Physics. 41: 031916. PMID 24593734 DOI: 10.1118/1.4865761 |
0.325 |
|
2014 |
Constantin DE, Holloway L, Keall PJ, Fahrig R. A novel electron gun for inline MRI-linac configurations. Medical Physics. 41: 022301. PMID 24506639 DOI: 10.1118/1.4860660 |
0.302 |
|
2014 |
Whelan B, Constantin D, Holloway L, Kolling S, Oborn B, Fahrig R, Keall P. WE-G-17A-08: Electron Gun Operation for in Line MRI-Linac Configurations: An Assessment of Beam Fidelity and Recovery Techniques for Different SIDs and Magnetic Field Strengths Medical Physics. 41: 525-526. DOI: 10.1118/1.4889510 |
0.317 |
|
2014 |
Choi J, Maier A, Berger M, Fahrig R. Effective One Step-iterative Fiducial Marker-based Compensation for Involuntary Motion in Weight-bearing C-arm Cone-beam CT Scanning of Knees Proceedings of Spie. 9033: 903312. DOI: 10.1117/12.2043771 |
0.417 |
|
2014 |
Wu M, Yang Q, Maier A, Fahrig R. A Practical Statistical Polychromatic Image Reconstruction for Computed Tomography Using Spectrum Binning Proceedings of Spie. 9033. DOI: 10.1117/12.2043370 |
0.403 |
|
2014 |
Coletti F, Benson MJ, Sagues AL, Miller BH, Fahrig R, Eaton JK. Three-dimensional mass fraction distribution of a spray measured by X-ray computed tomography Journal of Engineering For Gas Turbines and Power. 136. DOI: 10.1115/1.4026245 |
0.402 |
|
2013 |
Star-Lack J, Shedlock D, Abel E, Sun M, Shin M, Fahrig R, Virshup G. TH-A-141-10: A Piecewise-Focused Pixelated Detector for MV Imaging. Medical Physics. 40: 524. PMID 28519677 DOI: 10.1118/1.4815715 |
0.426 |
|
2013 |
Choi JH, Constantin D, Nelson G, Ganguly A, Girard E, Morin R, Dixon R, Fahrig R. SU-D-103-02: Image Quality Assurance Study of a Cone-Beam C-Arm CT with Automatic Exposure Control for Body Applications. Medical Physics. 40: 110. PMID 28519573 DOI: 10.1118/1.4814040 |
0.456 |
|
2013 |
Choi JH, Constantin D, Nelson G, Fahrig R. SU-D-103-07: Dose Measurement and Estimation Methods in An Elliptical Body Phantom for a Conebeam CT System. Medical Physics. 40: 112. PMID 28519565 DOI: 10.1118/1.4814045 |
0.326 |
|
2013 |
Abel E, Meyer A, Sun M, Sawkey D, Fahrig R, Morf D, Star-Lack J. TH-A-141-11: Standardization of DQE(f) Measurements at MV Energies. Medical Physics. 40: 525. PMID 28517905 DOI: 10.1118/1.4815716 |
0.333 |
|
2013 |
Nelson G, Yoon S, Krishna G, Wilfley B, Fahrig R. Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs. Medical Physics. 40: 111917. PMID 24320450 DOI: 10.1118/1.4826159 |
0.68 |
|
2013 |
Maier A, Hofmann HG, Berger M, Fischer P, Schwemmer C, Wu H, Müller K, Hornegger J, Choi JH, Riess C, Keil A, Fahrig R. CONRAD--a software framework for cone-beam imaging in radiology. Medical Physics. 40: 111914. PMID 24320447 DOI: 10.1118/1.4824926 |
0.442 |
|
2013 |
Shin M, Lillaney P, Hinshaw W, Fahrig R. Design optimization of MR-compatible rotating anode x-ray tubes for stable operation. Medical Physics. 40: 111913. PMID 24320446 DOI: 10.1118/1.4824325 |
0.378 |
|
2013 |
Choi JH, Fahrig R, Keil A, Besier TF, Pal S, McWalter EJ, Beaupré GS, Maier A. Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. Part I. Numerical model-based optimization. Medical Physics. 40: 091905. PMID 24007156 DOI: 10.1118/1.4817476 |
0.366 |
|
2013 |
Bögel M, Hofmann HG, Hornegger J, Fahrig R, Britzen S, Maier A. Respiratory Motion Compensation Using Diaphragm Tracking for Cone-Beam C-Arm CT: A Simulation and a Phantom Study. International Journal of Biomedical Imaging. 2013: 520540. PMID 23840198 DOI: 10.1155/2013/520540 |
0.397 |
|
2013 |
Müller K, Schwemmer C, Hornegger J, Zheng Y, Wang Y, Lauritsch G, Rohkohl C, Maier AK, Schultz C, Fahrig R. Evaluation of interpolation methods for surface-based motion compensated tomographic reconstruction for cardiac angiographic C-arm data. Medical Physics. 40: 031107. PMID 23464287 DOI: 10.1118/1.4789593 |
