Year |
Citation |
Score |
2022 |
Vöröslakos M, Kim K, Slager N, Ko E, Oh S, Parizi SS, Hendrix B, Seymour JP, Wise KD, Buzsáki G, Fernández-Ruiz A, Yoon E. HectoSTAR μLED Optoelectrodes for Large-Scale, High-Precision In Vivo Opto-Electrophysiology. Advanced Science (Weinheim, Baden-Wurttemberg, Germany). e2105414. PMID 35451232 DOI: 10.1002/advs.202105414 |
0.557 |
|
2020 |
Kim K, Vöröslakos M, Seymour JP, Wise KD, Buzsáki G, Yoon E. Artifact-free and high-temporal-resolution in vivo opto-electrophysiology with microLED optoelectrodes. Nature Communications. 11: 2063. PMID 32345971 DOI: 10.1038/S41467-020-15769-W |
0.591 |
|
2018 |
Kampasi K, English DF, Seymour J, Stark E, McKenzie S, Vöröslakos M, Buzsáki G, Wise KD, Yoon E. Dual color optogenetic control of neural populations using low-noise, multishank optoelectrodes. Microsystems & Nanoengineering. 4. PMID 30766759 DOI: 10.1038/S41378-018-0009-2 |
0.592 |
|
2017 |
Seymour JP, Wu F, Wise KD, Yoon E. State-of-the-art MEMS and microsystem tools for brain research. Microsystems & Nanoengineering. 3: 16066. PMID 31057845 DOI: 10.1038/Micronano.2016.66 |
0.534 |
|
2016 |
Kampasi K, Stark E, Seymour J, Na K, Winful HG, Buzsáki G, Wise KD, Yoon E. Fiberless multicolor neural optoelectrode for in vivo circuit analysis. Scientific Reports. 6: 30961. PMID 27485264 DOI: 10.1038/Srep30961 |
0.568 |
|
2015 |
Wu F, Stark E, Ku PC, Wise KD, Buzsáki G, Yoon E. Monolithically Integrated μLEDs on Silicon Neural Probes for High-Resolution Optogenetic Studies in Behaving Animals. Neuron. PMID 26627311 DOI: 10.1016/J.Neuron.2015.10.032 |
0.615 |
|
2015 |
Son Y, Jenny Lee H, Kim J, Shin H, Choi N, Justin Lee C, Yoon ES, Yoon E, Wise KD, Geun Kim T, Cho IJ. In vivo optical modulation of neural signals using monolithically integrated two-dimensional neural probe arrays. Scientific Reports. 5: 15466. PMID 26494437 DOI: 10.1038/Srep15466 |
0.613 |
|
2015 |
Kozai T, Catt K, Du Z, Kyounghwan N, Srivannavit O, Haque RU, Seymour J, Wise K, Yoon E, Cui X. Chronic in vivo evaluation of PEDOT/CNT for stable neural recordings. Ieee Transactions On Bio-Medical Engineering. PMID 26087481 DOI: 10.1109/Tbme.2015.2445713 |
0.582 |
|
2015 |
Buzsáki G, Stark E, Berényi A, Khodagholy D, Kipke DR, Yoon E, Wise KD. Tools for probing local circuits: high-density silicon probes combined with optogenetics. Neuron. 86: 92-105. PMID 25856489 DOI: 10.1016/J.Neuron.2015.01.028 |
0.547 |
|
2015 |
Kampasi K, Seymour J, Na K, Wise KD, Yoon E. Fiberless multicolor optoelectrodes using Injection Laser Diodes and Gradient-index lens coupled optical waveguides 2015 Transducers - 2015 18th International Conference On Solid-State Sensors, Actuators and Microsystems, Transducers 2015. 273-276. DOI: 10.1109/TRANSDUCERS.2015.7180914 |
0.456 |
|
2014 |
Johnson AC, Wise KD. An active thin-film cochlear electrode array with monolithic backing and curl Journal of Microelectromechanical Systems. 23: 428-437. DOI: 10.1109/Jmems.2013.2288947 |
0.653 |
|
2013 |
Wu F, Stark E, Im M, Cho IJ, Yoon ES, Buzsáki G, Wise KD, Yoon E. An implantable neural probe with monolithically integrated dielectric waveguide and recording electrodes for optogenetics applications. Journal of Neural Engineering. 10: 056012. PMID 23985803 DOI: 10.1088/1741-2560/10/5/056012 |
0.588 |
|
2013 |
Ghaed MH, Chen G, Haque RU, Wieckowski M, Kim Y, Kim G, Lee Y, Lee I, Fick D, Kim D, Seok M, Wise KD, Blaauw D, Sylvester D. Circuits for a cubic-millimeter energy-autonomous wireless intraocular pressure monitor Ieee Transactions On Circuits and Systems I: Regular Papers. 60: 3152-3162. DOI: 10.1109/Tcsi.2013.2265973 |
0.361 |
|
2013 |
Haque RUM, Wise KD. A glass-in-silicon reflow process for three-dimensional microsystems Journal of Microelectromechanical Systems. 22: 1470-1477. DOI: 10.1109/Jmems.2013.2265851 |
0.372 |
|
2012 |
Potkay JA, Wise KD. A hybrid thermopneumatic and electrostatic microvalve with integrated position sensing Micromachines. 3: 379-395. DOI: 10.3390/Mi3020379 |
0.719 |
|
2011 |
Im M, Cho IJ, Wu F, Wise KD, Yoon E. A dual-shank neural probe integrated with double waveguides on each shank for optogenetic applications. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2011: 5480-3. PMID 22255578 DOI: 10.1109/IEMBS.2011.6091398 |
0.557 |
|
2011 |
Liu J, Gupta NK, Wise KD, Gianchandani YB, Fan X. Demonstration of motionless Knudsen pump based micro-gas chromatography featuring micro-fabricated columns and on-column detectors. Lab On a Chip. 11: 3487-92. PMID 21869988 DOI: 10.1039/C1Lc20511K |
0.585 |
|
2011 |
Skousen JL, Merriam SM, Srivannavit O, Perlin G, Wise KD, Tresco PA. Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays. Progress in Brain Research. 194: 167-80. PMID 21867802 DOI: 10.1016/B978-0-444-53815-4.00009-1 |
0.356 |
|
2011 |
Kim SJ, Serrano G, Wise KD, Kurabayashi K, Zellers ET. Evaluation of a microfabricated thermal modulator for comprehensive two-dimensional microscale gas chromatography. Analytical Chemistry. 83: 5556-62. PMID 21696130 DOI: 10.1021/Ac200336E |
0.315 |
|
2011 |
