Year |
Citation |
Score |
2022 |
Mace A, Gilbert JL. A mass balance analysis of the tribocorrosion process of titanium alloys using a single micro-asperity: Voltage and solution effects on plastic deformation, oxide repassivation, and ion dissolution. Journal of the Mechanical Behavior of Biomedical Materials. 136: 105531. PMID 36308875 DOI: 10.1016/j.jmbbm.2022.105531 |
0.311 |
|
2021 |
Smith SM, Gilbert JL. Interfacial compliance, energy dissipation, frequency effects, and long-term fretting corrosion performance of Ti-6Al-4V/CoCrMo interfaces. Journal of Biomedical Materials Research. Part A. PMID 34402604 DOI: 10.1002/jbm.a.37299 |
0.326 |
|
2021 |
Liu Y, Zhu D, Gilbert JL. Sub-nano to nanometer wear and tribocorrosion of titanium oxide-metal surfaces by in situ atomic force microscopy. Acta Biomaterialia. PMID 33812071 DOI: 10.1016/j.actbio.2021.03.049 |
0.3 |
|
2019 |
Pierre D, Swaminathan V, Scholl L, TenHuisen K, Gilbert JL. Effects of seating load magnitude and load orientation on seating mechanics in 5°40' mixed-alloy modular taper junctions. Journal of Biomechanics. 82: 251-258. PMID 30501911 DOI: 10.1016/J.Jbiomech.2018.10.037 |
0.519 |
|
2018 |
Scholl L, Pierre D, Rajaravivarma R, Lee R, Faizan A, Swaminathan V, TenHuisen K, Gilbert JL, Nevelos J. Effect of the support systems' compliance on total hip modular taper seating stability. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine. 232: 862-870. PMID 30238861 DOI: 10.1177/0954411918790282 |
0.519 |
|
2018 |
Pierre D, Swaminathan V, Scholl LY, TenHuisen K, Gilbert JL. Effects of Seating Load Magnitude on Incremental Cyclic Fretting Corrosion in 5°40' Mixed Alloy Modular Taper Junctions. The Journal of Arthroplasty. PMID 29486910 DOI: 10.1016/J.Arth.2018.01.039 |
0.545 |
|
2015 |
Gilbert JL, Mali SA, Sivan S. Corrosion of modular tapers in total joint replacements: A critical assessment of design, materials, surface structure, mechanics, electrochemistry, and biology Astm Special Technical Publication. 192-223. DOI: 10.1520/STP159120140135 |
0.342 |
|
2015 |
Gilbert JL, Wernle JD. Nano- and Microindentation Testing of UHMWPE Uhmwpe Biomaterials Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement and Medical Devices: Third Edition. 772-785. DOI: 10.1016/B978-0-323-35401-1.00040-5 |
0.724 |
|
2013 |
Swaminathan V, Gilbert JL. Potential and frequency effects on fretting corrosion of Ti6Al4V and CoCrMo surfaces. Journal of Biomedical Materials Research. Part A. 101: 2602-12. PMID 23404905 DOI: 10.1002/Jbm.A.34564 |
0.541 |
|
2012 |
Donohue ML, Swaminathan V, Gilbert JL, Fox CW, Smale J, Moquin RR, Calancie B. Intraoperative neuromonitoring: can the results of direct stimulation of titanium-alloy pedicle screws in the thoracic spine be trusted? Journal of Clinical Neurophysiology : Official Publication of the American Electroencephalographic Society. 29: 502-8. PMID 23207589 DOI: 10.1097/Wnp.0B013E3182767Aac |
0.519 |
|
2012 |
Swaminathan V, Gilbert JL. Fretting corrosion of CoCrMo and Ti6Al4V interfaces. Biomaterials. 33: 5487-503. PMID 22575833 DOI: 10.1016/J.Biomaterials.2012.04.015 |
0.573 |
|
2012 |
Swaminathan V, Zeng H, Lawrynowicz D, Zhang Z, Gilbert JL. Electrochemical investigation of chromium nanocarbide coated Ti-6Al-4V and Co-Cr-Mo alloy substrates Electrochimica Acta. 59: 387-397. DOI: 10.1016/J.Electacta.2011.10.085 |
0.527 |
|
2011 |
Swaminathan V, Zeng H, Lawrynowicz D, Zhang Z, Gilbert JL. Electrochemical investigation of chromium oxide-coated Ti-6Al-4V and Co-Cr-Mo alloy substrates. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. 98: 369-78. PMID 21648063 DOI: 10.1002/Jbm.B.31861 |
0.534 |
|
2010 |
Wernlé JD, Gilbert JL. Microscale and nanoscale surface strain mapping of single asperity wear in ultra high molecular weight polyethylene: Effects of materials, load, and asperity geometry. Journal of Biomedical Materials Research. Part A. 93: 1442-53. PMID 19927370 DOI: 10.1002/Jbm.A.32647 |