0.397 |
|
2013 |
Lillaney P, Shin M, Hinshaw W, Bennett NR, Pelc N, Fahrig R. Novel motor design for rotating anode x-ray tubes operating in the fringe field of a magnetic resonance imaging system. Medical Physics. 40: 022302. PMID 23387764 DOI: 10.1118/1.4773313 |
0.393 |
|
2013 |
Abel E, Sun M, Constantin D, Fahrig R, Star-Lack J. User-friendly, ultra-fast simulation of detector DQE(f) Progress in Biomedical Optics and Imaging - Proceedings of Spie. 8668. DOI: 10.1117/12.2008411 |
0.318 |
|
2013 |
Kothary N, Ganguly A, Blum K, Deuerling-Zheng Y, Rosenberg J, Moore T, Manhart M, Fahrig R. Measurement of hepatic blood flow using C-arm CT imaging Journal of Vascular and Interventional Radiology. 24: S11. DOI: 10.1016/J.Jvir.2013.01.029 |
0.395 |
|
2012 |
Constantin D, Sun M, Abel E, Star-Lack J, Fahrig R. WE-C-217BCD-11: Coupled Radiative and Optical Geant4 Simulation of MV EPIDs Based on Thick Pixelated Scintillating Crystals. Medical Physics. 39: 3951-3952. PMID 28520011 DOI: 10.1118/1.4736127 |
0.38 |
|
2012 |
Lillaney P, Shin M, Hinshaw W, Fahrig R. WE-C-217BCD-02: Design of an MR Compatible Rotating Anode X-Ray Tube. Medical Physics. 39: 3949. PMID 28519982 DOI: 10.1118/1.4736118 |
0.315 |
|
2012 |
Choi JH, Keil A, Maier A, Pal S, McWalter EJ, Fahrig R. WE-G-217BCD-05: Fiducial Marker-Based Motion Compensation for the Acquisition of 3D Knee Geometry Under Weight-Bearing Conditions Using a C-Arm CT Scanner. Medical Physics. 39: 3973. PMID 28519650 DOI: 10.1118/1.4736213 |
0.4 |
|
2012 |
Keil A, Zhu L, Star-Lack J, Fahrig R. SU-E-I-22: Metal Artifact Correction Using KV and Selective MV Imaging. Medical Physics. 39: 3629. PMID 28519536 DOI: 10.1118/1.4734737 |
0.427 |
|
2012 |
Ganguly A, Abel E, Sun M, Fahrig R, Virshup G, Star-Lack J. TU-E-BRA-05: Reverse Geometry Imaging with MV Detector for Improved Image Resolution. Medical Physics. 39: 3911. PMID 28518708 DOI: 10.1118/1.4735965 |
0.411 |
|
2012 |
Nelson G, Yoon S, Krishna G, Wilfley B, Fahrig R. SU-E-I-80: Optimizing Scanning-Beam Digital X-Ray Tomosynthesis of the Lungs. Medical Physics. 39: 3643. PMID 28517627 DOI: 10.1118/1.4734797 |
0.444 |
|
2012 |
Shin M, Lillaney P, Hinshaw W, Fahrig R. SU-D-218-03: Resonant Frequency of Rotating Anode X-Ray Tubes. Medical Physics. 39: 3622. PMID 28517407 DOI: 10.1118/1.4734706 |
0.317 |
|
2012 |
Ganguly A, Fieselmann A, Boese J, Rohkohl C, Hornegger J, Fahrig R. In vitro evaluation of the imaging accuracy of C-arm conebeam CT in cerebral perfusion imaging. Medical Physics. 39: 6652-9. PMID 23127059 DOI: 10.1118/1.4757910 |
0.475 |
|
2012 |
Starman J, Star-Lack J, Virshup G, Shapiro E, Fahrig R. A nonlinear lag correction algorithm for a-Si flat-panel x-ray detectors. Medical Physics. 39: 6035-47. PMID 23039642 DOI: 10.1118/1.4752087 |
0.376 |
|
2012 |
Maier A, Hofmann HG, Schwemmer C, Hornegger J, Keil A, Fahrig R. Fast simulation of x-ray projections of spline-based surfaces using an append buffer. Physics in Medicine and Biology. 57: 6193-210. PMID 22975431 DOI: 10.1088/0031-9155/57/19/6193 |
0.436 |
|
2012 |
Lillaney P, Shin M, Conolly SM, Fahrig R. Magnetostatic focal spot correction for x-ray tubes operating in strong magnetic fields using iterative optimization. Medical Physics. 39: 5567-83. PMID 22957623 DOI: 10.1118/1.4742060 |
0.363 |
|
2012 |
Grimmer R, Fahrig R, Hinshaw W, Gao H, Kachelriess M. Empirical cupping correction for CT scanners with primary modulation (ECCP). Medical Physics. 39: 825-31. PMID 22320792 DOI: 10.1118/1.3676180 |