Merriam ME, Dehmel S, Srivannavit O, Shore SE, Wise KD. A 3-d 160-site microelectrode array for cochlear nucleus mapping. Ieee Transactions On Bio-Medical Engineering. 58: 397-403. PMID 20959259 DOI: 10.1109/Tbme.2010.2088122 |
0.782 |
|
2011 |
Haque RM, Serrano DE, Gao X, N.-Shirazi A, Keesara V, Ayazi F, Wise KD. Hermetic packaging of resonators with vertical feedthroughs using a glass-in-silicon reflow process 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference, Transducers'11. 2303-2306. DOI: 10.1109/TRANSDUCERS.2011.5969539 |
0.471 |
|
2011 |
Merriam SME, Srivannavit O, Gulari MN, Wise KD. A three-dimensional 64-site folded electrode array using planar fabrication Journal of Microelectromechanical Systems. 20: 594-600. DOI: 10.1109/Jmems.2011.2127450 |
0.44 |
|
2011 |
Aarts AAA, Srivannavit O, Wise KD, Yoon E, Puers R, Van Hoof C, Neves HP. Fabrication technique of a compressible biocompatible interconnect using a thin film transfer process Journal of Micromechanics and Microengineering. 21. DOI: 10.1088/0960-1317/21/7/074012 |
0.546 |
|
2010 |
Perlin GE, Wise KD. An ultra compact integrated front end for wireless neural recording microsystems Journal of Microelectromechanical Systems. 19: 1409-1421. DOI: 10.1109/Jmems.2010.2082496 |
0.809 |
|
2009 |
Sodagar AM, Wise KD, Najafi K. A wireless implantable microsystem for multichannel neural recording Ieee Transactions On Microwave Theory and Techniques. 57: 2565-2573. DOI: 10.1109/Tmtt.2009.2029957 |
0.582 |
|
2009 |
Perlin GE, Wise KD. Ultra-compact integration for fully-implantable neural microsystems Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 228-231. DOI: 10.1109/MEMSYS.2009.4805360 |
0.785 |
|
2009 |
Perlin GE, Wise KD. Ultra-compact integration for fully-implantable neural microsystems Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 228-231. DOI: 10.1109/MEMSYS.2009.4805360 |
0.785 |
|
2009 |
Sodagar AM, Perlin GE, Yao Y, Najafi K, Wise KD. An implantable 64-channel wireless microsystem for single-unit neural recording Ieee Journal of Solid-State Circuits. 44: 2591-2604. DOI: 10.1109/Jssc.2009.2023159 |
0.792 |
|
2009 |
Wang J, Wise KD. A thin-film cochlear electrode array with integrated position sensing Journal of Microelectromechanical Systems. 18: 385-395. DOI: 10.1109/Jmems.2008.2011722 |
0.677 |
|
2008 |
Perlin GE, Wise KD. A compact architecture for three-dimensional neural microelectrode arrays. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2008: 5806-9. PMID 19164037 DOI: 10.1109/IEMBS.2008.4650534 |
0.795 |
|
2008 |
Perlin GE, Sodagar AM, Wise KD. A neural amplifier with high programmable gain and tunable bandwidth. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2008: 3154-7. PMID 19163376 DOI: 10.1109/IEMBS.2008.4649873 |
0.769 |
|
2008 |
Wise KD, Bhatti PT, Wang J, Friedrich CR. High-density cochlear implants with position sensing and control. Hearing Research. 242: 22-30. PMID 18495392 DOI: 10.1016/J.Heares.2008.04.002 |
0.782 |
|
2008 |
Wise KD, Sodagar AM, Yao Y, Gulari MN, Perlin GE, Najafi K. Microelectrodes, microelectronics, and implantable neural microsystems Proceedings of the Ieee. 96: 1184-1202. DOI: 10.1109/JPROC.2008.922564 |
0.778 |
|
2008 |
Wang J, Wise KD. A hybrid electrode array with built-in position sensors for an implantable MEMS-based cochlear prosthesis Journal of Microelectromechanical Systems. 17: 1187-1194. DOI: 10.1109/Jmems.2008.928705 |
0.676 |
|
2008 |
Albano F, Lin YS, Blaauw D, Sylvester DM, Wise KD, Sastry AM. A fully integrated microbattery for an implantable microelectromechanical system Journal of Power Sources. 185: 1524-1532. DOI: 10.1016/J.Jpowsour.2008.08.061 |
0.389 |
|
2007 |
Sodagar AM, Wise KD, Najafi K. A fully integrated mixed-signal neural processor for implantable multichannel cortical recording. Ieee Transactions On Bio-Medical Engineering. 54: 1075-88. PMID 17554826 DOI: 10.1109/Tbme.2007.894986 |
0.572 |
|
2007 |
Kim H, Steinecker WH, Reidy S, Lambertus GR, Astle AA, Najafi K, Zellers ET, Bernal LP, Washabaugh PD, Wise KD. A micropump-driven high-speed mems gas chromatography system Transducers and Eurosensors '07 - 4th International Conference On Solid-State Sensors, Actuators and Microsystems. 1505-1508. DOI: 10.1109/SENSOR.2007.4300430 |
0.57 |
|
2007 |
Kim H, Steinecker WH, Reidy S, Lambertus GR, Astle AA, Najafi K, Zellers ET, Bernal LP, Washabaugh PD, Wise KD. A micropump-driven high-speed mems gas chromatography system Transducers and Eurosensors '07 - 4th International Conference On Solid-State Sensors, Actuators and Microsystems. 1505-1508. DOI: 10.1109/SENSOR.2007.4300430 |
0.57 |
|
2007 |
Zellers ET, Reidy S, Veeneman RA, Gordenker R, Steinecker WH, Lambertus GR, Kim H, Potkay JA, Rowe MP, Zhong Q, Avery C, Chan HKL, Sacks RD, Najafi K, Wise KD. An integrated micro-analytical system for complex vapor mixtures Transducers and Eurosensors '07 - 4th International Conference On Solid-State Sensors, Actuators and Microsystems. 1491-1496. DOI: 10.1109/SENSOR.2007.4300427 |
0.751 |
|
2007 |
Sodagar AM, Perlin GE, Yao Y, Wise KD, Najafi K. An implantable microsystem for wireless multi-channel cortical recording Transducers and Eurosensors '07 - 4th International Conference On Solid-State Sensors, Actuators and Microsystems. 69-72. DOI: 10.1109/SENSOR.2007.4300073 |
