Zhonglu Wang, Ph.D. - Publications

Affiliations: 
2006 Georgia Institute of Technology, Atlanta, GA 
Area:
Radiology, Radiation Physics, Radiation Chemistry

16 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2010 Wang Z, Howell RM, Burgett EA, Kry SF, Hertel NE, Salehpour M. Calibration of indium response functions in an Au-In-BSE system up to 800 MeV. Radiation Protection Dosimetry. 139: 565-73. PMID 20008907 DOI: 10.1093/Rpd/Ncp282  0.763
2009 Zhang SX, Gao J, Buchholz TA, Wang Z, Salehpour MR, Drezek RA, Yu TK. Quantifying tumor-selective radiation dose enhancements using gold nanoparticles: a monte carlo simulation study. Biomedical Microdevices. 11: 925-33. PMID 19381816 DOI: 10.1007/S10544-009-9309-5  0.3
2009 Kry SF, Price M, Wang Z, Mourtada F, Salehpour M. Investigation into the use of a MOSFET dosimeter as an implantable fiducial marker. Journal of Applied Clinical Medical Physics / American College of Medical Physics. 10: 2893. PMID 19223838 DOI: 10.1120/Jacmp.V10I1.2893  0.491
2009 Wang Z, Kry SF, Howell RM, Salehpour M. Comparison of Unfolding Methods for Determining Neutron Spectrum and Ambient Dose Equivalent Nuclear Technology. 168: 610-614. DOI: 10.13182/Nt09-A9277  0.64
2009 Wang Z, Howell RM, Kry SF, Burgett EA, Hertel NE, Salehpour M. Characterization of a gold-and-indium dual-activation-foil-based bonner sphere system Nuclear Technology. 168: 603-609. DOI: 10.13182/Nt09-A9276  0.752
2009 Howell RM, Burgett E, Hertel NE, Kry SF, Wang Z, Salehpour M. Measurement of high-energy neutron spectra with a bonner sphere extension system Nuclear Technology. 168: 333-339.  0.698
2008 Wang Z, Hutchinson JD, Hertel NE, Burgett E, Howell RM. Study of a gold-foil-based multisphere neutron spectrometer. Radiation Protection Dosimetry. 128: 289-93. PMID 17681965 DOI: 10.1093/Rpd/Ncm375  0.762
2008 Wang Z, Kry S, Burgett E, Howell R, Tailor R, Oliver J, Followill D, Smith A, Salehpour M. TH-D-AUD A-02: Measurement of Neutron Spectrum and Ambient Dose Equivalent Around a Mini-Phantom at a Proton Therapy Facility Medical Physics. 35: 2982-2982. DOI: 10.1118/1.2962894  0.735
2008 Kry S, Price M, Wang Z, Mourtada F, Salehpour M. SU-GG-T-275: Investigation Into the Use of a MOSFET Dosimeter as An Implantable Fiducial Marker Medical Physics. 35: 2788-2788. DOI: 10.1118/1.2962027  0.504
2007 Wang Z, Hertel NE, Lennox A. Calibration of the borated ion chamber at NIST reactor thermal column. Radiation Protection Dosimetry. 126: 626-30. PMID 17525059 DOI: 10.1093/Rpd/Ncm127  0.631
2006 Howell RM, Hertel NE, Wang Z, Hutchinson J, Fullerton GD. Calculation of effective dose from measurements of secondary neutron spectra and scattered photon dose from dynamic MLC IMRT for 6 MV, 15 MV, and 18 MV beam energies. Medical Physics. 33: 360-8. PMID 16532941 DOI: 10.1118/1.2140119  0.713
2006 Howell R, Kry S, Followill D, Hertel N, Wang Z, Salehpour M. WE-D-224C-04: Investigation of MLC Effects On Secondary Neutron Spectra for Varian, Siemens, and Elekta Medical Physics. 33: 2249-2250. DOI: 10.1118/1.2241783  0.764
2006 Howell RM, Hertel NE, Wang Z, Hutchinson J. RBE or effective dose to evaluate the effect of different beam energies for intensity modulated radiation therapy Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 562: 1024-1028. DOI: 10.1016/J.Nima.2006.02.087  0.668
2005 Wang Z, Hertel NE. Determination of dosimetric characteristics of OptiSeed(TM) a plastic brachytherapy (103)Pd source. Applied Radiation and Isotopes : Including Data, Instrumentation and Methods For Use in Agriculture, Industry and Medicine. 63: 311-21. PMID 15964196 DOI: 10.1016/J.Apradiso.2005.03.017  0.578
2005 Howell R, Hertel N, Wang Z, Fullerton G. MO-D-T-617-03: Secondary Neutron Spectra From High Energy IMRT and Conventional Treatment Plans Using Bonner Spheres and Au-197 Activation Foils Medical Physics. 32: 2060-2060. DOI: 10.1118/1.1998265  0.746
2004 Hertel NE, Shannon MP, Wang ZL, Valenzano MP, Mengesha W, Crowe RJ. Neutron measurements in the vicinity of a self-shielded PET cyclotron. Radiation Protection Dosimetry. 108: 255-61. PMID 15031447 DOI: 10.1093/rpd/nch026  0.595
Show low-probability matches.