0.404 |
|
2012 |
Starman J, Tognina C, Partain L, Fahrig R. A forward bias method for lag correction of an a-Si flat panel detector Medical Physics. 39: 18-27. PMID 22225271 DOI: 10.1118/1.3664004 |
0.379 |
|
2012 |
Fieselmann A, Ganguly A, Deuerling-Zheng Y, Zellerhoff M, Rohkohl C, Boese J, Hornegger J, Fahrig R. Interventional 4-D C-arm CT perfusion imaging using interleaved scanning and partial reconstruction interpolation. Ieee Transactions On Medical Imaging. 31: 892-906. PMID 22203707 DOI: 10.1109/Tmi.2011.2181531 |
0.44 |
|
2012 |
Star-Lack J, Etmektzoglou T, Davidi R, Abel E, Sun M, Virshup G, Kielar K, Fahrig R. TH-C-BRA-12: Tomographic Measurement of X-Ray Beam Spot Profiles Using a Rotating Edge Medical Physics. 39: 4002-4002. DOI: 10.1118/1.4736328 |
0.437 |
|
2012 |
Wu H, Maier A, Fahrig R, Hornegger J. Spatial-temporal total variation regularization (STTVR) for 4D-CT reconstruction Proceedings of Spie. 8313. DOI: 10.1117/12.911162 |
0.429 |
|
2012 |
Girard E, Moore T, Lauritsch G, Rosenberg J, Al-Ahmad A, Chan F, Lee D, Fahrig R. CONTRAST-ENHANCED ROTATIONAL ANGIOGRAPHIC C-ARM CT IMAGING OF MYOCARDIAL INFARCTION IN THE INTERVENTIONAL SUITE: OPTIMIZED IMAGING PROTOCOL FOR ACUTE AND CHRONIC INFARCTS Journal of the American College of Cardiology. 59: E169. DOI: 10.1016/S0735-1097(12)60170-3 |
0.377 |
|
2012 |
Ganguly A, Kothary N, Blum K, Moore T, Deuerling-Zheng Y, Fieselmann A, Fahrig R. Abstract No. 237: Measurement of hepatic perfusion blood volume using C-arm CT Journal of Vascular and Interventional Radiology. 23: S97. DOI: 10.1016/J.Jvir.2011.12.288 |
0.314 |
|
2011 |
Maier A, Wigstrom L, Hofmann HG, Hornegger J, Zhu L, Strobel N, Fahrig R. Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT. Medical Physics. 38: 5896-909. PMID 22047354 DOI: 10.1118/1.3633901 |
0.442 |
|
2011 |
Fieselmann A, Kowarschik M, Ganguly A, Hornegger J, Fahrig R. Deconvolution-Based CT and MR Brain Perfusion Measurement: Theoretical Model Revisited and Practical Implementation Details. International Journal of Biomedical Imaging. 2011: 467563. PMID 21904538 DOI: 10.1155/2011/467563 |
0.38 |
|
2011 |
Kothary N, Abdelmaksoud MH, Tognolini A, Fahrig R, Rosenberg J, Hovsepian DM, Ganguly A, Louie JD, Kuo WT, Hwang GL, Holzer A, Sze DY, Hofmann LV. Imaging guidance with C-arm CT: prospective evaluation of its impact on patient radiation exposure during transhepatic arterial chemoembolization. Journal of Vascular and Interventional Radiology : Jvir. 22: 1535-43. PMID 21875814 DOI: 10.1016/J.Jvir.2011.07.008 |
0.337 |
|
2011 |
Constantin DE, Fahrig R, Keall PJ. A study of the effect of in-line and perpendicular magnetic fields on beam characteristics of electron guns in medical linear accelerators. Medical Physics. 38: 4174-85. PMID 21859019 DOI: 10.1118/1.3600695 |
0.307 |
|
2011 |
Starman J, Star-Lack J, Virshup G, Shapiro E, Fahrig R. Investigation into the optimal linear time-invariant lag correction for radar artifact removal. Medical Physics. 38: 2398-411. PMID 21776774 DOI: 10.1118/1.3574873 |
0.375 |
|
2011 |
Ganguly A, Fieselmann A, Marks M, Rosenberg J, Boese J, Deuerling-Zheng Y, Straka M, Zaharchuk G, Bammer R, Fahrig R. Cerebral CT perfusion using an interventional C-arm imaging system: cerebral blood flow measurements. Ajnr. American Journal of Neuroradiology. 32: 1525-31. PMID 21757522 DOI: 10.3174/Ajnr.A2518 |
0.399 |
|
2011 |
Fieselmann A, Dennerlein F, Deuerling-Zheng Y, Boese J, Fahrig R, Hornegger J. A model for filtered backprojection reconstruction artifacts due to time-varying attenuation values in perfusion C-arm CT. Physics in Medicine and Biology. 56: 3701-17. PMID 21617289 DOI: 10.1088/0031-9155/56/12/016 |