0.78 |
|
2007 |
Mason A, Chavan AV, Wise KD. A mixed-voltage sensor readout circuit with on-chip calibration and built-in self-test Ieee Sensors Journal. 7: 1225-1232. DOI: 10.1109/Jsen.2007.897957 |
0.774 |
|
2007 |
Potkay JA, Lambertus GR, Sacks RD, Wise KD. A low-power pressure- and temperature-programmable micro gas chromatography column Journal of Microelectromechanical Systems. 16: 1071-1079. DOI: 10.1109/Jmems.2007.902470 |
0.692 |
|
2007 |
Yao Y, Gulari MN, Wiler JA, Wise KD. A microassembled low-profile three-dimensional microelectrode array for neural prosthesis applications Journal of Microelectromechanical Systems. 16: 977-988. DOI: 10.1109/Jmems.2007.896712 |
0.533 |
|
2007 |
Agah M, Wise KD. Low-mass PECVD oxynitride gas chromatographic columns Journal of Microelectromechanical Systems. 16: 853-860. DOI: 10.1109/Jmems.2007.893515 |
0.58 |
|
2007 |
Sodagar AM, Perlin GE, Ying Y, Najafi K, Wise KD. Chronic neural recording with a 64-channel cortical microsystem Proceedings of the 3rd International Ieee Embs Conference On Neural Engineering. 402-405. DOI: 10.1109/CNE.2007.369694 |
0.771 |
|
2007 |
Yao Y, Gulari MN, Casey B, Wiler JA, Wise KD. Silicon microelectrodes with flexible integrated cables for neural implant applications Proceedings of the 3rd International Ieee Embs Conference On Neural Engineering. 398-401. DOI: 10.1109/CNE.2007.369693 |
0.453 |
|
2007 |
Wise KD. Integrated sensors, MEMS, and microsystems: Reflections on a fantastic voyage Sensors and Actuators, a: Physical. 136: 39-50. DOI: 10.1016/J.Sna.2007.02.013 |
0.439 |
|
2007 |
Albano F, Chung MD, Blaauw D, Sylvester DM, Wise KD, Sastry AM. Design of an implantable power supply for an intraocular sensor, using POWER (power optimization for wireless energy requirements) Journal of Power Sources. 170: 216-224. DOI: 10.1016/J.Jpowsour.2007.04.007 |
0.323 |
|
2006 |
Yao Y, Gulari MN, Wise KD. Microassembly techniques for a three-dimensional neural stimulating microelectrode array. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 4643-6. PMID 17947106 DOI: 10.1109/IEMBS.2006.260836 |
0.434 |
|
2006 |
Perlin GE, Sodagar AM, Wise KD. Neural recording front-end designs for fully implantable neuroscience applications and neural prosthetic microsystems. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 2982-5. PMID 17946997 DOI: 10.1109/IEMBS.2006.260193 |
0.8 |
|
2006 |
Sodagar AM, Wise KD, Najafi K. A neural signal processor for an implantable multi-channel cortical recording microsystem. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 5900-3. PMID 17946726 DOI: 10.1109/IEMBS.2006.259285 |
0.496 |
|
2006 |
Wang J, Gulari MN, Wise KD. A parylene-silicon cochlear electrode array with integrated position sensors. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 3170-3. PMID 17946554 DOI: 10.1109/IEMBS.2006.260604 |
0.64 |
|
2006 |
Sodagar AM, Wise KD, Najafi K. Generic controller dedicated to telemetry-controlled microsystems. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 1: 2075-8. PMID 17946493 DOI: 10.1109/IEMBS.2006.259286 |
0.42 |
|
2006 |
Lemmerhirt DF, Staudacher EM, Wise KD. A multitransducer microsystem for insect monitoring and control. Ieee Transactions On Bio-Medical Engineering. 53: 2084-91. PMID 17019873 DOI: 10.1109/Tbme.2006.877115 |
0.771 |
|
2006 |
Tang Y, Aslam DM, Wang J, Wise KD. New design of the cochlear implant probe with polycrystalline diamond piezoresistive position sensors Proceedings of 1st Ieee International Conference On Nano Micro Engineered and Molecular Systems, 1st Ieee-Nems. 1129-1132. DOI: 10.1109/NEMS.2006.334647 |
0.584 |
|
2006 |
Bhatti PT, Wise KD. A 32-site 4-channel high-density electrode array for a cochlear prosthesis Ieee Journal of Solid-State Circuits. 41: 2965-2973. DOI: 10.1109/Jssc.2006.884862 |
0.701 |
|
2006 |
Lemmerhirt DF, Wise KD. Chip-scale integration of data-gathering microsystems Proceedings of the Ieee. 94: 1138-1158. DOI: 10.1109/JPROC.2006.873619 |
0.738 |
|
2006 |
Takahata K, Gianchandani YB, Wise KD. Micromachined antenna stents and cuffs for monitoring intraluminal pressure and flow Journal of Microelectromechanical Systems. 15: 1289-1298. DOI: 10.1109/Jmems.2006.880229 |
0.573 |
|
2006 |
Agah M, Lambertus GR, Sacks R, Wise K. High-speed MEMS-based gas chromatography Journal of Microelectromechanical Systems. 15: 1371-1378. DOI: 10.1109/JMEMS.2006.879708 |
0.477 |
|
2006 |
DeHennis AD, Wise KD. A fully integrated multisite pressure sensor for wireless arterial flow characterization Journal of Microelectromechanical Systems. 15: 678-685. DOI: 10.1109/Jmems.2006.876668 |
0.785 |
|
2006 |
Papageorgiou DP, Shore SE, Bledsoe SC, Wise KD. A shuttered neural probe with on-chip flowmeters for chronic in vivo drug delivery Journal of Microelectromechanical Systems. 15: 1025-1033. DOI: 10.1109/Jmems.2005.863733 |
0.774 |
|
2006 |
Sodagar AM, Najafi K, Wise KD, Ghovanloo M. Fully-integrated CMOS power regulator for telemetry-powered implantable biomedical microsystems Proceedings of the Custom Integrated Circuits Conference. 659-662. DOI: 10.1109/CICC.2006.320862 |
0.615 |
|
2006 |
