Year |
Citation |
Score |
2010 |
Li L, Preuss TM, Rilling JK, Hopkins WD, Glasser MF, Kumar B, Nana R, Zhang X, Hu X. Chimpanzee (Pan troglodytes) precentral corticospinal system asymmetry and handedness: a diffusion magnetic resonance imaging study. Plos One. 5: e12886. PMID 20877630 DOI: 10.1371/Journal.Pone.0012886 |
0.644 |
|
2010 |
Nana R, Hu X. Data consistency criterion for selecting parameters for k-space-based reconstruction in parallel imaging Magnetic Resonance Imaging. 28: 119-128. PMID 19570636 DOI: 10.1016/J.Mri.2009.05.047 |
0.683 |
|
2008 |
Nana R, Zhao T, Hu X. Single-shot multiecho parallel echo-planar imaging (EPI) for diffusion tensor imaging (DTI) with improved signal-to-noise ratio (SNR) and reduced distortion Magnetic Resonance in Medicine. 60: 1512-1517. PMID 19025894 DOI: 10.1002/Mrm.21770 |
0.678 |
|
2008 |
Nana R, Zhao T, Heberlein K, LaConte SM, Hu X. Cross-validation-based kernel support selection for improved GRAPPA reconstruction. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 59: 819-25. PMID 18383295 DOI: 10.1002/Mrm.21535 |
0.683 |
|
2008 |
Zhao T, Hu X. Iterative GRAPPA (iGRAPPA) for improved parallel imaging reconstruction. Magnetic Resonance in Medicine. 59: 903-7. PMID 18383282 DOI: 10.1002/Mrm.21370 |
0.372 |
|
2006 |
Kadah YM, Fahmy AS, Gabr RE, Heberlein K, Hu XP. Progressive magnetic resonance image reconstruction based on iterative solution of a sparse linear system. International Journal of Biomedical Imaging. 2006: 49378. PMID 23165034 DOI: 10.1155/Ijbi/2006/49378 |
0.326 |
|
2006 |
Ayyagari AL, Zhang X, Ghaghada KB, Annapragada A, Hu X, Bellamkonda RV. Long-circulating liposomal contrast agents for magnetic resonance imaging. Magnetic Resonance in Medicine. 55: 1023-9. PMID 16586449 DOI: 10.1002/Mrm.20846 |
0.307 |
|
2006 |
Heberlein K, Hu X. Auto-calibrated parallel spiral imaging Magnetic Resonance in Medicine. 55: 619-625. PMID 16453323 DOI: 10.1002/Mrm.20811 |
0.371 |
|
2004 |
Wang D, Heberlein K, LaConte S, Hu X. Inherent insensitivity to RF inhomogeneity in FLASH imaging. Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 52: 927-31. PMID 15389953 DOI: 10.1002/Mrm.20217 |
0.305 |
|
2002 |
Pfeuffer J, Van de Moortele PF, Ugurbil K, Hu X, Glover GH. Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging. Magnetic Resonance in Medicine. 47: 344-53. PMID 11810679 DOI: 10.1002/Mrm.10065 |
0.341 |
|
2001 |
Zhang X, Van De Moortele PF, Pfeuffer J, Hu X. Elimination of k-space spikes in fMRI data. Magnetic Resonance Imaging. 19: 1037-41. PMID 11595377 DOI: 10.1016/S0730-725X(01)00428-3 |
0.342 |
|
1999 |
Sarkar S, Heberlein K, Metzger GJ, Zhang X, Hu X. Applications of high-resolution echoplanar spectroscopic imaging for structural imaging Journal of Magnetic Resonance Imaging. 10: 1-7. PMID 10398971 DOI: 10.1002/(Sici)1522-2586(199907)10:1<1::Aid-Jmri1>3.0.Co;2-C |
0.321 |
|
1999 |
Metzger G, Sarkar S, Zhang X, Heberlein Maqbool Patel K, Hu X. A hybrid technique for spectroscopic imaging with reduced truncation artifact Magnetic Resonance Imaging. 17: 435-443. PMID 10195587 DOI: 10.1016/S0730-725X(98)00187-8 |
0.31 |
|
1997 |
Kadah YM, Hu X. Simulated phase evolution rewinding (SPHERE): a technique for reducing B0 inhomogeneity effects in MR images. Magnetic Resonance in Medicine. 38: 615-27. PMID 9324329 DOI: 10.1002/Mrm.1910380416 |
0.358 |
|
1996 |
Kim SG, Hu X, Adriany G, UÄŸurbil K. Fast interleaved echo-planar imaging with navigator: high resolution anatomic and functional images at 4 Tesla. Magnetic Resonance in Medicine. 35: 895-902. PMID 8744018 DOI: 10.1002/Mrm.1910350618 |
0.301 |
|
Show low-probability matches. |