0.406 |
|
2011 |
Tognolini A, Al-Ahmad A, Wang PJ, Hsia HH, Herfkens RJ, Girard E, Moore T, Fahrig R. Intraprocedure visualization of the esophagus using interventional C-arm CT as guidance for left atrial radiofrequency ablation. Academic Radiology. 18: 850-7. PMID 21440465 DOI: 10.1016/J.Acra.2011.01.023 |
0.335 |
|
2011 |
Girard EE, Al-Ahmad A, Rosenberg J, Luong R, Moore T, Lauritsch G, Boese J, Fahrig R. Contrast-enhanced C-arm CT evaluation of radiofrequency ablation lesions in the left ventricle. Jacc. Cardiovascular Imaging. 4: 259-68. PMID 21414574 DOI: 10.1016/J.Jcmg.2010.11.019 |
0.41 |
|
2011 |
Ganguly A, Simons J, Schneider A, Keck B, Bennett NR, Herfkens RJ, Coogan SM, Fahrig R. In-vivo imaging of femoral artery nitinol stents for deformation analysis. Journal of Vascular and Interventional Radiology : Jvir. 22: 244-9. PMID 21276917 DOI: 10.1016/J.Jvir.2010.10.019 |
0.304 |
|
2011 |
Constantin D, Holloway L, Keall PJ, Fahrig R. WE-G-214-05: Robotic Linac Adaptation (RLA) with a Novel Electron Gun Design for the In-Line MRI-Linac Configuration Medical Physics. 38: 3831-3831. DOI: 10.1118/1.3613426 |
0.361 |
|
2011 |
Lillaney P, Constantin D, Ganguly A, Fahrig R. SU‐C‐220‐04: Electrostatic Focal Spot Correction for X‐Ray Tubes Operating in Strong Magnetic Fields Medical Physics. 38: 3380-3380. DOI: 10.1118/1.3611510 |
0.333 |
|
2011 |
Gao H, Niu T, Zhu L, Fahrig R. Evaluation of an erbium modulator in x-ray scatter correction using primary modulation Proceedings of Spie. 7961: 796122. DOI: 10.1117/12.878609 |
0.359 |
|
2011 |
Maier A, Choi JH, Keil A, Niebler C, Sarmiento M, Fieselmann A, Gold G, Delp S, Fahrig R. Analysis of vertical and horizontal circular C-arm trajectories Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7961. DOI: 10.1117/12.878502 |
0.423 |
|
2011 |
Yoon S, Wilfley BP, Jasperson K, Krishna G, Fahrig R. Real-time scanning beam digital x-ray image guidance system for transbronchial needle biopsy Proceedings of Spie. 7961. DOI: 10.1117/12.878167 |
0.69 |
|
2011 |
Fieselmann A, Ganguly A, Yu D, Boese J, Hornegger J, Fahrig R. Automatic measurement of contrast bolus distribution in carotid arteries using a C-arm angiography system to support interventional perfusion imaging Proceedings of Spie. 7964. DOI: 10.1117/12.877658 |
0.394 |
|
2010 |
Gao H, Zhu L, Fahrig R. Modulator design for x-ray scatter correction using primary modulation: material selection. Medical Physics. 37: 4029-37. PMID 20879564 DOI: 10.1118/1.3457472 |
0.352 |
|
2010 |
Yoon S, Pineda AR, Fahrig R. Simultaneous segmentation and reconstruction: a level set method approach for limited view computed tomography. Medical Physics. 37: 2329-40. PMID 20527567 DOI: 10.1118/1.3397463 |
0.631 |
|
2010 |
Ganguly A, Yoon S, Fahrig R. Dose and detectability for a cone-beam C-arm CT system revisited. Medical Physics. 37: 2264-8. PMID 20527560 DOI: 10.1118/1.3397465 |
0.664 |
|
2010 |
Gao H, Fahrig R, Bennett NR, Sun M, Star-Lack J, Zhu L. Scatter correction method for x-ray CT using primary modulation: phantom studies. Medical Physics. 37: 934-46. PMID 20229902 DOI: 10.1118/1.3298014 |
0.416 |
|
2010 |
Zhu L, Wang J, Xie Y, Starman J, Fahrig R, Xing L. A patient set-up protocol based on partially blocked cone-beam CT Technology in Cancer Research and Treatment. 9: 191-198. PMID 20218741 DOI: 10.1177/153303461000900208 |
0.46 |
|
2010 |
Fahrig R, Girard-Hughes E, Ganguly A, Tognolini A, Kothary N. WE-A-202-01: Dose and Image Quality in C-Arm CT Rotational Angiography Medical Physics. 37: 3413-3414. DOI: 10.1118/1.3469339 |
0.448 |
|
2010 |