Sodagar AM, Najafi K, Wise KD, Ghovanloo M. Fully-integrated CMOS power regulator for telemetry-powered implantable biomedical microsystems Proceedings of the Custom Integrated Circuits Conference. 659-662. DOI: 10.1109/CICC.2006.320862 |
0.615 |
|
2006 |
Yao Y, Gulari MN, Wiler JA, Wise KD. Active silicon stimulating microelectrodes and their use in the central auditory system Ieee 2006 Biomedical Circuits and Systems Conference Healthcare Technology, Biocas 2006. 178-181. DOI: 10.1109/BIOCAS.2006.4600337 |
0.366 |
|
2006 |
Sodagar AM, Wise KD, Najafi K. A fully-integrated mixed-signal neural processing module for implantable multi-channel cortical recording Ieee 2006 Biomedical Circuits and Systems Conference Healthcare Technology, Biocas 2006. 37-40. DOI: 10.1109/BIOCAS.2006.4600302 |
0.515 |
|
2006 |
Sodagar AM, Wise KD, Najafi K. An interface chip for power and bidirectional data telemetry in an implantable cochlear microsystem Ieee 2006 Biomedical Circuits and Systems Conference Healthcare Technology, Biocas 2006. 1-4. DOI: 10.1109/BIOCAS.2006.4600293 |
0.485 |
|
2006 |
Tang Y, Aslam DM, Wang J, Wise KD. Study of polycrystalline diamond piezoresistive position sensors for application in cochlear implant probe Diamond and Related Materials. 15: 199-202. DOI: 10.1016/J.Diamond.2005.06.018 |
0.628 |
|
2006 |
Bhatti PT, Lee S, Wise KD. A 32-site 4-channel cochlear electrode array Digest of Technical Papers - Ieee International Solid-State Circuits Conference. 50+44. |
0.646 |
|
2006 |
McAfee L, Najafi K, Gianchandani Y, Wise KD, Maharbiz MM, Aslam D, Bergstrom P, Friedrich C. MEMS and microsystems courses with national and international dissemination Asee Annual Conference and Exposition, Conference Proceedings. |
0.391 |
|
2006 |
Kim H, Steinecker WH, Lambertus GR, Astle AA, Najafi K, Zellers ET, Bernal LP, Washabaugh PD, Wise KD. Integrated high-pressure 4-stage micropump for high-speed micro gas chromatography Micro Total Analysis Systems - Proceedings of Microtas 2006 Conference: 10th International Conference On Miniaturized Systems For Chemistry and Life Sciences. 1037-1039. |
0.473 |
|
2005 |
Yao Y, Gulari MN, Ghimire S, Hetke JF, Wise KD. A low-profile three-dimensional silicon/parylene stimulating electrode array for neural prosthesis applications. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2: 1293-6. PMID 17282432 DOI: 10.1109/IEMBS.2005.1616663 |
0.486 |
|
2005 |
Wise KD. Silicon microsystems for neuroscience and neural prostheses. Ieee Engineering in Medicine and Biology Magazine : the Quarterly Magazine of the Engineering in Medicine & Biology Society. 24: 22-9. PMID 16248114 DOI: 10.1109/Memb.2005.1511497 |
0.394 |
|
2005 |
Lu CJ, Steinecker WH, Tian WC, Oborny MC, Nichols JM, Agah M, Potkay JA, Chan HK, Driscoll J, Sacks RD, Wise KD, Pang SW, Zellers ET. First-generation hybrid MEMS gas chromatograph. Lab On a Chip. 5: 1123-31. PMID 16175269 DOI: 10.1039/B508596A |
0.782 |
|
2005 |
Olsson RH, Buhl DL, Sirota AM, Buzsaki G, Wise KD. Band-tunable and multiplexed integrated circuits for simultaneous recording and stimulation with microelectrode arrays. Ieee Transactions On Bio-Medical Engineering. 52: 1303-11. PMID 16041994 DOI: 10.1109/Tbme.2005.847540 |
0.67 |
|
2005 |
Wang J, Gulari M, Bhatti PT, Arcand BY, Beach K, Friedrich CR, Wise KD. A cochlear electrode array with built-in position sensing Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 786-789. DOI: 10.1109/MEMSYS.2005.1454047 |
0.648 |
|
2005 |
Agah M, Wise KD. A fully-dry pecvd-oxynitride process for microgc column fabrication Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 774-777. DOI: 10.1109/MEMSYS.2005.1454044 |
0.5 |
|
2005 |
Olsson RH, Wise KD. A three-dimensional neural recording microsystem with implantable data compression circuitry Ieee Journal of Solid-State Circuits. 40: 2796-2804. DOI: 10.1109/JSSC.2005.858479 |
0.591 |
|
2005 |
Agah M, Potkay JA, Lambertus G, Sacks R, Wise KD. High-performance temperature-programmed microfabricated gas chromatography columns Journal of Microelectromechanical Systems. 14: 1039-1050. DOI: 10.1109/Jmems.2005.856648 |
0.776 |
|
2005 |
DeHennis AD, Wise KD. A wireless microsystem for the remote sensing of pressure, temperature, and relative humidity Journal of Microelectromechanical Systems. 14: 12-22. DOI: 10.1109/Jmems.2004.839650 |
0.789 |
|
2005 |
Agah M, Wise KD. PECVD-oxynitride gas chromatographic columns Technical Digest - International Electron Devices Meeting, Iedm. 2005: 302-305. |
0.461 |
|
2005 |
Lemmerhirt DF, Fick DA, Wise KD. An autonomous microsystem for environmental and biological data gathering Digest of Technical Papers - International Conference On Solid State Sensors and Actuators and Microsystems, Transducers '05. 1: 233-238. |
0.713 |
|
2005 |
Potkay JA, Wise KD. An electrostatically latching thermopneumatic microvalve with closed-loop position sensing Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 415-418. |
0.645 |
|
2004 |
Lambertus G, Elstro A, Sensenig K, Potkay J, Agah M, Scheuering S, Wise K, Dorman F, Sacks R. Design, fabrication, and evaluation of microfabricated columns for gas chromatography. Analytical Chemistry. 76: 2629-37. PMID 15117208 DOI: 10.1021/Ac030367X |