0.716 |
|
2009 |
Rodrigues DC, Urban RM, Jacobs JJ, Gilbert JL. In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. 88: 206-19. PMID 18683224 DOI: 10.1002/Jbm.B.31171 |
0.313 |
|
2009 |
Gilbert JL, Wernle JD. Nano-and Microindentation Testing of UHMWPE Uhmwpe Biomaterials Handbook. 497-509. DOI: 10.1016/B978-0-12-374721-1.00033-X |
0.733 |
|
2005 |
Wernlé JD, Gilbert JL. Micromechanics of shelf-aged and retrieved UHMWPE tibial inserts: indentation testing, oxidative profiling, and thickness effects. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. 75: 113-21. PMID 16034987 DOI: 10.1002/Jbm.B.30285 |
0.704 |
|
2005 |
Shim JB, Warner SJ, Hasenwinkel JM, Gilbert JL. Analysis of the shelf life of a two-solution bone cement. Biomaterials. 26: 4181-7. PMID 15664645 DOI: 10.1016/j.biomaterials.2004.10.027 |
0.378 |
|
2004 |
Gilbert JL, Merkhan I. Rate effects on the microindentation-based mechanical properties of oxidized, crosslinked, and highly crystalline ultrahigh-molecular-weight polyethylene. Journal of Biomedical Materials Research. Part A. 71: 549-58. PMID 15484205 DOI: 10.1002/jbm.a.30196 |
0.378 |
|
2004 |
Goldberg JR, Gilbert JL. The electrochemical and mechanical behavior of passivated and TiN/AlN-coated CoCrMo and Ti6Al4V alloys. Biomaterials. 25: 851-64. PMID 14609674 DOI: 10.1016/S0142-9612(03)00606-9 |
0.303 |
|
2003 |
Bearinger JP, Orme CA, Gilbert JL. Effect of hydrogen peroxide on titanium surfaces: in situ imaging and step-polarization impedance spectroscopy of commercially pure titanium and titanium, 6-aluminum, 4-vanadium. Journal of Biomedical Materials Research. Part A. 67: 702-12. PMID 14613216 DOI: 10.1002/jbm.a.10116 |
0.343 |
|
2003 |
Bearinger JP, Orme CA, Gilbert JL. In situ imaging and impedance measurements of titanium surfaces using AFM and SPIS. Biomaterials. 24: 1837-52. PMID 12615474 DOI: 10.1016/S0142-9612(02)00547-1 |
0.373 |
|
2002 |
Gilbert JL, Cumber J, Butterfield A. Surface micromechanics of ultrahigh molecular weight polyethylene: Microindentation testing, crosslinking, and material behavior. Journal of Biomedical Materials Research. 61: 270-81. PMID 12007208 DOI: 10.1002/jbm.10143 |
0.342 |
|
2001 |
Bearinger JP, Orme CA, Gilbert JL. Direct observation of hydration of TiO2 on Ti using electrochemical AFM: Freely corroding versus potentiostatically held Surface Science. 491: 370-387. DOI: 10.1016/S0039-6028(01)01300-0 |
0.348 |
|
1994 |
King AW, Lautenschlager E, Chai J, Gilbert J. A comparison of the hardness of different types of titanium and conventional metal ceramics. The Journal of Prosthetic Dentistry. 72: 314-9. PMID 7965906 DOI: 10.1016/0022-3913(94)90346-8 |
0.338 |
|
1994 |
Cheng AC, Chai JY, Gilbert J, Jameson LM. Investigation of stiffness and microstructure of joints soldered with gas-oxygen torch infrared methods The Journal of Prosthetic Dentistry. 72: 8-15. PMID 7916054 DOI: 10.1016/0022-3913(94)90208-9 |
0.31 |
|
1994 |
Shanbhag A, Jacobs J, Glant T, Gilbert J, Black J, Galante J. Composition and morphology of wear debris in failed uncemented total hip replacement Journal of Bone and Joint Surgery-British Volume. 76: 60-67. DOI: 10.1302/0301-620X.76B1.8300684 |
0.324 |
|
1993 |
Cheng AC, Chai JY, Gilbert J, Jameson LM. Mechanical properties of metal connectors soldered by gas torch versus an infrared technique Journal of Prosthodontics : Official Journal of the American College of Prosthodontists. 2: 103-109. PMID 7902170 DOI: 10.1111/J.1532-849X.1993.Tb00390.X |
0.357 |
|
1993 |
Gilbert JL, Piehler HR. On the nature and crystallographic orientation of subsurface cracks in high cycle fatigue of Ti-6Al-4V Metallurgical Transactions A. 24: 669-680. DOI: 10.1007/Bf02656635 |
0.655 |
|
1989 |
Gilbert JL, Piehler HR. Grain egression: A new mechanism of fatigue-crack initiation in Ti-6Al-4V Metallurgical Transactions A. 20: 1715-1725. DOI: 10.1007/Bf02663203 |
0.66 |
|
Show low-probability matches. |