Constantin D, Fahrig R, Keall P. TU-B-204B-02: A Study of the Effect of Inline and Perpendicular Magnetic Fields on Beam Characteristics of Medical Linear Accelerator Electron Guns Medical Physics. 37: 3376-3376. DOI: 10.1118/1.3469191 |
0.318 |
|
2010 |
Starman J, Star-Lack J, Fahrig R. SU-GG-I-09: Efficacy of a Linear Lag Correction Algorithm in an A-Si Flat-Panel X-Ray Detector Medical Physics. 37: 3103-3103. DOI: 10.1118/1.3468042 |
0.372 |
|
2010 |
Ganguly A, Fieselmann A, Boese JM, Rohkohl C, Hornegger J, Fahrig R. Evaluating the feasibility of C-arm CT for brain perfusion imaging: an in vitro study Proceedings of Spie. 7625. DOI: 10.1117/12.845386 |
0.467 |
|
2010 |
Gao H, Zhu L, Fahrig R. Optimization of system parameters for modulator design in x-ray scatter correction using primary modulation Proceedings of Spie. 7622. DOI: 10.1117/12.843984 |
0.39 |
|
2010 |
Tognolini A, Kothary N, Fahrig R, Abdelmaksoud M, Hwang G, Louie J, Hofmann L, Sze D. Abstract No. 120: Imaging guidance with c-arm CT (CACT) for transhepatic arterial chemoembolization: A prospective, randomized study evaluating the impact of CACT on patient radiation exposure Journal of Vascular and Interventional Radiology. 21: S47-S48. DOI: 10.1016/J.Jvir.2009.12.273 |
0.383 |
|
2009 |
Prümmer M, Hornegger J, Lauritsch G, Wigström L, Girard-Hughes E, Fahrig R. Cardiac C-arm CT: a unified framework for motion estimation and dynamic CT. Ieee Transactions On Medical Imaging. 28: 1836-49. PMID 19884068 DOI: 10.1109/Tmi.2009.2025499 |
0.41 |
|
2009 |
Bracken JA, DeCrescenzo G, Komljenovic P, Lillaney PV, Fahrig R, Rowlands JA. Closed bore XMR (CBXMR) systems for aortic valve replacement: active magnetic shielding of x-ray tubes. Medical Physics. 36: 1717-26. PMID 19544789 DOI: 10.1118/1.3116363 |
0.378 |
|
2009 |
Bracken JA, Komljenovic P, Lillaney PV, Fahrig R, Rowlands JA. Closed-bore XMR (CBXMR) systems for aortic valve replacement: x-ray tube imaging performance. Medical Physics. 36: 1086-97. PMID 19472613 DOI: 10.1118/1.3086188 |
0.388 |
|
2009 |
Yerushalmi D, Mullick R, Quon A, Fahrig R, Pelc NJ, Fann JI, Gambhir SS. Simulations of virtual PET/CT 3-D bronchoscopy imaging using a physical porcine lung-heart phantom. Molecular Imaging and Biology : Mib : the Official Publication of the Academy of Molecular Imaging. 11: 275-82. PMID 19434462 DOI: 10.1007/S11307-009-0201-8 |
0.372 |
|
2009 |
Pauly KB, Sawant A, Fahrig R, Keall P. WE-D-BRC-01: MR Imaging for Real-Time Radiotherapy Guidance Medical Physics. 36: 2774-2774. DOI: 10.1118/1.3182524 |
0.406 |
|
2009 |
Gao H, Watkins R, Zhu L, Fahrig R. MO‐D‐304A‐05: Optimal Material Selection of Primary Modulator for Scatter Correction Based On the K‐Edge Discontinuity Medical Physics. 36: 2698-2698. DOI: 10.1118/1.3182234 |
0.312 |
|
2009 |
Zhu L, Gao H, Bennett NR, Xinga L, Fahrig R. Scatter correction for x-ray conebeam CT using one-dimensional primary modulation Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7258. DOI: 10.1117/12.813849 |
0.402 |
|
2009 |
Yoon S, Gang JG, Tward DJ, Siewerdsen JH, Fahrig R. Analysis of lung nodule detectability and anatomical clutter in tomosynthesis imaging of the chest Progress in Biomedical Optics and Imaging - Proceedings of Spie. 7258. DOI: 10.1117/12.813836 |
0.667 |
|
2009 |
Girard-Hughes E, Al-Ahmad A, Moore T, Lauritsch G, Boese J, Fahrig R. Visualization and enhancement patterns of radiofrequency ablation lesions with iodine contrast-enhanced cardiac C-arm CT Proceedings of Spie. 7262. DOI: 10.1117/12.812947 |
0.397 |
|
2008 |
Yoon S, Henry RW, Bouley DM, Bennett NR, Fahrig R. Characterization of a novel anthropomorphic plastinated lung phantom. Medical Physics. 35: 5934-43. PMID 19175148 DOI: 10.1118/1.3016524 |