0.752 |
|
2004 |
Agah M, Lambertus GR, Sacks RD, Wise KD. High-speed MEMS-based gas chromatography Technical Digest - International Electron Devices Meeting, Iedm. 27-30. DOI: 10.1109/Jmems.2006.879708 |
0.608 |
|
2004 |
Arcand BY, Bhatti PT, Butala NV, Wang J, Friedrich CR, Wise KD. Active positioning device for a perimodiolar cochlear electrode array Microsystem Technologies. 10: 478-483. DOI: 10.1007/S00542-004-0376-5 |
0.776 |
|
2004 |
Perlin GE, Wise KD. The effect of the substrate on the extracellular neural activity recorded with micromachined silicon microprobes Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 26: 2002-2005. |
0.773 |
|
2004 |
Takahata K, DeHennis A, Wise KD, Gianchandani YB. A wireless microsensor for monitoring flow and pressure in a blood vessel utilizing A dual-inductor antenna stent and two pressure sensors Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 216-219. |
0.743 |
|
2003 |
Csicsvari J, Henze DA, Jamieson B, Harris KD, Sirota A, Barthó P, Wise KD, Buzsáki G. Massively parallel recording of unit and local field potentials with silicon-based electrodes. Journal of Neurophysiology. 90: 1314-23. PMID 12904510 DOI: 10.1152/Jn.00116.2003 |
0.709 |
|
2003 |
Csicsvari J, Jamieson B, Wise KD, Buzsáki G. Mechanisms of gamma oscillations in the hippocampus of the behaving rat. Neuron. 37: 311-22. PMID 12546825 DOI: 10.1016/S0896-6273(02)01169-8 |
0.658 |
|
2003 |
DeHennis A, Wise KD. An all-capacitive sensing chip for temperature, absolute pressure, and relative humidity Transducers 2003 - 12th International Conference On Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers. 2: 1860-1863. DOI: 10.1109/SENSOR.2003.1217151 |
0.746 |
|
2003 |
Bhatti PT, Arcand BY, Wang J, Butala NV, Friedrich CR, Wise KD. A high-density electrode array for a cochlear prosthesis Transducers 2003 - 12th International Conference On Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers. 2: 1750-1753. DOI: 10.1109/SENSOR.2003.1217124 |
0.738 |
|
2003 |
Agah M, Potkay JA, Driscoll JA, Sacks RD, Kaviany M, Wise KD. Thermal behavior of high-performance temperature programmed microfabricated gas chromatography columns Transducers 2003 - 12th International Conference On Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers. 2: 1339-1342. DOI: 10.1109/SENSOR.2003.1217021 |
0.711 |
|
2003 |
Yao Y, Gulari MN, Hetke JF, Wise KD. A self-testing multiplexed CMOS stimulating probe for a 1024-site neural prosthesis Transducers 2003 - 12th International Conference On Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers. 2: 1213-1216. DOI: 10.1109/SENSOR.2003.1216990 |
0.367 |
|
2003 |
Lemmerhirt DF, Wise KD. Air-isolated through-wafer interconnects for microsystem applications Transducers 2003 - 12th International Conference On Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers. 2: 1067-1070. DOI: 10.1109/SENSOR.2003.1216953 |
0.726 |
|
2003 |
Rich CA, Wise KD. A high-flow thermopneumatic microvalve with improved efficiency and integrated state sensing Journal of Microelectromechanical Systems. 12: 201-208. DOI: 10.1109/Jmems.2002.808459 |
0.745 |
|
2003 |
Olsson RH, Gulari MN, Wise KD. A fully-integrated bandpass amplifier for extracellular neural recording International Ieee/Embs Conference On Neural Engineering, Ner. 2003: 165-168. DOI: 10.1109/CNE.2003.1196783 |
0.603 |
|
2003 |
Ghovanloo M, Wise KD, Najafi K. Towards a button-sized 1024-site wireless cortical microstimulating array International Ieee/Embs Conference On Neural Engineering, Ner. 2003: 138-141. DOI: 10.1109/CNE.2003.1196776 |
0.46 |
|
2003 |
Takahata K, DeHennis A, Wise KD, Gianchandani YB. Stentenna: A Micromachined Antenna Stent for Wireless Monitoring of Implantable Microsensors Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 4: 3360-3363. |
0.737 |
|
2003 |
Vetter RJ, Olsson RH, Hetke JF, Williams JC, Pellinen D, Wise KD, Kipke DR. Silicon-substrate Intracortical Microelectrode Arrays with Integrated Electronics for Chronic Cortical Recording Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 3: 2164-2167. |
0.598 |
|
2003 |
Olsson RH, Buhl DL, Gulari MN, Buzsaki G, Wise KD. A Silicon Microelectrode Array for Simultaneous Recording and Stimulation in the Brain of Behaving Animals Annual International Conference of the Ieee Engineering in Medicine and Biology - Proceedings. 2: 1968-1971. |
0.587 |
|
2003 |
Potkay JA, Driscoll JA, Agah M, Sacks RD, Wise KD. A high-performance microfabricated gas chromatography column Proceedings of the Ieee Micro Electro Mechanical Systems (Mems). 395-398. |
0.714 |
|
2002 |
Chavan AV, Wise KD. A monolithic fully-integrated vacuum-sealed CMOS pressure sensor Ieee Transactions On Electron Devices. 49: 164-169. DOI: 10.1109/16.974763 |
0.794 |
|
2002 |
Lemmerhirt DF, Wise KD. Field-operable microconnections using automatically-triggered localized solder-bonding Proceedings of the Ieee Micro Electro Mechanical Systems (Mems). 403-406. |
0.709 |
|
2002 |
DeHennis A, Wise KD. A double-sided single-chip wireless pressure sensor Proceedings of the Ieee Micro Electro Mechanical Systems (Mems). 252-255. |
0.754 |
|
2001 |