0.67 |
|
2008 |
Zhu L, Starman J, Fahrig R. An efficient estimation method for reducing the axial intensity drop in circular cone-beam CT. International Journal of Biomedical Imaging. 2008: 242841. PMID 18923681 DOI: 10.1155/2008/242841 |
0.378 |
|
2008 |
Bracken JA, Lillaney PV, Fahrig R, Rowlands JA. Closed bore XMR (CBXMR) systems for aortic valve replacement: investigation of rotating-anode x-ray tube heat loadability. Medical Physics. 35: 4049-62. PMID 18841857 DOI: 10.1118/1.2968337 |
0.348 |
|
2008 |
Wen Z, Fahrig R, Williams ST, Pelc NJ. Shimming with permanent magnets for the x-ray detector in a hybrid x-ray/ MR system. Medical Physics. 35: 3895-902. PMID 18841840 DOI: 10.1118/1.2963994 |
0.321 |
|
2008 |
Al-Ahmad A, Wigström L, Sandner-Porkristl D, Wang PJ, Zei PC, Boese J, Lauritsch G, Moore T, Chan F, Fahrig R. Time-resolved three-dimensional imaging of the left atrium and pulmonary veins in the interventional suite--a comparison between multisweep gated rotational three-dimensional reconstructed fluoroscopy and multislice computed tomography. Heart Rhythm : the Official Journal of the Heart Rhythm Society. 5: 513-9. PMID 18362018 DOI: 10.1016/J.Hrthm.2007.12.027 |
0.417 |
|
2008 |
Freeman-Walsh CB, Fahrig R, Ganguly A, Rieke V, Daniel BL. A hybrid radiography/MRI system for combining hysterosalpingography and MRI in infertility patients: initial experience. Ajr. American Journal of Roentgenology. 190: W157-60. PMID 18212200 DOI: 10.2214/Ajr.07.2282 |
0.308 |
|
2008 |
Arakawa H, Marks MP, Do HM, Bouley DM, Strobel N, Moore T, Fahrig R. Experimental study of intracranial hematoma detection with flat panel detector C-arm CT. Ajnr. American Journal of Neuroradiology. 29: 766-72. PMID 18202240 DOI: 10.3174/Ajnr.A0898 |
0.412 |
|
2008 |
Fahrig R. TH‐SAMS‐332‐03: Design and Performance Evaluation of Cone Beam CT Systems : Cone Beam Angio CT Medical Physics. 35: 2963-2963. DOI: 10.1118/1.2962815 |
0.466 |
|
2008 |
Hristov D, Moore T, Sarmiento M, Fahrig R, Gibbs I, Marks M, Dodd R, Do H. WE-D-351-02: Feasibility Study of Frameless Angiographic Localization of Arteriovenous Malformations (AVMs) for Image-Guided Radiosurgical Interventions Medical Physics. 35: 2946-2946. DOI: 10.1118/1.2962746 |
0.43 |
|
2008 |
Fahrig R. TU-C-342-01: Image Guidance During Minimally Invasive Cardiac Interventions : Beyond Fluoroscopy Medical Physics. 35: 2896-2896. DOI: 10.1118/1.2962554 |
0.416 |
|
2008 |
Zhu L, Wang J, Xie Y, Starman J, Fahrig R, Xing L. SU-GG-I-14: A Patient Set-Up Protocol Based On Partially Blocked Cone-Beam CT Medical Physics. 35: 2645-2646. DOI: 10.1118/1.2961413 |
0.457 |
|
2007 |
Zhu L, Yoon S, Fahrig R. A short-scan reconstruction for cone-beam CT using shift-invariant FBP and equal weighting. Medical Physics. 34: 4422-38. PMID 18072507 DOI: 10.1118/1.2789405 |
0.627 |
|
2007 |
Wen Z, Fahrig R, Conolly S, Pelc NJ. Investigation of electron trajectories of an x-ray tube in magnetic fields of MR scanners. Medical Physics. 34: 2048-58. PMID 17654908 DOI: 10.1118/1.2733798 |
0.354 |
|
2007 |
Sommer G, Bouley D, Frisoli J, Pierce L, Sandner-Porkristl D, Fahrig R. Determination of 3-dimensional zonal renal volumes using contrast-enhanced computed tomography. Journal of Computer Assisted Tomography. 31: 209-13. PMID 17414755 DOI: 10.1097/01.Rct.0000236423.12890.D6 |
0.332 |
|
2007 |
Wen Z, Pelc NJ, Nelson WR, Fahrig R. Study of increased radiation when an x-ray tube is placed in a strong magnetic field. Medical Physics. 34: 408-18. PMID 17388157 DOI: 10.1118/1.2404618 |
0.343 |
|
2007 |