Bai Q, Wise KD. Single-unit neural recording with active microelectrode arrays. Ieee Transactions On Bio-Medical Engineering. 48: 911-20. PMID 11499528 DOI: 10.1109/10.936367 |
0.353 |
|
2001 |
Chavan AV, Wise KD. Batch-processed vacuum-sealed capacitive pressure sensors Journal of Microelectromechanical Systems. 10: 580-588. DOI: 10.1109/84.967381 |
0.78 |
|
2000 |
Bai Q, Wise KD, Anderson DJ. A high-yield microassembly structure for three-dimensional microelectrode arrays. Ieee Transactions On Bio-Medical Engineering. 47: 281-9. PMID 10743769 DOI: 10.1109/10.827288 |
0.388 |
|
2000 |
Kang U, Wise KD. A high-speed capacitive humidity sensor with on-chip thermal reset Ieee Transactions On Electron Devices. 47: 702-710. DOI: 10.1109/16.830983 |
0.347 |
|
2000 |
Yazdi N, Mason A, Najafi K, Wise KD. Generic interface chip for capacitive sensors in low-power multi-parameter microsystems Sensors and Actuators, a: Physical. 84: 351-361. DOI: 10.1016/S0924-4247(00)00307-1 |
0.568 |
|
2000 |
Chavan AV, Wise KD. Monolithic fully-integrated vacuum-sealed CMOS pressure sensor Proceedings of the Ieee Micro Electro Mechanical Systems (Mems). 341-346. |
0.768 |
|
1999 |
Oliver AD, Wise KD. 1024-Element bulk-micromachined thermopile infrared imaging array Sensors and Actuators, a: Physical. 73: 222-231. DOI: 10.1016/S0924-4247(98)00276-3 |
0.332 |
|
1999 |
Rich CA, Wise KD. 8-Bit microflow controller using pneumatically-actuated microvalves Proceedings of the Ieee Micro Electro Mechanical Systems (Mems). 130-134. |
0.68 |
|
1998 |
Bell TE, Wise KD, Anderson DJ. A flexible micromachined electrode array for a cochlear prosthesis Sensors and Actuators a: Physical. 66: 63-69. DOI: 10.1109/Sensor.1997.635478 |
0.412 |
|
1998 |
Rich CA, Wise KD. A self-controlled microcontrolled microvalve Characterization and Metrology For Ulsi Technology. 449: 937-941. DOI: 10.1063/1.56891 |
0.361 |
|
1998 |
Robertson JK, Wise KD. A low pressure micromachined flow modulator Sensors and Actuators, a: Physical. 71: 98-106. DOI: 10.1016/S0924-4247(98)00160-5 |
0.361 |
|
1997 |
Chen J, Wise KD. A silicon probe with integrated microheaters for thermal marking and monitoring of neural tissue. Ieee Transactions On Bio-Medical Engineering. 44: 770-4. PMID 9254990 DOI: 10.1109/10.605437 |
0.309 |
|
1997 |
Chen J, Wise KD, Hetke JF, Bledsoe SC. A multichannel neural probe for selective chemical delivery at the cellular level. Ieee Transactions On Bio-Medical Engineering. 44: 760-9. PMID 9254989 DOI: 10.1109/10.605435 |
0.36 |
|
1997 |
Souza RJD, Wise KD. A very high density bulk micromachined capacitive tactile imager Sensors. 2: 1473-1476. DOI: 10.1109/Sensor.1997.635743 |
0.325 |
|
1997 |
Chavan AV, Wise KD. A batch-processed vacuum-sealed capacitive pressure sensor Sensors. 2: 1449-1452. DOI: 10.1109/Sensor.1997.635737 |
0.787 |
|
1997 |
Kim J, Wise KD. A micromachined sensor for in-situ polymer buildup monitoring in reactive ion etching systems Sensors. 2: 1295-1298. DOI: 10.1109/Sensor.1997.635473 |
0.333 |
|
1997 |
Kim C, Wise KD. Low-voltage electronics for the stimulation of biological neural networks using fully complementary BiCMOS circuits Ieee Journal of Solid-State Circuits. 32: 1483-1490. DOI: 10.1109/4.634656 |
0.322 |
|
1997 |
Chen J, Wise KD. A high-resolution silicon monolithic nozzle array for inkjet printing Ieee Transactions On Electron Devices. 44: 1401-1409. DOI: 10.1109/16.622594 |
0.382 |
|
1997 |
Bergstrom PL, Patel SV, Schwank JW, Wise KD. A micromachined surface work-function gas sensor for low-pressure oxygen detection Sensors and Actuators, B: Chemical. 42: 195-204. DOI: 10.1016/S0925-4005(97)80336-X |
0.342 |
|
1996 |
Kim C, Wise KD. A 64-site multishank CMOS low-profile neural stimulating probe Ieee Journal of Solid-State Circuits. 31: 1230-1238. DOI: 10.1109/4.535406 |
0.373 |
|
1996 |
Majoo S, Gland JL, Wise KD, Schwank JW. A silicon micromachined conductometric gas sensor with a maskless Pt sensing film deposited by selected-area CVD Sensors and Actuators, B: Chemical. 36: 312-319. DOI: 10.1016/S0925-4005(97)80088-3 |
0.307 |
|
1995 |
Wise KD. MICROMACHINES, MEMS, AND MICROSYSTEMS Ieej Transactions On Sensors and Micromachines. 115: 5-6. DOI: 10.1541/Ieejsmas.115.5 |
0.337 |
|
1995 |
Baer WG, Najafi K, Wise KD, Toth RS. A 32-element micromachined thermal imager with on-chip multiplexing Sensors and Actuators: a. Physical. 48: 47-54. DOI: 10.1016/0924-4247(95)00980-9 |
0.544 |
|
1994 |
Hetke JF, Lund JL, Najafi K, Wise KD, Anderson DJ. Silicon ribbon cables for chronically implantable microelectrode arrays. Ieee Transactions On Bio-Medical Engineering. 41: 314-21. PMID 8063297 DOI: 10.1109/10.284959 |
0.575 |
|
1994 |
Hoogerwerf AC, Wise KD. A three-dimensional microelectrode array for chronic neural recording. Ieee Transactions On Bio-Medical Engineering. 41: 1136-46. PMID 7851915 DOI: 10.1109/10.335862 |
0.386 |
|
1994 |
Kota S, Ananthasuresh GK, Crary SB, Wise KD. Design and fabrication of microelectromechanical systems Journal of Mechanical Design, Transactions of the Asme. 116: 1081-1088. DOI: 10.1115/1.2919490 |
0.364 |
|
1994 |
Zhang Y, Wise KD. Performance of NonPlanar Silicon Diaphragms under Large Deflections Journal of Microelectromechanical Systems. 3: 59-68. DOI: 10.1109/84.294322 |
0.312 |
|
1994 |
Najafi N, Wise KD, Schwank JW. A Micromachined Ultra-Thin-Film Gas Detector Ieee Transactions On Electron Devices. 41: 1770-1777. DOI: 10.1109/16.324587 |
0.342 |
|
1994 |
Yoon E, Wise KD. A Wideband Monolithic RMS-DC Converter Using Micromachined Diaphragm Structures Ieee Transactions On Electron Devices. 41: 1666-1668. DOI: 10.1109/16.310122 |
0.576 |
|
1994 |
Johnson CL, Schwank JW, Wise Kd. Integrated ultra-thin-film gas sensors Sensors and Actuators: B. Chemical. 20: 55-62. DOI: 10.1016/0925-4005(93)01162-W |
0.311 |
|
1994 |
Wolffenbuttel RF, Wise KD. Low-temperature silicon wafer-to-wafer bonding using gold at eutectic temperature Sensors and Actuators a-Physical. 43: 223-229. DOI: 10.1016/0924-4247(93)00653-L |
0.338 |
|
1993 |
Cho ST, Wise KD. A high-performance microflowmeter with built-in self test Sensors and Actuators: a. Physical. 36: 47-56. DOI: 10.1016/0924-4247(93)80140-C |
0.367 |
|
1992 |
Ji J, Wise KD. An implantable CMOS circuit interface for multiplexed microelectrode recording arrays Ieee Journal of Solid-State Circuits. 27: 433-443. DOI: 10.1109/4.121568 |
0.396 |
|
1992 |
Ji J, Cho S, Zhang Y, Najafi K, Wise K. An ultraminiature CMOS pressure sensor for a multiplexed cardiovascular catheter Ieee Transactions On Electron Devices. 39: 2260-2267. DOI: 10.1109/16.158797 |
0.573 |
|
1992 |
Yoon E, Wise KD. An Integrated Mass Flow Sensor with On-Chip CMOS Interface Circuitry Ieee Transactions On Electron Devices. 39: 1376-1386. DOI: 10.1109/16.137317 |
0.614 |
|
1992 |
Cho ST, Najafi K, Wise KD. Internal Stress Compensation and Scaling in Ultrasensitive Silicon Pressure Sensors Ieee Transactions On Electron Devices. 39: 836-842. DOI: 10.1109/16.127473 |
0.532 |
|
1992 |
Cho ST, Najafi K, Wise KD, Lowman CE. An Ultrasensitive Silicon Pressure-Based Microflow Sensor Ieee Transactions On Electron Devices. 39: 825-835. DOI: 10.1109/16.127472 |
0.577 |
|
1991 |
Ji J, Najafi K, Wise KD. A low-noise demultiplexing system for active multichannel microelectrode arrays. Ieee Transactions On Bio-Medical Engineering. 38: 75-81. PMID 2026435 DOI: 10.1109/10.68212 |
0.556 |
|
1991 |
Wise KD, Najafi K. Microfabrication techniques for integrated sensors and microsystems. Science (New York, N.Y.). 254: 1335-42. PMID 1962192 DOI: 10.1126/Science.1962192 |
0.561 |
|
1990 |
Najafi K, Ji J, Wise KD. Scaling limitations of silicon multichannel recording probes. Ieee Transactions On Bio-Medical Engineering. 37: 1-11. PMID 2303265 DOI: 10.1109/10.43605 |
0.558 |
|
1990 |
Najafi N, Wise KD. An organization and interface for sensor-driven semiconductor process control systems Ieee Transactions On Semiconductor Manufacturing. 3: 230-238. DOI: 10.1109/66.61972 |
0.345 |
|
1990 |
Tanghe S, Najafi K, Wise K. A planar IrO multichannel stimulating electrode for use in neural prostheses Sensors and Actuators B: Chemical. 1: 464-467. DOI: 10.1016/0925-4005(90)80250-4 |
0.578 |
|
1990 |
Hetke J, Najafi K, Wise K. Flexible miniature ribbon cables for long-term connection to implantable sensors Sensors and Actuators a: Physical. 23: 999-1002. DOI: 10.1016/0924-4247(90)87076-U |
0.575 |
|
1990 |
Suzuki K, Najafi K, Wise KD. Process alternatives and scaling limits for high-density silicon tactile imagers Sensors and Actuators a-Physical. 23: 915-918. DOI: 10.1016/0924-4247(90)87059-R |
0.533 |
|
1990 |
Crary SB, Baer WG, Cowles JC, Wise KD. Digital compensation of high-performance silicon pressure transducers Sensors and Actuators a-Physical. 21: 70-72. DOI: 10.1016/0924-4247(90)85014-U |
0.374 |
|
1990 |
Spangler LJ, Wise KD. A bulk silicon SOI process for active intevated sensor Sensors and Actuators a-Physical. 24: 117-122. DOI: 10.1016/0924-4247(90)80016-X |
0.344 |
|
1990 |
Ji J, Najafi K, Wise K. A scaled electronically-configurable multichannel recording array Sensors and Actuators a: Physical. 22: 589-591. DOI: 10.1016/0924-4247(89)80040-8 |
0.574 |
|
1989 |
Anderson DJ, Najafi K, Tanghe SJ, Evans DA, Levy KL, Hetke JF, Xue XL, Zappia JJ, Wise KD. Batch-fabricated thin-film electrodes for stimulation of the central auditory system. Ieee Transactions On Bio-Medical Engineering. 36: 693-704. PMID 2744793 DOI: 10.1109/10.32101 |
0.571 |
|
1989 |
Wise KD, Najafi K. VLSI Sensors in Medicine Vlsi Electronics Microstructure Science. 17: 213-246. DOI: 10.1016/B978-0-12-234117-5.50014-X |
0.546 |
|
1988 |
Drake KL, Wise KD, Farraye J, Anderson DJ, BeMent SL. Performance of planar multisite microprobes in recording extracellular single-unit intracortical activity. Ieee Transactions On Bio-Medical Engineering. 35: 719-32. PMID 3169824 DOI: 10.1109/10.7273 |
0.341 |
|
1988 |
Chau H, Wise KD. An ultraminiature solid-state pressure sensor for a cardiovascular catheter Ieee Transactions On Electron Devices. 35: 2355-2362. DOI: 10.1109/16.8814 |
0.39 |
|
1987 |
Chau H, Wise KD. Noise due to Brownian motion in ultrasensitive solid-state pressure sensors Ieee Transactions On Electron Devices. 34: 859-865. DOI: 10.1109/T-Ed.1987.23007 |
0.303 |
|
1987 |