Fahrig R, Siewerdsen J, Jaffray D, Boone J. WE-D-L100E-01: Cone Beam CT Workshop Medical Physics. 34: 2605-2605. DOI: 10.1118/1.2761574 |
0.424 |
|
2007 |
Fahrig R. MO-A-M100J-03: Performance Evaluation for New-Technology CT Systems: Cone Beam C-Arm CT Medical Physics. 34: 2510-2510. DOI: 10.1118/1.2761191 |
0.465 |
|
2006 |
Fahrig R, Dixon R, Payne T, Morin RL, Ganguly A, Strobel N. Dose and image quality for a cone-beam C-arm CT system. Medical Physics. 33: 4541-50. PMID 17278805 DOI: 10.1118/1.2370508 |
0.436 |
|
2006 |
Zhu L, Bennett NR, Fahrig R. Scatter correction method for X-ray CT using primary modulation: theory and preliminary results. Ieee Transactions On Medical Imaging. 25: 1573-87. PMID 17167993 DOI: 10.1109/Tmi.2006.884636 |
0.442 |
|
2006 |
Brzozowski L, Ganguly A, Pop M, Wen Z, Bennett R, Fahrig R, Rowlands JA. Compatibility of interventional x-ray and magnetic resonance imaging: feasibility of a closed bore XMR (CBXMR) system. Medical Physics. 33: 3033-45. PMID 16964881 DOI: 10.1118/1.2219328 |
0.367 |
|
2006 |
Schmidt TG, Star-Lack J, Bennett NR, Mazin SR, Solomon EG, Fahrig R, Pelc NJ. A prototype table-top inverse-geometry volumetric CT system. Medical Physics. 33: 1867-78. PMID 16872094 DOI: 10.1118/1.2192887 |
0.506 |
|
2006 |
Lauritsch G, Boese J, Wigström L, Kemeth H, Fahrig R. Towards cardiac C-arm computed tomography. Ieee Transactions On Medical Imaging. 25: 922-34. PMID 16827492 DOI: 10.1109/Tmi.2006.876166 |
0.481 |
|
2006 |
Pineda AR, Yoon S, Paik DS, Fahrig R. Optimization of a tomosynthesis system for the detection of lung nodules. Medical Physics. 33: 1372-9. PMID 16752573 DOI: 10.1118/1.2190329 |
0.647 |
|
2006 |
Sze DY, Strobel N, Fahrig R, Moore T, Busque S, Frisoli JK. Transjugular intrahepatic portosystemic shunt creation in a polycystic liver facilitated by hybrid cross-sectional/angiographic imaging. Journal of Vascular and Interventional Radiology : Jvir. 17: 711-5. PMID 16614155 DOI: 10.1097/01.Rvi.0000208984.17697.58 |
0.416 |
|
2006 |
Starman J, Virshup G, Bandy S, Star-Lack J, Fahrig R. TH-E-330A-04: Investigation Into the Cause of a New Artifact in Cone Beam CT Reconstructions On a Flat Panel Imager Medical Physics. 33: 2288-2288. DOI: 10.1118/1.2241936 |
0.473 |
|
2006 |
Fahrig R. MO-E-ValB-02: Hybrid Imaging for Guidance of Interventional Procedures Medical Physics. 33: 2172-2172. DOI: 10.1118/1.2241460 |
0.476 |
|
2006 |
Yoon S, Henry R, Bouley D, Fahrig R. SU‐FF‐I‐07: Characterization of a Novel Anthropomorphic Plastinated Lung Phantom Medical Physics. 33: 1998-1998. DOI: 10.1118/1.2240245 |
0.622 |
|
2005 |
Wen Z, Fahrig R, Pelc NJ. Robust x-ray tubes for use within magnetic fields of MR scanners. Medical Physics. 32: 2327-2336. PMID 28493583 DOI: 10.1118/1.1944267 |
0.362 |
|
2005 |
Ramamurthi K, Strobel N, Fahrig R, Prince JL. Fully truncated cone-beam reconstruction on Pi lines using prior CT. Medical Image Computing and Computer-Assisted Intervention : Miccai ... International Conference On Medical Image Computing and Computer-Assisted Intervention. 8: 631-8. PMID 16685899 |
0.326 |
|
2005 |
Schmidt TG, Fahrig R, Pelc NJ. A three-dimensional reconstruction algorithm for an inverse-geometry volumetric CT system. Medical Physics. 32: 3234-45. PMID 16370414 DOI: 10.1118/1.2064827 |
0.422 |
|
2005 |
Ganguly A, Wen Z, Daniel BL, Butts K, Kee ST, Rieke V, Do HM, Pelc NJ, Fahrig R. Truly hybrid X-ray/MR imaging: toward a streamlined clinical system. Academic Radiology. 12: 1167-77. PMID 16099685 DOI: 10.1016/J.Acra.2005.03.076 |
0.391 |
|
2005 |
Yu H, Fahrig R, Pelc NJ. Co-registration of x-ray and MR fields of view in a hybrid XMR system. Journal of Magnetic Resonance Imaging : Jmri. 22: 291-301. PMID 16028248 DOI: 10.1002/Jmri.20376 |
0.38 |
|
2005 |
Fahrig R, Wen Z, Ganguly A, DeCrescenzo G, Rowlands JA, Stevens GM, Saunders RF, Pelc NJ. Performance of a static-anode/flat-panel x-ray fluoroscopy system in a diagnostic strength magnetic field: a truly hybrid x-ray/MR imaging system. Medical Physics. 32: 1775-84. PMID 16013735 DOI: 10.1118/1.1915016 |
0.412 |
|
2005 |
Rieke V, Ganguly A, Daniel BL, Scott G, Pauly JM, Fahrig R, Pelc NJ, Butts K. X-ray compatible radiofrequency coil for magnetic resonance imaging. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 53: 1409-14. PMID 15906285 DOI: 10.1002/Mrm.20494 |
0.402 |
|
2005 |
Holdsworth DW, Pollmann SI, Nikolov HN, Fahrig R. Correction of XRII geometric distortion using a liquid-filled grid and image subtraction. Medical Physics. 32: 55-64. PMID 15719955 DOI: 10.1118/1.1827751 |
0.63 |
|
2005 |
Schmidt TG, Fahrig R, Pelc NJ, Solomon EG. Reply to “Comment on ‘An inverse-geometry volumetric CT system with a large-area scanned source: A feasibility study’ '' [Med. Phys. 32, 635 (2005)] Medical Physics. 32: 636-636. DOI: 10.1118/1.1851913 |
0.36 |
|
2004 |
Schmidt TG, Fahrig R, Pelc NJ, Solomon EG. An inverse-geometry volumetric CT system with a large-area scanned source: a feasibility study. Medical Physics. 31: 2623-7. PMID 15487745 DOI: 10.1118/1.1786171 |
0.389 |
|
2004 |
Fahrig R, Ganguly A, Starman JD, Strobel N. C-arm CT with XRIIs and digital flat panels: A review Proceedings of Spie - the International Society For Optical Engineering. 5535: 400-409. DOI: 10.1117/12.561147 |
0.414 |
|
2003 |
Fahrig R, Heit G, Wen Z, Daniel BL, Butts K, Pelc NJ. First use of a truly-hybrid X-ray/MR imaging system for guidance of brain biopsy. Acta Neurochirurgica. 145: 995-7; discussion 99. PMID 14628205 DOI: 10.1007/S00701-003-0138-7 |
0.449 |
|
2003 |
Fahrig R, Pineda AR, Solomon EG, Leung AN, Pelc NJ. Fast tomosynthesis for lung cancer detection using the SBDX geometry Proceedings of Spie - the International Society For Optical Engineering. 5030: 371-378. DOI: 10.1117/12.480149 |
0.323 |
|
2001 |
Fahrig R, Butts K, Wen Z, Saunders R, Kee ST, Sze DY, Daniel BL, Laerum F, Pelc NJ. Truly hybrid interventional MR/X-ray system: investigation of in vivo applications. Academic Radiology. 8: 1200-7. PMID 11770916 DOI: 10.1016/S1076-6332(03)80702-X |
0.324 |
|
2001 |
Stevens GM, Fahrig R, Pelc NJ. Filtered backprojection for modifying the impulse response of circular tomosynthesis. Medical Physics. 28: 372-80. PMID 11318319 DOI: 10.1118/1.1350588 |
0.342 |
|
2001 |
Fahrig R, Butts K, Rowlands JA, Saunders R, Stanton J, Stevens GM, Daniel BL, Wen Z, Ergun DL, Pelc NJ. A truly hybrid interventional MR/X-ray system: feasibility demonstration. Journal of Magnetic Resonance Imaging : Jmri. 13: 294-300. PMID 11169837 DOI: 10.1002/1522-2586(200102)13:2<294::Aid-Jmri1042>3.0.Co;2-X |
0.428 |
|
2000 |
Fahrig R, Holdsworth DW. Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities Medical Physics. 27: 30-38. PMID 10659735 DOI: 10.1118/1.598854 |
0.622 |
|
1999 |
Fahrig R, Nikolov H, Fox AJ, Holdsworth DW. A three-dimensional cerebrovascular flow phantom Medical Physics. 26: 1589-1599. PMID 10501059 DOI: 10.1118/1.598672 |
0.481 |
|
1997 |
Fahrig R, Moreau M, Holdsworth DW. Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: correction of image intensifier distortion. Medical Physics. 24: 1097-106. PMID 9243472 DOI: 10.1118/1.598013 |
0.647 |
|
1997 |
Fahrig R, Rowlands JA, Yaffe MJ. X-ray imaging with amorphous selenium: optimal spectra for digital mammography. Medical Physics. 23: 557-67. PMID 9157270 DOI: 10.1118/1.597688 |
0.31 |
|