Chau H, Wise KD. Scaling limits in batch-fabricated silicon pressure sensors Ieee Transactions On Electron Devices. 34: 850-858. DOI: 10.1109/T-Ed.1987.23006 |
0.348 |
|
1987 |
Spangler LJ, Wise KD. A technology for high-performance single-crystal silicon-on-insulator transistors Ieee Electron Device Letters. 8: 137-139. DOI: 10.1109/Edl.1987.26579 |
0.319 |
|
1986 |
BeMent SL, Wise KD, Anderson DJ, Najafi K, Drake KL. Solid-state electrodes for multichannel multiplexed intracortical neuronal recording. Ieee Transactions On Bio-Medical Engineering. 33: 230-41. PMID 3957372 DOI: 10.1109/Tbme.1986.325895 |
0.6 |
|
1986 |
Wise KD. The role of thin films in integrated solid-state sensors Journal of Vacuum Science and Technology a: Vacuum, Surfaces and Films. 4: 617-622. DOI: 10.1116/1.573844 |
0.375 |
|
1986 |
Choi IH, Wise KD. A silicon-thermopile-based infrared sensing array for use in automated manufacturing Ieee Transactions On Electron Devices. 33: 72-79. DOI: 10.1109/T-Ed.1986.22440 |
0.401 |
|
1985 |
Najafi K, Wise K, Mochizuki T. A high-yield IC-compatible multichannel recording array Ieee Transactions On Electron Devices. 32: 1206-1211. DOI: 10.1109/T-Ed.1985.22102 |
0.602 |
|
1985 |
Chun K, Wise KD. A high-performance silicon tactile imager based on a capacitive cell Ieee Transactions On Electron Devices. 32: 1196-1201. DOI: 10.1109/T-Ed.1985.22100 |
0.381 |
|
1984 |
Mochizuki T, Wise KD. An n-channel MOSFET with Schottky source and drain Ieee Electron Device Letters. 5: 108-111. DOI: 10.1109/Edl.1984.25850 |
0.309 |
|
1983 |
Kim S, Wise KD. Temperature sensitivity in silicon piezoresistive pressure transducers Ieee Transactions On Electron Devices. 30: 802-810. DOI: 10.1109/T-Ed.1983.21213 |
0.34 |
|
1982 |
Wise K. Formation of silicon microstructures for high performance integrated sensors Journal of the Acoustical Society of America. 72. DOI: 10.1121/1.2019980 |
0.433 |
|
1982 |
Lee YS, Wise KD. A batch-fabricated silicon capacitive pressure transducer with low temperature sensitivity Ieee Transactions On Electron Devices. 29: 42-48. DOI: 10.1109/T-Ed.1982.20656 |
0.331 |
|
1982 |
Lee KW, Wise KD. Sensim: A Simulation Program For Solid-State Pressure Sensors Ieee Transactions On Electron Devices. 29: 34-41. DOI: 10.1109/T-Ed.1982.20655 |
0.336 |
|
1982 |
Lahiji GR, Wise KD. A batch-fabricated silicon thermopile infrared detector Ieee Transactions On Electron Devices. 29: 14-22. DOI: 10.1109/T-Ed.1982.20652 |
0.362 |
|
1981 |
Jackson TN, Tischler MA, Wise KD. An electrochemical P-N junction etch-stop for the formation of silicon microstructures Ieee Electron Device Letters. 2: 44-45. DOI: 10.1109/Edl.1981.25334 |
0.311 |
|
1981 |
Wise KD. Integrated sensors: interfacing electronics to a non-electronic world Sensors and Actuators. 2: 229-237. DOI: 10.1016/0250-6874(81)80043-1 |
0.375 |
|
1980 |
Wise KD, Smart RB, Mancy KH. A transient current monitoring and electrode characterization system for a pulsed oxygen electrode Analytica Chimica Acta. 116: 297-305. DOI: 10.1016/S0003-2670(01)95209-2 |
0.308 |
|
1979 |
Pochay P, Wise KD, Allard LF, Rutledge LT. A multichannel depth probe fabricated using electron-beam lithography. Ieee Transactions On Bio-Medical Engineering. 26: 199-206. PMID 437800 DOI: 10.1109/Tbme.1979.326558 |
0.31 |
|
1979 |
Wise KD, Jackson TN, Masnari NA, Robinson MG, Solomon DE, Wuttke GH, Rensel WB. FABRICATION OF HEMISPHERICAL STRUCTURES USING SEMICONDUCTOR TECHNOLOGY FOR USE IN THERMONUCLEAR FUSION RESEARCH Journal of Vacuum Science &Amp; Technology. 16: 936-939. DOI: 10.1116/1.570116 |
0.303 |
|
1979 |
Borky JM, Wise KD. Integrated signal conditioning for silicon pressure sensors Ieee Transactions On Electron Devices. 26: 1906-1910. DOI: 10.1109/T-Ed.1979.19794 |
0.41 |
|
1979 |
Clark SK, Wise KD. Pressure sensitivity in anisotropically etched thin-diaphragm pressure sensors Ieee Transactions On Electron Devices. 26: 1887-1896. DOI: 10.1109/T-Ed.1979.19792 |
0.334 |
|
1979 |
Wolber WG, Wise KD. Sensor development in the microcomputer age Ieee Transactions On Electron Devices. 26: 1864-1874. DOI: 10.1109/T-Ed.1979.19789 |
0.332 |
|
1975 |
Wise KD, Angell JB. A low-capacitance multielectrode probe for use in extracellular neurophysiology. Ieee Transactions On Bio-Medical Engineering. 22: 212-9. PMID 1116854 DOI: 10.1109/Tbme.1975.324562 |
0.729 |
|
1974 |
Matsuo T, Wise KD. An Integrated Field-Effect Electrode for Biopotential Recording Ieee Transactions On Biomedical Engineering. 21: 485-487. DOI: 10.1109/Tbme.1974.324338 |
0.333 |
|
1973 |
Starr A, Wise KD, Csongradi J. An evaluation of photoengraved microelectrodes for extracellular single-unit recording. Ieee Transactions On Bio-Medical Engineering. 20: 291-3. PMID 4708764 DOI: 10.1109/Tbme.1973.324194 |
0.354 |
|
1973 |
Samaun, Wise KD, Angell JB. An IC piezoresistive pressure sensor for biomedical instrumentation. Ieee Transactions On Bio-Medical Engineering. 20: 101-9. PMID 4688300 DOI: 10.1109/Tbme.1973.324170 |
0.706 |
|
1970 |
Wise KD, Angell JB, Starr A. An integrated-circuit approach to extracellular microelectrodes. Ieee Transactions On Bio-Medical Engineering. 17: 238-47. PMID 5431636 DOI: 10.1109/Tbme.1970.4502738 |
0.732 |
|
Show low-probability matches. |